The Integrated line of refrigeration is growing literally

Planning Information Model 736TC(I) Over-and-Under Refrigerator | Freezer Model 736TC Electronic digital control panel Seamless molding Adjustabl...
Author: Earl Jennings
45 downloads 2 Views 223KB Size
Planning Information

Model 736TC(I) Over-and-Under Refrigerator | Freezer

Model 736TC

Electronic digital control panel

Seamless molding

Adjustable spill-proof glass shelves

Adjustable dairy compartment

Egg container

Adjustable door shelves

Crisper

Location of serial number

Magnetic door / drawer gaskets

Automatic ice maker (Model 736TCI)

Upper freezer storage drawer

Front venting with removable kickplate

Lower freezer storage drawer

Model 736TCI with Ice Maker

With the installation of a harness kit, these appliances are Star-K compliant to meet strict religious regulations in conjunction with specific instructions found on star-k.org. You may purchase this harness kit through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.

The Sub-Zero Model 736TC and 736TCI integrated design accepts custom wood or stainless steel door and drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes—classic, platinum and carbon.

IMPORTANT NOTE: When planning for custom door panels for Model 736TC or 736TCI, refer to "Integrating Cabinetry" in the Integrated General Applications section of this Planning Guide. These pages explain in detail areas you need to plan for. Panel sizes for Model 736TC and 736TCI are exactly 9" (229) wider that those for other Integrated tall units.

Dimensions in parentheses are in millimeters unless otherwise specified. 10/05

The Integrated line of refrigeration is growing—literally and figuratively. We’ve introduced the Model 700BC that takes integrated refrigerator and freezer space to the base unit and now we have grown the same concept to 36" (914). Yes, that’s correct, the Integrated line is not only 27" (686) wide, you can order a tall combination unit that is 36" (914) wide. This unit will be perfect for those smaller kitchens that required more storage space than the Model 700TC could offer. All of the panel specifications are identical, except they have grown 9" (229) wider.

1

Planning Information

Model 736TC(I)

F E AT U R E S

Tall 36" (914) wide combination unit with upper cabinet refrigerator and freezer storage drawers Model 736TCI has automatic ice maker Integrated design for "point-of-use" refrigeration anywhere in the home Dual refrigeration system with two distinct temperature zones ensures the freshest food and energy efficiency Electronic digital controls are up front and easy to use Flat to the ceiling bright lighting in cabinet and drawers

Door alarm will let you know with an audible beeping if a door or drawer is left open Adjustable spill-proof glass shelves Refrigerator deli drawer for storage of smaller items The exclusive dual action hinge has a built-in 90˚ door stop Meets strict Department of Energy requirements UL approved for US and Canada Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com

OVERALL DIMENSIONS

36"

24"

(914) (UNIT DIMENSION)

(610) (UNIT DIMENSION)

TOP OF ROUGH OPENING

14"(356) 15/16" (33)

24" DOOR MOUNTING DETAIL

(610) DOOR / DRAWER CLOSED

DOOR / DRAWER CLOSED

80"* (2032)

90˚ 3/8"

7713/16"*

(10)

(1976)

191/2"* 341/2"* (495) (876)

105˚

347/8" (886)

131/4" 1/2" (337) (13)

DRAWER MOUNTING DETAIL

90˚ DOOR OPENING

341/2"* 101/4"

MAXIMUM DOOR OPENING

7"* (178)

TOP VIEW *DOOR / DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION

(876)

(260)

203/8"

93/4"

(518)

(248)

4"

FRONT VIEW

(102)

SIDE VIEW

*1/2" (13) +_ ADJUSTMENT IN LEVELING LEGS

Dimensions may vary by ± 1/8" (3).

Dimensions in parentheses are in millimeters unless otherwise specified.

2

Planning Information

Model 736TC(I)

S P E C I F I C AT I O N S

Model 736TC(I)

Over-and-Under Refrigerator /Freezer

Overall Width

36" (914)

Overall Height

80" (2032)

Overall Depth

24" (610)

MODEL OPTIONS

Refrigerator Capacity

Over-and-Under Refrigerator/Freezer Over-and-Under Refrigerator/Freezer with Automatic Ice Maker

736TC

13.5 cu ft (383 L)

Freezer Capacity

6.9 cu ft (195 L)

Minimum Height (levelers in) 736TCI

Door Clearance

34 1/2" (876)

Drawer Clearance

19 1/2" (495)

Electrical Requirements

PA N E L O P T I O N S

Plumbing Requirements

Integrated (custom panels) Classic Stainless Steel Finish

/S

Water Supply

Platinum Stainless Steel Finish

/P

Annual Energy Usage

Carbon Stainless Steel Finish

/B

Shipping Weight

Stainless steel door and drawer front panels are ordered and shipped as sales accessories and include tubular handles.

79 1/2" (2019)

Special Note

115 V AC, 60 Hz, 15 amp circuit 1/ 4"

copper line 20–100 psi

569 kWh / $ 48 480 lbs (218 kg)

Door and drawer panels and handles are available in three stainless steel finishes

Specifications are subject to change without notice.

ACCESSORIES

Tubular handles in classic, platinum and carbon stainless steel Shelf and deli drawer assembly Dozen egg container with lid Dual installation heater kit (TTDUAL or BBDUAL) Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.

Dimensions in parentheses are in millimeters unless otherwise specified.

3

Planning Information

Model 736TC(I)

I N S TA L L AT I O N S P E C I F I C AT I O N S TOP VIEW

11/2" (38)

25"

(635)

TOP VIEW

6"

ANTI-TIP BRACKET

(152)

18" (457) CL

20" (508)

27"

13 1/2"

ANTI-TIP BRACKET

18" (457)

(686)

27"

CL

(686)

WATER LINE SIDE ENTRY LOCATIONS

(343) WATER LINE BOTTOM ENTRY LOCATION

11/2"

11/2"

(38)

(38)

36"

25"

(914)

(635)

LOCATE ELECTRICAL WITHIN SHADED AREA – ORIENT GROUND PRONG TO RIGHT AS SHOWN LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA

ANTI-TIP BRACKET

80"

(2032)

4 1/2"

3"

(114)

(76)

1/4" (6)

17 1/2" (445)

13 1/2" (343)

2 1/2" (64)

3/4" (19)

20" (508)

NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD

ANTI-TIP BRACKET

FRONT VIEW

WATER LINE SIDE ENTRY LOCATION

SIDE VIEW

Dimensions may vary by ± 1/8" (3).

DIMENSIONS

Finished Rough Opening Width

36" (914)

Finished Rough Opening Height

80" (2032)

Finished Rough Opening Depth

25" (635)*

Location of Electrical

Within shaded area

Location of Plumbing (Model 736TCI only)

Within shaded area

* The depth of the Model 736TC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified.

4

Planning Information

Model 736TC(I)

I N S TA L L AT I O N N OT E S

Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. The depth of Model 736TC (I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration. The anti-tip bracket must be installed to prevent the unit from tipping forward. Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets. Refer to the full-scale illustrations at the end of this section for specifics on panels and door openings. Door panels can grow beyond the 80" (2032) height to accommodate any size of door as long as you stay below the recommended door panel weight limit of 53 lbs (24 kg). Door panels must be a minimum of 5/8" (16) thick. The weight of each drawer panel cannot exceed 16 lbs (7 kg). Drawer panels must be a minimum of 5/8" (16) thick. For the bottom drawer, the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser. We recommend using D-style handles, which should be located on the opposite side from the hinge, centered on the cabinet door and the top, center area of the drawer panel. Two Integrated units may be installed next to one another. Refer to page 11 for additional information. For Integrated models with an automatic ice maker, rough in the water supply line. Connect a 1/4" OD copper line to the house supply, being sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.

Dimensions in parentheses are in millimeters unless otherwise specified.

Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently. When routing the water through the side walls, you must place the water line within 1/2" (13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip bracket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration for placement of the water line. Do not route water supply line in front of the compressor tray. The tray must be slid forward for service. Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration. A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary. All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration. Do not use an extension cord or two prong adapter. Electrical ground is required. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The Integrated Installation Guide packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.

5

Planning Information

Model 736TC(I) I N T E G R AT I N G C A B I N E T RY C A B I N E T RY A P P L I C AT I O N S

Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the doors and/or drawers. As you look at styles of cabinets, keep some important facts in mind: Weight Limitations – The door panel cannot exceed 53 lbs (24 kg) and each drawer panel must not exceed 16 lbs (7 kg). Panel Thickness – Door and drawer panels must be a minimum of 5/8" (16) thick. The height of the door panel can grow beyond 45 3/8" (1153) and exceed the 80" (2032) overall height as long as you stay below the recommended door panel weight limit. The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. We recommend using D-style handles. For the cabinet door, handles must be located near the edge of the panel opposite the hinge, centered top to bottom. Locate handles in the top center area of the drawer panels. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit.

As the reveal between cabinets and the Integrated unit decreases, the potential exists for severe finger pinching or crushing if a hand or fingers are placed in the opening when the door is closing.

Dimensions in parentheses are in millimeters unless otherwise specified.

6

Planning Information

Model 736TC(I) I N T E G R AT I N G C A B I N E T RY F R A M E D C A B I N E T RY A P P L I C AT I O N S

Framed cabinetry applications present you with different questions to address. The illustrations on this page show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country. Also refer to the fullscale illustrations at the end of this section for specifics on door openings.

FRAMED CABINETRY

SUB-ZERO UNIT

CABINET FRAME

CABINET DOOR

24 (610)

TO WALL

PANEL

1/8" (3) REVEAL

IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Refer to the illustrations.

36 (914)

1

Traditional Frame – full overlay. 3

T SUB-ZERO UNIT

CABINET FRAME

24

Illustrations on the following pages give dimensions for an Integrated base or tall unit installed within a framed cabinetry beaded inset application. Review the illustrations, giving particular attention to the overall panel specifications. Also refer to the full-scale illustrations at the end of this section for specifics on door openings.

(610)

TO WALL

1

CABINET DOOR

PANEL

1/8" (3) REVEAL

3 36 (914)

Traditional Frame – standard overlay.

S T SUB-ZERO UNIT

24 (610)

TO WALL

CABINET FRAME

1

CABINET DOOR

1/8" (3) REVEAL

PANEL

3

36 (914)

Traditional Frame – 3/8" (10) offset.

Dimensions in parentheses are in millimeters unless otherwise specified.

7

Planning Information

Model 736TC(I)

F R A M E D C A B I N E T RY – B E A D E D I N S E T A P P L I C AT I O N

24"

The illustration shows a Model 736TC(I) installed within a framed cabinetry beaded inset application.

(610)

SUB-ZERO UNIT

CABINET DOOR

TO WALL

IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly.

DOOR PANEL

A

A

A) ALL REVEALS ARE 1/8" (3) B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS C) BOTTOM RAIL MUST BE REMOVABLE

36"

TOP VIEW

(914)

*DIMENSIONS MAY VARY

35 3/4" (908) PANEL WIDTH

11/2" (38)

47 7/8"

84"

(1216)

(2624)

SHADED AREA INDICATES STATIONARY STYLES AND RAILS

80"*

(2032)

A

B

13 9/16" (345)

A

B

341/2" (876)*

15 1/16" 11/2" (38)

(383)

A

C

4"*

36"

(914)

11/2" (38)

11/2" (38)

FRONT VIEW

(102)

4" (102) 24"

(610)

SIDE VIEW

Installation of a Model 736TC(I) within framed cabinetry. *Dimensions may vary. Dimensions in parentheses are in millimeters unless otherwise specified.

8

Planning Information

Model 736TC(I)

F R A M E L E S S C A B I N E T RY A P P L I C AT I O N S

The illustration below shows a hypothetical installation of a Model 736TC(I) within frameless cabinetry. Review the illustration, giving particular attention to the overall panel specifications. Also refer to the full-scale illustrations at the end of this section for specifics on door openings. IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly. FRAMELESS CABINETRY

35 3/4"* (908)

24"

PANEL WIDTH

(610)

A

45 3/8" (1153)

80"*

(2032)

79 7/8"* (2029)

A

13 9/16" (345)

A

341/2" (876)*

16 11/16"* (424)

4"* (102)

36"

(914)

TOE KICK

SIDE VIEW

FINISHED OPENING A) ALL REVEALS ARE 1/8" (3)

*DIMENSIONS MAY VARY

Installation of a Model 736TC(I) within frameless cabinetry. *Dimensions may vary. Dimensions in parentheses are in millimeters unless otherwise specified.

9

Planning Information

Model 736TC(I)

PA N E L C O N S I D E R AT I O N S

The illustrations below provide panel width dimensions for installation of a single Model 736TC(I) and for installing two Model 736TC(I) units side by side.

When 5/8" (16) or thicker panels are used and a reveal less than 1/4" (6) is maintained, the door panels may cause damage to the Sub-Zero unit when the door is open at the maximum 105˚ door stop. You should use the built-in 90˚ door stop to prevent damage.

IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly.

36 (914)

* 1 (3) min 8 REVEAL

* 1 (3) min 8 REVEAL

35 43 (908)

3 4 (19) PANEL

34 87 (886)

25 (635)

CABINETRY OR SIDE PANEL

24 (610)

25 (635)

APPLIANCE DOOR WIDTH

CABINETRY OR SIDE PANEL

TO BACK OF UNIT

SUB-ZERO UNIT

*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL *

72 (1829) * 1 (3) min 8 REVEAL

13 (910) 35 16

13 (910) 35 16

* 1 (3) min 8 REVEAL

* 1 (3) min 8 REVEAL 3 4 (19) PANEL

25

25 C (635) CABINETRY OR SIDE PANEL

24 (610)

Panel width dimensions for installation of two Model 736TC(I) units side by side.

3 4 (19) PANEL

(635)

CABINETRY OR SIDE PANEL

Panel width dimensions for installation of a single Model 736TC(I).

DOOR

DOOR

SUB-ZERO UNIT

SUB-ZERO UNIT

TO BACK OF UNIT

*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL

Dimensions in parentheses are in millimeters unless otherwise specified.

10

Planning Information

Model 736TC(I)

CABINETS

25 (635)

I N S TA L L AT I O N O P T I O N S

36 (914)

TOP VIEW

3 Installation without side panels.

C

The illustrations on this page show some typical installations and their dimension considerations. The depth dimension in the illustrations may vary depending on cabinet styles, treatment of countertops or other design options. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustrations.

CABINETS

25 (635)

3 36 (914)

MINIMUM 5/8" (16) SIDE PANELS

D UA L I N S TA L L AT I O N S

Installation with side panels.

CABINETS

25 (635)

T

If two or more Integrated models are installed side by side where there is 2" (51) or less of space between the units, a heater kit is recommended— TTDUAL for a Model 736TC(I) installed with another tall unit or two Model 736TC(I) units installed side by side and BBDUAL for a base unit and a Model 736TC(I) unit installed side by side. These optional components are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.

72 (1829)

TOP VIEW

Installation of two units side by side.

C CABINETS

25 (635)

3 M

36 (914)

MINIMUM

5/8"

(16) SIDE PANELS

Installation at end of run.

Dimensions in parentheses are in millimeters unless otherwise specified.

11

Planning Information

Model 736TC(I)

D O O R PA N E L H E I G H T

The height of the door panel can grow beyond 45 3/8" (1153) and exceed the 80" (2032) overall height, as long as you stay below the recommended door panel weight limit of 40 lbs (18 kg) for 27" (868) wide units and 53 lbs (24 kg) for the Model 736TC(I). The illustration below shows how the panel may grow and what you need to consider doing to finish the area in back of the door panel. IMPORTANT NOTE: The valance you use to finish the area behind the door panel must stay behind the front plane of the finished molding as shown in the illustration. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration.

U P P E R VA L E N C E D E TA I L

25 (635)

TO WALL

1 21 (38) DECORATIVE VALANCE CANNOT EXTEND BEYOND THE FRONT OF THIS PLANE

DECORATIVE VALANCE 1 4 (6)

REMOVABLE MOLDING BY SUB-ZERO

45 83 (1153)

TO BOTTOM OF DOOR PANEL

TOP HINGE

80* (2032)

TO FLOOR

*FINISHED HEIGHT OF 80" (2032) IS TO TOP OF SUB-ZERO MOLDING

Dimensions in parentheses are in millimeters unless otherwise specified.

12

Planning Information

Model 736TC(I)

TOE KICK CLEARANCE

The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). IMPORTANT NOTE: You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser. The illustration below shows the area below the lower drawer where the operating mechanical equipment of the Integrated unit is housed. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration.

TO E K I C K A R E A D E TA I L

9 1016 (268)

PANEL

1 2 (13) 11 1616 (424)

PANEL

11 9 16 (246)

10 (254)

OPTIONAL

BASE MOLDING MUST BE REMOVABLE

4 24

(102)

(610) TO WALL

2 85 TO 4 (67) (102)

Dimensions in parentheses are in millimeters unless otherwise specified.

FLOOR

13

Planning Information

Model 736TC(I) SUB-ZERO DOOR

F U L L - S C A L E T E M P L AT E

FRAMED CABINETRY

IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit.

24

T

(610)

TO BACK OF UNIT

LINE OF INTERFERENCE*

105˚ maximum door opening – 1/4 scale (top view)

LINE OF INTERFERENCE* AT MAXIMUM DOOR OPENING MOUNTING BRACKET SCREW

1 (3) MIN. 8

REVEAL

PANEL 3 4 (19)

34 87 (886)

APPLIANCE DOOR WIDTH

SUB-ZERO DOOR

24 (610)

TO BACK OF UNIT

LINE OF INTERFERENCE* SIDE MOLDING AND INSTALLATION HARDWARE PROVIDED BY SUB-ZERO

FLUSH FURNITURE FINISH

Door closed – full scale (top view)

Dimensions in parentheses are in millimeters unless otherwise specified.

*If the panel is thicker than 3/4" (19), it is recommended that you utilize the built-in 90˚ door stop to prevent damage to the panel and face frame. 14

Planning Information SUB-ZERO DOOR

Model 736TC(I)

3/4" (19) DOOR

F U L L - S C A L E T E M P L AT E

COUNTERTOP

PANEL SIDE PANEL

FRAMELESS CABINETRY

IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit.

24 (610)

TO WALL

LINE OF INTERFERENCE*

105˚ maximum door opening – 1/4 scale (top view) Adjacent side panel and countertop application

1 (3) MIN. 8

LINE OF INTERFERENCE* AT MAXIMUM DOOR OPENING

REVEAL MOUNTING BRACKET SCREW

3 4 (19)

PANEL

34 87 (886)

APPLIANCE DOOR WIDTH

SUB-ZERO DOOR

24 (610)

TO BACK OF UNIT

LINE OF INTERFERENCE* SIDE MOLDING AND INSTALLATION HARDWARE PROVIDED BY SUB-ZERO

Door closed – full scale (top view)

Dimensions in parentheses are in millimeters unless otherwise specified.

*If the panel is thicker than 3/4" (19), it is recommended that you utilize the built-in 90˚ door stop to prevent damage to the panel and face frame. 15