SENTRY RANGE INTRODUCTION CIRCUIT PROTECTION

CIRCUIT PROTECTION SENTRY RANGE INTRODUCTION The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its en...
0 downloads 2 Views 9MB Size
CIRCUIT PROTECTION

SENTRY RANGE INTRODUCTION

The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance mean it won’t look out of place when installed in hallways, lounges or kitchens of new properties. The expanded range includes a 21-module unit for larger installations and also a 4-module unit to cater for small one-off installations and extensions to existing ones.

SUPPORTS 17TH EDITION AMENDMENT 3 COMPLIANCE Full range of products to support compliance with the 17th Edition Amendment 3 of the Wiring Regulations, including Full Metal non-combustible enclosures for Consumer Units. MK ELECTRIC DESIGN SERVICE FOR PRE-ASSEMBLED CONSUMER UNITS Save time and money by specifying project requirements through the MK Electric Design Service. Pre-assembled custom built boards, with all devices pre-fitted with busbars and cables are available to suit any installation. FLOATING BUSBAR SYSTEM Gives maximum installation flexibility. BROAD SELECTION OF PRE-ASSEMBLED SPLIT LOAD UNITS AVAILABLE Suits a variety of applications and saves installation time.

HOW TO SPECIFY The MK Electric Design Service offers a preassembly service for custom built boards with all devices fitted, busbars cut and fitted with devices, live and neutral cables terminated.

A metal range of consumer unit and accessories (Switch’s MCB’s, RCD’s & RCBO’s) designed to comply to the 17th Edition Amendment 3 of the wiring regulations (BS 7671:2008). Consumer unit doors must be top hinged to ensure the door is closed when the unit is not in use. The base, lid & door of the consumer unit must be earthed to provide safe operation at all times. A floating busbar system to be employed to ensure maximum installation flexibility and acceptance of control devices. All consumer units must have a curved door to prevent dust collection and offer a unobtrusive appearance that blends into the environment. Backed out captive screws, removable DIN rails and sufficient wiring space are required to ensure ease of installation and maintenance.

MK Electric Catalogue

271

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

MK Sentry Consumer Unit Features and Benefits

NEW: Top Hinged Door Prevents door being left open after use leading to a possible fire risk

NEW: Manufactured from Zintec Steel Corrosion resistant material which ensures full compliance with 17th Edition Amendment 3

NEW: Multiple extra large knock outs Aides and eases installation

NEW: Continual Earthing Only need to earth once via the base

Curved Stylish Design Broad Selection Available NEW: MK White Colour Modernised aesthetics for visible installations. Design service available for bespoke requests

272

mkelectric.co.uk

Suits a variety of applications

Blends into the environment

Backed out and captive combi-head screws

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

Fixing holes

Allows simple and speedy installation

Easily removable Din Rail Simplifying and easing first fix

Tripod fixing to cope with uneven surfaces

Colour coded earth and neutral terminal locked At top of unit for ease of wiring

NEW: 10mm Increased Height Additional wiring space

NEW: Supporting Din Rail “T” Bar Additional support to prevent bowing and twisting which has been raised for improved cable routing

Floating busbar system For maximum installation flexibility including acceptance of control modules

CONSUMER UNIT SELECTION GUIDE STEP 1

Determine the type of consumer unit configuration required. e.g Split Load, Standard or combination of split load / single RCD or dual RCD. For each Switch Disconnector or RCD to be used allow 2 modular ways.

STEP 2

Determine the number of outgoing circuits required. e.g Cooker, Lighting, Ring Main etc. For each circuit to be protected by an MCB or RCBO allow 1 modular way.

STEP 3

Determine what control products are required. e.g Bell Transformer, Time Delay Switch, contactors, timeswitches etc.

STEP 4

Determine the number of ‘spare’ modular ways required for future upgrades. For each ‘spare’ modular way select 1 Sentry blank module – 5544s or K5545sMAG (cover mounted blanks supplied with consumer units. See page 286).

STEP 5

Now add together the total number of modular ways required.

STEP 6

Select from our range of Insulated, Metal, Flush or stacked consumer units (using standard consumer units plus stacking kits). Choose the type and size most appropriate for your requirements.

Offset Incomer Provides additional wiring space making mains input connections easier

MK Electric Catalogue

273

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

The MK Electric Design Service THE MK ELECTRIC DESIGN SERVICE IS PERFECT FOR WHEN ONLY A CUSTOMISED SOLUTION CAN MEET YOUR REQUIREMENTS, OR WHEN FULLY ASSEMBLED CONSUMER UNITS CAN BE PROVIDED FOR YOUR PROJECT TO SAVE YOU INSTALLATION TIME.

Our dedicated team can help you to build the best configurations for your project, and then assemble the boards ready for installation. Using standard and non-standard Sentry components we can build and supply fully assembled units to an agreed design. For example, have your split load boards supplied with all the devices pre-fitted with busbars and cables to suit the installation This service is ideal for housing developers, or any project application*. *Minimum order quantity of 20 of the same design



Dedicated team on hand to build configuration to meet your needs



Service is available for all MK Consumer Units



Faster installation time on site



Fast turnaround – 1 working day response time to initial enquiry

To find out more visit www.mkelectric.co.uk and follow the links to the Design Service.

274

STEP 1

Call the MK Electric Technical Services Team on 01268 563720 or email [email protected]

STEP 2

Discuss the details of your project and circuit protection requirements with a member of the MK Technical Services Team or complete the online enquiry and click send

STEP 3

Within one working day you will have a response to your initial enquiry

STEP 4

Confirm the configurations and quantities

STEP 5

Receive the quote for your order

STEP 6

Place your order with your wholesaler

STEP 7

Your order will be delivered to the wholesaler of your choice. All boards will be fully assembled and ready for installation

mkelectric.co.uk

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

Consumer Units METAL ENCLOSURE + SWITCH DISCONNECTOR SURFACE

METAL ENCLOSURE ONLY SURFACE

K5704sMET K5604sMET

K5716sMET

K5616sMET

K5708sMET K5608sMET

K5621sMET K5721sMET

K5712sMET

K5612sMET

K5604SMET1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)

K5608SMET1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)

K5612SMET1 12 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)

All units are white coloured. All units feature a robust galvanized metal base, lid & door. The DIN rail embodies a useful alignment and fixing mechanism that allows quick installation. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY

Width 144 238 310 382 472

x x x x x

Height 244 244 244 244 244

x x x x x

K5616SMET1

K5704SMET1

K5716SMET1

K5621SMET1

K5708SMET1

K5721SMET1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 19 ONE MODULE PRODUCTS

16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)

4 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS 8 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 6 ONE MODULE PRODUCTS

16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 14 ONE MODULE PRODUCTS

K5712SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3

Depth 116mm 116mm 116mm 116mm 116mm

FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components

All units are pre-fitted with a switch disconnector DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY

Width 144 238 310 382 472

x x x x x

Height 244 244 244 244 244

x x x x x

Depth 116mm 116mm 116mm 116mm 116mm

MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3

Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 and 12 way enclosures and 2 off x 2 for 16 and 21 way enclosures)

MK Electric Catalogue

275

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

Consumer Units SPLIT-LOAD SINGLE RCD ARRANGEMENTS METAL SURFACE

K5682sMET

SPLIT-LOAD DUAL RCD ARRANGEMENTS METAL SURFACE

K5662sMET

K5666sMET

K5687sMET

K5682SMET 1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS

K5662SMET

1

K5666SMET 1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS

K5683SMET

K5689SMET

K5685SMET

1

K5688SMET

1

K5687SMET 1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS

K5684SMET

1

K5686SMET

1

K5681SMET

16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS

1

12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 17 ONE MODULE PRODUCTS

All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY

276

Width Height Depth 144 x 244 x 116mm

8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3

FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components

16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS

All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY

Width Height Depth 144 x 244 x 116mm

21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS

21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS

1

1

8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3

Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 & 2 way enclosures and 2 off x 2 for 16 & 21 way enclosures)

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

FULLY POPULATED ARRANGEMENTS METAL SURFACE

K6550sMET

K7673sMET

K6551sMET

K7663sMET

K7665sMET

K6552sMET

K7664sMET

K7666sMET

K7678sMET

K6550SMET1

K7673SMET1

K6551SMET1 4 WAY ENCLOSURE 63A 30mA RCD 1 X MCB (1 X 50A)

4 WAY ENCLOSURE 63A 30mA RCD 2 X MCB’S (1 X 6A & 1 X 16A)

K7663SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD 6 X MCB’S (2 X 6A, 2 X 16A & 2 X 32A) 2 X RCBO’S (1 X 6A & 1 X 40A)

K7664SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 6 X MCB’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A)

All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded.

12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 6 X RCBO’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A) ACCEPTS A FURTHER 4 ONE MODULE PRODUCTS

K7665SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 8 X MCB’S (2 X 6A, 2 X 16A, 3 X 32A & 1 X 40A) ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS

K7666SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 10 X MCB’S (3 X 6A, 2 X 16A, 4 X 32A & 1 X 40A)

MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY

Width 144 238 310 382 472

x x x x x

Height 244 244 244 244 244

x x x x x

Depth 116mm 116mm 116mm 116mm 116mm

K6552SMET1 8 WAY ENCLOSURE 63A 30mA RCD 6 X MCB’S (3 X 6A, 1 X 16A & 2 X 20A)

K7678SMET1 21 WAY ENCLOSURE 1 X 63A & 1 X 80A 30mA RCD’S 12 X MCB’S (3 X 6A, 2 X 16A, 2 X 20A, 4 X 32A & 1 X 40A) ACCEPTS A FURTHER 3 ONE MODULE PRODUCTS

MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3

FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components

MK Electric Catalogue

277

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

Consumer Units

Switch Disconnectors Double Pole

INSULATED SURFACE

TWO MODULE

K5604sMAG

K5612sMAG

5500s

K5608sMAG

K5616sMAG

K5621sMAG

K5604SMAG1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)

K5608SMAG1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)

All units are magnolia coloured. All units feature a robust base together with an all over front cover and moulded lid in an impact resistant, flame retardant thermoplastic. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: K5604sMAG K5608sMAG K5612sMAG K5616sMAG K5621sMAG

Width 140 234 306 378 468

x x x x x

Height 230 230 230 230 230

x x x x x

Depth 110mm 110mm 110mm 110mm 110mm

MAIN INCOMER MAXIMUM RATING K5604sMAG and K5504sMAG: 63A All other consumer units: 100A

K5612SMAG1 12 WAY ENCLOSURE ACCEPTS 12 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINK)

K5616SMAG1 16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINK)

K5621SMAG1 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (4 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)

K5687SMAG17ED1 Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. use of cable glands and knockouts. BS EN 60439-3:1999

FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components

278

mkelectric.co.uk

5560s

5500s5 100A 230V

5560s5 63A 230V

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Accepts direct to busbar or cable-in / cable-out connection. CATEGORY OF DUTY: AC22A for switching of resistive and inductive loads. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 81 x 36 x 76mm CABLE CAPACITY: 50mm² BS EN 60947-3:1999

MCBs Single Pole

MCB Single Pole

TYPE B ONE MODULE

TYPE C ONE MODULE

5903s

5910s

5906s

5916s

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

5920s

5945s

5940s 8703s

8706s

8720s

8732s

8710s

8716s

8740s

8750s

5950s

5903s10

5920s10 20A 230V

3A 230V

8703s10

8720s10

5906s10

5925s10

8706s10

8725s10

5910s10

5932s10

8710s10

8732s10

5916s10

5940s10

8716s10

8740s10

3A 230V 6A 230V

10A 230V 16A 230V

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² Short-circuit breaking capacity: 6KA BS EN 60898:2003

25A 230V 32A 230V 40A 230V

5945s10 45A 230V

5950s10 50A 230V

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003

6A 230V

10A 230V 16A 230V

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003

20A 230V 25A 230V 32A 230V 40A 230V

8750s10 50A 230V

8763s10 63A 230V

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003

MK Electric Catalogue

279

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

RCBOs With Solid Neutral Single Pole

Residential 6kA RCD Double Pole Type AC

TYPE B ONE MODULE

7932s

16 AMP TWO MODULE

TYPE C ONE MODULE

7933s

7934s

7935s

8932s

8933s

8934s

7816s

7936s

7937s

7932s1

6A 230V 30mA TRIPPING CURRENT

7933s1 10A 230V 30mA TRIPPING CURRENT

7934s1 16A 230V 30mA TRIPPING CURRENT

Suitable for installation in Sentry Consumer Units. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 119 x 18 x 73mm CABLE CAPACITY: Live 25mm², Neutral 25mm² SHORT CIRCUIT BREAKING CAPACITY: 6KA BS EN 61009-1 BS IEC 61009-2-2

280

mkelectric.co.uk

7938s

7939s

7935s1 20A 230V 30mA TRIPPING CURRENT

7936s1 32A 230V 30mA TRIPPING CURRENT

7937s1 40A 230V 30mA TRIPPING CURRENT

7938s1 45A 230V 30mA TRIPPING CURRENT

7939s1 50A 230V 30mA TRIPPING CURRENT

8935s

8936s

8932s1 6A 230V 30mA TRIPPING CURRENT

8933s1 10A 230V 30mA TRIPPING CURRENT

8934s1 16A 230V 30mA TRIPPING CURRENT

8935s1 20A 230V 30mA TRIPPING CURRENT

8936s1 32A 230V 30mA TRIPPING CURRENT

7816s1 16A 230V 30mA TRIPPING CURRENT

32 AMP TWO MODULE

7832s

7832s1 32A 230V 30mA TRIPPING CURRENT

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

40 AMP TWO MODULE

63 AMP TWO MODULE

80 AMP TWO MODULE

7860s

7880s

7660s

7680s

7860s1

7880s1

7560s1

7580s1

7840s

7840s1 40A 230V 30mA TRIPPING CURRENT

63A 230V 30mA TRIPPING CURRENT 63A 230V 100mA TRIPPING CURRENT

7660s1 63A 230V 300mA TRIPPING CURRENT

80A 230V 30mA TRIPPING CURRENT

80A 230V 100mA TRIPPING CURRENT

7680s1 80A 230V 300mA TRIPPING CURRENT

MK Electric Catalogue

281

CIRCUIT PROTECTION

Sentry

mkelectric.co.uk

Industrial 10kA RCDs Double Pole Type AC 16 AMP TWO MODULE

32 AMP TWO MODULE

6016s

6032s

6316s

6730s

6016s1

6032s1

6416s1

6730s1

16A 110V 10mA TRIPPING CURRENT 16A 110V 30mA TRIPPING CURRENT

32A 110V 30mA TRIPPING CURRENT 32A 230V 30mA TRIPPING CURRENT

6316s1 16A 230V 10mA TRIPPING CURRENT

5716s1 16A 230V 30mA TRIPPING CURRENT

282

mkelectric.co.uk

40 AMP TWO MODULE

5740s

5740s1 40A 230V 30mA TRIPPING CURRENT

63 AMP TWO MODULE

80 AMP TWO MODULE

100 AMP TWO MODULE

5760s

6080s

6600s

5860s

5880s

7800s

5760s1

6080s1

7700s1

6160s1

5780s1

6600s1

5860s1

6180s1

7800s1

63A 230V 30mA TRIPPING CURRENT

63A 230V 100mA TRIPPING CURRENT 63A 230V 300mA TRIPPING CURRENT

80A 110V 30mA TRIPPING CURRENT 80A 230V 30mA TRIPPING CURRENT

80A 230V 100mA TRIPPING CURRENT

5880s1 80A 230V 300mA TRIPPING CURRENT

100A 230V 30mA TRIPPING CURRENT

100A 230V 100mA TRIPPING CURRENT 100A 230V 300mA TRIPPING CURRENT

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm² BS EN 61008:1995

Industrial 10kA RCDs Pulsating d.c. Fault Current Sensitive Double Pole Type A

Industrial 10kA RCDs Time Delayed Double Pole

TWO MODULE

TWO MODULE

6216s

5640s

6980s

6630s

6216s1 16A 230V 10mA TRIPPING CURRENT

6630s1 32A 230V 30mA TRIPPING CURRENT

5640s1 40A 230V 30mA TRIPPING CURRENT

5660s1 63A 230V 30mA TRIPPING CURRENT

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

Industrial 10kA RCDs Four Pole Type AC 25 AMP FOUR MODULE

6425s

80A 230V 100mA TRIPPING CURRENT TIME DELAYED

6400s1 100A 230V 100mA TRIPPING CURRENT TIME DELAYED

Suitable for installation in Sentry Consumer Units and Four Module enclosures. When used as a mains incomer these units will provide discrimination with downstream instantaneously operating 10mA or 30 mA RCD’s. For example, they can be used as main incomers on split load consumer units where it is not desirable, because of the possibility of unwanted tripping, to place all of the circuits on an instantaneous 30mA RCD, but where earth leakage protection is still required for these circuits or where compliance is required to the indirect contact protection requirements of the IET Wiring Regulations.

6440s

6240s

6400s

6980s1

40 AMP FOUR MODULE

6425s1

25A 230/400V 30mA TRIPPING CURRENT

Suitable for installation in Sentry four module enclosures and Commando Combi. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995

6440s1 40A 230/400V 30mA TRIPPING CURRENT

6240s1 40A 230/400V 100mA TRIPPING CURRENT

DIMS: 81 x 36 x 76mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 NOT TO BE USED FOR PERSONAL PROTECTION AGAINST ELECTRIC SHOCK

FACTORY BUILT SERVICE MK can save you time and money by pre-assembling consumer units with your required Sentry components

MK Electric Catalogue

283

CIRCUIT PROTECTION

Sentry Industrial 10kA RCDs Four Pole Type AC 63 AMP FOUR MODULE

6463s

mkelectric.co.uk

Industrial 10kA RCD Contactors Pulsating d.c. Fault Current Sensitive, Four Pole Type A FOUR MODULE

6640s

6363s

6463s1

63A 230/400V 30mA TRIPPING CURRENT

6363s1 63A 230/400V 100mA TRIPPING CURRENT

6263s1 63A 230/400V 300mA TRIPPING CURRENT

6640s1 40A 230/400V 30mA TRIPPING CURRENT

Suitable for installation in Sentry two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995

ONE MODULE

TWO MODULE

THREE MODULE

6220s

7240s

7440s

6720s

7263s

7463s

20A DOUBLE POLE

20A FOUR POLE

6420s1

7440s1

6720s1

7240s1

7463s1

6220s1

20A DOUBLE POLE WITH MANUAL OVERRIDE

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Automatically switches higher loads than possible with a time switch eg; off peak tariffs. A manual override enables the temporary setting of the contactor in either the on or off position in addition to normal automatic operation. When a contactor is mounted alongside an MCB of greater than 10 amp current rating or two contractors are mounted alongside an MCB or side by side, it is necessary to insert a blank module between them (list no.5544s)

40A DOUBLE POLE

40A FOUR POLE 63A FOUR POLE

7263s1 63A DOUBLE POLE

CONTACTOR RATINGS: List no

6220s 6420s 6720s

7240s 7440s

7263s 7463s

RATED CURRENT Ith

20A

40A

63A

5.4kW 16kW

8.6kW 26kW

13.6kW 41kW

1.1kW 4kW

2.2kW 7.5kW

4kW 11kW

2,800W 2,000W

7,000W 4,200W

10,000W 6,300W

VOLTAGE RATING (coil)

230V 50Hz

230V 50Hz

230V 50Hz

CABLE CAPACITY

6mm2 rigid

25mm2 rigid

25mm2 rigid

6220S: 84 x 18 x 66mm 7240S: 84 x 36 x 66mm 7463S: 84 x 54 x 66mm

6420S: 84 x 36 x 66mm 7263S: 84 x 36 x 66mm

6720S: 84 x 18 x 66mm 7440S: 84 x 54 x 66mm

HEATING

Single phase 230V Three phase 400V MOTORS Single phase 230V Three phase 400V LIGHTING

Incandescent and Halogen lamps: Fluorescent Lamps: (Electronic Ballast)

BS EN 61095 DIMENSIONS:

284

mkelectric.co.uk

(including half module blank)

Bell Transformer

TWO MODULE

5711s

CIRCUIT PROTECTION

Sentry

Technical Hotline +44 (0)1268 563720

Time Switches DIGITAL ONE CHANNEL TWO MODULE

DIGITAL ONE CHANNEL ONE MODULE

SYNCHRONOUS THREE MODULE

QUARTZ STABILISED THREE MODULE

SYNCHRONOUS ONE MODULE

5707s

5824s

5833s

5731s

5733s

5732s

5824s1

5833s1

5731s1

5733s1

5732s1

Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures. Power reserve 150 hours VOLTAGE RATING: 220-240Va.c. 50-60Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993

Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 90 x 18 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993

Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment, holiday programme and random generator are standard facilities. Power reserve of 150 hours. Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 90 x 18 x 74mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993

Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993

DIGITAL TWO CHANNEL TWO MODULE

5724s

5711s1 RATING 1A AT 8V PRIMARY 220 – 240V A.C.50HZ Suitable for installation in Sentry Consumer Units and two or four module enclosures. NOTE: When installed in a consumer unit, ensure that output cables inside the enclosures are suitable for a 230V environment, either by sleeving the bell wire to BS 2848 or using 230V cable. Complete with terminal covers. Also suitable for surface mounting. DIMENSIONS: 88 x 36 x 67mm CABLE CAPACITY: 1 x 2.5mm2 EN 61558-2-8

5707s1

7 DAY DIAL MIN SETTING 3 HOURS

5724s1 24 HOUR DIAL MIN SETTING 30 MINUTES

Suitable for DIN rail mounting in Sentry Consumer Units or four module enclosures. VOLTAGE RATING: 220-240Va.c. 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2

24 HOUR DIAL MIN SETTING 30 MINUTES

24 HOUR DIAL MIN SETTING 30 MINUTES

24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE

Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993

24 HOUR DIAL MIN SETTING 1 MINUTE

24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE

MK Electric Catalogue

285

CIRCUIT PROTECTION

Sentry Time Delay Switches

mkelectric.co.uk

Consumer Unit Cable Kits

Accessories

ONE MODULE

PUSH LEVER UP TO SWITCH ON RCBO

TEST BUTTON PUSH LEVER UP TO SWITCH ON

10

11

12

13

14

15

16

18

19

20

21

22

23

24

2

14

RCD PROTECTED CIRCUITS

RCD PROTECTED CIRCUITS

TEST QUARTERLY

TEST QUARTERLY

3

4

5

6

17

18

7

8

19

20

9

10

SWITCH

1

2

3

9 17

4

5

10

11

12

13

18

19

20

21

RCD PROTECTED CIRCUITS

1

2

14

(Cut as required)

12

13

22

23

24

15

U1

16

U2

SOCKETS GROUND FLOOR

SOCKETS FIRST FLOOR

K8041s

K5545sMAG

24

TEST QUARTERLY

4

5

6

17

18

7

8

19

20

9

10

21

LIGHTS OUTSIDE

RING CIRCUIT KITCHEN

RING CIRCUIT

SECURITY OUT ALARM BUILDING

220-250V 50Hz a.c.

220-250V 50Hz a.c.

SHOWER

SHOWER

SECURITY ALARM

RATED CURRENT MUST NOT EXCEED 63A MAX

RATED CURRENT MUST NOT EXCEED 100A MAX

SMOKE ALARM

CLEAN EARTH

DOOR BELL

4 module unit

CENTRAL HEATING

FRIDGE

COOKER

COMPUTER

SMOKE ALARM

LIGHTS

KITCHEN SOCKETS

LIGHTS

GARAGE SOCKETS

GARAGE LIGHTS

ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY

DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER

OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3

12

13

22

23

24

15

U1

16

U2

U3

H Main Switches Warning Labels

ON

IMPORTANT

SOCKETS

LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR

RING CIRCUIT FIRST FLOOR

WATER HEATER

SOCKETS

WARNING

SOCKETS SECOND FLOOR

LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR

WATER HEATER

(Cut as required)

11

ON

STORAGE STORAGE HEATER HEATER

LIGHTS BASEMENT RING CIRCUIT BASEMENT

FREEZER

LIGHTS FIRST FLOOR

21

H Main Switches Warning Labels

OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3

WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER

SOCKETS BASEMENT

SOCKETS GROUND FLOOR

SOCKETS FIRST FLOOR

LIGHTS OUTSIDE

RING CIRCUIT KITCHEN

RING CIRCUIT

SECURITY OUT ALARM BUILDING

220-250V 50Hz a.c.

220-250V 50Hz a.c.

SHOWER

SHOWER

SECURITY ALARM

RATED CURRENT MUST NOT EXCEED 63A MAX

RATED CURRENT MUST NOT EXCEED 100A MAX

SMOKE ALARM

CLEAN EARTH

DOOR BELL

4 module unit

CENTRAL HEATING

FRIDGE

COOKER

COMPUTER

SMOKE ALARM

K5597s

LIGHTS

KITCHEN SOCKETS

LIGHTS

GARAGE SOCKETS

IMPORTANT

SOCKETS

LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR

RING CIRCUIT FIRST FLOOR

WATER HEATER

SOCKETS

WARNING

SOCKETS SECOND FLOOR

LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR

WATER HEATER

LIGHTS FIRST FLOOR

ON

STORAGE STORAGE HEATER HEATER

LIGHTS BASEMENT RING CIRCUIT BASEMENT

FREEZER

8, 12, 16 & 21 module units

This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.

5650s

8 16

23

RCD PROTECTED CIRCUITS

3

G Individual Circuit Labels

5544s

7 15

22

TEST QUARTERLY

F Circuit ID Labels

U3

RCD TIME DELAYED

11

ON

5562s

6 14

RCD PROTECTED CIRCUITS

TEST QUARTERLY

MAIN

SWITCH

F Circuit ID Labels

SOCKETS BASEMENT

B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit.

1 2 3 4 5 6 7 8 9 10 11 12 13 14

RCD TIME DELAYED

1

RCBO

TEST BUTTON

RCD

ADDITIONAL INFORMATION

8

TEST QUARTERLY

PUSH LEVER UP TO SWITCH ON

PUSH LEVER UP TO SWITCH ON

Pantone 355

CIRCUIT NUMBER

7

RCD PROTECTED CIRCUITS

Pantone Black

E Additional Information Label

6

A RESETTING INSTRUCTION LABEL

ADDITIONAL INFORMATION

5

CIRCUIT NUMBER

4

MAIN

Mid-Trip Off

Pantone 102

Pantone Blue??

If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720.

3

E Additional Information Label

9 17

TEST BUTTON

On

MCB

RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected.

Pantone 485

This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice.

RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on".

B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit.

RCD

1 2 3 4 5 6 7 8 9 10 11 12 13 14 2

MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320

SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer

If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720.

A RESETTING INSTRUCTION LABEL

1

Ref: Ono: Our Ref: Date: Version: Size:

WARNING

Pantone 355

GARAGE LIGHTS

DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER

ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY

OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3

OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3

WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER

8, 12, 16 & 21 module units

G Individual Circuit Labels

This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.

K5599s

K5563s

K6061SMET

K5511s

5650s1

DELAY RANGE 1 - 7 MINUTES (APPROX)

Suitable for installation in Sentry Consumer Units and two or four module enclosures. Offers time delay control for complete circuits of either tungsten or fluorescent lighting with any number of standard push switches. It can also be used to control fans in bathrooms without a window. Delay setting can be over-ridden by setting to ‘Perm-on’ mode, or by fitting a remote overriding switch. Switch has a switching capacity of 16A Resistive loads (upf) Fluorescent lamps uncompensated Series compensated 1300W Parallel compensated 480W CFLS 100W Max. Maximum of 9 units can be connected Incandescent lamps 2000W Neon glow lamp load (locating lamp for Push Switch) 50mA max VOLTAGE RATING: 230V 50Hz DIMENSIONS: 84 x 18 x 70mm CABLE CAPACITY: 1 x 4mm2or 2 x 1.5mm2

286

mkelectric.co.uk

K5565s

K5593s

KAX26s

K6062SMET

K5563s5

5562s1

5544s5

K5597s5

SPLIT-LOAD KIT CONSISTS OF 3 CABLES (2 NEUTRAL AND 1 LIVE) FOR USE WHEN ASSEMBLING A SPLIT LOAD ARRANGEMENT

K5565s5 MULTI-INCOMER KIT CONSISTS OF A BLUE FLEXIBLE CABLE WITH PRE-FITTED TERMINAL FOR THE NEUTRAL RETURN FROM SWITCH OR RCD TO SECOND OR THIRD NEUTRAL BAR

K5568s5 17TH EDITION CABLE KIT FOR SWITCH AND TWIN RCD ARRANGEMENT

K5567s5 A&D CABLE KIT FOR SWITCH PLUS TRIPLE RCD ARRANGEMENT

K5563S For use when assembling split-load arrangement. K5565S For use when assembling a consumer unit in a multi-incomer arrangement with separate supply to each incomer. These kits must be used to ensure compliance with BS EN 60439-3

EXTENSION TERMINAL FOR USE WHEN ASSEMBLING A CONSUMER UNIT AS A DISTRIBUTION BOARD. ENABLES DIRECT CONNECTION OF CABLES TO THE NEUTRAL BAR. CONSISTS OF A 25MM2 CAPACITY TERMINAL WITH CLAMP SCREW

K8041s10 LOCKING DEVICE FOR USE WHEN LOCKING A SENTRY MCB, RCBO, RCD OR SWITCH DISCONNECTOR IN EITHER THE ON OR OFF POSITION

K5593s

BARREL LOCK AND KEY KIT SUITABLE FOR SECURING ‘K’ SERIES SENTRY CONSUMER UNIT LIDS. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS

1

MCB BLANK – GREY DESIGNED TO FILL UNUSED MODULES IN SENTRY CONSUMER UNITS AND SMALL ENCLOSURES. DIN-RAIL MOUNTED

K5545sMAG10 COVER MOUNTED BLANK FOR FILLING SPACES IN THE ‘K’ SERIES SENTRY CONSUMER UNIT COVER, WHERE THERE ARE UNUSED MODULES

K5511s1 BUSBAR 11 MODULE

K5590s1 BUSBAR 20 MODULE

KAX26s10 BUSBAR COVER SUITABLE FOR INSULATING THE BUSBARS K5511S AND K5590S 20 MODULE. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS

ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER

Mid-Trip Off

Pantone Black

C Busbar Shield Warning Label (Factory fitted)

TEST BUTTON

On

MCB

RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected.

Pantone 102

Pantone Blue??

WARNING

RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on".

Pantone 485

This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice.

ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER

MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320

SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer

C Busbar Shield Warning Label (Factory fitted)

Ref: Ono: Our Ref: Date: Version: Size:

CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON DUAL & TRIPLE RCD BOARDS

K5599s5 CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON SINGLE RCD BOARDS

K5804sD1MAG K5808sD1MAG K5812sD1MAG K5816sD1MAG K5821sD1MAG

REPLACEMENT PLASTIC FRONT COVERS

K6060SMET1 16 WAY METAL CONSUMER UNIT SURFACE MOUNTING KIT

K6061SMET1 12 WAY METAL CONSUMER UNIT STACKING KIT

K6062SMET1 16 WAY METAL CONSUMER UNIT STACKING KIT

ASPECT DOUBLE SOCKET – BESPOKE FINISH

Available on a worldwide basis, the MK Design Service is supported by a dedicated team to ensure the seamless delivery of your chosen products. To find out more visit www.mkelectric.co.uk

MK Electric Catalogue

287

PRODUCT

APPLICATION

PRODUCT APPLICATION