Contents 1 Introduction............................................................................................................. 1 1.1 Abbreviations ..................................................................................................... 1 1.2 Glossary ............................................................................................................. 2 2 Ascom IP-DECT System Overview .......................................................................... 3 2.1 System Size ........................................................................................................ 3 2.2 System Components .......................................................................................... 3 2.3 System Functions ............................................................................................... 5 2.4 LAN/WAN .......................................................................................................... 5 2.5 Supported third-party functions ......................................................................... 5 3 Ascom IP-DECT System ........................................................................................... 6 3.1 Software Components ....................................................................................... 6 3.2 System Layout .................................................................................................... 7 3.3 Standby System ............................................................................................... 17 3.4 Messaging in Multiple Master Systems ............................................................. 18 3.5 Broadcast Messaging in Multiple Master Systems ............................................. 18 3.6 Device Management ........................................................................................ 19 3.7 Fault Reporting ................................................................................................ 19 3.8 Load Balancing ................................................................................................ 19 3.9 Synchronization ............................................................................................... 20 3.10 Channel Distribution ...................................................................................... 21 3.11 Ascom IP-DECT System Management ............................................................. 22 4 VoIP Signalling Protocols ...................................................................................... 23 4.1 H.323 .............................................................................................................. 23 4.2 Session Initiation Protocol (SIP) ......................................................................... 23 5 Related Documents ............................................................................................... 24 Appendix A: Messaging Capacity ........................................................................... 26 Appendix B: Ascom Technical Documentation....................................................... 28

5 Mars 2010 / Ver. H

System Description Ascom IP-DECT System

1

TD 92375GB

Introduction This document gives a general description of the Ascom IP-DECT system, an IP based cordless telephony and messaging system for connection to private telephone exchanges. The Ascom IP-DECT system supports the DECT standard which gives a full integration of messaging and voice functions. The Ascom IP-DECT system can be integrated with external applications such as different alarm systems, networks and e-mail. This gives features such as; messages to Portable Device, alarm from Portable Device, message acknowledgement, and absent handling.

1.1

Abbreviations DECT

Digital Enhanced Cordless Telecommunications: global standard for cordless telecommunication.

HDB

Home location DataBase

ESS

Enhanced System Services: Unite module that supports advanced message routing and centralised fault handling and logging.

IMS2 and UPAC

Integrated Message Server: Unite module that enables messaging to and from the connected cordless telephone system.

IP

Internet Protocol: global standard that defines how to send data from one computer to another through the Internet

IPBS

IP-DECT Base Station

IPBL

IP-DECT Gateway

ISDN

Integrated Services Digital Network

LAN

Local Area Network: a group of computers and associated devices that share a common communication line.

LDAP

Lightweight Directory Access Protocol

PBX

Private Branch Exchange: telephone system within an enterprise that switches calls between local lines and allows all users to share a certain number of external lines.

PSTN

Public Switched Telephone Network

QoS

Quality of Service

RAS

Registration, Admission, Status (H.323)

RFP

Radio Fixed Part. DECT base station part of the DECT Infrastructure. Legacy DECT base station connected to an IPBL or the local RFP part in an IPBS.

SIP

Session Initiation Protocol

Unite

Generic term for messaging system that unites different systems, for example System 900, System 9d, and teleCARE M.

VoIP

Voice over Internet Protocol

5 Mars 2010 / Ver. H

1

System Description Ascom IP-DECT System

1.2

TD 92375GB

Glossary Roaming

The procedure of moving the Portable Device from one IPBS/IPBL to another and still be able to place outgoing and receive incoming calls.

External Handover

The procedure of moving an active call from one IPBS/IPBL to another.

System ID

System ID in the Pari Master defines the sync domain and handover domain. Within the coverage area, the System ID must be unique from other Ascom IP-DECT systems.

Master ID

Master ID must be unique for each Master in a system. The Standby Master must have the same id as the Master.

RFPI

The RFPI, Radio Fixed Part Identity, is the broadcast identity which uniquely identifies a RFP geographically.

Cover Radius

The radius of the circle (circular radiation patterns of the base station antennas are assumed), around a particular base station, in which portable parts can communicate with that base station.

Sync Radius The radius of the circle, around a particular base station, in which other Base Stations may synchronize with that Base Station. Sync Coverage

A sync coverage is the air sync coverage areas for all base stations connected to the same sync Master.

Sync Domain

Sync domain defines the Radios to which automatic synchronization is allowed. Sync domain is defined by the System ID.

Handover Domain

Handover domain defines the Radios to which external handover is allowed. Handover domain is defined by the System ID.

5 Mars 2010 / Ver. H

2

System Description Ascom IP-DECT System

2

TD 92375GB

Ascom IP-DECT System Overview The Ascom IP-DECT system is modular. It is designed for small installations as well as large multi-site installations with remote offices. The Ascom IP-DECT system is built up by the following components: • • • • • • •

Portable Devices IP-DECT Base Station (IPBS) IP-DECT Gateway (IPBL) Radio Fixed Part (RFP) IP-PBX Integrated Message Server (IMS2/UPAC) Unite System

PSTN (Public Switched Telephone Network)

IP-PBX RFP

RFP

RFP

IPBL LAN

IMS2 / UPAC

Unite Suite

IPBL RFP

RFP

Unite platform IPBS

001

IPBS

Figure 1. Ascom IP-DECT System Overview

2.1

System Size The Ascom IP-DECT system is very modular and scalable. Systems for more than 100 000 users can be built.

2.2

System Components

2.2.1

Portable Devices

The Ascom IP-DECT system has support for all Ascom DECT Portable Devices. No changes of the Portable Device is needed.

5 Mars 2010 / Ver. H

3

System Description Ascom IP-DECT System

2.2.2

TD 92375GB

IPBS

The IPBS has eight channels used for speech, message and alarm. The IPBS also has one channel which is reserved for messaging and alarm. 2.2.3

IPBL

Up to 16 RFPs can be conncted to the IPBL. The IPBL has eight channels for each RFP used for speech, message and alarm. The IPBL also has two channels which are reserved for messaging and alarm. Totally the IPBL has 40 speech channels. 2.2.4

RFP

All Ascom legacy DECT base stations can be connected to the IPBL. 2.2.5

IP-PBX

The Ascom IP-DECT system is connected to the IP-PBX with standardized H.323 or SIP protocol. 2.2.6

Integrated Message Server (IMS2/UPAC)

The IMS2 and UPAC contain support for messaging and alarm and connects the Ascom IP-DECT system to the Unite platform. The IMS2 and UPAC contain also a Device Manager which supports parameter and software download to portable devices. For more information, see the Unite documentation. All features are license dependent. 2.2.7

FXO

The FXO is a device that is used as an interface between the Ascom IP-DECT system an analogue PBX. For more information about FXO, see Configuration Notes for FXO in Ascom IP-DECT System, TD 92529GB.

5 Mars 2010 / Ver. H

4

System Description Ascom IP-DECT System

TD 92375GB

PBX

PSTN (Public Switched Telephone Network) analogue lines

FXO

LAN

4101

4103

021

IPBS

4102

Figure 2. Ascom IP-DECT system connected to a analogue PBX via FXO.

2.3

System Functions The Ascom IP-DECT system is designed to enable voice traffic, messaging and alarm handling between Portable Devices within an enterprise LAN. The Ascom IP-DECT system supports roaming and handover between all IPBSs and IPBLs in the system.

2.4

LAN/WAN There are several vendors providing components needed to deploy a LAN/WAN. In order to achieve optimal performance for IP-DECT the following is recommended: • Quality of Service (QoS) • The infrastructure should be connected to a switched network. (i.e hubs or repeaters should be avoided) • Depending on network size, a backbone of least 100 Mbps should be used.

2.5

Supported third-party functions The Ascom developed products are designed to work in system provided by different vendors.

5 Mars 2010 / Ver. H

5

System Description Ascom IP-DECT System

3

TD 92375GB

Ascom IP-DECT System The Ascom IP-DECT system is connected via one or several IP-PBXs to the PSTN. For messaging purposes the Ascom IP-DECT system can be connected to one or several Integrated Message Servers (IMS2/UPAC), see 3.4 Messaging in Multiple Master Systems on page 18. The Ascom IP-DECT system have a modular structure that can be modelled as a number of network entities. The network entities defined are: • the entity offering the H323-DECT gateway functionality will be referred to as Radio • the entity acting as the proxy for the IP terminated DECT Portable Devices within the coverage of the associated Radios will be referred to as Master • the entity offering support for finding home location information will be refered to as Mobility Master • the entity offering support for distribution of the DECT identity RFPI will be refered to as Pari Master

3.1

Software Components A Multiple Master system consists of the following entities which are software components which can be activated in an IPBS and IPBL: • • • •

Radio Master Pari Master Mobility Master

For information on how to set these software components, see Installation and Operation Manual for IP-DECT Base Station and IP-DECT Gateway, TD 92579GB. 3.1.1

Pari Master

This software component is responsible for assigning RFPIs, being part of the same external handover domain, to the Radios associated. A Radio will always be given the same RFPI, based on the RFPI-mac-address association. 3.1.2

Mobility Master

The Mobility Master will establish a RAS channel to any associated Mobility Masters, for which roaming agreements has been configured. This ensures scaleablity to a world wide level by distributing the home location master information to local Radios and remote Mobility Masters in the system. 3.1.3

Master

This software component is responsible for the communication to the IP-PBX. Translation between the internal H323 to the DECT Radios and the external protocol (H.323 / SIP) to the IP-PBX is done by this component. A Master is responsible for the DECT Portable Devices that are assigned to it. When the Master has been notified about that a Portable Device is within coverage it makes a registration to the IP-PBX. This registration is maintained by the Master until a notification is received that the Portable Devices access rights has been terminated or the Portable Device has detached. At startup the registration is done only for the Portable Devices that notifies itself with the location registration message.

5 Mars 2010 / Ver. H

6

System Description Ascom IP-DECT System

TD 92375GB

The Master will establish a RAS channel to any associated Mobility Master at startup. All DECT Portable Devices in the HDB are sent to the Mobility Master, to be used in the home location master resolution process. The Master is also responsible for the mapping of keypad information to supplementary PBX features. Some features are handled locally by the Master and some are communicated to the IP-PBX. 3.1.4

Radio

The Radio is a software interface between DECT and H323. Location registration requests that cannot be resolved locally are forwarded to the Master acting as Pari Master. If the Portable Device cannot be resolved locally in the PARI Master, the Mobility Master needs to be involved in the process of resolving the home location master, as it has knowledge of all DECT Portable Devices in the system. Information for authentication of the Portable Device will be sent by the home location master to the Radio. The RAS channel will be established by the Radio for the first Portable Device assigned to a Master and maintained until the last Portable Device assigned to this Master has left the Radio. Thus, the Radio may have several concurrent RAS channels established to different Masters.

3.2

System Layout This section describes examples of three different system layout sizes: • One Master systems, see 3.2.1 One Master Systems on page 7. • Multiple Master systems, see 3.2.2 Multiple Master Systems on page 10. • Multiple Mobility Master systems, see 3.2.3 Multiple Mobility Master Systems on page 15.

3.2.1

One Master Systems

Single site installation See figure 3 on page 8. The system capacity for this layout is: • Up to 1000 users • Max. 1000 IPBS / Pari Master • Max. 100 IPBL / Pari Master This layout may be used for customers with a single site installation. The lines displayed between IP-PBX, Master and Radios are only used to indicate the logical connection between the software modules.

5 Mars 2010 / Ver. H

7

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

master pari master

radio

radio

“many”

radio

RAS connection H.225 Dynamic RAS connection H.225

Figure 3. Single site installation Please note that the figure shows the software components, see figure 4 on page 9. An IPBS/IPBL includes all software components. This means that the same system can be a mix of IPBS and IPBL. In a single site installation one of the IPBS/IPBL will have an active Master and Pari Master software component, and optionally have an active Radio. All others will only have the software component Radio active.

5 Mars 2010 / Ver. H

8

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

master pari master mob b master maste er radio

master

master

master

pa ari master master pari

pa ari master master pari

pa ari master master pari

mob master maste er

mob master maste er

mob m aste er master

radio

radio

radio

Figure 4. Distribution of software components Multiple site installation See figure 5 on page 10. The system capacity for this layout is: • Up to 1000 users • Max. 1000 IPBS / Pari Master • Max. 100 IPBL / Pari Master This layout is choosen if there is no need for local functionality in remote sites. The same layout as in a single site can also be used for customers with an installation on several sites. The sites may have one or several IPBS/IPBL at each site. The IP-PBX and the Pari Master and Master are centrally located (may be one of the sites). With this solution the handset will be able to roam to a different site and it will be possible to receive incoming and make outgoing calls.

5 Mars 2010 / Ver. H

9

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

master pari master

radio

C Central site

radio

radio

Remote site A

radio

radio

Remote site B

Remote site X

RAS connection H.225 Dynamic RAS connection H.225 Radio coverage area

Figure 5. Multiple site installation 3.2.2

Multiple Master Systems

Single site installation See figure 6 on page 11. The system capacity for this layout is: • Up to 1000 users • Max. 1000 IPBS / Pari Master

5 Mars 2010 / Ver. H

10

System Description Ascom IP-DECT System

TD 92375GB

• Max. 100 IPBL / Pari Master This layout may be used for customers with a large single site installation. Load must be distributed over a number of Masters to be able to cope with the load generated from a large number of Portable Devices. It will be possible to do roaming and handover between all Radios. The lines displayed between IP-PBX, Mobility Master, Master and Radios are only used to indicate the logical connection between the software modules. Several Masters are logically connected directly to one or several IP-PBXs. A Master makes RAS registrations to the IP-PBX for the respective Portable Devices within coverage. After registration of a Master to the IP-PBX for a Portable Device, all in- and outgoing speech calls will be routed directly to this Master.

mobmaster IP-PBX

master

master pari master

radio

radio

RAS connection H.225 Dynamic RAS connection H.225 Radio coverage area

Figure 6. Single site installation Please note that the figure shows the software components, see figure 7 on page 12. An IPBS/IPBL includes all software components. This means that the same system can be mixed with IPBS and IPBL. In a single site installation one or several of the IPBS/IPBL will have an active Master software component, only one of the Masters will have an active Pari Master, and one IPBS/IPBL will have an active Mobility Master software component, and optionally have an active Radio. All others will only have the software component Radio active.

5 Mars 2010 / Ver. H

11

System Description Ascom IP-DECT System

TD 92375GB

master

IP-PBX

pari pa ari master master mob master radio

master

master

pari master

pari pa ari master master

mob master mas ste er

mob master masste er

radio

radio

master

master

pari pa ari master master

pari pa ari master master

mobm mobmaster master

mobm mobmaster master

radio

radio

Figure 7. Distribution of software components Multiple site installation See figure 8 on page 13. The system capacity for this layout is: • Up to 1000 users • Max. 1000 IPBS / Pari Master • Max. 100 IPBL / Pari Master This layout is choosen if there is no need for local functionality in remote sites. The same layout as in a single site can also be used for customers with an installation on several sites. The sites may have one or several base stations at each site. The IP-PBX and the PAri Master and Master are centrally located (may be one of the sites). With this solution the Portable Devices will be able to roam to a different site and it will be possible to receive incoming and make outgoing calls.

5 Mars 2010 / Ver. H

12

System Description Ascom IP-DECT System

TD 92375GB

mob master

IP-PBX

master

master pari master

radio

radio

radio

radio

Remote site A

radio Remote site B

Central Centr tral site

RAS connection H.225 Dynamic RAS connection H.225 Radio coverage area

Figure 8. Multiple site installation with central Master Multiple site installation with local functionality See figure 9 on page 14. The system capacity for this layout is: • Up to 1000 users • Max. 1000 IPBS / Pari Master • Max. 100 IPBL / Pari Master This layout is choosen if there is a need for local functionality in remote sites.

5 Mars 2010 / Ver. H

13

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

mob master

master

master pari master

master pari master

radio

radio Central Centr tral site

radio

radio

Remote site A

RAS connection H.225 Dynamic RAS connection H.225 Radio coverage area

Figure 9. Multiple site installation with remote Master Please note that the figure shows the software components, see figure 10 on page 15. An IPBS/IPBL includes all software components. This means that the same system can be mixed with IPBS and IPBL. In site A, one of the IPBS/IPBL will have an active Master and Pari Master software component, and optionally have an active Radio. All others will only have the software component Radio active, see figure 9 on page 14.

5 Mars 2010 / Ver. H

14

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

master pari master mob master mass er radio

master

master

master

pari pa ari master master

pari pa ari master master

pari pa ari master master

mob master masste er

mob master masste er

mob m master aste er

radio

radio

radio

Figure 10. Distribution of software components in remote site A. 3.2.3

Multiple Mobility Master Systems

See figure 9 on page 14. The system capacity for this layout is: • Up to 100 000 users • Max. 1000 IPBS / Pari Master • Max. 100 IPBL / Pari Master This layout is choosen if there is a need for local functionality in a site with several Masters. This layout may be used for customers with large multiple site installations. Load must be distributed over a number of Masters to be able to cope with the load generated from a large number of Portable Devices in one site. It will be possible to do roaming and handover between all Radios within each site. It will be possible to do roaming to all other sites to which roaming agreements exists and it will be possible to receive incoming and make outgoing calls. The lines displayed between IP-PBX, Mobility Master, Master and Radios are only used to indicate the logical connection between the software modules. Several Masters are logically connected directly to one or several IP-PBXs. A Master dynamically makes RAS registrations to the “home” IP-PBX for each of the Portable Devices within its coverage. After registration of a Master to the IP-PBX for a Portable Device, all in- and outgoing speech calls will be routed directly to this Master.

5 Mars 2010 / Ver. H

15

System Description Ascom IP-DECT System

TD 92375GB

mob master

mob master IP-PBX

master pari master

master

radio

radio Site A

IP-PBX

master pari master

master

radio

radio Site B

RAS connection H.225 Dynamic RAS connection H.225 Radio coverage area

Figure 11. Multiple site installation Please note that the figure shows the software components, see figure 12 on page 17. An IPBS/IPBL includes all software components. This means that the same system can be mixed with IPBS and IPBL. In each site one or several of the IPBS/IPBL will have an active Master software component component, only one of the Masters will have an active Pari Master, and one IPBS/IPBL will have an active Mobility Master software component, and optionally have an active Radio. All others will only have the software component Radio active.

5 Mars 2010 / Ver. H

16

System Description Ascom IP-DECT System

TD 92375GB

master

IP-PBX

pari pa ari master master mob master radio

master

master

pari master

pari pa ari master master

mob master mas ste er

mob master masste er

radio

radio

master

master

pari pa ari master master

pari pa ari master master

mobm mobmaster master

mobm mobmaster master

radio

radio

Figure 12. Distribution of software components in site A and B.

3.3

Standby System It is recommended to have Standby devices in an Ascom IP-DECT system. Depending on how the Ascom IP-DECT system is configured, standby devices can be Standby Master, Standby Pari Master, Standby Mobility Master and Backup Sync Master. The Sync Backup Master should be placed close to the primary Sync Master. A good value for RSSI is between -30 and -50 dBm. Other Standby devices (Master, Pari Master) should be placed locally within the same site as the primary device in order to have local functionality. If the primary Pari Master fails, the Standby Pari Master transmits the same RFPI and SARI to the Radios as the primary Pari Master. You should have a Standby Mobility Master placed locally if a remote site has more than one Master, and there is a need for local functionality.

5 Mars 2010 / Ver. H

17

System Description Ascom IP-DECT System

TD 92375GB

IP-PBX

pari master

radio

standby pari master

radio

Figure 13. An Ascom IP-DECT system with a Standby Pari Master.

3.4

Messaging in Multiple Master Systems For messaging purposes the Ascom IP-DECT system can be connected to one or several Integrated Message Servers (IMS2/UPAC). To have messaging functionality for all Portable Devices in a multiple Master system, each Master with Portable Devices assigned must have a connection to an IMS2/UPAC.

mobmaster

pari master

IP-PBX

master

IMS2/UPAC

IMS2/UPAC radio

radio

Figure 14. Messaging in multiple Master systems.

3.5

Broadcast Messaging in Multiple Master Systems Message with broadcast (e.g. fire alarm) must be sent via an IMS2/UPAC connected to the Pari Master since the Pari Master is the only Master that is always connected to all Radios. The message will then be transmitted to all Radios that are connected to the Pari Master. All users, not only the Portable Devices assigned to the Pari Master, within the coverage area will receive the message.

5 Mars 2010 / Ver. H

18

System Description Ascom IP-DECT System

3.6

TD 92375GB

Device Management A Device Manager is an application for managing Portable Devices and chargers in wireless systems. The Device Manager can be connected to one or several Masters. It is also possible to have several Device Managers in the Ascom IP-DECT system.

3.7

Fault Reporting Faults that occur in the Ascom IP-DECT system are shown locally in the faulty IPBS/IPBL. The faults can be forwarded to a central point (the Master) in the Ascom IP-DECT system. The faults can also be forwarded to the Ascom’s Messaging system and to an external SNMP manager.

3.8

Load Balancing Load balancing can be used in an Ascom IP-DECT system when the number of Portable Devices exceeds what an IP-PBX is able to register. When load balancing, the traffic is distributed over several IP-PBXs which can be done in two ways using: • fixed connections for users on each Master towards multiple IP-PBXs. • dynamic connection for users on each Master towards IP-PBX network using DNS services. For more information about load balancing, see Installation and Operation Manual for IPDECT Base Station and IP-DECT Gateway, TD 92579GB.

5 Mars 2010 / Ver. H

19

System Description Ascom IP-DECT System

3.9

TD 92375GB

Synchronization Synchronization within the Ascom IP-DECT system is done with the following two methods: • Air synchronization (IPBS) • Ring synchronization (IPBL) • Air and ring synchronization combined

3.9.1

Air Synchronization

Each IPBS must be placed within the air sync coverage area of at least one other base station. Since the sync radius is somewhat larger than the cover radius it is often enough to consider the speech coverage when placing the base stations. Always ensure that all IPBS are able to synchronize with, preferably two, but at least one other base station. When IPBSs and RFPs are used in the same system, all RFPs are sync Masters. First the IPBSs try to synchronize to RFPs and then to other IPBSs. The RFPs receives their sync from the IPBLs. Figure 1.

Air Sync Coverage

005

Speech Coverage

Figure 15. Air- and speech sync radius. 3.9.2

Ring Synchronization

Each synchronization port sends and receives synchronization signals. Each IPBL has two ports (in/out) for ring synchronization and two ports (in/out) for reference synchronization. The ring synchronization can be made in two different ways: • Redundant (preferred) • Non redundant Each synchronization ring dynamically assigns a sync master.

5 Mars 2010 / Ver. H

20

System Description Ascom IP-DECT System

TD 92375GB

3.10 Channel Distribution When a handset is used for speech, message, or alarm it always occupies one channel. However, when a handset is used for speech it can send or receive a message or an alarm on the same channel. 3.10.1 BS3x0 Connected to the IPBL

IPBL

Speech calls

Messages to/from handset

Alarm from handset

Broadcast

The BS3x0 that is connected to the IPBL has in total twelve channels. One channel is reserved for broadcast messages. Alarm from handset can occupy eleven channels. Messages to/from handsets can occupy ten channels but only eight speech calls can be handled simultaneous, see figure 16.

1 2 3 4 5 6 7 8 9 10 11 12

005

LAN

Figure 16. Channel distribution in the BS3x0 connected to the IPBL. This means that even if a BS3x0 reports that it is busy i.e. fully occupied with speech calls and/or messaging, there are always channels free for alarm from handset and broadcast messages. 3.10.2 IPBS The IPBS has in total twelve channels. One channel is reserved for broadcast messages and two channels are reserved for synchronization. Alarm from handset can occupy nine channels but only eight speech and/or messaging can be handled simultaneously, see figure 17.

5 Mars 2010 / Ver. H

21

System Description Ascom IP-DECT System

Speech and Messaging

Alarm from handset

Sync. bearer

Broadcast

TD 92375GB

1 2 3 4 5 6 7 8 9 10 11 12

006

LAN

Figure 17. Channel distribution in the IPBS. This means that even if a IPBS reports that it is busy i.e. fully occupied with speech calls and/or messaging, there are always channels free for alarm from handset and broadcast messages.

3.11 Ascom IP-DECT System Management 3.11.1 On Site Management The IPBS and IPBL are managed using a web GUI accessed over the LAN. 3.11.2 Remote Management The IPBS and IPBL can be managed over the Internet using a VPN client. Remote management is also possible by using the ESS module. For more information, see Function Description, Remote Management, TD 92257GB. 3.11.3 IP Administration Security All IP administration is based on secure IP (HTTPS). All access to the IPBS and IPBL are password protected in order to prevent unauthorised access. 3.11.4 Software Upgrade The IPBS and IPBL have support for software download and it is possible to do a software upgrade using the web interface. It also has support for automatic firmware update from a web server.

5 Mars 2010 / Ver. H

22

System Description Ascom IP-DECT System

4

TD 92375GB

VoIP Signalling Protocols Two of the protocols used for VoIP signalling are H.323 and SIP. H.323 was the first standard and is in fact a set of protocols designed to enable multimedia traffic in single LANs. One protocol of many in the set of protocols defined in H.323, is H.450, which is a series of protocols which defines Supplementary Services for H.323. Like H.323, SIP can be used for VoIP but while H.323 is ISDN-based (Q. 931 and earlier H series), SIP is text-based. As opposed to H.323 which uses Abstract Syntax Notation number One (ASN.1), SIP encodes its messages as text, similar to HTTP and SMTP.

4.1

H.323 H.323 was developed by the International Telecommunications Union (ITU) and was designed from a telecommunications perspective. Ratified in 1996 it has become a defacto choice for interoperability among VoIP equipment. It is a standard that provides specification for computers, equipment, and services for multimedia communication over networks that do not provide a guaranteed QoS. H.323 equipment can carry real-time video, audio, and data, or any combination of these elements. Included in the H.323 standard are H.225, H.245 and the IETF protocols RTP and RTCP, with additional protocols for call signalling, data and audiovisual communications. H.323 products and services offer the following benefits to users: • Products and services developed by multiple manufacturers under the H.323 standard can interoperate without platform limitations. H.323 conferencing clients, bridges, servers, and gateways support this interoperability. • H.323 provides multiple audio and video codecs that format data according to the requirements of various networks, using different bit rates, delays, and quality options. Users can choose the codecs that best support their computer and network selections.

4.1.1

H.450 Supplementary Services for H.323

H.450 is a series of protocols which are used to exchange signalling information to control the supplementary services such as, Call Transfer, Call Diversion, Call Waiting etc. over a LAN.

4.2

Session Initiation Protocol (SIP) SIP is an application layer control (signalling) protocol for creating, modifying, and terminating sessions with one or more participants. These sessions include Internet multimedia conferences, Internet telephone calls and multimedia distribution. SIP is designed as part of the IETF standards. SIP itself is not sufficient to set up a call and other IETF protocols such as RTP and SDP are required to support a VoIP call. However, the functionality and operation of SIP does not depend on any of these protocols.

5 Mars 2010 / Ver. H

23

System Description Ascom IP-DECT System

5

TD 92375GB

Related Documents System Planning, Ascom IP-DECT System

TD 92422GB

Installation and Operation Manual for IP-DECT Base Station and IP-DECT Gateway

TD 92579GB

Configuration Notes for Cisco Call Manager in Ascom IP-DECT System

TD 92424GB

Configuration Notes for Aastra MX-ONE in Ascom IP-DECT System

TD 92637GB

Configuration Notes for Ascom VoIP Gateway in Ascom IP-DECT System

TD 92642GB

Configuration Notes for FXO in Ascom IP-DECT System

TD 92529GB

Data Sheet, IP-DECT Base Station

TD 92370GB

Data Sheet, IP-DECT Gateway

TD 92430GB

Installation and Operation Manual, Integrated Message Server (IMS2)

TD 92586GB

Installation and Operation Manual, Alarm Management Server (AMS)

TD 92047GB

Installation and Operation Manual, Enhanced System Service (ESS)

TD 92253GB

Function Description, Remote Management

TD 92257GB

Data sheet, Integrated Message server (IMS)

TD 92585GB

Data Sheet, Enhanced System Service (ESS)

TD 92250GB

System Description, Unite

TD 92243GB

5 Mars 2010 / Ver. H

24

System Description Ascom IP-DECT System

TD 92375GB

Document History For details in the latest version, see change bars in the document.

Version

Date

A

2006-05-24 First released version.

B

2006-08-15 General improvments.

C

2007-01-15 New document structure.

D

2007-04-20 IP-DECT Gateway added. 2007-10-25 • Chapter 3.9.2 Ring Synchronization on page 20 updated. • Appendix A Messaging Capacity updated.

E

Description

F

2009-02-02 Major update of the document with the introduction of the Multiple Master system concept.

G

2009-04-15 Added some information about broadcast messaging and device management. Updated Appendix A: Messaging Capacity.

H

2010-03-05 Minor changes.

5 Mars 2010 / Ver. H

25

System Description Ascom IP-DECT System

TD 92375GB

Appendix A: Messaging Capacity A.1

Alarm Messages from Cordless Handset Time until received in the Unite system:

A.2

~ 2 sec

No Highspeed Data to Cordless Handset 9d24

A.2.1

Incoming Messages to Cordless Handset 9d24 (version 3.0 or later)

The time for a message to be delivered differ dependent on how many characters the message contain and if it is delivered to a single handset or a group of handsets. Number of message characters:

No of Cordless For IPBL: Handsets: Time in seconds until one handset is paged:

For IPBS: Time in seconds until one handset is paged:

20 characters

1

~4

~3

120 characters

1

~5

~3

240 characters

1

~6

~4

500 characters

1

~9

~7

Number of message characters:

No of Cordless For IPBL: Handsets: Time in seconds until all handsets are paged:

For IPBS: Time in seconds until all handsets are paged:

20 characters

1 10 30 100

~4 ~6 ~ 14 ~ 43

~3 ~4 ~ 11 ~ 32

120 characters

1 10 30 100

~5 ~7 ~ 17 ~ 56

~3 ~4 ~ 13 ~ 39

A.2.2

Incoming Messages to Cordless Handsets in a Broadcast Group

Number of message characters

No of Cordless For IPBL: Handsets: Time in seconds until the group is paged:

For IPBS: Time in seconds until the group is paged:

20 characters

Unlimited

~4

~3

120 characters

Unlimited

~4

~4

240 characters

Unlimited

~7

~7

500 characters

Unlimited

~ 14

~ 13

5 Mars 2010 / Ver. H

26

System Description Ascom IP-DECT System

A.3

TD 92375GB

Highspeed Data to Cordless Handset d62

A.3.1

Incoming Messages to Cordless Handset d62

The time for a message to be delivered differ dependent on how many characters the message contain and if it is delivered to a single handset or a group of handsets. Number of message characters:

No of Cordless For IPBL: Handsets: Time in seconds until one handset is paged:

For IPBS: Time in seconds until one handset is paged:

20 characters

1

~4

~3

120 characters

1

~5

~3

240 characters

1

~6

~3

500 characters

1

~9

~3

Number of message characters:

No of Cordless For IPBL: Handsets: Time in seconds until all handsets are paged:

For IPBS: Time in seconds until all handsets are paged:

20 characters

1 10 30 100

~4 ~6 ~ 14 ~ 43

~3 ~3 ~6 ~ 23

120 characters

1 10 30 100

~5 ~7 ~ 17 ~ 56

~3 ~3 ~9 ~ 27

A.3.2

Incoming Messages to Cordless Handsets in a Broadcast Group

Number of message characters

No of Cordless For IPBL: Handsets: Time in seconds until the group is paged:

For IPBS: Time in seconds until the group is paged:

20 characters

Unlimited

~4

~3

120 characters

Unlimited

~4

~4

240 characters

Unlimited

~7

~7

500 characters

Unlimited

~ 14

~ 13

5 Mars 2010 / Ver. H

27

System Description Ascom IP-DECT System

TD 92375GB

Appendix B: Ascom Technical Documentation This appendix explains the technical documentation structure and gives a description of each document type.

System documents

Function Description (FD)

1. System Description (SD)

(Describes functions on system- and product level, and requirements to achive them.)

2. System Planning (SP) 3. System Installation (SI)

Configuration Manual (CM) (Settings for Products)

Configuration Notes (CN)

Product documents

(Settings for interconnection with other products)

Data Sheet (DS)

Installation Guide (IG)

User Manual (UM)

(Portable Devices, PC software)

Installation and Operation Manual (IOM)

(Software)

(Fixed units)

On-line Help (OH)

Quick Reference Guide (QRG)

Assembly Card (AC) (Products)

Service documents

(Portable Devices only)

Repair Manuals (RM) 1st, 2nd and 3rd line

(Portable Devices, Fixed Units)

Figure 18. Document structure

System Description (SD) Gives a general description of the system philosophy with basic functions and general configuration possibilities associated to functions. Target groups: is relevant for system responsible at the customer site, sales department, training department, project manager or whoever wants to know the basics of the system. System Planning (SP) Is to be read after taking part of the System Description. It describes different functions, possible technical system solutions and deals with factors that can affect the installation. Target groups: technical engineers planning a system.

5 Mars 2010 / Ver. H

28

System Description Ascom IP-DECT System

TD 92375GB

System Installation (SI) Primarily explains system dependent aspects to be considered at system installation and gives an overview of how to install the system. Target groups: technical engineers planning the system and technicians installing it Function Description (FD) Gives all relevant information, requirements and configuration notes, concerning functions in system and products, for example positioning, interactive messaging etc. Target groups: see under System Description section. Configuration Manual (CM) Describes the complete configuration for a specific product. Target groups: installation-, service-, support technicians and system responsible. Configuration Notes (CN) Describes configuration required for two or more interconnected products to achieve best performance or specific functions. Is a complement to other product specific documents. Target groups: installation-, service-, support technicians and system responsible. Data Sheet (DS) Technical data of a software/products etc. It includes a short list of features, applications and possibly extended functions with other software/products. Target groups: end customer, system responsible, technical engineers and sales department. Installation Guide (IG) Describes how to install any fixed units in the system. Target groups: installation- and service personnel. Installation and Operation Manual (IOM) Describes how to install and operate different PC software programmes. In many cases complemented with or replaced by on-line help or CD. Target groups: service engineer or administration responsible of the end user system. Quick Reference Guide (QRG) This document is available for Portable Devices only. It contains a concise, how to use description, and is normally distributed together with the Portable Device. Target groups: user of the portable device for quick learning of included functions. User Manual (UM) For Portable Devices: Is a complement to the QRG. It gives a thorough description of the specific functions and how to use the product for example a Transceiver. Target groups: responsible for handling the administration and distribution of pocket units at the end customer site, or anyone interested to get deeper usage knowledge. For PC Software: If it is preferable to separate installations and operations a UM describes how the end user operates the software. In many cases UM is complemented with on-line help. Target groups: End user. On-Line Help (OH) Gives help and information via the PC screen.

5 Mars 2010 / Ver. H

29

System Description Ascom IP-DECT System

TD 92375GB

Repair Manual (RM) For service and repair on some of the Ascom products. The document describes the repair of a product defined by one of three levels: 1st Line Repair Mechanical/cosmetic repair such as change of housing etc. and upgrade of software. No advanced soldering knowledge is needed but test equipment to verify functionality/ quality after repair is needed. (Could also include test /programming equipment for field/ onsite service). 2nd Line Repair Electrical repair on PCB level, changing of PCB:s, minor electrical repair of PCB level and change of easily soldered parts. Test equipment to verify functionality/quality after repair is needed. 3rd Line Repair Advanced electrical repair on PCB level. Major knowledge in soldering technique is needed. Changing of SMD, BGA circuits etc. Advanced test equipment and equipment to verify functionality/quality after repair is needed. Target groups: service- and support technicians. Assembly Card Leaflet packed together with a product. Shows either how to mount or assembly some part, for example a battery back, or how to start up a product. Old documents:

5 Mars 2010 / Ver. H

II = Installation Instructions AA = Alignment and Adjustment SAG = Setup & Application Guide ED = Electrical Diagram CD = Circuit Description CL = Component Layout

30