European HEATPUMP KEYMARK
Overview
www.heatpumpkeymark.eu 1
European HEATPUMP KEYMARK | Overview | 2015
The EHPA quality label in Europe An unpleasant future… - tomorrow 0
300 km
0
300 mi
P-Mark/ Nordic Swan
• Multiple schemes • Multiple FPC • No mutual acceptance • èMore work/time • èhigher cost Harp
MCS
DK-List Koermark DACH QUEST
• Better quality?
NF-PAC 2
European HEATPUMP KEYMARK | Overview | 2015
POL-Q CZ+
Idea of a single certificate was developed
from 2013 - 2015 • Requirements – – – – –
A single certificate Open to all interested parties Transparent and strong to create trust in the market place Mutually accepted no minimal requirements
Indirectly, due to Ecodesign, minimum requirements will apply (eta s, noise)
• Need to incorporate a transition period for the different existing schemes:
EHPA – quality label, MCS in UK, NF-Pac in France, heat pumps positive list in Denmark, Harp list in Ireland • Consideration of cooperation with existing schemes, development of EHPA certificate • Conclusion: development of CEN HP KEYMARK as a sufficient proof of heat pump quality in Europe 3
European HEATPUMP KEYMARK | Overview | 2015
European heat pump KEYMARK • ISO type 5 system according to ISO 17065 – – – –
One set of test requirements Application via empowered bodies Factory Production Control (FPC) A quality assurance system
• Open for all interested certification bodies • Mutually accepted in all EU Member States
4
European HEATPUMP KEYMARK | Overview | 2015
Pre-Scheme Development Group
•
Certification Bodies – DIN CERTCO – BRE – SP Cert
§ Associations – Ehpa (Secretariat) – Informative: national associations – Informative: EHI, BDH (supportive!)
§ Manufacturers
5
– Atlantic
– Nibe
– Daikin
– Stiebel Eltron
– Emerson
– Vaillant
– Dimplex
– Viessmann
European HEATPUMP KEYMARK | Overview | 2015
European heat pump KEYMARK Development •
25.6.2015:
•
31.8.2015
•
July to October 2015
5 pre-scheme development group meetings to accommodate comments
•
November
•
November
•
Ongoing
•
Ongoing become Nov./Dec 15 Q1/2016
• •
6
final draft of KEYMARK scheme documents
delivered to all interested parties Last date to collect comments (more than 700)
Sending of final version to CEN KEYMARK management (currently DIN CERTCO) Final approval of scheme documents by CEN KEYMARK management application procedure of certification bodies to become partners application procedure of test institutes to partners (via certification bodies ) introduction of HP KEYMARK in the market First meeting of the Scheme Group
European HEATPUMP KEYMARK | Overview | 2015
Current status of the scheme:
Final documents
7
• • • • • • • • • • •
HPK__Heatpump KEYMARK scheme rules HPK_Annex A_KEYMARK Requirements HPK_Annex B_FPC Requirements HPK_Annex C_FPC Report HPK_Annex D1_data sheet template HPK_Annex D2_certificate template HPK_Annex E_Test Points HPK_Annex F_Template for report of product modification HPK_Annex G_Rules for OBL and Brands HPK_Annex H_Testing lab requirement and recognition HPK_Annex I_KEYMARK transition rules
• •
HPK-01_SG-HP Internal rules HPK-02_scheme naming convention
•
Ovararching basis: CEN/CENELEC Internal regulations part 4 CERTIFICATION
European HEATPUMP KEYMARK | Overview | 2015
Scope Initial phase • Heat pumps covered by Lot 1 and Lot2 – heat pump space heaters providing heat to water-based central heating systems for space heating purposes. – heat pump combination heaters providing heat to waterbased central heating systems for space heating purposes and heat to deliver hot drinking and sanitary water. – Heat pump water heaters which are dedicated to providing hot drinking and sanitary water
•
Thermal capacity up to 400kW
Future – extension possible upon industry request
è complement self declaration as required by EU regulations 813/2013 and 814/2013
8
European HEATPUMP KEYMARK | Overview | 2015
CEN KEYMARK a true certificate
according to ISO 17065 •
• • •
9
The ERP performances to be certified on the basis of European standards : – For space heating heat pumps: Prated, ηS and sound in average climate – colder and warmer climate certification is optional – For combination heat pump : Prated, ηS , ηDHW and sound in average climate – colder and warmer climate certification is optional – For water heat pumps: ηDHW, V40 and , sound in average climat – colder and warmer climate certification is optional Testing according EN 14511- 4 Factory production control and Quality system Declared data of the manufacturer are reproducible and true – Model range approrach – Yearly surveillance (random choise by CB of unit and some testing points) – Re-rating procedure system (3 step approach)
European HEATPUMP KEYMARK | Overview | 2015
What is tested?
Definition of a type • Type: defined by the manufacturer
same heat source, heat sink and driving energy (gas, electricity etc.). • types covered by the KEYMARK Scheme – – – –
10
Air/water heat pumps Water/water (including brine/water) heat pumps Exhaust air/water heat pumps Direct expansion/water heat pumps
European HEATPUMP KEYMARK | Overview | 2015
What is tested?
Definition of a sub-type • Part of a type • identical refrigeration circuit design and – Identical compressor (same manufacturer and commercial reference) – Identical condenser and evaporator (same manufacturer and commercial reference) – Same defrost process (when relevant) – Expansion device: same technology
• For DHW heat pumps – Same tank volume – Same heat exchanger 11
European HEATPUMP KEYMARK | Overview | 2015
What is tested?
Definition of a model • „heat pumps using identical refrigeration circuits, but otherwise differ in design“ • As examples – – – –
With or with-out integrated circulator pump(s) With or with-out integrated storage tank With or without integrated back up heater Different sizes and corrosion protection of storage tank(s) – Different location and dimensions on pipe connections – Different brand names 12
European HEATPUMP KEYMARK | Overview | 2015
Admission test • Manufacturer declares data for all sub-types • Manufactures provides min. 3 units (traceable by serial number) to certification body (CB) • CB picks one of these and indicates testing conditions (climate/part load conditions) • Manufacturer orders the test with a recognized lab (Annex H) • Per 5 sub-types in a type, one sub-type is tested
13
European HEATPUMP KEYMARK | Overview | 2015
What will be tested?
Initial type test – heating HP Low temperature heat pump
Sound power level
1.
A7/W35 or B0/W35 or W10/W35 (EN 14511-2)
test according to EN 12102 for average climate at the
2.
Bivalent point (EN 14825), average climate
highest certified application temperature
3.
One other testing condition to be chosen by the
certification body (EN 14825, average climate)
Safety test (EN 14511-4) for all types
For any other climate, bivalent testing point
chapter 4.2.1 starting test according to table 1
shall be tested (EN 14825)
chapter 4.4 shutting off heat transfer medium flow chapter 4.5 complete power supply failure
4.
Medium temperature heat pump 1.
A7/W35/55 or B0/W35/55 or W10/W35/55 (EN 14511-2)
2.
Bivalent point (EN 14825, average climate)
3.
One other testing condition to be chosen by the
Additionally for air-water chapter 4.7 defrost test In case the heat pump can be used with brine or water, only one application (brine or water) shall be tested.
certification body (EN 14825, average climate) 4. 14
For any other climate, bivalent testing point shall be tested (EN 14825) European HEATPUMP KEYMARK | Overview | 2015
What will be tested?
Initial type test – Combi-HP Rating test combi heat pump
Sound power level
1.
A7/W55 or B0/W55 or W10/W55 (EN 14511-2)
test according to EN 12102 for average climate at 55°C
2.
Bivalent point (EN 14825, average climate)
3.
One other testing condition to be chosen by the
Safety test (EN 14511-4) for all types
certification body (EN 14825, average climate) 4.
For any other climate, bivalent testing point shall be tested (EN 14825)
Optional: test at 35°C
Domestic hot water test
chapter 4.2.1 starting test according to table 1 chapter 4.4 shutting off heat transfer medium flow chapter 4.5 complete power supply failure Additionally for air-water chapter 4.7 defrost test In case the heat pump can be used with brine or water, only one application (brine or water) shall be tested.
Tests according to EN 16147
15
European HEATPUMP KEYMARK | Overview | 2015
Surveillance test • One sub-type per type and manufacturing site • If type consist of heating and combi-heaters, at least one combination heater needs to be tested. • Unit to be chosen during factory inspection • Certification body determines testing conditions • To be tested – Heating mode: standard rating pint, bivalent point COP and P at one part load condition – Sound power level Devia&on from declared values triggers “penalty scheme”! – If applicable: COPDHW 16
European HEATPUMP KEYMARK | Overview | 2015
Tolerances • • • • •
17
Prated ηS , ηDHW V40 Schallleistungswert Sicherheitsprüfungen
8% 8% 3% 2dB(A) keine
European HEATPUMP KEYMARK | Overview | 2015
Performance test
admission test and annual control test Type: Air-water 6 subtypes 3k W
Manufacturer data
3k W
7k W
3rd party test
7k W
11 kW
Manufacturer data
11 kW
14 kW
Manufacturer data
14 kW
17 kW
3rd party test
17 kW
19 kW
Manufacturer data
19 kW
Year 1: admission test 18
One sub-type to be tested per type and manufacturing site
Year 2 and following: surveillance test
European HEATPUMP KEYMARK | Overview | 2015
1. year
CB choose randomly a unit of the production line or stock. This unit (A) is to be tested 3rd party (defined number of measuring points))
Pass: Next surveillance test aRer two years
Fail
Pass: Next surveillance test after one year
CB choose another specimen of the same sub-type to be tested unit (B). Manufacturer has the option to choose another recognised lab for this test Fail Full measurement of unit (B) and rerating of the sub-type according to results from second test
CB choose randomly a unit of the production line or stock. This unit (C) is to be tested 3rd party (defined number of measuring points))
2. year
Fail CB choose another specimen of the same sub-type to be tested unit (D). Manufacturer has the option to choose another recognised lab for this test Fail Full measurement of unit (D) and rerating of the type according to results from second test
CB choose randomly a unit of the production line or stock. This unit (E) is to be tested 3rd party (defined number of measuring points))
3. year
Fail
19
CB choose another specimen of the same sub-type to be tested unit (F). Manufacturer has the option to choose another recognised lab for this test Fail
Loss of KEYMARK for all sub-types in the failed type.
Factory inspection • Frequency: once per year and production site • Factory production control: Check of internal documents and site visit • Check of manufacturers Quality system in accordance to the elements of EN ISO 9001
20
European HEATPUMP KEYMARK | Overview | 2015
Transition rules Existing test reports resulting from EHPA-Q; MCS; NF-PAC will be accepted • Testreport based onEN 14511, EN 14825, EN 16147, EN 12102, EN 12309 • Testreport part of valid certificate / label by MSC, EHPA or NF-Pac • Testreport not older than 4 years • Testreport muss issued by a test lab participating in the KEYMARK scheme
• Valid FPC must be available • Transition rule valid for one year after introduction of HP KEYMARK
21
European HEATPUMP KEYMARK | Overview | 2015
Participants of the heat pump KEYMARK network CEN: Scheme owner Scheme development group: Highest decision making body
Interested parXes
Steering group
22
Operator: Technical and administraXve secretariat
Manufacturers CerXfcaXon bodies
CerXficaXon body WG
Inspectors
Inspector WG
Test labs
Test labs WG
HP associaXons European HEATPUMP KEYMARK | Overview | 2015
Complementary relation of heat pump KEYMARK
with other schemes MCS (equiv. for performanc
EU/NaXonal rules
EHPA quality label
RT 2012 etc.
equivalent
based on KEYMARK
EHPA heat pump KEYMARK: quality cerXficate
UK
VDE Cert DIN Certco
BRE BSRIA
TÜV VDE
23
BBA
ILK
CerXta Eurovent
Uni Stuagart
CETIAT CEIS
SP Cert (SE)
Quality Austria SP
European HEATPUMP KEYMARK | Overview | 2015
AIT
CEN rules Akkred. Switzerland WPZ
ISO 17065 ISO 17025
Cost of the scheme to the manufacturer • Cost per KEYMARK certificate | subject to application – testing – certification – surveillance • Cost for KEYMARK scheme management | per type / subtype – Licensing fee to CEN – Secretariat | HP KEYMARK scheme network • Cost per site | annual – Factory inspection
24
European HEATPUMP KEYMARK | Overview | 2015
What does that mean for the EHPA Quality label • Quality label will continue to receive support from EHPA – Maintenance and hosting of database and website – Organization of meetings
• Future to be re-assessed after 3 years • HP KEYMARK will be added as an alternative to test report in Quality label • On national level: KEYMARK shall be supported; National association shall not lobby for a connection of the Quality label to subsidies. QL strictly end consumer quality orientated. • QLC meetings continue, possibly less frequent, only members that use the QL • Technical group integrated in KEYMARK 3rd party test labs group, SG-HP 25
European HEATPUMP KEYMARK | Overview | 2015