S ect i on al an d Ut i l i t y S c af f ol d Sectional Scaffold
Utility Scaffold
Drywall Lifts/Carts
Handy Roll
More than lifting
Know Your Scaffold / Safety / Decals Side Panel Rivet & Cotter Snap Pin Hinge Pin Gravity Pig Tail Pin
Toeboard
End Panel
Walkboard
Diagonal Brace
5 x 5 Step Frame Insert Outrigger
Caster
Cat-A-Corner Squaring Brace
SAFETY
wire of a e the end s madl or ble at orm thim d platfks), meta out a ture scaf or with ufacwood plan ns a intewith ns man n ) mea with loop foldframes measolid saw ns a s. king e scaf nt part ce mea d end plan d and spli ed framicate bers. compone ed and d woo . weld fabr or eye king by n of ededg of a brac Eye . dec g laminate (tubularorted on iate mem orts med separatiois exceistin supp udin rope ricated fold supp suphead Fab d (inclrials. e scaf orm(s) and inter , or strengthfold cons r orm ate scaf from over of woor mateted fram a platf ers, breakage ista a platf ed to, sal,re the ultimensionhung othe rica isting of ontal bear g of l Reg limit g off a Fabcons horiz load refu istin era whe ns a suspers and t cons s, but not fallin fold post meansthe poin mea llel bear 6 Fed or fold g of, from n 199 gral ure sal is fold istin es raise d scaf atio Fail refu p) scaf two para orte work. ier consemploye t 30, ce to istr supLoad t (shi ng on th. ns a supp form barr ent ; orm of cal devi Augus Admin Floaorm resti lengmea hed to vertical to prev stry platf tructed hani the a ls. a n Indu platf s of fixedfold attac ns erected r leve ted mec g of cons from er 29, Health 6 ctio istin s, ed rope scafbracketsem mea pera emb post to lowe conse scaffolds rint er-o Form y and rt 192 Constru a platfold is Nov 1997 ed by syst and way Rep g of orts. ). port rdrail ails, or walkual or pow Safet R Pa d in the dard ber 27, d scaf Hors orm Guaails, midr orm man fold. orte horses).folds. scaffold”consistin nal 9 CF s Usethis StanSeptem th suppplatf a 930 29 ffold for atio e topr fold platf ns d scafns a supp(saw le scaf pole scaffold leng g of a g 02istin Sca date effectiv scaf t mea ende mea horsesas trest“Double on by fixed istin 435 Occup e cons ensi ture n ns Hoisr a susp fold ion s for er cons OH TO truct es knowfold (seea susp struc scaffold dard effectiv isio ld, g ladd lowe se scaf prov BLE ortin syshbo Hored by cons etim scaf means or rooforted ty Stan Thesome LICA ng fold, ensupp som Arc Safe l Rulewith fold ceili a supp port l are dent pole s. ler scaf the of a in S APP the ns ladders.-size, selfFina ally stair kway, ION meta pen hung scaf 1996 usedsusto fixed stairs. t of and coup tanti area Par INIT d fromfold mea Inde rior folds fligh of hed subs floor lor LDS DEF g it scaf derrick The Inte suspende scaf attaca mobile, form of a tube over entire Tay tiltin FFO jack kets ns in the the end fold, ted the to all e or .550(g). t by SCATION AND 125 form ies der scaf L erec cran er brac erec at T to . 1926 to anto d mea Ladng on ted over is kept PAR LICA d ladd orm a pole fold art appl y . ects pped erec h trea a platf ns e scaf SUBPE, APP resti der stan subp not applby Sec .453 conn ects h equi fold whic Ladwide flatmeans fold mead fram red 1926 whic st This does fold fold. ch fold ture. line thatthat conn T 1926SCO a scaf covein Sec. ion. . It PAR .450 PART. of a ding scaf fabricateple: d scaf ble ne) or ne) and on scaf scaf (whi fall arre licat Part h are orte or struc lifeli flexi Lan e area or exam ensi on themember platform 1926 SUB a lifeli appby this s, whic usively tal onal . ted supp ing of susp Larg scaffold, . For pers THIS loca fold scaffold bersconns a build isting (vertical(horizon ns a loyee(s) pe and red orm out excl of a e is ed to,rimem mea nst a temswork area Sco cove l platf set mea se scaf cally ontally nts loye limit h thesimilar scaffoldg posifold it agai nt cons (a) places onnelifts are fold an empsver tire . emp not s, mate pone pone verti on scaf scafated by l tranupon whic work ed persaerial t room n-to restinga com to hang ch horiz s, and ensi a sittin r com re the but are tank le de, pits, Lea rd and ns end to stretg othe abou operhorizonta ers) s, pole le susp e in whe stab l pend ria for nitions pension it be leve s inclu ns, ring ce. post stab employe d adju crite Defi le sus can ns a or runn towa line mea at one ends ectin inut the w the h area excavatio taine Life orage at bothfor conne. (b) stabt)s) that mea ers uprights, int adju for secu s, cont ion devi belo ort one ledg f-con le-po ays, log) Adjua hois lerat red abouthighpoanch oragesmeans orag areas fall. Suc ns a s. “Sel (putorted by scaffolda sing to supp means both runw dece secu t the mea ation nt, can ns (see with rer anch es a the anch ns mea loyee s, ramps, fold oper equipmed to Beabe supp h joinsr mea designed with ne, ormay be at leasother com fold to ls serv onry scaf em ons, ipate strap lifeli h s over it to chai fixed may and whic ed scaf syst er leveh an emps, roofnt. sion for mas pers ly antic ns a lanyard, s whic ins’ or sling elin a hing pen Lowto whic ls, floor pme support st force ber . whe rests tswa a seat a of all onab . attac ) mea equi le it to gn of strap Boa of le susand used mem tureposed of load reas time er or and nd leve fall arrens for and stng ety belt fold stab gned total r loads one , cast mea grou water, adjustab sisti (saf attachinga desi the a scaf or struccom nt adju desi ns the othe nt at anyportable , with ng on g of int adju one buildingscaffold als, tion. y beltand for meansto distribute on’s i-poi s fold istin mea s, and pone wered, em. hold to a d Bod t mult ls resti Masfold”). multi-po ess ner shoulders cons s. orm on scafload t or leve st systn thatber, or supporte unpo fold l wall scaf on’s ensi nded ted loadfold com the wais y harn a man t and poin us on scaf s tura a platf Bodloyee in t, ches fall arre ectio mem ns a Masrun susp inte transmit or scaf ered or two-s at vario d scaf ensitwo ropethe struc g of to strucbe conn her mea . ns a r ous imum rials, scaffold ns a pow emp is, waispersonal a susp orm supporte rigid anot than lowe ing or istin hedort may mea platform ns e Max a pelv s of a ns a ect to scaffolda platf ns a to build fold cons s attac of mate mea fold. fold s to , mea mor and ts. s. to al supp nent e mea resp are supportfold mea hed scaf llel rope toolsappliedscaffold d scaf scafa serie fold d by raise ney hois used le beam 14 fold suspenscaf ende to Braction with squ h scaf attac ension para Addition be ile supportepended with ce sion is susp means de chim needmore than Mobnted on scaf le sus scaffold posi klayers’res whicket bracketsa suspontal and ture. pen ensi adjustab d from are cal surfaas a Briced squars’ bracd by on ns horiz r struc sus which withfolds inclu mou ti-level ent theng ende that verti (such s le susp int ly othe Mul suspensi ps. stableorm(s) equipped fram ente ortefold mea to prev h scaf susp orminuous,surface operation stab “Multi-po ide footi Carporm suppscaf essentialing or orm l able mon stirru a platf and Suc orms of a platf to int adju nt adju platf to prov and y, cont onta lathing . (See g ofsupports levels.ns a platf com ti-poistin platf naryd by twoof a buildups. i-poineys used inof a ting ung and Cateorte bers mult Mulcons fold end also used work means the edgea sturdus, horiz g exis are cal pick a chim scaf for and red inuo terin at thets are tifyins which orization fold overhead suppl memby verti t meansinside desi scaffolds mea lly from cont For plas(46cm). ortedsupport eniden to y, used onta m Clea auth : tura ided hois to work from ition endhoriz sturd k es nt susp by orm ds. ble of cond has ide ption18 inch of a supp a i-poi d l bloc orts. y of a fold the platf dle beas and prov ney ss tura supp ling boaris capa ingand who is ber scaf ber r to prov Nee n side m) awa wall) orss. Exce Chim ecte t or mult ide acce ”) struc its . who or workes, conn scafl mem the y from l memin orde Opees (36cbuildingof acced distance prov scaffold.ns a ing off as craw tura ort for awa one ings loye thema two-poin interinuous tura restsuch ns inch h as aa point shol struc scaffold emp sion t mea slipp struc suppout and ns series of ler orm the cont ces on mea surround a thre the s toto eliminate t Cleaorm from a the ides l (suc ), or onta coup ns ns surfa h of a platf of ga the s fold) mea mea h provto a poin floor horiz er mea widt scaffold. platfsloped nt persrds in dangerou usin s to form tube and g of or face build sure g of nt istin wall e the a the rigg the baseof the ustout)fold whic on pete haza s, or mea s scaf ed ture istin hme s of consnd the insid onry Out ase Comictable rdou ectivefold (run construct cons sloped ility m (Thr r scafof attac g struc red fold mas of ortin the tube scaffolduse on scaf beyo secu incre sed stab pred tary, hazapt corr scaf scaffold bea outriggepoint ort s andsite side ther are d er cting supp titch for run com h on prom or sani crea rigg fold or fold supp ng, , rip-smatic g brick oppowall to rpoensi bers ing toge a supporte Out scaf the scafing. ns astouts) projeof whic to taketinuous lock mem ide footi rope grab ns of layin on the the n inco Constable susp or auto of ension nding or build fold mea fold (thru ard ends prov ce for ess ed is over llatio as a ard, unt during er) mea to devi exte ture er scaf beams inbo adju ed scaf procbe joint to lean l instaess. such g lany amo e laddsecured ns a to struc rigg igger ture, the brac on electricag proc sm, rmin tantialemploye ns the mea cken fold wall and mas Out hani mea the the outr struc fold. pler (chi and layin d scaf by mec ing or defos a subson an Coufold. boardts spaced ing oning or ture. klaying ce of iring tending brick orte orted any ipate sed supp) supp ept ties, scaf ling clea roofs. means ard, tear buildor struc d bricthe surfaon, requ on overhand diss impo ns a Craw k with as ice lany which energy ing rhan that mas des masg the ect meas (bearersort (exc Ove such the inclu durin n dev-woven ard, s the a plances such prot l or supp fold It to atio lany from of . limit wall unitswall work surfa eler specially ne st or s beam ods equa ) scaf lifeliarre Decard, cros pendent the the the brick meth ide an or dent pole or rials fall ng on inde lany retracting pleted into nde ga rials will provmate le to epe (s) restiuprights rate self- durin ssib inmate rate ods, ormrow of . accedo not ergyarrest. pole (ind gns,demonst meth ture platf are 6 the le a h ble fall e desi can whic h lines 1 of Douisting of a doub any struc nativ loyer es than er lines Suc cons ers andes) from ns alter the emp loye l pow contact. ledg , brac nt meawhich ty for emp . trica guys ivalehazard of safestandardns elec lded from Equnst a ee the mea shie cords. agai ter degrified iner lines are noter tool grea s specd pow which or pow sign ose and cords Exployees nsion emp e exte clud
ent rtm Depa
bor of La
The men following that t of Bil- safe cou Jax ty ld prov , Inc. tips are e dan as guid offe Che gero eline red by the s us OSH Ck Saf to scafin avo eng and A, stat ety inee fold iding job- ring Com approvae and Cod wor dep kme site situa miss loca eS: artl n. ion obta tion ined l safe on s ty scaf InS fold from Builcodes tips. Take peCt ding should Safe and no chaand Court be ty and con nce CheCk: part daily sulte esy whil s. Indu d; rope s with e in Insp of out stria is use the use ect the l d, insp OK . Don from 't remscaffold ect PO it on the propove or set up ST Beg allow afte eac WH h job.er auth Use In WIt rem r erec oriti ER na com base h goo es. oval of, tion E Me Whe any scaf bination)plates, d foo n wire fold tIn is leveon solid sills g: grou or foot led ers or plum nd; mak (or reJ bed e sure . Ben eCt daM Put t or othe age them rwis d asid e dam par e for don age tS: d repl Use 't Sho ace end fram men insu bracing rtt. Fores or re stab at Cha brac nge repa es ility. all poin tIe Bra ir, call should ts prov CIn Sca SCaffo Bil- not be ided g: Jax ture ffolding ld ; add , Inc. used. The using sho to the extr uld hea first a brac max BuI vy be es bas imum vertical wire tied to ldIng: if nee e dim heig tie or tie-i the to exce ded stru ens ht of sho to hori 4 time uld n dev ion. ced ices be s exce zontal 26 feet Add ition the narr at the . dista ed vert al 30 feet nce betw icall ties owest are y. don . een Max not Foll 't ove ties imu is not m by ow the rlo the ad to limit scaf safe load SCa 4-to even fold man cap ffo scaf -1 safe to wha ufac aciti ldIng: es fold t ty ing. fact steel turer. as give or mus can supThere's n uSe t be port a figu Whe Met . red A al bett re ava Cat on brea er. Insp ilable. WalkS fIr ks, ect If kno thor woo , pla e d ts, crac oughly plan tforMS po ks or befo k is lIC war re eveused, ; e pag aM ry it mus e. Bu don t be Do Dec job to la not king mak scaf use and 't rId nC wher sho e sure fold e in heigrememb e Mo e user grad uld be it is free e or can ht to er scafvIng dim full come widt from outr ension 4* time fold SCaffo in conta h. into iggers, (unless s thei units ct with are ld; r live lock buildingor mor bas narrowe limit powe ed. ed e end e is r. (exc .) Alw wide st bas *Exc fram ept ned e epti to re-says kee es; or by ons pot) p cas tied :3 time don ters s in © Bil-Ja Use 't ClI CA, x, Inc. OH, scaf the step MB Bra 2006 OR, fold s wor s to prov CeS MT, pro : ladd k leve clim ided ME. b up on mos ers ls. Use teC to whe Use t whe overheaWorkI re requ scaf or dow t stee fold n from l d can ng und n wor ired clim erne k is lev . bing bein opie ath elS scaf g dons to prot : fold e ove ect wor or prov uSe rhea kers ide and dou Pag wire d. Rop on lowe Ble e1 mes e off r wor plat toeboard of 2 gua form h arou uns k leve rd heig s on nd afe area ls hts exposeraIlS; wor of 6 k area s feet d side . or mor s at e.
Part Number
Description
LL-204-22
Committment to safety package (includes - 1 Scaffold safety video, 20 frame decals, 25 LL-204-05 scaffold safety packets, and a laminated certificate.
LL-204-01
Tips on scaffold safety / safety rulse
LL-204-02
OSHA safety and health regulations for construction
LL-204-03
Recommended scaffold erection procedures
LL-204-04
Caution envelope with wire
LL-204-11
Instructions for erecting rolling towers
LL-204-05
Scaffold safety packet (includes - LL-244-01, LL-204-02, LL-204-03, LL-204-04, LL-204-11)
LL-204-27
Scaffold check guide cards
Tip
s o n
sca
ffo
Print
ld
safe
Ty
WO
RK
Arc
ME
N CA
hbold
, Oh
N SE
ph
E
on
io
e
Date
08-20 LL-20 06 4-01
REPLACEMENT DECALS WARNING ASSEMBLY:
• SET LOCK BEFORE CLIMBING AND USING TOWER.
Use only leveling jacks (maximum extension of 12 inches) to adjust to uneven surfaces.
• DO NOT USE IF LOCK IS FAULTY.
• When stacking scaffold frames, always use insert pins and secure both ends of insert pins with fastening (lock) pins.
CCIG/FFO
• Maximum free-standing height equals 3 times the smallest base dimension. When height exceeds 3 times the smallest base dimension, when using side brackets, or when hoisting material, scaffold must be restrained from tipping by tying, guying, or other acceptable means.
Fully deck each work level using metal catwalks, scaffold walkboards or approved scaffold plank. Pin stem and set lock on all casters before using. Use a diagonal horizontal brace (cat-a-corner) at base and every 20 ft. of height on rolling tower.
USE: METAL CONDUCTS ELECTRICITY! DO NOT USE WHERE EQUIPMENT OR USER MAY CONTACT POWER LINES OR OTHER LIVE ELECTRICAL CIRCUITS.
• DO NOT ride a moving scaffold. • DO NOT use without guard rails or toeboards installed at all work levels. • DO NOT stand or sit on guard rails. • DO NOT move scaffold from on top. • DO NOT stand on or climb crossbraces. • DO NOT use crossbraces for a platform support. • DO NOT exert horizontal force on top of a free standing scaffold. • DO NOT use boxes, ladders, or any other means to increase the working height. • DO NOT overload–check with your scaffold dealer for safe working loads. • DO NOT enter platform from the crossbrace side of scaffold. • DO NOT use side brackets on scaffold equipped with casters.
For safety related questions, call (419) 445-8915 © Bil-Jax, Inc. 2004
Page 2
0202-0326
0202-0146
• Pin caster to extension before use. • Leveling jack extension and/or leveling caster must be held securely within frame leg by Leveling Stem Retainer. • Set caster lock before climbing and using scaffold. • Do not use if caster lock is faulty.
Inspect scaffold daily and before each use.
CIA/RFO
0202-0101
Panel guard caution decal
FOLLOW ALL FEDERAL, OSHA, STATE AND LOCAL REGULATIONS FOR THE PROPER USE OF THIS EQUIPMENT.
0202-0146
Caster decal (used on all BilJax casters)
METAL CONDUCTS ELECTRICITY! DO NOT USE WHERE EQUIPMENT OR USER MAY CONTACT POWER LINES OR OTHER LIVE ELECTRICAL CIRCUITS.
0202-0242
Leveling caster / leveling jack extension decal
• For personnel use only.
0202-0326
Scaffold frame caution decal
• DO NOT use for storage of material.
0202-0328
Personnel bracket warning decal
0202-0330
Guard railing decal
0202-0331
Walkboard / catwalk caution decal (Tuf-N-Lite)
0202-0335
Hoist arm warning decal
0202-0361
Expanded metal walkboard / catwalk decal
WARNING
Use approved stairs or access ladder to climb scaffold.
IN ADDITION TO THE ABOVE, FOLLOW ALL FEDERAL, OSHA, STATE AND LOCAL CODES AND REGULATIONS FOR THE PROPER USE OF THIS EQUIPMENT.
Description
PERSONNEL BRACKET
• PIN TO SCAFFOLD LEG BEFORE USE.
• DO NOT use unstable objects such as boxes, bricks, concrete blocks, etc. under scaffold legs.
Part Number
MAXIMUM CAPACITY 500 LBS. DO NOT EXCEED.
WARNING
WARNING
IMPROPER USE OF THIS EQUIPMENT WILL RESULT IN SERIOUS INJURY OR DEATH.
DO NOT use damaged or deteriorated equipment. • Begin assembly with base plates and mud sills.
UII/FFO
CAP. 75# PSF
• When side bracket is in use, scaffold tower must be restrained from tipping by tying, guying or other acceptable means. • DO NOT use on scaffolding equipped with casters. • Pin securely to frame before use. • When in use, all open sides of work platform must have guard rails installed. • Inspect daily and before each use. DO NOT use if damaged.
0202-0242
WARNING:
IMPROPER USE OF THIS EQUIPMENT WILL RE- • Inspect daily and before each use–do not use if damaged. • Keep surface free of debris. SULT IN SERIOUS INJURY OR DEATH.
• Secure deck to prevent uplift with wire or other acceptable means. • Use only for designed purpose. • Do not use without guard rails and toeboards installed. Metal conducts electricity. Do not use this equip- • Acid and other corrosive substances will seriously reduce the • To avoid hook damage, do not drop walkboards. strength of the metal scaffolding components. Consult manu- • Do not straighten bent hooks–bent hooks MUST be replaced ment in areas where contact may be made with by the factory. facturer if using near acid. power lines or other live electrical circuits. Failure to • Do not use this platform in any type of cantilever application. comply with the preceding warning will result in • Do not exceed manufacturer's rated capacity. Never walk out onto or stand on any part of this platform which serious personal injury or death. User MUST main- • Do not use ladder or any other means on platform to increase extends beyond its point of support. work height. tain safe clearances at all times. • Never ride a moving scaffold. • Deck complete work platform area.
CAP. 75# PSF
• Use only on scaffolding which is in good condition, plumb, square, rigid and level, and which is erected in accordance with OSHA and ANSI codes and regulations. • Only personnel familiar with OSHA and ANSI codes and regulations concerning the proper use of scaffolding shall be allowed to erect and/or use this equipment. • ADDITIONALLY, this equipment must be used in full compliance with all applicable OSHA and ANSI codes and regulation for scaffolding and related equipment. 0202-0361
© bil-jax, inc. 2003
GFC
FAILURE TO COMPLY WITH THE ABOVE REGULATIONS MAY RESULT IN SERIOUS INJURY OR DEATH.
LFT/COFR
© Bil-Jax, Inc. 2004
0202-0328
Frames Frame Tube Sizes
5
6
7
1-1/2”
1-5/8”
1-11/16”
Tube Size
Description
5
Frame with 1 1/2” Leg O.D. (weighs 10% less than catalog listings)
6
Frame with 1 5/8” Leg O.D. (weighs same as catalog listings)
7
Frame with 1 11/16” O.D. (weighs 5% more than catalog listings)
Frame Lock Types J-Lock
U-Lock
C-Lock
F-Lock
T-Lock
Lock Type
Description
J-Lock
J-Lock use with notched braces
C-Lock
C-Lock use with holed braces
T-Lock
T-Lock use with holed braces
U-Lock
U-Lock use with holed braces
F-Lock
F-Lock use with holed braces
STEP FRAMES - specify tube size and lock type Description
Weight
5’ W x 2’ H Frame
23
5’ W x 3’ H Frame
27
5’ W x 4’ H Frame
33
5’ W x 5’ H Frame
39
5’ W x 6’ H Frame
45
5’ W x 6’ 4” H Frame
54
5’ W x 6’ 6” H Frame
47
Other step frames available - Contact factory
OPEN END FRAMES - specify tube size, lock type, and cane type Description
Weight
3’ W x 6’ 4” H Frame
43
3’ W x 6’ 6” H Frame
40
4’ W x 6’ 4” H Frame
51
4’ W x 6’ 6” H Frame
46
5’ W X 6’ 4” H Frame
54
5’ W x 6’ 6” H Frame
50
Other open end frames available - Contact factory
Closed Cane 05
Open Cane 25
DOUBLE STEP FRAMES - specify tube size and lock type Description
Weight
5’ W x 3’ H Frame
27
5’ W x 4’ H Frame
35
5’ W x 4’ 6” H Frame
41
5’ W x 5’ H Frame
43
5’ W x 6’ H Frame
51
5’ W x 6’ 4” H Frame
54
5’ W x 6’ 6” H Frame
53
Other double step frames available - Contact Factory
Page 3
Frames (cont.) / Rolling Tower Packages LADDER FRAMES - specify tube size and lock type Description
Weight
Description
Weight
28” W x 3’ H Frame*
16
3’ W x 5’ H Frame
29.5
28” W x 4’ H Frame*
21
3’ W x 6’ H Frame
36
28” W x 5’ H Frame*
26
4’ W x 3’ H Frame
22.5
28” W x 6’ H Frame*
31
4’ W x 4’ H Frame
29
3’ W x 3’ H Frame
18.5
4’ W x 5’ H Frame
36
3’ W x 4’ H Frame
24
4’ W x 6’ H Frame
43
*Exact overall width measurement is needed when ordering 28” wide frames Other ladder frames available - Contact factory
OPEN LADDER FRAMES - specify tube size and lock type (12” Rung Spacing) Description
Weight
5’ W x 6’ 4” H Frame
56
5’ W x 6’ 6” H Frame
57
Other open ladder frames available - Contact factory
CENTER ACCESS FRAMES - specify tube size and lock type (12” Rung Spacing) Description
Weight
5’ W x 2’ H Frame
24
5’ W x 3’ H Frame
28
5’ W x 4’ H Frame
34
5’ W x 5’ H Frame
39
5’ W x 6’ H Frame
55
Other center access frames available - Contact factory
SIDEWALK FRAMES - specify tube size and lock type Description
Weight
6’ W x 7’ 8” H Frame furnished with Hex Lock Nut
65
Other sidewalk frames available - Contact factory
PEDESTAL SCAFFOLD FRAME - specify tube size and lock type Description
Weight
Pedestal Scaffold Frame
37
Replacement Frame Only
17
Replacement Leg Only
10
ROLLING TOWER PACKAGES - 5’ Wide - specify tube size Part Number (5, 6, 7)z
Range
Work Ht.
Weight
7’ Lengths ST-RU0711-( __ )
2’ - 11’
17’
462
ST-RU0716-( __ )
2’ - 16’
22’
568
ST-RU0716-( __ ) OR
2’ - 16’
22’
664
ST-RU0716-( __ ) OR
2’ - 21’
27’
775
ST-RU0716-( __ ) OR
2’ - 26’
32’
881
10’ Lengths
Page 4
ST-RU1011-( __ )
2’ - 11’
17’
542
ST-RU1018-( __ )
2’ - 16’
22’
660
ST-RU1016-( __ ) OR
2’ - 16’
22’
756
ST-RU1021-( __ ) OR
2’ - 21’
27’
876
ST-RU1026-( __ ) OR
2’ - 26’
32’
946
ST-RU1031-( __ ) OR
2’ - 31’
37’
1105
ST-RU1036-( __ ) OR
2’ - 36’
42’
1220
Pin Options / Fastening Pins / Braces INSERT PINS - specify tube size
0007-11_
0001-022
0007-086 0007-031
0007-106
Part Number (5, 6, 7)
Description
0007-11___
9” Pin with 1” collar (fits tube size 5)
Weight 90/ct
0007-022
9” Pin with 1/2” collar (fits tube size 6)
90/ct
0007-086
9” Pin with 1/8” collar (fits tube size 5)
70/ct
0007-031
9” Pin with 1/8” collar (fits tube size 6)
90/ct
0007-106
7” Pin without collar (fits tube size 6)
60/ct
0007-134
9” Pin with special collar (fits tube sizes 6, 7)
100/ct
INSERT ATTACHMENT OPTIONS - specify tube size
0200-001
0200-003
0200-002
Part Number (5 , 6 , 7)
Description
Weight
0200-001
Rivet and cotter attachment
0200-002
Spring rivet attachment
0200-003__
Drive pin attachment
Part Number
Description
0068-037-50
2” Rivet pin with cotter
4
0068-038-50
3” Rivet pin with cotter
5
0090-0496-50
Drive pin for permanent attachment (tube size 6)
2
0090-0494-50
Drive pin for permanent attachment (tube size 7)
2
0068-023-50
Spring rivet
006-0046-50
2” Gravity pig tail pin
0068-061-50
2” Snap pin
6
0068-100-50
2 1/2” Snap pin
8 10
FASTENING PINS
0068-037 0068-038
0068-023
0090-0495 0090-0496 0090-0494
0068-061
0068-012 0068-018
0066-0046
Weight
2 9.1
0068-102-50
4 1/2” Snap pin
0068-012-50
2” Hinge pin
5
0068-018-50
3” Hinge pin
6.6
CAT-A-CORNER SQUARING BRACES - specify tube size Part Number (5, 6, 7)
Description
Weight
0019-4__-507
Squaring brace for a 5’ wide x 7’ long tower
16
0019-4__-508
Squaring brace for a 5’ wide x 8’ long tower
18
0019-4__510
Squaring brace for a 5’ wide x 10’ long tower
20
Other Cat-A-Corner squaring braces available. Contact Factory
GALVANIZED DIAGONAL BRACES - specify end type and lock spacing Description Lock Spacing Frame Spacing Hole End
Notch End
Weight
5’ Brace
9
7’ Brace
12
8’ Brace
14
10’ Brace
17
Other diagonal braces available. Contact Factory
DOUBLE HOLE GALVANIZED DIAGONAL BRACES - 36” & 48” lock spacing
Hole end type only
Part Number
Description
Weight
0010-34-07
7’ Spacing brace
12
0010-34-08
8’ Spacing brace
14
0010-34-10
10’ Spacing brace
17
Other diagonal braces available. Contact Factory Page 5
Braces / Leveling Jacks / Base Plates / Guard Rails ARM BRACES - 27 3/4” lock spacing
Hole End
Notch End
Part Number
Description
0013-15-07
7’ spacing brace - hole end
Weight 15
0013-15-08
8’ spacing brace - hole end
16
0013-15-10
10’ spacing brace - hole end
19
0013-03-07
7’ spacing brace - notch end
15
0013-03-10
10’ spacing brace - notch end
19
Other arm braces available. Contact Factory
LEVELING JACKS - specify tube size
0032-08__ 0032-09__ 0034-08__
Part Number (5, 6, 7)
Description
Weight
0032-08__*
Rigid jack 24” stem with 15” adjustment
0032-09__*
Swivel jack 24” stem with 15” adjustment
12 11.5
10.2
0034-08__
Extension 15” adjustment with retainer kit
0069-0071
Leveling stem retainer
0032-085pl
Plated rigid jack 24” stem with 15” adjustment
10.5
0032-086pl
Plated swivel jack 24” stem with 15” adjustment
12.5
Other leveling jacks available. Contact Factory
1
*To fit tube sizes 6 and 7, select 6 in the part number
BASE PLATES / RUBBER PAD - specify tube size
0030-11__
0030-12__
Part Number (5, 6, 7)
Description
Weight
0030-11__
Rigid base plate - 4” stem
0030-12__
Swivel base plate - 4” stem
4
0082-0740
Rubber pad for base plate
.5
3
CASTERS - specify tube size
0026-7__2
Part Number (5, 6, 7)
Description
0026-7__2
8” wheel size - 4” stem size - 500 lb capacity (cast iron)
Weight 13
0026-9__2
8” wheel size - 4” stem size - 500 lb capacity (plastic)
9
0026-9__2
GUARD RAIL POSTS - specify tube size
0023-__23
0023-__25
Part Number (5, 6, 7)
Description
0023-__23
Corner guard rail post - B-lock
5.7
0023-__25
Corner guard rail post - F-lock
5.5
0023-__18
Guard rail post - U-lock
5.5
Corner guard rail post - U-lock
5.5
0023-__28 0023-__28
Weight
GUARD RAILS - GALVANIZED Part Number
Description
0022-02-28
End rail - 28” spacing
3
0022-01-03
End rail - 36” spacing
3
0022-02-04
End rail - 46 1/2” spacing (fits tube size 5)
3
0022-01-04
End rail - 48” spacing (fits tube sizes 6, 7)
3
0022-02-05
End rail - 58 1/2” spacing (fits tube size 5)
4
0022-01-05
End rail - 60” spacing (fits tube sizes 6, 7)
0022-01-07
Side rail - 7’ spacing
5.25
0022-01-08
Side rail - 8’ spacing
6.5
0022-25-10
Side rail - 10’ spacing
8
Other side guard rail sizes available. Contact factory
Page 6
Weight
4
Guard Rails / Toeboards / Easi-Guard System / Walkboards INTERMEDIATE GUARD RAIL FOR OPEN END TYPE FRAMES 0012-267-05
Part Number
Description
0012-263-07
7’ Intermediate side guard rail panel
Weight 21
0012-263-08
8’ Intermediate side guard rail panel
23
0012-263-10
10’ Intermediate side guard rail panel
0012-267-05
5’ Wide Intermediate end guard rail panel
27 21.5
Other intermediate guard rail panel sizes available
6” STEEL TOEBOARDS Part Number
Description
Weight
0012-016-03
End toeboard 26 5/8” (fits tube sizes 5,6)
4
0012-016-04
End toeboard 26 5/16” (fits tube size 7)
4
0012-016-05
End toeboard 36” (fits tube sizes 5, 6, 7)
5
0012-016-06
End toeboard 46 1/2” (fits tube size 5)
6
0012-012-07
End toeboard 48” (fits tube sizes 6, 7)
6
0012-016-08
End toeboard 58 1/2” (fits tube size 5)
7
0012-016-09
End toeboard 60” (fits tube sizes 6, 7)
7.8
0012-016-12
Side toeboard 7’ (fits tube sizes 5, 6, 7)
9
0012-016-14
Side toeboard 8’ (fits tube sizes 5, 6, 7)
10
0012-016-18
Side toeboard 10’ fits tube sizes (5, 6, 7)
12
Part Number
Description
0063-0199
Toeboard clip
.5
0063-0203
Corner toeboard bracket
.5
TOEBOARD CLIPS Weight
EASI-GUARD SYSTEM - specify tube size
End panel
Mid-post
Side panel
Toeboard
Part Number (5, 6, 7)
Description
Weight
0012-23__
Mid-post
9
0012-22__-28
End panel 28” with toeboard
14
0012-22__-03
End panel 36” with toeboard
17
0012-22__-04
End panel 48” with toeboard
21
0012-22__-05
End panel 60” with toeboard
34
0012-209-07
Side panel 7’
12
0012-209-08
Side panel 8’
14
0012-210-10
Side panel 10’
17
0012-202-07
Side toeboard 7’ steel
8
0012-202-08
Side toeboard 8’ steel
10
0012-202-10
Side toeboard 10’ steel
14.5
Part Number
Description
0253-35
Swing gate for 5’ wide open end frames
SWING GATE Weight 22
X-PANDED STEEL WALKBOARD - STEEL FRAME WITH EXPANDED STEEL DECK Part Number
Description
Weight
0044-205
19” Wide x 7’ long - 75 psf capacity
45
0044-225
24” Wide x 7’ long - 75 psf capacity
52
0044-227
24” Wide x 8’ long - 75 psf capacity
58
0044-235
28” Wide x 7’ long - 75 psf capacity
56
0044-237
28” Wide x 8’ long - 75 psf capacity
64
0044-245
32” Wide x 7’ long - 75 psf capacity
62
Other side guard rail sizes available. Contact factory Page 7
Walkboards TUF-N-LITE WALKBOARD ALUMINUM FRAME WITH PLYWOOD DECK Type A Hook*
2
7/16"
Type B Hook 1-5/16"
4
Type A part numbers listed. For Type B replace red 2 with a 4 in the part number
Part Number
Description
Weight
0054-216
19’ Wide x 7’ long - 75 psf capacity
32
0054-220-50
19’ Wide x 10’ long - 50 psf capacity
40
0054-220
19’ Wide x 10’ long - 75 psf capacity
46.5
0054-226
22’ Wide x 7’ long - 75 psf capacity
35
0054-230
22’ Wide x 10’ long - 50 psf capacity
44.5
0054-236
24’ Wide x 7’ long - 75 psf capacity
37
0054-240
24’ Wide x 10’ long - 50 psf capacity
50
0054-246
28’ Wide x 7’ long - 75 psf capacity
39
0054-250
28’ Wide x 10’ long - 50 psf capacity
54
0054-256
32’ Wide x 7’ long - 50 psf capacity
47
Other Tuf-N-Lite walkboeard sizes available. Contact factory.
TUF-N-LITE WALKBOARD REPLACEMENT PARTS
Aluminum hook replacement kit
Plywood deck replacement
Aluminum cross member
Part Number Description
Part Number
0054-007-07
7’ Aluminum rail 4 mem / punch
0090-0545
1/4 - 20 x 1S / tap screw
Description
0054-002-07
7’ Aluminum rail 3 mem / punch
0090-0987
3/16 drive rivet
0054-007-08
8’ Aluminum rail 4 mem / punch
0191-0019
Plywood for 0054-216
0054-002-08
8’ Aluminum rail 3 mem / punch
0191-0022
Plywood for 0054-220
0054-009-10
10’ Aluminum rail 4 mem / punch
0191-0049
Plywood for 0054-248
0054-102
Lock - swivel assembly, heavy duty A
0191-0050
Plywood for 0054-250
0054-101
Lock - swivel assembly, heavy duty B
0054-080
Conversion kit 2-bolt to 4 bolt
0054-130
Aluminum hook type A replacement kit
0054-131
Aluminum hook type B replacement kit
0054-018-05
Aluminum cross member for 19 walkboard
0054-018-08
Aluminum cross member for 28 walkboard
0054-018-09
Aluminum cross member for 32 walkboard
Other Tuf-N-Lite replacement parts available. Contact factory.
X-TRU-LITE WALKBOARD 7100 SERIES - ALUMINUM FRAME AND DECK Part Number
Description
0055-216
19 1/4” Wide x 7’ long - 75 psf capacity
Weight 32
0055-220
19 1/4” Wide x 10’ long - 75 psf capacity
40
Other X-Tru-Lite walkboard sizes available. Contact factory.
X-TRU-LITE WALKBOARD REPLACEMENT PARTS Part Number
Description
Weight
0055-216-3
End Support / 19” X-Tru-Lite
1
0082-0553
Aluminum hook repair kit - 1 hole
4
OUTRIGGER - specify tube size (5, 6, 7)
Page 8
Part Number (5, 6, 7)
Description
0048-2__
30” wide outrigger
Weight 14
Brackets / Hoist Arm / Outrigger / Putlogs SIDE AND END BRACKETS - specify tube size Part Number
Description
Capacity
Weight
SIDE BRACKETS
0039-165-5
0039-520-5
0039-621-5
0039-620-5
0039-620-__
20” Saddle hanger with tube end
500 lb
9
0039-624-__
24” Saddle hanger with tube end
500 lb
10
0039-630-__
30” Saddle hanger with tube end
500 lb
13
0039-165-__
20” - 30” Adjustable saddle hanger with tube end
500 lb
14
0039-124
12” Saddle hanger with plate end
500 lb
6
0039-621
21” Saddle hanger with plate end
500 lb
9
0039-720-__
20” Angle iron hanger - side hang-on with tube end
500 lb
9
0039-724-__
24” Angle iron hanger - side hang-on with tube end
500 lb
11.5
0039-730-__
30” Angle iron hanger - side hang-on with tube end
500 lb
13
0039-171-__
20” - 30” Adjustable angle iron hanger with tube end
500 lb
14
END BRACKETS 0039-520-__
20” End and side hang-on with tube end
500 lb
10.5
0039-524-__
24” End and side hang-on with tube end
500 lb
13
0039-530-__
30” End and side hang-on with tube end
500 lb
14
END GUARD RAIL FOR SIDE BRACKET 0012-266
0012-266
End guard rail for 20” to 30” side bracket
19
HOIST ARM - WELL WHEEL - TIE BRACE 0063-0344
0082-0103
0041-028
Part Number
Description
Weight
0041-028
Swivel head hoist arm
29
0082-0103
10” Well wheel
9.3
0063-0344
Scaffold tie brace
11
PUTLOGS Part Number Description Putlog
Trussed putlog
Weight
Part Number Description
Weight
0036-178
8 ‘ Putlog
24
0036-602
18’ Putlog - trussed
79
0036-180
10’ putlog
30
0036-603
20’ Putlog - trussed
92
0036-182
12’ Putlog
36
0036-604
22’ Putlog - trussed
101
0036-600
14’ Putlog - trussed
47
0036-605
24’ Putlog - trussed
111
0036-601
16’ Putlog - trussed
70
0036-606
26’ Putlog - trussed
118
Other putlog sizes available. Contact factory.
PUTLOG ACCESSORIES 0037-22
0036-040 0036-042 0036-043
0061-11 0061-12 0061-10
0037-16
Part Number
Description
0037-16
Putlog angle hanger
0061-11
Offset insert saddle (tube size 5)
3
0061-12
Offset insert saddle (tube size 6)
3
0061-10
Offset insert saddle (tube size 7)
3
0061-29
Insert saddle (tube size 5)
3
0061-06
Insert saddle (tube size 6)
3
0061-23
Insert saddle (tube size 7)
3
0037-22
Putlog support 8’ long with clamps
20
0036-040
Putlog spreader - 5’ frame sp (tube size 6)
24
0036-042
Putlog spreader - 5’ frame sp (tube size 5)
14
0036-043
Putlog spreader - 7’ frame sp (tube size 5)
24
0061-29 0061-06 Other putlog accessories available. Contract factory.
All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.
Weight 3.5
Page 9
Clamps / Brackets / Replacement Parts / Stair Tower Components DROPPED FORGED CLAMPS 0069-0094 0069-0117
0069-0095 0069-0118
Part Number
Description
0069-0095
Swivel clamp with “Eye” bolt - fits 1.625”, 1.69”, 1.9” tube diamater
Weight 3
0069-0094
Rigid clamp with “Eye” bolt - fits 1.625”, 1.69”, 1.9” tube diamater
3
0069-0118
Swivel clamp with “Eye” bolt - fits 1.69” and 1.9” tube diamater
3
0069-0117
Rigid clamp with “Eye” bolt - fits 1.69” and 1.9” tube diamater
3
BRACKETS AND CLAMPS
0069-0015
0069-0043
0069-0013
0069-0026
0069-0017
0069-0070 0069-0057
Part Number
Description
Weight
0069-0017
Parallel tube clamp
1.5
0069-0016
Bracket for hole or notched brace
.5
0069-0026
Bracket for hole brace
.5
0069-0013
Clamp for notched brace
1.5
0069-0043
Clamp for hole brace
1.5
0069-0070
B-Lock clamp (tube size 5)
.5
0069-0057
B-Lock clamp (tube size 6, 7)
.5
REPLACEMENT PARTS 0064-0783
0068-004
0066-0006
0068-008
0067-0005
0068-042/1
0067-0739 0067-0046
0068-095 0090-0517
Part Number Description
Part Number Desciption
0064-0783
Half outrigger clamp
0068-008
0066-0006
Putlog clamp hook
0068-042/1
Brace rivet with 3 washers
0067-0005
Gooser brace slide
0068-042/50
Package 50 brace rivets with 150 washers
0067-0039
Leveling nut (1 7/16”)
0068-095
U-Bolt only - Putlog angle hanger 0037-16
0067-0046
Leveling nut (1 1/4”)
0090-0517
Thumb screw - 3/8” diamater x 1 1/4” long
0068-004
1/2” set screw
Lever tail nut 5” long
BRACE LOCK PARTS
0064-0604
0068-009
0068-013
Part Number Description
Part Number Desciption
0068-123A
C-Lock with stud pin
0008-042
F-Lock complete
0068-123
C-Lock stud
0008-048
U-Lock complete
0064-0604
C-Lock slide
0068-009
J-Lock stud 1/2”
0008-022-4/50
C-Lock washer
0066-0044
J-Lock pin 3/8” x 3/4”
0090-0311/50
C-Lock roll pin
0068-013
J-Lock wing nut 1/2”
0008-044
T-Lock complete
TUF-N-LITE HINGED LADDER BOARD - ALUMINUM FRAME, PLYWOOD DECK, ATTACHED LADDER Part Number
Description
Weight
0054-125-07
28” Wide x 7’ long - 75 psf capacity
69
0054-125-08
28” Wide x 8’ long - 50 psf capacity
75
0054-125-10
28” Wide x 10’ long - 50 psf capacity
81
STAIR TOWER COMPONENTS Part Number Description
Part Number Description
0042-019
Stair platform rest (tube size 5)
0043-185
Outside handrail (top section)
0042-027
Stair platform rest (tube size 6)
0042-175
Inside handrail (top section)
0042-035
Stair platform rest (tube size 7)
0042-221
24” Wide stair section 6’ 5”
0042-047
Open frame safety guard
0042-022
24” Wide stair section 6’ 6”
0042-094
Outside handrail
0042-223
24” wide stair section 6’ 7”
0042-093
Inside handrail
0044-052
Intermediate catwalk 28” wide x 7’ long with guardrail
0044-054
Hinged platform 28” wide x 7’ long expanded steel
0044-235
28” Wide x 7’ Long expanded steel catwalk - 75 psf capacity
BilJax offers a heavy duty stair tower for worker access to buildings, bridges, observation towers, or renovation done inside or outside. The stairs can also be used for access in a scaffold set-up. Page 10
Access Ladder / Climbing Ladder ACCESS LADDER SYSTEM (see below image)
0042-130
0042-126 Top hinged platform
Part Number
Description
0042-126
6’ Access ladder (use with 6’ 6” high frame)
Weight
0042-130
6’ Handrails (pair)
10.5
0042-129
Platform rest (tube size 5) (2 required at 1st tier only)
7.5
0042-128
Platform rest (tube size 6, 7) (2 Required at 1st tier only)
8
0054-346
Top hinged platform 28” x 7’
43
0054-348
Top hinged platform 28” x 8’
49
0054-350
Top hinged platform 28” x 10’
55
37
CLIMBING LADDER - TUBULAR TYPE (see below image)
0063-0074 0063-0073 0004-0376 0004-0377
Part Number
Description
Weight
0004-0377
6’ Top section
0004-0375
6’ Ladder section
17.5
0004-0376
3’ Ladder section
9.2
0063-0074
Support bracket (tube size 5)
5.5
0063-0073
Support bracket (tube size 6, 7)
5.5
19
CANOPY TOP / WEATHER PROTECTION CLIP (see below image) Part Number
Description
0071-021
Canopy top with adjustable extension - 5’ W x 1’ H (tube size 6)
Weight 27
0071-022
Canopy Top with adjustable extension - 5’ W x 1’ H (tube size 7)
27
0071-024
Canopy top with adjustable extension - 5’ W x 1’ H (tube size 5)
27
0082-0228
Weather protection clips 8” L 9 (qty. 100)
16
ADDITIONAL ILLUSTRATIONS ACCESS LADDER SYSTEM
CLIMBING LADDER TUBULAR TYPE
CANOPY TOP WEATHER PROTECTION CLIP Maximum 10’ 6’
Up to 4’
All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.
Page 11
Pro-Jax Scaffold Packages / Guard Rail
PRO-JAX UTILITY SCAFFOLD PACKAGES WITH PLYWOOD DECK WALKBOARDS Part Number
0127-006-0 Single Unit
0127-006-1 Single Unit w/ Guard Rail
0127-006-2 2 Single Units w/ Guard Rail & 18” Wide Outriggers
Description Length
Platform Ht Range
0127-006-0
6’
0127-006-1
6’
0127-006-2 0127-006-3 0127-008-0
Includes
Weight
Guard Rails
Outriggers
2’ - 4’
No
No
147
2’ - 6’
Yes
No
240
6’
2’ -11.5’
Yes
Yes
430
6’
2’ - 17’
Yes
Yes
538
8’
2’ - 4’
No
No
173
0127-008-1
8
2’ - 6’
Yes
No
279
0127-008-2
8’
2’ - 11.5’
Yes
Yes
490
0127-008-3
8’
2’ - 17’
Yes
Yes
609
0127-010-0
10’
2’ - 4’
No
No
200
0127-010-1
10’
2’ - 6’
Yes
No
316
0127-010-2
10’
2’ - 11.5’
Yes
Yes
525
0127-010-3
10’
2’ - 17’
Yes
Yes
645
PRO-JAX UTILITY SCAFFOLD ADDITIONAL HEIGHT PACKAGES Part Number
Description
0127-007-3
6’ Length x 39” height unit
Weight 75
0127-007-5
6’ Length x 65” height unit
95
0127-009-3
8’ Length x 39” height unit
93
0127-009-5
8’ Length x 65” height unit
103
0127-011-3
10’ Length x 39” height unit
97
0127-011-5
10’ Length x 65” height unit
123
PRO-JAX GUARD RAIL PACKAGES, OUTRIGGER PACKAGES, AND LEVELING EXTENSION 0127-149-08
0127-138
Page 12
0127-150-18
Part Number
Description
Weight
0127-149-06
6’ Complete guard rail package (2 pieces)
81.5
0127-149-08
8’ Complete guard rail package (2 pieces)
98
0127-149-10
10’ Complete guard rail package (2 pieces)
115
0127-150-18
18” Wide outrigger package (4 pieces)
39
0127-150-24
24” Wide outrigger package (4 pieces)
44
0127-138
Leveling extension
Pro-Jax Replacement Parts & Components / Handy Roll PRO-JAX REPLACEMENT PARTS Part Number
Description
0063-0377
L-Pin replacement kit for platform arm brace
Weight .25
0063-0418
Wind latch replacement kit
.25
0063-0605
Saf-T-Lok replacement kit
.40
PRO-JAX COMPONENTS
0127-102
0127-101
0127-108-06
0127-113
0127-149-06
Part Number
Description
Weight
0127-102
39” High ladder frame
15
0127-101
65” ladder frame
25
0127-147
Base extension unit
29
0127-163-06
6’ Platform arm brace
21
0127-163-08
8’ Platform arm brace
26
0127-163-10
10’ Platform arm brace
32
0127-108-06
6’ Plywood deck
29
0127-108-08
8’ Plywood deck
40
0127-108-10
10’ Plywood deck
52
0127-141-06
6’ Top hinged plywood deck
47
0127-141-08
8’ Top hinged plywood deck
60
0127-141-10
10’ Top hinged plywood deck
73
0127-113
6’ Expanded metal deck
36
0127-114
8’ Expanded metal deck
48
0127-115
10’ Explanded metal deck
60
0127-106-06
6’ Combination guard panel
35.5
0127-106-08
8’ Combination guard panel
42
0127-106-10
10’ Combination guard panel
48
0127-105-18
18” Wide outrigger
8
0127-105-24
24” Wide outrigger
11
0127-118
48” Wide outrigger
26
0127-136-06
6’ Intermediate guard rail
20
0127-136-08
8’ Intermediate guard rail
24
0127-136-10
10’ Intermediate guard rail
28
0127-138
Adjustable leg with rubber pad
0026-835
5” Caster - 250 lb capacity with 2” snap pin (trailing edge brake lock)
0026-952
8” Caster - 500 lb capacity with 2” snap pin - P5
0127-150-18
0127-163-06
3
0026-835
4.75 10
0026-952
HANDY ROLL SCAFFOLDING 4-CASTER UNITS Part Number
Description
0063-0435-34
3’ Handy roll scaffold 4-caster unit with steel platforms - 24” wide x 48” long x 39” high
82
0063-0435-44
4’ Handy roll scaffold 4-caster unit with steel platforms - 24” wide x 48” long x 51” high
87
0063-0435-54
5’ Handy roll scaffold 4-caster unit with steel platforms - 27” wide x 64” long x 63” high
106
All images are for illustration only. Haulotte Group | BilJax reserves the right to modify specifications without notice. Follow all applicable ANSI and OSHA codes/regulations when using this equipment. Do not use in ares where user can come in contact with live power.
Weight
Page 13
Drywall Cart / Drywall Lift DRYWALL CART
0063-0575-11YE
Part Number
Description
Capacity
Weight
0063-0573-01YE
Model DC 3000 LD, light duty with plastic casters (2 swivel - 2 rigid) - 23” wide x 50” long x 47” high
3000
84
0063-0574-11YE
Model DC 3000 MD, medium duty with steel casters (2 swivel - 2 rigid) - 23” wide x 49” long x 47” high
3000
104
0063-0575-11YE
Model DC 3000 EX, heavy duty with steel casters (2 swivel - 2 rigid) - 28” wide x 50” long x 47” high
3000
137
Part Number
Description
Capacity
Weight
0063-0547
Model DL 100 Steel - 5’ to 10’ lift adjustment
200
104
0063-0580
Model DL 125 Steel - 5’ to 12’ lift adjustment
200
125
0063-0595
Model DL 150 Steel - 5’ to 15’ lift adjustment
160
141
DRYWALL LIFT
0063-0580
Scaffold Safety Guidelines - recommended by Scaffolding, Shoring & Forming Institute It shall be the responsibility of all employers and employees to read and comply with the following common sense guidelines which are designed to promote safety in the erecting and dismantling of scaffolds. These guidelines do not purport to be all-inclusive nor to supplant or replace other additional safety and precautionary measures to cover usual or unusual conditions. Local, State or Federal statute or regulations shall supersede these guidelines if there is a conflict and it is the responsibility of each employee to comply. I. II. III. IV. V. VI. VII. VIII. IX. X.
GENERAL GUIDELINES
POST THESE SCAFFOLDING SAFETY GUIDELINES in a conspicuous place and be sure that all persons who erect, dismantle or use scaffolding are aware of them. FOLLOW ALL STATE, LOCAL AND FEDERAL CODES, ORDINANCES AND REGULATIONS pertaining to scaffolding because they may be more restrictive. For example, height or width requirements may vary. SURVEY THE JOB SITE—A survey shall be made of the job site for hazards, such as untampered earth fills, ditches, debris, high tension wires, unguarded openings, and other hazardous conditions created by other trades. These conditions shall be corrected or avoided as noted in the following sections. INSPECT ALL EQUIPMENT BEFORE USING—Never use any equipment that is damaged or defective in any way. KEEP ALL EQUIPMENT IN GOOD REPAIR—Avoid using corroded equipment—the strength of corroded equipment is not known. INSPECT ERECTED SCAFFOLDS DAILY—or at the beginning of every shift to be sure that they are maintained in safe condition. NEVER USE EQUIPMENT FOR PURPOSES OR IN WAYS FOR WHICH IT WAS NOT INTENDED. REPORT ANY UNSAFE CONDITION. NEVER TAKE CHANCES—Do not work on scaffolds if your physical condition is such that you feel dizzy or unsteady in any way. WORKING UNDER THE INFLUENCE OF ALCOHOL OR ILLEGAL DRUGS IS STRICTLY PROHIBITED. CONSULT YOUR SCAFFOLDING SUPPLIER—NEVER TAKE CHANCES—Consult manuals and instructions provided by the supplier; scaffolding is his business.
GUIDELINES FOR ERECTION AND USE OF SCAFFOLDS
A. PROVIDE ADEQUATE SILLS for scaffold posts and use base plates. B. USE ADJUSTING SCREWS or other approved conditions. C. PLUMB AND LEVEL ALL SCAFFOLDS as the erection proceeds. Do not force braces to fit—level the scaffold until proper fit can be made easily. D. BRACING. Each frame or panel shall be braced by horizontal bracing, cross bracing, diagonal bracing or any combination thereof for securing vertical members together laterally. All brace connections shall be made secure, in accordance with manufacturers’ recommendations. E. DO NOT CLIMB CROSS BRACES. Use only an access (climbing) ladder, access steps, frame designed to be climbed or equivalent safe access to scaffold. F. TIE RUNNING SCAFFOLD TO WALL or structure when the height exceeds* four (4) times the minimum scaffold base dimension. The first vertical and longitudinal tie shall be placed at this point. Vertical ties shall be repeated at intervals not greater than 26 feet. Longitudinal ties shall be placed at each end and at intervals not greater than 30 feet. Ties must prevent the scaffold from tipping into or away from the wall or structure. G. WHEN SCAFFOLDS ARE TO BE PARTIALLY OR FULLY ENCLOSED, specific precautions must be taken to assure frequency and adequacy of ties attaching the scaffolding to the building due to increased load conditions resulting from effects of wind and weather. The scaffolding components to which the ties are attached must also be checked for additional loads. H. WHEN FREE STANDING SCAFFOLD TOWERS exceed* four times their minimum base dimension vertically, they must be restrained from tipping. I. DO NOT ERECT SCAFFOLDS NEAR ELECTRICAL POWER LINES UNLESS PROPER PRECAUTIONS ARE TAKEN. Consult the power service company for advice. J. DO NOT USE ladders or makeshift devices on top of scaffolds to increase the height. K. DO NOT EXCEED MANUFACTURERS’ RECOMMENDED LOAD RATING. L. EQUIP AND MAINTAIN ALL PLATFORMS with proper guardrails, midrails, and toeboards along all open sides and ends of scaffold platforms. M. ALL BRACKETS shall be seated correctly with side brackets parallel to the frames and end brackets at 90 degrees to the frames. Brackets shall not be bent or twisted from normal position. Brackets (except mobile brackets designed to carry materials) are to be used as work platforms only and shall not be used for storage of material or equipment. When brackets are used, the scaffold shall be tied to the structure or otherwise restrained to prevent tipping. N. ALL SCAFFOLDING ACCESSORIES shall be used and installed in accordance with the manufacturers’ recommended procedure. Accessories shall not be altered in the field. Scaffolds, frames and their components of various manufacturers shall not be intermixed. O. FOR PLANKING, THE FOLLOWING GUIDELINES APPLY: 1. Use only lumber that is properly inspected and graded as scaffold plank. 2. Planking shall have at least 12 inches of overlap and extend 6 inches beyond center of support, or, be cleated at both ends to prevent sliding off supports.
Page 14
3.
P.
3.
Q.
R.
S.
Fabricated scaffold planks and platforms, unless created or restrained by hooks, shall extend over their end supports not less than 6 inches nor more than 12 inches. 4. Secure plank to scaffold when necessary. FOR ROLLING SCAFFOLDS THE FOLLOWING ADDITIONAL GUIDELINES APPLY. 1. CASTERS WITH PLAIN STEMS shall be attached to the panel or adjustment screw by pins or other suitable means. 2. DO NOT EXTEND ADJUSTING SCREWS ON ROLLING SCAFFOLDS MORE THAN 12 INCHES. WHEELS OR CASTERS shall be provided with a locking device and kept locked during erection and dismantling or any time scaffolds are not being moved. 4. SECURE OR REMOVE ALL MATERIAL AND EQUIPMENT from platform before moving scaffold. 5. USE HORIZONTAL DIAGONAL BRACING near the bottom and at 20 foot intervals measured from the rolling surface. 6. DO NOT USE brackets or other platform extensions without consideration of overturning effect. 7. THE HEIGHT OF A ROLLING SCAFFOLD excluding its uppermost guardrails, must not exceed* four times its smallest base dimension unless it is stabilized by an engineered counterweight system or some other equivalent means. 8. CLEAT OR SECURE ALL PLANKS. 9. DO NOT ATTEMPT TO MOVE A ROLLING SCAFFOLD WITHOUT SUFFICIENT HELP—watch out for holes in floor and overhead obstructions—stabilize against tipping. 10. DO NOT RIDE ROLLING SCAFFOLDS. 11. JOINTS shall be restrained from separation. FOR “PUTLOGS” AND “TRUSSES” the following additional guidelines apply. 1. DO NOT CANTILEVER OR EXTEND PUTLOGS/TRUSSES as side brackets without thorough consideration for loads to be applied. 2. PUTLOGS/TRUSSES SHOULD BE EXTENDED AT LEAST 6 inches beyond point of support. 3. PLACE RECOMMENDED BRACING BETWEEN PUTLOGS/TRUSSES when the span of putlog/truss is more than 12 feet. WHEN DISMANTLING SCAFFOLDING THE FOLLOWING ADDITIONAL GUIDELINES APPLY: 1. CHECK TO SEE IF SCAFFOLDING HAS BEEN STRUCTURALLY ALTERED in any way which would make it unsafe, and if so, reconstruct where necessary before commencing with dismantling procedures. 2. VISUALLY INSPECT PLANK prior to dismantling to be sure that they are safe to work on. 3. COMPONENTS SHOULD BE LOWERED as soon as dismantled in safe manner so as to protect personnel below. 4. DO NOT ACCUMULATE EXCESS COMPONENTS OR EQUIPMENT on the level being dismantled. 5. DISMANTLED EQUIPMENT should be stockpiled in an orderly manner. FOLLOW ERECTION PROCEDURES AND USE MANUALS.
SCAFFOLD FRAME MEASUREMENT CHARTS These facts are needed whenever you are not sure that the frame is a BilJax brand product. If you do not have previous experience with the frame ordered, or if you do not have the item number, answer the below questions and provide them with your order.
Step frame
Center access frame
Open frame
Ladder frame
A. Specify Rotation of Pin Holes 1. 900 or 450 top & bottom 900 Standard B. Width of Frame Center to Center 1. To get this measurement, place tape outside to inside of leg tube. C. Frame Height 1. Measure overall top to bottom 2. DO NOT include insert (stacking pin) in measurement D. Lock Spacing 1. Measure distance from top of top lock pin to top of bottom lock pin 2. When a lock had two pins, use the lower pin of both locks E. Lock Location 1. Measure between top of leg and the center of the top lock pin 2. In case of a two pin lock, use the lower pin F. Tube Size of Leg (diameter) 1. Measure leg outside to outside 1-1/2”, 1-5/8”, 1-11/16” standard sizes