Solar Inverters Product Catalogue UK. Solar inverters, monitoring and support for installations from 2.5 kw to more than 1 MW

Solar Inverters Product Catalogue UK Solar inverters, monitoring and support for installations from 2.5 kW to more than 1 MW Content About us 2 ...
Author: Audrey Elliott
3 downloads 1 Views 2MB Size
Solar Inverters Product Catalogue UK Solar inverters, monitoring and support for installations from 2.5 kW to more than 1 MW

Content

About us

2

SOLIVIA - Solar inverters

4

Installations of up to 10 kWP

6

Installations of 10 kWP to 100 kWP

8

Installations from 100 kWP

10

SOLIVIA Monitor

12

Delta Service & Support

14

SOLIVIA Solar seminars

16

SOLIVIA Accessories

18

1

About us

At Delta Energy Systems, we believe that much more than just good products are needed to maximise your energy efficiency. The key to our continued success is how well we understand the demands and needs of our customers – day after day, year after year. We have been partners with some of the largest hightech companies in the world for more than 40 years. Our power solutions have contributed to the success of much of our partners‘ ground breaking technology and have helped them to stay ahead in a rapidly changing world. Together with our customers, we offer innovative nextgeneration solutions for the efficient use of solar energy that already work and upgrade your solar system now for the future.

The Delta Group is an international high-tech company with more than 80,000 employees worldwide and a turnover of 7 billion USD. Since 1999, Delta Energy Systems (Germany) – a subsidiary of the Delta Group – has invested in research and development in the solar inverter program in Germany.

When it comes to energy, we believe partnership is the real power.

2

Photovoltaic installation at Delta in Teningen (Germany): 46 kW output power – 205 solar modules – 15 string inverters. 3

SOLIVIA - Solar inverters

Delta offers a complete product range of solar inverters, accessories and services to our partners and installers and the best photovoltaic systems to maximise profit. SOLIVIA stands for „SOLar inverters for Versatile and Intelligent Applications“ “Solar Wechselrichter für vielfältige und intelligente Anwendung”). SOLIVIA solar inverters are multifaceted and can be used in every system size as well as are compatible with all commercially available solar modules and system components.

SOLIVIA solar inverters are not only the heart of your system, but also the intelligent control equipment of your power generation in conjunction with the Delta monitoring system. Delta solar inverters come with a standard warranty of 10 years, which can of course be extended to 20 years. Our Solar Team is always available to support you. We would be happy to assist you in the planning of your installations.

Installation sizes Installations of up to 10 kWP (for example single or multi-family homes): SOLIVIA 2.5 TR

SOLIVIA 3.0 TR



SOLIVIA 3.3 TR



SOLIVIA 5.0 TR

Installations of 10 kWP to 100 kWP (for example industrial buildings):

SOLIVIA 11 TR



SOLIVIA 15 TL



SOLIVIA 20 TL

Installations from 100 kWP (for example large-scale installations): SOLIVIA 20 TL

4

Versatile applications

Maximum profitability

SOLIVIA string inverters can be used with all commercially available photovoltaic modules. Even solar panels that require the solar generator to be grounded at the positive or negative pole can be easily used with SOLIVIA inverters. The wide input voltage range of SOLIVIA inverters offers maximum flexibility for system installation.

SOLIVIA solar inverters achieve a peak efficiency of up to 98.0 % and offer one of the largest operating temperature ranges available. Full output up to 55 °C ambient temperature to maximise energy efficiency and ensure maximum profitability.

Aluminium housing

Maximum flexibility

The aluminium housing of the SOLIVIA solar inverters ensure long lasting protection against moisture and corrosion. The dust-proof, completely shockproof housing protects the electronics of the solar inverter from water spray from all directions. This means that it can be installed in protected outdoor areas, damp basements and areas with a high level of dust (agriculture).

The international software integrated in each inverter reduces our distribution partners’ logistics and storage costs. With the SOLIVIA Europe series, only one unit type needs to be stored for each perfor-mance category. This is then configured on site in the country of use.

Easy installation The required power supply for the DC disconnector is already installed in the SOLIVIA inverter. As a result, no external, expensive DC disconnector is needed. The lightweight, compact design combined with the unique wall bracket makes installation of the solar inverter a piece of cake.

5

Installations of up to 10 kWP

SOLIVIA solar inverters 2.5 kW to 5.0 kW SOLIVIA PRODUCT RANGE

SOLIVIA 2.5 TR

SOLIVIA 3.0 TR

SOLIVIA solar inverters from Delta are the perfect choice if you want a solar system for a single or multi-family house. SOLIVIA inverters are the ideal solution for private homeowners. The inverters are fanless and therefore fairly quiet. The quality aluminium housing will look like new for years to come. The private home-owner can check his installation on the Internet at any time with the free* monitoring solution from Delta. All status messages can be directly read on the easy-to-use inverter display.

SOLIVIA 3.3 TR

For an installation of up to 10 kWP, we recommend the following SOLIVIA inverters: SOLIVIA 2.5 TR SOLIVIA 3.0 TR SOLIVIA 3.3 TR SOLIVIA 5.0 TR Our Delta Service & Support Team will be happy to advise the installer and the end customer should any questions arise about the use of the SOLIVIA inverter.

The installer can also get extensive inverter data on his PC and configure the settings easily with the free service software.

* 5 years free. After this period you can renew for a further 5 years for only EUR 40.00. 6

SOLIVIA 5.0 TR

Technical data SOLIVIA 2.5 to SOLIVIA 5.0 INPUT (DC)

SOLIVIA 2.5 TR

SOLIVIA 3.0 TR

SOLIVIA 3.3 TR

Max. recommended PV power

3100 WP

3700 WP

4000 WP

SOLIVIA 5.0 TR 6000 WP (5320 WP DE / 5250 WP BE)

Nominal power

2750 W

3333 W

3630 W

5500 W (4850 W DE / BE)

Voltage range

125 ... 540 V

125 ... 600 V

Full power MPP range

150 ... 450 V

150 ... 480 V

Nominal current

10.0 A

12.0 A

13.3 A

15.7 A @ 350 A

Max. current

18.0 A

21.7 A

24.0 A

36.6 A

Max. (apparent) power

2600 W 1)

3130 W 1)

3485 W 1)

5500 VA (5060 VA DE / 5000 VA BE) 1)

Nominal (apparent) power

2500 W

3000 W

3300 W

5000 VA (4600 VA DE / BE)

OUTPUT (AC)

Voltage range

184 ... 264 V 2)

Nominal current

11.0 A

13.0 A

14.4 A

22.0 A

Max. current

13.0 A

16.0 A

17.0 A

34.0 A

Nominal frequency

50 Hz

Frequency range

47.0 ... 52.0 Hz 2)

45.0 ... 65.0 Hz 2)

Power factor (cos φ)

> 0.99 @ nominal power

> 0.99 @ nominal apparent power 3)

Total harmonic distortion (THD)

< 3 % @ nominal power

< 5 % @ nominal apparent power

MECHANICAL DESIGN Size (L x W x D)

410 x 410 x 180 mm

Weight

512 x 410 x 182 mm

21.5 kg

25.0 kg

Cooling

Convection

AC connector

Wieland RST25i3S

DC connector

3 pairs of Tyco Solarlok

Communication interfaces

3 pairs of Multi-Contact MC4

2 x RJ45 / RS485

DC disconnector

2 x RJ45 / RS485 + 1 x USB Integrated

Display

3 LEDs, 2-line LCD

3 LEDs, 4-line LCD

GENERAL SPECIFICATION Model name

SOLIVIA 2.5 EU G3

SOLIVIA 3.0 EU G3

Part number Delta

EOE45010268

EOE46010266

Max. efficiency Efficiency EU

SOLIVIA 3.3 EU G3

SOLIVIA 5.0 EU G4 TR

EOE46010190

EOE46010253

96.0 % 94.4 %

94.7 %

94.8 %

Operating temperature

-25 ... +70 °C

Full power without derating

-25 ... +55 °C

Storage temperature Humidity Max. operating altitude

-25 ... +80 °C 0 ... 98 %

0 ... 95 % 2000 m (above sea level)

STANDARDS / DIRECTIVES Protection degree Safety class Configurable trip parameters Insulation monitoring Overload behavior Anti-islanding protection / Grid regulation EMC Safety

IP65 I Yes Yes Current limitation; power limitation DIN VDE 0126-1-1; RD 1663; RD 661; ENEL G.L. 2010; UTE 15712-1; Synergrid C10/11; EN 50438; G83/1-1; VDE AR N 4105 (LVD) EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3 EN60950-1; EN50178; IEC62103; IEC62109-1 / -2

DIN VDE 0126-1-1; RD 1663; RD 661; ENEL G.L. 2010; UTE 15712-1; Synergrid C10/11; EN 50438; G59/2; VDE AR N 4105 (LVD) EN61000-6-2; EN61000-6-3; EN61000-3-11; EN61000-3-12 IEC62103; IEC62109-1 / -2

1) The maximum (apparent) AC power value indicates the power an inverter might be able to deliver. However, such a maximum (apparent) AC power may not necessarily be achieved. 2) AC voltage and frequency range will be programmed according to the individual country requirements. 3) Cos Phi = 0,8 cap ... 0,8 ind

7

Installations of 10 kWP to 100 kWP

SOLIVIA solar inverters 11 kW to 20 kW SOLIVIA PRODUCT RANGE

SOLIVIA 11 TR

SOLIVIA 15 TL

For medium sized systems, such as those frequently used in the commercial or agricultural sectors, our 3-phase SOLIVIA solar inverters are ideal: SOLIVIA 11 TR SOLIVIA 15 TL SOLIVIA 20 TL The three-phase SOLIVIA inverters have maximum efficiency of up to 98.0%. In comparison with commercially available devices, the Delta inverters offer the highest efficiency with a much wider power range. Combined with very good temperature performance (no power loss up to 55 °C) they ensure maximum yield and profits, even with outdoors installations. The integrated USB interface of the SOLIVIA 11 TR is used for updating the firmware, uploading and downloading settings as well as for recording measurement data.

8

SOLIVIA 20 TL

The comparatively low weight and compact design facilitates handling significantly. The supplied mounting plate simplifies the installation of SOLIVIA solar inverters. After mounting the plate to the desired location, the inverter is simply pushed onto the wall mount on the rails – no further drilling is required. The environmental conditions in agriculture and industry place high demands on an inverter. The completely sealed and shockproof housing protects the solar inverter from dust and water spray from all directions, so that SOLIVIA inverters can be installed in these areas and in protected outdoor areas.

Technical data SOLIVIA 11 to SOLIVIA 20 INPUT (DC)

SOLIVIA 11 TR

SOLIVIA 15 TL

SOLIVIA 20 TL

Max. recommended PV power

13.3 kWP

19.0 kWP

25.0 kWP

15.3 kW

Nominal power

11.6 kW

Voltage range

400 ... 900 V 1)

200 ... 1000 V

20.4 kW

Full power MPP range

425 ... 800 V

350 ... 800 V

Nominal current

19.5 A @ 600 V

12 A @ 640 V (per MPP)

16 A @ 640 V (per MPP)

Max. current

29.0 A

48 A (24 A per MPP)

60 A (30 A per MPP)

15.75 kVA 2)

21.0 kVA 2)

OUTPUT (AC) Max. apparent power

11 kVA

Nominal apparent power

11 kVA

Voltage range (3 phases, 5 wires)

3 x 400 V + N + PE (+18/-20%) 3)

2)

15.0 kVA

20.0 kVA 3 x 230 / 400 V + N + PE 3)

Nominal current (per phase)

16.0 A

22 A

29 A

Max. current

20.0 A

25 A

32 A

Nominal frequency

50 Hz

Frequency range

50 Hz ± 5 Hz 3)

Power factor (cos φ)

> 0.99 @ nominal apparent power 4)

Total harmonic distortion (THD)

< 5 % @ nominal apparent power

Night consumption

< 1.0 W

50 / 60 Hz 50 Hz: 45.0 ... 55.0 Hz; 60 Hz: 55.0 ... 65.0 Hz 3) > 0.99 @ nominal apparent power 4) < 3 % @ nominal apparent power < 2.0 W

MECHANICAL DESIGN Size (L x W x D)

685 x 410 x 185 mm

Weight

39.0 kg

952 x 625 x 275 mm

Cooling

Fan (plug & play)

Fan

AC connector

Amphenol C16/3

Amphenol C16/3

67.2 kg

DC connector

3 pairs of Multi-Contact MC4

4 pairs of Multi-Contact MC4

Communication interfaces

2 x RJ45 / RS485 + 1 x USB

2 RJ45 / RS485

DC disconnector

Integrated

Display

3 LEDs, 4-line LCD

Integrated Black/white graphical LCD

GENERAL SPECIFICATION Model name

SOLIVIA 11 EU G4 TR

SOLIVIA 15 EU G4 TL EOE48010362

SOLIVIA 20 EU G4 TL

Part number Delta

EOE48030329

Max. efficiency

96.5 %

EOE48010364

Efficiency EU

96.0 %

Operating temperature

-25 ... +70 °C

-20 ... +60 °C

Full power without derating

-25 ... + 55 °C

-20 ... + 40 °C

Storage temperature

-25 ... +80 °C

-20 ... +70 °C

Humidity

0 ... 95 %

Max. operating altitude

2000 m (above sea level)

98.0 % > 97.8 %

0 ... 90 % 2000 m (above sea level)

STANDARDS / DIRECTIVES Protection degree

IP65 / IP54 5)

Safety class

I

Configurable trip parameters

Yes

Insulation monitoring

Yes

Overload behavior

Current limitation; power limitation

Anti-islanding protection / Grid regulation

DIN VDE 0126-1-1; RD 1663; RD 661; ENEL G.L. 2010; UTE 15712-1; Synergrid C10/11; EN 50438; G83/1-1; VDE AR N 4105 (LVD); BDEW (MVD)

EMC

EN61000-6-2; EN61000-6-3; EN61000-3-11; EN61000-3-12

Safety

IEC62103; IEC62109-1 / -2

1) Maximum input voltage without damage: 1000 V 2) The maximum (apparent) AC power value indicates the power an inverter might be able to deliver. However, such a maximum (apparent) AC power may not necessarily be achieved. 3) AC voltage and frequency range will be programmed according to the individual country requirements.

IP65 / IP55 6) I Yes Yes Current limitation; power limitation DIN VDE 0126-1-1; RD 1663; RD 661; ENEL G.L. 2010; G59/2; UTE 15712-1; Synergrid C10/11; EN 50438; G59/2; VDE AR N 4105 (LVD); BDEW (MVD); AS 4777 EN61000-6-2; EN61000-6-3; EN61000-3-11; EN61000-3-12, C-Tick IEC62109-1 / -2, AS/NZS 3100 4) Cos Phi = 0,8 cap ... 0,8 ind 5) IP65 for electronics / IP54 for cooling area 6) IP65 for electronics / IP55 for cooling area

9

Installations from 100 kWP

SOLIVIA solar inverters 20 kW SOLIVIA PRODUCT RANGE

SOLIVIA 20 TL

Large installations such as solar farms, which are mostly run by operating companies, have outputs of 100 kWP upwards. The use of string inverters with large installations such as these provides many advantages. The modular structure of such systems ensures the highest flexibility, as this can easily be extended without a lot of work at any time. You can also save valuable time and money, because maintenance is much lower than in solutions with central inverters. Thanks to the use of several individual string inverters, your solar installation continues to supply power into the grid and your yield continues to increase even at failure of one inverter. DC cable losses caused by such decentralised topology are minimized. Delta transformerless SOLIVIA 20 TL solar inverters are perfect for operating large systems.

10

The 3-phase SOLIVIA 20 TL is very compact for its power and is highly efficient. A wide input voltage range of 200 V to 1000 V and 2 MPP trackers provide you with maximum system configuration flexibility. The solar inverters have an integrated DC disconnector, which saves you installation costs and the expense of an external DC disconnector. The transformerless inverters are compatible with monitor solutions from Meteocontrol and Solare Datensysteme. You can check the status of your solar installation and yield at any time from anywhere.

Technical data SOLIVIA 20 INPUT (DC)

SOLIVIA 20 TL

Max. recommended PV power

25.0 kWP

Nominal power

20.4 kW

Voltage range

200 ... 1000 V

Full power MPP range

350 ... 800 V

Nominal current

16 A @ 640 (per MPP)

Max. current

60 A (30 A per MPP)

OUTPUT (AC) Max. apparent power

21.0 kVA 1)

Nominal apparent power

20.0 kVA

Voltage range (3 phases, 5 wires)

3 x 230 / 400 V + N + PE 2)

Nominal current (per phase)

29 A

Max. current

32 A

Nominal frequency

50 / 60 Hz

Frequency range

50 Hz: 45.0 ... 55.0 Hz: 60 Hz: 55.0 ... 65.0 Hz 2)

Power factor (cos φ)

> 0.99 @ nominal apparent power 3)

Total harmonic distortion (THD)

< 3 % @ nominal apparent power

Night consumption

< 2.0 W

MECHANICAL DESIGN Size (L x W x D)

952 x 625 x 275 mm

Weight

67.2 kg

Cooling

Fan

AC connector

Amphenol C16/3

DC connector

4 pairs of Multi-Contact MC4

Communication interfaces

2 RJ45 / RS485

DC disconnector

Integrated

Display

Black/white graphical LCD

GENERAL SPECIFICATION Model name

SOLIVIA 20 EU G4 TL

Part number Delta

EOE48010364

Max. efficiency

98.0 %

Efficiency EU

> 97.8 %

Operating temperature

-20 ... +60 °C

Full power without derating

-20 ... +40 °C

Storage temperature

-20 ... +70 °C

Humidity

0 ... 90 %

Max. operating altitude

2000 m (above sea level)

STANDARDS / DIRECTIVES Protection degree

IP65 / IP55 4)

Safety class

I

Configurable trip parameters

Yes

Insulation monitoring

Yes

Overload behavior

Current limitation; power limitation

Anti-islanding protection / Grid regulation

DIN VDE 0126-1-1; RD 1663; RD 661; ENEL G.L. 2010; G59/2; UTE 15712-1; Synergrid C10/11; EN 50438; G59/2; VDE AR N 4105 (LVD); BDEW (MVD); AS 4777

EMC

EN61000-6-2; EN61000-6-3; EN61000-3-11; EN61000-3-12, C-Tick

Safety

IEC62109-1 / -2, AS/NZS 3100

1) The maximum apparent AC power value indicates the power an inverter might be able to deliver. However, such a maximum apparent AC power may not necessarily be achieved. 2) AC voltage and frequency range will be programmed according to the individual country requirements. 3) Cos Phi = 0,8 cap ... 0,8 ind 4) IP65 for electronics / IP55 for cooling area

11

SOLIVIA Monitor

SOLIVIA Monitor is a turn-key monitoring system suitable for monitoring several PV systems, which ensures reliable operation and a maximum return on your investment in your solar system. With its user-friendly Internet application, which provides a quick overview of the most important values, the yield and the system status, the SOLIVIA Monitor is ideal for monitoring PV systems of up to 30 kW. Easy to understand charts and reports can be displayed at the press of a button. In addition, the system can also show photos of the customer‘s system, local weather information and environmental savings. SOLIVIA Monitor enables installers to monitor their customers‘ installations.

Simple and secure data reporting

reports.

Real-time performance data is gathered from the inverters, sent over the internet, and presented on your computer or webenabled device with easy to read graphs and

System alerts Downtime is minimized with automated alerts providing immediate notification of current or potential problems, which increases the return from your solar investment.

12

Turn-key monitoring system The SOLIVIA Monitor system includes the gateway, database, and web application to allow a complete monitoring solution of one or many solar PV systems.

Technical data SOLIVIA Monitor Monitoring

LANGUAGES

Available languages

English, French, Spanish, Italian, German, Czech, Portugese, Slovak, Dutch, Simplified Chinese, Traditional Chinese, Korean, Thai

PV SYSTEM INFORMATION

Inverter monitoring and communication monitoring

Continuous monitoring between the SOLIVIA inverter and SOLIVIA GW gateway, alert email when connection is disrupted.

GraphS

PV system status

Properties and parameters of your PV system are shown.

Year-by-year comparison

Quick yield overview for the lifetime of the PV system.

Event summary

View event messages in chronological order.

Standard graphs

Standard reports for performance, yield, and DC V- DC A for each inverter or multiple inverters in the PV system.

Data download

Download to a CSV file or copy to the clipboard.

Cloud hosted database

Web-enabled device (Coming soon) SOLIVIA monitor portal displayed on a desktop or Laptop Computer

Router SOLIVIA GW gateway

Solar modules on rooftop

SOLIVIA solar inverter(s)

13

Delta Service & Support

Good service is very important. Therefore Delta provides reliable, flexible and competent support. Customer satisfaction and fast response times are for Delta not just words. Delta cares for partners and customers during the complete lifetime of the product. Our highly motivated Solar Team supports Delta’s customers due to an especially installed Solar Support Hotline which is there when you need help.

14

If necessary, you can receive local support from our service teams. Exchange units and components are available within two working days. Do you need detailed information about the solar inverter; No problem! Our Delta Solar Team offers inverter training courses which can be run either on our premises or on your premises on request.

Service on-site 15

SOLIVIA Solar seminars

16

Expert knowledge around the photovoltaic system is getting more important. Not only in-depth knowledge in relation to the components used but also knowledge of the complete installation should be considered. For this reason, we invite you to participate in one or even several of our interesting and varied photovoltaic seminars. Our multi-faceted seminars are offered at our company locations in Teningen and Soest:



PV Basic Seminar



PV Professional Seminar



PV System Monitoring and Analysis



PV Customized Seminar

All of our seminars are free of charge, and upon request these can be held at your premises or at a location selected by you.

You can obtain further information about our PV seminars on our Internet site: www.training.solar-inverter.com.

If you have any questions, do not hesitate to contact us by e-mail: [email protected] or by phone: 07641 - 455-571.

17

SOLIVIA Accessories

Solar configurator - Delta PART NUMBER DELTA

SOLAR CONFIGURATOR Tool for planning of solar systems. Download: www.solar-inverter.com

Service Software Kit - Delta

The service software is offered within a kit, consisting out of a Delta RS485 cable and a USB to RS485 converter. The software which is necessary to use the kit can be downloaded from our website free of charge. The software enables the installer e.g. to adapt settings, realize firmware upgrades and other updates without any need to open the inverter. The memory from every inverter can be stored and readout with the software in order to facilitate maintenance and on-site service. PART NUMBER SERVICE SOFTWARE KIT DELTA EOE90000220

Kit for all SOLIVIA string inverters. Download: download.solar-inverter.com

Grounding kit - Delta SOLIVIA string inverters can be used with all commercially available photovoltaic modules. Even solar panels that require the solar generator to be grounded at the positive or negative pole can be easily used with SOLIVIA inverters. With the optional grounding kit from Delta, the SOLIVIA inverters are a perfect fit for these applications. PART NUMBER GROUNDING KIT DELTA

18

EOE99000115

Kit for grounding Delta’s SOLIVIA string inverters SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

EOE99000275

Kit for grounding Delta’s SOLIVIA string inverters SOLIVIA 5.0 TR and SOLIVIA 11 TR.

Monitoring systems - Meteocontrol

All SOLIVIA solar inverters are compatible with monitoring systems from Meteocontrol and Solare Datensysteme that allow you to monitor and to record all the different measurement values within a day, week, month or year. DELTA TEILENUMMER

DATENLOGGER

5040007800

WEB’log light + Analog (max. 5 solar inverters; 20 kWP).

5040007900

WEB’log light + DSL / Ethernet (max. 5 solar inverters; 20 kWP).

5040007500

WEB’log Basic Analog, incl. power supply.

5040007700

WEB’log Basic ISDN, incl. power supply.

5040007600

WEB’log Basic DSL / Ethernet, incl. power supply.

5040007100

WEB’log Pro Analog, incl. display & power supply.

5040007200

WEB’log Pro ISDN, incl. display & power supply.

5040007300

WEB’log Pro GPRS, incl. display & power supply.

5040007400

WEB’log Pro DSL / Ethernet, incl. display & power supply.

3081126400

Connect Delta (Easyconnect cable) IP20.

PART NUMBER IRRADIANCE SENSORS DELTA 5040009400

Irradiance sensor Si-12TC, 0 - 10 V.

5040002200

Irradiance sensor Si-12TC-T, 0 - 10 V; incl. temperature

5040009200

Irradiance sensor Si-12TC, 0 - 10 V; incl. 30 meter connection cable.

5040009300

Irradiance sensor Si-12TC-T, 0 - 10 V; incl. temperature and 30 meter connection cable.

5040010600

Irradiance sensor Si-12TC, 0 - 10 V; incl. 15 meter connection cable.

5040010700

Irradiance sensor Si-12TC-T, 0 - 10 V; incl. temperature and 15 meter connection cable.

Monitoring systems - Solare Datensysteme PART NUMBER MONITORING SYSTEMS DELTA Obtainable from Solare Datensysteme: www.solar-log.com.

19

SOLIVIA Accessories

Connection cables - Harting PART NUMBER CONNECTION CABLE DELTA

3081129500

Connection cable from Delta solar inverter to WEB’Logger from Meteocontrol: - Assembled outdoor cable with Harting RJ45 PushPull and RJ12 plugs, IP65, length of 5 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

3081186300

Connection cable from inverter to inverter: - Harting PushPull system cable RJ45, 8-core for IP65/67 applications, length of 1.5 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

3081186500

Connection cable from inverter to inverter: - Harting PushPull system cable RJ45, 8-core for IP65/67 applications, length of 3.0 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

3081186600

Connection cable from inverter to inverter: - Harting PushPull system cable RJ45, 8-core for IP65/67 applications, length of 5.0 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

3081186200

Connection cable from inverter to inverter: - Harting PushPull system cable RJ45, 8-core for IP65/67 applications, length of 10.0 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

3081186400

Connection cable from inverter to inverter: - Harting push-pull system cable RJ45, 8-core for IP65/67 applications, length of 20.0 meters - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR and SOLIVIA 11 TR.

PV plug connectors - Tyco Solarlok PART NUMBER PV PLUG CONNECTORS DELTA

20

3072352725

Tyco Solarlok PV connectors, Female cable coupler Plus coded, 2.5 mm² (AWG 14), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

3072352625

Tyco Solarlok PV connectors, Female cable coupler Minus coded, 2.5 mm² (AWG 14), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

3072350725

Tyco Solarlok PV connectors, Female cable coupler Plus coded, 4.0 mm² (AWG 12), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

3072350625

Tyco Solarlok PV connectors, Female cable coupler Minus coded, 4.0 mm² (AWG 12), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

3072350525

Tyco Solarlok PV connectors, Female cable coupler Plus coded, 6.0 mm² (AWG 10), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

3072350425

Tyco Solarlok PV connectors, Female cable coupler Minus coded, 6.0 mm² (AWG 10), suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

5100221900

Tyco crimping handtool for Solarlok 2.5 mm², suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

5100221800

Tyco crimping handtool for Solarlok 4.0 mm² and 6.0 mm², suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR and SOLIVIA 3.3 TR.

PV plug connectors - Multi-Contact MC4 PART NUMBER PLUG CONNECTORS DELTA Female cable coupler as individual part (including insulating part) Type: PV-KBT4/2,5I-UR; Ø range of cable gland: 3 – 6 mm - Conductor cross section:1.5 - 2.5 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Male cable coupler as individual part (including insulating part) Type: PV-KST4/2,5I-UR; Ø range of cable gland: 3 – 6 mm - Conductor cross section: 1.5 - 2.5 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Female cable coupler as individual part (including insulating part) Type: PV-KBT4/2,5II-UR; Ø range of cable gland: 5.5 – 9 mm - Conductor cross section: 1.5 - 2.5 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Male cable coupler as individual part (including insulating part) Type: PV-KST4/2,5II-UR; Ø range of cable gland: 5.5 – 9 mm - Conductor cross section: 1.5 - 2.5 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Female cable coupler as individual part (including insulating part) Type: PV-KBT4/6I-UR; Ø range of cable gland: 3 – 6 mm - Conductor cross section: 4 - 6 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Male cable coupler as individual part (including insulating part) Type: PV-KST4/6I-UR; Ø range of cable gland: 3 – 6 mm - Conductor cross section: 4 - 6 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Female cable coupler as individual part (including insulating part) Type: PV-KBT4/6II-UR; Ø range of cable gland: 5.5 – 9 mm - Conductor cross section: 4 - 6 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL. Male cable coupler as individual part (including insulating part) Type: PV-KST4/6II-UR; Ø range of cable gland: 5.5 – 9 mm - Conductor cross section: 4 - 6 mm² - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL.

UTE Kit - Tyco Electronics

The UTE Kit Tyco Electronics is a kit based on the French standard UTE C 15-712-1. It contains 8 DC locking devices and an extra signal label. With this kit, you comply with the requirements defined in UTE C 15-712-1 for DC protection and signals. The components included are adapted to the SOLIVIA product family with Tyco SOLARLOK DC connections. PART NUMBER UTE KIT DELTA EOE90000341

UTE kit Tyco Electronics for SOLIVIA solar inverters.

21

SOLIVIA Accessories

UTE kit - Multi-Contact The UTE kit Multi-Contact is a kit that is dedicated for French latest standard: UTE C 15-712-1. This contains 8 DC locking devices, an assembly tool and an additional signalling sticker. That kit will allow you to fulfil DC protection and signalling requirements specified into UTE C 15-712-1 regulation. Included components are adapted for SOLIVIA product line family equipped with MultiContact MC4 DC connectors. PART NUMBER DELTA

UTE KIT

EOE90000341

UTE kit Multi-Contact SOLIVIA solar inverters.

AC Connectors PART NUMBER AC CONNECTORS DELTA 307229555N

AC connector Wieland RST25i3S suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR and SOLIVIA 5.0 TR.

3072390220

AC connector Amphenol C16/3 suitable for SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL.

Terminating plug

22

PART NUMBER DELTA

TERMINATING PLUG

3072438991

- RJ 45 terminating plug G3RT / Harting IP67 - Only suitable for SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVIA 3.3 TR, SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL.

3072438891

- RJ 45 terminating plug G4RT / Harting IP67 - Only suitable for SOLIVIA 5.0 TR, SOLIVIA 11 TR, SOLIVIA 15 TL and SOLIVIA 20 TL.

Photovoltaic installation in Bivona (Italy): 425 kW output power - 81 string inverters. 23

Notes

24

EUROPE Delta Energy Systems (Germany) GmbH

Sales Email: [email protected] Support Email: [email protected]

Delta Renewable Energy Systems (Switzerland) AG

Sales Email: [email protected] Support Email: [email protected]

Delta Energy Systems (Italy) Srl

Sales Email: [email protected] Support Email: [email protected]

Delta Energy Systems (France) SA

Sales Email: [email protected] Support Email: [email protected]

Delta Energy Systems (Spain) S.L.

Sales Email: [email protected] Support Email: [email protected]

Delta Electronics (Slovakia) s.r.o.

Sales Email: [email protected] Support Email: [email protected]

www.solar-inverter.com 13 March 2012 - All information and specifications are subject to change without notice

Sales Email: [email protected] Support Email: [email protected]

Suggest Documents