CIRCUIT PROTECTION
SENTRY RANGE INTRODUCTION
The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance mean it won’t look out of place when installed in hallways, lounges or kitchens of new properties. The expanded range includes a 21-module unit for larger installations and also a 4-module unit to cater for small one-off installations and extensions to existing ones.
SUPPORTS 17TH EDITION AMENDMENT 3 COMPLIANCE Full range of products to support compliance with the 17th Edition Amendment 3 of the Wiring Regulations, including Full Metal non-combustible enclosures for Consumer Units. MK ELECTRIC DESIGN SERVICE FOR PRE-ASSEMBLED CONSUMER UNITS Save time and money by specifying project requirements through the MK Electric Design Service. Pre-assembled custom built boards, with all devices pre-fitted with busbars and cables are available to suit any installation. FLOATING BUSBAR SYSTEM Gives maximum installation flexibility. BROAD SELECTION OF PRE-ASSEMBLED SPLIT LOAD UNITS AVAILABLE Suits a variety of applications and saves installation time.
HOW TO SPECIFY The MK Electric Design Service offers a preassembly service for custom built boards with all devices fitted, busbars cut and fitted with devices, live and neutral cables terminated.
A metal range of consumer unit and accessories (Switch’s MCB’s, RCD’s & RCBO’s) designed to comply to the 17th Edition Amendment 3 of the wiring regulations (BS 7671:2008). Consumer unit doors must be top hinged to ensure the door is closed when the unit is not in use. The base, lid & door of the consumer unit must be earthed to provide safe operation at all times. A floating busbar system to be employed to ensure maximum installation flexibility and acceptance of control devices. All consumer units must have a curved door to prevent dust collection and offer a unobtrusive appearance that blends into the environment. Backed out captive screws, removable DIN rails and sufficient wiring space are required to ensure ease of installation and maintenance.
MK Electric Catalogue
271
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
MK Sentry Consumer Unit Features and Benefits
NEW: Top Hinged Door Prevents door being left open after use leading to a possible fire risk
NEW: Manufactured from Zintec Steel Corrosion resistant material which ensures full compliance with 17th Edition Amendment 3
NEW: Multiple extra large knock outs Aides and eases installation
NEW: Continual Earthing Only need to earth once via the base
Curved Stylish Design Broad Selection Available NEW: MK White Colour Modernised aesthetics for visible installations. Design service available for bespoke requests
272
mkelectric.co.uk
Suits a variety of applications
Blends into the environment
Backed out and captive combi-head screws
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
Fixing holes
Allows simple and speedy installation
Easily removable Din Rail Simplifying and easing first fix
Tripod fixing to cope with uneven surfaces
Colour coded earth and neutral terminal locked At top of unit for ease of wiring
NEW: 10mm Increased Height Additional wiring space
NEW: Supporting Din Rail “T” Bar Additional support to prevent bowing and twisting which has been raised for improved cable routing
Floating busbar system For maximum installation flexibility including acceptance of control modules
CONSUMER UNIT SELECTION GUIDE STEP 1
Determine the type of consumer unit configuration required. e.g Split Load, Standard or combination of split load / single RCD or dual RCD. For each Switch Disconnector or RCD to be used allow 2 modular ways.
STEP 2
Determine the number of outgoing circuits required. e.g Cooker, Lighting, Ring Main etc. For each circuit to be protected by an MCB or RCBO allow 1 modular way.
STEP 3
Determine what control products are required. e.g Bell Transformer, Time Delay Switch, contactors, timeswitches etc.
STEP 4
Determine the number of ‘spare’ modular ways required for future upgrades. For each ‘spare’ modular way select 1 Sentry blank module – 5544s or K5545sMAG (cover mounted blanks supplied with consumer units. See page 286).
STEP 5
Now add together the total number of modular ways required.
STEP 6
Select from our range of Insulated, Metal, Flush or stacked consumer units (using standard consumer units plus stacking kits). Choose the type and size most appropriate for your requirements.
Offset Incomer Provides additional wiring space making mains input connections easier
MK Electric Catalogue
273
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
The MK Electric Design Service THE MK ELECTRIC DESIGN SERVICE IS PERFECT FOR WHEN ONLY A CUSTOMISED SOLUTION CAN MEET YOUR REQUIREMENTS, OR WHEN FULLY ASSEMBLED CONSUMER UNITS CAN BE PROVIDED FOR YOUR PROJECT TO SAVE YOU INSTALLATION TIME.
Our dedicated team can help you to build the best configurations for your project, and then assemble the boards ready for installation. Using standard and non-standard Sentry components we can build and supply fully assembled units to an agreed design. For example, have your split load boards supplied with all the devices pre-fitted with busbars and cables to suit the installation This service is ideal for housing developers, or any project application*. *Minimum order quantity of 20 of the same design
•
Dedicated team on hand to build configuration to meet your needs
•
Service is available for all MK Consumer Units
•
Faster installation time on site
•
Fast turnaround – 1 working day response time to initial enquiry
To find out more visit www.mkelectric.co.uk and follow the links to the Design Service.
274
STEP 1
Call the MK Electric Technical Services Team on 01268 563720 or email
[email protected]
STEP 2
Discuss the details of your project and circuit protection requirements with a member of the MK Technical Services Team or complete the online enquiry and click send
STEP 3
Within one working day you will have a response to your initial enquiry
STEP 4
Confirm the configurations and quantities
STEP 5
Receive the quote for your order
STEP 6
Place your order with your wholesaler
STEP 7
Your order will be delivered to the wholesaler of your choice. All boards will be fully assembled and ready for installation
mkelectric.co.uk
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
Consumer Units METAL ENCLOSURE + SWITCH DISCONNECTOR SURFACE
METAL ENCLOSURE ONLY SURFACE
K5704sMET K5604sMET
K5716sMET
K5616sMET
K5708sMET K5608sMET
K5621sMET K5721sMET
K5712sMET
K5612sMET
K5604SMET1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)
K5608SMET1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)
K5612SMET1 12 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)
All units are white coloured. All units feature a robust galvanized metal base, lid & door. The DIN rail embodies a useful alignment and fixing mechanism that allows quick installation. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY
Width 144 238 310 382 472
x x x x x
Height 244 244 244 244 244
x x x x x
K5616SMET1
K5704SMET1
K5716SMET1
K5621SMET1
K5708SMET1
K5721SMET1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 19 ONE MODULE PRODUCTS
16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)
4 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS 8 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 6 ONE MODULE PRODUCTS
16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 14 ONE MODULE PRODUCTS
K5712SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3
Depth 116mm 116mm 116mm 116mm 116mm
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components
All units are pre-fitted with a switch disconnector DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY
Width 144 238 310 382 472
x x x x x
Height 244 244 244 244 244
x x x x x
Depth 116mm 116mm 116mm 116mm 116mm
MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3
Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 and 12 way enclosures and 2 off x 2 for 16 and 21 way enclosures)
MK Electric Catalogue
275
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Consumer Units SPLIT-LOAD SINGLE RCD ARRANGEMENTS METAL SURFACE
K5682sMET
SPLIT-LOAD DUAL RCD ARRANGEMENTS METAL SURFACE
K5662sMET
K5666sMET
K5687sMET
K5682SMET 1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS
K5662SMET
1
K5666SMET 1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS
K5683SMET
K5689SMET
K5685SMET
1
K5688SMET
1
K5687SMET 1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS
K5684SMET
1
K5686SMET
1
K5681SMET
16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS
1
12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 17 ONE MODULE PRODUCTS
All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY
276
Width Height Depth 144 x 244 x 116mm
8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components
16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS
All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY
Width Height Depth 144 x 244 x 116mm
21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS
21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS
1
1
8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3
Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 & 2 way enclosures and 2 off x 2 for 16 & 21 way enclosures)
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
FULLY POPULATED ARRANGEMENTS METAL SURFACE
K6550sMET
K7673sMET
K6551sMET
K7663sMET
K7665sMET
K6552sMET
K7664sMET
K7666sMET
K7678sMET
K6550SMET1
K7673SMET1
K6551SMET1 4 WAY ENCLOSURE 63A 30mA RCD 1 X MCB (1 X 50A)
4 WAY ENCLOSURE 63A 30mA RCD 2 X MCB’S (1 X 6A & 1 X 16A)
K7663SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD 6 X MCB’S (2 X 6A, 2 X 16A & 2 X 32A) 2 X RCBO’S (1 X 6A & 1 X 40A)
K7664SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 6 X MCB’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A)
All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded.
12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 6 X RCBO’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A) ACCEPTS A FURTHER 4 ONE MODULE PRODUCTS
K7665SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 8 X MCB’S (2 X 6A, 2 X 16A, 3 X 32A & 1 X 40A) ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS
K7666SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 10 X MCB’S (3 X 6A, 2 X 16A, 4 X 32A & 1 X 40A)
MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY
Width 144 238 310 382 472
x x x x x
Height 244 244 244 244 244
x x x x x
Depth 116mm 116mm 116mm 116mm 116mm
K6552SMET1 8 WAY ENCLOSURE 63A 30mA RCD 6 X MCB’S (3 X 6A, 1 X 16A & 2 X 20A)
K7678SMET1 21 WAY ENCLOSURE 1 X 63A & 1 X 80A 30mA RCD’S 12 X MCB’S (3 X 6A, 2 X 16A, 2 X 20A, 4 X 32A & 1 X 40A) ACCEPTS A FURTHER 3 ONE MODULE PRODUCTS
MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components
MK Electric Catalogue
277
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Consumer Units
Switch Disconnectors Double Pole
INSULATED SURFACE
TWO MODULE
K5604sMAG
K5612sMAG
5500s
K5608sMAG
K5616sMAG
K5621sMAG
K5604SMAG1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)
K5608SMAG1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR)
All units are magnolia coloured. All units feature a robust base together with an all over front cover and moulded lid in an impact resistant, flame retardant thermoplastic. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: K5604sMAG K5608sMAG K5612sMAG K5616sMAG K5621sMAG
Width 140 234 306 378 468
x x x x x
Height 230 230 230 230 230
x x x x x
Depth 110mm 110mm 110mm 110mm 110mm
MAIN INCOMER MAXIMUM RATING K5604sMAG and K5504sMAG: 63A All other consumer units: 100A
K5612SMAG1 12 WAY ENCLOSURE ACCEPTS 12 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINK)
K5616SMAG1 16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINK)
K5621SMAG1 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (4 INTEGRAL NEUTRAL BARS FITTED WITH LINKS)
K5687SMAG17ED1 Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. use of cable glands and knockouts. BS EN 60439-3:1999
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components
278
mkelectric.co.uk
5560s
5500s5 100A 230V
5560s5 63A 230V
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Accepts direct to busbar or cable-in / cable-out connection. CATEGORY OF DUTY: AC22A for switching of resistive and inductive loads. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 81 x 36 x 76mm CABLE CAPACITY: 50mm² BS EN 60947-3:1999
MCBs Single Pole
MCB Single Pole
TYPE B ONE MODULE
TYPE C ONE MODULE
5903s
5910s
5906s
5916s
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
5920s
5945s
5940s 8703s
8706s
8720s
8732s
8710s
8716s
8740s
8750s
5950s
5903s10
5920s10 20A 230V
3A 230V
8703s10
8720s10
5906s10
5925s10
8706s10
8725s10
5910s10
5932s10
8710s10
8732s10
5916s10
5940s10
8716s10
8740s10
3A 230V 6A 230V
10A 230V 16A 230V
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² Short-circuit breaking capacity: 6KA BS EN 60898:2003
25A 230V 32A 230V 40A 230V
5945s10 45A 230V
5950s10 50A 230V
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003
6A 230V
10A 230V 16A 230V
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003
20A 230V 25A 230V 32A 230V 40A 230V
8750s10 50A 230V
8763s10 63A 230V
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003
MK Electric Catalogue
279
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
RCBOs With Solid Neutral Single Pole
Residential 6kA RCD Double Pole Type AC
TYPE B ONE MODULE
7932s
16 AMP TWO MODULE
TYPE C ONE MODULE
7933s
7934s
7935s
8932s
8933s
8934s
7816s
7936s
7937s
7932s1
6A 230V 30mA TRIPPING CURRENT
7933s1 10A 230V 30mA TRIPPING CURRENT
7934s1 16A 230V 30mA TRIPPING CURRENT
Suitable for installation in Sentry Consumer Units. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 119 x 18 x 73mm CABLE CAPACITY: Live 25mm², Neutral 25mm² SHORT CIRCUIT BREAKING CAPACITY: 6KA BS EN 61009-1 BS IEC 61009-2-2
280
mkelectric.co.uk
7938s
7939s
7935s1 20A 230V 30mA TRIPPING CURRENT
7936s1 32A 230V 30mA TRIPPING CURRENT
7937s1 40A 230V 30mA TRIPPING CURRENT
7938s1 45A 230V 30mA TRIPPING CURRENT
7939s1 50A 230V 30mA TRIPPING CURRENT
8935s
8936s
8932s1 6A 230V 30mA TRIPPING CURRENT
8933s1 10A 230V 30mA TRIPPING CURRENT
8934s1 16A 230V 30mA TRIPPING CURRENT
8935s1 20A 230V 30mA TRIPPING CURRENT
8936s1 32A 230V 30mA TRIPPING CURRENT
7816s1 16A 230V 30mA TRIPPING CURRENT
32 AMP TWO MODULE
7832s
7832s1 32A 230V 30mA TRIPPING CURRENT
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
40 AMP TWO MODULE
63 AMP TWO MODULE
80 AMP TWO MODULE
7860s
7880s
7660s
7680s
7860s1
7880s1
7560s1
7580s1
7840s
7840s1 40A 230V 30mA TRIPPING CURRENT
63A 230V 30mA TRIPPING CURRENT 63A 230V 100mA TRIPPING CURRENT
7660s1 63A 230V 300mA TRIPPING CURRENT
80A 230V 30mA TRIPPING CURRENT
80A 230V 100mA TRIPPING CURRENT
7680s1 80A 230V 300mA TRIPPING CURRENT
MK Electric Catalogue
281
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Industrial 10kA RCDs Double Pole Type AC 16 AMP TWO MODULE
32 AMP TWO MODULE
6016s
6032s
6316s
6730s
6016s1
6032s1
6416s1
6730s1
16A 110V 10mA TRIPPING CURRENT 16A 110V 30mA TRIPPING CURRENT
32A 110V 30mA TRIPPING CURRENT 32A 230V 30mA TRIPPING CURRENT
6316s1 16A 230V 10mA TRIPPING CURRENT
5716s1 16A 230V 30mA TRIPPING CURRENT
282
mkelectric.co.uk
40 AMP TWO MODULE
5740s
5740s1 40A 230V 30mA TRIPPING CURRENT
63 AMP TWO MODULE
80 AMP TWO MODULE
100 AMP TWO MODULE
5760s
6080s
6600s
5860s
5880s
7800s
5760s1
6080s1
7700s1
6160s1
5780s1
6600s1
5860s1
6180s1
7800s1
63A 230V 30mA TRIPPING CURRENT
63A 230V 100mA TRIPPING CURRENT 63A 230V 300mA TRIPPING CURRENT
80A 110V 30mA TRIPPING CURRENT 80A 230V 30mA TRIPPING CURRENT
80A 230V 100mA TRIPPING CURRENT
5880s1 80A 230V 300mA TRIPPING CURRENT
100A 230V 30mA TRIPPING CURRENT
100A 230V 100mA TRIPPING CURRENT 100A 230V 300mA TRIPPING CURRENT
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm² BS EN 61008:1995
Industrial 10kA RCDs Pulsating d.c. Fault Current Sensitive Double Pole Type A
Industrial 10kA RCDs Time Delayed Double Pole
TWO MODULE
TWO MODULE
6216s
5640s
6980s
6630s
6216s1 16A 230V 10mA TRIPPING CURRENT
6630s1 32A 230V 30mA TRIPPING CURRENT
5640s1 40A 230V 30mA TRIPPING CURRENT
5660s1 63A 230V 30mA TRIPPING CURRENT
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
Industrial 10kA RCDs Four Pole Type AC 25 AMP FOUR MODULE
6425s
80A 230V 100mA TRIPPING CURRENT TIME DELAYED
6400s1 100A 230V 100mA TRIPPING CURRENT TIME DELAYED
Suitable for installation in Sentry Consumer Units and Four Module enclosures. When used as a mains incomer these units will provide discrimination with downstream instantaneously operating 10mA or 30 mA RCD’s. For example, they can be used as main incomers on split load consumer units where it is not desirable, because of the possibility of unwanted tripping, to place all of the circuits on an instantaneous 30mA RCD, but where earth leakage protection is still required for these circuits or where compliance is required to the indirect contact protection requirements of the IET Wiring Regulations.
6440s
6240s
6400s
6980s1
40 AMP FOUR MODULE
6425s1
25A 230/400V 30mA TRIPPING CURRENT
Suitable for installation in Sentry four module enclosures and Commando Combi. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995
6440s1 40A 230/400V 30mA TRIPPING CURRENT
6240s1 40A 230/400V 100mA TRIPPING CURRENT
DIMS: 81 x 36 x 76mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 NOT TO BE USED FOR PERSONAL PROTECTION AGAINST ELECTRIC SHOCK
FACTORY BUILT SERVICE MK can save you time and money by pre-assembling consumer units with your required Sentry components
MK Electric Catalogue
283
CIRCUIT PROTECTION
Sentry Industrial 10kA RCDs Four Pole Type AC 63 AMP FOUR MODULE
6463s
mkelectric.co.uk
Industrial 10kA RCD Contactors Pulsating d.c. Fault Current Sensitive, Four Pole Type A FOUR MODULE
6640s
6363s
6463s1
63A 230/400V 30mA TRIPPING CURRENT
6363s1 63A 230/400V 100mA TRIPPING CURRENT
6263s1 63A 230/400V 300mA TRIPPING CURRENT
6640s1 40A 230/400V 30mA TRIPPING CURRENT
Suitable for installation in Sentry two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995
ONE MODULE
TWO MODULE
THREE MODULE
6220s
7240s
7440s
6720s
7263s
7463s
20A DOUBLE POLE
20A FOUR POLE
6420s1
7440s1
6720s1
7240s1
7463s1
6220s1
20A DOUBLE POLE WITH MANUAL OVERRIDE
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Automatically switches higher loads than possible with a time switch eg; off peak tariffs. A manual override enables the temporary setting of the contactor in either the on or off position in addition to normal automatic operation. When a contactor is mounted alongside an MCB of greater than 10 amp current rating or two contractors are mounted alongside an MCB or side by side, it is necessary to insert a blank module between them (list no.5544s)
40A DOUBLE POLE
40A FOUR POLE 63A FOUR POLE
7263s1 63A DOUBLE POLE
CONTACTOR RATINGS: List no
6220s 6420s 6720s
7240s 7440s
7263s 7463s
RATED CURRENT Ith
20A
40A
63A
5.4kW 16kW
8.6kW 26kW
13.6kW 41kW
1.1kW 4kW
2.2kW 7.5kW
4kW 11kW
2,800W 2,000W
7,000W 4,200W
10,000W 6,300W
VOLTAGE RATING (coil)
230V 50Hz
230V 50Hz
230V 50Hz
CABLE CAPACITY
6mm2 rigid
25mm2 rigid
25mm2 rigid
6220S: 84 x 18 x 66mm 7240S: 84 x 36 x 66mm 7463S: 84 x 54 x 66mm
6420S: 84 x 36 x 66mm 7263S: 84 x 36 x 66mm
6720S: 84 x 18 x 66mm 7440S: 84 x 54 x 66mm
HEATING
Single phase 230V Three phase 400V MOTORS Single phase 230V Three phase 400V LIGHTING
Incandescent and Halogen lamps: Fluorescent Lamps: (Electronic Ballast)
BS EN 61095 DIMENSIONS:
284
mkelectric.co.uk
(including half module blank)
Bell Transformer
TWO MODULE
5711s
CIRCUIT PROTECTION
Sentry
Technical Hotline +44 (0)1268 563720
Time Switches DIGITAL ONE CHANNEL TWO MODULE
DIGITAL ONE CHANNEL ONE MODULE
SYNCHRONOUS THREE MODULE
QUARTZ STABILISED THREE MODULE
SYNCHRONOUS ONE MODULE
5707s
5824s
5833s
5731s
5733s
5732s
5824s1
5833s1
5731s1
5733s1
5732s1
Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures. Power reserve 150 hours VOLTAGE RATING: 220-240Va.c. 50-60Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993
Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 90 x 18 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993
Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment, holiday programme and random generator are standard facilities. Power reserve of 150 hours. Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 90 x 18 x 74mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993
Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993
DIGITAL TWO CHANNEL TWO MODULE
5724s
5711s1 RATING 1A AT 8V PRIMARY 220 – 240V A.C.50HZ Suitable for installation in Sentry Consumer Units and two or four module enclosures. NOTE: When installed in a consumer unit, ensure that output cables inside the enclosures are suitable for a 230V environment, either by sleeving the bell wire to BS 2848 or using 230V cable. Complete with terminal covers. Also suitable for surface mounting. DIMENSIONS: 88 x 36 x 67mm CABLE CAPACITY: 1 x 2.5mm2 EN 61558-2-8
5707s1
7 DAY DIAL MIN SETTING 3 HOURS
5724s1 24 HOUR DIAL MIN SETTING 30 MINUTES
Suitable for DIN rail mounting in Sentry Consumer Units or four module enclosures. VOLTAGE RATING: 220-240Va.c. 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2
24 HOUR DIAL MIN SETTING 30 MINUTES
24 HOUR DIAL MIN SETTING 30 MINUTES
24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE
Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993
24 HOUR DIAL MIN SETTING 1 MINUTE
24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE
MK Electric Catalogue
285
CIRCUIT PROTECTION
Sentry Time Delay Switches
mkelectric.co.uk
Consumer Unit Cable Kits
Accessories
ONE MODULE
PUSH LEVER UP TO SWITCH ON RCBO
TEST BUTTON PUSH LEVER UP TO SWITCH ON
10
11
12
13
14
15
16
18
19
20
21
22
23
24
2
14
RCD PROTECTED CIRCUITS
RCD PROTECTED CIRCUITS
TEST QUARTERLY
TEST QUARTERLY
3
4
5
6
17
18
7
8
19
20
9
10
SWITCH
1
2
3
9 17
4
5
10
11
12
13
18
19
20
21
RCD PROTECTED CIRCUITS
1
2
14
(Cut as required)
12
13
22
23
24
15
U1
16
U2
SOCKETS GROUND FLOOR
SOCKETS FIRST FLOOR
K8041s
K5545sMAG
24
TEST QUARTERLY
4
5
6
17
18
7
8
19
20
9
10
21
LIGHTS OUTSIDE
RING CIRCUIT KITCHEN
RING CIRCUIT
SECURITY OUT ALARM BUILDING
220-250V 50Hz a.c.
220-250V 50Hz a.c.
SHOWER
SHOWER
SECURITY ALARM
RATED CURRENT MUST NOT EXCEED 63A MAX
RATED CURRENT MUST NOT EXCEED 100A MAX
SMOKE ALARM
CLEAN EARTH
DOOR BELL
4 module unit
CENTRAL HEATING
FRIDGE
COOKER
COMPUTER
SMOKE ALARM
LIGHTS
KITCHEN SOCKETS
LIGHTS
GARAGE SOCKETS
GARAGE LIGHTS
ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY
DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER
OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3
12
13
22
23
24
15
U1
16
U2
U3
H Main Switches Warning Labels
ON
IMPORTANT
SOCKETS
LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR
RING CIRCUIT FIRST FLOOR
WATER HEATER
SOCKETS
WARNING
SOCKETS SECOND FLOOR
LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR
WATER HEATER
(Cut as required)
11
ON
STORAGE STORAGE HEATER HEATER
LIGHTS BASEMENT RING CIRCUIT BASEMENT
FREEZER
LIGHTS FIRST FLOOR
21
H Main Switches Warning Labels
OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3
WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER
SOCKETS BASEMENT
SOCKETS GROUND FLOOR
SOCKETS FIRST FLOOR
LIGHTS OUTSIDE
RING CIRCUIT KITCHEN
RING CIRCUIT
SECURITY OUT ALARM BUILDING
220-250V 50Hz a.c.
220-250V 50Hz a.c.
SHOWER
SHOWER
SECURITY ALARM
RATED CURRENT MUST NOT EXCEED 63A MAX
RATED CURRENT MUST NOT EXCEED 100A MAX
SMOKE ALARM
CLEAN EARTH
DOOR BELL
4 module unit
CENTRAL HEATING
FRIDGE
COOKER
COMPUTER
SMOKE ALARM
K5597s
LIGHTS
KITCHEN SOCKETS
LIGHTS
GARAGE SOCKETS
IMPORTANT
SOCKETS
LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR
RING CIRCUIT FIRST FLOOR
WATER HEATER
SOCKETS
WARNING
SOCKETS SECOND FLOOR
LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR
WATER HEATER
LIGHTS FIRST FLOOR
ON
STORAGE STORAGE HEATER HEATER
LIGHTS BASEMENT RING CIRCUIT BASEMENT
FREEZER
8, 12, 16 & 21 module units
This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.
5650s
8 16
23
RCD PROTECTED CIRCUITS
3
G Individual Circuit Labels
5544s
7 15
22
TEST QUARTERLY
F Circuit ID Labels
U3
RCD TIME DELAYED
11
ON
5562s
6 14
RCD PROTECTED CIRCUITS
TEST QUARTERLY
MAIN
SWITCH
F Circuit ID Labels
SOCKETS BASEMENT
B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RCD TIME DELAYED
1
RCBO
TEST BUTTON
RCD
ADDITIONAL INFORMATION
8
TEST QUARTERLY
PUSH LEVER UP TO SWITCH ON
PUSH LEVER UP TO SWITCH ON
Pantone 355
CIRCUIT NUMBER
7
RCD PROTECTED CIRCUITS
Pantone Black
E Additional Information Label
6
A RESETTING INSTRUCTION LABEL
ADDITIONAL INFORMATION
5
CIRCUIT NUMBER
4
MAIN
Mid-Trip Off
Pantone 102
Pantone Blue??
If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720.
3
E Additional Information Label
9 17
TEST BUTTON
On
MCB
RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected.
Pantone 485
This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice.
RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on".
B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit.
RCD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 2
MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320
SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer
If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720.
A RESETTING INSTRUCTION LABEL
1
Ref: Ono: Our Ref: Date: Version: Size:
WARNING
Pantone 355
GARAGE LIGHTS
DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER
ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY
OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3
OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3
WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER
8, 12, 16 & 21 module units
G Individual Circuit Labels
This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.
K5599s
K5563s
K6061SMET
K5511s
5650s1
DELAY RANGE 1 - 7 MINUTES (APPROX)
Suitable for installation in Sentry Consumer Units and two or four module enclosures. Offers time delay control for complete circuits of either tungsten or fluorescent lighting with any number of standard push switches. It can also be used to control fans in bathrooms without a window. Delay setting can be over-ridden by setting to ‘Perm-on’ mode, or by fitting a remote overriding switch. Switch has a switching capacity of 16A Resistive loads (upf) Fluorescent lamps uncompensated Series compensated 1300W Parallel compensated 480W CFLS 100W Max. Maximum of 9 units can be connected Incandescent lamps 2000W Neon glow lamp load (locating lamp for Push Switch) 50mA max VOLTAGE RATING: 230V 50Hz DIMENSIONS: 84 x 18 x 70mm CABLE CAPACITY: 1 x 4mm2or 2 x 1.5mm2
286
mkelectric.co.uk
K5565s
K5593s
KAX26s
K6062SMET
K5563s5
5562s1
5544s5
K5597s5
SPLIT-LOAD KIT CONSISTS OF 3 CABLES (2 NEUTRAL AND 1 LIVE) FOR USE WHEN ASSEMBLING A SPLIT LOAD ARRANGEMENT
K5565s5 MULTI-INCOMER KIT CONSISTS OF A BLUE FLEXIBLE CABLE WITH PRE-FITTED TERMINAL FOR THE NEUTRAL RETURN FROM SWITCH OR RCD TO SECOND OR THIRD NEUTRAL BAR
K5568s5 17TH EDITION CABLE KIT FOR SWITCH AND TWIN RCD ARRANGEMENT
K5567s5 A&D CABLE KIT FOR SWITCH PLUS TRIPLE RCD ARRANGEMENT
K5563S For use when assembling split-load arrangement. K5565S For use when assembling a consumer unit in a multi-incomer arrangement with separate supply to each incomer. These kits must be used to ensure compliance with BS EN 60439-3
EXTENSION TERMINAL FOR USE WHEN ASSEMBLING A CONSUMER UNIT AS A DISTRIBUTION BOARD. ENABLES DIRECT CONNECTION OF CABLES TO THE NEUTRAL BAR. CONSISTS OF A 25MM2 CAPACITY TERMINAL WITH CLAMP SCREW
K8041s10 LOCKING DEVICE FOR USE WHEN LOCKING A SENTRY MCB, RCBO, RCD OR SWITCH DISCONNECTOR IN EITHER THE ON OR OFF POSITION
K5593s
BARREL LOCK AND KEY KIT SUITABLE FOR SECURING ‘K’ SERIES SENTRY CONSUMER UNIT LIDS. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS
1
MCB BLANK – GREY DESIGNED TO FILL UNUSED MODULES IN SENTRY CONSUMER UNITS AND SMALL ENCLOSURES. DIN-RAIL MOUNTED
K5545sMAG10 COVER MOUNTED BLANK FOR FILLING SPACES IN THE ‘K’ SERIES SENTRY CONSUMER UNIT COVER, WHERE THERE ARE UNUSED MODULES
K5511s1 BUSBAR 11 MODULE
K5590s1 BUSBAR 20 MODULE
KAX26s10 BUSBAR COVER SUITABLE FOR INSULATING THE BUSBARS K5511S AND K5590S 20 MODULE. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS
ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER
Mid-Trip Off
Pantone Black
C Busbar Shield Warning Label (Factory fitted)
TEST BUTTON
On
MCB
RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected.
Pantone 102
Pantone Blue??
WARNING
RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on".
Pantone 485
This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice.
ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER
MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320
SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer
C Busbar Shield Warning Label (Factory fitted)
Ref: Ono: Our Ref: Date: Version: Size:
CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON DUAL & TRIPLE RCD BOARDS
K5599s5 CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON SINGLE RCD BOARDS
K5804sD1MAG K5808sD1MAG K5812sD1MAG K5816sD1MAG K5821sD1MAG
REPLACEMENT PLASTIC FRONT COVERS
K6060SMET1 16 WAY METAL CONSUMER UNIT SURFACE MOUNTING KIT
K6061SMET1 12 WAY METAL CONSUMER UNIT STACKING KIT
K6062SMET1 16 WAY METAL CONSUMER UNIT STACKING KIT
ASPECT DOUBLE SOCKET – BESPOKE FINISH
Available on a worldwide basis, the MK Design Service is supported by a dedicated team to ensure the seamless delivery of your chosen products. To find out more visit www.mkelectric.co.uk
MK Electric Catalogue
287