Table of Contents T12 Electronic and High Output Ballasts

Table of Contents T12 Electronic and High Output Ballasts Ballasts gelighting.com T8 Instant Start Understanding T12 Electronic Ballasts.............
2 downloads 0 Views 736KB Size
Table of Contents T12 Electronic and High Output Ballasts

Ballasts

gelighting.com

T8 Instant Start

Understanding T12 Electronic Ballasts........................14-2

T8 Programmed Start

ProLine® T12 For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps........................................................ 14-3 For T12 4 ft – 8 ft Slimline Lamps............................................................................ 14-6 T12 High Output................................................................14-7 Wiring Diagrams...............................................................14-8 Case Dimensions..............................................................14-9

Programmed Start Dimming T5 Electronic Programmed Start T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 14-1

HID Electronic & Electromagnetic

See page E-1 for warranty information.

Understanding T12 Electronic Ballasts Electronic T12 GE multivolt and dedicated voltage ProLine® T12 high-performance ballasts are designed for replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt ProLine® T12 ballasts have the same wiring and mounting requirements as standard magnetic ballasts and provide up to 20% energy savings by simply replacing the ballast. The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp ­electro­magnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency requirements. GE ProLine® T12 electronic ballasts meet the DOE minimum ballast efficiency requirements and also allow facility managers to reduce ballast maintenance inventories by consolidating the number of ballasts needed. GE ProLine® T12 ballasts operate both energysaving and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the multi-voltage ProLine® T12 can consolidate over 40 different magnetic ballasts. Performance Features • GE240RSMVN and GE240RS120 comply with FCC for residential use • Low-profile and lightweight housing ­simplifies installation and reduces ­transportation costs (GE240 = 1.3 lbs. lighter than magnetic; GE260 = 5.3 lbs. lighter than magnetic)

•P  arallel operation — if one lamp fails, others remain lit • Significantly quieter than magnetic • High-frequency operation virtually ­eliminates lamp flickering typical in T12 electromagnetic systems • Five-year limited ballast warranty

Electromagnetic T12 • Complete line of ballasts for 2-to-8 foot lamps, circleline and high-output lamps • 100% thermally protected • High-grade lamination steel assures lowest wattage loss • UL, CSA and/or cUL approved • 888-GEBALLAST on every ballast • Two-year limited ballast warranty

Color-Coded Ballast and Outer Box Labels 120V – Yellow 277V – Red Packaging • Standard 10 packs • IP Packs – individually packed with ­instructions • DIY – shrink-wrapped and tray-packed with instructions

GE Ballast LFL magnetic nomenclature

G E M - 2 GE Ballast M = Electromagnetic Ballast GEH = HID Maximum ­number of lamps supported by this ballast: 1, 2, 3, 4

14-2

3 2 - H O - R S - 1 2 0 - D I Y Lamp Watts (Primary Lamp) T8 = 32 – 4 foot, 59 – 8 foot T12 = 40 – 4 foot, 60 – 8 foot T12 Electronic = 40 – 2-4 foot, 2 pin 60 – 4-8 foot, 1 pin 96 – 4-8 foot HO, 2 pin T12 Magnetic = 40 – 2-4 foot, 2 pin 96 – 4-8 foot, 2 pin

IS = Instant Start, default if not shown RS = Rapid Start PH = Preheat PT= Preheat/Trigger H = Hybrid D50 = Dimming (min level)  = High Output HO VHO = Very High Output

120V – Yellow 277V – Red 220V – Green 240V – Orange 347 – Gray

Pack Type IP = Individual corrugated box per ballast 84T = Pallet bulk pack (84=840, 42=420 ballasts) DIY = Shrinkwrap ballast in tray pack DIY72 = Shrinkwrap ballast in pallet pack (Qty) No extension = 10 pack

See page E-1 for warranty information.

ProLine T12 T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps 74472 – GE240RS-MV-N (replaces 24107) ProLine® T12 Multivolt 120V – 277V 2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12

Dimensions

General characteristics

70°C (158°F) Normal Active A (20-24 decibels) Metal Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Order information Std. pack 74472

Pallet Pack

DIY Pack 74473 (replaces 24773)

IP Pack

9.5 in (241 mm) 1.3 in (33 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in.) 48.0 in (1219 mm) 33.0 in (838 mm) 33.0 in (838 mm) 25.0 in (635 mm) 25.0 in (635 mm)

Specifications by lamp and wattage Lamp

F40T10

F34T12

F30T12/WM

F20T12

Safety and performance

System Watts 74 73 48 48 75 72 42 42 63 62 41 41 50 50 30 30 60 58 37 37 46 45 28 29

Nom. Line Current 0.67 A 0.30 A 0.41 A 0.19 A 0.63 A 0.27 A 0.35 A 0.17 A 0.56 A 0.26 A 0.35 A 0.17 A 0.42 A 0.20 A 0.26 A 0.13 A 0.31 A 0.22 A 0.31 A 0.16 A 0.39 A 0.18 A 0.24 A 0.13 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 0.89 0.89

Ballast Efficacy Factor 1.20 1.22

0.88 0.88

1.17 1.22

0.87 0.87

1.38 1.40

0.95 0.95

1.90 1.90

0.95 0.95

1.58 1.64

1.00 1.00

2.17 2.22

UL Class P

NRCan

Power Factor% (>=) 99 97 99 95 99 94 99 88 99 96 99 94 99 91 99 82 99 96 99 94 99 94 99 92

FCC Part 18 Class B at 120 volts

cUL Listed

Crest Factor (