SECTION G:
PARKING PRK10 SERIES
PARKING IDENTIFICATION
PRK20 SERIES PARKING IDENTIFICATION: W10E KSK10 SERIES
KIOSK INFORMATION
Some parking signs were implemented prior to the completion of this Universitywide Standard. These signs have been documented and are represented in this section. There are some parking signs that are unique to the Health Science campus and can be found in Section J of this manual.
This Page Intentionally Left Blank
2G.2
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SUB-SECTION SECTION G:
PRK10 SERIES
PRK10 Series – Parking Identification PRK10 Series Overview Recommended sign type configurations shown. Additional module configurations must be approved by Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
Sign Selection Process Below are the following steps for selecting the correct parking identification for your needs. Lot ID
A. Verify the parking area/lot name, street associated with the lot and regulatory information.
ADDRESS
Permit Required at all Times Visitors: See Parking Kiosk for Permit
B. Analyze the location, mounting detail and space availability.
PRK11
Parking Lot ID PARKING ADDRESS
Permit Required at all Times Visitors: See Parking Kiosk for Permit
PRK12
C. Determine message lengths and character (letter) counts for each message. D. Select from the typical module widths based on previous steps. See graphic layout pages for sample typographic layouts. E. Review graphic dont’s to ensure proper selection.
PRK10 SERIES: LOT ID: Up to 7 characters ADDRESS: Up to 12 characters for street name
PRK11
MAX. COPY LENGTH: Max. Length 1’-3 3/4” LOT ID: Up to 12 characters ADDRESS: Up to 24 characters for street name
PRK12
MAX. COPY LENGTH: Max. Length 2’-3 3/4”
? Questions? Please contact xxxxx
2G.4
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK11
GRAPHIC LAYOUT
PARKING IDENTIFICATION
ELEVATION
Guidelines • To identify parking areas
using the lot name and street associated with the lot.
a C D E F
Lot 9
BERGEN STREET
Permit Required At All Times Visitors See Parking Kiosk For Permit
• Reinforce the brand equity
in the built environment with accent color & Rutgers logotype header. • Use as a single-sided or
double-sided sign. Message standards apply to both sides of sign.
27’’
• Locate freestanding parking
G B
identification signs at parking lot/area entrances or driveways. Only one lot should be identified per sign.
Configuration 1
• Do not rearrange panel order. H
Full length filler panels are used for single sided signs only. (not shown)
I
Stop panel below grade line. (not shown)
• The bottom panel is designat-
CONFIGURATIONS
ed for parking information only (i.e. A parking pass is needed from 8am-5pm) • Non-motorized parking areas
may be identified. See graphic layouts for correct usage.
PART COUNTS CONFIGURATION 1:
Helpful Hints
*
*
SINGLE SIDED
DOUBLE SIDED
A
POST CAP
2
2
B
SIGN POST
2
2
C
PNL.1
1
2
D
FP_1
4
8
E
PNL.2
1
2
F
PNL.3
1
2
G
FP_2
2
4
H
FP_3
2
0
I
FP_S
4
4
• Keep in mind the intuitive
path of the user when locating and specifying exterior parking identification signs. • Use only standard and ap-
proved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed. For specification and ordering purposes, contact EMS Delaware; 231 Executive Drive Suite 11 Newark, DE 19702 USA Toll Free: 800-863-1496 Local Phone: 302-391-1370 Fax: 302-391-1371 Website: www.EasternMetal.com Email:
[email protected]
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.5
PARTS
PRK11
ELEVATION DETAIL
PARKING IDENTIFICATION
GRAPHIC LAYOUT 3'-3 1/2"
Specifications
4"
2'-7 1/2"
CEF J K H B H A CEF
4"
6" 4"
1'-2"
1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
4"
A Post Cap
B Sign Post
2'-6"- graphic panel
3/4"
Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. *See post extrusion spec. information on Parts sheet.
3/4"
PRK11 3/4” = 1’-0”
Back ElevationSingle side Sign
Plan ElevationSingle side Sign (double side panels shown dashed)
C PNL.1
1" 4"
C D
Lot ID
1'-4"
D FP_1
E
STREET NAME
D F
1"
1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
G FP_2 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
Regulatory Permit Information Two Line Message
2'-3"
B G J K grade line
2" Min.
F PNL.3
4'-9"
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
8"
E PNL.2
2G.6
A
1/8"
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P1. *Use one panel only for . single sided sign.
I
PRK11 3/4” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK11
GRAPHIC LAYOUT
PARKING IDENTIFICATION
ELEVATION
Specifications
H FP_3 1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
I FP_S 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
J Concrete Footer / Pad Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be Below grade and landscaping, by others, where necessary.
K Concrete Sidewalk
This Page Intentionally Left Blank
S E C T I O N G : PA R K I N G
If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and re-pour sidewalk square.
2G.7
PARTS
PRK11
ELEVATION DETAIL
PARKING IDENTIFICATION
GRAPHIC LAYOUT
Specifications
A Post Cap 1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
A
B Sign Post Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. *See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P1. *Use one panel only for . single sided sign.
N O
becomes sign panel
C
H D
N O
D FP_1 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
E
E PNL.2 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
F PNL.3 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
F
B G
Component Parts / Assembly Finished Sign
G FP_2 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
2G.8
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
3 1/4" 1 3/4"
1/8" typ.
G B
GRAPHIC LAYOUT
PARKING IDENTIFICATION
CEF 7/8"
O
Specifications
H FP_3
1/8"
1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
N
O
C E F
1/4"
N
7/8"
1/4" panel extrusion variessee elevations for height dimensions
1/8"
2" panel height variessee elevations for height dimensions
6"
PRK11
1 1/8"
4 1/4"
1/8" typ.
DETAIL
3/4"
7/8"
3/4"
ELEVATION
Panel Detail no scale
J Concrete Footer / Pad Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be Below grade and landscaping, by others, where necessary.
k Concrete Sidewalk
3'-2" panel length
If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and re-pour sidewalk square.
Partial Horizontal Section 6” = 1’-0”
L Expansion Joint To accommodate concrete expansion and contraction.
K
M Sand
L J
Compacted sand for condensation drainage per engineering requirements. Plan Elevation at Sidewalk
N Attachment Bracket 4" above finished grade
no scale
B grade line
grade line
Rutgers owned custom extruded bracket cut to match height of aluminum plate. Permanently mount to back of plate. *See post extrusion spec. information on Parts sheet.
O Sign Panel Plate 1/8” Thk. aluminum plate cut to dimensions shown in elevations.
K L
J M Vertical Section: Concrete Footer
Vertical Section: Concrete Footer
no scale
no scale
at concrete sidewalk condition
at earth / grass condition
DETAIL S E C T I O N G : PA R K I N G
2G.9
PARTS
PRK11
ELEVATION DETAIL
PARKING IDENTIFICATION
GRAPHIC LAYOUT
Specifications
A RU_Logotype.eps 1 1/2” T-cap height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
B Copy 3” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
C Copy
A 1 1/2"
6 1/2” Diameter. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2. Weed out P from black vinyl background; to have background panel color.
PNL.1 1” = 1’-0”
3"
Lot ID align
C L
1” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
1'-3 3/4"- maximum copy length
ST NAME 1-LINE
PNL.2 (max. message)
D B 2 5/8"
E Copy
5"
3"
7 1/2"
6 1/4"
1 1/2"
D Parking_Symbol.eps
3" 2 5/8"
1 1/2” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
C
1” = 1’-0”
align
1"
1 7/8" 3 1/2"
3"
2'-0"- maximum copy length
Regulatory Permit Information Two Line Message
E
PNL.3 (max. message) 1” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.10
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK11
GRAPHIC LAYOUT
PARKING IDENTIFICATION
Lot ID
2- Line ID Message
2 5/8"
STREET NAME TWO LINE
PNL.2- Variation
3/4”= 1’-0”
3/4”= 1’-0” “Bicycle Parking” is the only approved message for this panel layout.
Regulatory Permit Info. 1-Line Message
C L
PNL.2- Variation
5"
ELEVATION
PNL.3- Variation
3"
3/4”= 1’-0”
Regulatory Permit Information Up to 3-Lines
PNL.3- Variation 3/4”= 1’-0”
GRAPHIC LAYOUTS
Lot 54 HOES LANE
Lee Hall Parking Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT use this layout to identify parking lots or garages.
Lot 11, 12 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT identify more than one lot per parking identification sign.
Lot 54 Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT exclude the street name from the parking identification.
Lot 55 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
No more than ONE parking message panel.
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Lot 54 HOES LANE
Lot 54 HOES LANE
Park Here for Lot 54, 55, 56, 56A, 57, 58, 58A
ONLY permit information is to appear on PNL.6.
Do NOT rearrange panel order or exclude panels.
GRAPHIC ELEVATION DONT’S S E C T I O N G : PA R K I N G
2G.11
This Page Intentionally Left Blank
2G.12
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK12
GRAPHIC LAYOUT
PARKING IDENTIFICATION
ELEVATION
Guidelines • To identify parking areas
using the lot name and street associated with the lot.
a C D E F
Message Message
Message Message
• Reinforce the brand equity
in the built environment with accent color & Rutgers logotype header. • Use as a single-sided or
double-sided sign. Message standards apply to both sides of sign.
27’’
• Locate freestanding parking
G B
identification signs at parking lot/area entrances or driveways. Only one lot should be identified per sign.
Configuration 1
• Do not rearrange panel order. H
Full length filler panels are used for single sided signs only. (not shown)
I
Stop panel below grade line. (not shown)
• The bottom panel is designat-
CONFIGURATIONS
ed for parking information only (i.e. A parking pass is needed from 8am-5pm) • Non-motorized parking areas
may be identified. See graphic layouts for correct usage.
PART COUNTS CONFIGURATION 1:
Helpful Hints
*
*
SINGLE SIDED
DOUBLE SIDED
A
POST CAP
2
2
B
SIGN POST
2
2
C
PNL.1
1
2
D
FP_1
4
8
E
PNL.2
1
2
F
PNL.3
1
2
G
FP_2
2
4
H
FP_3
2
0
I
FP_S
4
4
• Keep in mind the intuitive
path of the user when locating and specifying exterior parking identification signs. • Use only standard and ap-
proved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed. For specification and ordering purposes, contact EMS Delaware; 231 Executive Drive Suite 11 Newark, DE 19702 USA Toll Free: 800-863-1496 Local Phone: 302-391-1370 Fax: 302-391-1371 Website: www.EasternMetal.com Email:
[email protected]
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.13
PARTS
PRK12 PARKING IDENTIFICATION
ELEVATION DETAIL GRAPHIC LAYOUT 4'-3 1/2"
Specifications
4"
3'-7 1/2"
4"
6" 4"
1'-2"
1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
4"
A Post Cap
B Sign Post
3'-6"- graphic panel
3/4"
Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. *See post extrusion spec. information on Parts sheet.
CEF J K H B A CEF
3/4"
PRK12 3/4” = 1’-0”
Plan ElevationSingle side Sign (double side panels shown dashed)
C PNL.4
1" 4"
C D
Parking Lot ID
1'-4"
D FP_1
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
G FP_2 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
Regulatory Permit Information Two Line Message
D F
2'-3"
B G J K grade line
2" Min.
F PNL.6
4'-9"
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
8"
E PNL.5
E
STREET NAME
1"
1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
2G.14
A
1/8"
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P1. *Use one panel only for . single sided sign.
I
PRK12 3/4” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK12
GRAPHIC LAYOUT
PARKING IDENTIFICATION
ELEVATION
Specifications
H FP_3 1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
H
I FP_S 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
J Concrete Footer / Pad
Back ElevationSingle side Sign
Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be below grade and landscaping, by others, where necessary.
K Concrete Sidewalk If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and re-pour sidewalk square.
ELEVATION S E C T I O N G : PA R K I N G
2G.15
PARTS
PRK12 PARKING IDENTIFICATION
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A Post Cap 1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
A
B Sign Post Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. *See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P1. *Use one panel only for . single sided sign.
N O
becomes sign panel
C
H D
N O
D FP_1 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
E
E PNL.2 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
F PNL.3 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
F
B G
Component Parts / Assembly Finished Sign
G FP_2 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
2G.16
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
3 1/4" 1 3/4"
1/8" typ.
G B
GRAPHIC LAYOUT
PARKING IDENTIFICATION
CEF 7/8"
O
Specifications
H FP_3
1/8"
1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
N
O
C E F
1/4"
N
7/8"
1/4" panel extrusion variessee elevations for height dimensions
1/8"
2" panel height variessee elevations for height dimensions
6"
PRK12
1 1/8"
4 1/4"
1/8" typ.
DETAIL
3/4"
7/8"
3/4"
ELEVATION
Panel Detail no scale
J Concrete Footer / Pad Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be below grade and landscaping, by others, where necessary.
k Concrete Sidewalk
3'-2" panel length
If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and re-pour sidewalk square.
Partial Horizontal Section 6” = 1’-0”
L Expansion Joint
K
To accommodate concrete expansion and contraction.
L J
M Sand Compacted sand for condensation drainage per engineering requirements.
Plan Elevation at Sidewalk no scale
4" above finished grade
N Attachment Bracket B
grade line
grade line
Rutgers owned custom extruded bracket cut to match height of aluminum plate. Permanently mount to back of plate. *See post extrusion spec. information on Parts sheet.
O Sign Panel Plate 1/8” Thk. aluminum plate cut to dimensions shown in elevations.
K L
J M Vertical Section: Concrete Footer
Vertical Section: Concrete Footer
no scale
no scale
at concrete sidewalk condition
at earth / grass condition
DETAIL S E C T I O N G : PA R K I N G
2G.17
PARTS
PRK12 PARKING IDENTIFICATION
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A RU_Logotype.eps 1 1/2” T-cap height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
B Copy 3” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
C Copy
A 1 1/2"
6 1/2” Diameter. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2. Weed out P from black vinyl background; to have background panel color.
PNL.4 1” = 1’-0”
Lot ID align
C L
1” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
2'-3 3/4"- maximum copy length
STREET NAME 1-LINE
PNL.5 (max. message)
3"
D B 2 5/8"
E Copy
5"
3"
7 1/2"
6 1/4"
1 1/2"
D Parking_Symbol.eps
3" 2 5/8"
1 1/2” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
C
1” = 1’-0”
align
1"
1 7/8" 3 1/2"
3"
2'-0"- maximum copy length
Regulatory Permit Information Two Line Message
E
PNL.6 (max. message) 1” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.18
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK12
GRAPHIC LAYOUT
PARKING IDENTIFICATION
ELEVATION
Lot ID
Specifications 2 5/8"
STREET NAME TWO LINE
PNL.5- Variation 3/4”= 1’-0”
5"
2- Line ID Message PNL.5- Variation
Regulatory Permit Info. 1-Line Message
C L
3/4”= 1’-0” “Bicycle Parking” is the only approved message for this panel layout.
PNL.6- Variation
2 5/8"
3/4”= 1’-0”
Regulatory Permit Information Up to 3-Lines
PNL.6- Variation 3/4”= 1’-0”
GRAPHIC LAYOUTS
Lot 54
FRELINGHUYSEN ROAD
Lot 54, Lot 55
Lot 54
FRELINGHUYSEN ROAD
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT identify more than one lot per parking identification sign.
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT exclude the street name from the parking identification.
Lot 55
FRELINGHUYSEN ROAD
Permit Required at all Times Visitors: See Parking Kiosk for Permit
No more than ONE parking message panel.
Lot 54
Permit Required at all Times Visitors: See Parking Kiosk for Permit
FRELINGHUYSEN ROAD
Lot 54 Park Here for Lot 54, 55, 56, 56A, 57, 58, 58A
ONLY permit information is to appear on PNL.6.
FRELINGHUYSEN ROAD
Do NOT rearrange panel order or exclude panels.
GRAPHIC ELEVATION DONT’S S E C T I O N G : PA R K I N G
2G.19
This Page Intentionally Left Blank
2G.20
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SUB-SECTION SECTION G:
PRK20
PRK20 Series – Parking Identification: W10E PRK20 Series Overview Recommended sign type configurations shown. Additional module configurations must be approved by Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
Lot ID
Lot ID
Regulatory Permit Information Two Line Message
Regulatory Permit Information Two Line Message
Sign Selection Process Below are the following steps for selecting the correct parking identification for your needs.
ST. NAME 1-LINE
PRK21
LONG STREET NAME
PRK22
A. Verify the parking area/lot name, street associated with the lot and regulatory information. B. Analyze the location, mounting detail and space availability. C. Determine message lengths and character (letter) counts for each message. D. Select from the typical module widths based on previous steps. See graphic layout pages for sample typographic layouts. E. Review graphic dont’s to ensure proper selection.
PRK20 SERIES: LOT ID: Up to 7 characters ADDRESS: Up to 12 characters for street name
PRK21
MAX. COPY LENGTH: Max. Length 1’-3 3/4” LOT ID: Up to 12 characters ADDRESS: Up to 24 characters for street name
PRK22
MAX. COPY LENGTH: Max. Length 2’-3 3/4”
? Questions? Please contact xxxxx
2G.22
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK21
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
Guidelines • To identify parking areas
using the lot name and street associated with the lot. • Reinforce the brand equity
Lot ID
in the built environment with accent color & Rutgers logotype header.
A
• Use as a single-sided or
double-sided sign. Message standards apply to both sides of sign.
STREET NAME
Regulatory Permit Infomation Two Line Message
• Locate freestanding parking
identification signs at parking lot/area entrances or driveways. Only one lot should be identified per sign.
B
PRK21
• Do not rearrange panel order. • The bottom panel is designat-
CONFIGURATIONS
ed for parking information only .(i.e. A parking pass is needed from 8am-5pm) • Non-motorized parking areas
may be identified. See graphic layouts for correct usage.
PART COUNTS
Helpful Hints
PRK21:
• Keep in mind the intuitive
path of the user when locating and specifying exterior parking identification signs.
SINGLE SIDED
A
PNL.1
1
B
PNL.2
1
• Use only standard and ap-
proved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.23
PARTS
PRK21 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A PNL.1 1/4” thk. Painted aluminum panel w/ surface printed graphics. Paint all sides: P3.
1'-7"
B
2"
B Header Band
D Install Mounting
10"
STREET NAME
Regulatory Permit Infomation Two Line Message
C
PRK21 1 1/2” = 1’-0”
ELEVATION
CL
Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Lot ID
A
1"
1/4” thk. Painted aluminum panel w/ surface printed graphics. Surface mount to building facade; determine best mounting method via site conditions survey. Paint all sides: P2.
5"
C PNL.2
1'-0"
Mask and Paint front, top and sides: P1.
Lot ID
STREET NAME
5'-0" minimum
Regulatory Permit Infomation Two Line Message
D
PRK21 1/4” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.24
ELEVATION INSTALL ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK21
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
This Page Intentionally Left Blank
ELEVATION S E C T I O N G : PA R K I N G
2G.25
PARTS
PRK21 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A Sign Panel
C B
1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment
A Plan View no scale
Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
D Fastener
B
Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
G H C
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
A A J
D
A
I
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.26
K
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK21
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
Specifications
E F
Plan View
A
no scale
F Existing U-channel Post G Pin-mount Attachment
L A
Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
M P
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment
L A
Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
A
N Strap-mount Attachment Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
H M F
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
DETAIL S E C T I O N G : PA R K I N G
2G.27
PARTS
PRK21 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A RU_Logotype.eps 3/4” T-cap height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
B Copy 2” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
B Copy 1” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
D Parking_Symbol.eps
11 1/4"- maximum copy length
3/4"
1 1/4"
5 1/4"
A D B
align align
2" 1 3/4"
STREET NAME
1"
Lot ID
C L
3/4” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
align
E Copy
1 3/4"
6 1/2"
4” Diameter. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2. Weed out P from black vinyl background; to have background panel color.
PNL.1 (max. message)
C
1” = 1’-0”
align
3/4"
1 1/4" 2"
1 3/4"
1'-4 1/2"- maximum copy length
Regulatory Permit Infomation Two Line Message
E
PNL.2 (max. message) 1” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.28
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK21
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
Lot ID
2- Line ID Message
2 1/4"
STREET NAME TWO LINE
PNL.1- Variation
1”= 1’-0”
1”= 1’-0” “Bicycle Parking” is the only approved message for this panel layout.
Reg. Permit Info. 1-Line Message
C L
PNL.1- Variation
4 1/4"
ELEVATION
PNL.2- Variation
2 1/4"
1”= 1’-0”
Reg. Permit Information Up to 3-Lines
PNL.2- Variation 1”= 1’-0”
GRAPHIC LAYOUTS
Lot 55 HOES LANE
Lee Hall Parking Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT use this layout to identify parking lots or garages.
Lot 54,55 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT identify more than one lot per parking identification sign.
Lot 54,55 Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT exclude the street name from the parking identification.
Lot 54 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
No more than ONE parking message panel.
Lot 54
Permit Required at all Times Visitors: See Parking Kiosk for Permit
HOES LANE
Lot 54,55 Park here for lot 54, 55, 56, 57
ONLY permit information is to appear on PNL.6.
HOES LANE
Do NOT rearrange panel order or exclude panels.
GRAPHIC ELEVATION DONT’S S E C T I O N G : PA R K I N G
2G.29
This Page Intentionally Left Blank
2G.30
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK22
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
Guidelines • To identify parking areas
using the lot name and street associated with the lot. • Reinforce the brand equity
Lot ID
in the built environment with accent color & Rutgers logotype header.
A
• Use as a single-sided or
double-sided sign. Message standards apply to both sides of sign.
STREET NAME TWO LINE
Regulatory Permit Information Two Line Message
• Locate freestanding parking
identification signs at parking lot/area entrances or driveways. Only one lot should be identified per sign.
B
PRK22
• Do not rearrange panel order. • The bottom panel is designat-
CONFIGURATIONS
ed for parking information only (i.e. A parking pass is needed from 8am-5pm) • Non-motorized parking areas
may be identified. See graphic layouts for correct usage.
PART COUNTS
Helpful Hints
PRK21:
• Keep in mind the intuitive
path of the user when locating and specifying exterior parking identification signs.
SINGLE SIDED
A
PNL.1
1
B
PNL.2
1
• Use only standard and ap-
proved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.31
PARTS
PRK22 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A PNL.3 1/4” thk. Painted aluminum panel w/ surface printed graphics. Paint all sides: P3.
2'-3"
B
2"
B Header Band
D Install Mounting
10"
STREET NAME TWO LINE
Regulatory Permit Information Two Line Message
C
PRK22 1 1/2” = 1’-0”
CL
Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Lot ID
A
3/4"
1/4” thk. Painted aluminum panel w/ surface printed graphics. Surface mount to building facade; determine best mounting method via site conditions survey. Paint all sides: P2.
5"
C PNL.4
1'-0"
Mask and Paint front, top and sides: P1.
Lot ID
STREET NAME TWO LINE
5'-0" minimum
Regulatory Permit Information Two Line Message
D
PRK22 1/4” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.32
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK22
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
This Page Intentionally Left Blank
ELEVATION S E C T I O N A : G E N E R A L I N F O R M AT I O N
2G.33
PARTS
PRK22 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.34
K
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK22
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
Specifications
E F
Plan View
A
no scale
F Existing U-channel Post G Pin-mount Attachment
L A
Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
M P
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment
L A
Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
A
N Strap-mount Attachment Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
H M F
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
DETAIL S E C T I O N G : PA R K I N G
2G.35
PARTS
PRK22 PARKING IDENTIFICATION: W10E
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A RU_Logotype.eps 3/4” T-cap height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
B Copy 2” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
B Copy 1” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V2.
D Parking_Symbol.eps
11 1/4"- maximum copy length
3/4"
1 1/4"
5 1/4"
A D B
align align
2" 1 3/4"
STREET NAME
1"
Lot ID
C L
3/4” X-cap Height. Type: T2. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
align
E Copy
1 3/4"
6 1/2"
4” Diameter. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2. Weed out P from black vinyl background; to have background panel color.
PNL.3 (max. message)
C
1” = 1’-0”
align
3/4"
1 1/4" 2"
1 3/4"
1'-4 1/2"- maximum copy length
Regulatory Permit Infomation Two Line Message
E
PNL.4 (max. message) 1” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.36
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
PRK22
GRAPHIC LAYOUT
PARKING IDENTIFICATION: W10E
ELEVATION
2 1/4"
STREET NAME TWO LINE
PNL.3- Variation
PNL.3- Variation
1”= 1’-0”
1”= 1’-0”
4 1/4"
2- Line ID Message
Lot ID
Reg. Permit Info. 1-Line Message
C L
To be used for non-motorized parking areas only (i.e. Bicycle Parking).
PNL.4- Variation
2 1/4"
1”= 1’-0”
Reg. Permit Information Up to 3-Lines
PNL.4- Variation 1”= 1’-0”
GRAPHIC LAYOUTS
Lot 55 HOES LANE
Smith Hall Parking Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT use this layout to identify parking lots or garages.
Lot 54,55 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT identify more than one lot per parking identification sign.
Lot 54,55 Permit Required at all Times Visitors: See Parking Kiosk for Permit
Do NOT exclude the street name from the parking identification.
Lot 54 HOES LANE
Permit Required at all Times Visitors: See Parking Kiosk for Permit
No more than ONE parking message panel.
Permit Required at all Times Visitors: See Parking Kiosk for Permit
Lot 54 HOES LANE
Lot 54,55 HOES LANE
Park here for lot 54, 55, 56, 57
ONLY permit information is to appear on PNL.6.
Do NOT rearrange panel order or exclude panels.
GRAPHIC ELEVATION DONT’S S E C T I O N G : PA R K I N G
2G.37
This Page Intentionally Left Blank
2G.38
R U TG E R S U N I V E R S I T Y S I G N AG E S TA N DA R D S M A N UA L
SUB-SECTION SECTION G:
KSK10 SERIES
KSK10 Series – Kiosk Information KSK10 Series Overview Recommended sign type configurations shown. Additional module configurations must be approved by Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
Lot 9
Lot 9
BERGEN STREET
BERGEN STREET
Instructions for obtaining a parking pass:
Instructions for obtaining a parking pass:
1. Scan QR code
1. Scan QR code
2. Provide your license plate number
2. Provide your license plate number
3. Obtain a pass
3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
Parking Help: 215-219-4459 www.Rutgers.com
Sign Selection Process KSK11
KSK12
Below are the following steps for selecting the correct parking kiosk for your needs. A. Verify the parking area/lot name, street address and regulatory information. B. Analyze the location, mounting detail and space availability.
KSK10 SERIES: KSK11
KSK12
X
N/A
EXISTING POLE
N/A
X
VARIOUS FENCE MOUNT
N/A
X
VARIOUS WALL MOUNT
N/A
X
NEW POST
Notes: 1. Site survey for sign location required prior to determining-KSK type
? Questions? Please contact xxxxx
2G.40
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK11
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
A C Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number
D E
Guidelines
F
• Reinforce the brand equity
• Give parking instructions from
a pedestrian viewpoint only. in the built environment with accent color pole.
3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
• Locate signs throughout park90"
ing area to allow for a sight line from all parking spaces.
G
• Use as a single-sided or
double-sided sign. Message standards apply to both sides of sign.
D
• QR code needs to be
accessible by a standing or seated individual.
Comfiguration 1
• Modifying graphic language on H
Full length filler panels are used for single sided signs only (not shown)
I
Stop panel below grade line (not shown)
G J
Structural attachment angle (not shown)
CONFIGURATIONS
PART COUNTS
instruction panel will require approval by Rutgers Parking Authority and Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
CONFIGURATION 1:
*
*
SINGLE SIDED
DOUBLE SIDED
A
POST CAP
2
2
B
SIGN POST
2
2
C
PNL.1
1
2
D
FP_1
2
4
E
PNL.2
1
2
F
PNL.3
1
2
G
FP_2
1
2
H
FP_3
1
0
I
FP_S
2
2
J
ST. ANGLE
1
2
Helpful Hints • Keep in mind the visibility
and sight lines when locating and specifying exterior kiosk information signs. • Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed. For specification and ordering purposes, contact EMS Delaware; 231 Executive Drive Suite 11 Newark, DE 19702 USA Toll Free: 800-863-1496 Local Phone: 302-391-1370 Fax: 302-391-1371 Website: www.EasternMetal.com Email:
[email protected]
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.41
PARTS
KSK11
ELEVATION DETAIL
KIOSK INFORMATION
GRAPHIC LAYOUT
Specifications
1'-0 3/4"
A Post Cap 3 1/4"
9 1/2"
h B
6"
1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
3/4"
B Sign Post Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. *See post extrusion spec. information on Parts sheet.
A CEf j
1'-0"graphic panel
j h
KSK11 1/2” = 1’-0”
Back ElevationSingle side Sign
Plan ElevationSingle side Sign
C PNL.1 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
1/8"
A 1'-0" 1" 6" 1"
D FP_1
Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
G FP_2
e
d
2'-7"
2. Provide your license plate number 3. Obtain a pass
7'-6"
f Parking Help: 215-219-4459 www.Rutgers.com
B
3'-3"
g k l grade line
i KSK11 1/2” = 1’-0”
1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
2G.42
d
BERGEN STREET
1. Scan QR code
E PNL.2
F PNL.3
Lot 9
Instructions for obtaining a parking pass:
1/8” thk. Painted aluminum filler panel. Paint all sides: P1. Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
C
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK11
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
Specifications
H FP_3 1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
I FP_S 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
J Structural Angle 1/4” thk. Painted aluminum. L-angle, attached to back of sign panel, w/ hi-bond adhesive, and mechanically fastened to sign post. Paint all sides: P4. Paint fastener heads to match: P4.
K Concrete Footer / Pad
This Page Intentionally Left Blank
Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be below grade and landscaping, by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and repour sidewalk square.
S E C T I O N G : PA R K I N G
2G.43
PARTS
KSK11
ELEVATION DETAIL
KIOSK INFORMATION
GRAPHIC LAYOUT
Specifications
A Post Cap 1/8” thk. Pre-punched and painted aluminum post cap, mechanically fastened w/ tamper-resistant, spanner-head screws. Paint all sides: P4.
A
B Sign Post Rutgers owned custom, extruded sign post w/inset grooves for ease of panel install and removal. Paint all sides: P4. All drilled holes to be weather-proofed for water and environmental considerations. See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
F N O
becomes sign panel
C
H D
N O
D FP_1 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
E F
E PNL.2 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P2. *Use one panel only for . single sided sign.
F PNL.3 Painted aluminum panel w/ applied vinyl graphics. Custom extruded panel attachment to be mounted to back of panel w/ hi-bond adhesive. Paint all sides: P3. *Use one panel only for . single sided sign.
B G
Component Parts / Assembly Finished Sign
G FP_2 1/8” thk. Painted aluminum filler panel. Paint all sides: P1.
2G.44
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
3 1/4" 1 3/4"
1/8" typ.
G
KSK11
GRAPHIC LAYOUT
KIOSK INFORMATION
1 1/8"
B
C E F 7/8"
P
Specifications
H FP_3
1/8"
O P
1/8” thk. Painted aluminum filler panel. Paint all sides: P1. *Use only for single sided signs.
C E F
1/4"
panel height variessee elevations for height dimensions
O
7/8"
1/4" panel extrusion variessee elevations for height dimensions
1/8"
2"
4 1/4"
6"
1/8" typ.
DETAIL
3/4"
7/8"
3/4"
ELEVATION
Panel Detail no scale
J Structural Angle 1/4” thk. Painted aluminum. L-angle, attached to back of sign panel, w/ hi-bond adhesive, and mechanically fastened to sign post. Paint all sides: P4. Paint fastener heads to match: P4.
K Concrete Footer / Pad
3'-2" panel length
Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be below grade and landscaping, by others, where necessary.
Partial Horizontal Section 6” = 1’-0”
L M K
L Concrete Sidewalk If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and repour sidewalk square.
Plan Elevation at Sidewalk
4" above finished grade
no scale
B grade line
grade line
M Expansion Joint To accommodate concrete expansion and contraction.
N Sand Compacted sand for condensation drainage per engineering requirements.
O Attachment Bracket
L
Rutgers owned custom extruded bracket cut to match height of aluminum plate. Permanently mount to back of plate. *See post extrusion spec. information on Parts sheet.
M
K
P Sign Panel Plate N Vertical Section: Concrete Footer
Vertical Section: Concrete Footer
no scale
no scale
at concrete sidewalk condition
at earth / grass condition
1/8” Thk. aluminum plate cut to dimensions shown in elevations.
DETAIL S E C T I O N G : PA R K I N G
2G.45
PARTS
KSK11
ELEVATION
eq.
eq.
DETAIL CL
GRAPHIC LAYOUT
eq.
KIOSK INFORMATION
Specifications
A eq.
6” Height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
CL
A Information_Symbol.eps
B Copy PNL.1
1 1/8” X-cap Height. Type: T2. Tracking: +50. Apply to front surface of panel. Applied Vinyl: V2.
d Parking_Symbol.eps 4” Height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2.
E Kiosk_Graphics.eps Artwork provided by client. Surface print on vinyl and apply to aluminum face. Surface Print: S2 Paint Vinyl: P3.
7"- max. copy length
D
1/2"
align
B
3 3/16" 1 1/16"
1 1/8"
CL
CL
1/2” X-cap Height. Type: T1. Tracking: +50. Apply to front surface of panel. Applied Vinyl: V2.
2 3/4" 1 3/4"
2 3/4"
C Copy
1 1/2” = 1’-0”
C
PNL.2 1 1/2” = 1’-0”
Instructions for obtaining a parking pass:
E 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
PNL.3 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.46
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK11
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
1 3/4"
2- Line ID Message PNL.2- Variation 1 1/2” = 1’-0”
Lot ID
1"
STREET NAME TWO LINE
PNL.2- Variation 1 1/2” = 1’-0”
GRAPHIC LAYOUTS
Lot 9
BERGEN STREET
Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
Do NOT rearrange panel order or exclude panels.
Parking Help: 215-219-4459 www.Rutgers.com
Sign MUST be placed in an area of reach for a standing or seated individual.
GRAPHIC ELEVATION DONT’S S E C T I O N G : PA R K I N G
2G.47
This Page Intentionally Left Blank
2G.48
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK12
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
Guidelines
A
• Give parking instructions from
a pedestrian viewpoint only.
Lot 9
BERGEN STREET
• Reinforce the brand equity
in the built environment with accent color pole.
Instructions for obtaining a parking pass:
• Locate signs throughout park-
ing area to allow for a sight line from all parking spaces.
1. Scan QR code 2. Provide your license plate number
• Use as a single-sided or
3. Obtain a pass
double-sided sign. Message standards apply to both sides of sign.
Parking Help: 215-219-4459 www.Rutgers.com
• QR code needs to be
accessible by a standing or seated individual.
KSK12
• Modifying graphic language on
CONFIGURATIONS
instruction panel will require approval by Rutgers Parking Authority and Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
PART COUNTS
Helpful Hints
KSK12:
• Keep in mind the visibility
and sight lines when locating and specifying exterior kiosk information signs.
SINGLE SIDED
A
PNL.4
1
• Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate
state and local codes, as needed, for sign compliance, including Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N G : PA R K I N G
2G.49
PARTS
KSK12 KIOSK INFORMATION
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A PNL.4 1/4” thk. Painted aluminum panel with surface painted and vinyl graphics. Paint all sides: P3.
1'-0"
B Information Header Mask and paint all sides: P2.
C Reveals 1'-0"
B
1"
Mask and paint all sides: P4.
C
6"
Lot 9
BERGEN STREET
1"
B
4'-3"
Instructions for obtaining a parking pass:
B
2'-7"
1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
KSK12 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.50
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK12
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
5'-3" max. above sidewalk
Parking Help: 215-219-4459 www.Rutgers.com
D
KSK12: Install Elevation 1/4” = 1’-0”
Use only at existing poles that are walk-up accessible
Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number
3'-3" max. above sidewalk
3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
D
KSK12: Install Elevation 1/4” = 1’-0”
Use when handicap accessibility is required ie., at handicap parking areas
ELEVATION S E C T I O N G : PA R K I N G
2G.51
PARTS
KSK12 KIOSK INFORMATION
ELEVATION DETAIL GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.52
K
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK12
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
Specifications
F Existing U-channel Post G Pin-mount Attachment
L A
E F
Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
M P
H Spacer Plan View
A
no scale
1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment
E L
Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
A A
N Strap-mount Attachment Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
H M F
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section at channel post
Vertical Section at existing light pole
no scale
no scale
DETAIL S E C T I O N G : PA R K I N G
2G.53
PARTS
KSK12
eq.
eq.
DETAIL CL
GRAPHIC LAYOUT
eq.
KIOSK INFORMATION
ELEVATION
Specifications
A eq.
6” Height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V1.
CL
A Information_Symbol.eps
B Copy PNL.1
1 1/8” X-cap Height. Type: T2. Tracking: +50. Apply to front surface of panel. Applied Vinyl: V2.
d Parking_Symbol.eps 4” Height. Artwork provided by client. Apply to front surface of panel. Applied Vinyl: V2.
E Kiosk_Graphics.eps Artwork provided by client. Surface print on vinyl and apply to aluminum face. Surface Print: S2 Paint Vinyl: P3.
7"- max. copy length
D
1/2"
align
B
3 3/16" 1 1/16"
1 1/8"
CL
CL
1/2” X-cap Height. Type: T1. Tracking: +50. Apply to front surface of panel. Applied Vinyl: V2.
2 3/4" 1 3/4"
2 3/4"
C Copy
1 1/2” = 1’-0”
C
PNL.2 1 1/2” = 1’-0”
Instructions for obtaining a parking pass:
E 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
PNL.3 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2G.54
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
KSK12
GRAPHIC LAYOUT
KIOSK INFORMATION
ELEVATION
1 3/4"
2- Line ID Message PNL.2- Variation 1 1/2” = 1’-0”
Lot ID
1"
STREET NAME TWO LINE
PNL.2- Variation 1 1/2” = 1’-0”
GRAPHIC LAYOUTS
Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Lot 9
BERGEN STREET
Instructions for obtaining a parking pass: 1. Scan QR code 2. Provide your license plate number 3. Obtain a pass
Parking Help: 215-219-4459 www.Rutgers.com
Do NOT rearrange panel order or exclude panels.
Parking Help: 215-219-4459 www.Rutgers.com
Sign MUST be placed in an area of reach for a standing or seated individual.
GRAPHIC DONT’S S E C T I O N G : PA R K I N G
2G.55
2G.56
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SECTION H:
TRANSIT TR10 SERIES
TRANSIT IDENTIFICATION
Some transit signs were implemented prior to the completion of this Universitywide Standard. These signs have been documented and are represented in this section. There are some transit signs that are unique to the Health Science campus and can be found in Section J of this manual.
TR10 Series – Transit Identification AR10 Series Overview LIVINGSTON PLAZA
Recommended sign type configurations shown. Additional module configurations must be approved by Rutgers University Environmental Graphics Coordinator & or Department of Facilities, Planning and Development.
Sign Selection Process Below are the following steps for selecting the correct transit identification for your needs: A. Determine if the transit stop is new or existing. Determine number of routes that need to be identified on the transit identification sign.
TR11
B. Determine quantity needed for creating optimal sight lines based on bus stop length C. Analyze existing ground conditions and space availability. D. Review graphic dont’s to ensure proper selection. E. Prepare a mock-up to review with fabricator on site to ensure proper selection.
? Questions? Please contact xxxxx
2H.2
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
TR11
GRAPHIC LAYOUT
TRANSIT IDENTIFICATION
ELEVATION
LIVINGSTON PLAZA
Guidelines • Identify Rutgers transit stops. • Maintain the brand equity
in the built environment with Rutgers brand color. • Use as a double-sided
element. Placement and location should allow for optimal sight lines from the entry point. • Do not modify panel
configuration, color or any other physical or graphic elements. TR11
CONFIGURATIONS
PART COUNTS TR10 SERIES: LENGTH OF BUS STOP
NUMBER OF ROUTE IDENTIFICATION SIGNS NEEDED
10–20ft.
1
20–40ft.
2
Helpful Hints • Keep in mind the intuitive
transportation path of the user path when of the locating user when and locating specifying and arrival gateway specifying transit signs. signs. • Refer to all appropriate
NUMBER OF ROUTE IDENTIFICATION CLIPS NEEDED PER SIGN
NUMBER OF CLIPS NEEDED PER SIGN
0 Routes
0
1 Route
1
2 Routes
2
3 Routes
3
4 Routes
4
5 Routes
5
6 Routes
6
7 Routes
7
state and local codes, as needed, for sign compliance compliance, including Zoning, including, but not ADAAG, limited to MUTCD,ADAAG, zoning, etc. MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods all methods andand materials materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
SECTION H: TRANSIT
2H.3
PARTS
TR11
ELEVATION DETAIL
TRANSIT IDENTIFICATION
GRAPHIC LAYOUT
Specifications
A
Copy (Stop Name) 4 1/4” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
B PNL.1 0.125” thk. skins welded to structural framing. Paint: P5
C Route Clip 0.25” thk. panels welded together, w/ applied copy. Paint: P2
D Concrete Footer/Pad
eq.
eq.
1'-4"
4 1/4"
4 1/4"
1/4"
eq.
1'-0"
1/4"
4 3/4"
Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate windloads for individual structure. Footer to be Below grade and landscaping, by others, where necessary.
2'-0" eq.
10"
C
B
D
TR11 3/4” = 1’-0”
Plan Elevation
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2H.4
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
TR11
GRAPHIC LAYOUT
TRANSIT IDENTIFICATION
ELEVATION
16'-10"
9'-3"
Specifications
A
A
b
D
c
c
3 1/2" typ.
3"
1/2"
grade line Right Elevation
grade line Front Elevation
Left Elevation
TR11 3/8” = 1’-0”
ELEVATION SECTION H: TRANSIT
2H.5
PARTS
TR11
ELEVATION DETAIL
TRANSIT IDENTIFICATION
GRAPHIC LAYOUT
Specifications
A
Copy (Stop Name) 4 1/4” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
B PNL.1 0.125” thk. skins welded to structural framing. Paint: P5
C Route Clip 0.25” thk. panels welded together, w/ applied copy. Paint: P2
A
D Neoprene Gasket 1/16” thk. gasket, applied with hi-bond adhesive to inner faces of route clips.
E Fasteners Tamper-resistant, spanner head fasteners. Sign fabricator to review conditions and is responsible for engineering and number of fasteners required.
F Frame 2” x 4” Aluminum tube frame panel, welded together, Brace as necessary. Paint: P5
H Concrete Sidewalk
B
If sign is located at sidewalk, remove sidewalk square, pour footer below sidewalk and repour sidewalk square.
D C E
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2H.6
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
TR11
GRAPHIC LAYOUT
TRANSIT IDENTIFICATION
ELEVATION
Specifications
H Expansion Joint To accommodate concrete expansion and contraction.
I Concrete Footer/Pad
C
F
F
10"
J Sand
4"
E
D
B
Blade- Horizontal Section
Route Clip- Horizontal Section
no scale
no scale
B
G 1"
grade line
f 1"
B
f
grade line
4" above finished grade
B
Compacted sand for condensation drainage per engineering requirements.
4 1/4"
4 3/4"
4"
G
1/8"
4 1/4"
1/8"
1'-0"
Minimum 3’-0”d. concrete footer. Each footer to conform to engineering requirements and appropriate wind-loads for individual structure. Footer to be Below grade and landscaping, by others, where necessary.
H J
K L Vertical Section: Concrete Footer
Vertical Section: Concrete Footer
no scale
no scale
* Sign types, configurations and sizes are all site specific and need to be developed based upon each individual location.
at concrete sidewalk condition
DETAIL SECTION H: TRANSIT
2H.7
PARTS
TR11
ELEVATION DETAIL
TRANSIT IDENTIFICATION
GRAPHIC LAYOUT
Specifications
A Copy (Stop Name) 4 1/4"
1"
4" aligns
A 1 3/8"
B Copy (Route Name)
aligns
4 1/4” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1. 1 3/8” X-cap Height. Type: T1. Tracking: +25. Apply to front surface of panel. Applied Vinyl: V1.
B TR11- Route Clip (typical right side) 1 1/2” = 1’-0”
1 3/8"
aligns
1"
TR11- Route Clip (typical left side) 1 1/2” = 1’-0”
TR11- PNL.1, PNL.2 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
Do NOT change orientation of stop name.
Do NOT change route identifier locations or spacing.
GRAPHIC LAYOUTS
Do NOT change colors of any elements.
Do NOT change size, shape or proportion of elements.
GRAPHIC DON’TS
2H.8
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SECTION I:
REGULATORY INFORMATION RG10 SERIES
REGULATORY INFORMATION
RG20 SERIES
REGULATORY INFORMATION
Some regulatory information signs were implemented prior to the completion of this Universitywide Standard. These signs have been documented and are represented in this section. There are some regulatory information signs that are unique to the Health Science campus and can be found in Section J of this manual..
This Page Intentionally Left Blank
2I.2
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SUB-SECTION SECTION I:
RG10 SERIES
RG10 Series – Regulatory Information RG10 Series Overview Recommended sign type configurations shown. Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development.
N O P A R KI N G Logistical Services Receiving Department UNA UTHO RI Z E D VE HICLE S V E HI CLE S WI LL BE TI CKE TE D A ND TO WE D
RG11 Config. 1
NO PARKING L o g istic a l S e rvic e s Re c e ivin g D e pa rtme n t
Property of
EMPLOYEES ONLY RESTRICTED
UNAUTHORIZED VEHI C LES VEHICL ES WIL L BE TICK ETED AND TOWED
No Trespassing No Thoroughfare
RG11 Config. 2
RG12 Config. 1
ACCESS AREA DO NOT ENTER
RG12 Config. 2
Sign Selection Process Below are the following steps for selecting the correct regulatory sign for your needs.
Logistical Services Receiving ALL VISITORS/VENDORS MUST CHECK IN BEFORE ENTERING. FOR ASSISTANCE CALL: Receiving Desk (973) 972-4175 AFTER HOURS CALL: (732) 803-0052 / (973) 332-0023
A. Determine the message that you require. B. Review current campus signage in order to maintain message consistency.
Public Safety: (973) 972-4491/4492
RG13 Config. 1
Lo g i s t i cal S erv i ces R ecei v i ng ALL VI SI TORS/ VENDORS MUST CHECK I N BEFORE ENTERI NG. FOR ASSI STANCE CALL: Recei vi ng Des k ( 973) 972- 4175 AFTER HOURS CALL: ( 732) 803- 0052 / ( 973) 332- 0023 Publ i c Saf et y: ( 973) 972- 4491/ 4492
RESTRICTED ACCESS AREA DO NOT ENTER
RG13 Config. 2
RG14
C. Review graphic don’ts to ensure proper selection.
RG21
RG22
? Questions? Please contact xxxxx
2I.4
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG11
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Guidelines • Provide regulatory messaging
or restrictive information at a variety of different locations. • Brand reinforcement may
N O P A RKI NG L og istical Services Receivin g D ep artm en t U NA U T HO R IZED VE HICLE S V E HI CLE S W I LL B E T I CK E T E D A ND T O WE D
Configuration 1a
be needed where it is necessary to indicate that Rutgers University is the enforcing entity. Or if it is unclear if you are on Rutgers University property.
RE CE IV IN G Logistic a l Serv ice s Receiv i n g Departm e n t
• Use as a single-sided sign only.
Two single-sided signs may be mounted to either side of an existing pole or structure.
U NA UTHORIZED VE H IC LE S V E HICL E S W I LL B E TICKE TE D A N D T OWE D
Configuration 1b
CONFIGURATIONS
Helpful Hints
RG11 SERIES:
• Keep in mind the intuitive
USE FOR PARKING REGULATORY SIGNS/NO RUTGERS
RG11 config. 1a
USE FOR BUILDING REGULATORY SIGNS
RG11 config. 1b
path of the user when locating and specifying exterior regulatory signs. • Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate state
and local codes, as needed, for sign compliance, including, but not limited to Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.5
PARTS
RG11
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ vinyl applied. Paint all sides: P4.
B Color Band Mask and paint front, bottom, and sides: P1.
C Color Band
REC E IV ING
Mask and paint front, bottom, and sides: P2.
Logistical Services Receiving De p a r t m e n t U NA U THORIZED TRESPASSERS WILL BE PROSECUTED
C RG11: Configuration 1b 1 1/2” = 1’-0”
1'-4"
1'-5 1/4" 3/4"
1'-6"
NO PAR KING Logistical Services Receiving De p a r t m e n t
A
U NA U THORIZED VE HICLE S VEHI CL E S WILL BE TI CKETE D AND TOWE D
B RG11: Configuration 1a 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.6
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG11
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
D Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
6"
Lo g is t ical S er v ices R eceiv ing Depar t m ent
CL
RE C E I V I N G
5'-0" minimum
UN AUTH ORIZE D TRESPASSERS WILL BE PROSECUTED
RG11: Install Elevation 3/16” = 1’-0”
Use when RG11 regulatory information is located at building entrance
CL
N O P A R KI N G Logi st i cal Ser vi ces Recei vi ng Depar t ment
5'-0" minimum
U N A U TH OR IZ E D VEH I CL ES VEHI CLES WI LL B E TI CK ET ED A N D TO WED
D
RG11: Install Elevation 1/4” = 1’-0”
ELEVATION S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.7
PARTS
RG11
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.8
K
DETAIL
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG11
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
L A
E F
Plan View
A
no scale
F Existing U-channel Post G Pin-mount Attachment Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
M P
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment
L A
Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
A
N Strap-mount Attachment Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
N M F
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
DETAIL S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.9
PARTS
RG11
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Copy 1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V3.
B Copy 1” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
1 5/8"
3 1/8"
A
1" typ.
5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
1"
3 1/8"
C Copy
2 1/8"
align
5/8" typ.
align
B
3 5/8"
C
Up to Two Line Message Up to Three Line Message
Up to Two
Up to Two Line Message
Up to Three Line Message
Up to Three Line Message
Line Message RG11 (max. message)
3” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.10
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG11
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
NO SKATEBOARDING
D Copy 1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
(Symbol)
align
Specifications
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi a elit vitae odio interdum sagittis.
RG11 Alternate Graphic 3” = 1’-0”
R EC EI VING
D
NO SMOKING
Log ist ic a l S e r vic e s R e c e iving D e p a r t me n t
(Symbol)
align
UN A UT H OR IZED TRESPASSERS WILL BE PROSECUTED
VIOLATORS ARE SUBJECT TO FINE New Jersey Smoke-Free Air Act N.J.S.A. 26:3D-55
RG11- Variation
Line Message RG11 Alternate Graphic
3” = 1’-0”
3” = 1’-0”
GRAPHIC LAYOUTS
RECEIVING L o g is tical Se r vices Re c eiving De p artment UN A UT H O R I Z E D TRESPASSERS WILL BE PROSECUTED
Do NOT change the color of the graphic rule or copy.
UN AUTHORIZED TRESPASSERS WILL BE PROSECUTED
Logistical Services Receiving Department
UNAUTHORIZED VEHICLES VEHICLES WILL BE TICKETED AND TOWED NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS.
L o g ist ical S er vices R eceivin g Dep ar t m en t U N A U T H O R I Z E D VE H I C LE S V E H I C L E S W I L L B E T I C K E T E D A N D T O W E D NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS.
R E C EIVIN G
Do NOT rearrange heirarchy of information
RE C E I V I N G
Do NOT change panel layout to fit long lists of information.
Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development
Do NOT make copy smaller to fit long lists of information.
GRAPHIC ELEVATION DONT’S S E C T I O N A : G E N E R A L I N F O R M AT I O N
2I.11
This Page Intentionally Left Blank
2I.12
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG12
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Guidelines • Provide regulatory messaging
or restrictive information at a variety of different locations. • Brand reinforcement may
Property of
be needed where it is necessary to indicate that Rutgers University is the enforcing entity. Or if it is unclear if you are on Rutgers University property.
EMPLOYEES ONLY RESTRICTED
Two single-sided signs may be mounted to either side of an existing pole or structure.
DO NOT ENTER
No Thoroughfare
Configuration 1a
• Use as a single-sided sign only.
ACCESS AREA
No Trespassing
Configuration 1b
CONFIGURATIONS
Helpful Hints • Keep in mind the intuitive
RG12 SERIES: USE WITH RUTGERS LOGO-TYPE
RG12 config. 1a
USE WITHOUT RUTGERS LOGO-TYPE
RG12 config. 1b
path of the user when locating and specifying exterior regulatory signs. • Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate state
and local codes, as needed, for sign compliance, including, but not limited to Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.13
PARTS
RG12
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ vinyl applied. Paint all sides: P4.
B Color Band Mask and paint front, bottom, and sides: P1.
C Color Band Mask and paint front, bottom, and sides: P2.
EMPLOYEES ONLY R E S TR IC TE D A CCE SS AR EA DO NO T E N TE R
C RG12: Configuration 1b 1 1/2” = 1’-0”
1'-4" 3/4"
1'-3 1/4"
1'-0 1/2"
Property of
A
No Trespassing No Thoroughfare
B
RG12: Configuration 1a 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.14
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG12
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
D Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
6"
ACCESS AREA
CL
EMPLOYEES ONLY RESTRICTED
5'-0" minimum
DO NOT ENTER
RG12: Install Elevation 1/4” = 1’-0”
Use when RG12 regulatory information is located at building entrance
CL
Property of
No Trespassing
5'-0" minimum
No Thoroughfare
D
RG12: Install Elevation 1/4” = 1’-0”
ELEVATION S E C T I O N A : G E N E R A L I N F O R M AT I O N
2I.15
PARTS
RG12
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
K
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.16
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG12
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
L A
E F
Plan View
A
no scale
M P
F Existing U-channel Post G Pin-mount Attachment Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E L A A
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
N Strap-mount Attachment N M F
Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.17
PARTS
RG12
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Copy 1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V3.
B Copy 1” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
C Copy 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2. 2 1/8"
1 7/8"
1 1/2" T-cap height 1" typ.
B
A
align
2 1/8"
3 1/8"
3 1/2"
1"
A
Up to Two Line Message Up to Three Line Message
RG12 3” = 1’-0”
Up to Two Line Message Up to Three Line Message
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.18
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG12
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
3 1/8"
Specifications
RG12- Variation
3” = 1’-0”
3” = 1’-0”
D
NO SMOKING
1"
1/4" typ.
2 1/8"
2 3/4"
2 7/8"
1 1/8"
RG12- Variation
1 5/8" typ.
1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
EMPLOYEE
1 1/8" 1 5/8"
A CCESS AREA DO NOT ENT ER
5/8" typ.
3" typ.
D Copy
1/2"
VIOLATORS ARE SUBJECT TO FINE New Jersey Smoke-Free Air Act N.J.S.A. 26:3D-55
RG12- Variation
3” = 1’-0”
3” = 1’-0”
1/4" typ.
NO SKATEBOARDING
1/2"
1"
2 1/8"
1 1/8"
RG12- Variation
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi elit vitae odio interdum sagittis.
RG12- Variation 3” = 1’-0”
GRAPHIC LAYOUTS
ACCESS AREA DO NOT ENTER
Do NOT change the color of the graphic rule or copy.
Do NOT rearrange heirarchy of information
UNAUTHORIZED VEHICLES VEHICLES WILL BE TICKETED AND TOWED NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, .
Do NOT change panel layout to fit long lists of information.
U NA UT HO RI Z E D VE H IC L ES V E H I C L ES W I LL B E T IC K E T E D A N D T O W ED NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. U NA UT HO RI Z E D VE H I CL ES V E H I C L ES W I LL B E T IC K E T E D A N D T O W ED NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. U NA UT HO RI Z E D VE H I CL ES V E H I C L ES W I LL B E T IC K E T E D A N D T O W ED NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS.
Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development
Do NOT make copy smaller to fit long lists of information.
GRAPHIC ELEVATION DONT’S S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.19
This Page Intentionally Left Blank
2I.20
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG13
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Guidelines
Lo g is tic a l S erv ices Re c e iving ALL VI SI TO R S/VENDORS MUST C H EC K I N B EFO RE ENT ERING.
AL L VISIT ORS/VENDORS M UST CHECK IN BEFORE ENTERING.
• Brand reinforcement may
or restrictive information at a variety of different locations. be needed where it is necessary to indicate that Rutgers University is the enforcing entity. Or if it is unclear if you are on Rutgers University property.
FOR ASSISTANCE CALL: Receiv ing De sk (9 7 3 ) 9 7 2 - 4 175
FO R ASSI STAN C E CALL: R ecei vi ng D esk (973) 972-4175
AF T ER HOURS CALL: (7 3 2 ) 8 0 3 - 0 052 / (973) 332-0023
AFTER H O U R S C ALL: (732) 803-0052 / (97 3 ) 3 3 2 - 0 0 2 3
Pu blic Safety: (9 7 3 ) 9 7 2 - 4 491/4492
Publ i c Saf ety: (973) 972-4491/44 9 2
Configuration 1a
L o g is t ical Ser v i ces R eceiv i ng
• Provide regulatory messaging
• Use as a single-sided sign only.
Two single-sided signs may be mounted to either side of an existing pole or structure. Configuration 1b
CONFIGURATIONS
Helpful Hints
RG13 SERIES:
• Keep in mind the intuitive
USE WITH RUTGERS LOGO-TYPE
RG13 config. 1a
USE WITHOUT RUTGERS LOGO-TYPE
RG13 config. 1b
path of the user when locating and specifying exterior regulatory signs. • Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate state
and local codes, as needed, for sign compliance, including, but not limited to Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.21
PARTS
RG13
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ vinyl applied. Paint all sides: P4.
B Color Band Mask and paint front, bottom, and sides: P1.
C Color Band Mask and paint front, bottom, and sides: P2.
E m p loy ee P a r k in g O n l y U n iv er s i t y H a n g Ta g R e q u i re d U n au t h o r i ze d Veh i cl e s Will be Ticketed a n d Tow e d
C RG13: Configuration 1b 1 1/2” = 1’-0”
1'-3 1/4"
1'-4"
1'-0"
E m p loy ee P a r k in g O n l y
A
U n iv er s i t y H a n g Ta g R e q u i re d
3/4"
U n au t h o r i ze d Veh i cl e s Will be Ticketed a n d Tow e d
B RG13: Configuration 1a 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.22
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG13
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
D Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
6"
CL
Parking Only U n i v e r s i t y H a n g Ta g R e q u i re d
5'-0" minimum
U n a u t h o r i z e d Ve h i c l e s Will be Ticketed a n d To w e d
RG13: Install Elevation 1/4” = 1’-0”
Use when RG13 regulatory information is located at building entrance
CL
Employee Parking Only U n i v e r s i t y H a n g Ta g R e q u i re d
5'-0" minimum
U n a u t h o r i z e d Ve h i c l e s Will be Ticketed a n d To w e d
D
ID13: Install Elevation 1/4” = 1’-0”
ELEVATION S E C T I O N A : G E N E R A L I N F O R M AT I O N
2I.23
PARTS
RG13
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
K
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.24
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG13
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
L A
E F
Plan View
A
no scale
M P
F Existing U-channel Post G Pin-mount Attachment Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E L A A
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
N Strap-mount Attachment N M F
Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.25
PARTS
RG13
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Copy 1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V3.
B Copy 1” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
1 1/4"
2 1/4" 2 1/8"
A
B
2 5/8" 1"
5/8" typ.
1 5/8"
5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
1" typ.
C Copy
1 1/2"
align
C
Up to Two Line Message Up to Three Line Message
RG13 (max. message) 3” = 1’-0”
Up to Two Line Message
Up to Two Line Message
Up to Three Line Message
Up to Three Line Message
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.26
GRAPHIC ELEVATION LAYOUTS
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG13
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
D Copy
1 1/2"
1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
P a r k in g O n l y U n iv er s i t y H a n g Ta g R e q u i re d U n au t h o r i ze d Veh i cl e s Will be Ticketed a n d Tow e d
RG11- Variation 3” = 1’-0”
GRAPHIC LAYOUTS
Parking Only
Parking Only U n i v e r s i t y H a n g Ta g R e q u i re d U n a u t h o r i z e d Ve h i c l e s Will be Ticketed a n d To w e d Vehicles may park in designated spots along campus perimeter
U n i ve r s i t y H a n g Ta g R e q u i re d U n a u t h o r iz e d Ve h i c l e s Will be Ticketed a n d Tow e d
Do NOT change the color of the graphic rule or copy.
Do NOT rearrange heirarchy of information
Do NOT change panel layout to fit long lists of information.
Parking Only U N AU TH O R I ZED VEH I C LES VEH I C LES W I LL B E TIC ETED AN DE D TOVE WHI EDCLE NOSNOT PARK PARKING SPACES U NK AU TH ORIZ V E HI CLEIN S THESE W ILL BE UNDER ANY NOT LIMITED TOSPACES TI CKE TE D CIRCUMSTANCES, AN D TOW E D NOINCLUDING NOT PARK BUT IN THESE PARKING EVENTS, STUDENT ORIENTATIONINCLUDING DAYS, FACULTY SEMINARS. UNDER ANY CIRCUMSTANCES, BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. U N AU TH O R I ZED VEH I C LES VEH I C LES W I LL B E
TIC ETED AN DE D TOVE WHI EDCLE NOSNOT PARK PARKING SPACES U NK AU TH ORIZ V E HI CLEIN S THESE W ILL BE UNDER ANY NOT LIMITED TOSPACES TI CKE TE D CIRCUMSTANCES, AN D TOW E D NOINCLUDING NOT PARK BUT IN THESE PARKING EVENTS, STUDENT ORIENTATIONINCLUDING DAYS, FACULTY SEMINARS. UNDER ANY CIRCUMSTANCES, BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. U N AU TH O R I ZED VEH I C LES VEH I C LES W I LL B E TIC ETED AN DE D TOVE WHI EDCLE NOSNOT PARK PARKING SPACES U NKAU TH ORIZ V E HI CLEIN S THESE W ILL BE UNDER ANY NOT LIMITED TOSPACES TI CKE TE D CIRCUMSTANCES, AN D TOW E D NOINCLUDING NOT PARK BUT IN THESE PARKING EVENTS, STUDENT ORIENTATIONINCLUDING DAYS, FACULTY SEMINARS. UNDER ANY CIRCUMSTANCES, BUT NOT LIMITED TO
EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. U N AU TH O R I ZED VEH I C LES VEH I C LES W I LL B E TIC K ETED AN D TO W ED NO NOT PARK IN THESE PARKING SPACES U N AU TH ORIZ E D VE HI CLE S V E HI CLE S W ILL BE UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO TI CKE TE D AN D TOW E D NO NOT PARK IN THESE PARKING SPACES EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO
ORIENTATION FACULTY UEVENTS, N AU TH OSTUDENT R I ZED VEH I C LES VEHDAYS, I C LES W I LL BSEMINARS. E TIC K ETED AN D TO W ED NO NOT PARK IN THESE PARKING SPACES U N AU TH ORIZ E D VE HI CLE S V E HI CLE S W ILL BE UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO TI CKE TE D AN D TOW E D NO NOT PARK IN THESE PARKING SPACES EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS.
Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development
Do NOT make copy smaller to fit long lists of information.
GRAPHIC ELEVATION DONT’S S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.27
This Page Intentionally Left Blank
2I.28
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG14
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Guidelines • Provide regulatory messaging
or restrictive information at a variety of different locations. • Brand reinforcement may
be needed where it is necessary to indicate that Rutgers University is the enforcing entity. Or if it is unclear if you are on Rutgers University property.
RESTRICTED
• Use as a single-sided sign only.
ACCESS AREA
Two single-sided signs may be mounted to either side of an existing pole or structure.
DO NOT ENTER
RG14
CONFIGURATIONS
Helpful Hints • Keep in mind the intuitive
RG14 SERIES: USE AT BUILDING ENTRANCES THAT HAVE RESTRICTED ACCESS
path of the user when locating and specifying exterior regulatory signs.
RG14
• Use only standard and
approved nomenclature and abbreviations. • Refer to all appropriate state
and local codes, as needed, for sign compliance, including, but not limited to Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings.
PARTS
? Questions? Please contact xxxxx
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.29
PARTS
RG14
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ vinyl applied. Paint all sides: P1.
1'-4"
10"
RESTRICTED
A
ACCESS AREA DO NOT ENTER RG14 1 1/2” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.30
ELEVATION
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG14
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
D Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
6"
Parking Only
ACCESS AREA DO NOT ENTER
CL
RESTRICTED
U n i v e r s i t y H a n g Ta g R e q u i re d
5'-0" minimum
U n a u t h o r i z e d Ve h i c l e s Will be Ticketed a n d To w e d
RG14: Install Elevation 1/4” = 1’-0”
Use when RG14 regulatory information is located at building entrance
5'-0" minimum
CL
RESTRICTED ACCESS AREA DO NOT ENTER
D
RG14: Install Elevation 1/4” = 1’-0”
ELEVATION S E C T I O N A : G E N E R A L I N F O R M AT I O N
2I.31
PARTS
RG14
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Sign Panel 1/8” thk. Painted aluminum w/ surface printed copy. Provide matte clear-coat, all surfaces.
C B
B Existing Fence Picket Size and shape to be verified thru field conditions survey.
C L-angle Attachment Custom size L-angle cut 3/4” short, t. and b., of sign panel; mechanically fasten to fence picket.
A Plan View no scale
D Fastener Tamper-resistant, spanner head fastener. Sign fabricator to review conditions and is responsible for engineering and number of fasteners req’d.
B G H
E Nut and Bolt Attachment Threaded rod welded to back side of sign panel and bolted thru backer plate on opposite side of fence.
C A A J
D
A
I
K
Vertical Section
Vertical Section
Vertical Section
no scale
no scale
no scale
at metal picket stile condition
at pourous wall surface
at non-pourous wall surface
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
2I.32
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG14
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
Specifications
L A
E F
Plan View
A
no scale
M P
F Existing U-channel Post G Pin-mount Attachment Threaded rod drilled and tapped into back of cut-out form. Drill hole in wall surface and secure w/ hi-bond adhesive.
H Spacer 1/2” dia. x 1/4” d. Aluminum spacer w/ sandblasted edge returns. Provide matte clearcoat, all surfaces.
Plan View no scale
I Porous Wall Surface J VHB Foam Tape Attachment 1/16” thk. Exterior grade VHB foam tape.
E L A A
K Non-Porous Wall Surface L Existing Light Pole M Strap-mount Attachment Bandit, or equal, stainless steel sign mounting attachment bracket, as required by sign engineering.
N Strap-mount Attachment N M F
Bandit, or equal, stainless steel sign mounting straps, as required by sign engineering.
* Install Mounting Surface mount to building facade, fence or existing pole; determine best mounting method via site conditions survey. Height of sign varies based on field survey conditions. 5’-0” above grade is optimal.
Vertical Section
Vertical Section
no scale
no scale
at channel post
at existing light pole
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.33
PARTS
RG14
ELEVATION DETAIL
REGULATORY INFORMATION
GRAPHIC LAYOUT
Specifications
A Copy 1 5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V3.
B Copy
3 3/8"
2 3/8"
1” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
2 1/8" typ.
A
align
5/8” X-cap Height. Type: T1. Tracking: +100. Apply to front surface of panel. Applied Vinyl: V2.
1" typ.
C Copy
RG13: (only message allowed) 3” = 1’-0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
U n a u t h o r i z e d Ve h i c l e s Will be Ticketed a n d To w e d Vehicles may park in designated spots along campus perimeter
Do NOT change the color of the sign.
Do NOT change panel layout to fit long lists of information.
UN A UTH OR IZE D VE HI CLE S V E HI CLE S WILL B E TI CKE TE D A N D TOWE D NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. UN A UTH OR IZE D VE HI CLE S V E HI CLE S WILL B E TI CKE TE D A N D TOWE D NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. UN A UTH OR IZE D VE HI CLE S V E HI CLE S WILL B E TI CKE TE D A N D TOWE D NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS. UN A UTH OR IZE D VE HI CLE S V E HI CLE S WILL B E TI CKE TE D A N D TOWE D NO NOT PARK IN THESE PARKING SPACES UNDER ANY CIRCUMSTANCES, INCLUDING BUT NOT LIMITED TO EVENTS, STUDENT ORIENTATION DAYS, FACULTY SEMINARS.
Do NOT make copy smaller to fit long lists of information.
GRAPHIC LAYOUTS
Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development
GRAPHIC DONT’S
2I.34
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG14
GRAPHIC LAYOUT
REGULATORY INFORMATION
ELEVATION
This Page Intentionally Left Blank
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
2I.35
This Page Intentionally Left Blank
2I.36
R U TG E R S U N I V E R S I T Y S I G N AG E S TA N DA R D S M A N UA L
SUB-SECTION SECTION I:
RG20 SERIES
RG20 Series – Regulatory Information RG20 Series Overview Recommended sign type configurations shown. Additional layouts and configurations must be approved by Rutgers University Environmental Graphics Coordinator and or Department of Facilities, Planning and Development.
RG21
RG22
RG21
RG22
Sign Selection Process Below are the following steps for selecting the correct regulatory sign for your needs. A. Determine the message that you require. B. Review current campus signage in order to maintain message consistency. C. Review Rutgers Visual Identity Manual to ensure proper layout.
2I.38
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG21
GRAPHIC LAYOUT
REGULATORY IDENTIFICATION
ELEVATION
Specifications
A Copy 1” X-cap Height. Type: T2. Tracking: +25. Apply second-surface of glass. Applied Vinyl: V7.
Guidelines • Provide regulatory,
overall width determined by letter height
1" typ.
informational or restrictive information at building entrances.
1 5/8" typ.
• Brand reinforcement may or
may not be needed depending on building type.
A
• Use as a single-sided sign only. • An arrow may be used
align
for clarity.
RG21 3” = 1’-0”
ELEVATION
Helpful Hints • Keep in mind the intuitive
path of the user when locating and specifying locating and specifying exterior regulatory exterior regulatory signs. signs. • Use only standard and
Rutgers New Jersey Dental School
Rutgers New Jersey Dental School
CL
align
5'-0" bottom edge of door
If Entrance is Locked, Please Proceed to University Hospital Emergency Entrance
CL
RG21: Install Elevation
If Entrance is Locked, Please Proceed to University Hospital Emergency Entrance
• Refer to all appropriate state
and local codes, as needed, for sign compliance, including, but not including, but limited not limited to Zonto ing, ADAAG, Zoning, ADAAG, MUTCD, MUTCD, etc. etc. • Sign fabricator to provide
all relevant engineering calculations and provide all methods and materials of construction in shop drawings. RG21: Install Elevation
3/16” = 1’-0”
3/16” = 1’-0”
Use when sign is used alone
Use when sign is used w/ an ID50 series sign
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
CL
approved nomenclature and abbreviations. and abbreviations.
INSTALLATION
2I.39
This Page Intentionally Left Blank
2I.40
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
RG22
GRAPHIC LAYOUT
REGULATORY IDENTIFICATION
ELEVATION
overall width determined by letter height
Specifications
1 1/2"
A Copy 1 3/4"
C L
1” X-cap Height.
1" typ.
Tracking: +25. Apply second-surface
If Entrance is Locked, Please Proceed to University Hospital Emergency Entrance
of panel. Applied Vinyl: V7.
B Arrow_Symbol.eps 4” Height. Artwork provided by client. Apply
A
to second surface of panel. Applied Vinyl: V1. Rotate arrow around object center-point.
Uses
align
2"
1 5/8" typ.
Type: T2.
A
• To provide sequential guidance
Secondary Message Secondary Message
throughout the campus with strategic placement and programmed messaging. • Brand: Reinforce the brand equity in the built environment with accent color and Rutgers logo-type.
RG22: Graphic Layout 3” = 1’-0”
• Use when a directional sign is
ELEVATION
needed with one arrow and one regular message. • Use as a single-sided or doublesided sign. Message standards apply to both sides of sign. • Do not include parking messages. • Do not include more than three total lines per message.
Rutgers New Jersey Dental School
Rutgers New Jersey Dental School
CL
CL
CL
Helpful Hints • Keep in mind the intuitive path of the user when locating and specifying exterior
5'-0" bottom edge of door
If Entrance is Locked, Please Proceed to University Hospital Emergency Entrance
align
Secondary Message Secondary Message
regulatory signs.
If Entrance is Locked, Please Proceed to University Hospital Emergency Entrance
Secondary Message Secondary Message
• Use only standard and approved nomenclature and abbreviations. • Refer to all appropriate state and local codes, as needed, for sign compliance, including, but
RG21: Install Elevation
RG21: Install Elevation
3/16” = 1’-0”
3/16” = 1’-0”
Use when sign is used alone
Use when sign is used w/ an ID50 series sign
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
S E C T I O N I : R E G U L ATO RY I N F O R M AT I O N
not limited to Zoning, ADAAG, MUTCD, etc. • Sign fabricator to provide all relevant engineering calculations and provide all methods and materials of
INSTALLATION
construction in shop drawings.
2I.41
2I.42
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
SECTION J:
HEALTH SCIENCES
PARTS
ID6
ELEVATION DETAIL
BUILDING IDENTIFICATION
GRAPHIC LAYOUT
General Notes 1'-2"
These sign specifications do not follow the standards set in section F, building identification, series ID30.
1'-6"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
Message Message Message Message Message Message
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
4"
1"
Bldg. ####
BUILDING ADDRESS
ID6: Front Elevation NTS
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.2
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
ID7
GRAPHIC LAYOUT
BUILDING IDENTIFICATION
ELEVATION
General Notes
12"
7'-0 15/16" +/-
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
Doctors Office Center ID7: Front Elevation C25 at Newark Campus NTS
These sign specifications do not follow the standards set in section F, building identification, series ID4zzz0.
8"
24'-8 1/16" +/-
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
Medical Education Building ID7: Front Elevation F69 at New Brunswick Campus NTS
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
3"
10'-10 1/2" +/-
Children’s Transitional Residence ID7: Front Elevation N718 at Piscataway Campus NTS
12"
8'-2 1/16" +/-
Medical Science Building ID7: Front Elevation C61 at Newark Campus NTS
22"
12 1/2"
5'-2 7/16" +/-
School of Dental Medicine ID7: Front Elevation C42 at Newark Campus NTS
ELEVATION
? Questions? Please contact xxxxx
S E C T I O N J : H E A LT H S C I E N C E S
2J.3
PARTS
SKY.1-2 SKYLINE IDENTIFICATION
ELEVATION DETAIL GRAPHIC LAYOUT
19'-6" 5"
32"
5'-3"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
3'-0"
General notes
36 3/4"
13'-0 1/2"
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
SKY.1: Front Elevation at New Brunswick, Nj
4'-6"
NTS
29'-2 1/2" 5"
7'-10"
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
Side Elevation
16"
These sign specifications do not follow the standards set in section F, building identification, series SKY10z.
Side Elevation SKY.2: Front Elevation at New Brunswick, NJ NTS
30'-5" +/-
24"
2 1/2"
28"
52”
Side Elevation
SKY.2: Front Elevation at New Brunswick, NJ NTS
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.4
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
DR.2(a)(c)
GRAPHIC LAYOUT
VEHICULAR DIRECTIONAL
ELEVATION
General Notes 3'-2"
These sign specifications do not follow the standards set in section D building identification, series DR20.
University Behavioral Health Care
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
2'-3"
4'-10"
2'-2"
1" 4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx DR.2a: Front Elevation TO19, Piscataway Campus
3'-2"
1" 4"
1/2”= 1’0”
3'-2"
Child Health Institute of New Jersey
2'-3"
2'-3"
Medical Science Bldg.
4'-2"
Behavioral Health Sciences Bldg. 6'-10"
5'-8"
3'-0"
1" 4"
Clinical Academic Bldg.
DR.2c: Front Elevation D100, Newark Campus
DR.2: Front Elevation E703.1, New Brunswick Campus
1/2”= 1’0”
1/2”= 1’0”
ELEVATION
? Questions? Please contact xxxxx
S E C T I O N J : H E A LT H S C I E N C E S
2J.5
PARTS
DR.2 (j)(n) VEHICULAR DIRECTIONAL
ELEVATION DETAIL GRAPHIC LAYOUT
General Notes 3'-2"
1" 4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
3'-2"
1" 4"
Exit to Raritan Road
1'-2" 1" 1'-4"
5'-3"
1'-2"
Lot 5B 12 AVE.
DR.2j: Front Elevation C89, Scotchplains Campus
DR.2n: Front Elevation D118, Newark Campus
1/2”= 1’0”
1/2”= 1’0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
Lot 5A 12 AVE.
2'-3"
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
Conference Center
2'-3"
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
6'-1"
1"
2'-2"
These sign specifications do not follow the standards set in section D, building identification, series DR2 and DR40.
ELEVATION
Questions? Please contact xxxxx
2J.6
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
DR.2 (p)
GRAPHIC LAYOUT
VEHICULAR DIRECTIONAL
ELEVATION
General Notes 3'-2"
School of Dental Medicine
These sign specifications do not follow the standards set in section D, building identification, series D20.
Doctors Office Center
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
1"
Bergen St. Entrance
Parking 12th Ave.
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
2'-3"
1'-2"
7'-4"
3'-5"
1" 4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
DR.2p: Front Elevation D722, Newark Campus 1/2”= 1’0”
ELEVATION
? Questions? Please contact xxxxx
S E C T I O N J : H E A LT H S C I E N C E S
2J.7
PARTS
DR.3 (a) VEHICULAR DIRECTIONAL
ELEVATION DETAIL GRAPHIC LAYOUT
General Notes 3'-2"
6"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
RWJ
2'-7"
EMERGENCY
Hospital
Hospital
Cancer Institute of New Jersey
Cancer Institute of New Jersey
4" 1'-10"
6'-8 1/2"
ROBERT WOOD JOHNSON UNIVERSITY HOSPITAL
1'-0"
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
ROBERT WOOD JOHNSON UNIVERSITY HOSPITAL
EMERGENCY
These sign specifications do not follow the standards set in section D, building identification, series xxxx. A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
RWJ
Side A DR.3a: Front Elevation E&20.1, New Brunswick Campus 1/2”= 1’0”
Side B ** EMERGENCY is only message that is internally illuminated.
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.8
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS ELEVATION DETAIL GRAPHIC LAYOUT
This Page Intentionally Left Blank
ELEVATION S E C T I O N J : H E A LT H S C I E N C E S
2J.9
PARTS
DR.1
(c)
VEHICULAR DIRECTIONAL
ELEVATION DETAIL GRAPHIC LAYOUT
3'-2"
General Notes
4'-2"
Cancer Center 12'-1"
These sign specifications do not follow the standards set in section D, building identification, series DR20.
1" 4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
Medical Science Bldg.
varies
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components. Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
Behavioral Health Sciences Bldg.
DR.1c: Front Elevation D722, Newark Campus 1/2”= 1’0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.10
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS ELEVATION DETAIL GRAPHIC LAYOUT
This Page Intentionally Left Blank
ELEVATION S E C T I O N J : H E A LT H S C I E N C E S
2J.11
PARTS
MN.1
ELEVATION DETAIL
MONUMENT
GRAPHIC LAYOUT
11'-5"
General Notes The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only. 6'-4" 1'-7" 1"
NEWARK
3"
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
H E A LT H S C I E N C E S
1'-6"
These sign specifications do not follow the standards set in section C building identification, series MN10.
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
MN.1: Front Elevation C03, Newark Campus 1/4”= 1’0”
4'-6"
1'-2 1/2"
3 1/4" +/-
2 5/8"
2'-0"
1 1/4" +/-
4"- all around
MN.1: Side Elevation
MN.1: Existing Sign
1/4”= 1’0”
NTS
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.12
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS
DETAIL
MN.1
GRAPHIC LAYOUT
MONUMENT
ELEVATION
General Notes The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
11'-5"
5'-0"
These sign specifications do not follow the standards set in section C, building identification, series MN10.
H E A LT H S C I E N C E S
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
1'-6" 3"1"
SOMERSET
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
MN.1: Front Elevation M176, Somerset Campus 1/4”= 1’0”
P
2 5/8"
2'-0"
1 1/4" +/-
4"- all around
FO
4'-6"
1'-2 1/2"
3 1/4" +/-
MN.1: Side Elevation
MN.1: Existing Sign
1/4”= 1’0”
NTS
ELEVATION
? Questions? Please contact xxxxx
S E C T I O N J : H E A LT H S C I E N C E S
2J.13
PARTS
MN.1
ELEVATION DETAIL
MONUMENT
GRAPHIC LAYOUT
11'-1"
General Notes
1'-2 3/4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only. These sign specifications do not follow the standards set in section, C building identification, series MN10.
MN.1: Top Elevation @ ###, Somerset 1/4”= 1’0”
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
1"
4'-6"
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
10'-3"
1'-11"
H E A LT H S C I E N C E S SOMERSET
7'-5"
MN.1: Front Elevation #### @ Somerset Campus 1/4”= 1’0”
7" +/-
3 1/4" +/-
2 1/2"
General Notes: 1 1/4" +/-
1"
1. Matte, clear-coat all sign components for protection against natural elements and sun exposure. 2. All footer conditions to be verified in field and a. reuse footer/foundation if viable; b. engineer new footer/ foundation per information collected in field survey. 3. Remove existing sign where required. 4. Provide weather-proofing, weep-holes, tight-seal gasketing, etc., as required.
MN.1: Side Elevation #### @ Somerset Campus NTS
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.14
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
PARTS ELEVATION DETAIL
PDR.1
(a)(k)
PEDESTRIAN DIRECTIONAL
GRAPHIC LAYOUT
General Notes 2'-1 1/2"
1" 4"
The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
Kessler Teaching Labs
These sign specifications do not follow the standards set in section E, building identification, series PDR10.
4'-6"
2'-6"
Admissions Office
1'-7"
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components. Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
PDR.1a: Front Elevation N729.1, Piscataway Campus 1/2”= 1’0”
1" 4"
2'-1 1/2"
RWJMS Research Bldg. & School of Public Health
5'-2"
3'-2"
Kessler Teaching Labs RWJMS Research Tower University Behavioral Health Care
1'-7"
Waksman Institute of Microbiology
PDR.1k: Front Elevation N754, Piscataway Campus 1/2”= 1’0”
ELEVATION
? Questions? Please contact xxxxx
S E C T I O N J : H E A LT H S C I E N C E S
2J.15
PARTS
PDR.1
(m)
PEDESTRIAN DIRECTIONAL
ELEVATION DETAIL GRAPHIC LAYOUT
General Notes The signs shown on this page were fabricated and installed for Rutgers Health Sciences and are unique to that campus only.
2'-0 3/4"
Sign Shop drawings can be acquired through Rutgers facilities at xxx.xxx.xxxx
1'-3"
Conference Center Entrance
1'-7"
3'-3"
A thorough site survey of the existing sign and attachment method is required prior to fabricating new signs or new sign components.
1" 4"
These sign specifications do not follow the standards set in section E, building identification, series PDR10.
PDR.1m: Front Elevation C83, Scotch Plains Campus 1/2”= 1’0”
For typography, finish/material and symbol specifications refer to Manual Part 2, Section A: Graphic Standards.
?
ELEVATION
Questions? Please contact xxxxx
2J.16
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L
This Page Intentionally Left Blank
S E C T I O N J : H E A LT H S C I E N C E S
2J.17
2J.18
R U TG E R S U N I V E R S I T Y U N I V E R S I T Y W I D E WAY F I N D I N G A N D S I G N AG E S TA N DA R D S M A N UA L