Reefer Guidelines and Instructions
REEFER CONTAINER VESSEL SUPPORT AND SPARE PARTS GUIDELINES AND INSTRUCTIONS
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 1
Reefer Guidelines and Instructions
Table of Contents 1.0 Reefer Malfunction Reporting......................................................... 3 1.0.1 Duty Phone..................................................................................................... 4 1.1 Acceptance & Repair of Shipper Owned Reefer Containers (SOC) ................................ 4 1.2 Repairs to reefer units of partner lines ..................................................................... 5 1.3 Cannibalization of Empty Reefers ............................................................................ 5
2.0 Ordering of Reefer Spare Parts ...................................................... 6 2.1 Allowance List....................................................................................................... 6 2.1.1 Compressor oil ................................................................................................ 7 2.2 Preferred reefer spare parts replenishment key ports................................................. 7 2.3 Reefer spare parts contacts .................................................................................... 8 2.4 Consumable parts ................................................................................................. 8 2.5 Combining orders / minimum order value ................................................................ 8 2.6 Carrier Software and Configuration Cards................................................................. 9 2.6.1 Software versions ............................................................................................ 9 2.6.2 Ordering software and configuration cards .......................................................... 9 2.7 Logman and reefer software ................................................................................... 9
3.0 Returning of Defective Parts ........................................................ 10 3.1 Responsibility ..................................................................................................... 10 3.2 Parts to be returned ............................................................................................ 10 3.3 Marking of parts to be returned and documentation required .................................... 13 3.3.1 Return Tag ................................................................................................... 13 3.3.2 Reefer Parts Return Form ............................................................................... 14 3.4 Addresses where to send return parts.................................................................... 15 3.4.1 Carrier ......................................................................................................... 15 3.4.2 Daikin .......................................................................................................... 17 3.4.3 Thermoking .................................................................................................. 17 3.4.4 Starcool ....................................................................................................... 19 3.5 Compressor Return Procedure .............................................................................. 21 3.6 Electronics Return Procedure for Carrier and Thermoking ......................................... 21 3.7 Reefer Unit Warranty........................................................................................... 22 3.7.1 Container numbers – warranty units ................................................................ 23
4.0 Superseded Spare Parts Numbers ................................................ 25 4.1 4.2 4.3 4.4
Superseded Superseded Superseded Superseded
Carrier Part Numbers ......................................................................... 25 Daikin Part Numbers .......................................................................... 26 Thermoking Part Numbers .................................................................. 26 Starcool Part Numbers ....................................................................... 27
5.0 GSMS Cross-Reference ................................................................. 28 Annex I – Reefer Parts Return Form .................................................. 29
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 2
Reefer Guidelines and Instructions
1.0 Reefer Malfunction Reporting Whenever a malfunction of, or damage to a reefer machine occurs, a reefer malfunction report (malreef) should be send. In case spare parts have been used for the repair, a workorder should be created in RDRM or MOVE in addition to the malreef. See 2.0 Ordering of Reefer Spare Parts on page 6 and 3.3 Marking of parts to be returned and documentation required on page 13. A malreef must be prepared and send by use of the RMQS (Reefer Monitoring and Quality System) application installed onboard. The output file must be attached to an email and sent to
[email protected], with no other email address in copy. Malreef follow up is done by CENEQUVSLSUP. If you have extra information that is not mentioned in the malreef: send an additional email to CENEQUVSLSUP. In addition to the above, CENEQUVSLSUP shall be informed immediately by RMQS report or email when: Assistance or guidance is required. Shortly after loading, failure or damage of the reefer machine is observed which should have been corrected during before loading. There is a failure or damage of the reefer machine which the vessel is unable to repair. The reefer machine is not fit for loading or transportation and thus to be short-shipped. Failure or damage to a reefer machine has been corrected on board, but with possible damage to the cargo. There is a failure or damage on special shipments (SuperFreezer, Cold Treatment, Controlled Atmosphere, Aqualife). When RMQS is not available or not working, send your report as normal email message using the following format: To: CENEQUVSLSUP cc: Next port of call if repair assistance is required. A1) A2) B1) B2) B3) B4) C1) C2) C3) D1) D2) E1) F1) G1) Inspection? G2)
Container number Unit type and model Temperature setting in degrees C Ventilation setting in Cbm/H Commodity Operator of specific reefer (e.g. MSL, SCL or partner line) Date when failure/damage observed Duration of malfunction or stoppage Maximum temperature deviation during stoppage/malfunction Which parts have been found defective? Alarms displayed on unit? (Active or Inactive) Action taken to bring unit back on setting temperature Repairs outstanding when container discharged Should the failure/damage have been observed during the last Pre-Trip Date and company performing last Pre-Trip
Temperatures measured on display, with external thermometer or by OHM-meter H1) Supply air temperature, for CRR-40 units both RH and LH H2) Return air temperature H3) Ambient temperature, from display or other device
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 3
Reefer Guidelines and Instructions
H4) H5)
Evaporator temperature (if available) USDA probe temperature (if available)
I1-I13 Information I1) I2) I3) I4) I5) I6) I7) I8) I9) I10) I12)
ONLY to be filled in when reporting CONTROLLED ATMOSPHERE to be taken from CA Controller Cd01 Membrane temperature setpoint (Deg. C) Cd02 Membrane input temperature (Deg. C) Cd05 Software version Cd07 Nitrogen supply pressure (bar) Cd13 Last O2 calibration span voltage in mV Cd19 Air compressor (AC) state Cd26 Oxygen solenoid state Cd27 Nitrogen purity valve state Alarms displayed CA controller? (Active or Inactive) CO2 set in % I11) O2 set in % CO2 reading I13) O2 reading
Compressor suction and discharge pressures MUST be stated. If there is no indication on the unit, measure the suction and discharge pressures with gauge set. For Super Freezer units, pressures are required for both the R134a and the R23 system. J1) Suction pressure (bar) J2) Discharge pressure (bar) K1) Does the defrost operation seem normal, if not please advise any abnormality. L1) Any useful comments M1) If any assistance required from the next port of call.
1.0.1 Duty Phone Maersk Line has two mobile duty phone numbers which can be called at any time of the day for assistance/guidance on reefer matters. Only use these numbers in case of emergency when all other options have been tried. Technical assistance for vessels at sea (CENEQUVSLSUP) Located in Singapore (UTC+8) Phone no. +65 631 83 632 Operational assistance (CENSALREFTEC) Located in Copenhagen (UTC+1) Phone no. +45 40 52 47 39 • Rejecting of containers loaded with failures • Discharging of containers with failures • Controlled Atmosphere: CO2 supply and injection For questions about reefer settings (temperature, ventilation, humidity), contact the agent in the port of loading.
1.1 Acceptance & Repair of Shipper Owned Reefer Containers (SOC) To be accepted on a Maersk Line vessel, a SOC reefer container must have: • a valid CSC plate permanently affixed to the container;
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 4
Reefer Guidelines and Instructions
•
an unique and legible container number permanently attached to the container. This unique container number must preferably be a composition of a four letters prefix and seven numbers.
A full spare parts kit, including repair manuals and electric diagrams, must be supplied to Maersk Line by the shipper. The kit must follow the container throughout the voyage and be delivered to the consignee with the container. If the reefer unit/container is not identical to Maersk Line own reefers and no proper spare parts or a valid LOI (Letter of Indemnity) is provided prior to vessel departure holding Maersk Line free of any responsibility towards breakdowns, repairs, etc. the booking office in charge must forward a pre-advise notice to the vessel(s) loading a shipper owned container advising them when a LOI is replacing the supply of spare parts. Failure to do so will result in rejection of the unit by the vessel. All settings, such as temperature/ventilation/humidity, must be in line with Maersk Line inhouse guidelines. No shipper-owned containers will be accepted with a temperature setting below -22°C (-8°F). A shipper-owned container will not be accepted in hot stuffed condition. Maersk Line is to be indemnified for all loss/claim/damage to cargo requiring special heating/cooling in the event of malfunction while in Maersk Line custody. Clause 10 & 12 of the Maersk Line B/L refers in the event the Shipper is to be held liable for any damages/cleaning costs and will be invoiced for all repairs, including spare parts, if not supplied by the Shipper. If any malfunction occurs then it is only required to repair in the extend possible and what available spare parts allows. Repairs involving ML spare parts to be approved by
[email protected]. When a repair has been performed to a SOC reefer unit, send a malreef report and spare part order as per procedures for Maersk Line reefers. Please see RAOM (Reefer Acceptance and Operational Manual) for additional information regarding SOC reefers.
1.2 Repairs to reefer units of partner lines When a repair has been performed to a reefer unit of a VSA partner line and spare parts have been used, send a malreef report and spare part order as per procedures for Maersk Line reefers.
1.3 Cannibalization of Empty Reefers Only in case of emergency, empty reefers may be cannibalized. CENEQUVSLSUP must always be notified accordingly with container numbers and part defective. The defective part must be installed in the empty reefer and the container should be labeled with vessel name, date and part defective. A reefer malfunction report must be send as per normal procedures.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 5
Reefer Guidelines and Instructions
2.0 Ordering of Reefer Spare Parts The replenishment Spare Part must be ordered through the ship purchasing system. For reefer spare parts, Maersk Line uses two systems, RDRM and MOVE. The vessel creates the requisition in the system, which must contain spare parts for reefer units only. When a repair has been made to a reefer unit with the use of a spare part, a workorder must be entered in the RDRM or MOVE system. The spare part used must be placed under the correct STS repair code where the part actually has been used. For example: Two repairs have been made on one unit, compressor has been replaced and so has the condenser motor. Compressor part nr. must be placed under code X711 and condenser motor part nr. under code X521. Parts for different kind of repairs must never be placed under same code unless they are part of same repair. For example: a filter/drier can be place under code X711 because it must also be changed when the compressor is replaced. When the workorder is completed the parts stock is automatically updated. To order the parts used, create a requisition in the system. The requisition to be created in RDRM or MOVE under purchase type: "Reefer parts" and account no. B.2603925 The requisition must always contain following information: • Delivery port - select port of delivery from list of key ports, see below. • Part number • Article number • Description • Current stock • Requested delivery date The requisitions must be submitted no later than 8 working days before the requested delivery date. Order confirmations are issued from the purchase department. In case of back orders from the suppliers the orders are cancelled in the APM-M purchase system and vessel is informed accordingly. New requisition must be created by vessel. Upon receipt of ordered parts C/E must update RDRM or MOVE accordingly.
2.1 Allowance List Vessels equipped with more than 700 plugs are allowed to have on board a X-Large Kit and Super Freezer Kit. Vessels with 300 to 700 plugs are allowed to have on board a Large Kit and Super Freezer Kit. Vessels with 150 to 300 plugs are allowed to have on board a Small Kit. Vessels with 50 to 150 plugs are allowed to have on board a Mini Kit. Super Freezer Kit placed on board upon request by CENSALREFULT. Vessels with max. 72 hours between port calls will not be supplied with reefer spare parts.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 6
Reefer Guidelines and Instructions
Each of above kits will include manuals and tools. Vessels with PTI kits please be guide of above and add parts in PTI kit to your allowance (already done in RDRM). The allowance list for your vessel can be found in RDRM or MOVE, or received per email request to
[email protected] Remote Monitoring System Vessels not equipped with "remote monitoring system" please do not order RRM modems. Water cooling Vessels without connections for "Water cooled operation" in cargo holds please do not order spares for water cooled receivers.
2.1.1 Compressor oil Please note that compressor 18-10129-20SV and compressor 18-00055-20RM2, are delivered without lub. oil. Any delivered reefer ester oil can be used as e.g. Castrol Icematic SW-20, MOBIL EAL22R ARTIC. OIL for Scroll compressors. Use Carrier part no 07-00427-00P12, art no 414634 Oil, 32ST, for Daikin, Thermo King and Carrier scroll compressors. OIL for Thermo King and Carrier piston compressors. Use Carrier part no 07-00292-00, art no 270628, Castrol, Lub Oil R-134a, for Thermo King and Carrier piston compressors. OIL for Starcool compressors. Use Starcool part no 818667B, art no 423053,
2.2 Preferred reefer spare parts replenishment key ports The following key ports shall be selected for delivery of reefer spare parts. Spare parts are available from all suppliers in below ports you must however try to place your orders as per below. Europe • Rotterdam • Antwerp • Zeebrugge • Algeciras South America • Panama • Montevideo North America • All US main ports (prefer NWK, LSA) Middle East • Dubai Far East • Tanjung Pelepas
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 7
Reefer Guidelines and Instructions
• Singapore • Hong Kong Oceania • Sydney Africa • Cape Town The ports above are key ports where we have full DDU coverage. All other ports will generate freight charges from one or more shippers.
2.3 Reefer spare parts contacts Questions with regard to reefer spare parts shall be issued to:
[email protected] If the vessel spare part requisition system is down, spares can be ordered via telex or email. To ensure smooth expedition the requisition must always contain the below mentioned information and following set up must be used: 1. Vessel number: 2. Vessel name: 3. Date of delivery: 4. Port of delivery: Qty. Article Part Description Stock number. number. Requisition to be sent to:
[email protected] Do NOT send the requisition as attached file.
2.4 Consumable parts Consumable parts, such as plugs and cable splices can be ordered in the same way as other reefer spare parts. The distribution of these parts is done by Carrier, so the parts have a Carrier part number in the systems and allowance list.
2.5 Combining orders / minimum order value We have been advising and encouraging all vessels whenever we have opportunity to combine orders in one request, instead of ordering only one item at a time. This is in order to save shipping costs, frequent local delivery charges and to avoid the risk of losing parts. The minimum order amount of reefer spare parts to be ordered per manufacturer is 100 USD for the same reasons. Maersk Line will be responsible for the shipping costs incurred from each supplier if the order is less than 100 USD, not to mention that the shipping cost will highly exceed the part value. Some items (like fuses) cost less than 1 USD per piece.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 8
Reefer Guidelines and Instructions
2.6 Carrier Software and Configuration Cards 2.6.1 Software versions ML2 software card with Rev 1207 shall be used whenever controller ML2i is used in a ML2 unit. ML2i software card with Rev. 5x43 (x = 1 or 3) or later shall be used if your spare controller has an older version. When software version 5x43 or later is used Defrost setting must be set to AUTO. NOTE: Upon request, software cards can be updated in the following ports: ALR, TPP, PAN, HKG and CHL. Please send your request to
[email protected] minimum five working days in advance. Alternatively, CENEQUVSLSUP can also email you the latest software version to update your cards with yourself.
2.6.2 Ordering software and configuration cards Software and configuration cards are not to be ordered via the purchasing system. Instead, please order replacement cards by email to
[email protected] When new updated cards are received onboard, the old version cards must be returned to: Maersk Line Center Equipment – Maintenance and Repair Att: CENEQUVSLPUR Boompjes 40 3011 XB Rotterdam The Netherlands Carrier OMNI drive and SRAM card for ML3 controller and adapter for ML2i controller. Shall be ordered by email to:
[email protected] Do not attempt to use ML2/ML2i flashcard in a ML3 controller.
2.7 Logman and reefer software Logman can be ordered by email to
[email protected] All other questions about Logman and reefer unit software can be addressed to
[email protected]
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 9
Reefer Guidelines and Instructions
3.0 Returning of Defective Parts 3.1 Responsibility It is the responsibility of the Chief Engineer that all parts with a core value are returned to the manufacturer according to manufacturer’s guidelines. NOTE: The policy of the manufacturers is "NO PART NO PAY". Defective parts must be delivered to the agent upon receipt of the new part. Thus the agent must be informed in due time in order to arrange pick up. See 3.3 Marking of parts to be returned and documentation required on page 13. All parts returned should be labeled with a Return Tag. Thermoking and Starcool have their own Return Tags, use a Maersk Return Tag for parts of all other manufacturers. Wrap the part in the original packing. The information on the Return Tag is very important when warranty claims have to be filed. This information is also needed on the Maersk Line “Reefer Parts Return”.
3.2 Parts to be returned The following parts must be returned to reclaim core and / or warranty payment. Rewinding of condenser and evaporator fan motors is not done; these motors do not need to be returned if they are not mentioned in the table below, unless the unit is still under warranty. Parts should also be returned if they still have parts warranty (normally 1 year). See 3.7.1 Container numbers – warranty units on page 23 for a list of container number series that are still under warranty. Article number 244716 344300 354733 354734 356650 374647 412348 439289 316996 331984 336545 350317 356546 357853 425343 425344 426682 340413
CENEQUVSLPUR Revision 1.5 Jan 2009
Part number
Description Carrier 18-10129-20SV Compressor, R-134A, Blue M12-56002 Controller, ML2 & ML2i M12-00329-00RB Hi-Voltage module ML2 M12-00433-00RB Display module ML2 / ML2i M-56008 ML3 MPC, Controller 18-00055-20RM2 Compressor R-134a Rebuild, Gray 18-10134-23 Compressor scroll 18-10136-20 Compressor Thermoking 8102-743 Compressor, TNE-508/CRR40 45-2009 MP3000A Controller 45-2010 Main Relay Board MP3000A 451898R Modem, RMM 102-795 Compressor Scroll, Magnum 8214-011 Modem RMM, for Daikin/Carrier/Starcool 45-1853 Output module 45-1949 Micro P.D. controller 45-1806 Power Module PCB 102-796 Scroll compressor, R-23 Superfreezer
Page 10
Reefer Guidelines and Instructions
415022 415023 415026 439725 439726 439727 439728
814242C 814658B 818511B 818255C 818515A 818517A 818527B
356412 356415 356416 356417 356418 356419 356420 356421 356423 356424 356425 356426 356427 356543 356544 356545 356616 356617 356629 356630 356863 356866 356870
1315426 0955287 1241361 0954936 1602656 1587942 1587959 1241378 1198931 1198917 0979447 0030652 1511301 0991050 1736650 1497931 1498035 1270390 0980618 0329679 0983338 1241493 1256495
356873 356890
138143J 1266339
Starcool Frequency converter, complete Compressor Power meas PCB Controller Module Display PCB Led PCB Keypad Daikin Compressor scroll Coil (ISV, HSV, DSV, BSV, ESV, LSV) Discharge Pressure Regulator Fan motor, condenser Fan motor, evaporator Low pressure transducer, LPT High pressure transducer, HPT High pressure switch, HPS Magnetic contactor, EFL/H & CFC Compressor contactor Control transformer, TrC, 415-24/13V Controller fuse, 250V, 10 amp. Evaporator fan blade PT/CT board PCB ass'y CPU & I/O Board Expansion valve for economizer pipe Fusible safety plug Coil, Suction Modulating Valve Condenser fan blade Reverse phase protector, RPP Suction Gas Sensor Phase correction contactor, PCC Body, Electronic Expansion Valve Coil, Electronic Expansion Valve incl. Lead Wire Lead wire, electronic expansion valve
Daikin units are covered by a maintenance cost program and all replaced parts must be landed upon receipt of the new part with filled in Return Tag safely attached. Daikin parts are to be addressed to Daikin per address of local agent in landing port. The agent will keep the parts in stock for 90 days for inspection by Daikin where after parts are destroyed. Please return Daikin spare parts in key ports and preferably in Rotterdam or Algeciras. NOTE: Electronic parts and compressor motors that are covered by warranty or represent a core value are delivered on exchange base; this means that the defective part must be handed over upon receipt of the new part. Vessel must return the part no matter if it is burned or otherwise damaged. York RMM Modems (used in Carrier, Daikin and Starcool units) are not to be returned. Thermoking modems do have to be returned, see the table above. Empty refrigerant bottles that can not be refilled do not need to be returned. Refillable refrigerant bottles can be returned without further notice. CENEQUVSLPUR Revision 1.5 Jan 2009
Page 11
Reefer Guidelines and Instructions
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 12
Reefer Guidelines and Instructions
3.3 Marking of parts to be returned and documentation required Whenever a repair is done to a reefer unit and return parts have been used, the following documentation should be completed: • Reefer malfunction report (malreef) – see 1.0 Reefer Malfunction Reporting on page 3; • Create a workorder in RDRM or MOVE (if available on board); • Return Tag to be attached to the defective part; • Reefer Parts Return form (I-form 138) to be sent. The agent in the port of landing should be informed at least 24 hours in advance in order to arrange the collection of the parts. Specifically for Rotterdam: Reefer parts are to be landed separately from other return goods (ship spares etc.). Reefer parts and refrigerant bottles are collected via the agent and must be requested 24 hours before the ETA. Carrier and Thermoking electronic parts should be tested before returning to manufacturer. Please see the appropriate procedure in 3.6 Electronics Return Procedure for Carrier and Thermoking on page 21.
3.3.1 Return Tag All parts returned must have a completed Return Tag safely attached to them with tape or string. Please ensure the tag attached to compressors is secured in a waterproof way. Thermoking and Starcool have their own Return Tags, use a Maersk Return Tag for parts of all other manufacturers. Wrap the part in the original packing. The information on the Return Tag is very important when warranty claims have to be filed. This information is also needed on the Maersk Line “Reefer Parts Return” form (I-form 138). To order Maersk Line Return Tags, use part number 358257. Thermoking and Starcool include their own Return Tag in the packing of the new part. It is very important that all fields are completed correctly; otherwise the warranty or core request will be rejected by the manufacturer. Maersk Line Return Tag Advice note no: please state vessel number CA - consecutive number. CA indicates reefer spare part. For example: mv. Sealand Florida, 5th dispatch of defective reefer parts: 336 - CA - 05 Container no. : MHHU5627841 Unit serial no. : Old part serial no. : New part serial no. : Cause of failure :
FCY80039851 4008847 410513 Controller defect
Advice no. 336 CA 05 Date: 02-0118
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 13
Reefer Guidelines and Instructions
Thermoking Return Tag In section "DEALER CODE" enter M2400 and in section "REF.NO." state advice note number (ship code - CA - consecutive no.). For example: Dealer code : M2400 Ref.no. / Core req. no. : 336 – CA - 05 Part no. Quantity Packing list no. Unit serial no.
: : : :
845 -1909 1 1 039AJ0522
Container/Equipment : ID MCWU6658581/17LD658411 Please do NOT fill in section for Warranty or Core field. Warranty Core Starcool Return Tag In section “Repair Shop” enter your vessel code and name. For “Country” use “Vessel”. For example: Repair Shop : 336 / Sealand Florida Repair date Country
: 2008-11-23 : Vessel
Supervisor Container ID Unit No.
: John Doe / Chief Engineer : MSWU0017252 : 039AJ0522
Item No. Item Name Old Part Serial No. New Part Serial No.
: : : :
818511B Power Meas. PCB 8546489 9985472
Alarm code
: AA427
Failure description
: Incorrect line voltage measured.
3.3.2 Reefer Parts Return Form The "Reefer Parts Return" form (I-form 138) should be made in three copies. Please attach one copy to the part returned, forward one copy to
[email protected], and keep one copy for your own administration. The form is used to ensure the parts are send to the correct address and to claim core and warranty payments with the suppliers. It is important that all information is entered accurately.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 14
Reefer Guidelines and Instructions
Because parts are returned to the manufacturer, the receiver address will be different for each manufacturer. Therefore, a separate form must be used for parts of each manufacturer. More than one part of the same manufacturer can be entered on the same form. If for some reason the I-form can not be used, an Excel form is available from CENEQUVSLPUR on request. Please use the following guidance to fill in the Reefer Parts Return form: Advice note no: please state vessel number - CA - consecutive number. CA indicates reefer spare part. Use the same number as entered on the Return Tag. For example: mv. Sealand Florida, 5th dispatch of defective reefer parts: 336 - CA - 05 Return identity: State vessels name. Name & Address of Agent: Name of agency that collects the parts. Name & Address of Receiver: Name of manufacturer and address where parts must be forwarded to. Total No of package: Amount of package. Total weight: Total weight of shipment. Check the correct box for Reason Returned and Maker field. Fill in all parts returned in the same shipment in the appropriate sections, for example: Container no. Unit serial No. Qty. Part no. Description Serial no. 1 8102Compressor 3DSTA-TFD-253 MWCU6196468 039A9J0522 743
3.4 Addresses where to send return parts 3.4.1 Carrier Whenever possible please land return parts in Rotterdam, Algeciras, Hong Kong, Singapore, Tanjung Pelepas or Yokohama. Electronic parts must be tested before returning to the manufacturer, please see the separate procedure at the bottom of this document. Please address the parts to the nearest Carrier distribution centre: Europe:
Carrier Transicold Ltd. Attn.: Receiving Department Pittsburgstraat 21 3047 BL Rotterdam The Netherlands
USA: (West Coast)
Carrier Transicold Attn: C.R. Higginbotham 4450 Tidewater Ave. Oakland, CA 94601 USA
(East Coast)
Carrier Transicold Carrier Parkway Syracuse, NY 13221 USA Carlyle Compressor Remanufacturing
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 15
Reefer Guidelines and Instructions
1699 Litton Street Stone Mountain, GA 30083 USA This address is for returning Compressors ONLY for vessels that do not call in the Far East or Europe. Panama:
Carrier Transicold Panama Calle E, Final (Paseo Gorgas) Edif. 29, Local No. 4. Zona Libre de Colon Republic of Panama
Chile:
Carrier Transicold Chile Av. O’Higgins 2767 San Antonio Chile
Uruguay:
Satelir S.A. Cno. Maldonado KM.17.500 - Local 213 Zonamerica Montevideo Uruguay
Brazil:
Carrier Transicold Brazil Rua da Cinstitucao Cep 11015-471 407 Barrio Paqueta Santos, SP Brazil
Australia:
Carrier Refrigeration Operations Building A, Lot 302 Hill Road Lidcombe Sydney, NSW 2141 Australia
NZ:
Transcold Industries Ltd. 38 Oakliegh Ave. Takanini Auckland New Zealand
Japan:
Carrier Transicold (Japan) Ltd. 308, Y-Cc, Daikoku-Futo Tsurumi-Ku Yokohama 230-0054 Japan
Korea:
Expeditors Korea Co. Ltd. Korea G.W. Logistics Co. Ltd. 438-1, Jwasam-Ri Sangbuk-Myun Yangsancity Kyungnam
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 16
Reefer Guidelines and Instructions
Republic of Korea Hong Kong:
Singapore:
South Africa:
Carrier Refrigeration (Hong Kong) Ltd. Unit A-B 20/F, Tsuen Wan International Centre 58-70 Wang Lung Street Tsuen Wan New Territories Hong Kong China Carrier Refrigeration (Singapore) PTE, Ltd. Attn: Parts return 251 Jalan Ahmad Ibrahim Singapore 629146 Carrier Transicold Ltd South Africa 1 Ruco Park Boston Circle Airport Industria Cape Town 7525 Republic of South Africa
3.4.2 Daikin Whenever possible please land return parts in Antwerp, Rotterdam, Algeciras, Singapore, Tanjung Pelepas, Hong Kong or Yokohama. The parts will not be physically sent back to the manufacturer, but must be stored by the agent for 90 days for inspection by Daikin. After this, they will be disposed. Thus, for Daikin parts, the return address is "AGENT STORAGE 90 DAYS". Since Daikin is entitled to inspect the parts, the same documentation as for other suppliers is required; including the return tag to identify the origin of the parts.
3.4.3 Thermoking Whenever possible please land return parts in Antwerp, Rotterdam, Algeciras, Singapore, Tanjung Pelepas, Hong Kong or Yokohama. Electronic parts must be tested before returning to the manufacturer, please see the separate procedure at the bottom of this document. Please address the parts to the nearest Thermoking distribution centre: Europe:
Thermo King Container Antwerp Attn.: M2400 Wilmingtonstraat 3 Haven 500 2030 Antwerp Belgium
USA:
Thermo King Corporation 314 West 90th Street Minneapolis
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 17
Reefer Guidelines and Instructions
Minnesota 55420 USA Panama:
TK Trading Co. c/o Thermo King Container Parts (Free Zone) Inc. Via Simon Bolivar (Transistmica) El Ingenio Enfrente Sears Panama City 9A Republic of Panama
Chile:
TK Trading Co. c/o Hussman Region Andina Ltda. Av. Americo Vespuci N 2568 Conchall, Santiago Chile
Brazil:
Thermoking do Brasil Ltd. 2109-8906/2109-87 Alameda Caiapos 311 Barueri, Sao Paulo Brazil
Japan:
TK Trading Corporation c/o Japan Schenker Co. Ltd. 18 Daikoku Futo Tsurumi-ku Yokohama 230 Japan
Hong Kong:
TK Trading Corporation c/o Kerry Godow (Kwai Chung) 10/f, 4-6 Kwai Tai Road, Kwai Chung, N.T. Hong Kong
Singapore:
TK Trading Corporation c/o Senteng Marine Service Pte Ltd No. 71 Ubi Crescent #02-01 Excalibur Centre Singapore 408571
Australia:
Australian Container Parts Unit 12, 71a Rhodes Street Hillsdale Sydney NSW 2036 Australia
NZ:
TK Trading Co. TK New Zealand 8 Langley Road Manakau City Auckland New Zealand
U.A.E.:
TK Trading Co.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 18
Reefer Guidelines and Instructions
c/o Refrigerated Transport Systems LLC Warehouse No.9 Al Ramool, 215/18 street Al Rashidiya Dubai U.A.E South Africa:
Thermo King Trading c/o Jack Agencies cc No. 19 Montague Park Stela Road Montague Gardens Cape Town South Africa
3.4.4 Starcool Whenever possible please land return parts in Rotterdam, Algeciras, Hong Kong, Tanjung Pelepas or Yokohama. Please address the parts to the nearest Starcool distribution centre: Denmark:
Starcool Bjerndrupvej 47 6360 Tinglev Denmark
Spain:
Containers Del Mediterraneo S.A. Poligone Industrial Cortijo Real, Parcela J-4 11206 Algeciras (Cadiz) Spain
USA: (West coast)
Martec International 9080 Rosecrans Avenue Bellflower, CA 90706 USA
(East coast)
Martec International 529 Dowd Avenue Elizabeth, NJ 07201 USA
Panama:
Maersk Panama S.A. Calle Diablo Edificio 42 Balboa 0833-0207 Plaza Panama Balboa Panama
Chile:
Container Operators S.A. Avenida Las Factorias 8150 Malvilla San Antonio Chile
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 19
Reefer Guidelines and Instructions
Uruguay:
Montevideo Port Services S.A. Planir, Deposito 24 Puerto de Montevideo 12000 Montevideo Uruguay
Hong Kong:
Brigantine Services Ltd. 48 Wang Lok Street Yuen Long Industrial Estate Yuen Long, N.T. Hong Kong
Malaysia:
Pelepas-Brigantine Container Service PTP Free Zone Area Jln. Pelabuhan Tg. Pelepas 81560 Gelang Patah Johor Malaysia
Australia:
Feliba PTY Ltd. Unit 2, 19-23 Paramount Road West Footscray, Victoria 3012 Australia
NZ:
ReeferTech (NZ) Ltd. 29 Aicken RD Road 3 Papakura Auckland 2583 New Zealand
U.A.E.:
Blue Water Shipping LLC P.O. Box 17797 Jebel Ali United Arab Emirates
Oman:
Salalah Port Services Co. (S.A.O.G) P.O. Box 369 Salalah P.C. 211 Sultante of Oman
South Africa:
S.A.T.I. Container Services 4 Sati Road Potsdam 7441 Cape Town South Africa
Do not hesitate to contact
[email protected] in case you have any doubt where to address or land defective parts.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 20
Reefer Guidelines and Instructions
3.5 Compressor Return Procedure To qualify for core credit the core must have the following: 1. Consist of all original parts and be fully assembled. A complete compressor includes cylinder heads and valve plates, crankshaft cover, oil base, oil pump and all hardware. 2. Core is sealed, including; suction and discharge ports and all port fittings (use covers from the new compressor or cover ports with duct tape). 3. Not damaged by no-operational causes such as rough handling, fire, or improper installation and dismantling procedures. Place the core in the shipping carton used to ship the new compressor or secured (strapped or bolted) to a pallet.
3.6 Electronics Return Procedure for Carrier and Thermoking All Carrier controllers and Thermoking main relay boards (mrb) and controllers are to be returned. The controllers and mrb have to be tested first before returning to the manufacturer. When completing the return form the address of the nearest Carrier or TK depot has entered in the receivers field. For the Name and Address of Agent field, the nearest of the following addresses should be used: Belgium: Star Containers Attn. mr. K de Vos Nieuwe Westweg 5 B 2040 Antwerp Belgium Netherlands:
Star Containers Attn. mr. S. Singh Gebouw 17 Coloradoweg 50 3199 LA Maasvlakte RT The Netherlands
Spain:
Maersk Espana SA Attn. mr. D.Luque Muelle Juan Carlos I,s/n Puerto de Algeciras 11201 Algeciras (Cadiz) Spain
South Africa:
J D Ship Services Attn. mr. J.Watson 23a Paarden Island Road Paarden Island, 7405 Cape Town South Africa
Australia:
Feliba Pty Ltd Attn. mr. R.Nilsson Unit 3/ no1 Perry Street Matraville, NSW 2036 Australia
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 21
Reefer Guidelines and Instructions
USA: (East coast)
Maersk Equipment Service Co. Attn. mr. R.Pritchard 5080 McLester Street Elizabeth, NJ 07207 USA
(West coast)
Maersk Equipment Service Co. Attn. Ms.C. Bouchard Building 400 Parts Room 2500 Navy Way Terminal Island, CA 90731 USA
Panama:
Maersk Panama SA Attn. Mr. J.Duncan Avinida Arnulfo Arias Madrid Puerto de Balboa, Edificia 1501, 1er piso Panama Republic of Panama
Uruguay:
Montevideo Port Services SA Attn. mr. S. Freita or Mr. J. Fernandez Cno. Burghi s/n esq. Cno. Cibils. CP 12800 Montevideo Uruguay
NOTE: Electronic parts and compressor motors which either are covered by warranty or represent credit core are delivered on exchange base, this means that the defective part must be handed over upon receipt of new part. Vessel must return part no matter burned or otherwise damaged.
3.7 Reefer Unit Warranty Information on all parts on Maersk Line reefer units covered by warranty can be found on the data / serial plate on the unit or part. It is a request from manufacturers that the following information is available when warranty claims are presented: 1. Unit serial number (FROM DATA PLATE ON UNIT) 2. Unit model number (FROM DATA PLATE ON UNIT) 3. Commissioning date (FROM DATA PLATE ON UNIT) 4. Part no and description of part 5. Serial no of old part (if available) 6. Serial no of new part 7. Cause of failure. Makers have tightened up procedures and in some cases rejected warranty claims that do not have above-mentioned information. Therefore once again, it is of the utmost importance that the workorder / malreef / Reefer Parts Return form has the above-mentioned information. In case the information is not available, please fill in 'NA' instead of the requested information.
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 22
Reefer Guidelines and Instructions
3.7.1 Container numbers – warranty units Prefix
Number
Year built
GMP
UNIT
COMPRESSOR
MOTORS
MWCU
6813596-6816580
2004
24 mth
42 mth
42 mth
MWCU
681659-682358
May 2005-Jun 2005
24 mth
42 mth
42 mth
MWCU
682359-683360
Jun 2005-Aug 2005
24 mth
42 mth
42 mth
MWCU
682421-683709
Jul 2005-Aug 2005
24 mth
42 mth
42 mth
MWCU
6840009-6856999
2005
60 mth
60 mth
60 mth
MWCU
6857001-6873996
2005
60 mth
60 mth
60 mth
MWCU
6874009-6883994
2005
60 mth
60 mth
60 mth
MWCU
5200007-5219996
Jan 2006-Apr 2006
60 mth
60 mth
60 mth
MWCU
5220003-5232093
Oct 2006-Dec 2006
60 mth
60 mth
60 mth
MWCU
5232107-5232771
2007
60 mth
60 mth
60 mth
MWCU
5232787-5252090
Oct 2007
60 mth
60 mth
60 mth
MWCU
5252103-5272096
2008
24 mth
36 mth
36 mth
MWCU
5272100-5282094
2008
24 mth
36 mth
36 mth
MWCU
5282108-5287096
2008
24 mth
36 mth
36 mth
MWCU
5287100-5292092
2008
24 mth
36 mth
36 mth
MWCU
5292106-5308096
2009
24 mth
36 mth
36 mth
MWCU
5740509-5750390
Jan 2006-Feb 2006
60 mth
60 mth
60 mth
MCAU
8565857-8570848
2007
60 mth
60 mth
60 mth
PONU
480100 - 488599
2002
2006
2009
2006
PONU
287650 - 293749
2002
2006
2009
2006
PONU
497850 - 499599
2004
2009
2011
2011
PONU
450800 - 452049
2004
2009
2011
2011
MNBU
0000004-0003997
2008
24 mth
36 mth
36 mth
MNBU
0004000-0013995
2008
24 mth
36 mth
36 mth
MNBU
0014008-0027999
2009
24 mth
36 mth
36 mth
UNIT
COMPRESSOR
MOTORS
MWCU
6900005-6929992
2004
x
2 year
2 year
2 year
MWCU
6930000-6944997
2005
x
2 year
2 year
2 year
MWCU
6945000-6956998
2005
x
2 year
2 year
2 year
MWCU
6957000-6959997
2005
x
2 year
2 year
2 year
MWCU
6960004-6966996
2005
x
2 year
2 year
2 year
MWCU
6967009-6969941
2005
x
2 year
2 year
2 year
MWCU
6980000-6994998
2005
x
2 year
2 year
2 year
MWCU
6995000-7004997
2006
x
2 year
2 year
2 year
MWCU
7005000-7009999
2006
x
2 year
2 year
2 year
PONU
293750 - 295749
2002
2007
2009
2009
PONU
488600 - 489599
2003
2008
2010
2010
PONU
295750 - 297749
2003
2008
2010
2010
PONU
489600 - 491099
2003
2008
2010
2010
PONU
491100 - 492499
2004
2009
2011
2011
PONU
492500 - 495099
2004
2009
2011
2011
PONU
495100 - 495599
2004
2009
2011
2011
PONU
495600 - 496599
2004
2009
2011
2011
PONU
496600 - 497849
2004
2009
2011
2011
PONU
450050 - 450799
2004
2009
2011
2011
Carrier
Daikin
CENEQUVSLPUR Revision 1.5 Jan 2009
Warranty
Page 23
Reefer Guidelines and Instructions
Starcool
UNIT
COMPRESSOR
MOTORS
All
All
All
2 year
2 year
2 year
UNIT
COMPRESSOR
MOTORS
MSFU
8567488-8568720
2005
2 year
3.5 year
3.5 year
MSFU
8568735-8569979
2008
2 year
3 year
3 year
Thermoking
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 24
Reefer Guidelines and Instructions
4.0 Superseded Spare Parts Numbers 4.1 Superseded Carrier Part Numbers Article No:
310454
Description: 3" Silver duct tape, box 16pcs BTL leak finder or use soap water
310175
Control transformer, ML2
10-00332-21SV
10-00332-20SV
350303
Contactor, auxiliary
10-00431-02
10-00333-02
310176
Contactor,cond. 12 Amp Compressor contactor ML2 30Amp
10-00431-06
10-00333-00
10-00431-07
10-00304-33SV
10-00333-01
66-U1-9251
10-00439-00
69NT43-397-1
69NT43-397
10-00366-01SV
12-00306-01
12-01090-00
12-00306
12-00306-00
94846
325200 314597 120413 310252
Current Sensor ML2i Sensor,STS-SRS-RTS.pt-100 ML1
Part Number:
Old P/N 1:
02-50009-00
00-9000
07-50017-00
SNOOP LEAK D
Old P/N 2:
Old P/N 3:
Old P/N 4:
Old P/N 5:
Old P/N 6:
10-01147-33
66-U1-6331-1
10-00333-01
10-00431-00
12-00309-00
66-U1-6942-6
317510
HP, switch, ML 2 Software Card ML2 / DO NOT ORDER
12-00330-xx
12-00396-00
412337
Transducer, Press
12-00352-07SV
12-00352-07
12-00352-00
311839
Sensor, STS,RTS, ML2 Config. Card ML2/ML2i / DO NOT ORDER
12-00395-01SV
12-00380-00SV
12-00278-04SV
12-00278-00
12-00402-xx
12-00357-xx
310270 313907
12-00495-02SV
12-00495-20
12-00305-05
12-00305-02
414780
Thermistor sensor, DTS, ML2 SRAM Card for use with Omnidrive
12-00594-23
12-00594-09
12-00594-18
12-00594-22
134589
Sensor, thermistor
12-01104-00
12-01091-00
12-01104-01
135542
Discharge Gauge
12-01125-01
12-01125-00
12-01125
342593
Valve Pressure Regulator
14-00204-03
14-00204-02
209619
Coil, suct. Valve, ALCO
14-00230-24SV
14-50027-00
412341
Economizer TXV
14-00232-31
14-00232-08
14-00232-30
343626
TXV, R-134a semi hermetic Stepper Motor Assy, 51130X TX Valve Hermetic 69NT40511-3xx
14-00244-42
14-01104-42
14-01104-12
14-01104-10
14-00263-20
14-00263-00
14-00273-08
14-00273-01 14-50010
504-734
330834 335953 245496
283320
Coil, suct. Valve, Sporlan Coil for Economizer Solenoid Valve Kit, Suction Modulation Valve Coil, suction modulation valve Filter drier R-12/R-134a (61-156)
14-50311-02SV
61-156
66-9015
360-56638-00
106593
Terminal, (5) Pin
17-40093-06
17-40093-02
17-40093-04
17-40112
244716
Compressor R-12 / R-134a, Blue , single voltage
18-10129-20SV
18-00055-20SV
18-00048-20SV
18-00043-06SV
18-10128-20
106488 204201 107093
412348
14-01091-02
14-01091-02
14-01091-04
14-01091-01
14-50021-01
16-00554-00
14-50021-02
66-U1-8045
18-10134-23
18-10134-21
101389
Scroll service compressor Power plug ( box with 10 pce )
22-02378-00
K25-20474
100889
Power Cable Roll 300ft
22-50348-00
22-01551-01
277721
Power Cable Splice kit
22-50350-00
3M-splice
170747
Fan condenser 17 1/2"
38-00527-02
38-00510-00SV
310052
38-00585-00
38-00503-00
314596
Fan Condenser Motor evap. For ML2I ML3 & EliteLine
54-00585-20
54-00548-00
54-00521-01
106844
Motor condenser
54-00586-20
54-00549-00
54-00541-00
354845
PTI stickers 1000 pcs
205788
Screw retaining
62-90819-00 66-U1-68118P06
VSLPTI 66-U1-681110P06
CENEQUVSLPUR Revision 1.5 Jan 2009
K26-10795
06dr2419cc06 40
22-01551-00
38-00510-00
38-00144-00
54-00516-00 / SV
54-00132-00
Page 25
Reefer Guidelines and Instructions
310253
Circuit Breaker 25Amp. (CB1)
344300
Modem RMM, For Carrier, Daikin and Starcool units Hi-voltage module, ML2, rebuilt Display module ML2/ML2i, repaired Controller ML2 & ML2i & CA, Unconfigured
356650
ML3 MPC (controller)
357853 354733 354734
66-U1-7842-13
66U1-7842-4 M12-002754SVRB
8214-011 M12-0032900RB M12-0043300RB
12-00329-00
12-00275-04SV
8214-007
8214-001
M12-56002
12-00333-03
12-00333-00
12-00301-00
12-00433-00
12-55458-00
12-00425-00
12-00386-00
12-00379-00
M-56008
12-55006
12-55008
8214-006
M12-56458-00
12-55002
4.2 Superseded Daikin Part Numbers Article No:
Description:
Part Number:
Old P/N 1:
356412
Scroll Compressor
1315426
1199415
356418
Fan Motor, Evaporator
1602656
0807333
356419
Low Pressure Transducer (LPT)
1587942
356420
High Pressure Transducer (HPT)
356544
356873
Old P/N 2:
Old P/N 3:
1463983
0512666
0797241
1587959
1463976
0512659
0797234
CPU & I/O Board
1736650
1507597
1519590
1573068
Coil, Electronic Expansion Valve incl Lead Wire
138143J
1299601
0954619
1524150
Old P/N 4:
Old P/N 5:
1375365
1739356
Old P/N 6:
4.3 Superseded Thermoking Part Numbers Article No:
Description:
Part Number:
Old P/N 1:
Old P/N 2:
331984
MP3000A controller
45-2009
04-2009
336545
MP3000A Main relay board
45-2010
04-2010
345436
068-2094-00
66-9877
102-796
102-638
100277
Orifice for R-23 TXV 506431 Compressor, R-23 Super Freezer Motor Condenser 1200 RPM CRR40
104-689
104-666
K24-22021
100218
Motor Evaporator CRR40
104-691
104-670 (SF)
104-665
104-638
322471
Motor Condenser 1250 RPM Magnum/MPD/SF
104-759
K24-21158
104-677
104-697
K10-01217-00
340413
166170
Old P/N 3:
Old P/N 4:
Old P/N 5:
451909R
845-1909
845-1851
504-1370
452834R
845-2834
K24-21354
K24-21354
K15-70334-00
127736
Prestite tape for TXV Gasket metal/rubber (dis./such.) Gasket (discharge service valve) Probe kit, 508, CRR-40, Magnum
252603
HP Switch 350 Psi
41-3250
K25-51999-00
252786
Transformer 440/40V CRR40
41-3317
K25-52038-00
285935
41-3433
504-495
K24-52017-01
284051
Circuit breaker, 25 Amp. Contactor compressor, 24V , 25 Amp.
41-3605
41-2203
41-2446
K24-51820-16
K24-72475-25
310261
Compressor sensor
41-4300
41-3594
41-4156
504-246
41-2447
340415
HP-Switch , 470 PSIG , R-23 Relay MPC 2000 (SCHRACK)
41-4523
41-3668
41-1608
K25-72572-00
41-7587
K24-58162-02
504-514
44-6777
K25-51761-03
504-879
44-8340
504-636
K25-19666
356504 102482
252778 286028
203-428
509-1648
33-3175
33-2548
33-981
503-175
K28-04836
40-791
504-214
360-53039 K25-20869-00
360-50957
101117
Fuse, 2 Amp. Terminal, closed end, qty divisible by 10
340422
Fuse 7.5Amp.
44-9359
22-02336-08
350317
RMM Modem Repaired MPC2000 Main relay board repaired
451898R
845-1898
504-1230
845-1898
451906R
845-1906
K31-72387-00
K31-72008-00
350315
CENEQUVSLPUR Revision 1.5 Jan 2009
Old P/N 6: k3172520-00
360-50958
K31-52169-00
Page 26
Reefer Guidelines and Instructions
350312
MPC2000 controller repaired
451907R
845-1907
425344
Micro P.D. Controller
45-1949
845-1949
319671
502-240
360-70530-00
341950
Valve reed kit- Copeland Sensor for Deep freezer ONLY
504-1529
504-295
360-54235-00
100323
Contactor 24V , 15 Amp.
504-494
K24-51820-15
K24-50001
312482
Fuse, 20 Amp.
504-970
K25-70360-00
322837
KVQ-Actuator
504-980
K25-72045-00
340416
Filter Drier, R-23
506-421
K26-72553-00
340414
TXV, R-23 Super Freezer
506-431
K25-72552-00
252638
Evaporator fan
508-165
K26-72466-00
K26-52015-00
328842
Kit, TX valve
60-253
66-9001
66-9049
K25-52032-01
324447
Moisture Indicator , CRR-40
66-8811
66-9892
506-422
K26-72460-00
252611
Condenser fan CCR40 Compressor Copeland CRR40
78-1173
78-1079
8102-743
8102-646
365-70369-00
810-2743
316996
K24-50020
K25-52045-00
810-2646
66-6600
66-9900
8102-716
810-2716
4.4 Superseded Starcool Part Numbers Article No:
Description:
415022
Frequency Converter, Complete
415023
Compressor
415025
Economizer
814667C
814667B
CENEQUVSLPUR Revision 1.5 Jan 2009
Part Number:
Old P/N 1:
Old P/N 2:
818242C
814242B
814242C
818658B
814658B
Old P/N 3:
Old P/N 4:
Old P/N 5:
Old P/N 6:
Page 27
Reefer Guidelines and Instructions
5.0 GSMS Cross-Reference The procedures and guidelines in this document are also contained in the Global Ship Management System (GSMS). The table below gives a cross-reference between the paragraphs of this document and the document id’s in GSMS. All reefer procedures can be found in path: HOME | Procedures and Instructions | Ship Operations | Operation | Deck Operations | Cargo Operations | General Cargo Operations | Reefer Procedures Paragraph 1.0 Reefer Malfunction Reporting 1.0.1 Duty Phone 1.1 Acceptance & Repair of Shipper Owned Reefer Containers (SOC) 1.2 Repairs to reefer units of partner lines 1.3 Cannibalization of Empty Reefers 2.0 Ordering of Reefer Spare Parts 2.1 Allowance list 2.1.1 Compressor oil 2.2 Preferred reefer spare parts replenishment key ports 2.3 Reefer spare parts contacts 2.4 Consumable parts 2.5 Combining orders / minimum order value 2.6 Carrier Software and Configuration Cards 2.6.1 Software versions 2.6.2 Ordering software and configuration cards 2.7 Logman and reefer software 3.0 Returning of Defective Parts 3.1 Responsibility 3.2 Parts to be returned 3.3 Marking of parts to be returned and documentation required 3.3.1 Return Tag 3.3.2 Reefer Parts Return Form 3.4 Addresses where to send return parts 3.4.1 Carrier 3.4.2 Daikin 3.4.3 Thermoking 3.4.4 Starcool 3.5 Compressor Return Procedure 3.6 Electronics Return Procedure for Carrier and Thermoking 3.7 Reefer Unit Warranty 3.7.1 Container numbers – warranty units 4.0 Superseded Spare Parts Numbers 4.1 Superseded Carrier Part Numbers 4.2 Superseded Daikin Part Numbers 4.3 Superseded Thermoking Part Numbers 4.4 Superseded Starcool Part Numbers Annex I – Reefer Parts Return Form
Other • • •
GSMS Document ID new new 2920 2921 2893 2889 2895 / 9650 2895 2889 2889 2889 2889 new new new new 9663 2914 2915 2917 2917 2917 2916 2916 2916 2916 2916 2916 2916 2894 2894 9651 2912 2909 2911 new I-form 138
relevant procedures in GSMS are: 0223 – Reefer Electricians 6150 – Reefer Acceptance & Operational Manual 7153 – Quick Reference List
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 28
Reefer Guidelines and Instructions
Annex I – Reefer Parts Return Form
CENEQUVSLPUR Revision 1.5 Jan 2009
Page 29