S ect i on al an d Ut i l i t y S c af f ol d Sectional Scaffold

Utility Scaffold

Drywall Lifts/Carts

Handy Roll

More than lifting

Know Your Scaffold / Safety / Decals Side Panel Rivet & Cotter Snap Pin Hinge Pin Gravity Pig Tail Pin

Toeboard

End Panel

Walkboard

Diagonal Brace

5 x 5 Step Frame Insert Outrigger

Caster

Cat-A-Corner Squaring Brace

SAFETY

wire of a e the end s madl or ble at orm thim d platfks), meta out a ture scaf or with ufacwood plan ns a intewith ns man n ) mea with loop foldframes measolid saw ns a s. king e scaf nt part ce mea d end plan d and spli ed framicate bers. compone ed and d woo . weld fabr or eye king by n of ededg of a brac Eye . dec g laminate (tubularorted on iate mem orts med separatiois exceistin supp udin rope ricated fold supp suphead Fab d (inclrials. e scaf orm(s) and inter , or strengthfold cons r orm ate scaf from over of woor mateted fram a platf ers, breakage ista a platf ed to, sal,re the ultimensionhung othe rica isting of ontal bear g of l Reg limit g off a Fabcons horiz load refu istin era whe ns a suspers and t cons s, but not fallin fold post meansthe poin mea llel bear 6 Fed or fold g of, from n 199 gral ure sal is fold istin es raise d scaf atio Fail refu p) scaf two para orte work. ier consemploye t 30, ce to istr supLoad t (shi ng on th. ns a supp form barr ent ; orm of cal devi Augus Admin Floaorm resti lengmea hed to vertical to prev stry platf tructed hani the a ls. a n Indu platf s of fixedfold attac ns erected r leve ted mec g of cons from er 29, Health 6 ctio istin s, ed rope scafbracketsem mea pera emb post to lowe conse scaffolds rint er-o Form y and rt 192 Constru a platfold is Nov 1997 ed by syst and way Rep g of orts. ). port rdrail ails, or walkual or pow Safet R Pa d in the dard ber 27, d scaf Hors orm Guaails, midr orm man fold. orte horses).folds. scaffold”consistin nal 9 CF s Usethis StanSeptem th suppplatf a 930 29 ffold for atio e topr fold platf ns d scafns a supp(saw le scaf pole scaffold leng g of a g 02istin Sca date effectiv scaf t mea ende mea horsesas trest“Double on by fixed istin 435 Occup e cons ensi ture n ns Hoisr a susp fold ion s for er cons OH TO truct es knowfold (seea susp struc scaffold dard effectiv isio ld, g ladd lowe se scaf prov BLE ortin syshbo Hored by cons etim scaf means or rooforted ty Stan Thesome LICA ng fold, ensupp som Arc Safe l Rulewith fold ceili a supp port l are dent pole s. ler scaf the of a in S APP the ns ladders.-size, selfFina ally stair kway, ION meta pen hung scaf 1996 usedsusto fixed stairs. t of and coup tanti area Par INIT d fromfold mea Inde rior folds fligh of hed subs floor lor LDS DEF g it scaf derrick The Inte suspende scaf attaca mobile, form of a tube over entire Tay tiltin FFO jack kets ns in the the end fold, ted the to all e or .550(g). t by SCATION AND 125 form ies der scaf L erec cran er brac erec at T to . 1926 to anto d mea Ladng on ted over is kept PAR LICA d ladd orm a pole fold art appl y . ects pped erec h trea a platf ns e scaf SUBPE, APP resti der stan subp not applby Sec .453 conn ects h equi fold whic Ladwide flatmeans fold mead fram red 1926 whic st This does fold fold. ch fold ture. line thatthat conn T 1926SCO a scaf covein Sec. ion. . It PAR .450 PART. of a ding scaf fabricateple: d scaf ble ne) or ne) and on scaf scaf (whi fall arre licat Part h are orte or struc lifeli flexi Lan e area or exam ensi on themember platform 1926 SUB a lifeli appby this s, whic usively tal onal . ted supp ing of susp Larg scaffold, . For pers THIS loca fold scaffold bersconns a build isting (vertical(horizon ns a loyee(s) pe and red orm out excl of a e is ed to,rimem mea nst a temswork area Sco cove l platf set mea se scaf cally ontally nts loye limit h thesimilar scaffoldg posifold it agai nt cons (a) places onnelifts are fold an empsver tire . emp not s, mate pone pone verti on scaf scafated by l tranupon whic work ed persaerial t room n-to restinga com to hang ch horiz s, and ensi a sittin r com re the but are tank le de, pits, Lea rd and ns end to stretg othe abou operhorizonta ers) s, pole le susp e in whe stab l pend ria for nitions pension it be leve s inclu ns, ring ce. post stab employe d adju crite Defi le sus can ns a or runn towa line mea at one ends ectin inut the w the h area excavatio taine Life orage at bothfor conne. (b) stabt)s) that mea ers uprights, int adju for secu s, cont ion devi belo ort one ledg f-con le-po ays, log) Adjua hois lerat red abouthighpoanch oragesmeans orag areas fall. Suc ns a s. “Sel (putorted by scaffolda sing to supp means both runw dece secu t the mea ation nt, can ns (see with rer anch es a the anch ns mea loyee s, ramps, fold oper equipmed to Beabe supp h joinsr mea designed with ne, ormay be at leasother com fold to ls serv onry scaf em ons, ipate strap lifeli h s over it to chai fixed may and whic ed scaf syst er leveh an emps, roofnt. sion for mas pers ly antic ns a lanyard, s whic ins’ or sling elin a hing pen Lowto whic ls, floor pme support st force ber . whe rests tswa a seat a of all onab . attac ) mea equi le it to gn of strap Boa of le susand used mem tureposed of load reas time er or and nd leve fall arrens for and stng ety belt fold stab gned total r loads one , cast mea grou water, adjustab sisti (saf attachinga desi the a scaf or struccom nt adju desi ns the othe nt at anyportable , with ng on g of int adju one buildingscaffold als, tion. y beltand for meansto distribute on’s i-poi s fold istin mea s, and pone wered, em. hold to a d Bod t mult ls resti Masfold”). multi-po ess ner shoulders cons s. orm on scafload t or leve st systn thatber, or supporte unpo fold l wall scaf on’s ensi nded ted loadfold com the wais y harn a man t and poin us on scaf s tura a platf Bodloyee in t, ches fall arre ectio mem ns a Masrun susp inte transmit or scaf ered or two-s at vario d scaf ensitwo ropethe struc g of to strucbe conn her mea . ns a r ous imum rials, scaffold ns a pow emp is, waispersonal a susp orm supporte rigid anot than lowe ing or istin hedort may mea platform ns e Max a pelv s of a ns a ect to scaffolda platf ns a to build fold cons s attac of mate mea fold. fold s to , mea mor and ts. s. to al supp nent e mea resp are supportfold mea hed scaf llel rope toolsappliedscaffold d scaf scafa serie fold d by raise ney hois used le beam 14 fold suspenscaf ende to Braction with squ h scaf attac ension para Addition be ile supportepended with ce sion is susp means de chim needmore than Mobnted on scaf le sus scaffold posi klayers’res whicket bracketsa suspontal and ture. pen ensi adjustab d from are cal surfaas a Briced squars’ bracd by on ns horiz r struc sus which withfolds inclu mou ti-level ent theng ende that verti (such s le susp int ly othe Mul suspensi ps. stableorm(s) equipped fram ente ortefold mea to prev h scaf susp orminuous,surface operation stab “Multi-po ide footi Carporm suppscaf essentialing or orm l able mon stirru a platf and Suc orms of a platf to int adju nt adju platf to prov and y, cont onta lathing . (See g ofsupports levels.ns a platf com ti-poistin platf naryd by twoof a buildups. i-poineys used inof a ting ung and Cateorte bers mult Mulcons fold end also used work means the edgea sturdus, horiz g exis are cal pick a chim scaf for and red inuo terin at thets are tifyins which orization fold overhead suppl memby verti t meansinside desi scaffolds mea lly from cont For plas(46cm). ortedsupport eniden to y, used onta m Clea auth : tura ided hois to work from ition endhoriz sturd k es nt susp by orm ds. ble of cond has ide ption18 inch of a supp a i-poi d l bloc orts. y of a fold the platf dle beas and prov ney ss tura supp ling boaris capa ingand who is ber scaf ber r to prov Nee n side m) awa wall) orss. Exce Chim ecte t or mult ide acce ”) struc its . who or workes, conn scafl mem the y from l memin orde Opees (36cbuildingof acced distance prov scaffold.ns a ing off as craw tura ort for awa one ings loye thema two-poin interinuous tura restsuch ns inch h as aa point shol struc scaffold emp sion t mea slipp struc suppout and ns series of ler orm the cont ces on mea surround a thre the s toto eliminate t Cleaorm from a the ides l (suc ), or onta coup ns ns surfa h of a platf of ga the s fold) mea mea h provto a poin floor horiz er mea widt scaffold. platfsloped nt persrds in dangerou usin s to form tube and g of or face build sure g of nt istin wall e the a the rigg the baseof the ustout)fold whic on pete haza s, or mea s scaf ed ture istin hme s of consnd the insid onry Out ase Comictable rdou ectivefold (run construct cons sloped ility m (Thr r scafof attac g struc red fold mas of ortin the tube scaffolduse on scaf beyo secu incre sed stab pred tary, hazapt corr scaf scaffold bea outriggepoint ort s andsite side ther are d er cting supp titch for run com h on prom or sani crea rigg fold or fold supp ng, , rip-smatic g brick oppowall to rpoensi bers ing toge a supporte Out scaf the scafing. ns astouts) projeof whic to taketinuous lock mem ide footi rope grab ns of layin on the the n inco Constable susp or auto of ension nding or build fold mea fold (thru ard ends prov ce for ess ed is over llatio as a ard, unt during er) mea to devi exte ture er scaf beams inbo adju ed scaf procbe joint to lean l instaess. such g lany amo e laddsecured ns a to struc rigg igger ture, the brac on electricag proc sm, rmin tantialemploye ns the mea cken fold wall and mas Out hani mea the the outr struc fold. pler (chi and layin d scaf by mec ing or defos a subson an Coufold. boardts spaced ing oning or ture. klaying ce of iring tending brick orte orted any ipate sed supp) supp ept ties, scaf ling clea roofs. means ard, tear buildor struc d bricthe surfaon, requ on overhand diss impo ns a Craw k with as ice lany which energy ing rhan that mas des masg the ect meas (bearersort (exc Ove such the inclu durin n dev-woven ard, s the a plances such prot l or supp fold It to atio lany from of . limit wall unitswall work surfa eler specially ne st or s beam ods equa ) scaf lifeliarre Decard, cros pendent the the the brick meth ide an or dent pole or rials fall ng on inde lany retracting pleted into nde ga rials will provmate le to epe (s) restiuprights rate self- durin ssib inmate rate ods, ormrow of . accedo not ergyarrest. pole (ind gns,demonst meth ture platf are 6 the le a h ble fall e desi can whic h lines 1 of Douisting of a doub any struc nativ loyer es than er lines Suc cons ers andes) from ns alter the emp loye l pow contact. ledg , brac nt meawhich ty for emp . trica guys ivalehazard of safestandardns elec lded from Equnst a ee the mea shie cords. agai ter degrified iner lines are noter tool grea s specd pow which or pow sign ose and cords Exployees nsion emp e exte clud

ent rtm Depa

bor of La

The men following that t of Bil- safe cou Jax ty ld prov , Inc. tips are e dan as guid offe Che gero eline red by the s us OSH Ck Saf to scafin avo eng and A, stat ety inee fold iding job- ring Com approvae and Cod wor dep kme site situa miss loca eS: artl n. ion obta tion ined l safe on s ty scaf InS fold from Builcodes tips. Take peCt ding should Safe and no chaand Court be ty and con nce CheCk: part daily sulte esy whil s. Indu d; rope s with e in Insp of out stria is use the use ect the l d, insp OK . Don from 't remscaffold ect PO it on the propove or set up ST Beg allow afte eac WH h job.er auth Use In WIt rem r erec oriti ER na com base h goo es. oval of, tion E Me Whe any scaf bination)plates, d foo n wire fold tIn is leveon solid sills g: grou or foot led ers or plum nd; mak (or reJ bed e sure . Ben eCt daM Put t or othe age them rwis d asid e dam par e for don age tS: d repl Use 't Sho ace end fram men insu bracing rtt. Fores or re stab at Cha brac nge repa es ility. all poin tIe Bra ir, call should ts prov CIn Sca SCaffo Bil- not be ided g: Jax ture ffolding ld ; add , Inc. used. The using sho to the extr uld hea first a brac max BuI vy be es bas imum vertical wire tied to ldIng: if nee e dim heig tie or tie-i the to exce ded stru ens ht of sho to hori 4 time uld n dev ion. ced ices be s exce zontal 26 feet Add ition the narr at the . dista ed vert al 30 feet nce betw icall ties owest are y. don . een Max not Foll 't ove ties imu is not m by ow the rlo the ad to limit scaf safe load SCa 4-to even fold man cap ffo scaf -1 safe to wha ufac aciti ldIng: es fold t ty ing. fact steel turer. as give or mus can supThere's n uSe t be port a figu Whe Met . red A al bett re ava Cat on brea er. Insp ilable. WalkS fIr ks, ect If kno thor woo , pla e d ts, crac oughly plan tforMS po ks or befo k is lIC war re eveused, ; e pag aM ry it mus e. Bu don t be Do Dec job to la not king mak scaf use and 't rId nC wher sho e sure fold e in heigrememb e Mo e user grad uld be it is free e or can ht to er scafvIng dim full come widt from outr ension 4* time fold SCaffo in conta h. into iggers, (unless s thei units ct with are ld; r live lock buildingor mor bas narrowe limit powe ed. ed e end e is r. (exc .) Alw wide st bas *Exc fram ept ned e epti to re-says kee es; or by ons pot) p cas tied :3 time don ters s in © Bil-Ja Use 't ClI CA, x, Inc. OH, scaf the step MB Bra 2006 OR, fold s wor s to prov CeS MT, pro : ladd k leve clim ided ME. b up on mos ers ls. Use teC to whe Use t whe overheaWorkI re requ scaf or dow t stee fold n from l d can ng und n wor ired clim erne k is lev . bing bein opie ath elS scaf g dons to prot : fold e ove ect wor or prov uSe rhea kers ide and dou Pag wire d. Rop on lowe Ble e1 mes e off r wor plat toeboard of 2 gua form h arou uns k leve rd heig s on nd afe area ls hts exposeraIlS; wor of 6 k area s feet d side . or mor s at e.

Part Number

Description

LL-204-22

Committment to safety package (includes - 1 Scaffold safety video, 20 frame decals, 25 LL-204-05 scaffold safety packets, and a laminated certificate.

LL-204-01

Tips on scaffold safety / safety rulse

LL-204-02

OSHA safety and health regulations for construction

LL-204-03

Recommended scaffold erection procedures

LL-204-04

Caution envelope with wire

LL-204-11

Instructions for erecting rolling towers

LL-204-05

Scaffold safety packet (includes - LL-244-01, LL-204-02, LL-204-03, LL-204-04, LL-204-11)

LL-204-27

Scaffold check guide cards

Tip

s o n

sca

ffo

Print

ld

safe

Ty

WO

RK

Arc

ME

N CA

hbold

, Oh

N SE

ph

E

on

io

e

Date

08-20 LL-20 06 4-01

REPLACEMENT DECALS WARNING ASSEMBLY:

• SET LOCK BEFORE CLIMBING AND USING TOWER.

Use only leveling jacks (maximum extension of 12 inches) to adjust to uneven surfaces.

• DO NOT USE IF LOCK IS FAULTY.

• When stacking scaffold frames, always use insert pins and secure both ends of insert pins with fastening (lock) pins.

CCIG/FFO

• Maximum free-standing height equals 3 times the smallest base dimension. When height exceeds 3 times the smallest base dimension, when using side brackets, or when hoisting material, scaffold must be restrained from tipping by tying, guying, or other acceptable means.

Fully deck each work level using metal catwalks, scaffold walkboards or approved scaffold plank. Pin stem and set lock on all casters before using. Use a diagonal horizontal brace (cat-a-corner) at base and every 20 ft. of height on rolling tower.

USE: METAL CONDUCTS ELECTRICITY! DO NOT USE WHERE EQUIPMENT OR USER MAY CONTACT POWER LINES OR OTHER LIVE ELECTRICAL CIRCUITS.

• DO NOT ride a moving scaffold. • DO NOT use without guard rails or toeboards installed at all work levels. • DO NOT stand or sit on guard rails. • DO NOT move scaffold from on top. • DO NOT stand on or climb crossbraces. • DO NOT use crossbraces for a platform support. • DO NOT exert horizontal force on top of a free standing scaffold. • DO NOT use boxes, ladders, or any other means to increase the working height. • DO NOT overload–check with your scaffold dealer for safe working loads. • DO NOT enter platform from the crossbrace side of scaffold. • DO NOT use side brackets on scaffold equipped with casters.

For safety related questions, call (419) 445-8915 © Bil-Jax, Inc. 2004

Page 2

0202-0326

0202-0146

• Pin caster to extension before use. • Leveling jack extension and/or leveling caster must be held securely within frame leg by Leveling Stem Retainer. • Set caster lock before climbing and using scaffold. • Do not use if caster lock is faulty.

Inspect scaffold daily and before each use.

CIA/RFO

0202-0101

Panel guard caution decal

FOLLOW ALL FEDERAL, OSHA, STATE AND LOCAL REGULATIONS FOR THE PROPER USE OF THIS EQUIPMENT.

0202-0146

Caster decal (used on all BilJax casters)

METAL CONDUCTS ELECTRICITY! DO NOT USE WHERE EQUIPMENT OR USER MAY CONTACT POWER LINES OR OTHER LIVE ELECTRICAL CIRCUITS.

0202-0242

Leveling caster / leveling jack extension decal

• For personnel use only.

0202-0326

Scaffold frame caution decal

• DO NOT use for storage of material.

0202-0328

Personnel bracket warning decal

0202-0330

Guard railing decal

0202-0331

Walkboard / catwalk caution decal (Tuf-N-Lite)

0202-0335

Hoist arm warning decal

0202-0361

Expanded metal walkboard / catwalk decal

WARNING

Use approved stairs or access ladder to climb scaffold.

IN ADDITION TO THE ABOVE, FOLLOW ALL FEDERAL, OSHA, STATE AND LOCAL CODES AND REGULATIONS FOR THE PROPER USE OF THIS EQUIPMENT.



Description

PERSONNEL BRACKET

• PIN TO SCAFFOLD LEG BEFORE USE.

• DO NOT use unstable objects such as boxes, bricks, concrete blocks, etc. under scaffold legs.

Part Number

MAXIMUM CAPACITY 500 LBS. DO NOT EXCEED.

WARNING

WARNING

IMPROPER USE OF THIS EQUIPMENT WILL RESULT IN SERIOUS INJURY OR DEATH.

DO NOT use damaged or deteriorated equipment. • Begin assembly with base plates and mud sills.

UII/FFO

CAP. 75# PSF

• When side bracket is in use, scaffold tower must be restrained from tipping by tying, guying or other acceptable means. • DO NOT use on scaffolding equipped with casters. • Pin securely to frame before use. • When in use, all open sides of work platform must have guard rails installed. • Inspect daily and before each use. DO NOT use if damaged.

0202-0242

WARNING:

IMPROPER USE OF THIS EQUIPMENT WILL RE- • Inspect daily and before each use–do not use if damaged. • Keep surface free of debris. SULT IN SERIOUS INJURY OR DEATH.

• Secure deck to prevent uplift with wire or other acceptable means. • Use only for designed purpose. • Do not use without guard rails and toeboards installed. Metal conducts electricity. Do not use this equip- • Acid and other corrosive substances will seriously reduce the • To avoid hook damage, do not drop walkboards. strength of the metal scaffolding components. Consult manu- • Do not straighten bent hooks–bent hooks MUST be replaced ment in areas where contact may be made with by the factory. facturer if using near acid. power lines or other live electrical circuits. Failure to • Do not use this platform in any type of cantilever application. comply with the preceding warning will result in • Do not exceed manufacturer's rated capacity. Never walk out onto or stand on any part of this platform which serious personal injury or death. User MUST main- • Do not use ladder or any other means on platform to increase extends beyond its point of support. work height. tain safe clearances at all times. • Never ride a moving scaffold. • Deck complete work platform area.

CAP. 75# PSF

• Use only on scaffolding which is in good condition, plumb, square, rigid and level, and which is erected in accordance with OSHA and ANSI codes and regulations. • Only personnel familiar with OSHA and ANSI codes and regulations concerning the proper use of scaffolding shall be allowed to erect and/or use this equipment. • ADDITIONALLY, this equipment must be used in full compliance with all applicable OSHA and ANSI codes and regulation for scaffolding and related equipment. 0202-0361

© bil-jax, inc. 2003

GFC

FAILURE TO COMPLY WITH THE ABOVE REGULATIONS MAY RESULT IN SERIOUS INJURY OR DEATH.

LFT/COFR

© Bil-Jax, Inc. 2004

0202-0328

Frames Frame Tube Sizes

5

6

7

1-1/2”

1-5/8”

1-11/16”

Tube Size

Description

5

Frame with 1 1/2” Leg O.D. (weighs 10% less than catalog listings)

6

Frame with 1 5/8” Leg O.D. (weighs same as catalog listings)

7

Frame with 1 11/16” O.D. (weighs 5% more than catalog listings)

Frame Lock Types J-Lock

U-Lock

C-Lock

F-Lock

T-Lock

Lock Type

Description

J-Lock

J-Lock use with notched braces

C-Lock

C-Lock use with holed braces

T-Lock

T-Lock use with holed braces

U-Lock

U-Lock use with holed braces

F-Lock

F-Lock use with holed braces

STEP FRAMES - specify tube size and lock type Description

Weight

5’ W x 2’ H Frame

23

5’ W x 3’ H Frame

27

5’ W x 4’ H Frame

33

5’ W x 5’ H Frame

39

5’ W x 6’ H Frame

45

5’ W x 6’ 4” H Frame

54

5’ W x 6’ 6” H Frame

47

Other step frames available - Contact factory

OPEN END FRAMES - specify tube size, lock type, and cane type Description

Weight

3’ W x 6’ 4” H Frame

43

3’ W x 6’ 6” H Frame

40

4’ W x 6’ 4” H Frame

51

4’ W x 6’ 6” H Frame

46

5’ W X 6’ 4” H Frame

54

5’ W x 6’ 6” H Frame

50

Other open end frames available - Contact factory

Closed Cane 05

Open Cane 25

DOUBLE STEP FRAMES - specify tube size and lock type Description

Weight

5’ W x 3’ H Frame

27

5’ W x 4’ H Frame

35

5’ W x 4’ 6” H Frame

41

5’ W x 5’ H Frame

43

5’ W x 6’ H Frame

51

5’ W x 6’ 4” H Frame

54

5’ W x 6’ 6” H Frame

53

Other double step frames available - Contact Factory

Page 3

Frames (cont.) / Rolling Tower Packages LADDER FRAMES - specify tube size and lock type Description

Weight

Description

Weight

28” W x 3’ H Frame*

16

3’ W x 5’ H Frame

29.5

28” W x 4’ H Frame*

21

3’ W x 6’ H Frame

36

28” W x 5’ H Frame*

26

4’ W x 3’ H Frame

22.5

28” W x 6’ H Frame*

31

4’ W x 4’ H Frame

29

3’ W x 3’ H Frame

18.5

4’ W x 5’ H Frame

36

3’ W x 4’ H Frame

24

4’ W x 6’ H Frame

43

*Exact overall width measurement is needed when ordering 28” wide frames Other ladder frames available - Contact factory

OPEN LADDER FRAMES - specify tube size and lock type (12” Rung Spacing) Description

Weight

5’ W x 6’ 4” H Frame

56

5’ W x 6’ 6” H Frame

57

Other open ladder frames available - Contact factory

CENTER ACCESS FRAMES - specify tube size and lock type (12” Rung Spacing) Description

Weight

5’ W x 2’ H Frame

24

5’ W x 3’ H Frame

28

5’ W x 4’ H Frame

34

5’ W x 5’ H Frame

39

5’ W x 6’ H Frame

55

Other center access frames available - Contact factory

SIDEWALK FRAMES - specify tube size and lock type Description

Weight

6’ W x 7’ 8” H Frame furnished with Hex Lock Nut

65

Other sidewalk frames available - Contact factory

PEDESTAL SCAFFOLD FRAME - specify tube size and lock type Description

Weight

Pedestal Scaffold Frame

37

Replacement Frame Only

17

Replacement Leg Only

10

ROLLING TOWER PACKAGES - 5’ Wide - specify tube size Part Number (5, 6, 7)z

Range

Work Ht.

Weight

7’ Lengths ST-RU0711-( __ )

2’ - 11’

17’

462

ST-RU0716-( __ )

2’ - 16’

22’

568

ST-RU0716-( __ ) OR

2’ - 16’

22’

664

ST-RU0716-( __ ) OR

2’ - 21’

27’

775

ST-RU0716-( __ ) OR

2’ - 26’

32’

881

10’ Lengths

Page 4

ST-RU1011-( __ )

2’ - 11’

17’

542

ST-RU1018-( __ )

2’ - 16’

22’

660

ST-RU1016-( __ ) OR

2’ - 16’

22’

756

ST-RU1021-( __ ) OR

2’ - 21’

27’

876

ST-RU1026-( __ ) OR

2’ - 26’

32’

946

ST-RU1031-( __ ) OR

2’ - 31’

37’

1105

ST-RU1036-( __ ) OR

2’ - 36’

42’

1220

Pin Options / Fastening Pins / Braces INSERT PINS - specify tube size

0007-11_

0001-022

0007-086 0007-031

0007-106

Part Number (5, 6, 7)

Description

0007-11___

9” Pin with 1” collar (fits tube size 5)

Weight 90/ct

0007-022

9” Pin with 1/2” collar (fits tube size 6)

90/ct

0007-086

9” Pin with 1/8” collar (fits tube size 5)

70/ct

0007-031

9” Pin with 1/8” collar (fits tube size 6)

90/ct

0007-106

7” Pin without collar (fits tube size 6)

60/ct

0007-134

9” Pin with special collar (fits tube sizes 6, 7)

100/ct

INSERT ATTACHMENT OPTIONS - specify tube size

0200-001

0200-003

0200-002

Part Number (5 , 6 , 7)

Description

Weight

0200-001

Rivet and cotter attachment

0200-002

Spring rivet attachment

0200-003__

Drive pin attachment

Part Number

Description

0068-037-50

2” Rivet pin with cotter

4

0068-038-50

3” Rivet pin with cotter

5

0090-0496-50

Drive pin for permanent attachment (tube size 6)

2

0090-0494-50

Drive pin for permanent attachment (tube size 7)

2

0068-023-50

Spring rivet

006-0046-50

2” Gravity pig tail pin

0068-061-50

2” Snap pin

6

0068-100-50

2 1/2” Snap pin

8 10

FASTENING PINS

0068-037 0068-038

0068-023

0090-0495 0090-0496 0090-0494

0068-061

0068-012 0068-018

0066-0046

Weight

2 9.1

0068-102-50

4 1/2” Snap pin

0068-012-50

2” Hinge pin

5

0068-018-50

3” Hinge pin

6.6

CAT-A-CORNER SQUARING BRACES - specify tube size Part Number (5, 6, 7)

Description

Weight

0019-4__-507

Squaring brace for a 5’ wide x 7’ long tower

16

0019-4__-508

Squaring brace for a 5’ wide x 8’ long tower

18

0019-4__510

Squaring brace for a 5’ wide x 10’ long tower

20

Other Cat-A-Corner squaring braces available. Contact Factory

GALVANIZED DIAGONAL BRACES - specify end type and lock spacing Description Lock Spacing Frame Spacing Hole End

Notch End

Weight

5’ Brace

9

7’ Brace

12

8’ Brace

14

10’ Brace

17

Other diagonal braces available. Contact Factory

DOUBLE HOLE GALVANIZED DIAGONAL BRACES - 36” & 48” lock spacing

Hole end type only

Part Number

Description

Weight

0010-34-07

7’ Spacing brace

12

0010-34-08

8’ Spacing brace

14

0010-34-10

10’ Spacing brace

17

Other diagonal braces available. Contact Factory Page 5

Braces / Leveling Jacks / Base Plates / Guard Rails ARM BRACES - 27 3/4” lock spacing

Hole End

Notch End

Part Number

Description

0013-15-07

7’ spacing brace - hole end

Weight 15

0013-15-08

8’ spacing brace - hole end

16

0013-15-10

10’ spacing brace - hole end

19

0013-03-07

7’ spacing brace - notch end

15

0013-03-10

10’ spacing brace - notch end

19

Other arm braces available. Contact Factory

LEVELING JACKS - specify tube size

0032-08__ 0032-09__ 0034-08__

Part Number (5, 6, 7)

Description

Weight

0032-08__*

Rigid jack 24” stem with 15” adjustment

0032-09__*

Swivel jack 24” stem with 15” adjustment

12 11.5

10.2

0034-08__

Extension 15” adjustment with retainer kit

0069-0071

Leveling stem retainer

0032-085pl

Plated rigid jack 24” stem with 15” adjustment

10.5

0032-086pl

Plated swivel jack 24” stem with 15” adjustment

12.5

Other leveling jacks available. Contact Factory

1

*To fit tube sizes 6 and 7, select 6 in the part number

BASE PLATES / RUBBER PAD - specify tube size

0030-11__

0030-12__

Part Number (5, 6, 7)

Description

Weight

0030-11__

Rigid base plate - 4” stem

0030-12__

Swivel base plate - 4” stem

4

0082-0740

Rubber pad for base plate

.5

3

CASTERS - specify tube size

0026-7__2

Part Number (5, 6, 7)

Description

0026-7__2

8” wheel size - 4” stem size - 500 lb capacity (cast iron)

Weight 13

0026-9__2

8” wheel size - 4” stem size - 500 lb capacity (plastic)

9

0026-9__2

GUARD RAIL POSTS - specify tube size

0023-__23

0023-__25

Part Number (5, 6, 7)

Description

0023-__23

Corner guard rail post - B-lock

5.7

0023-__25

Corner guard rail post - F-lock

5.5

0023-__18

Guard rail post - U-lock

5.5

Corner guard rail post - U-lock

5.5

0023-__28 0023-__28

Weight

GUARD RAILS - GALVANIZED Part Number

Description

0022-02-28

End rail - 28” spacing

3

0022-01-03

End rail - 36” spacing

3

0022-02-04

End rail - 46 1/2” spacing (fits tube size 5)

3

0022-01-04

End rail - 48” spacing (fits tube sizes 6, 7)

3

0022-02-05

End rail - 58 1/2” spacing (fits tube size 5)

4

0022-01-05

End rail - 60” spacing (fits tube sizes 6, 7)

0022-01-07

Side rail - 7’ spacing

5.25

0022-01-08

Side rail - 8’ spacing

6.5

0022-25-10

Side rail - 10’ spacing

8

Other side guard rail sizes available. Contact factory

Page 6

Weight

4

Guard Rails / Toeboards / Easi-Guard System / Walkboards INTERMEDIATE GUARD RAIL FOR OPEN END TYPE FRAMES 0012-267-05

Part Number

Description

0012-263-07

7’ Intermediate side guard rail panel

Weight 21

0012-263-08

8’ Intermediate side guard rail panel

23

0012-263-10

10’ Intermediate side guard rail panel

0012-267-05

5’ Wide Intermediate end guard rail panel

27 21.5

Other intermediate guard rail panel sizes available

6” STEEL TOEBOARDS Part Number

Description

Weight

0012-016-03

End toeboard 26 5/8” (fits tube sizes 5,6)

4

0012-016-04

End toeboard 26 5/16” (fits tube size 7)

4

0012-016-05

End toeboard 36” (fits tube sizes 5, 6, 7)

5

0012-016-06

End toeboard 46 1/2” (fits tube size 5)

6

0012-012-07

End toeboard 48” (fits tube sizes 6, 7)

6

0012-016-08

End toeboard 58 1/2” (fits tube size 5)

7

0012-016-09

End toeboard 60” (fits tube sizes 6, 7)

7.8

0012-016-12

Side toeboard 7’ (fits tube sizes 5, 6, 7)

9

0012-016-14

Side toeboard 8’ (fits tube sizes 5, 6, 7)

10

0012-016-18

Side toeboard 10’ fits tube sizes (5, 6, 7)

12

Part Number

Description

0063-0199

Toeboard clip

.5

0063-0203

Corner toeboard bracket

.5

TOEBOARD CLIPS Weight

EASI-GUARD SYSTEM - specify tube size

End panel

Mid-post

Side panel 

Toeboard

Part Number (5, 6, 7)

Description

Weight

0012-23__

Mid-post

9

0012-22__-28

End panel 28” with toeboard

14

0012-22__-03

End panel 36” with toeboard

17

0012-22__-04

End panel 48” with toeboard

21

0012-22__-05

End panel 60” with toeboard

34

0012-209-07

Side panel 7’

12

0012-209-08

Side panel 8’

14

0012-210-10

Side panel 10’

17

0012-202-07

Side toeboard 7’ steel

8

0012-202-08

Side toeboard 8’ steel

10

0012-202-10

Side toeboard 10’ steel

14.5

Part Number

Description

0253-35

Swing gate for 5’ wide open end frames

SWING GATE Weight 22

X-PANDED STEEL WALKBOARD - STEEL FRAME WITH EXPANDED STEEL DECK Part Number

Description

Weight

0044-205

19” Wide x 7’ long - 75 psf capacity

45

0044-225

24” Wide x 7’ long - 75 psf capacity

52

0044-227

24” Wide x 8’ long - 75 psf capacity

58

0044-235

28” Wide x 7’ long - 75 psf capacity

56

0044-237

28” Wide x 8’ long - 75 psf capacity

64

0044-245

32” Wide x 7’ long - 75 psf capacity

62

Other side guard rail sizes available. Contact factory Page 7

Walkboards TUF-N-LITE WALKBOARD ALUMINUM FRAME WITH PLYWOOD DECK Type A Hook*

2

7/16"

Type B Hook 1-5/16"

4

Type A part numbers listed. For Type B replace red 2 with a 4 in the part number

Part Number

Description

Weight

0054-216

19’ Wide x 7’ long - 75 psf capacity

32

0054-220-50

19’ Wide x 10’ long - 50 psf capacity

40

0054-220

19’ Wide x 10’ long - 75 psf capacity

46.5

0054-226

22’ Wide x 7’ long - 75 psf capacity

35

0054-230

22’ Wide x 10’ long - 50 psf capacity

44.5

0054-236

24’ Wide x 7’ long - 75 psf capacity

37

0054-240

24’ Wide x 10’ long - 50 psf capacity

50

0054-246

28’ Wide x 7’ long - 75 psf capacity

39

0054-250

28’ Wide x 10’ long - 50 psf capacity

54

0054-256

32’ Wide x 7’ long - 50 psf capacity

47

Other Tuf-N-Lite walkboeard sizes available. Contact factory.

TUF-N-LITE WALKBOARD REPLACEMENT PARTS

Aluminum hook replacement kit

Plywood deck replacement

Aluminum cross member

Part Number Description

Part Number

0054-007-07

7’ Aluminum rail 4 mem / punch

0090-0545

1/4 - 20 x 1S / tap screw

Description

0054-002-07

7’ Aluminum rail 3 mem / punch

0090-0987

3/16 drive rivet

0054-007-08

8’ Aluminum rail 4 mem / punch

0191-0019

Plywood for 0054-216

0054-002-08

8’ Aluminum rail 3 mem / punch

0191-0022

Plywood for 0054-220

0054-009-10

10’ Aluminum rail 4 mem / punch

0191-0049

Plywood for 0054-248

0054-102

Lock - swivel assembly, heavy duty A

0191-0050

Plywood for 0054-250

0054-101

Lock - swivel assembly, heavy duty B

0054-080

Conversion kit 2-bolt to 4 bolt

0054-130

Aluminum hook type A replacement kit

0054-131

Aluminum hook type B replacement kit

0054-018-05

Aluminum cross member for 19 walkboard

0054-018-08

Aluminum cross member for 28 walkboard

0054-018-09

Aluminum cross member for 32 walkboard

Other Tuf-N-Lite replacement parts available. Contact factory.

X-TRU-LITE WALKBOARD 7100 SERIES - ALUMINUM FRAME AND DECK Part Number

Description

0055-216

19 1/4” Wide x 7’ long - 75 psf capacity

Weight 32

0055-220

19 1/4” Wide x 10’ long - 75 psf capacity

40

Other X-Tru-Lite walkboard sizes available. Contact factory.

X-TRU-LITE WALKBOARD REPLACEMENT PARTS Part Number

Description

Weight

0055-216-3

End Support / 19” X-Tru-Lite

1

0082-0553

Aluminum hook repair kit - 1 hole

4

OUTRIGGER - specify tube size (5, 6, 7)

Page 8

Part Number (5, 6, 7)

Description

0048-2__

30” wide outrigger

Weight 14

Brackets / Hoist Arm / Outrigger / Putlogs SIDE AND END BRACKETS - specify tube size Part Number

Description

Capacity

Weight

SIDE BRACKETS

0039-165-5

0039-520-5

0039-621-5

0039-620-5

0039-620-__

20” Saddle hanger with tube end

500 lb

9

0039-624-__

24” Saddle hanger with tube end

500 lb

10

0039-630-__

30” Saddle hanger with tube end

500 lb

13

0039-165-__

20” - 30” Adjustable saddle hanger with tube end

500 lb

14

0039-124

12” Saddle hanger with plate end

500 lb

6

0039-621

21” Saddle hanger with plate end

500 lb

9

0039-720-__

20” Angle iron hanger - side hang-on with tube end

500 lb

9

0039-724-__

24” Angle iron hanger - side hang-on with tube end

500 lb

11.5

0039-730-__

30” Angle iron hanger - side hang-on with tube end

500 lb

13

0039-171-__

20” - 30” Adjustable angle iron hanger with tube end

500 lb

14

END BRACKETS 0039-520-__

20” End and side hang-on with tube end

500 lb

10.5

0039-524-__

24” End and side hang-on with tube end

500 lb

13

0039-530-__

30” End and side hang-on with tube end

500 lb

14

END GUARD RAIL FOR SIDE BRACKET 0012-266

0012-266

End guard rail for 20” to 30” side bracket

19

HOIST ARM - WELL WHEEL - TIE BRACE 0063-0344

0082-0103

0041-028

Part Number

Description

Weight

0041-028

Swivel head hoist arm

29

0082-0103

10” Well wheel

9.3

0063-0344

Scaffold tie brace

11

PUTLOGS Part Number Description Putlog

Trussed putlog

Weight

Part Number Description

Weight

0036-178

8 ‘ Putlog

24

0036-602

18’ Putlog - trussed

79

0036-180

10’ putlog

30

0036-603

20’ Putlog - trussed

92

0036-182

12’ Putlog

36

0036-604

22’ Putlog - trussed

101

0036-600

14’ Putlog - trussed

47

0036-605

24’ Putlog - trussed

111

0036-601

16’ Putlog - trussed

70

0036-606

26’ Putlog - trussed

118

Other putlog sizes available. Contact factory.

PUTLOG ACCESSORIES 0037-22

0036-040 0036-042 0036-043

0061-11 0061-12 0061-10

0037-16

Part Number

Description

0037-16

Putlog angle hanger

0061-11

Offset insert saddle (tube size 5)

3

0061-12

Offset insert saddle (tube size 6)

3

0061-10

Offset insert saddle (tube size 7)

3

0061-29

Insert saddle (tube size 5)

3

0061-06

Insert saddle (tube size 6)

3

0061-23

Insert saddle (tube size 7)

3

0037-22

Putlog support 8’ long with clamps

20

0036-040

Putlog spreader - 5’ frame sp (tube size 6)

24

0036-042

Putlog spreader - 5’ frame sp (tube size 5)

14

0036-043

Putlog spreader - 7’ frame sp (tube size 5)

24

0061-29 0061-06 Other putlog accessories available. Contract factory.

All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.

Weight 3.5

Page 9

Clamps / Brackets / Replacement Parts / Stair Tower Components DROPPED FORGED CLAMPS 0069-0094 0069-0117

0069-0095 0069-0118

Part Number

Description

0069-0095

Swivel clamp with “Eye” bolt - fits 1.625”, 1.69”, 1.9” tube diamater

Weight 3

0069-0094

Rigid clamp with “Eye” bolt - fits 1.625”, 1.69”, 1.9” tube diamater

3

0069-0118

Swivel clamp with “Eye” bolt - fits 1.69” and 1.9” tube diamater

3

0069-0117

Rigid clamp with “Eye” bolt - fits 1.69” and 1.9” tube diamater

3

BRACKETS AND CLAMPS

0069-0015

0069-0043

0069-0013

0069-0026

0069-0017

0069-0070 0069-0057

Part Number

Description

Weight

0069-0017

Parallel tube clamp

1.5

0069-0016

Bracket for hole or notched brace

.5

0069-0026

Bracket for hole brace

.5

0069-0013

Clamp for notched brace

1.5

0069-0043

Clamp for hole brace

1.5

0069-0070

B-Lock clamp (tube size 5)

.5

0069-0057

B-Lock clamp (tube size 6, 7)

.5

REPLACEMENT PARTS 0064-0783

0068-004

0066-0006

0068-008

0067-0005

0068-042/1

0067-0739 0067-0046

0068-095 0090-0517

Part Number Description

Part Number Desciption

0064-0783

Half outrigger clamp

0068-008

0066-0006

Putlog clamp hook

0068-042/1

Brace rivet with 3 washers

0067-0005

Gooser brace slide

0068-042/50

Package 50 brace rivets with 150 washers

0067-0039

Leveling nut (1 7/16”)

0068-095

U-Bolt only - Putlog angle hanger 0037-16

0067-0046

Leveling nut (1 1/4”)

0090-0517

Thumb screw - 3/8” diamater x 1 1/4” long

0068-004

1/2” set screw

Lever tail nut 5” long

BRACE LOCK PARTS

0064-0604

0068-009

0068-013

Part Number Description

Part Number Desciption

0068-123A

C-Lock with stud pin

0008-042

F-Lock complete

0068-123

C-Lock stud

0008-048

U-Lock complete

0064-0604

C-Lock slide

0068-009

J-Lock stud 1/2”

0008-022-4/50

C-Lock washer

0066-0044

J-Lock pin 3/8” x 3/4”

0090-0311/50

C-Lock roll pin

0068-013

J-Lock wing nut 1/2”

0008-044

T-Lock complete

TUF-N-LITE HINGED LADDER BOARD - ALUMINUM FRAME, PLYWOOD DECK, ATTACHED LADDER Part Number

Description

Weight

0054-125-07

28” Wide x 7’ long - 75 psf capacity

69

0054-125-08

28” Wide x 8’ long - 50 psf capacity

75

0054-125-10

28” Wide x 10’ long - 50 psf capacity

81

STAIR TOWER COMPONENTS Part Number Description

Part Number Description

0042-019

Stair platform rest (tube size 5)

0043-185

Outside handrail (top section)

0042-027

Stair platform rest (tube size 6)

0042-175

Inside handrail (top section)

0042-035

Stair platform rest (tube size 7)

0042-221

24” Wide stair section 6’ 5”

0042-047

Open frame safety guard

0042-022

24” Wide stair section 6’ 6”

0042-094

Outside handrail

0042-223

24” wide stair section 6’ 7”

0042-093

Inside handrail

0044-052

Intermediate catwalk 28” wide x 7’ long with guardrail

0044-054

Hinged platform 28” wide x 7’ long expanded steel

0044-235

28” Wide x 7’ Long expanded steel catwalk - 75 psf capacity

BilJax offers a heavy duty stair tower for worker access to buildings, bridges, observation towers, or renovation done inside or outside. The stairs can also be used for access in a scaffold set-up. Page 10

Access Ladder / Climbing Ladder ACCESS LADDER SYSTEM (see below image)

0042-130

0042-126 Top hinged platform

Part Number

Description

0042-126

6’ Access ladder (use with 6’ 6” high frame)

Weight

0042-130

6’ Handrails (pair)

10.5

0042-129

Platform rest (tube size 5) (2 required at 1st tier only)

7.5

0042-128

Platform rest (tube size 6, 7) (2 Required at 1st tier only)

8

0054-346

Top hinged platform 28” x 7’

43

0054-348

Top hinged platform 28” x 8’

49

0054-350

Top hinged platform 28” x 10’

55

37

CLIMBING LADDER - TUBULAR TYPE (see below image)

0063-0074 0063-0073 0004-0376 0004-0377

Part Number

Description

Weight

0004-0377

6’ Top section

0004-0375

6’ Ladder section

17.5

0004-0376

3’ Ladder section

9.2

0063-0074

Support bracket (tube size 5)

5.5

0063-0073

Support bracket (tube size 6, 7)

5.5

19

CANOPY TOP / WEATHER PROTECTION CLIP (see below image) Part Number

Description

0071-021

Canopy top with adjustable extension - 5’ W x 1’ H (tube size 6)

Weight 27

0071-022

Canopy Top with adjustable extension - 5’ W x 1’ H (tube size 7)

27

0071-024

Canopy top with adjustable extension - 5’ W x 1’ H (tube size 5)

27

0082-0228

Weather protection clips 8” L 9 (qty. 100)

16

ADDITIONAL ILLUSTRATIONS ACCESS LADDER SYSTEM

CLIMBING LADDER TUBULAR TYPE

CANOPY TOP WEATHER PROTECTION CLIP Maximum 10’ 6’

Up to 4’

All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.

Page 11

Pro-Jax Scaffold Packages / Guard Rail

PRO-JAX UTILITY SCAFFOLD PACKAGES WITH PLYWOOD DECK WALKBOARDS Part Number

0127-006-0 Single Unit

0127-006-1 Single Unit w/ Guard Rail

0127-006-2 2 Single Units w/ Guard Rail & 18” Wide Outriggers

Description Length

Platform Ht Range

0127-006-0

6’

0127-006-1

6’

0127-006-2 0127-006-3 0127-008-0

Includes

Weight

Guard Rails

Outriggers

2’ - 4’

No

No

147

2’ - 6’

Yes

No

240

6’

2’ -11.5’

Yes

Yes

430

6’

2’ - 17’

Yes

Yes

538

8’

2’ - 4’

No

No

173

0127-008-1

8

2’ - 6’

Yes

No

279

0127-008-2

8’

2’ - 11.5’

Yes

Yes

490

0127-008-3

8’

2’ - 17’

Yes

Yes

609

0127-010-0

10’

2’ - 4’

No

No

200

0127-010-1

10’

2’ - 6’

Yes

No

316

0127-010-2

10’

2’ - 11.5’

Yes

Yes

525

0127-010-3

10’

2’ - 17’

Yes

Yes

645

PRO-JAX UTILITY SCAFFOLD ADDITIONAL HEIGHT PACKAGES Part Number

Description

0127-007-3

6’ Length x 39” height unit

Weight 75

0127-007-5

6’ Length x 65” height unit

95

0127-009-3

8’ Length x 39” height unit

93

0127-009-5

8’ Length x 65” height unit

103

0127-011-3

10’ Length x 39” height unit

97

0127-011-5

10’ Length x 65” height unit

123

PRO-JAX GUARD RAIL PACKAGES, OUTRIGGER PACKAGES, AND LEVELING EXTENSION 0127-149-08

0127-138

Page 12

0127-150-18

Part Number

Description

Weight

0127-149-06

6’ Complete guard rail package (2 pieces)

81.5

0127-149-08

8’ Complete guard rail package (2 pieces)

98

0127-149-10

10’ Complete guard rail package (2 pieces)

115

0127-150-18

18” Wide outrigger package (4 pieces)

39

0127-150-24

24” Wide outrigger package (4 pieces)

44

0127-138

Leveling extension

Pro-Jax Replacement Parts & Components / Handy Roll PRO-JAX REPLACEMENT PARTS Part Number

Description

0063-0377

L-Pin replacement kit for platform arm brace

Weight .25

0063-0418

Wind latch replacement kit

.25

0063-0605

Saf-T-Lok replacement kit

.40

PRO-JAX COMPONENTS

0127-102

0127-101

0127-108-06

0127-113

0127-149-06

Part Number

Description

Weight

0127-102

39” High ladder frame

15

0127-101

65” ladder frame

25

0127-147

Base extension unit

29

0127-163-06

6’ Platform arm brace

21

0127-163-08

8’ Platform arm brace

26

0127-163-10

10’ Platform arm brace

32

0127-108-06

6’ Plywood deck

29

0127-108-08

8’ Plywood deck

40

0127-108-10

10’ Plywood deck

52

0127-141-06

6’ Top hinged plywood deck

47

0127-141-08

8’ Top hinged plywood deck

60

0127-141-10

10’ Top hinged plywood deck

73

0127-113

6’ Expanded metal deck

36

0127-114

8’ Expanded metal deck

48

0127-115

10’ Explanded metal deck

60

0127-106-06

6’ Combination guard panel

35.5

0127-106-08

8’ Combination guard panel

42

0127-106-10

10’ Combination guard panel

48

0127-105-18

18” Wide outrigger

8

0127-105-24

24” Wide outrigger

11

0127-118

48” Wide outrigger

26

0127-136-06

6’ Intermediate guard rail

20

0127-136-08

8’ Intermediate guard rail

24

0127-136-10

10’ Intermediate guard rail

28

0127-138

Adjustable leg with rubber pad

0026-835

5” Caster - 250 lb capacity with 2” snap pin (trailing edge brake lock)

0026-952

8” Caster - 500 lb capacity with 2” snap pin - P5

0127-150-18

0127-163-06

3

0026-835

4.75 10

0026-952

HANDY ROLL SCAFFOLDING 4-CASTER UNITS Part Number

Description

0063-0435-34

3’ Handy roll scaffold 4-caster unit with steel platforms - 24” wide x 48” long x 39” high

82

0063-0435-44

4’ Handy roll scaffold 4-caster unit with steel platforms - 24” wide x 48” long x 51” high

87

0063-0435-54

5’ Handy roll scaffold 4-caster unit with steel platforms - 27” wide x 64” long x 63” high

106

All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.

Weight

Page 13

Drywall Cart / Drywall Lift DRYWALL CART

0063-0575-11YE

Part Number

Description

Capacity

Weight

0063-0573-01YE

Model DC 3000 LD, light duty with plastic casters (2 swivel - 2 rigid) - 23” wide x 50” long x 47” high

3000

84

0063-0574-11YE

Model DC 3000 MD, medium duty with steel casters (2 swivel - 2 rigid) - 23” wide x 49” long x 47” high

3000

104

0063-0575-11YE

Model DC 3000 EX, heavy duty with steel casters (2 swivel - 2 rigid) - 28” wide x 50” long x 47” high

3000

137

Part Number

Description

Capacity

Weight

0063-0547

Model DL 100 Steel - 5’ to 10’ lift adjustment

200

104

0063-0580

Model DL 125 Steel - 5’ to 12’ lift adjustment

200

125

0063-0595

Model DL 150 Steel - 5’ to 15’ lift adjustment

160

141

DRYWALL LIFT

0063-0580

Scaffold Safety Guidelines - recommended by Scaffolding, Shoring & Forming Institute It shall be the responsibility of all employers and employees to read and comply with the following common sense guidelines which are designed to promote safety in the erecting and dismantling of scaffolds. These guidelines do not purport to be all-inclusive nor to supplant or replace other additional safety and precautionary measures to cover usual or unusual conditions. Local, State or Federal statute or regulations shall supersede these guidelines if there is a conflict and it is the responsibility of each employee to comply. I. II. III. IV. V. VI. VII. VIII. IX. X.

GENERAL GUIDELINES

POST THESE SCAFFOLDING SAFETY GUIDELINES in a conspicuous place and be sure that all persons who erect, dismantle or use scaffolding are aware of them. FOLLOW ALL STATE, LOCAL AND FEDERAL CODES, ORDINANCES AND REGULATIONS pertaining to scaffolding because they may be more restrictive. For example, height or width requirements may vary. SURVEY THE JOB SITE—A survey shall be made of the job site for hazards, such as untampered earth fills, ditches, debris, high tension wires, unguarded openings, and other hazardous conditions created by other trades. These conditions shall be corrected or avoided as noted in the following sections. INSPECT ALL EQUIPMENT BEFORE USING—Never use any equipment that is damaged or defective in any way. KEEP ALL EQUIPMENT IN GOOD REPAIR—Avoid using corroded equipment—the strength of corroded equipment is not known. INSPECT ERECTED SCAFFOLDS DAILY—or at the beginning of every shift to be sure that they are maintained in safe condition. NEVER USE EQUIPMENT FOR PURPOSES OR IN WAYS FOR WHICH IT WAS NOT INTENDED. REPORT ANY UNSAFE CONDITION. NEVER TAKE CHANCES—Do not work on scaffolds if your physical condition is such that you feel dizzy or unsteady in any way. WORKING UNDER THE INFLUENCE OF ALCOHOL OR ILLEGAL DRUGS IS STRICTLY PROHIBITED. CONSULT YOUR SCAFFOLDING SUPPLIER—NEVER TAKE CHANCES—Consult manuals and instructions provided by the supplier; scaffolding is his business.

GUIDELINES FOR ERECTION AND USE OF SCAFFOLDS

A. PROVIDE ADEQUATE SILLS for scaffold posts and use base plates. B. USE ADJUSTING SCREWS or other approved conditions. C. PLUMB AND LEVEL ALL SCAFFOLDS as the erection proceeds. Do not force braces to fit—level the scaffold until proper fit can be made easily. D. BRACING. Each frame or panel shall be braced by horizontal bracing, cross bracing, diagonal bracing or any combination thereof for securing vertical members together laterally. All brace connections shall be made secure, in accordance with manufacturers’ recommendations. E. DO NOT CLIMB CROSS BRACES. Use only an access (climbing) ladder, access steps, frame designed to be climbed or equivalent safe access to scaffold. F. TIE RUNNING SCAFFOLD TO WALL or structure when the height exceeds* four (4) times the minimum scaffold base dimension. The first vertical and longitudinal tie shall be placed at this point. Vertical ties shall be repeated at intervals not greater than 26 feet. Longitudinal ties shall be placed at each end and at intervals not greater than 30 feet. Ties must prevent the scaffold from tipping into or away from the wall or structure. G. WHEN SCAFFOLDS ARE TO BE PARTIALLY OR FULLY ENCLOSED, specific precautions must be taken to assure frequency and adequacy of ties attaching the scaffolding to the building due to increased load conditions resulting from effects of wind and weather. The scaffolding components to which the ties are attached must also be checked for additional loads. H. WHEN FREE STANDING SCAFFOLD TOWERS exceed* four times their minimum base dimension vertically, they must be restrained from tipping. I. DO NOT ERECT SCAFFOLDS NEAR ELECTRICAL POWER LINES UNLESS PROPER PRECAUTIONS ARE TAKEN. Consult the power service company for advice. J. DO NOT USE ladders or makeshift devices on top of scaffolds to increase the height. K. DO NOT EXCEED MANUFACTURERS’ RECOMMENDED LOAD RATING. L. EQUIP AND MAINTAIN ALL PLATFORMS with proper guardrails, midrails, and toeboards along all open sides and ends of scaffold platforms. M. ALL BRACKETS shall be seated correctly with side brackets parallel to the frames and end brackets at 90 degrees to the frames. Brackets shall not be bent or twisted from normal position. Brackets (except mobile brackets designed to carry materials) are to be used as work platforms only and shall not be used for storage of material or equipment. When brackets are used, the scaffold shall be tied to the structure or otherwise restrained to prevent tipping. N. ALL SCAFFOLDING ACCESSORIES shall be used and installed in accordance with the manufacturers’ recommended procedure. Accessories shall not be altered in the field. Scaffolds, frames and their components of various manufacturers shall not be intermixed. O. FOR PLANKING, THE FOLLOWING GUIDELINES APPLY: 1. Use only lumber that is properly inspected and graded as scaffold plank. 2. Planking shall have at least 12 inches of overlap and extend 6 inches beyond center of support, or, be cleated at both ends to prevent sliding off supports.

Page 14

3.

P.

3.

Q.

R.

S.

Fabricated scaffold planks and platforms, unless created or restrained by hooks, shall extend over their end supports not less than 6 inches nor more than 12 inches. 4. Secure plank to scaffold when necessary. FOR ROLLING SCAFFOLDS THE FOLLOWING ADDITIONAL GUIDELINES APPLY. 1. CASTERS WITH PLAIN STEMS shall be attached to the panel or adjustment screw by pins or other suitable means. 2. DO NOT EXTEND ADJUSTING SCREWS ON ROLLING SCAFFOLDS MORE THAN 12 INCHES. WHEELS OR CASTERS shall be provided with a locking device and kept locked during erection and dismantling or any time scaffolds are not being moved. 4. SECURE OR REMOVE ALL MATERIAL AND EQUIPMENT from platform before moving scaffold. 5. USE HORIZONTAL DIAGONAL BRACING near the bottom and at 20 foot intervals measured from the rolling surface. 6. DO NOT USE brackets or other platform extensions without consideration of overturning effect. 7. THE HEIGHT OF A ROLLING SCAFFOLD excluding its uppermost guardrails, must not exceed* four times its smallest base dimension unless it is stabilized by an engineered counterweight system or some other equivalent means. 8. CLEAT OR SECURE ALL PLANKS. 9. DO NOT ATTEMPT TO MOVE A ROLLING SCAFFOLD WITHOUT SUFFICIENT HELP—watch out for holes in floor and overhead obstructions—stabilize against tipping. 10. DO NOT RIDE ROLLING SCAFFOLDS. 11. JOINTS shall be restrained from separation. FOR “PUTLOGS” AND “TRUSSES” the following additional guidelines apply. 1. DO NOT CANTILEVER OR EXTEND PUTLOGS/TRUSSES as side brackets without thorough consideration for loads to be applied. 2. PUTLOGS/TRUSSES SHOULD BE EXTENDED AT LEAST 6 inches beyond point of support. 3. PLACE RECOMMENDED BRACING BETWEEN PUTLOGS/TRUSSES when the span of putlog/truss is more than 12 feet. WHEN DISMANTLING SCAFFOLDING THE FOLLOWING ADDITIONAL GUIDELINES APPLY: 1. CHECK TO SEE IF SCAFFOLDING HAS BEEN STRUCTURALLY ALTERED in any way which would make it unsafe, and if so, reconstruct where necessary before commencing with dismantling procedures. 2. VISUALLY INSPECT PLANK prior to dismantling to be sure that they are safe to work on. 3. COMPONENTS SHOULD BE LOWERED as soon as dismantled in safe manner so as to protect personnel below. 4. DO NOT ACCUMULATE EXCESS COMPONENTS OR EQUIPMENT on the level being dismantled. 5. DISMANTLED EQUIPMENT should be stockpiled in an orderly manner. FOLLOW ERECTION PROCEDURES AND USE MANUALS.

SCAFFOLD FRAME MEASUREMENT CHARTS These facts are needed whenever you are not sure that the frame is a BilJax brand product. If you do not have previous experience with the frame ordered, or if you do not have the item number, answer the below questions and provide them with your order.

Step frame

Center access frame

Open frame

Ladder frame

A. Specify Rotation of Pin Holes 1. 900 or 450 top & bottom 900 Standard B. Width of Frame Center to Center 1. To get this measurement, place tape outside to inside of leg tube. C. Frame Height 1. Measure overall top to bottom 2. DO NOT include insert (stacking pin) in measurement D. Lock Spacing 1. Measure distance from top of top lock pin to top of bottom lock pin 2. When a lock had two pins, use the lower pin of both locks E. Lock Location 1. Measure between top of leg and the center of the top lock pin 2. In case of a two pin lock, use the lower pin F. Tube Size of Leg (diameter) 1. Measure leg outside to outside 1-1/2”, 1-5/8”, 1-11/16” standard sizes