Supplementary instructions Sigmas with hygienic pump head

Supplementary instructions Sigmas with hygienic pump head EN Two sets of operating instructions are required for the safe, correct and proper operat...
Author: Buddy Austin
0 downloads 0 Views 2MB Size
Supplementary instructions Sigmas with hygienic pump head

EN

Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: This set of supplementary instructions and the corresponding "Operating instructions for the diaphragm motor driven metering pump Sigma". Both sets of operating instructions are only valid when read together. Please carefully read these operating instructions before use. · Do not discard. The operator shall be liable for any damage caused by installation or operating errors. The latest version of the operating instructions are available on our homepage.

Part no. 986047

BA SI 067 10/15 EN

Table of contents

Table of contents 1

Sigma 1........................................................................................... 3 1.1 1.2 1.3 1.4

2

Sigma 2 Performance Data..................................................... Wetted Materials..................................................................... Dimensional Drawings of Sigma 2.......................................... Spare Parts Lists for Sigma 2.................................................

7 8 8 9

Sigma 3......................................................................................... 10 3.1 3.2 3.3 3.4

2

3 4 5 6

Sigma 2........................................................................................... 7 2.1 2.2 2.3 2.4

3

Sigma 1 Performance Data..................................................... Wetted Materials..................................................................... Dimensional Drawings of Sigma 1.......................................... Spare Parts Lists for Sigma 1.................................................

Sigma 3 Performance Data................................................... Wetted Materials................................................................... Dimensional Drawings of Sigma 3........................................ Spare Parts Lists for Sigma 3...............................................

10 11 12 13

4

Intended Use................................................................................. 14

5

Assembly of the Hygienic Pump Head.......................................... 15

6

Notes on Cleaning Metering Pumps with Hygienic Pump Head.... 16

7

EHEDG Certificate......................................................................... 18

Sigma 1

1

Sigma 1

1.1 Sigma 1 Performance Data S1Ba with hygienic pump head at 50 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

ml/stroke

Strokes/min

m WS

DN

12035

10

31

3.5

143

1.15

10

12017

10

16

3.6

73

0.7

10

10050

10

43

3.5

205

1.15

10

10044

10

39

4.5

143

1.8

10

10022

10

21

4.7

73

1.8

10

07065

7

58

4.7

205

1.8

10

07042

7

38

8.7

73

1.8

15

04120

4

108

8.8

205

1.8

15

04084

4

76

8.8

143

1.8

15

All figures are guideline figures for water at 20 °C. The priming lift applies to clean, moist valves, an empty suction line and empty liquid end - with correct installation (valve springs reduce the values). S1Ba with hygienic pump head at 60 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

ml/stroke

Strokes/min

m WS

DN

12035

10

37

3.5

115

1.15

10

12017

10

19

3.6

115

0.7

10

10044

10

47

4.5

180

1.8

10

10022

10

25

4.7

180

1.8

10

07042

7

46

8.7

180

1.8

15

04084

4

91

8.8

180

1.8

15

All figures are guideline figures for water at 20 °C. The priming lift applies to clean, moist valves, an empty suction line and empty liquid end - with correct installation (valve springs reduce the values).

3

Sigma 1 S1Cb with hygienic pump head Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

ml/stroke

Strokes/min

m WS

DN

12035

10

37

3.5

172

1.15

10

12017

10

19

3.6

88

0.7

10

10050

10

42

3.5

200

1.15

10

10044

10

47

4.5

172

1.8

10

10022

10

25

4.7

88

1.8

10

07065

7

56

4.7

200

1.8

10

07042

7

46

8.7

88

1.8

15

04120

4

106

8.8

200

1.8

15

04084

4

91

8.8

172

1.8

15

All figures are guideline figures for water at 20 °C. The priming lift applies to clean, moist valves, an empty suction line and empty liquid end - with correct installation (valve springs reduce the values).

1.2 Wetted Materials

4

Dosing head

Valve housing

Seals / dia‐ phragms

Inner part

1.4404

1.4435

PTFE

1.4404/EPDM

Sigma 1

1.3 Dimensional Drawings of Sigma 1 Dimensional drawing of Sigma 1, S1Cb with hygienic pump head

P_SI_0157_SW

Fig. 1: Dimensional drawing of Sigma 1, S1Cb with hygienic pump head - dimensions in mm

5

Sigma 1

1.4 Spare Parts Lists for Sigma 1 Sigma 1 with hygienic pump head

A

A

61_05-104_01_45

Item

Type Quantity Article

Order no.

104

A, B

1.000

Hyg. connection set TCVC DN10

1035924

104

C

1.000

Hyg. connection set TCVC DN15

1035945

121

A-C

2.000

Hyg. valve seal TCVC

1035921

122

A-C

2.000

Hyg. valve inner part EPDM with seal

1038124

123

A, B

1.000

Hyg. valve top part TCVC DN10

1035919

123

C

1.000

Hyg. valve top part TCVC DN15

1035933

124

A, B

1.000

Hyg. valve bottom part TCVC DN10

1035920

124

A

1.000

Hyg. valve bottom part TCVC DN15

1035944

125

A- B

2.000

Hyg. clamp connection TRICLAMP TCVC

1035923

200

A

1.000

Diaphragm 70 x 32 -M6 PTFE

1010279

200

B

1.000

Diaphragm 70 x 37 -M6 PTFE

1010282

200

C

1.000

Diaphragm 77.0x 33.5 -M5 PTFE

1000250

202

A, B

4.000

Cyl. screw DIN 912 M 5x 80

468080

202

C

6.000

Cyl. screw DIN 912 M 5x 80

468080

6

Sigma 2

2

Sigma 2

2.1 Sigma 2 Performance Data S2Ba with hygienic pump head at 50 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

psi

l/h

gph

ml/stroke

Strokes/ min

m WS

DN

16130

10

145

117

31.0

9.87

198

1.9

15

16090

10

145

81

21.3

10.20

132

1.9

15

16050

10

145

45

11.8

10.19

73

1.9

15

07220

7

100

180

47.6

22.73

132

2.8

20

07120

7

100

115

30.4

26.28

73

2.8

20

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation. S2Ba with hygienic pump head at 60 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

psi

l/h

gph

ml/stroke

Strokes/ min

m WS

DN

16090

10

145

97

25.5

10.20

190

1.9

15

16050

10

145

53

14.0

10.19

190

1.9

15

07220

7

100

216

56.9

22.73

280

2.8

20

07120

7

100

137

36.2

26.28

280

2.8

20

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation. S2Cb with hygienic pump head Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

psi

l/h

gph

ml/stroke

Strokes/ min

m WS

DN

16130

10

145

118

31.3

9.87

200

1.9

15

16090

10

145

98

25.9

10.20

160

1.9

15

16050

10

145

55

14.5

10.19

90

1.9

15

07220

7

100

218

57.7

22.73

160

2.8

20

07120

7

100

142

37.5

26.28

90

2.8

20

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation.

7

Sigma 2

2.2 Wetted Materials Dosing head

Valve housing

Seals / dia‐ phragms

Inner part

1.4404

1.4435

PTFE

1.4404/EPDM

2.3 Dimensional Drawings of Sigma 2 Dimensional drawing of Sigma 2, S2Cb with hygienic pump head

P_SI_0158_SW

Fig. 2: Dimensional drawing of Sigma 2, S2Cb with hygienic pump head - dimensions in mm

8

Sigma 2

2.4 Spare Parts Lists for Sigma 2

A

A

61_05-104_01_46

Item

Type Quantity Article

Order no.

104

A

1.000

Hyg. connection set TCVC DN15

1035945

104

B

1.000

Hyg. connection set TCVC DN20

1035948

121

A, B

2.000

Hyg. valve seal TCVC

1035921

122

A,-C

2.000

Hyg. valve inner part EPDM with seal

1038124

123

A

1.000

Hyg. valve top part TCVC DN15

1035933

123

B

1.000

Hyg. valve top part TCVC DN20

1035950

124

A

1.000

Hyg. valve bottom part TCVC DN15

1035944

124

B

1.000

Hyg. valve bottom part TCVC DN20

1035949

125

A, B

2.000

Hyg. clamp connection TRICLAMP TCVC

1035923

200

A

1.000

Diaphragm 86.5x 46.0 P

792495

200

B

1.000

Diaphragm 123.5x 75.0 P

792496

202

A

6.000

Hexagon screw DIN 931 M 6x 80

468166

202

B

6.000

Hexagon screw DIN 931 M 6x 90

468167

9

Sigma 3

3

Sigma 3

3.1 Sigma 3 Performance Data S3Ba with hygienic pump head at 50 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

ml/stroke

Strokes/min

m WS

DN

120145

10

127

29.3

72

2.8

20

120190

10

178

28.8

103

2.8

20

120270

10

205

23.8

144

2.8

20

120330

10

217

20.0

180

2.8

20

070410

7

335

77.5

72

4.2

25

070580

7

446

72.1

103

4.2

25

040830

4

616

71.3

144

4.2

25

041030

4

761

70.4

180

4.2

25

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation. S3Ba with hygienic pump head at 60 Hz operation Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

gph

ml/stroke

Strokes/min

m WS

DN

120145

10

151

39.9

29.3

86

2.8

20

120190

10

215

56.7

28.8

124

2.8

20

120270

10

247

65.2

23.8

173

2.8

20

070410

7

400

105.7

77.5

86

4.2

25

070580

7

537

141.7

72.1

124

4.2

25

040830

4

741

195.6

71.3

173

4.2

25

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation.

10

Sigma 3 S3Cb with hygienic pump head Type

Minimum pump capacity at maximum back pressure

Maximum stroke rate

Priming lift

Connector size

bar

l/h

gph

ml/stroke

Strokes/min

m WS

DN

120145

10

158

41.8

29.3

86

2.8

20

120190

10

208

54.9

28.8

124

2.8

20

120270

10

257

67.8

23.8

173

2.8

20

070410

7

419

110.6

77.5

86

4.2

25

070580

7

519

137.2

72.1

124

4.2

25

040830

4

771

203.6

71.3

173

4.2

25

All figures are guideline figures for water at 20 °C. The priming lift applies to a filled suction line and filled liquid end - with correct installation.

3.2 Wetted Materials Dosing head

Valve housing

Seals / dia‐ phragms

Inner part

1.4404

1.4435

PTFE

1.4404/EPDM

11

Sigma 3

3.3 Dimensional Drawings of Sigma 3 Dimensional drawing of Sigma 3, S3Cb with hygienic pump head

P_SI_0159_SW

Fig. 3: Dimensional drawing of Sigma 3, S3Ca with hygienic pump head - dimensions in mm

12

Sigma 3

3.4 Spare Parts Lists for Sigma 3

A

A

61_05_104_01_47

Item

Type Quantity Article

Order no.

104

A

1.000

Hyg. connection set TCVC DN20

1035948

104

B

1.000

Hyg. connection set TCVC DN25

1035958

121

A, B

2.000

Hyg. valve seal TCVC

1035921

122

A-C

2.000

Hyg. valve inner part EPDM with seal

1038124

123

A

1.000

Hyg. valve top part TCVC DN20

1035950

123

B

1.000

Hyg. valve top part TCVC DN25

1035955

124

A

1.000

Hyg. valve bottom part TCVC DN20

1035949

124

B

1.000

Hyg. valve bottom part TCVC DN25

1035956

125

A, B

2.000

Hyg. clamp connection TRICLAMP TCVC

1035923

200

A

1.000

Diaphragm 123.5x 75 - M10

1004604

200

B

1.000

Diaphragm 178 x 132 - M10

1002835

202

A

6.000

Hexagon screw DIN 931 M 6x100

468168

202

B

8.000

Hexagon screw DIN 931 M 8x110

1005296

13

Intended Use

4

Intended Use Supplementary information to the 'Intended Use' in the "Operating Instruc‐ tions for Sigma": n

The pump is only intended for use in sealed systems with CIP (cleaning in place) in the hygienic sector.

(EHEDG-certified, type EL Class I)

14

Assembly of the Hygienic Pump Head

5

Assembly of the Hygienic Pump Head Select the hygienic pump head by its identity code under "Dosing head design" - "H hygienic pump head" (only with stainless steel pump heads). The hygienic head is supplied assembled on the pump (welded assembly (item 100)); the valves (item 104) are packed in bags. n n

Assemble the pump so that the EHEDG symbol on the hygienic pump head is legible. Fit the valves (item 104) as shown on the Figure – Make sure that the flat inner side of the valves is always facing downwards as well as the O-ring on the fastening body (item 122) - see Figure

61_05-104_01_46-04x01_B2

15

Notes on Cleaning Metering Pumps with Hygienic Pump Head

6

Notes on Cleaning Metering Pumps with Hygienic Pump Head

General

Metering pumps of the Sigma product range, fitted with hygienic head, are used to pump and meter high-grade, hygienically flawless and microbio‐ logically sensitive liquids. They therefore need to be thoroughly cleaned at the end of a production process and be absolutely clean and free of germs that could be harmful to the product, or even pathogens, at the start of a new production process. ProMinent® therefore recommends including the metering pumps in an HACCP and/or in-house hygiene scheme.

Certification

The cleaning-friendly construction of ProMinent® metering pumps with hygienic pump head in compliance with the requirements of the EHEDG (www.ehedg.org) has been confirmed by the TU Munich-Weihenstephan Certification Office and correspondingly certified (EHEDG Type EL class I).

Inclusion in CIP (Cleaning In Place)

ProMinent® recommends including metering pumps with hygienic pump head in the CIP (Cleaning in Place) process. This means that the pump is cleaned in a circular and/or continuous process without having to be dis‐ mantled. It involves the following steps, depending on the level of impurities: 1 - Pre-flushing with water 2 - Flushing with alkali 3 - Interim flushing with water 4 - Flushing with acid 5 - Flushing with clear water

Flow velocity

Fundamental prerequisite for a successful CIP (cleaning in place) is a tur‐ bulent flow at a minimum flow velocity of 1.5 m/s based on the pipe diam‐ eter of the pump inlet. Should this flow velocity not be reached due to the inherent capacity of the pump type, then a centrifugal pump should be installed upstream as a booster pump. However, never exceed the maximum permitted priming pressure on the suction side - see "Technical Data".

Stroke rate and stroke length

The metering pump should run at a minimum stroke rate of 72 strokes/min and at 100% stroke length during CIP (Cleaning in Place) to ensure that liquid flows perfectly through the hygienic pump head.

Drainage of residual liquid / Self-draining

Tightly sealed non-return valves are fitted in ProMinent® metering pumps with hygienic pump head. That is why the dosing head needs to be man‐ ually drained after the CIP (Cleaning in Place) step by opening the clamps and/or using compressed air to ensure that any residual liquid is drained. In doing so it is imperative that you ensure using fittings and pipework that no cleaning solution can enter parts of the system that carry product. When using compressed air, use appropriate fittings and pipework to ensure that any residual liquid is fully blown out. Make sure that the pump is at a standstill when doing so.

Materials of wetted parts

The following wetted materials are used in ProMinent® metering pumps with hygienic pump head:

16

Notes on Cleaning Metering Pumps with Hygienic Pump Head

A

A

61_05_104_01_47

Fig. 4

Item. no.

Wetted materials

100

Stainless steel 1.4404

104, 122, 123

Stainless steel 1.4435

200

PTFE

125

Gylon BIO PRO® (PTFE material)

Part of 122 Gylon BIO gies

PRO®

EPDM, if item 122 has a seal is a registered trademark of Garlock Sealing Technolo‐

Chemical resistance

Check the resistance of the wetted parts to the CIP (Cleaning in Place) media used in detail.

Temperature resistance

ProMinent® metering pumps with hygienic pump head can be exposed to temperatures of max. 120 °C at 2 bar for a maximum of 15 minutes.

Process connections

ProMinent® metering pumps with hygienic pump head are supplied as standard with welded ends in compliance with DIN 11850 Range 2. The pumps are dismantled by loosening the BIO CONNECT® clamp connec‐ tion by means of which the valves can be separated into a top and bottom half. Note this when designing the connecting pipework. Connection adapters can be customised and fitted at any time.

Cleaning without CIP (Cleaning in place)

Adapt the cleaning process if no CIP-compatible connections (e.g. milk pipe connectors DIN 11851, hose connectors, Clamp DIN 32676) are used or only used to a limited extent.

17

EHEDG Certificate

7

18

EHEDG Certificate

19

ProMinent GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany Telephone: +49 6221 842-0 Fax: +49 6221 842-419 Email: [email protected] Internet: www.prominent.com Heidelberg, 2, en_GB

© 2010