RENO Plasma Sterilizer More Fast
RENO - S20 Ideal for Dental and Eye clinic with its fast turnaround time and compact size
Table top model
RENO - S20 More Fast Sterilization
Specification TOTAL CYCLE TIME Eco Cycle Advanced Cycle
About 21min. About 38min.
PROCESSING TEMPERATURE Below 55℃ DIMENSIONS & WEIGHT Dimensions Weight
470(H)×655(W)×640(D)mm 116Kg
STERILIZATION CHAMBER Configuration Total Volume Shelf Material
Rectangular 18L, 170(H)×260(W)×410(D)mm Two-tired shelf (Option) Stainless Steel
DOOR Door Type Door Control
Single Door Manual
STERILANT Liquid Chemical Agent Concentration & Usage
Hydrogen Peroxide 3.6ml (50%), 1 Cycle/Cassette
CONNECTION Electricity Power Consumption
230V~, Single Phase, 50/60Hz or 200V Single Phase, 50/60Hz 1.5 KVA
PROGRAM Control Self-Test Mode Printer Outputs Data Storage
Micro Processor Automatic Built-in Thermal Printer Memory Card
DISPLAY Screen Alarm
Color-coded Touch Screen Audible & Visable Alarm
MOBILITY Mobile wheels or Cart
Cart-mounted with 4 locking wheels (Option)
AIR INLET BACTERIA ETENTION FILTER HEFA Filter 99.97% Efficiency at 0.3 micron(0.3×10-6) REGULATORY APPROVALS CE 0120 / ISO 13485 / ISO 9001 OPERATIONAL ENVIRONMENT Temperature 5 ~ 40℃ Humidity 5℃~30℃/ below 80%, 31℃~40℃/ below 50%
Easy-to-use Sterilization Agent
User Friendly interface
Easy-to-use, single-use cassette type ● No required additional consumables for waste system. ●
●
asy-to-use, color-coded E touch screen.
Cart with locking wheels (option )
Spacious chamber design Removable two-tiered shelf ● Free contactable chamber wall-Error free ●
Universal data acquisition system
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910
RENO Plasma Sterilizer More Reliable
RENO - S30 Ensure greater efficiency with the proven sterilization performance plus added its compact size.
RENO - S30 More Reliable Sterilization
Specification TOTAL CYCLE TIME Eco Cycle Advanced Cycle
About 27min. About 45min.
PROCESSING TEMPERATURE Below 55℃ DIMENSIONS & WEIGHT Dimensions Weight
1,010(H)×570(W)×830(D)mm 190Kg
STERILIZATION CHAMBER Configuration Rectangular Total Volume 34L, 185(H)×300(W)×610(D)mm Material Stainless Steel DOOR Door Type Door Control
Single Door Manual
STERILANT Liquid Chemical Agent Concentration & Usage
Hydrogen Peroxide 4ml (50%), 1 Cycle/Cassette
CONNECTION Electricity Power Consumption
230V~, Single Phase, 50/60Hz or 200V Single Phase, 50/60Hz 2.5 KVA
PROGRAM Control Self-Test Mode Printer Outputs Data Storage
Micro Processor Automatic Built-in Thermal Printer Memory Card
DISPLAY Screen Alarm
Color-coded Touch Screen Audible & Visable Alarm
MOBILITY Mobile wheels or Cart
Built-in 4 locking wheels
AIR INLET BACTERIA ETENTION FILTER HEFA Filter 99.97% Efficiency at 0.3 micron(0.3×10-6) REGULATORY APPROVALS
CE 0120 / ISO 13485 / ISO 9001
OPERATIONAL ENVIRONMENT Temperature 5 ~ 40℃ Humidity 5℃~30℃/ below 80%, 31℃~40℃/ below 50%
Universal data acquisition system
User Friendly interface ●
Easy-to-use, color-coded touch screen.
Easy-to-use Sterilization Agent Easy-to-use, single-use cassette type ● No required additional consumables for waste system. ●
Spacious chamber design Durable and easy-to-clean chamber materials ● Free contactable chamber wall-Error free ●
Built-in Thermal printer
Built-in 4 locking wheels
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910
RENO Plasma Sterilizer More Economic
RENO - D50 Maximize efficiency with two selectable chambers as sterilization needs.
RENO - D50 More Economic Sterilization
Specification TOTAL CYCLE TIME Eco Cycle Advanced Cycle
About 27min. About 45min.
PROCESSING TEMPERATURE Below 55℃ DIMENSIONS & WEIGHT Dimensions Weight
1,280(H)×570(W)×830(D)mm 290Kg
STERILIZATION CHAMBER Configuration Total Volume Material
Rectangular (Double Chamber) 30L, 185(H)×300(W)×548(D)mm 30L, 185(H)×300(W)×548(D)mm Stainless Steel
DOOR Door Type Door Control
Two Door Manual
STERILANT Liquid Chemical Agent Concentration & Usage
Hydrogen Peroxide 4ml (50%) x 2 chambers 1 Cycle / 2 Cassettes (Double Chamber)
CONNECTION Electricity Power Consumption
230V~, Single Phase, 50/60Hz 2.5 KVA
PROGRAM Control Self-Test Mode Printer Outputs Data Storage
Micro Processor Automatic Built-in Thermal Printer Memory Card
DISPLAY Screen Alarm
Color-coded Touch Screen Audible & Visable Alarm
MOBILITY Mobile wheels or Cart
Built-in 4 locking wheels
AIR INLET BACTERIA ETENTION FILTER HEFA Filter 99.97% Efficiency at 0.3 micron(0.3×10-6) REGULATORY APPROVALS
CE 0120 / ISO 13485 / ISO 9001
OPERATIONAL ENVIRONMENT Temperature 5 ~ 40℃ Humidity 5℃~30℃/ below 80%, 31℃~40℃/ below 50%
User Friendly interface ●
Universal data acquisition system
Easy-to-use, color-coded touch screen.
Easy-to-use Sterilization Agent Spacious chamber design ● ●
Easy-to-use, single-use cassette type ● No required additional consumables for waste system. ●
Selectable Double Chamber Free contactable chamber wall-Error free
Built-in Thermal printer
Built-in 4 locking wheels
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910
RENO Plasma Sterilizer More Effective
RENO - S130 Ideal for Large-sized hospital needed optimal efficiency with its large chamber volume.
RENO - S130 More Effective Sterilization
Specification TOTAL CYCLE TIME Non-Lumen Cycle Eco Cycle Advanced Cycle
About 28min. About 45min. About 62min.
PROCESSING TEMPERATURE Below 55℃ DIMENSIONS & WEIGHT Dimensions Weight
1,547(H)×778(W)×1,120(D)mm 440Kg
STERILIZATION CHAMBER Configuration Total Volume Shelf Material
Rectangula 131.4L, 400(H)×450(W)×730(D)mm Removable Two-tired Shelf Stainless Steel
DOOR Door Type Door Control
Single Door Manual
STERILANT Liquid Chemical Agent Concentration & Usage
CONNECTION Electricity Power Consumption
230V~, Single Phase, 50/60Hz or 200V Single Phase, 50/60Hz 3 KVA
PROGRAM Control Self-Test Mode Printer Outputs Data Storage
Micro Processor Automatic Built-in Thermal Printer Memory Card
DISPLAY Screen Alarm
Wide Touch Screen Audible & Visable Alarm
MOBILITY Mobile wheels or Cart
Built-in 4 locking wheels
AIR INLET BACTERIA ETENTION FILTER HEFA Filter 99.97% Efficiency at 0.3 micron(0.3×10-6) REGULATORY APPROVALS
Hydrogen Peroxide 10ml (50%), 1 Cycle / Cassette
CE 0120 / ISO 13485 / ISO 9001
OPERATIONAL ENVIRONMENT Temperature 5 ~ 40℃ Humidity 5℃~30℃/ below 80%, 31℃~40℃/ below 50%
User Friendly interface ●
Easy-to-use Sterilization Agent
Easy-to-use, color-coded touch screen.
Easy-to-use, single-use cassette type ● No required additional consumables for waste system. ●
Universal data acquisition system Spacious chamber design Removable two-tiered shelf ● Free contactable chamber wall-Error free ●
Built-in Thermal printer
Built-in 4 locking wheels
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910
RENO Plasma Sterilizer More Advanced
RENO - S130D Advanced plasma technology and versatility to meet your growing sterilization needs.
Double Door System
RENO - S130D More Advanced Sterilization
Specification TOTAL CYCLE TIME Non-Lumen Cycle Eco Cycle Advanced Cycle
About 28min. About 45min. About 62min.
PROCESSING TEMPERATURE Below 55℃ DIMENSIONS & WEIGHT Dimensions Weight STERILIZATION CHAMBER Configuration Total Volume Shelf Material
1,760(H)×1,040(W)×1,060(D)mm 640Kg Rectangula 131.4L, 400(H)×450(W)×730(D)mm Removable Two-tired Shelf Stainless Steel
DOOR Door Type Door Control STERILANT Liquid Chemical Agent Concentration & Usage
Double Door (Pass-through, Vertical Sliding Door) by Foot sensor switch & Touch screen. Hydrogen Peroxide 10ml (50%), 1 Cycle / Cassette
CONNECTION Electricity Power Consumption
400V, 3 Phase, 50Hz or 200V, 3 Phase, 50/60Hz 4 KVA
PROGRAM Control Self-Test Mode Printer Outputs Data Storage
PLC Automatic Built-in Thermal Printer Memory Card / Network
DISPLAY Screen Alarm
8.4” Wide Touch Screen, 2EA (Both sides) Audible & Visable Alarm
MOBILITY Mobile wheels or Cart
Built-in 4 locking wheels
AIR INLET BACTERIA ETENTION FILTER HEFA Filter 99.97% Efficiency at 0.3 micron(0.3×10-6) REGULATORY APPROVALS
CE 0120 / ISO 13485 / ISO 9001
OPERATIONAL ENVIRONMENT Temperature 5 ~ 40℃ Humidity 5℃~30℃/ below 80%, 31℃~40℃/ below 50%
Universal data acquisition system Memory Card (CF, SD), USB, Ethernet ●
User Friendly interface Easy-to-use, color-coded touch screen (Both sides) ●
Spacious chamber design
Easy-to-use Sterilization Agent Free standing or wall Easy-to-use, single-use cassette type installation options ● No required additional consumables for waste system.
Removable two-tiered shelf ● Free contactable chamber wall-Error free ●
Built-in Thermal printer
●
Vertical Sliding Door System
Foot sensor switch
Built-in 4 locking wheels
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910
Consumables
Simple Convenience RENO Sterilization Agent RENO Sterilization Agent is designed for user's convenience & safety - Easyto-use load and single-use cassette type. CHEMICAL Hydrogen Peroxide (50%) 1 Cycle / Cassette USAGE ■ SHELF LIFE 12 months ■ STORAGE 2 ~ 8℃ in refrigerator ■ PACKAGING RENO-S20/S30/D50 - 20cassettes / Box ■ ■
RENO-S130/S130D - 15cassettes / Box
Chemical indicator Strip Place inside the instrument package to monitor that the instrument has been exposed appropriately by hydrogen peroxide gas. The Chemical indicator turn from RED to YELLOW after exposure to vapor hydrogen peroxide. SHELF LIFE by 2 years after date of manufacture Room Temperature (15-30℃) under dry condition. STORAGE
■ ■
Keep away from high temperature, high humidity, sterilizing agents and direct sunlight. ■ PACKAGING 250ea/Pack
Process
Chemical indicator Tape External chemical indicator tape that gives the sterilizer operator assurance that each pack or item has been exposed to the sterilization process. The Chemical indicator changes from BLUE to PINK when exposed to vapor hydrogen peroxide. SHELF LIFE by 2 years after date of manufacture Room Temperature (15-30℃) under dry condition. STORAGE
■ ■
Keep away from high temperature, high humidity, sterilizing agents and direct sunlight. ■ PACKAGING 55m/Roll ; 5Rolls/Pack
Process
RENO accessories RENOSEM offers a full line of necessary accessories for the sterilization to run RENO Series at maximum productivity.
Biological Indicator RENO SCBI (Self Containted Biological Indicator) is evidence for proper sterilization condition are achieved. Bacterial spores (Geobacillus stearothermophilus) ; Spore Population : 1.9 x 106 Spores / Unit. 24 hour incubatiion time for results Built-in Chemical Indicator ■ SHELF LIFE by 15 month from date of manufacture ■ STORAGE Room Temperature (15-30℃) under dry condition. ■ ■
Keep away from freezing, sterilization agents, direct sunlight and UV lights. Do not refrigerate. ■ PACKAGING 30EA/Box
Tyvek Pouch A wide variety of Tyvek Pouch Roll with Chemical Indicator can meet every instruments need as well as maximum value and quality. 115℃ ~ 130℃. SEALING TEMPERATURE Built-in Chemical Indicator ■ MATERIALS 2 ~ 8℃ in refrigerator ■ SIZE ˙Width - 75mm, 100mm, 150mm, 200mm, 250mm, 300mm, 400mm ■ ■
˙Length - 70m
B/I Incubator Designed to incubate biological indicator. INCUBATING TEMPERATURE INCUBATING TIME ■ ELECTRICITY ■ ■
56℃ ~ 58℃. 24 hours 110~220V, 50~60Hz
Instrument Tray Trays offer the ultimate in protection for your valuable instruments with durable materials.
Printer Paper Used for printing sterilization information in Reno-series sterilizer. Not required the additional ink. Room Temperature (15-30℃) under dry condition. STORAGE Keep away from direct sunlight and UV lights. ■ PACKAGING 16m/Roll, 5Rolls/Pack ■
RENOSEM Co., Ltd. RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea (#421-742) TEL. +82.32.624.4900
FAX. +82.32.624.4910