RIG INSPECTION CHECKLIST

RIG INSPECTION CHECKLIST RIG NAME:____________________________ DATE:_______________________ TOOLPUSHER: __________________________ INSPECTED BY:___...
Author: Gwenda Higgins
378 downloads 3 Views 331KB Size
RIG INSPECTION CHECKLIST

RIG NAME:____________________________

DATE:_______________________

TOOLPUSHER: __________________________ INSPECTED BY:___________________________

Date

Ints.

CONTRABAND POLICY 1 Are logs kept on all rig team members who are taking prescription drugs and kept on file?

Comments: Date

RIG ORIENTATION

Ints.

1 Are the Rig Managers meeting with every new rig team member upon arrival on rig site? 2 Are Rig Orientation check lists being filled out? 3 Personal Emergency Contact Information Sheet 4 Are written Short Service Employees (SSE) orientation/mentor checklists on file? Comments: Date

Ints.

SAFETY MEETINGS 1 Are pre tour (daily) safety meetings being performed according to the procedure in the Safety Manual? 2 Are pre tour (daily) safety meeting forms being filed by Driller in hard leaf binder ?

Comments: Date

Ints.

J.S.A. 1 Are written J.S.A.'s being performed before each job task? 2 Are written J.S.A.'s forms being completed and filed by Driller in hard leaf binder?

Comments: Date

Ints.

INJURY OR ILLNESS PROCEDURES 1

Are injury or illness reports being filled out legibly, properly and completely according to the procedures in the Safety Manual.

2 Is the Third Party Incident report being filled out and forwarded to divisional office for review? Comments: Date

Ints.

INCIDENT EVALUATION 1 Are all incidents being reported; documented on the correct forms and sent to the HSE Department?

Comments:

Date

Ints.

RIG INSPECTION PROCEDURES 1 Are copies of the last rig inspection available at rig site? Have discrepancies been evaluated and corrected? 2 Are written weekly Rig Inspections being completed?

Comments:

Page 1

Date

Ints.

SALA BLOCKS 1

Is the 135' Sala Block in good working condition? (Located in Derrick). If not, this must be corrected prior to pre-spud approval! Serial #________________

2 Are both of the 30' Sala Blocks in good working condition? (Under the sub-structure area) Serial #'s _____________ _____________ 3 Is Derrick climber assist in good working condition? If not, this must be corrected prior to pre-spud 4

Is the 16' Talon in good working condition? (Located at Monkeyboard). If not, this must be corrected prior to pre-spud approval! Serial # ___________

Comments: Date

Ints.

RIG SITE NOTICES AND POSTING REQUIREMENTS 1 Is the Emergency Phone Number List posted? (Number to local Emergency contacts) 2 Are written instructions/directions to the Hospital posted in a prominent place? 3 Is the 5 in 1 sign (OSHA) posted in Toolpusher quarters? 4 Are Orion signs posted at the entrance to the location? 5

Are the SPCC Orion Drilling Company personnel emergency numbers current and posted in the Rig Manager office?

Comments: Date

Ints.

WORK PERMITS 1 Is Work Permit form being utilized in accordance with Safety Manual. 2 Is a portable gas monitor available on location? 3 Are calibrations records being maintained at rig site?

Comments: Date

Ints.

FIRE PREVENTION AND CONTROL 1 Are fire extinguishers located in accordance with the rig Fire Extinguisher Location Plan? 2 Tags: Are fire extinguishers being inspected monthly, annually and properly tagged? 3 Files: Is the monthly Fire Extinguisher Inspection form being properly filed?

Date

Ints.

FORKLIFT VEHICLES 1 Are personnel who operate the forklift trained and qualified? 2 Is the forklift inspection being performed at the beginning of each tour and kept on file?

Comments: Date

Ints.

BLOWOUT PREVENTION AND CONTROL 1 Are duties of each rig team member for well control drills posted? 2 Are well control drills conducted once per hitch and recorded on I.A.D.C.? 3 Are Well Control Training certificates current and posted in Toolpusher quarters?

Comments:

Page 2

Date

Ints.

HAZARDOUS COMMUNICATION PLAN/EMPLOYEE RIGHT TO KNOW Is a list of all chemicals being used on the current job kept on file and made available to all employees? 1 (Check MSDS book) 2 Does each employee know where the MSDS is located?

Comments: Date

Ints.

SAFETY OBSERVATION PROGRAM 1 Has the S.O.C. Program been implemented on this rig? 2 Have all supervisors been trained in the S.O.C. Program? 3 Have all rig team members been trained in the S.O.C. program by supervisors? 4 Are S.O.C. cards being filled out properly?

Comments:

Date

Ints.

TOOLPUSHER QUARTERS 1. Is housekeeping adequate? 2. Are there two means of escape? (Second door or kick out window.) 3. Is a First Aid Kit available onsite? 4. Is electrical system in good condition ? (wiring, fuse boxes and receptacles) 5. Are 5 visitors Hard Hats available? 6. Is a fire extinguisher properly maintained and located? 7. Is First Aid station sign in from of Toolpushers trailer? 8. Is Toolpusher Trailer properly grounded? 9 Are smoke detectors working properly? 10 Are AC vents clean and filters changed as needed? 11

Is eyewash station complete with correct solution, bottles unopened and valid expiration date? 2 bottles needed.

Comments: Date

Ints.

TRANSFORMER 1. Is transformer properly grounded? 2. Are all wires in good condition? 3. Is spark shield in place? 4. Are all switch box and connector box covers in place and properly labeled, with no exposed openings? 5. Is transformer shell in good condition?

Comments:

Page 3

Date

Ints.

MEETING / CHANGE ROOM 1. Is housekeeping adequate? 2. Is the lighting adequate and properly snubbed or bolted to a hard surface? 3. Are all electrical outlets and wiring in good condition? 4. Is a fire extinguisher properly maintained and located? 5.

Are change lockers in good condition and kept in orderly fashion and used only for employees personal effects?

6. Is the change room properly grounded? 7. Are AC vents clean and filters changed as needed? 8 Is a stretcher available with backboard, 4 way sling and cover and easily accessed? Comments: Date

Ints.

CREW QUARTERS 1. Is housekeeping adequate? 2. Are the showers, sinks and toilets working properly and cleaned daily? 3. Are non-slip surfaces provided in shower stalls and mats provided at entrance? 4. Is the lighting adequate, with covers or globes installed and properly maintained? 5. Are AC vents clean and filters changed as needed? 6. Is electrical system in good condition ? (wiring, fuse boxes and receptacles) 7 Are there two means of escape? (Second door or kick out window.) 8 Is the trailer properly grounded? 9 Are smoke detectors working properly? 10 Is a fire extinguisher properly maintained and located?

Comments: Date

Ints.

PARTS ROOM 1. Is housekeeping adequate? 2. Is the lighting adequate and properly snubbed or bolted to a hard surface? 3. Are all electrical outlets and wiring in good condition? 4. Is a fire extinguisher properly maintained and located? 5. Are storage bins kept orderly? 6. Are all the safety signs posted? (Eye Protection - full faceshield - required when chipping/grinding 7. All flammables (paints, thinners, etc.) must be properly labeled and stored in flammable locker. 8 Is the Lubster properly labeled? (Mfg's stickers and label for each type of oil 9 Is parts room properly grounded? 10 Is the air compressor in good condition and does it have all its components? (guards, etc.)

Comments:

Page 4

Date

Ints.

DIESEL TANKS 1. Is the lighting adequate and properly snubbed or bolted to a hard surface? 2. a b c

Are safety signs posted and visible? (Signs must be on all 4 sides) DANGER - DIESEL FUEL, NO SMOKING FLAMMABLE 1993 DOT - diamond decal

3. Is a fire extinguisher properly maintained and located? 4. Is proper access (ladder) provided to top of tanks? 5. Are all diesel hoses, lines and unions of the approved type and free of leaks? 6. Is housekeeping adequate? 7.

Is there a containment wall or ditching provided around the diesel tank will it contain or divert the capacity of the diesel tank and is it kept drained? Unless on Boarded location.

8. Is containment area free of supplies and equipment? 9. Is the diesel tank properly grounded? If not, this must be corrected prior to pre-spud approval! 10. Is (Notice) Transport truck must be grounded to diesel skid. Date

Ints.

GENERATOR / SCR AREA 1. Are non-conductive floor mats of proper type in SCR House? 2. Are all switch box and connector box covers in place and properly labeled, with no exposed openings? 3. Are all V-belts, sheave and shaft guards in place? If not, this equipment must be LO/TO! 4. Are lock-out and tags provided and used when working on electrical and mechanical equipment? 5.

Is the electrical wiring, connections, conductors and receptacles adequate and properly maintained protected and in good working condition?

6. Is the lighting adequate and properly snubbed or bolted to a hard surface? 7. Is the exhaust system guarded or insulated? (The requirements are currently under review) 8. Is a fire extinguisher properly maintained and located? 9. Is housekeeping adequate? 10. Are safety signs posted and visible? DANGER HIGH VOLTAGE - One on each door and on electrical panels on stairs to engine compound a area b CAUTION HEARING PROTECTION REQUIRED - one on each entrance door c CAUTION DO NOT USE WATER HOSE AROUND ELECTRICAL EQUIPMENT d DANGER HIGH VOLTAGE e DANGER: LOCK/OUT BEFORE SERVICING f Authorized Personnel Only Sign on Entrance Door 11 Is pressure washer unit grounded? 12. Are guards in place?

Page 5

13. Are all walkways free of obstructions and properly maintained? 14. Is oil and grease kept to a minimum under engines? 15. Is structure sufficiently grounded? If not, this must be corrected prior to pre-spud approval!

16.

Are all covers installed on the high voltage leads from Generators to SCR House to protect unsafe contact?

17. Is the emergency lighting working? 18 Are suitcases present? If so, are doors/hinges in safe working condition? Comments:

Date

Ints.

AIR COMPRESSOR AND VOLUME TANK AREA 1. Excess oil cleaned up? 2 All guards in place? 3 Is housekeeping adequate? 4 Are pop-off valves installed? 5 Are all gauges present and in proper working order? 6 Are bleed valves installed and in proper working order? 7 Are safety signs posted and visible? a "Compressed Air" and "Starts Automatically" b "Non-Flammable" on the Air Volume Tank(s) 8 Is Skid properly grounded? 9 Is the cold start in good condition and all its components? (guards, etc.)

Comments:

Date

Ints.

MUD HOPPER AREA 1. Is the housekeeping adequate? 2. Are mud additives stored properly and in orderly fashion? 3. Is the lighting adequate and properly snubbed or bolted to a hard surface? 4. Are all chemicals properly labeled according to our Hazard Communication program? 5. Are safety signs posted? (located on rear of Parts House) 6. Is eyewash station provided and in good working condition? a Eye-wash safety sign posted b Is path to the eye-wash station clear and no more than 15' from the mixing area? 7 Is the mud hopper unit properly grounded? 8 Is the work platform grating in good condition? (wood platforms are not authorized)

Comments:

Page 6

Date

Ints.

MUD PUMP AREA 1. Is all moving machinery, such as drive belts, shafts, gears, etc. properly guarded?

2.

Is discharge from relief valves piped to a safe location and are discharge lines properly anchored with all bolts in place and of proper size? If not, this must be corrected prior to pre-spud approval!

3. Are the relief valve shear pins from the manufacture and the proper size and are the covers in place?

4.

Are all bolts in place at the Discharge Manifold and Module? If not, this must be corrected prior to pre-spud approval!

5. Are the weep holes on pumps modules properly guarded?

6 Are safety signs posted and visible? a DANGER: LOCK/OUT EQUIPMENT BEFORE SERVICING 7 Are electrical wiring, sockets and terminal boxes in good condition? 8 Is the lighting adequate and properly snubbed or bolted to a hard surface? 9 Is housekeeping adequate? 10 Is the mud pump structure properly grounded? 11

Are vibrator hoses (both ends) provided Safety Snubs and properly clamped to hoses? If not, this must be corrected prior to pre-spud approval!

12

Do all vibrator hoses have 4-part shackles and safety cables with factory eyes and inspection tag? If not, this must be corrected prior to pre-spud approval!

13 Are covers provided over the pony rods on the mud pumps and kept closed? 14 Is the lifting arm in good working condition and properly labeled to weight capacity? Comments:

Date

Ints.

WATER TANKS 1. Are all electrical wires in good working condition? 2. Is skid properly grounded? 3. Are all guards in place? 4. Is lighting adequate and in good working condition? 5. Are non-potable water signs posted? 6. Are Confined Space - Permit Required signs posted? 7. Is housekeeping adequate in this area? 8 Is a fire extinguisher properly maintained and located? 9 Are all electrical components (switches, etc.) in good working order?

Comments:

Page 7

Date

Ints.

Hydraulic Power Unit (HPU) 1. Is skid properly grounded? 2. Are all electrical wires in good working condition? 3. Is unit free of Hydraulic leaks? 4. Are all hoses in good working condition and free of leaks? 5. Are all guards in place and bolted down? 6. Is housekeeping adequate in this area? 7. Is a fire extinguisher properly maintained and located? There are two F/E attached to HPU skid. 8 If equipped with air volume tank, is gauge in good working condition and is tank properly labeled? 9. Are both support braces/stands in place? If not, this must be corrected prior to pre-spud approval!

10. Is the main tray pinned to pad-eye? If not, this must be corrected prior to pre-spud approval! 11 Is the cold start in good working condition and its components? (guards, etc.) Comments: Date

Ints.

TRIP TANK / CHOKE MANIFOLD / GAS BUSTER 1 Is the stairws and handrail in good working condition? 2 Is skid properly grounded? 3. Are all pins and keepers in place? 4. Are beams in good working conditions and not damaged? 5. Are all valve handles in place and free of damage? 6. Is 4" line from manifold to BOP in place? 7. Are all lines on Gas Buster in place? 8. Is lighting adequate and light fixture in good working condition 9. Are all guards in place and bolted down? 10 Is wiring free of damage and in good working condition? 11. Are all the handles on choke manifold installed and are they in good condition? 12. Are all valves and gauges in proper working order and valves properly lubricated on the choke manifold? 13 Is a fire extinguisher properly maintained and located? 14 Is housekeeping adequate in this area?

Comments: TO BE INSPECTED BY RIG MANGER / TOOLPUSHER 15 Are all bolts uniformly installed? (Minimum requirement is 2-3 threads past nut) 16

Is D-Ring, Choke Line and Safety Clamp installed on Trip Tank Skid (this is not rigged up during prespud normally)

Comments:

Page 8

Date

Ints.

MUD TANK AREA/ EQUIPMENT SKID 1.

Are the mud pit walkways and stairs equipped with guard rails and properly maintained? (No more than a 6" gap)

2.

PPE: Are safety googles / faceshield, chemical gloves and aprons available at the caustic mixing barrel? If not, this must be corrected prior to pre-spud approval!

3. Is the PPE storage box clean? 4. Is the PPE box labeled with "Safety Equipment Inside"? 5. Is only authorized equipment inside? 6. Is the caustic mixing barrel properly labeled? CAUSTIC BARREL – WEAR GOGGLES, GLOVES, FULL FACE SHIELDS AND APRON WHILE a MIXING CAUSTIC. b CAUTION CORROSIVE MATERIAL eye, face, body protection and respirator required 7

Is the caustic mixing barrel properly rigged up? If not, this must be corrected prior to pre-spud approval!

8 Is a splash guard and baffle present on the caustic tank? 9

Is eyewash station provided and in good working condition? If not, this must be corrected prior to prespud approval!

10 Is the path to the eyewash station clear? 11

Is the safety shower and components in good working condition? (plumbing/piping, handle, filter system, etc.) If not, this must be corrected prior to pre-spud approval!

12 Are all shafts and couplings guarded and properly secured? 13 Is lighting adequate and electrical wiring and receptacles properly mounted and in good condition? 14 Is the lighting adequate and properly snubbed or bolted to a hard surface and explosion proof? 15 Is a fire extinguisher properly maintained and located? 16 Are stairways and walkways clear of obstructions? 17 Are all floor openings properly guarded? 18 Are steps secured and properly angled? 19 Are handrails properly secured? (No more than 6" gap) 20 Is the mud pit system properly grounded? 21 Is all moving machinery, such as drive belts, shafts, gears, etc. properly guarded? 22

Are all bolts in the electrical receptacles and not broken? (If broken, this equipment is no longer explosion proof)

23 Is housekeeping adequate in this area? Comments:

Page 9

Date

Ints.

RIG FLOOR Is the "Crown-o-Matic" function tested each tour and documented on the IADC report and set for 1. drilling or tripping mode? Must visually verify the High and Low EDS set points. If not, this must be corrected prior to pre-spud approval! 2. Is the drill line in satisfactory condition? 3. Is air hoist line in good condition with factory eyes and inspection tags? 4. Does the hoist line have a proper swivel and hook? 5. Does air hoist have drum guard and line guide and in good condition? 6.

Are the tong lines in satisfactory condition with inspection tags installed and are they properly secured? If not, this must be corrected prior to pre-spud approval!

7.

Change all jagged ends of wire rope on the tong lines, Mud Bucket etc. to factory eyes to prevent injury to personnel?

8. Do tong lines have 4 part shackles? 9. Are all cables using wire clamps equipped with factory eyes with a 3 clamp minimum? 10. Are the tong dies in satisfactory condition and are retainer pins installed properly? 11. Are the tong jaws retaining pins secured with cutter keys, nuts or spreader type pins? 12. Are all adjusting weights kept inside the tong counterweight buckets? 13. Is all wire rope protected from rubbing against any derrick structural member? 14. Is the Pipe Spinner guarded and are nylon tethers attached to use as handles? 15. Is the Pipe Spinner suspended to prevent personal injury? 16. Is the rig floor decking in satisfactory condition? 17. Is the working area around the rotary provided with non-slip decking or mats? 18. Is the mouse hole kept covered when not in use? 19. Are all guard rails around the rig floor in place and in good condition? (No more than 6" gap) 20. Are all floor openings properly guarded? If not, this must be corrected prior to pre-spud approval! 21. Is V-door handrail opening protected with a gate closed when not handling pipe? 22.

Is the lighting adequate, properly snubbed or bolted to a hard surface; and are all lights equipped with guards and globes?

Are the rotary and kelly spinner hoses in satisfactory condition and is rotary hose snubbed-off with 23 safety chain or wire rope to the derrick leg and the swivel? If not, this must be corrected prior to prespud approval! 24 Are all hand tools in satisfactory condition and properly stored?

Page 10

25 Are subs, bits, etc. properly stored in a sub rack? 26

Is excess mud, oil and grease removed from the floor area as soon as possible during normal operating procedures?

27 Are employees provided with and wearing required personal protective equipment? 28 Is housekeeping on the rig floor satisfactory? 29 Are all stairways leading to the rig floor in good condition and free of obstruction and properly secured? 30 Are the B.O.P. remote controls labeled? 31 Is there a safety guard installed on the Blind remote handle? 32 Are bug blowers properly guarded? 33 Are safety signs posted and visible? a. AUTHORIZED PERSONNEL SIGN b. CAUTION EYE PROTECTION REQUIRED 34 Is a fire extinguisher properly maintained and located? 35 Are the kelly cock and safety valve wrenches readily available? 36 Are slip handles, dies, pins and keys in good condition? 37 Is a safety valve installed on the kelly? 38 Is the inside B.O.P. safety valve properly rigged and lubricated? 39 Is mud bucket rigged properly and in working order? 40 Is the B.O.P. choke unit in proper working order? 41

Is the water hose the proper length (six inches from rotary table)? If not, this must be corrected prior to pre-spud approval!

42 Is the drill line roller guide properly installed and in good condition? 43 Are all bolts present on the junction box on the traction motors? 44 Is Tail-rope being used at the V-Door? 45 Is the Rotary Table lock working and in good condition? 46

Is the condition of the Snub Lines within acceptable limits and have inspection tags? If not, this must be corrected prior to pre-spud approval!

47

Elevators must have locking or nylon nuts on elevator ears. If not, this must be corrected prior to prespud approval!

48 Is the safety latch on elevators in good working condition? Comments:

Page 11

DERRICK RIG MANGER / TOOLPUSHER REQUIRED TO INSPECT DERRICK PRIOR TO DERRICK BEING RAISED Date

Ints. 1.

Is the derrick ladder securely mounted with proper equipment? No altered equipment allowed. If not, this must be corrected prior to pre-spud approval!

2.

Is the derrick ladder equipped with a Lad-Safe Cable System, two Lad-Safe sleeves and Climb Assist system and good working condition? If not, this must be corrected prior to pre-spud approval!

3. Is the derrick ladder clear of all obstructions? 4.

Does the derrick ladder have a minimum clearance of seven (7) inches between the derrick and the back of the ladder?

5. Are all sections of the derrick ladder properly aligned? 6.

Is the derrickman's work belt in good condition and equipped with both a belly line and a tail line? If not, this must be corrected prior to pre-spud approval!

7. Is the upper derrick free from loose tools or other materials which could possibly fall? 8. Are all derrick sheaves and lines properly secured and located to avoid rubbing? 9. Are derrick fingers snubbed? 10.

Are crown sheaves in satisfactory condition? If not, this must be corrected prior to pre-spud approval!

11.

Is the aircraft warning light at the crown in operating condition? If not, this must be corrected prior to pre-spud approval!

12.

Are all girts, legs and braces in satisfactory condition, properly secured and free from damage? If not, this must be corrected prior to pre-spud approval!

13.

Is the standpipe properly secured to the derrick with all bolts and nuts installed on clamps? If not, this must be corrected prior to pre-spud approval!

14.

Is the lighting adequate and properly snubbed or bolted to a hard surface? If not, this must be corrected prior to pre-spud approval!

15.

Are all personnel required to wear a safety harness with lanyard when working in or on the derrick at elevations of six feet (or more) above the rig floor? Is 100% tie-off being utilized at six feet (or more)?

16. Are decking and handrails on walkarounds in good condition? 17.

Are all assembly pins in place and secured with keepers? If not, this must be corrected prior to prespud approval!

18.

Is secondary fall protection installed from the scorpion / hangman? If not, this must be corrected prior to pre-spud approval!

19.

Is the SALA Block secured with a nylon strap or shackle? If not, this must be corrected prior to prespud approval!

20.

Are all bolts in the derrick in place, tightened and have nylon-locking nuts? If not, this must be corrected prior to pre-spud approval!

21. Is there a 1/4" rope installed on the hook of the SALA Block? 22 Is the mule line in working order? 23 Is the squawk box in derrick in good working condition? Comments:

Page 12

Date

Ints.

DRILLER'S CABIN 1. Are there two means of Egress (exits)? 2.

Is eyewash station complete with correct solution, bottles unopened and valid expiration date? There must be two bottles.

3.

Is a fire extinguisher properly maintained and located? (Check fire extinguisher inside cabin and outside cabin)

4. Is housekeeping adequate? 5. Is all electrical wiring and receptacles in good condition? 6. Is the lighting adequate and properly snubbed or bolted to a hard surface? 7. Are Orion shut-in procedures posted on the bulletin board on the rig floor? 9. Are all windows in the doghouse in good condition? 10. Are windshield wipers working and in good condition? 11. Is the emergency lighting working? 12. Is the skid properly grounded? If not, this must be corrected prior to pre-spud approval! Comments: Date

Ints.

SUB-STRUCTURE/ BOP AREA 1. Is the lighting adequate, properly snubbed or bolted to a hard surface and explosion proof? 2. Are all bolts and nuts in place at the casing head, BOP's and are they properly secured? 3.

Are all discharge lines properly snubbed on both ends e.g., Kill Line, Fill-up Up Line and Injection Line if present?

4. Are diverter valves properly installed? 5. Is the conductor or BOP's properly braced and turnbuckles snubbed? (Do all cables have thimble eyes?) 6. Are 4-part shackles in place with nut & cutter-pin? 7.

Are substructure members free from damage and are all securing bolts, nuts, pins and safety pins in place with keepers?

8. Is housekeeping in the BOP and substructure area satisfactory? 9. Are the snubs cables for B.O.P. in good condition and installed properly? 10. Is the SALA Block protected? 11. Is there a 1/4" rope connected to the clip/hook on the SALA Block? 12. Is all electrical wiring and outlets in good condition? 13. Is the cellar cover available and in place? 14. Has weight bucket and cage been inspected and is it in good working condition? 15. Is the skid properly grounded? Comments:

Page 13

Date

Ints.

DRAW WORKS / MUD BOAT AREA 1. Are all guards in place? 2. Is housekeeping adequate? 3.

Are all bolts in place on the drill line anchor and are they securely tightened with lock washers? If not, this must be corrected prior to pre-spud approval!

4.

Is drawworks unit bolted down on all four sides? If not, this must be corrected prior to pre-spud approval!

5. Drill line in good working condition? 6. If equipped, are roller guides installed and in good working condition? 7.

Is the drill line installed properly on anchor drum and pin to keep from jumping off? If not, this must be corrected prior to pre-spud approval!

8. Is the skid properly grounded? 9 Is derrick dolly in good working condition? 10 Check hinges and cables on ramp of mudboat 11 If equipped with air volume tank, is gauge in good working condition and is tank properly labeled? Comments:

Date

Ints.

ACCUMULATOR AREA RIG MANGER / TOOLPUSHER REQUIRED TO INSPECT THIS SECTION AFTER PRE-SPUD HAS OCCURRED 1. Is the accumulator fluid level and manifold in satisfactory condition? 2. Does the equipment hold accumulator pressure without leaking? 3. Are accumulator gauges installed, working properly, and properly labeled? 4. Is there a safety guard installed on the Blind remote handle? 5. a b c.

Are all Safety signs posted? DANGER THIS EQUIPMENT STARTS AUTOMATICALLY PRECHARGE WITH NITROGEN ONLY Bottles marked with “NON FLAMMABLE” gas placards.

6. Is the skid properly grounded? 7. Is the lighting adequate and properly snubbed or bolted to a hard surface? 8. Is all electrical wiring and outlets in good condition? 9. Is housekeeping adequate? 10 Are moving parts on wireline unit properly guarded? 11 If equipped with air volume tank, is gauge in good working condition and is tank properly labeled? 12 Accumulator certified in the last 6-months by a 3rd party? 13 All all moving components for accumlator covered? Comments:

Page 14

Date

Ints.

HYDRAULIC CATWALK 1. Is housekeeping in area adequate? 2. Is catwalk in good condition? 3. Is the lighting adequate and properly snubbed or bolted to a hard surface? 4. Are cylinders in good operational order on indexers. 5. Is V-Door chute in good condition? 6. Are shear pins in good condition and tightened? 7. Is skate aligned with chain and in good working condition? 8. Are hoses in good working condition and free of leaks? 9 Are guards in place? 10 Are daily inspections being done? 11 Are all security bolts, nuts and safety pins in place with keepers? 12 Are all grease fittings in place and kept lubricated? 13. Is the catwalk properly grounded? 14 Are bumper guards in good condition on gull-wings? 15 Is the pull-back cable system in good working condition?

Comments: Date

Ints.

PIPE RACK AREA 1.

Is each layer of pipe properly chocked with factory plastic chocks; front and back? If not, this must be corrected prior to pre-spud approval!

2. Do pipe racks have proper stops on both ends? 3.

Is the Geronimo line anchored properly on both ends with the distance being 2 times the height. If not, this must be corrected prior to pre-spud approval!

4.

Is Geronimo landing area clear? (6 ft. on each side). If not, this must be corrected prior to pre-spud approval!

5. Do all cables have a thimble and the proper amount of cable clamps? (min. 4) 6. Is derrick stand ladder provided and free of defects? Comments: Date

Ints.

TOP DRIVE HOUSE (If applicable) 1. Is the lighting adequate and properly snubbed or bolted to a hard surface? 2. Is the fire fighting equipment adequate and maintained and located? 3. Are storage bins organized? 4. Is housekeeping adequate? 5. Is the top drive house grounded? If not, this must be corrected prior to pre-spud approval! 6 Are all electrical cables off of ground?

Comments: Page 15

Date

Ints.

ENVIRONMENTAL 1. Are storage containers/sacks in good condition, free from corrosion/rips or leakage? 2. Are containers being stored properly, kept closed and in separate secured area? 3. Are containers labled properly? 4. Do all containers wih liquid inside have proper labels?

Comments: Date

Ints.

GENERAL 1. Do all Fuse boxes have a "Danger High Voltage" sticker on the outside cover? 2. Are all harnesses and lanyards marked with the date put into service? 3. Are the boards on location in good condition and no large gaps or loose boards? 4 Is the distance to the first rung greater than 12" on any of the fixed ladders? 6. Are whip-checks installed on all fittings (unions, quick connects)? 7. Are all fire extinguishers mounted at least 1" off the deck in a proper bracket? 8. Are all employees complying with the policy not carry a cell phone, cigarettes or lighter to their work areas? 9. Are all ladder safety cable systems tight with thimbles on both ends? 10. Are all skids properly grounded?

Comments:

Date

Ints.

THIRD PARTY EQUIPMENT 1. Is all third party equipment properly grounded?

Comments:

RIG MANAGER / TOOLPUSHER SIGNATURE:

HSE ADVISOR SIGNATURE:

COMPANY REP SIGNATURE: