Seminars. Literature. Further information on this subject can be requested from WTW:

BSB BOD DBO BOD BOD measurements according to DIN Measurement BOD measurement according to EN 1899-1 and EN 1899-2 and for self-checks Biological ...
Author: Phyllis Benson
0 downloads 0 Views 1MB Size
BSB

BOD

DBO

BOD BOD measurements according to DIN Measurement BOD measurement according to EN 1899-1 and EN 1899-2 and for self-checks

Biological Oxygen Demand The Biological Oxygen Demand is an important parameter in water resource management. It is a quantity used for the quality of water and the purification power of biological wastewater treatment stages. In addition it is essential in the planning and dimensioning of sewage treatment plants. In routine use BOD determination is used to check the wastewater in the inflow and discharge of sewage treatment plants. Depending on the measurement site and type of wastewater the BOD value can lie between a few mg/l and several thousand mg/l. Several methods are available for carrying out the measurement. WTW offers various measuring systems for these methods. In “dilution BOD” the oxygen content of a sample is measured with an oxygen sensor before and after an incubation period of 5 days. The difference between the measurements is the BOD5 value; this method is officially recognized. In “BOD self-checks” with the respirometer the reduction in oxygen causes a definite pressure difference which can be measured by a pressure sensor. This method is very easy to carry out and is a practical method. As these two methods are basically very different they only correlate for a few samples which, however, have a practical relevance such as in the discharge channels of municipal sewage treatment plants. In both cases the samples must be kept at 20 °C for 5 days. WTW offers a wide range of suitable thermostatted equipment.

Seminars WTW offers seminars in which the subject of BOD measurement is treated in detail. On request WTW will be pleased to send you further details about these seminars.

Literature Further information on this subject can be requested from WTW:

BOD primer (CD-ROM) Application reports Offprints

108 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Laboratory & Field General Features

BOD Measurement

pH

“Dilution BOD”

ORP

according to EN 1899-1 (previously DIN 38 409 P51) and EN 1899-2 from page

inoLab® BSB/BOD Level 3 Versatile, accurate, with evaluation program 110 acc. to EN 1899-1, EN 1899-2 and ISO 5815-1989 Comfortable, robust, accurate

113

OxiTop® IS 12

OxiTop®

Simple handling, 5-day memory, mercury-free pressure measurement

114

OxiTop® Control

Comfortable, large memory, infrared data transmission, graphics display

118

Extension sets and Accessories

❍ OxiTop® measuring heads + SETs ❍ OxiTop® control system

123 123

(measuring heads, controller...) 124 125 125

❍ Thermostat boxes ❍ Thermostat cabinets

126 127

Photometry

Thermostats

❍ Stirrer platforms ❍ Storage racks, marking rings ❍ General accessories

Applications from page

For documentation

For applications for soil analysis, biodegradability and others please refer to the Oxygen consumption rate section

130

Software, printers and accessories

180

Customer Service

OxiTop® Control

BOD

from page

Turbidity

Model

Respiration Sample Preparation

practical method according to the self-check regulations (previously DIN 38 409 P51)

Colony Counter

“BOD self-check measurement”

MultiParameter

Conductivity

Oxygen (D.O.)

ProfiLine Oxi 197, ProfiLine Oxi 197-S

Software, Printers

inoLab® BSB/BOD Level 3

ISE

with instrument

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

109

BSB

BOD

DBO

EN 1899-1/ 1899-2

“Dilution BOD”

according to EN 1899-1 (previously DIN 38 409 P51) and EN 1899-2

BOD5 measurements can be carried out with all WTW laboratory oxygen meters. The instruments as the complete range of accessories are described in the “oxygen meters” section.

With inoLab® BSB/BOD Level 3 flexible and powerful inoLab® BSB/BOD Level 3 with terminal, self-stirring StirrOx® G oxygen sensor and bar-code reader

NEW

110

IP 43

3 Year Warranty

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

StirrOx® G

Laboratory & Field ORP ISE BOD

MultiParameter

Self-stirring oxygen sensor – simultaneous stirring and measurement

Colony Counter

Optionally a PC keyboard or bar-code reader can be connected for sample identification

• For a detailed description of further oxygen meters in the inoLab® family • Complete range of accessories

see page 66 ff. see page 70 ff.

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Customer Service

Software, Printers

Turbidity

Photometry

● Single-handed operation for rapid series measurements ● Constant approach flow for high reproducibility ● Immediately ready for measuring – no polarization period required ● Extremely low self-consumption of oxygen - only 0.008 µg h-1 (mg/l)-1 ● Zero-current free – no zero point calibration necessary ● With calibration and storage vessel OxiCal®-ST as standard ● Long working life – 6 months with one electrolyte filling ● IMT temperature compensation with 2 built-in temperature sensors ● Membrane leakage monitoring – damaged membranes are indicated

Oxygen (D.O.)

• BOD/depletion • Determination of the biochemical oxygen demand according to DIN EN 1899-1 • Determination of oxygen depletion according to DIN 38 414 P6 • Up to 5 samples for dilution water • Up to 30 measuring samples • Up to 18 dilutions per measuring sample • Up to 7 routines can be stored • Adjustable incubation time, 5 ... 30 days

Conductivity

This laboratory oxygen meter has been specially developed for BODn measurements. A special program allows BODn determination according to EN 1899-1. You can store up to 7 of your own routines for frequently occurring dilution ratios. A maximum of 30 measuring samples each with 18 dilutions allow the management of up to 540 diluted samples. The inoLab® BSB/BOD Level 3 can also be used as a conventional high-end oxygen meter.

Special functions

Respiration Sample Preparation

Versatile – precise – with BODn evaluation program

pH

General Features

“Dilution BOD” according to EN 1899-1 (previously DIN 38 409 P51) and EN 1899-2

111

BSB

BOD

DBO

Technical Data inoLab® BSB/BOD Level 3 Measuring range/ Resolution

O2 conc.

Temperature

0.00 ... 19.99 mg/l 0.0 ... 90.0 mg/l* 0.0 ... 199.9% 0 ... 600%* 0.0 ... 199.9 mbar 0 ... 1250 mbar -5.0 ... +50.0 °C

Accuracy (±1 digit)

O2 conc. O2 saturation Temperature

±0.5% of value ±0.5% of value ±0.1 K

Temp. compensation

0 ... +50 °C automatic via IMT compensation

Salinity correction

Automatic from 0.0 ... 70.0, adjustable via display

O2 saturation O2 part. press.

* depends on oxygen sensor and medium

AutoRead

For reproducibility better than 0.05 mg/l or better than 1 mbar pO2

Real-time clock

Not affected by power cuts

KCalibration

OxiCal® rapid calibration in OxiCal®-SL

Data memory

2000 Data sets (measurement, temperature, time/date, ident no.); time-controlled storage at intervals from 1 s ... 60 days, data storage period unlimited BSB/BOD: max. 540 diluted samples and multiple dilution water

Data output

Via display or interface

Interface

Self-configuring as analog output 0-2 V or bidirectional RS 232

Other connections

For StirrOx® G with automatic AutoRead start and stop via key on StirrOx® G

Operating time

Continuous from mains supply

Protection type

IEC 529 / IP 43

Dimensions (B x D x H in mm)

300 x 250 x 70

Weight

Approx. 1.5 kg

Certified to

CE, TÜV/GS, UL, CUL

Warranty

3 years on the instrument

Ordering Information BOD measurement with inoLab® BSB/BOD Level 3

Order No.

inoLab® BSB/BOD Level 3 Flexible and powerful – the intelligent BOD measuring place consisting of multifunction box and universal terminal, with PC software/connection cable

1H30-010

inoLab® BSB/BOD Level 3 Intelligent BOD measuring place with additional built-in printer

1H31-010

inoLab® BSB/BOD Level 3 The integrated BOD measuring place, with PC software/connection cable, without printer/terminal

1H32-000

KF 12

Karlsruhe bottle including 60 mm ground stopper, suitable for BOD5 determination, minimum order 10 bottles

205 700

Ordering Information SETs inoLab® BSB SETs

Order No.

inoLab® BSB/BOD Level 3 Including terminal, oxygen sensor and accessories

1H30-011

inoLab® BSB/BOD Level 3 With built-in printer, including terminal, oxygen sensor and accessories

1H31-011

inoLab® BSB/BOD Level 3 Without printer/terminal, with PC software/connection cable, sensor and accessories

1H32-001

Accessories CellOx® 325-3 StirrOx G

Galvanic oxygen sensor, 3 m cable Self-stirring oxygen sensor

2 4

Bar-code reader SET ordering example

2

inoLab® BSB/BOD Level 3 + CellOx® 325-3

1H30-011

2

Note: other sensors in SET and instruments versions for 120 VAC/60 Hzs are available on request

112

Please refer to page 70 for oxygen sensors and page 74 for further accessories. Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Laboratory & Field General Features

“Dilution BOD” according to EN 1899-1 (previously DIN 38 409 P51) and EN 1899-2

pH

With ProfiLine Oxi 197, Oxi 197-S

ORP

comfortable · robust · accurate

Ordering Information BOD measurement with ProfiLine Oxi 197 and Oxi 197-S

Order No.

ProfiLine Oxi 197

ProfiLine oxygen meter, extremely robust, hose-water proof (IP 66), RS 232 digital output, operation from mains supply or rechargeable batteries, with plug-in power supply with connection for self-stirring oxygen sensor StirrOx® G and CellOx® 325

200 350

ProfiLine Oxi 197-S

As ProfiLine Oxi 197, but additionally with 2 analog recorder outputs corresponding to the display of oxygen and temperature

200 313

StirrOx® G

Self-stirring oxygen sensor for oxygen determination in Karlsruhe bottles, with OxiCal®-ST calibration and storage vessel and accessory case with spare parts and maintenance supplies

201 425

KF 12

Karlsruhe bottle including 60 mm ground stopper, suitable for BOD5 determination, minimum order 10 bottles

205 700

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Colony Counter Turbidity

Photometry

see page 64 ff. see page 70 ff.

Software, Printers

• Detailed description of the ProfiLine Oxi 197 and Oxi 197-S laboratory oxygen meters • Complete range of accessories

3 Year Warranty

Customer Service

IP 66 IP 67

Respiration Sample Preparation

BOD

MultiParameter

Conductivity

Oxygen (D.O.)

ISE

Laboratory oxygen meters ProfiLine Oxi 197 and ProfiLine Oxi 197-S with self-stirring oxygen sensor StirrOx® G

113

BSB

BOD

DBO

BOD “BOD Self-Check Measurement Measurements” Practical method according to the self-check regulations Proposal for a German standard method – DEV 46th installment 2000 – H55 OxiTop® IS 6, OxiTop® IS 12

U.S. patent granted (US 5,770,153)

1 Year Warranty Mercury-free BOD measurement

Features Simple handling Mercury-free measurement 5-day memory Push-button measurements possible Extendable Mobile Precise

Despite all discussions about quicker alternative methods, the determination of the biological oxygen demand BOD has not become any less important. On the contrary, it is still one of the most important measurements for the management of water resources and allows statements to be made about the loading of waters and wastewater with biodegradable substances. The importance of the respirometric BOD measurement is also shown by the inclusion of the “Determination of the biochemical oxygen demand after n-days (BODn) in a respirometer – extension of the method according to DIN EN 1899-2 (H55)” as a proposal for a German standard method in the 46th installment 2000 of the DEV.

Criticisms of the conventional manometric measuring systems have mainly concerned the use of mercury for measuring the pressure. Mercury is toxic and if not handled properly it produces vapors which are injurious to health. With the development of the OxiTop® systems, WTW has fulfilled a worldwide customer wish – mercury-free BOD determinations. With OxiTop® WTW now offers a unique and modular mercury-free BOD instrument system which has been developed for daily practical use. OxiTop® alters the previous handling process in a revolutionary manner.

114 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

General Features

OxiTop® IS 6, IS 12

Laboratory & Field

“BOD self-check measurements”

pH

Complete package for 6 or 12 measuring places

ORP

The OxiTop® IS 6, IS 12-6 and IS 12 complete packages have been assembled so that they contain everything necessary to carry out the measurements.

ISE

OxiTop® IS 6

Oxygen (D.O.)

Ready for use with 6 measuring places

OxiTop® IS 12-6

Conductivity

Ready for use with 6 measuring places, extendable to 12 places

MultiParameter

OxiTop® IS 12 Ready for use with 12 measuring places

Conversion to OxiTop® Any conventional manometric BOD measuring instrument (no matter whether from WTW or anybody else) can be converted to the OxiTop® system. Various conversion sets are available. (see page 123)

Customer Service

Test agents see page 125

Respiration Sample Preparation

... or conversion

Colony Counter

1 Stirrer platform IS 6/IS 12 with plug-in mains power supply (see page 124) 1 REF 600 Stirrer bar remover 1 NHP 600 NaOH pellets 1 NTH 600 Nitrification inhibitor 1 MK 164/600 Overflow flask 164 ml 1 MK 432/600 Overflow flask 432 ml 1 Dia/600 Chart paper block

Photometry

Each package contains:

1 Year Warranty

Turbidity

OxiTop® (green or yellow) PF 600 Amber sample bottle GK 600L Rubber sleeve RST 600 Stirrer bar

Software, Printers

1 1 1 1

BOD

Each measuring place contains the following items:

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

115

BSB

BOD

DBO

¡ OxiTop® closely observed BOD measurement with “brains” US patent granted (US 5,770,153) Registered industrial property rights: • Protected design patent • Utility model patent

The patented measuring head contains the following items: ● 1 Piezoelectric pressure sensor ● 2 Operating keys: M for showing the momentary value; S for showing the stored value ● 2-place LED, displaying 00 to 50 “scale divisions”. 1 scale division corresponds to 3.55 hPa. A correct measurement should only show scale divisions up to 40; with larger values the sensible measuring range has already been exceeded so that the display only serves for orientation purposes. ● Data memory for 5 measurements at daily intervals. It is not necessary to read off the measurements every day as they are made automatically. This means that measurements can be carried out over a weekend with unattended operation. The measurement can also be read off after 7 days (BOD7). ● AutoTemp function: delayed start of measurement for samples which are too cold. OxiTop® delays the start until a constant temperature has been achieved; the minimum delay period is 1 hour. ● 2 batteries with a typical working life of 1 year (if properly used for BOD measurements).

Very modern microelectronics Pressure sensor, microcontroller, timer, memory

IP 54

1 Year Warranty

Technical Data OxiTop®-measuring head Measuring principle

Manometric with pressure sensor

Quantity measured

BODn

Measuring range

0 ... 40 digits (display units) equals 0 ... 40 / 80 / 200 / 400 / 800 / 2000 / 4000 mg/L BOD

Display range

0 ... 50 digits

Display accuracy

±1 digit (^ = ±3.55 hPa)

Display

2-character 7-segment LED, 10 mm

Operating range

500 ... 1100 hPa

Memory

For BOD, daily

Power supply

Lithium battery (280 mAh) 2 x CR 2430

Power consumption

Max. 25 mA (during display of measurements)

Safety class

3 to IEC 1010

Protection type

IP 54 to DIN 40 050

EMC

EN 61326 Class B, FCC Class A

Climate class

2, VDI/VDE 3540

Ambient temperature

Storage: -25 ... +65 °C Operation: +5 ... +50 °C

Dimensions

69 x 70 mm (H x dia.)

Test certificates

CE, TÜV/GS, UL, CUL

Warranty

1 year on the instrument

116 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Laboratory & Field General Features

“BOD self-check measurements”

pH

Ordering Information Order No.

Complete package, ready for use, for 6 measuring places, with IS 6 Inductive Stirring System, for mains operation 230 V / 50/60 Hz and 6 OxiTop® measuring systems, including 6 sample bottles, 6 rubber sleeves, 6 stirrer bars and other accessories

208 210

OxiTop® IS 12-6

Complete package, ready for use, for 6 measuring places (extendable to 12 measuring places), with IS 12 Inductive Stirring System, for mains operation 230 V / 50/60 Hz and 6 OxiTop® measuring systems, including 6 sample bottles, 6 rubber sleeves, 6 stirrer bars and other accessories

208 212

OxiTop® IS 12

Complete package, ready for use, for 12 measuring places, with IS 12 Inductive Stirring System, for mains operation 230 V / 50/60 Hz and 12 OxiTop® measuring systems, including 12 sample bottles, 12 rubber sleeves, 12 stirrer bars and other accessories

208 211

ORP

OxiTop® IS 6

OxiTop® IS 6

Accessories

from page

OxiTop® IS 6 and OxiTop® IS 12

System extensions Conversions (OxiTop® measuring heads, stirring systems IS 6, IS 12) Storage rack for OxiTop® Marking rings

123 123 125 125

Thermostatic instruments (boxes, cabinets)

126 Customer Service

For system

Software, Printers

Accessories

Turbidity

Photometry

Colony Counter

OxiTop® IS 12

Respiration Sample Preparation

BOD

MultiParameter

Conductivity

Oxygen (D.O.)

Note: versions for 120 VAC / 60 Hz on request

ISE

BOD determination with OxiTop® “mercury-free” measuring system

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

117

BSB

BOD

DBO

BOD “BOD Self-Check Measurement Measurements” Practical method according to the self-check regulations Proposal for a German standard method – DEV 46th installment 2000 – H55 OxiTop® Control 6, OxiTop® Control 12

1 Year Warranty

Features Comfortable handling Mercury-free pressure measurement Large data memory in measuring head Infrared data transmission to controller Automatic sample management Automatic measuring protocol Mobile Precise

118

Comfortable BOD determination with the OxiTop® Control system The OxiTop® Control system is the logical further development of the successful OxiTop® system. • Instead of the display and keys the OxiTop®-C measuring head has an infrared interface with which it communicates with Controller OC 100 or OC 110. • The Controller OC 100/OC 110 can manage up to 100 OxiTop®-C measuring heads.

The measuring head stores 180 to 360 data sets (depending on set running time) which can be called up at any time in the Controller and where they are shown graphically. Call-up is by collect call or selectively by “pointing” to the required measuring head. Each measuring head has its own identification; this means that manual identification is no longer necessary.

• Documentation is carried out via the Achat OC program in combination with a PC (or the TD 100 Thermal printer)

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

General Features

Operation

• Set running time

• Wait until set running time has elapsed • If necessary, monitor sample by calling up the data (can also be carried out through glass or Plexiglas,

• When measurement is finished result can be read off from the Controller display • Documentation of results

Conductivity

OxiTop® Control

ORP

• Data can be called up as often as required during the measurement

ISE

• Incubate sample

so that the sample is not disturbed by opening the door of the thermostat cabinet!)

Oxygen (D.O.)

• Set operating mode either BOD routine for single samples or BOD standard for samples with parallel batches and statistical evaluation

• Prepare sample and start measurement by briefly clicking the measuring head with the Controller

pH

Operation of the system is clear and simple • Select language

Laboratory & Field

“BOD self-check measurements”

Complete package for 6 or 12 measuring places

MultiParameter

The OxiTop® Control 6 and Control 12 complete packages have been assembled so that they contain everything necessary to carry out the measurements.

BOD

OxiTop® Control 6

Respiration Sample Preparation

Ready for use with 6 measuring places

OxiTop® Control 12 Ready for use with 12 measuring places

Each measuring place contains the following items:

Photometry

Colony Counter

OxiTop®-C PF 600 Amber sample bottle GK 600L Rubber sleeve RST 600 Stirrer bar

Software, Printers

1 Controller OC 100 1 Stirrer platform IS 6/IS 12 with plug-in mains power supply (see page 124) 1 REF 600 Stirrer bar remover 1 NHP 600 NaOH-pellets 1 NTH 600 Nitrification inhibitor 1 MK 164/600 Overflow flask 164 ml 1 MK 432/600 Overflow flask 432 ml 1 Dia/600 Chart paper block

Turbidity

Each package contains:

1 Year Warranty

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Customer Service

1 1 1 1

119

BSB

BOD

DBO

¡ OxiTop®-C closely observed BOD measurement with “infrared brains”

The measuring head with its protected design and utility model patents contains the following items: ● 1 Piezoelectric pressure sensor, pressure range 500 to 1350 hPa ● Infrared interface for data transmission to Controller with pilot lamp ● Data memory for max. 360 data sets. Data is stored automatically at preset time intervals from 0.5 hours to max. 99 days. ● AutoTemp function: delayed start of measurement for samples which are too cold. OxiTop®-C delays the start until a constant temperature has been achieved; the minimum delay period is 1 hour. In the BOD standard operating mode this function can be switched off. ● 2 batteries with a typical working life of 1 year.

1

IP 54

1 Year Warranty

Technical Data OxiTop®-C measuring head Measuring principle

Manometric with pressure sensor

Measurement of

BODn

Pressure range

500 ... 1350 hPa

Accuracy

± 1% of value ± 1 hPa

Resolution

1 hPa (corresponds to 0.7% of BODn measuring range)

Display

LED pilot lamp

Power supply

2 x CR 2430 lithium batteries (280 mAh)

Safety class

3, IEC 1010

Protection type

IP 54 to DIN 40 050

EMC

EN 61326 Class B, FCC Class A

Climate class

2, VDI/VDE 3540

Ambient temperature

Storage: -25 ... +65 °C Operation: +5 ... +50 °C

Dimensions

70 x 70 mm (H x dia.)

Test certificates

CE, TÜV/GS, UL, CUL

Warranty

1 year on the instrument

2

120

1

Short click from controller to measuring head to start the sample

2

Infrared call-up of data at incubator. Data transfer even through closed incubator doors and OxiTop® boxes

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

General Features

¡ OxiTop® Control closely observed

Laboratory & Field

“BOD self-check measurements”

pH

The handy Controller manages the data for up to 100 OxiTop®-C measuring heads.

ISE

OC 110 only:

Conductivity

Oxygen (D.O.)

OC 100/OC 110: 0 ... 40 / 80 / 200 / 400 / 800 / 2000 / 4000 mg/L BOD (corresponds to 0 ... 142 hPa) • measuring range variable with upper limit 400 000 mg/L (in BOD special mode) • 500 ... 1350 hPa (pressure mode)

Data sets per measurement

180 ... 360 (depends on running time)

Measurement period

Adjustable from: 0.5 ... 6 h in 0.5 h steps 6 ... 24 h in 1 h steps 1 .. 99 days in 1 day steps

Display

LCD graphics display 64 x 128 point

Energy supply

3 x 1.5 V alkaline batteries (AA/mignon)

Safety class

3, IEC 1010

Protection type

IP 42 to DIN 40 050

EMC

EN 61326 Class B, FCC Class A

Climate class

2, VDI/VDE 3540

Ambient temperature

Storage: -25 ... +65 °C Operation: +5 ... +40 °C

Dimensions

45 x 100 x 200 mm (H x B x D)

Weight

Approx. 390 g

Test certificates

CE, TÜV/GS, UL, CUL

Warranty

1 year on the instrument

Achat OC PC communication program, TD 100 thermal printer Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Respiration Sample Preparation

Measuring ranges

Colony Counter

● AutoTest with function monitoring and system messages ● High data security, independent of power supply from batteries

Controller OxiTop® OC 100 + OC 110

Photometry

Confidence in the measurements is guaranteed by:

Technical Data

Turbidity

● Large graphics display ● Operator guidance in - German, English, French, Spanish, Italian (OC 100) - German and English (OC 110) ● Data transmission even through glass doors ● Simple adaptation to specific measuring tasks

Software, Printers

Operating comfort guaranteed by:

BOD

MultiParameter

1 Year Warranty

IP 54

Customer Service

● Identifying the samples with automatic number allocation, i.e. manual marking or labeling the samples is not necessary ● Data call-up function for all samples or selected samples. ● Sample progress display ● Calculation, evaluation and graphical presentation of BOD value ● Protocol of data on batteryoperated TD 100 Printer or with a PC via the Achat OC communication program

ORP

This comprises:

121

BSB

BOD

DBO

Ordering Information BOD determination with Controller OxiTop® OC 100 and OxiTop®-C measuring heads “mercury-free” OxiTop® Control 6

Order No.

Complete package, ready for use, for 6 measuring places, with Controller OC 100 and IS 6 Inductive Stirring System, 208 201 for mains operation 230 V / 50/60 Hz and 6 OxiTop®-C measuring systems, including 6 sample bottles, 6 rubber sleeves, 6 stirrer bars and other accessories

OxiTop® Control 12 Complete package, ready for use, for 12 measuring places, with Controller OC 100 and IS 12 Inductive Stirring System, for mains operation 230 V / 50/60 Hz and 12 OxiTop®-C measuring systems, including 12 sample bottles, 12 rubber sleeves, 12 stirrer bars and other accessories

208 204

Note: versions for 120 VAC / 60 Hz on request

Accessories

Order No.

TD 100

Thermal printer (battery-operated) with IR interface for data transmission from Controllers OxiTop® OC 100 and OC 110 including 1 roll of special paper and 1 set of batteries

208 900

RP 100

1 roll of special paper for TD 100 thermal printer (minimum order 5 rolls)

208 910

Software

(see also page 180)

Order No.

ACHAT OC

PC communication program “ACHAT OC” for Controller OxiTop® OC 100 or OC 110 for further data processing and documentation of measuring data. Software requirements: Windows 3.1 or higher, update possibilities on request. Required accessory: interface cable AK 540/B

208 990

AK 540/B

Interface cable for connecting Controller to a PC via the RS 232 interface, including 9/25-pole adapter

902 842

Test agents see page 125

Accessories for system

Accessories

OxiTop® Control 6 System extensions OxiTop®-C IS 6, IS 12 and Storage rack for OxiTop® OxiTop® Control 12 Thermostatic instruments (boxes, cabinets)

from page 123 125 126

122 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Laboratory & Field

“BOD self-check measurements”

General Features

BOD System Extensions, Measurement Conversions,

ORP

pH

general accessories

ISE

System extensions and conversions

2 OxiTop® measuring heads (1 yellow, 1 green)

208 814

OxiTop®/GB

1 OxiTop® measuring head (yellow)

208 810

OxiTop®/GN

1 OxiTop® measuring head (green)

208 800

OxiTop® measuring heads in SETs with accessories

Order No.

OxiTop® SET-2

SET for 2 measuring units, complete with 2 OxiTop® measuring heads (1 yellow, 1 green), 2 sample bottles, 2 sleeves, 2 magnetic stirrer bars

208 819

OxiTop® SET-6

SET for 6 measuring units, complete with 6 OxiTop® measuring heads (3 yellow, 3 green), 6 sample bottles, 6 sleeves, 6 magnetic stirrer bars

208 817

OxiTop® SET-10

SET for 10 measuring units, complete with 10 OxiTop® measuring heads (5 yellow, 5 green), 10 sample bottles, 10 sleeves, 10 magnetic stirrer bars

208 818

OxiTop®-C measuring heads and SETs OxiTop®-C IS 6 / IS 12 extension sets for OxiTop® Control With the extension sets OxiTop®-C IS 6 and OxiTop®-C IS 12 the OxiTop® Control instruments can be extended by 6 and 12 measuring units respectively.

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

BOD

208 812

OxiTop®-2

Respiration Sample Preparation

6 OxiTop® measuring heads (3 yellow, 3 green)

Colony Counter

208 813

OxiTop®-6

Photometry

10 OxiTop® measuring heads (5 yellow, 5 green)

Turbidity

Order No.

OxiTop®-10

Software, Printers

OxiTop® measuring heads

Customer Service

Ordering Information OxiTop®-measuring heads and SETs

MultiParameter

Conductivity

The OxiTop® measuring systems can be used to convert all conventional BOD measuring systems in a very simple way.

Oxygen (D.O.)

OxiTop®-measuring heads and SETs

123

BSB

BOD

DBO

Ordering Information OxiTop®-C measuring heads and SETs OxiTop®-C measuring heads

Order No.

OxiTop®-C

1 OxiTop®-C measuring head

208 830

OxiTop®-C 2

2 OxiTop®-C measuring heads

208 823

OxiTop®-C 6

6 OxiTop®-C measuring heads

208 822

OxiTop®-C measuring heads in extension set for OxiTop® Control

Order No.

OxiTop®-C IS 6

Extension set for 6 measuring positions complete with IS 6 inductive stirring system, for mains operation 230 VAC 50/60 Hz, with 6 OxiTop®-C measuring heads and 6 sample bottles, 6 rubber sleeves, 6 magnetic stirrer bars

208 130

OxiTop®-C IS 12

Extension set for 12 measuring positions complete with IS 12 inductive stirring system, for mains operation 230 VAC 50/60 Hz, with 12 OxiTop®-C measuring heads and 12 sample bottles, 12 rubber sleeves, 12 magnetic stirrer bars

208 133

Note: versions for 120 VAC 60 Hz on request

Stirrers for BOD measurement Technical Data IS 6

IS 12

Energy supply

Plug-in mains transformer 230 VAC (+10%...-15%), 50/60 Hz/24 VA optionally for 120 VAC (+10%...-15%), 50/60 Hz/24 VA

No. of stirring positions

6

Stirrer speed

Program-controlled, 180...450 min-1

Safety class

3, IEC 1010

Protection type

IP 30 to DIN 40050

EMV

EN 61326 Class B, FCC Class A

Climate class

2, VDI/VDE 3540

Ambient temperature

Storage: -25 °C...+65 °C Operation: +5 °C...+40 °C

Dimensions (H x B X D)

67 x 265 x 181 mm

67 x 350 x 266 mm

Weight

1.6 kg

3.2 kg

Test certificates

CE, TÜV/GS, UL, CUL

Warranty

1 year on the instrument

12

Stirrers IS 6 and IS 12 have been specially developed for BOD measurement with the OxiTop® system. With the aid of a software-controlled speed alteration system the stirrer always catches the stirrer bar so that it cannot remain stationary nor can it wobble about. The sample is simply placed on a stirrer and the magnetic stirrer bar will start rotating properly in the center without any problems. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.

Ordering Information for stirrers Stirrers

124

Order No.

IS 6

Stirrer for 6 stirrer positions, mains operation 230 VAC, 50/60 Hz

208 140

IS 12

Stirrer for 12 stirrer positions, mains operation 230 VAC, 50/60 Hz

208 141

Note: versions for 120 VAC/50/60 Hz on request Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Laboratory & Field General Features

Accessories “BOD self-check measurements”

pH

General accessories and spare parts

ORP

Storage racks

ISE

For safe storage of OxiTop® measuring systems and OxiTop®-C measuring heads

Oxygen (D.O.)

Marking rings

209 013

Batt/OxiTop®

Spare batteries (1 set)

209 012

MK 22/600

Overflow measuring flask, contents 22,7 ml

209 030

MK 43/600

Overflow measuring flask, contents 43,5 ml

209 040

MK 97/600

Overflow measuring flask, contents 97,0 ml

209 050

MK 164/600

Overflow measuring flask, contents 164 ml

209 060

MK 250/600

Overflow measuring flask, contents 250 ml

209 070

MK 365/600

Overflow measuring flask, contents 365 ml

209 080

MK 432/600

Overflow measuring flask, contents 432 ml

209 090

PF 600

Sample bottle, amber, minimum order 3 pcs

209 100

GK 600 L

Rubber sleeve, minimum order 3 pcs

209 172

RST 600

Stirrer bars, minimum order 3 pcs

209 120

REF 600

Stirrer bar remover

209 130

NHP 600

Sodium hydroxide pellets, 2 bottles of 50 g

209 140

NTH 600

Nitrification inhibitor

209 331

Dia/600

5 blocks of chart paper

209 020

OxiTop® PM

Test agent for monitoring OxiTop® systems (packing unit for checking 6 measuring systems)

209 333

OxiTop® PT

Test agent for checking under-pressure and leakage for all OxiTop® measuring heads

209 334

Test agents

Mercury disposal HgP 6

Mercury disposal package for 6 measuring positions

209 162

HgP 10

Mercury disposal package for 10 measuring positions

209 163

QBM 600

Mercury binding agent (1 kg)

209 190

PE 600

Rubber ball, fits threads of PF 600 bottle

209 207

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

Respiration Sample Preparation

Set of marking rings (6 pcs) with set of identification shields (1-12) for bottle identification

Colony Counter

209 010

Mark-6

Photometry

Storage rack for 6 OxiTop® measuring systems

Turbidity

Order No.

St-OxiTop®

Software, Printers

General accessories

Customer Service

Ordering Information general accessories

BOD

MultiParameter

Conductivity

For identification of BOD bottles for OxiTop® instruments

125

BSB

BOD

DBO

BOD Thermostats Measurement OxiTop® Box, thermostat cabinets

OxiTop® Box compact – precise

Technical Data OxiTop® Box Energy supply

230 VAC, 50 Hz (+10 ... -15%) optionally 115 VAC 60 Hz (+10 ... -15%)

Power consumption

200 W

Starting current

Max. 5 A (10 A for 115 V, 60 Hz)

Safety class

2, EN 61010

Climate class

2, VDI/VDE 3540

Ambient temperature

Storage: -25 ... +50 °C Operation: +10 ... +32 °C

Temperature control

20 °C ± 1 K

Ventilation

Yes

Additional heating

Yes

Internal sockets

1

CFC-free

Yes

Dimensions

375 x 425 x 600 mm (H x B x D)

Weight

Approx. 30 kg

Test certificate

CE

Warranty

1 year on the instrument

Example of an application: OxiTop® Box with OxiTop® Control 12

Thermostat box with forced air circulation for 20 ± 1 °C OxiTop® Box is a benchtop model with hinged clear-view cover which can accommodate a maximum of either 12 OxiTop® measuring places or 20 Karlsruhe bottles. The chamber is equipped with a connection for an IS 6 or IS 12 stirrer. A special compartment is provided for thermostatting 6 methylene blue samples. The box is made of non-corrosive materials and the compressor is CFC-free. A cross-flow fan ensures uniform temperature distribution. The box has an automatic defrosting system with condensate evaporation.

Ordering Information BOD thermostat boxes OxiTop® Box

126

BOD OxiTop® Box, thermostat box with temperature-controlled forced ventilation for 230 V 50 Hz mains supply

Order No. 208 432

Note: versions for 115 V / 60 Hz on request Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

General Features

Thermostat Cabinets

Laboratory & Field

Thermostats

Sizes /2 and /4 are available with transparent insulating glass doors. Alternatively all thermostat cabinets can be provided with a variable temperature controller, range +5 ... +40 °C.

Customer Service

As the samples must be additionally stirred the thermostat cabinets are fitted with internal sockets to provide the stirrers with electricity.

Depending on the thermostat cabinet size up to 48 samples can be thermostatted simultaneously.

Photometry

BOD5 values must be determined at a constant temperature of 20 °C. If this requirement cannot be realized at the workplace then a thermostat cabinet in which the samples can be placed for the duration of the test is required.

Turbidity

Thermostat cabinets with fixed and variable temperatures

Software, Printers

1 Year Warranty

Colony Counter

Respiration Sample Preparation

BOD

MultiParameter

Conductivity

Oxygen (D.O.)

ISE

ORP

pH

versatile · powerful · inexpensive

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

127

BSB

BOD

DBO

Technical Data TS 606/2

TS 606-G/2

TS 606/3

TS 606/4

TS 606-G/4

TS 1006

Energy supply

230 V/50 Hz Euro

Power consumption

120 W

130 W

140 W

150 W

170 W

150 W

Gross contents

180 l

180 l

260 l

360 l

360 l

500 l

Weight

37 kg

47 kg

46 kg

62 kg

79 kg

76 kg

Ambient temperature

+10 °C...+32 °C

Temperature control

20 °C ± 1 K

Forced air circulation

Yes

Additional heating

Yes

Internal sockets

4 884 x 602 x 600 734 x 513 x 433

1215 x 602 x 600 1589 x 602 x 600 1589 x 602 x 600 1515 x 755 x 715 1047 x 513 x 433 1418 x 513 x 433 1418 x 513 x 433 1338 x 646 x 516

CFC-free Dimensions (H x B x D in mm)

Yes outside: inside:

850 x 602 x 600 734 x 513 x 433

Certified to

CE, TÜV/GS

Warranty

1 year on the instrument

Note: Versions for 120 VAC 60 Hz on request

Technical Data TS 606/2-Var

TS 606-G/2-Var

TS 606/3-Var

TS 606/4-Var

TS 606-G/4-Var

TS 1006-Var

Energy supply

230 V/50 Hz Euro

Power consumption

140 W

140 W

160 W

170 W

190 W

170 W

Gross contents

180 l

180 l

260 l

360 l

360 l

500 l

Weight

37 kg

47 kg

46 kg

62 kg

79 kg

76 kg

Ambient temperature

+10 °C...+32 °C

Temperature control range

+5 °C..+40 °C ±1 K

Forced air circulation

Yes

Additional heating

Yes

Internal sockets

4

CFC-free Dimensions (H x B x D in mm)

Yes outside: inside:

850 x 602 x 600 734 x 513 x 433

884 x 602 x 600 734 x 513 x 433

Certified to

CE, TÜV/GS

Warranty

1 year on the instrument

1215 x 602 x 600 1589 x 602 x 600 1589 x 602 x 600 1515 x 755 x 715 1047 x 513 x 433 1418 x 513 x 433 1418 x 513 x 433 1338 x 646 x 516

Note: Versions for 120 VAC 60 Hz on request

128 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

TS 606/2-Var

As TS 606/2 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 365

TS 606-G/2

As TS 606/2 but with insulated glass front doors

208 253

TS 606-G/2-Var

As TS 606-G/2 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 366

TS 606/3

Thermostat cabinet for 3 BOD instruments OxiTop® Control 6/12/ OxiTop® IS 6 /IS 12-6 / IS 12 / IS 602

208 362

TS 606/3-Var

As TS 606/3 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 367

TS 606/4

Thermostat cabinet for 4 BOD instruments OxiTop® Control 6/12/ OxiTop® IS 6 / IS 12-6 / IS 12 / IS 602

208 355

TS 606/4-Var

As TS 606/4 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 368

TS 606-G/4

As TS 606/4 but with insulated glass front doors

208 356

TS 606-G/4-Var

As TS 606-G/4 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 369

TS 1006

Thermostat cabinet for 4 BOD instruments OxiTop® Control 6/12/ OxiTop® IS 6 / IS 12-6 / IS 12 / IS 602

208 622

TS 1006-Var

As TS 1006 but with digital temperature setting in the range +5 ... +40 °C with digital display of actual value

208 370

Laboratory & Field Customer Service

Software, Printers

Note: versions for 120 VAC 60 Hz on request

BOD

208 252

Respiration Sample Preparation

Thermostat cabinet for 2 BOD instruments OxiTop® Control 6/12, OxiTop® IS 6 /IS 12-6 / IS 12 / IS 602

Colony Counter

Order No.

TS 606/2

Photometry

BOD thermostat cabinets

Turbidity

Ordering Information BOD thermostat cabinets

MultiParameter

Conductivity

Oxygen (D.O.)

ISE

ORP

pH

General Features

Thermostats

Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9

129