THE MOST ADVANCED PULSED DYE LASER TECHNOLOGY
THE MOST TRUSTED PULSED DYE LASER IS ALSO THE MOST ADVANCED Candela’s Vbeam pulsed dye laser has a 20-year proven track ®
record of safety, reliability and efficacy for treatment of a wide range of vascular conditions. So how did we improve on the gold standard? Three ways: advanced technology; increased versatility; and simplified ease of use. At Candela, our pursuit of excellence means we never stop refining our products and services. The end result is effective treatments for your patients, backed by Candela’s unsurpassed training, marketing and service expertise.
Next Generation Technology, Unprecedented Product Versatility Candela’s gold standard Vbeam laser is better than ever thanks to cutting edge technology now available in three different configurations. One of them is right for your practice. Best of all, like all Candela products, our lasers are designed to grow with your practice. They are fully upgradeable, with training and service designed to keep pace with your changing needs.
OUR PATENTED PIGMENTED LESION
Compression Optic
Targeting Pigmentation
HANDPIECE** TARGETS AND ELIMINATES BROWN SPOTS AT THE EPIDERMIS LEVEL WITHOUT IMPACTING UNDERLYING BLOOD VESSELS CAUSING PURPURA.
Blood Moves Laterally
A DYNAMIC COOLING DEVICE SO ORIGINAL, IT’S PATENTED Candela’s patented Dynamic Cooling Device™ (DCD™) provides consistent, reproducible epidermal cooling and unparalleled comfort for your patients. DCD prepares skin for treatment by selectively cooling the upper layers with a burst of cryogen milliseconds before the laser pulse. DCD’s unique design provides the user with excellent visibility throughout the entire process. The most powerful benefits to you? Speed and Patient Safety. DCD is operator technique independent—it will provide the same epidermal protection no matter how fast the laser is fired. The more patients you see and treat optimally, the more profitable for your practice..
SUPPORT AFTER THE SALE Any laser purchase includes access to MyCandela.com, an exclusive marketing resource for your new laser. Services Include FREE Website Builder, Laser Marketing Tool Kits. Learning center and additional clinical information on the capabilities of your Candela laser.*
*Availability varies by country
FOR SKIN REJUVENATION
FOR SKIN REJUVENATION
AESTHETICA Aesthetica is specifically designed for skin rejuvenation; improving the consistency and color tone of the skin by removing both redness and pigmentation. It’s always been the industry’s gold standard for treating redness. Now, it is also effective at treating unwanted brown spots, including actual spot sizes
freckles, sun spots and uneven pigmentation. Our patented pigmented lesion handpiece* combined with Candela’s unique micro-pulse technology targets and eliminates brown areas at the epidermis level without impacting underlying blood vessels causing purpura. And Aesthetica is upgradeable to Platinum, to accommodate your growing, changing practice.
PRE AND POST-TREATMENT RESULTS
Brown Pigmentation
Facial Redness
Courtesy of Taro Kono, M.D.
Courtesy of Luigi L. Polla, M.D.
Brown Pigmentation
Angioma
Courtesy of Jerome M. Garden, M.D.
Courtesy of Thomas E. Rohrer, M.D.
Redesigned for Maximum Ease of Use Aesthetica has been designed for the ultimate
Vbeam AESTHETICA SPECIFICATIONS
ease of use. Each console is sleeker and smaller
Laser Type
Pulsed Dye
Wavelength
595 nm
Pulse
0.45-40 ms
technology for a user-friendly interface. Onscreen
Spot Sizes (diameter) with maximum energy
7 mm - 20 J/cm2 10 mm - 10 J/cm2 7 mm PL - 15 J/cm2 10 mm PL - 10 J/cm2
graphics are easy to read and provide clear,
Beam Delivery
Lens-coupled 3 m optical fiber with handpiece
than ever before for ease of maneuverability from treatment room to treatment room. Yet, it features a large 10” screen with touch-screen
simple-to-follow treatment guidelines.
Pulse Control
Fingerswitch, Footswitch
Dimensions
43" H x 16" W x 30" D** (109 cm x 40 cm x 76 cm)
Weight
290 lbs (132 kg)
Electrical
230 V 50/60 Hz, single phase, 18A
39" (99 cm) D with dye cartridge
**
DYNAMIC COOLING DEVICE Integrated controls, cryogen container and handpiece with distance gauge
LASER LIGHT AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED LIGHT CLASS 4 LASER PRODUCT (Per EN60825-1: 2002-07) MAXIMUM PULSE ENERGY 8J PULSE WIDTH .45–40 ms WAVELENGTH 595 nm
Complies with FDA performance standards for laser products except for deviations pursuant to laser Notice No. 50 dated July 26, 2002
AIMING BEAM — CLASS 1 MAXIMUM POWER 5mW PULSE WIDTH CW WAVELENGTH 520–550 nm
0123
** Patent pending. Specifications subject to change without notice. Vbeam is a registered trademark of Candela Corporation. Dynamic Cooling Device and DCD are trademarks. ©2005 Candela Corporation. All rights reserved. Printed in the USA. 11/05 0920-20-0055 Rev. 03
Cryogen
HFC 134a
DCD Spray Duration
User adjustable range: 20 - 100 ms
DCD Delay Duration
User adjustable range: 10 - 100 ms
Candela Corporation 530 Boston Post Road Wayland, MA 01778 USA Phone: (508) 358-7637 Fax: (508) 358-5569 Toll Free: (800) 821-2013 www.candelalaser.com
FOR ALL VASCULAR LESIONS FOR ALL VASCULAR LESIONS
PLATINUM Platinum treats a broad range of vascular lesions including facial and leg veins, rosacea, port wine stains, acne and much more. New micro-pulse technology means each laser pulse is actually made up of eight sub pulses, providing uniform and consistent vessel heating enabling improved clinical results without purpura.
PRE AND POST-TREATMENT RESULTS
Facial Veins
Leg Veins
Courtesy of Pablo Bioxeda, M.D.
Courtesy of Craig A. Trigueiro, M.D.
Port Wine Stain
Facial Redness
Courtesy of Elizabeth F. Rostan, M.D.
Courtesy of Eric Bernstein, M.D.
Redesigned for Maximum Ease of Use Platinum has been designed for the ultimate
Vbeam PLATINUM SPECIFICATIONS
ease of use. Each console is sleeker and smaller
Laser Type
Pulsed Dye
Wavelength
595 nm
Pulse
0.45-40 ms
Spot Sizes (diameter) with maximum energy
3 mm - 40 J/cm2 5 mm - 30 J/cm2 7 mm - 20 J/cm2 10 mm - 10 J/cm2 12 mm - 7 J/cm2 3x10 mm - 25 J/cm2
Beam Delivery
Lens-coupled 3 m optical fiber with handpiece
Pulse Control
Fingerswitch, Footswitch
Dimensions
43" H x 16" W x 30" D** (109 cm x 40 cm x 76 cm)
Weight
290 lbs (132 kg)
Electrical
230 V 50/60 Hz, single phase, 18A
than ever before for ease of maneuverability from treatment room to treatment room. Yet, it features a large 10” screen with touch-screen technology for a user-friendly interface. Onscreen graphics are easy to read and provide clear, simple-to-follow treatment guidelines.
39" (99 cm) D with dye cartridge
**
DYNAMIC COOLING DEVICE Integrated controls, cryogen container and handpiece with distance gauge
LASER LIGHT AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED LIGHT CLASS 4 LASER PRODUCT (Per EN60825-1: 2002-07) MAXIMUM PULSE ENERGY 8J PULSE WIDTH .45–40 ms WAVELENGTH 595 nm
Complies with FDA performance standards for laser products except for deviations pursuant to laser Notice No. 50 dated July 26, 2002
AIMING BEAM — CLASS 1 MAXIMUM POWER 5mW PULSE WIDTH CW WAVELENGTH 520–550 nm
0123
Specifications subject to change without notice. Vbeam is a registered trademark of Candela Corporation. Dynamic Cooling Device and DCD are trademarks. ©2005 Candela Corporation. All rights reserved. Printed in the USA. 11/05 0920-20-0054 Rev. 03
Cryogen
HFC 134a
DCD Spray Duration
User adjustable range: 20 - 100 ms
DCD Delay Duration
User adjustable range: 10 - 100 ms
Candela Corporation 530 Boston Post Road Wayland, MA 01778 USA Phone: (508) 358-7637 Fax: (508) 358-5569 Toll Free: (800) 821-2013 www.candelalaser.com
Redesigned for Maximum Ease of Use Perfecta has been designed for the ultimate
Vbeam PERFECTA SPECIFICATIONS
ease of use. Each console is sleeker and smaller
Laser Type
Pulsed Dye
Wavelength
595 nm
Pulse
0.45-40 ms
Spot Sizes (diameter) with maximum energy
3 mm - 40 J/cm2 5 mm - 30 J/cm2 7 mm - 20 J/cm2 10 mm - 10 J/cm2 12 mm - 7 J/cm2 3x10 mm - 25 J/cm2 7 mm PL - 15 J/cm2 10 mm PL - 10 J/cm2
Beam Delivery
Lens-coupled 3 m optical fiber with handpiece
Pulse Control
Fingerswitch, Footswitch
Dimensions
43" H x 16" W x 30" D** (109 cm x 40 cm x 76 cm)
Weight
290 lbs (132 kg)
Electrical
230 V 50/60 Hz, single phase, 18A
than ever before for ease of maneuverability from treatment room to treatment room. Yet, it features a large 10” screen with touch-screen technology for a user-friendly interface. Onscreen graphics are easy to read and provide clear, simple-to-follow treatment guidelines.
39" (99 cm) D with dye cartridge
**
DYNAMIC COOLING DEVICE Integrated controls, cryogen container and handpiece with distance gauge
LASER LIGHT AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED LIGHT CLASS 4 LASER PRODUCT (Per EN60825-1: 2002-07) MAXIMUM PULSE ENERGY 8J PULSE WIDTH .45–40 ms WAVELENGTH 595 nm
Complies with FDA performance standards for laser products except for deviations pursuant to laser Notice No. 50 dated July 26, 2002
AIMING BEAM — CLASS 1 MAXIMUM POWER 5mW PULSE WIDTH CW WAVELENGTH 520–550 nm
0123
Specifications subject to change without notice. Vbeam is a registered trademark of Candela Corporation. Dynamic Cooling Device and DCD are trademarks. ©2005 Candela Corporation. All rights reserved. Printed in the USA. 11/05 0920-20-0056 Rev. 03
Cryogen
HFC 134a
DCD Spray Duration
User adjustable range: 20 - 100 ms
DCD Delay Duration
User adjustable range: 10 - 100 ms
Candela Corporation 530 Boston Post Road Wayland, MA 01778 USA Phone: (508) 358-7637 Fax: (508) 358-5569 Toll Free: (800) 821-2013 www.candelalaser.com
PERFECT FOR EVERYTHING
PERFECTA Perfecta can do it all: from rejuvenation by correcting red and brown skin discoloration, like Aesthetica, to eliminating virtually all vascular and pigmented lesions, like the Platinum. The Perfecta features advanced micro-pulse technology, multiple handpieces for treating various spot sizes, and our patented Dynamic Cooling Device™ (DCD™) cooling system, which all but eliminates patient downtime by Perfecta is backed by Candela’s unmatched training, marketing and service—including a financing program that’s right for your practice. One laser for all these treatment conditions: •
Skin Rejuvenation
•
Acne
•
Angiomas
•
Venous Lakes
•
Diffuse Redness
•
Facial Veins
•
Hemangiomas
•
Psoriasis
•
Pigmentation
•
Leg Veins
•
Port Wine Stains
•
•
Freckles
•
Pigmented Lesions
•
•
Sun Spots
•
Wrinkles
Scars and Stretch Marks
Benign Gynecological Vascular Lesions
•
Other Benign Cutaneous Vascular Lesions
•
Rosacea
•
Poikiloderma of Civatte
•
Warts
PERFECT FOR EVERYTHING
preventing purpura, or bruising. And like all Candela products,
See for yourself Perfecta’s unmatched versatility. PRE AND POST-TREATMENT RESULTS
Brown Pigmentation
Courtesy of Taro Kono, M.D.
Periorbital Wrinkles
Courtesy of Stephen W. Eubanks, M.D.
Leg Veins
Hemangioma
Courtesy of David B. Vasily M.D.
Courtesy of Ross S. Kaplan, M.D.
Brown Pigmentation
Redness
Port Wine Stain
Nose Veins
Courtesy of Taro Kono, M.D.
Courtesy of David A. Laub, M.D.
Courtesy of Gerald N. Goldberg, M.D.
Courtesy of Pablo Bioxeda, M.D.
Poikiloderma of Civatte
Rosacea
Port Wine Stain
Scar
Courtesy of Stephen W. Eubanks, M.D.
Courtesy of J. Charlie Finn, M.D.
Courtesy of Fine Lines Cosmetic Center
Courtesy of Jeffrey S. Dover, M.D.
Acne Redness
Rosacea
Venous Lake
Warts
Courtesy of Wichai Hongcharu, M.D.
Courtesy of Ross S. Kaplan, M.D.
Courtesy of Fine Lines Cosmetic Center
Courtesy of Catherine Smadja, M.D.
THE TECHNOLOGY YOU WANT. THE FLEXIBILITY YOU NEED. The advanced technology of Vbeam is more accessible than ever thanks to Pathways—your path to unprecedented Choice, Flexibility and Value. The choice of a complete range of innovative technologies for optimal treatment. The flexibility to meet your specific needs today, then easily upgrade as you expand your practice. The value that comes from cost-effectively growing your business—step-by-step, with the leader in medical and aesthetic lasers.
To learn more about Pathways, visit Candela at www.candelalaser.com/pathways.cfm or call 1-800-821-2013.
LASER LIGHT AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED LIGHT CLASS 4 LASER PRODUCT (Per EN60825-1: 2002-07) MAXIMUM PULSE ENERGY 8J PULSE WIDTH .45–40 ms WAVELENGTH 595 nm
Complies with FDA performance standards for laser products except for deviations pursuant to laser Notice No. 50 dated July 26, 2002
AIMING BEAM — CLASS 1 MAXIMUM POWER 5mW PULSE WIDTH CW WAVELENGTH 520–550 nm
0123
**Patent pending. Specifications subject to change without notice. Vbeam is a registered trademark of Candela Corporation. Dynamic Cooling Device and DCD are trademarks. ©2005 Candela Corporation. All rights reserved. Printed in the USA. 11/05 0920-20-0053 Rev. 03
Candela Corporation 530 Boston Post Road Wayland, MA 01778 USA Phone: (508) 358-7637 Fax: (508) 358-5569 Toll Free: (800) 821-2013 www.candelalaser.com