INSTALLATION & OPERATION electronic 1-tank thru 6-tank ton container scales with 1- or 2-Channel Solo Indicator d ed te at ra br alliib ca y c ry or to ct ac ffa SOLO 1000-1

T ET N NE

4 34 23 1 12

__________________ s/n s/n __________________

W OW FLLO E F CE RC OR F FO

1-CHANNEL

SOLO 1000-2

1 #1 E TT # N NE 2 #2 E TT # N NE

4 34 23 1 12 8 78 67 1 16

W OW FLLO E F CE RC OR F FO

2-CHANNEL

n:: on V Veerrssiio

FORCE FLOW F FL LO OQ QU U II P P

D CD LC 6L 96 O9 RO P PR

A SA US 0 U 20 52 45 94 A 9 CA d,, C orrd co nc on Co Avvee,, C neetttt A urrn Bu D B 0--D 50 11115 3 7113 67 6--6 86 68 5--6 25 92 axx:: 9 F Fa 3 23 72 67 3--6 93 89 0--8 00 80 11--8 m om co w..c ow ceeffllo orrc @ffo o@ nffo m // IIn om co w..c ow ceeffllo orrc w..ffo ww w ww w cw O..ttc SO NS ON TO RT VR CV O\\C LO OL SO NS ON TO M\\T &M O& 4\\O T4 F:: T EF R RE

dff)) 0..ppd 00 S0 ((S

INCLUDES MODELS:

ELECTRONIC TON CONTAINER SCALES with SOLO 1000 DIGITAL INDICATORS

INDICATORS:

PLATFORM:

1000-1 (1-Channel) 1000-2 (2-Channel) 1-TANK SCALE:

DR40 (Metric DR20K)

4,000 lbs. (2,000 kg)

2-TANK SCALE:

DR80 (Metric DR40K)

8,000 lbs. (4,000 kg)

3-TANK SCALE:

DR120 (Metric DR60K)

12,000 lbs. (6,000 kg)

4-TANK SCALE:

DR160 (Metric DR80K)

16,000 lbs. (8,000 kg)

5-TANK SCALE:

DR200 (Metric DR100K)

20,000 lbs. (10,000 kg)

6-TANK SCALE:

DR240 (Metric DR120K)

24,000 lbs. (12,000 kg)

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 WWW.FORCEFLOW.COM

FORCE FLOW F LOQ U I P

/

[email protected]

REF: T4\O&M\TONSOLO\MODELNOS.tcw

(S0A.pdf)

FORCE FLOW

HELP HOTLINE 1-800-893-6723 www.forceflow.com [email protected]

NOTES:

INDEX SOLO 1000 Indicator with CHLOR-SCALE 1- thru 6-TANK

SECTION S.1.000 YOU ARE HERE !

INSTALLATION OF 1-TANK SCALE PLATFORM: S.1.101 Dimensioned Installation Drawing S.1.102 1-Tank Platform Installation Instructions INSTALLATION OF 2-TANK SCALE PLATFORM: S.1.121 Dimensioned Installation Drawing S.1.122 2-Tank Platform Installation Instructions INSTALLATION OF 3- thru 6- TANK SCALE PLATFORM: S.1.131 3-Tank Dimensioned Installation Drawing S.1.132 4-Tank " (etc) S.1.133 5-Tank " (etc) S.1.134 6-Tank " (etc) S.1.135 Platform Installation Instructions S.1.136 Pad Placement for Multiples INSTALLATION OF LOAD CELL S.1.141 Load Cell Data Sheet S.1.142 Load Cell Assembly Drawing INSTALLATION OF INDICATOR S.1.201-1 1-Channel Indicator Wiring & Plumbing Drawing S.1.201-2 2-Channel " (etc) S.1.202-1 1-Channel Instructions: Power; Load Cell & Tare Adjust; 4-20mA S.1.202-2 2-Channel " (etc) S.1.203-1 1-Channel Instructions: Set Point; Surge & Static Protection S.1.203-2 2-Channel " (etc) INSTALLATION CHECK LISTS S.1.301 Installation Check List S.1.305 Start-Up Check List (Portable or Fixed Tanks)

S.2.000

SCALE OPERATION: S.2.101 Tank Scale Operation OPTIONAL ALARM SET POINT: S.2.301-1 1-Channel Alarm Set Point Configuration S.2.301-2 2-Channel Alarm Set Point Configuration

FORCE FLOW F LO Q U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected] REF: T4\O&M\TONSOLO\Y45.tcw etc (Y45.pdf etc)

MODEL NUMBERS (for Frame & Load Cell) DR40 (4000 lbs) DR20K (2000 kgs) 45" (1143mm)

MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR000-1 2-Channel SR000-2

SOLO 1000

1234 FORCE FLOW F L O Q U I P

28" (711mm)

___________ Model Number of Indicator (Lbs or Kgs _____) ___________ Model Number of Scale Frame ___________ Feet of Cable per Scale (20' Std)

FRAME TONGUE

80" (2032mm)

LOAD CELL

TON CONTAINER

30" (762mm)

37" (940mm)

8" (203mm)

7" (178mm)

44" (1118mm)

S.1.101

FORCE FLOW

IMPORTANT: Position the Load Cell so that it is parallel with the scale frame. Read the "Installation" section carefully for proper placement of the frame.

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

F L O Q U I P

File: T4\O&M\TONSOLO\SOLOSGL.tcw (S02.pdf) (WEB: TON1SOLO.pdf)

31" (778mm)

Drawn by:

ELECTRONIC SINGLE TANK SCALE CHLOR-SCALE with SOLO 1000 INDICATOR (4000 lb. or 2000 kg. Capacity)

Date:

SLP 09/01/95

Revised: Scale:

NONE

Drawing Number

30281

INSTALLATION

MODEL DR40 (Metric Model Number DR20K)

with SOLO 1000 INDICATOR One (1) Tank Scale (4,000 lb. Capacity) (Metric 2,000 kilo)

INSTALLATION: (See “Installation Drawing - Electronic Single Ton Container”, on Page 5 of the O&M Manual)

These scales consist of two basic assemblies: An electronic load cell with cable connected to a digital readout, and the fabricated steel scale frame complete with trunnions. The Load Cell (with base plate down) is placed on a level concrete floor directly under the rail of a monorail hoist (this type of hoist is generally used to load the ton containers on the scale). The scale frame is now placed over the Load Cell, such that the hole on the lip of the frame is centered over the load button on the Load Cell. If your load button does not align with the hole on the lip of the frame, field calibration of your scale will be necessary. Be sure to position the Load Cell so that it is parallel with the scale frame (See Drawing 29626a-SOLO).

The Load Cell is equipped with 20' of shielded cable which connects to the inside of the bottom of the indicator (see page 10. If you are imbedding conduit in your concrete pad, between your scale and indicator, we recommend 1-1/2" ID conduit so you can fit all your load cell cables in one conduit. DO NOT run any other inductive load with your load cell cable.

CAUTION: DO NOT CUT LOAD CELL CABLE !!!. THIS WILL VOID YOUR WARRANTY. Now the scale frame hinge and Load Cell can be lag bolted (Red Head Anchor Bolts) to the concrete floor, and the digital readout mounted in a convenient location.

QUESTIONS ? Call our HELP HOTLINE 1-800-893-6723

S.1.112 REF: WP\O&M\CHLORSOL\ SOLOSGL..wpd (S01.pdf)

FORCE FLOW

HELP HOTLINE 1-800-893-6723 www.forceflow.com [email protected]

NOTES:

INDEX SOLO 1000 Indicator with CHLOR-SCALE 1- thru 6-TANK

SECTION S.1.000

INSTALLATION OF 1-TANK SCALE PLATFORM: S.1.101 Dimensioned Installation Drawing S.1.102 1-Tank Platform Installation Instructions

YOU ARE HERE !

INSTALLATION OF 2-TANK SCALE PLATFORM: S.1.121 Dimensioned Installation Drawing S.1.122 2-Tank Platform Installation Instructions INSTALLATION OF 3- thru 6- TANK SCALE PLATFORM: S.1.131 3-Tank Dimensioned Installation Drawing S.1.132 4-Tank " (etc) S.1.133 5-Tank " (etc) S.1.134 6-Tank " (etc) S.1.135 Platform Installation Instructions S.1.136 Pad Placement for Multiples INSTALLATION OF LOAD CELL S.1.141 Load Cell Data Sheet S.1.142 Load Cell Assembly Drawing INSTALLATION OF INDICATOR S.1.201-1 1-Channel Indicator Wiring & Plumbing Drawing S.1.201-2 2-Channel " (etc) S.1.202-1 1-Channel Instructions: Power; Load Cell & Tare Adjust; 4-20mA S.1.202-2 2-Channel " (etc) S.1.203-1 1-Channel Instructions: Set Point; Surge & Static Protection S.1.203-2 2-Channel " (etc) INSTALLATION CHECK LISTS S.1.301 Installation Check List S.1.305 Start-Up Check List (Portable or Fixed Tanks)

S.2.000

SCALE OPERATION: S.2.101 Tank Scale Operation OPTIONAL ALARM SET POINT: S.2.301-1 1-Channel Alarm Set Point Configuration S.2.301-2 2-Channel Alarm Set Point Configuration

FORCE FLOW F LO Q U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected] REF: T4\O&M\TONSOLO\Y45.tcw etc (Y45.pdf etc)

MODEL NUMBERS (for Frame & Load Cell) DR80 (8000 lbs) DR40K (4000 kgs) FORCE FLOW EQUIPMENT

FLOQUIP

SOLO

1000

1234.5

MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR-1000-1 2-Channel SR-1000-2

FORCE FLOW

45" (1143mm)

F F L L O O Q Q U U II P P

_________ Model Number of Indicator (Lbs or Kgs ______) _________ Model Number of Frame _________ Feet of Cable per Scale (20' Standard)

61-7/8" (1572mm)

Frame with Welded Round Stock under Tongue (rests on top of other frame)

4" 11-3/8" (289mm)

Frame with Flat Plate (rests on Load Cell)

Load Cell

80" (2032mm)

Load Cell

30" (762mm)

TON CONTAINER

8" (203mm) 44" (1118mm)

S.1.121

FORCE FLOW

IMPORTANT: Position Load Cell so that it is parallel with the scale frames. Read the installation section carefully for proper placement of the frames.

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

FLOQ U I P

File: T4\O&M\TONSOLO\SOLODBL.tcw (S04.pdf) (WEB: TON2SOLO.pdf)

Drawn by:

ELECTRONIC DUAL TANK SCALE CHLOR-SCALE with SOLO 1000 (8000 lb. or 4000 kg. Capacity)

SLP

Date:

09/01/98

Revised:

01/21/97

Scale:

NONE

Drawing Number

30279

INSTALLATION

MODEL DR80 (Metric Model Number DR40K) with SOLO 1000 INDICATOR Two (2) Tank Scale (8,000 lb. Capacity) (Metric 4,000 kilo)

INSTALLATION: (See “Installation Drawing - Electronic Dual Ton Container” on Page 7 of the O&M Manual)

These scales consist of three basic assemblies: An electronic load cell with cable connected to a digital readout, and two fabricated steel scale frames complete with trunnions. The Load Cell (with base plate down) is placed on a level concrete floor directly under the rail of a monorail hoist (this type of hoist is generally used to load the ton containers on the scale). The scale frame with FLAT plate is now placed so the hole in the center of the flat plate rests over the center of the load button on the load cell. The other scale frame with the ROUND STOCK on the plate is then placed so that the round stock rests on the center hole of the flat plate frame. To assure that the total scale is quare, make sure that the distance from frame to frame measured from the outer edges of the scale measure 62" at each end. Also, that there is 11-1/2" clearance between the frames. If these dimensions are correct and the load cell is centered, the scale will weigh correctly. Be sure to position the Load Cell so that it is parallel with the scale frames (See Drawing 29625SOLO). The Load Cell is equipped with 20' of shielded cable which connects to the inside of the bottom of the indicator (see page 10). If you are imbedding conduit in your concrete pad, between your scale and indicator, we recommend 1-1/2" ID conduit so you can fit all your load cell cables in one conduit. DO NOT run any other inductive load with your load cell cable.

CAUTION: DO NOT CUT LOAD CELL CABLE !!!. THIS WILL VOID YOUR WARRANTY. Now the scale frame hinges and Load Cell can be lag bolted (Red Head Anchor Bolts) to the concrete floor, and the digital readout mounted in a convenient location. S.1.122 Questions ?

Our HELP HOTLINE is 1-800-893-6723 REF: WP\O&M\CHLORSOL\SOLODBL.wpd (S03.pdf)

FORCE FLOW

HELP HOTLINE 1-800-893-6723 www.forceflow.com [email protected]

NOTES:

INDEX SOLO 1000 Indicator with CHLOR-SCALE 1- thru 6-TANK

SECTION S.1.000

INSTALLATION OF 1-TANK SCALE PLATFORM: S.1.101 Dimensioned Installation Drawing S.1.102 1-Tank Platform Installation Instructions INSTALLATION OF 2-TANK SCALE PLATFORM: S.1.121 Dimensioned Installation Drawing S.1.122 2-Tank Platform Installation Instructions INSTALLATION OF 3- thru 6- TANK SCALE PLATFORM: S.1.131 3-Tank Dimensioned Installation Drawing S.1.132 " (etc) 4-Tank S.1.133 " (etc) 5-Tank " (etc) S.1.134 6-Tank S.1.135 Platform Installation Instructions S.1.136 Pad Placement for Multiples

YOU ARE HERE !

INSTALLATION OF LOAD CELL S.1.141 Load Cell Data Sheet S.1.142 Load Cell Assembly Drawing INSTALLATION S.1.201-1 S.1.201-2 S.1.202-1 S.1.202-2 S.1.203-1 S.1.203-2

OF INDICATOR 1-Channel Indicator Wiring & Plumbing Drawing 2-Channel " (etc) 1-Channel Instructions: Power; Load Cell & Tare Adjust; 4-20mA 2-Channel " (etc) 1-Channel Instructions: Set Point; Surge & Static Protection 2-Channel " (etc)

INSTALLATION CHECK LISTS S.1.301 Installation Check List S.1.305 Start-Up Check List (Portable or Fixed Tanks)

S.2.000

SCALE OPERATION: S.2.101 Tank Scale Operation OPTIONAL ALARM SET POINT: S.2.301-1 1-Channel Alarm Set Point Configuration S.2.301-2 2-Channel Alarm Set Point Configuration

FORCE FLOW F LO Q U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected] REF: T4\O&M\TONSOLO\Y45.tcw etc

(Y45.pdf etc)

WEIGHT: 730 lbs/331 kgs (palletized for shipment)

FORCE FLOW EQUIPMENT

FLOQUIP

SOLO 1000

NOTE: Use 1/2" x 1-1/2" (13 x 38mm)Anchor Bolts

1234

RECOMMENDATION: 12" (305mm) mimimum pad be used for each foot. DO NOT PREPOUR ANCHOR BOLTS. Use frame as template.

FORCE FLOW FLOQ U I P

MODEL NUMBERS (for Frame & Load Cell) DR120 (12,000 lbs) DR60K (6,000 kgs) MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR000-1 2-Channel SR000-2

Tanks on 34" (864mm) Centers

______ Model Number of Indicator (Lbs. or Kgs. _____) ______ Model Number of Frames

96" (2438mm)

______ Feet of Cable (20'/6M Std)

See ANCHOR PAD LOCATION Drawing for 3- to 6-Tank Scales

33.5" Max (851mm)

12" (305mm) 48" (1219mm)

S.1.131

FORCE FLOW F LOQ U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

Drawn by:

ELECTRONIC 3-TANK SCALE CHLOR-SCALE with SOLO 1000 INDICATOR (12,000 lb. or 6,000 kg. Capacity)

File: T4\O&M\TONELEC\SOLO3TNK.tcw (S13.pdf) (WEB: TON3SOLO.pdf)

Date:

SLP

Drawing Number

09/01/95

Revised:

10/01/00

Scale:

None

30283

NOTE: Use 1/2" x 1-1/2" (13mm x 38mm) Anchor Bolts FORCE FLOW EQUIPMENT

FLOQUIP

SOLO 1000

1234

RECOMMENDATION: 12" (305mm) minimum pad be used for each foot. DO NOT PREPOUR ANCHOR BOLTS. Use frame as template to avoid binding.

FORCE FLOW F LO Q U I P

MODEL NUMBERS (for Frame & Load Cell) DR160 (16,000 lbs) DR80K (8,000 kgs) MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR000-1 2-Channel SR000-2

129" (3277mm)

______ Model Number of Indicator (Lbs. or Kgs _____) ______ Model Number of Frame ______ Feet of Cable (20'/6M Std)

Tanks on 34" (864mm) Centers

See ANCHOR PAD LOCATION Drawing for 3- to 6-Tank Scales

33.5" Max (851mm Max)

12" (305mm)

48" (1219mm)

S.1.132

FORCE FLOW

WEIGHT: 1,050 lbs/476 kgs (palletized for shipment) 1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

F LOQ U I P

File: T4\O&M\TONELEC\SOLO4TANK.tcw (S14.pdf)

Drawn by:

ELECTRONIC 4-TANK SCALE CHLOR-SCALE with SOLO 1000 INDICATOR (16,000 lb. or 8,000 kg. Capacity)

(WEB: TON4SOLO.pdf)

SLP

Date:

09/13/00

Revised:

10/01/00

Scale:

1 in. = 21 in.

Drawing Number

30282

MODEL NUMBERS (for Frame & Load Cell) DR200 (20,000 lbs) DR100K (10,000 kgs)

SOLO 1000

1234 FORCE FLOW F L O Q U I P

MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR000-1 2-Channel SR000-2

Tanks on 34" (864mm) Centers

NOTE: Use 5/8" x 1-1/2" (16mm x 38mm) Anchor Bolts RECOMMENDATION: 12" (305mm) minimum pad be used for each foot. DO NOT PREPOUR ANCHOR BOLTS. Use frame as template to avoid binding. 162" (4115mm)

CL of Tank

______ Model Number of Indicator (Lbs or Kgs ______) ______ Model Number of Scale Frame ______ Feet of Cable (20 feet/6M Std)

CL of Tank

See ANCHOR PAD LOCATION Drawing for 3- to 6-Tank Scales

44" (1118mm)

30" (762mm)

CL of Tank

14" (356mm) 48" (1219mm)

S.1.133

FORCE FLOW F LOQ U I P

WEIGHT: 1890 lbs/857 kgs (palettized for shipment)

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

ELECTRONIC 5-TANK SCALE CHLOR-SCALE with SOLO 1000 INDICATOR (20,000 lb. or 10,000 kg. Capacity)

File: T4\O&M\TONELEC\SOLO5TNK.tcw (S15.pdf) (WEB: TON5SOLO.pdf)

Drawn by:

SLP

Date:

09/01/95

Revised:

12/08/98

Scale:

NONE

Drawing Number

30294

MODEL NUMBERS (for Frame & Load Cell) DR240 (24,000 lbs) DR120K (12,000 kgs)

C

L of Tank

SOLO 1000

1234 FORCE FLOW F LO Q U I P

MODEL NUMBER (for SOLO 1000 Indicator) 1-Channel SR000-1 2-Channel SR000-2

C

L of Tank

NOTE: Use 5/8" x 1-1/2" (16mm x 38mm) Anchor Bolts RECOMMENDATION: 12" (305mm) minimum pad be used for each foot. DO NOT PREPOUR ANCHOR BOLTS. Use frame as template to avoid binding.

Tanks on 34" (864mm) Centers

195" (4953mm)

______ Model Number of Indicator (Lbs or Kgs _____) ______ Model Number of Frame ______ Feet of Cable (20' or 305 mm Std)

C

L of Tank

See ANCHOR PAD LOCATION Drawing for 3- to 6-Tank Scales

30" 44" (762mm) (1118mm)

C

L of Tank 14" (356mm) 48" (1219mm)

48" (1219mm)

S.1.134

WEIGHT: 2160 Lbs (980 kgs) (palletized for shipping)

FORCE FLOW F LOQ U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

ELECTRONIC 6-TANK CHLOR-SCALE FOR TON CONTAINERS with SOLO INDICATOR (24,000 lb. Capacity)

File: T4\O&M\TONELEC\SOLO6TNK.tcw (S16.pdf) (WEB: TON6SOLO.pdf)

Drawn by:

SLP

Date:

09/01/95

Revised:

12/08/98

Scale:

NONE

Drawing Number

30293

INSTALLATION MULTIPLE TANK SCALES DR120 DR160 DR200 DR240

3-Tank Scale (12,000 lb) 4-Tank Scale (16,000 lb) 5-Tank Scale (20,000 lb) 6-Tank Scale (24,000 lb)

(Metric DR60K) (Metric DR80K) (Metric DR100K) (Metric DR120K)

with SOLO 1000 INDICATOR

INSTALLATION: (See “Installation Drawing - Electronic Multiple Tank” on Page 9 of the O&M Manual)

These scales consist of two basic assemblies: An electronic load cell with cable connected to a digital readout, and the fabricated steel scale frame complete with levers and trunnions. The frame assembly is placed on a level concrete floor directly under the rail of a monorail hoist (this type of hoist is generally used to load and unload the ton containers on the scale). The load cell is bolted under the center beam with the bolts provided. NOTE: WHEN ATTACHING LOAD CELL TO CENTER BEAM, BE SURE LOAD BUTTON IS FACING DOWN AND THAT LOAD CELL SHIM IS BETWEEN LOAD CELL AND BASE PLATE.

Note: The shear-beam load cell must be cantilevered to allow deflection when weight is applied from the upper lever arm to the load button. The lever arm must contact the LOAD BUTTON only and no other part of the load cell anchor assembly. (See drawing 29894SOLO on page 9 and Drawing 29818a on page 10). The Load Cell is equipped with 20' of shielded cable which connects to the inside of the bottom of the indicator (see page 14). If you are imbedding conduit in your concrete pad, between your scale and indicator, we recommend 1-1/2" ID conduit so you can fit all your load cell cables in one conduit. DO NOT run any other inductive load with your load cell cable.

CAUTION: DO NOT CUT LOAD CELL CABLE !!!. THIS WILL VOID YOUR WARRANTY. Now the scale frame at the four corner stands can be lag bolted with ½" bolts and washers (Red Head Anchor Bolts) to the concrete floor, and the digital readout mounted in a convenient location. The scale is now ready for weighing. S.1.135 Questions ?

Our HELP HOTLINE is 1-800-893-6723 REF: WP\O&M\CHLORSOL\SOLOMUL.wpd (SO5.pdf)

DO NOT PREPOUR ANCHOR BOLTS

Centerline of Foot

RECOMMEND MOUNTING PADS BE A MINIMUM OF 12" x 12"

Y

Centerline of Foot

Z

All dimensions are CENTERLINE of Foot Use Scale Platform as Template for Bolt Location to avoid binding.

Centerline of Foot

W Scale

W

X

Y

Z

3-Tank 4-Tank 5-Tank 6-Tank

74 1/2" 101 7/8" 129 1/2" 155"

31" 31" 30" 26 1/2"

10 3/4" 13 9/16" 16 1/4" 20"

8 1/2" 8 1/2" 9" 10 3/4"

Centerline of Foot

X

W.1.136 S.1.136 C.1.136

FORCE FLOW FLOQU I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected]

File: T4\O&M\TONHYD\MULTFOOT.tcw (P16.pdf)

PAD PLACEMENT FOR MULTIPLE TANK SCALES

Drawn by:

SLP

Date:

09/01/95

Revised:

01/27/97

Scale:

NONE

Drawing Number

30086

FORCE FLOW

HELP HOTLINE 1-800-893-6723 www.forceflow.com [email protected]

NOTES:

INDEX SOLO 1000 Indicator with CHLOR-SCALE 1- thru 6-TANK

SECTION S.1.000

INSTALLATION OF 1-TANK SCALE PLATFORM: S.1.101 Dimensioned Installation Drawing S.1.102 1-Tank Platform Installation Instructions INSTALLATION OF 2-TANK SCALE PLATFORM: S.1.121 Dimensioned Installation Drawing S.1.122 2-Tank Platform Installation Instructions INSTALLATION OF 3- thru 6- TANK SCALE PLATFORM: S.1.131 3-Tank Dimensioned Installation Drawing S.1.132 4-Tank " (etc) S.1.133 5-Tank " (etc) S.1.134 6-Tank " (etc) S.1.135 Platform Installation Instructions S.1.136 Pad Placement for Multiples

YOU ARE HERE !

INSTALLATION OF LOAD CELL S.1.141 Load Cell Data Sheet S.1.142 Load Cell Assembly Drawing INSTALLATION OF INDICATOR S.1.201-1 1-Channel Indicator Wiring & Plumbing Drawing S.1.201-2 2-Channel " (etc) S.1.202-1 1-Channel Instructions: Power; Load Cell & Tare Adjust; 4-20mA S.1.202-2 2-Channel " (etc) S.1.203-1 1-Channel Instructions: Set Point; Surge & Static Protection S.1.203-2 2-Channel " (etc) INSTALLATION CHECK LISTS S.1.301 Installation Check List S.1.305 Start-Up Check List (Portable or Fixed Tanks)

S.2.000

SCALE OPERATION: S.2.101 Tank Scale Operation OPTIONAL ALARM SET POINT: S.2.301-1 1-Channel Alarm Set Point Configuration S.2.301-2 2-Channel Alarm Set Point Configuration

FORCE FLOW F LO Q U I P

1150-D Burnett Ave, Concord, CA 94520 USA 1-800-893-6723 US & Canada, Fax: 925-686-6713 www.forceflow.com / [email protected] REF: T4\O&M\TONSOLO\Y45.tcw etc (Y45.pdf etc)

RATED CAPACITY (lbs) --

.5K, 1K, 1.5K, 2.5K, 4K, 5K and 10K

FULL SCALE OUTPUT (mV/V) --

3.0 +/- 0.25%

B

WIRING

E

BRIDGE RESISTANCE -343 - 357 349 - 355

Input (ohms) Output (ohms)

Input Input Output Output Shield

RED BLACK GREEN WHITE BARE

SEALING --

Environmentally Protected for NEMA 6 or IP67

MATERIAL/FINISH --

Alloy Tool Steel Electroless Nickel

CABLE --

4-Conductor, 22 AWG, Shielded and Jacketed, 20 ft. standard

D C H

CL G typ 2 places

F

LOAD CELL BASE PLATE

11/16" Hole (typ 2 places)

Capacity (lbs)

A1

A2

B

C

D

E

F

G

500

1.00

1.25

5.12

.62

1.00

3.00

2.25

.53

1/2-20 UNF-2B, 0.53 x .50 DP. C'BORE

1K - 4K

1.25

1.25

5.12

.62

1.00

3.00

2.25

.53

1/2-20 UNF-2B, 0.53 X .62 DP. C'BORE

.78

3/4-16 UNF-2B, 0.78 X .75 DP. C'BORE

5K - 10K

1.50

1.50

6.75

.75

1.50

3.75

ACCURACY CLASS

Standard (Class 3)