Technical Specifications
Main Auditorium As of March 10th, 2015
Technical Coordinator: Phone number: Fax number: Email address:
Rowan Maclachlan (+61 7) (07) 54-757-770 (+61 7) (07) 54-757-766
[email protected]
Venue Coordinator: Phone number: Fax number:
Tim McGee (+61 7) (07) 54-757-775 (+61 7) (07) 54-757-766
Email Address
[email protected]
Website:
http://www.scvenuesandevents.com.au/
SHORTHAND PS = Prompt Side = Stage Left, OP = Opposite Prompt = Stage Right DS = Down Stage, towards the front of stage, US = Up Stage, towards the back of the stage CL = Centre Line, front centre to back centre of stage, SL = Setting Line, as at the front curtain Proscenium = Front wall of stage
STAGE Brief Stage Description:
Unraked stage with a proscenium arch and flying facilities. Hardwood floor covered with Masonite sheets. Screwing into the surface is permitted with approval of Technical Manager. Stage crossover is backstage corridor.
Stage distributed load limit Stage point load limit Stage rake
750kg/m2 (7.5Kpa) Unknown NO
Stage Dimensions: Proscenium Width Height
12000mm 5700mm
Setting Line Rear of proscenium (Allow 100mm for Front Curtain) Distance From (SL = Setting Line, CL = Centre Line) SL to DS edge of apron SL to first fly line SL to last upstage fly line SL to rear wall CL to OP wall (or obstruction) CL to PS wall (or obstruction) Stage to underside of grid
1400mm 0mm 8300mm 8500mm 8000mm 9000mm 12800mm
Overhead obstructions Catwalks either side of stage, 6000mm from ground, 7000mm from CL
Auditorium:
Flat polished wooden parquetry floor with retractable tiered seating unit at rear of venue. Seating capacity with additional Orchestra lift/pit seating installed Variable Seating capacity without Orchestra lift/pit seating installed 800 (Variable)
Orchestra Lift / Pit: Orchestra Pit
There is no dedicated orchestra pit. Flexible chair configuration means orchestra can reside on auditorium floor. Stage level at 980mm above auditorium. Orchestra pit level at 0mm below auditorium. Lift can be set at any height N/A SWL of orchestra lift N/A Dimensions of the orchestra pit Variable Orchestra pit maximum capacity Variable
Flying Facilities: Fly System Single purchase counterweight handline fly system. Fly System Details Operating Position Total number of Lines Panorama Lines Batten Drift Batten Type Batten Length Batten Extensions Batten Pick-ups Batten Point Load Batten W.L.L. Cradle Capacity LX bars can be swung Fly bars can be swung
Prompt Side Stage Level 28 installed N/A 11000mm 50mm O/D Lighting Pipe 14000mm N/A 5 300kg 250kg NO YES
SEE HANGING PLOT FOR LINE ALLOCATIONS AND FURTHER INFO
Hanging Plot: Line Type: SP = Single purchase, DP = Double purchase, MW = Motor Winch, HW = Hand Winch, HL = Handline W.L.L.: Maximum distributed load including bar weight
Line #
Distance from SL
Line Type
W.L.L
Venue Allocation
(hiring company use)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
200mm 400mm Not Installed 800mm 1000mm 1200mm 1400mm 1600mm 1800mm 2000mm 2200mm Not Installed 2600mm Not Installed 3000mm 3200mm Not Installed 3600mm 3800mm Not Installed 4200mm 4400mm Not Installed 4800mm Not Installed 5200mm 5400mm Not Installed 5800mm 6000mm Not Installed 6400mm Not Installed 6800mm Not Installed 7200mm 5800mm 7600mm 7800mm
SP SP
300kg 300kg
House Curtain Legs
Not available for use
SP SP SP SP SP SP SP SP
300kg 300kg 300kg 300kg 300kg 300kg 300kg 300kg
LX 1
Lighting Only Very close to LX1
SP
300kg
LX 2
SP SP
300kg 300kg
Legs Mid-stage Rust Curtain
SP SP
300kg 300kg
Black Boarder Black Scrim
SP SP
300kg 300kg
Legs
SP
300kg
LX 3
SP SP
300kg 300kg
Legs
SP SP
300kg
Black Boarder
SP
300kg
LX 4
SP
300kg
Legs
SP SP SP
300kg 300kg 300kg
Intended Use
Spare Cinema Screen Legs
Permanently Flown
Black Border
Black Boarder Black Smother Cyclorama
Lighting Only
Lighting Only
Drapery: *Type
Material
Colour
House Curtain Borders Legs Smother Cyclorama Scrim Scrim
Wool Fire Protected Wool Fire Protected Wool Fire Protected Wool Fire Protected
Dark Blue Black Black Black White Black White
Width
Height
Quantity
7900mm 15000mm 3000mm 7900mm 15000mm 15000mm 15000mm
6500mm 2500mm 6000mm 6500mm 6500mm 6500mm 6500mm
2 4 12 2 1 1 1
Access Equipment: Elevated Work Platform SNORKEL – UL25 Push around Vertical lift, one person only Maximum reach is 7.5m S.W.L - 150kg EWP Restrictions Outriggers must be used at all times, One staff member to be located on ground to assist whilst in use. Ladders 2 m Fibreglass 3.5m A-frame extension
Staging Units:
15 timber rostra, black, 1m x 2m @ 2/3/4/6/800mm heights
Stage Covers:
Style Dimensions Colour
Stage Traps:
NA NA NA
One small audio+power trap front centre stage
Safety Curtain: Safety Curtain installed .
NO
Loading Dock: Access
Truck access is via MILL STREET. Truck able to reverse up to loading dock via a shared lane way. Stage access is via goods lift. Trucks cannot remain parked in shared lane way before / after bumping. Goods lift load limit is 1700kg. Goods Lift dimensions: - H 2800mm x D 1900mm x W 1900mm Door: - H 2200mm x W 1200mm
Restrictions / Obstructions Loading Hatch is NOT at Stage Level
Access is via a goods lift directly to stage, most items will fit (like a 3m Tri-Truss piece on an angle for example), though larger items will need to either passed up to a loading hatch (3m above ground level) or walked up via carpark (about an 80m trip each way).
Rigging Notes
See roof plan on the next page.
Note: Front of stage refers to inside edge of proscenium. Total Distributed Loading of Fly Bars must be considered.
Staging Notes:
6 Rigging points from grid, load limits vary depending on fly system loads and must be discussed with the technical manager prior to bump-in.
All flown items must be rigged with rated equipment and is subject to approval by a venue technical representative.
Access to the side catwalks and FOH Bridge is from Level 2 backstage via permanent ladders.
Limited rigging gear available in house. Including lifting slings, some steel wire and various shackles/clamps etc.
LIGHTING Positions: Stage LX Bars
4 x Flown LX Bars over stage See hanging plot for standard LX bar locations
Orchestra Bar Setting Line to lighting bar
NA
Usable bar width
NA
Notes
NA
FOH Bridge #1 Setting Line to lighting bar
7500mm
Usable bar width
14000mm
FOH Bridge #2 Setting Line to lighting bar
NA
Usable bar width
NA
Balcony Bar Setting Line to lighting bar
Usable bar width
Notes:
17200mm 2 x 6500mm
Bars run OP and PS 3600mm void at centre 6 x Patched circuits FOH Perches (PS & OP) Centre Line to FOH Perch .
7900mm Distances are from the CENTRE LINE to PERCH BAR
Notes: Perch position is section of catwalk between pro arch and FOH bridge
FOH Booms (PS & OP) Setting Line to FOH Boom
NA
Control:
Lighting desk
GrandMA2 Light
Control Channels
2048
Signal output
DMX
Signal distribution
Two streams of DMX to dimmer rooms. Splits to LX1, 2 and 3, FOH and OP stage
Remote riggers available onstage
iPad
Dimmer Racks:
Outlets on LX1, 2 & 3 are hardwired to fully soft-patchable dimmer channels, individually addressable at the dimmer. (Every third outlet on LX 1 & 2, LX3 outlets 3-28 are able to be switched into a DMX controllable relay bypass (aka True Power) integrated into the LSC Teko dimmers, allowing for Moving Lights & Projectors etc. to be “hot powered”.
Racks 1 – 3 and 12 - 14 are hard-patchable Australian Standard 3-Pin, and allow addressing in banks of 12, ie. 1, 13, 25 etc.
Total Dimmers
Dimmer Locations
(168)
Rack 1 on FOH bridge centre (T1) Racks 2 - 3 in “Dimmer room” (T2) Racks 4 - 11 in “Dimmer room” (T3) Racks 12 and 13 on catwalk OP side of stage (T4) Rack 14 inside O.P. Proscenium (T1)
2.4Kw Dimmer Racks 2 x (T1) JANDS WMX digital (12 x Outlet, 10A CB) 2 x (T2) JANDS FPX digital (12 x Outlet, 10A CB) 4 x (T3) LSC Teko (12 x Hardwire 13A, Softpatchable) 4 x (T3) LSC Teko (As above w/ relay power bypass) 2 x (T4) LSC WALLPAK (12 x Outlet, 10A fuse)
Total dimmers @ 2.4kw per dimmer
(168)
5Kw Dimmer Racks
0
Total dimmers @ 5kw per dimmer
0
House Lights:
Independent control
House + Aisle Lighs
Control position
PS Stage Managers Desk and Control room
Fade time adjustable
NO (7 seconds from 100% to 0%)
Stage Luminare: Profiles Make
Model
ETC ETC Yin-Wei Yin-Wei
Source 4 Source 4 Source 4 copy Source 4 copy
Angle
18 / 32 25 / 50 18 / 32 25 / 50
Detail / Accessories
Watt
Total
750w 750w 750w 750w
21 12 12 10
Fresnel’s Make
Model
Detail / Accessories
Strand
8 inch
( 40 ) Barndoors
Watt
Total
1.2kW
40
Par Cans Make
Model
Angle
KUPO
PAR 64 240Vt
MFL
PAR 64 110Vt
MFL
Detail / Accessories
Single hook clamp, (4) floor stands 4 par bars, 4 single
Watt
Total
1000W
24
1000W
20
Wash Make
Model
Detail / Accessories
Watt
Total
STRAND
CODA 3
(3) cells per unit
500W
8
Detail / Accessories
Watt
Total
hanging brackets hanging brackets hanging brackets
930w 250W 100w
8 6 8
Watt
Total
1200W
2
Watt
Total
3000W
1 1
Movers Make
Model
Yin-Wei Martin Chauvet
ColorSpot700AT MAC 250+ ColourPix-M
Standard Mode Extended Extended Extended
Followspots Make
Model
Angle
Detail / Accessories
Selecon
Performer
5 – 20
6 colour magazine
Additional Lighting Item
Make
Model
Detail / Accessories
Mirror Ball Strobe
Generic Martin Atomic
24inch 3000
24in diameter ball with motor
Patching: Please request the latest dimmer patch from the Technical Coordinator Location
Quantity
Numbering
Detail / Accessories
(PS to OP)
FOH Bridge
20
Balcony Bar
6
LX BAR 1 LX BAR 2 LX BAR 3 LX BAR 4
30 30 24 24
1 – 20 Balcony loom 1-6 1 - 30 1 - 30 1 - 24 1 - 24
1 x 10amp GPO available on Bridge 14m from stage apron LX 1,2,3 are soft-patchable
Power: 3 Phase Outlets (3) Stage level (OP) (2) Dimmer Room (OP) (2) FOH Bridge (C) (1) Backstage (OP)
Cabling: 240v Extension Cable Various 1m, 5m, 10m, 20m leads (let your requirements be known in advance) Looms and Multicores (2) 20m 4-way Weiland (2) 20m 6-way Weiland 20m 6-way loom 3 phase Extensions
NONE
AUDIO Control Positions: As the venue seating is variable, actual operating position can vary. Control Room Main Bio Box 25m from stage, 4m high Auditorium By request, located centre of rear rows of stalls. 15m from stage Total seat allocation (12) Chairs Top of seating bank, often used in seated configurations as view from Control Room can be obscured.
Control & Amplification: Primary Mixer Allen & Heath iLive (iDR - 64 in / 32 out) Secondary Mixer Yamaha GA32 Amplifiers (2) AM 30002 1500W @ 4 ohms (foldback) (2) QSC PLX 1104 500W @ 4 ohms (foldback) (2) Quest QA 4004 1800W @ 4 ohms (in fill) EQ
Integrated
Integrated
FX Compression / Limiter / Gates Integrated Acoustic Technologies system processor
Speakers: FOH Speakers (12) Acoustic Technologies TLA-308 Line Array (6 per side, flown) (2) Acoustic Technologies BB07 2 x 18” Subs (2 per side, under stage) (2) AT FR07 Double 15” + Horn (optional in/side fill) (2) AT BB03 Double 18” Subs
Foldback (6) TASSO PS15 Passive Monitors 350W RMS
Playback Item
Make
Model
Detail
Total
CD Player
DENON
T650
Single CD + TAPE
2
PC
Generic
Tascam Interface
Stereo In/Out 24-bit 96KHz
1
Microphones Make Wired Shure Shure Shure Shure Beyer AKG EV Sennheiser Rode Sennheiser Crown Wireless Shure UR4D Shure UR4D Shure UR4D
Model
Detail/ Accessories
SM58 SM57 Beta 87 Beta 52 M88 451 RE90H K6 NTG-1 421
Use Vocal Instrument Kick Kick Instrument Hanging mics Shotguns Shotguns instrument Boundry
Beta 87 Belt pack Receiver
Total 12 16 2 1 1 1 5 5 4 3 3
6 8 10ch
Accessories Item D.I. Boxes
Model
Detail / Accessories
Total 10
Line Patching Location Audio Rack, O.P.
Quantity 64 / 32
Numbering 1 - 64
PS
32
1 – 32
DS Centre Trap
10
1 - 10
Detail iDR64 Analog core with split to Control Room, not used as standard Patchable at Audio Rack
Speaker Patching Location
Quantity
PS, Centre Trap OP, Centre Trap Centre Trap Back wall OP
1 1 2 4
Numbering
1 2 2+4 5-8
Detail
Monitor 1 Monitor 2 Monitor 4-8
Cabling: Audio Cable The theatre has a good stock of cable to accommodate the venue’s equipment. Multicores 30m 16 Channel (XLR), 4 return (TRS Jack) 15M 8 Channel (XLR) Dropbox 10m 8 Channel (XLR) Dropbox
AUDIO VISUAL Projectors Type Panasonic data projector
Model PT-DW6500
Detail / Accessories 6000 ANSI Lumens 16:9
Sanyo Data Projector
PLC-XU105
4:3
Total 2 1
Screens: Projection Screen
Front projection cinema screen 10m wide with additional masking, permanently rigged from fly line 7.
AV Playback Equipment: Item
Model
Pioneer Samsung BluRay Vision Mixer PC/Laptop
Edirol VX4 Generic
Detail / Accessories Single DVD Player Consumer Unit 4ch, 1xVGA, 3xHDMI, Composite, T-Bar and FX For multimedia presentations
Projector Rigging Points:
Mounting is available from FOH Lighting Bridge #1
Cabling:
(2) VGA-Cat 5 units HDMI-Cat6 unit (fixed install) 50m VGA 10m VGA 1 - 3m VGA 30m BNC composite 40m RGBHV (BNC)
Audio Visual Notes:
Lack of depth on the stage area restricts possibilities for rear projection.
Total 1 1 1 1
BACKSTAGE Communications: Stage Managers Desk Stage Managers desk is located in prompt corner. The desk is fitted with a light, clock, and phone, house/work light control, backstage paging microphone and a talkback master station with headset. Talkback Master Unit Distributed channels Total sub stations Total headsets Radio Units In-house Talkback patching located at:
JANDS SYSTEM, Located at SM Desk. (1) (8) (8) NA Control room PS, SM Desk OP Stage PS US Flyman Dimmer Room OP Gallery Grid above Stage
Paging / Show relay Paging to the dressing rooms is available from the stage managers desk. Show relay is distributed to all dressing rooms and green room. A T.V. monitor is provided in the green room and the prompt desk for a view of the stage from a camera located on the Lighting Bridge #1. Stage Monitor SM Position and Green Room Q Light System In house Q light system available Number of units
NO NA
Dressing Rooms Dressing Room
Capacity
Dressing Room 1 Dressing Room 2 Dressing Room 3 Dressing Room 4 Toilets
8 7 7 6
Toilets
Shower
2M 2F
NO NO NO NO YES YES
Details
Be conservative with hot-water.
Laundry / Wardrobe:
Washing Machines Dryers Drying rooms Iron / ironing board Clothes racks
(1) (1) NA (2) (4) in Dressing Rooms, (2) portable units
Production Facilities: Production Office Not available, often 4th dressing room is utilized. Phone
Yes, via Box Office.
Fax
Yes, via Box Office.
Internet access WIFI available on request, charged per day.
Greenroom:
Tea / Coffee facilities Fridge / freezer Microwave Running water
YES YES NO YES
Stage Door: Access
Stage door is located level one of Carpark, it is a fire exit and must not be obstructed. Whilst unlocked, stage door must be attended at all times.
ADDITIONAL FACILITIES & INFORMATION Orchestral:
Baby Grand Piano, brown Upright Piano, brown (25) Music Stands with sconces, black
Rehearsal Space:
NO
VENUE: Nambour Civic Centre shares the loading dock access driveway with other business, which prohibits standing of trucks in the laneway to load/unload unless prior arrangements with the Technical Coordinator have been made at least one week in advance. Parking of trucks in the dock is not possible, with the exception of some short pan (ie. 4t Budget Pantech) trucks.
Map showing Nambour Civic Centre and Loading Dock https://maps.google.com/maps?q=Nambour+Civic+Centre
Access is via a goods lift directly to stage, most items will fit (like a 3m Tri-Truss piece on an angle for example), though larger items will need to either passed up to a loading hatch (3m above ground level) or walked up via carpark (about an 80m trip each way).
Venue Contacts: Venue Address
52 - 64 Currie street, Nambour. Top level Centenary Square
Venue Postal Address
PO Box 590 Nambour Q 4560
Staff Contacts: Venue Coordinator
Tim McGee
Email Address
[email protected]
Phone Number
(+61 7) 07 54 75 7755
Administration Phone Number Email Address Fax Number Box Office Phone Number Email Address Fax Number
Lynne Carruthers (+61 7) 07 54 75 7755
[email protected] (+61 7) 07 54 75 7766 Linda Burns (+61 7) 07 54 75 7772
[email protected] (+61 7) 07 54 75 7766
Stage Phone Number
(+61 7) 07 54 75 7750
Venue Plans: Venue Plan Available Contact the Technical Coordinator. .