/ Battery Charging Systems / Welding Technology / Solar Electronics
RECERBO PC Board - Fronius Galvo
42,0410,1941
001-06022013
DE
Einbauanleitung Netzgekoppelter Wechselrichter Installation instructions EN
Print RECERBO - Fronius Galvo
Grid-connected inverter
0
DE
Inhaltsverzeichnis Allgemeines ............................................................................................................................................... Sicherheit .............................................................................................................................................. ESD-Bestimmungen ............................................................................................................................. Lieferumfang ......................................................................................................................................... Erforderliche Werkzeuge und Hilfsmittel............................................................................................... Print RECERBO wechseln ......................................................................................................................... Wechselrichter öffnen ........................................................................................................................... Print ausbauen...................................................................................................................................... Speicher-Print aufstecken..................................................................................................................... Print einbauen....................................................................................................................................... Wechselrichter schließen......................................................................................................................
3 3 3 4 4 5 5 6 7 8 9
1
2
DE
Allgemeines Sicherheit
WARNUNG! Ein elektrischer Schlag kann tödlich sein. Gefahr durch Netzspannung und DC-Spannung von den Solarmodulen. Der DC Hauptschalter dient ausschließlich zum stromlos Schalten des Leistungsteils. Bei ausgeschaltetem DC Hauptschalter steht der Anschlussbereich nach wie vor unter Spannung. Sämtliche Wartungs- und Service-Tätigkeiten dürfen nur dann durchgeführt werden, wenn Leistungsteil und Anschlussbereich voneinander getrennt sind. Der separate Bereich des Leistungsteils darf nur im spannungsfreien Zustand vom Anschlussbereich getrennt werden. Wartungs- und Service-Tätigkeiten im Leistungsteil des Wechselrichters dürfen nur von Fronius-geschultem Servicepersonal durchgeführt werden. WARNUNG! Ein elektrischer Schlag kann tödlich sein. Gefahr durch Restspannung von Kondensatoren. Entladezeit der Kondensatoren abwarten. Die Entladezeit beträgt 3 Minuten. VORSICHT! Unzureichende Schutzleiter-Verbindung kann schwerwiegende Personen- und Sachschäden verursachen. Die Gehäuse-Schrauben stellen eine geeignete Schutzleiter-Verbindung für die Erdung des Gehäuses dar und dürfen keinesfalls durch andere Schrauben ohne zuverlässige Schutzleiter-Verbindung ersetzt werden. VORSICHT! Beschädigungsgefahr des Wechselrichters durch Verschmutzung oder Wasser an den Anschlussklemmen und Kontakten des Anschlussbereiches. Beim Entfernen des Leistungsteils darauf achten, dass Anschlussklemmen und Kontakte am Anschlussbereich nicht verschmutzt oder nass werden. Wandhalterung vor Verschmutzung und Feuchtigkeit schützen.
ESD-Bestimmungen
HINWEIS! Beachten Sie beim Umgang mit elektronischen Bauteilen und Prints die ESD-Bestimmungen. Dazu gehören vor allem ESD-gerechte Verpackungen Arbeitsflächen Böden Sitzgelegenheiten Erdungsmöglichkeiten Handhabung Für einen unsachgemäß behandelten elektronischen Bauteil oder Print können keine Garantie- und Gewährleistungsansprüche geltend gemacht werden.
3
Lieferumfang
Speicher-Print am Print RECERBO
Erforderliche Werkzeuge und Hilfsmittel
4
-
Torx-Schraubendreher TX25 kleiner Schlitz-Schraubendreher Hand Drehmoment-Schrauber Bit-Einsatz TX25
DE
Print RECERBO wechseln Wechselrichter öffnen
1
2 AC
1
OFF
I 0
2
1
3
3 2
3
Vorhandene DATCOM-Komponenten vom Wechselrichter trennen
4
5
4 4 4
1 2
4x TX25 2
3
1
5
4 3
110 mm
5
1
Stecker (2) mittels kleinem SchlitzSchraubendreher entfernen
2
Print-Halterungen (3) und (4) mit dem Print RECERBO (1) nach oben schieben
3
Print RECERBO Richtung Wechselrichter-Oberkante herausziehen
3
Print ausbauen
(1)
2
2 1
(2) (3) (4)
Ausgebauter Print RECERBO mit Montage-Konsole
6
1
(3)
1
Klemmnasen (1) und (3) nach außen drücken
2
Print RECERBO (2) aus der MontageKonsole klappen
DE
Speicher-Print aufstecken
2
(2)
1
(1)
VORSICHT! Beschädigungsgefahr für Wechselrichter durch das Aufstecken eines falschen Speicher-Prints. Das Aufstecken eines falschen Speicher-Prints kann zur Überhitzung von verschiedenen elektronischen Bauteilen führen. Hieraus können thermische Schäden resultieren, die in Folge zu Bränden führen können. Beim Aufstecken eines Speicher-Prints darauf achten, dass das Leistungs-Limit des Speicher-Prints der Leistungsklasse des Wechselrichters entspricht: Für Fronius Galvo 1.5 und 2.0 nur Speicher-Prints mit einem Leistungs-Limit 2,0 kW verwenden! Im Austauschfall Leistungsschilder der Wechselrichter beachten und vergleichen!
(4)
WICHTIG! Beim Anstecken des SpeicherPrints darauf achten, dass alle Pins des Prints RECERBO ordnungsgemäß in den entsprechenden Anschlussbuchsen des Speicher-Prints positioniert sind.
3
Speicher-Print am Print RECERBO an den Pins (4) anstecken
7
WICHTIG! Der an den Pins (4) angesteckte Speicher-Print hat Priorität gegenüber einem eventuell noch am Print RECERBO vorhandenen Speicher-Print. Der an den Pins (4) angesteckte SpeicherPrint gibt somit die eingestellten Daten, die Leistungsdaten und das Länder-Setup für den Wechselrichter vor.
Print RECERBO mit aufgestecktem Speicher-Print
4
Print RECERBO (2) in die MontageKonsole einklappen und die Klemmnasen (1) und (3) einrasten lassen
1
Print RECERBO in Richtung Wechselrichter-Unterkante in den Wechselrichter einsetzen. Die Print-Halterungen (3) und (4) in die dafür vorgesehenen Öffnungen einsetzen.
2
Print-Halterungen (3) und (4) mit dem Print RECERBO (1) bis auf Anschlag nach unten drücken
3
Stecker (2) anbringen
(3)
1
(2)
(1)
1
Print einbauen
(1)
2
2 3
(2) (3) (4)
8
1
2 1
DE
Wechselrichter schließen
1
1
2 3
4x TX25
1
4
4
5
2
2
2,5 Nm
3
2 Nm
3
110 mm
Vorhandene DATCOM-Komponenten wieder am Wechselrichter anschließen
5
4
AC
ON 2
I 0
1 2
2 Nm
1
3
3
9
10
General ...................................................................................................................................................... Safety.................................................................................................................................................... ESD guidelines ..................................................................................................................................... Scope of supply .................................................................................................................................... Required tools and material .................................................................................................................. Replacing the RECERBO PC Board.......................................................................................................... Opening the Inverter ............................................................................................................................. Removing the PC Board ....................................................................................................................... Connecting the Memory PC Board ....................................................................................................... Installing PC Board ............................................................................................................................... Closing the Inverter...............................................................................................................................
13 13 13 14 14 15 15 16 17 18 19
11
EN
Contents
12
Safety
WARNING! An electric shock can be fatal. Danger due to grid voltage and DC voltage from solar modules. The DC main switch is only used to switch off power to the power stage set. Whenthe DC main switch is turned off, the connection area is still energized.. All maintenance and service work should only be carried out when the power stage set has been disconnected from the connection area. The separate power stage set area should only be disconnected from theconnection area after first being disconnected from the grid power. Maintenance and service work on the inverter power stage set should only be carried out by Fronius-trained personnel. WARNING! An electric shock can be fatal. Danger from residual voltage from capacitors. You must wait until the capacitors have discharged. Discharge takes 3 minutes. CAUTION! An inadequate grounding conductor connection can cause serious injuries to persons and damage to (or loss of) property. The housing screws provide an adequate grounding conductor connection for the housing ground and should not, under any circumstances, be replaced by different screws that do not provide a proper grounding conductor connection. CAUTION! The inverter can be damaged by soiling or water on the terminals and contacts of the connection area. When removing the power stage set, make sure that terminals and contacts in the connection area do not become soiled or wet. Protect the wall bracket from soiling and moisture during installation.
ESD guidelines
NOTE! Observe ESD guidelines when handling electronic components and PC boards. This primarily applies to ESD compatible Packaging Work surfaces Floors Seating Earthing facilities Handling No guarantee or warranty claims can be made in respect of any improperly handled electronic component or PC board.
13
EN
General
Scope of supply
Memory PC board at the RECERBO PC Board
Required tools and material
14
-
TX 25 screwdriver Small Slotted screwdriver Hand torque wrench TX 25 bit insert
Replacing the RECERBO PC Board 1
2 EN
Opening the Inverter
AC
1
OFF
I 0
2
1
3
3 2
3
Disconnect all available DATCOM components from the inverter
4
5
4 4 4
1 2
4x TX25 2
3
1
5
4 3
110 mm
15
1
Remove the plug (2) using a small sloted screwdriver
2
Slide up the PC board brackets (3) and (4) together with the RECERBO PC board (1)
3
Take out the RECERBO PC board towards inverter top
3
Removing the PC Board
(1)
2
2 1
(2) (3) (4)
Disassembled RECERBO PC board with mounting support
16
Connecting the Memory PC Board
1
Push clamping devices (1) and (3) outwards
2
Swing out the RECERBO PC board (2) from the mounting support EN
(3)
1
2
(2)
1
(1)
CAUTION! Danger of inverter-damage due to connecting an improper memory PC board. Connecting an improper memory PC board may cause overheating of several electronic components. This could cause thermal damage which can in turn lead to fires. When connecting a memory PC board, make sure that the power limit of the memory PC board corresponds to the power class of the inverter: For Fronius Galvo 1.5 and 2.0 only use memory PC boards with a power limit 2.0 kW! In the case of replacement consider and compare inverter ratting plates!
(4)
IMPORTANT! When connecting the memory PC board, make sure that all pins of the RECERBO PC board are positioned properly in appropriate connection sockets of the memory PC board.
3
Connect the memory PC board to the pins (4) of the RECERBO PC board
17
IMPORTANT! The memory PC board connected to the pins (4) has priority over a possibly still existing memory PC board of the RECERBO PC board. Thus the memory PC board connected to the pins (4) presets the set data, the power data and the country setup for the inverter.
RECERBO PC board with connected memory PC board
4
Swing the RECERBO PC board (2) back into the mounting support and let the clamping devices (1) and (3) snap in
1
Insert the RECERBO PC board into the inverter towards inverter bottom. Insert the PC board brackets (3) and (4) into the foreseen holes.
2
Push down the PC board brackets (3) and (4) together with the RECERBO PC board (1) up to stop
3
Connect the plug (2)
(3)
1
(2)
(1)
1
Installing PC Board
(1)
2
2 3
(2) (3) (4)
18
1
2 1
1
1
EN
Closing the Inverter
2 3
4x TX25
1
4
4
5
2
2
2,5 Nm
3
2 Nm
3
110 mm
Reconnect all available DATCOM components to the inverter
5
4
AC
ON 2
I 0
1 2
2 Nm
1
3
3
19
20
EN 21
Fronius Worldwide - www.fronius.com/addresses
Fronius International GmbH 4600 Wels, Froniusplatz 1, Austria E-Mail:
[email protected] http://www.fronius.com
Fronius USA LLC Solar Electronics Division 6797 Fronius Drive, Portage, IN 46368 E-Mail:
[email protected] http://www.fronius-usa.com
Under http://www.fronius.com/addresses you will find all addresses of our sales branches and partner firms!