pumps - motors - controls

pumps - motors - controls Engineered spring similar to modern automotive value designs Individual Piston Springs Offset piston assembly weight hold...
10 downloads 0 Views 2MB Size
pumps - motors - controls

Engineered spring similar to modern automotive value designs

Individual Piston Springs Offset piston assembly weight holds slippers on swashplate and reduces hydroplaning

A small amount of oil lubricates the shoe

Riveted design eliminates swaging of shoes and thinner neck than traditional designs

SAE 2 BOLT And 4 Bolt Mounting Flange

Multiple DRiveshaft Sizes

Spring holds shoe to swash plate eliminating hydroplaning, blowby, and side wear

Soft on hard combined with 90˚ machined grooves not tapered means the timing will never change

Thru Shaft Option

Dual Control Pistons with Adjustable NULL and Volume Stops – Standard Two piston design allows faster response time and offers greater control flexibility

www.hartmanncontrols.com

Bronze Rotor Excellent for low lubricity and contamination resistance

PH: (262) 367-4299

Patented Swashplate “In-Board” Trunnion Design Large Swashplate Bearings are located directly under high forces. Self aligning bearing design puts all components in compression for long life

FAX: (262) 367-5645

[email protected]

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

Bronze Slipper Shoe Unique spherical convex slipper design reduces unit loading and provides longer life



PVX

RATED PRESSURE

PEAK PRESSURE

MINIMUM PRESSURE

110 112 114 116 118 120 122

3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar) 3500 lb/in2 (241 bar)

4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar)

150 lb/in2 (10 bar) 150 lb/in2 (10 bar) 150 lb/in2 (10 bar) 150 lb/in2 (10 bar) 150 lb/in2 (10 bar) 150 lb/in2 (10 bar) 150 lb/in2 (10 bar)

PVX DISPLACEMENT

110 112 114 116 118 120 122

THEORETICAL FLOW @ 1800 rpm

INPUT TORQUE @ RATED PRESSURE



340 in-lb (38.4 N-m) 407 in-lb (46.0 N-m)   474 in-lb (53.6 N-m) SAE A 557 in-lb (62.9 N-m)   SAE AB 613 in-lb (69.3 N-m) 680 in-lb (76.8 N-m)   747 in-lb (84.4 N-m)

110 112 114 116 118 120 122

MAXIMUM SPEED @ ATM. PRESSURE

MINIMUM SPEED

3200 rpm 3200 rpm 3200 rpm 3200 rpm 3200 rpm 3200 rpm 3200 rpm

600 rpm 600 rpm 600 rpm 600 rpm 600 rpm 600 rpm 600 rpm

0.61 in3/rev (10 cm3/rev)   4.7 gal/min (17.8 l/min) 0.73 in3/rev (12 cm3/rev)   5.7 gal/min (21.6 l/min) 0.85 in3/rev (14 cm3/rev)   6.6 gal/min (25.0 l/min) 1.00 in3/rev (16 cm3/rev)   7.8 gal/min (29.5 l/min) 1.10 in3/rev (18 cm3/rev)   8.6 gal/min (32.5 l/min) 1.22 in3/rev (20 cm3/rev)   9.5 gal/min (36.0 l/min) 1.34 in3/rev (22 cm3/rev) 10.4 gal/min (39.4 l/min)

PVX

SHAFT SIZE

FRAME 0 V O LUMETR I C EFFI CI ENCY (%)



100

100

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

0 0

1000

2000

3000

P R E S S U R E

0 4000

( p s i )

RECOMMENDED TORQUE LIMIT

494 in-lb (  56.0 N-m) 971 in-lb (110.0 N-m)

• Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rear-mounted units. • SHIPPING WEIGHTS: Side Port = 37 lbs.

Rear Port = 35 lbs.

selector system

PVX

DISPLACEMENT 110 112 114 116 118 120 122

REAR FLANGE X

DRIVESHAFT AS – SAE A SPLINE AK – SAE A KEYED AB – SAE AB SPLINE BA – SAE AB KEYED

/

-

SUCTION GT – SAE # 20 (SIDE ONLY) AT – SAE # 16

ROTATION / PORTS 18 CW / REAR PORT 19 CCW / REAR PORT 20 CW / SIDE PORT 21 CCW / SIDE PORT

DISCHARGE AT – SAE # 16 LT – SAE # 12

* SPECIFY VOLT. / CONNECT. AND ENERGIZE OPTION + CONSULT FACTORY

www.hartmanncontrols.com

STACK CONTROLS FL – FIXED FLOW-LOAD COMPENSATOR AL – ADJ. FLOW-LOAD COMPENSATOR SS – SOFT START, ON / OFF CONTROL *

TOP CONTROLS PC – PRESSURE COMPENSATOR RC – REMOTE PRESSURE COMPENSATOR LP – LOW-PRESSURE COMPENSATOR PL – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) PH – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) LF – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) LH – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) FE – CONSULT FACTORY

REAR COUPLING XX

3

SPECIAL FEATURES V – SPECIAL +

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

OUTPUT FLOW/HORSEPOWER (NOT TO SCALE)

FRAME 0

FRAME 0

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

4



116



232



348



360

PEAK PRESSURE

5000 lb/in2 (345 bar) 4500 lb/in2 (310 bar)

6000 lb/in2 (417 bar) 5500 lb/in2 (379 bar)

200 lb/in2 (14 bar) 200 lb/in2 (14 bar)

4500 lb/in2 (310 bar) 3500 lb/in2 (241 bar)

5500 lb/in2 (379 bar) 4000 lb/in2 (276 bar)

200 lb/in2 (14 bar) 500 lb/in2 (34 bar)

PVX DISPLACEMENT THEORETICAL FLOW @ 1800 rpm

116



232



348



360

PVX

MAXIMUM SPEED MINIMUM @ ATM. PRESSURE SPEED

1.0 in3/rev (16 cm3/rev)   7.8 gal/min (  29.5 l/min) 2.0 in3/rev (32 cm3/rev) 15.6 gal/min (  59.0 l/min) 3.0 in3/rev (48 cm3/rev) 3.7 in3/rev (60 cm3/rev)

116

  797 in-lb (  90.0 N-m)



232

1,434 in-lb (161.0 N-m)



348



360

3200 rpm

600 rpm

3200 rpm

600 rpm

22.0 gal/min (  83.0 l/min)

2800 rpm

600 rpm

28.5 gal/min (107.9 l/min)

2800 rpm

600 rpm

INPUT TORQUE @ RATED PRESSURE



FrAme 1

MINIMUM PRESSURE 100

100

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

v o luMEtr I C EFFI CI EnCY (%)

PVX RATED PRESSURE

0 0

1000

2000

3000

P r E s s u r E

4000

0 5000

( p s i )

outPut Flow/horsEPowEr (not to sCalE)

FRAME 1

SHAFT SIZE RECOMMENDED TORQUE LIMIT

SAE B

1,450 in-lb (163.0 N-m)

  SAE BB 2,022 in-lb (230.0 N-m) SAE C 2,039 in-lb (230.0 N-m)

2,200 in-lb (248.0 N-m) 3,700 in-lb (417.0 N-m)

• Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rear-mounted units. • SHIPPING WEIGHTS: Side Port = 68 lbs.

Rear Port = 62 lbs.

selector system

PVX

-

-

DISPLACEMENT 116 232 348 DRIVESHAFT 360 BS – SAE B SPLINE BK – SAE B KEYED BB – SAE BB SPLINE KB – SAE BB KEYED CS – SAE C SPLINE * CK – SAE C KEYED *

REAR FLANGE A – SAE A PAD B – SAE B PAD +

/

-

ROTATION / PORTS 18 CW / REAR PORT 19 CCW / REAR PORT 20 CW / SIDE PORT 21 CCW / SIDE PORT

DISCHARGE FL – 11/4" CODE 61 FG – 11/4" CODE 62 GT – SAE # 20 AT – SAE # 16

REAR COUPLING AS – SAE A SPLINE AK – SAE A KEYED AB – SAE AB SPLINE BA – SAE BA KEYED BS – SAE B SPLINE + BK – SAE B KEYED +

5

SPECIAL FEATURES W – WATER BASED, AVAILABLE IN SAE B MOUNT ONLY V – SPECIAL +

SUCTION FL – 11/4" CODE 61 FL – 11/2" CODE 61 ** GT – SAE # 20

TOP CONTROLS PC – PRESSURE COMPENSATOR RC – REMOTE PRESSURE COMPENSATOR LP – LOW-PRESSURE COMPENSATOR PL – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) PH – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) LF – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) LH – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) TQ – TORQUE LIMITER **** FE – CONSULT FACTORY

* C MOUNT ONLY ** PVX 360 INLET 1 1/2" CODE 61 FLANGE *** SPECIFY VOLT. / CONNECT. AND ENERGIZE OPTION **** SPECIFY TERMINAL PRESSURE AND ORIFICE / HORSEPOWER + CONSULT FACTORY

www.hartmanncontrols.com

STACK CONTROLS FL – FIXED FLOW-LOAD COMPENSATOR AL – ADJ. FLOW-LOAD COMPENSATOR SS – SOFT START, ON / OFF CONTROL *** TQ – TORQUE LIMITER ****

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

FRAME 1

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

6

PVX RATED PRESSURE



464



580

4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar)

PEAK PRESSURE 5000 lb/in2 (345 bar) 5000 lb/in2 (345 bar)

500 lb/in2 (34 bar) 500 lb/in2 (34 bar)

PVX DISPLACEMENT THEORETICAL FLOW @ 1800 rpm

464



580

PVX

464



580

4.0 in3/rev (64 cm3/rev) 5.0 in3/rev (80 cm3/rev)

FrAme 2

MINIMUM PRESSURE

MAXIMUM SPEED MINIMUM @ ATM. PRESSURE SPEED

31.2 gal/min (118.0 l/min)

2800 rpm

600 rpm

39.0 gal/min (147.6 l/min)

2800 rpm

600 rpm

INPUT TORQUE @ RATED PRESSURE

SHAFT SIZE RECOMMENDED TORQUE LIMIT

v o luMEtr I C EFFI CI EnCY (%)



100

100

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

0 0

1000

2000

3000

P r E s s u r E

2,547 in-lb (286.8 N-m)

SAE C 3,184 in-lb (230.0 N-m)

4000

0 5000

( p s i )

5,328 in-lb (600.0 N-m)

• Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rear-mounted units. • SHIPPING WEIGHTS: Side Port = 118 lbs.

Rear Port = 110 lbs.

selector system

PVX

-

-

DISPLACEMENT 464 580 DRIVESHAFT CS – SAE C SPLINE CK – SAE C KEYED

REAR FLANGE A – SAE A PAD B – SAE B PAD C – SAE C PAD +

REAR COUPLING AS – SAE A SPLINE AK – SAE A KEYED AB – SAE AB SPLINE BA – SAE BA KEYED BS – SAE B SPLINE BK – SAE B KEYED BB – SAE BB SPLINE KB – SAE KB KEYED CS – SAE C SPLINE + CK – SAE C KEYED +

7

/

-

SUCTION FL – 2" CODE 61

ROTATION / PORTS 18 CW / REAR PORT 19 CCW / REAR PORT 20 CW / SIDE PORT 21 CCW / SIDE PORT

DISCHARGE FL – 11/4" CODE 61 FG – 11/4" CODE 62 GT – SAE # 20 AT – SAE # 16

STACK CONTROLS FL – FIXED FLOW-LOAD COMPENSATOR AL – ADJ. FLOW-LOAD COMPENSATOR SS – SOFT START, ON / OFF CONTROL * TQ – TORQUE LIMITER **

TOP CONTROLS PC – PRESSURE COMPENSATOR RC – REMOTE PRESSURE COMPENSATOR LP – LOW-PRESSURE COMPENSATOR PL – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) PH – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) LF – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) LH – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) TQ – TORQUE LIMITER **

* SPECIFY VOLT. / CONNECT. AND ENERGIZE OPTION ** SPECIFY TERMINAL PRESSURE AND ORIFICE / HORSEPOWER + CONSULT FACTORY

www.hartmanncontrols.com

SPECIAL FEATURES W – WATER BASED V – SPECIAL +

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

outPut Flow/horsEPowEr (not to sCalE)

FRAME 2

FRAME 2

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

8

PVX RATED PRESSURE

PEAK PRESSURE

MINIMUM PRESSURE

   696

3500 lb/in2 (241 bar)

4250 lb/in2 (293 bar)

500 lb/in2 (34 bar)

  7112

2

3500 lb/in (241 bar)

2

4250 lb/in (293 bar)

500 lb/in2 (34 bar)

  8128

3850 lb/in2 (265 bar)

4500 lb/in2 (310 bar)

500 lb/in2 (34 bar)

  9144

3850 lb/in2 (265 bar)

4500 lb/in2 (310 bar)

500 lb/in2 (34 bar)

10160

3850 lb/in2 (265 bar)

4500 lb/in2 (310 bar)

500 lb/in2 (34 bar)

PVX DISPLACEMENT THEORETICAL FLOW @ 1800 rpm

FrAme 3

MAXIMUM SPEED MINIMUM @ ATM. PRESSURE SPEED

   696   6.0 in3/rev (  96 cm3/rev)

46.8 gal/min (177.0 l/min)

2300 rpm

600 rpm

  7112   7.0 in3/rev (112 cm3/rev)

54.5 gal/min (206.0 l/min)

2200 rpm

600 rpm

  8128   8.0 in /rev (128 cm /rev)

62.3 gal/min (236.0 l/min)

2100 rpm

700 rpm

  9144   9.0 in /rev (144 cm /rev)

70.1 gal/min (265.0 l/min)

2100 rpm

700 rpm

10160

10.0 in3/rev (160 cm3/rev)

74.0 gal/min (280.0 l/min)

2000 rpm

700 rpm

PVX

INPUT TORQUE @ RATED PRESSURE

3

3

3

3

v o luMEtr I C EFFI CI EnCY (%)



100

100

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

0 0

1000

2000

3000

P r E s s u r E

0 4000

( p s i )

SHAFT SIZE RECOMMENDED TORQUE LIMIT

   696

3,343 in-lb (376.0 N-m)

  7112

3,900 in-lb (439.0 N-m)

  8128

4,903 in-lb (552.0 N-m)

SAE C

  9144

  SAE CC 5,516 in-lb (621.0 N-m)

10160

6,128 in-lb (690.0 N-m)

5,500 in-lb (  619.4 N-m) 9,500 in-lb (1070.0 N-m)

• Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rear-mounted units. • SHIPPING WEIGHTS: Side Port = 150 - 155 lbs.

Rear Port = 145 lbs.

selector system

PVX

DISPLACEMENT    696   7112   8128   9144 10160

-

DRIVESHAFT CS – SAE C SPLINE CK – SAE C KEYED CC – SAE CC SPLINE KC – SAE CC KEYED

REAR FLANGE A – SAE A PAD B – SAE B PAD C – SAE C PAD +

REAR COUPLING AS – SAE A SPLINE AK – SAE A KEYED AB – SAE AB SPLINE BA – SAE BA KEYED BS – SAE B SPLINE BK – SAE B KEYED BB – SAE BB SPLINE KB – SAE KB KEYED CS – SAE C SPLINE + CK – SAE C KEYED +

9

/

SPECIAL FEATURES W – WATER BASED V – SPECIAL +

SUCTION FL – 21/2" CODE 61

ROTATION / PORTS 18 CW / REAR PORT 19 CCW / REAR PORT 20 CW / SIDE PORT 21 CCW / SIDE PORT

DISCHARGE FL – 11/4" CODE 61 FG – 11/4" CODE 62 GT – SAE # 20

STACK CONTROLS FL – FIXED FLOW-LOAD COMPENSATOR AL – ADJ. FLOW-LOAD COMPENSATOR SS – SOFT START, ON / OFF CONTROL * TQ – TORQUE LIMITER **

TOP CONTROLS PC – PRESSURE COMPENSATOR RC – REMOTE PRESSURE COMPENSATOR LP – LIMITED-PRESSURE COMPENSATOR PL – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) PH – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) LF – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) LH – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) TQ – TORQUE LIMITER **

* SPECIFY VOLT. / CONNECT. AND ENERGIZE OPTION ** SPECIFY TERMINAL PRESSURE AND ORIFICE / HORSEPOWER + CONSULT FACTORY

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

outPut Flow/horsEPowEr (not to sCalE)

FRAME 3

FRAME 3

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

10

PVX RATED PRESSURE

PEAK PRESSURE

MINIMUM PRESSURE

4000 lb/in2 (276 bar) 4000 lb/in2 (276 bar)

4500 lb/in2 (310 bar) 4500 lb/in2 (310 bar)

500 lb/in2 (34 bar) 500 lb/in2 (34 bar)

11176

4000 lb/in2 (276 bar) 3250 lb/in2 (224 bar)

4500 lb/in2 (310 bar) 3750 lb/in2 (259 bar)

500 lb/in2 (34 bar) 500 lb/in2 (34 bar)

12190

3250 lb/in2 (224 bar)

3750 lb/in2 (259 bar)

500 lb/in2 (34 bar)

  8128   9144 10160

PVX DISPLACEMENT THEORETICAL FLOW @ 1800 rpm

FrAme 4

MAXIMUM SPEED MINIMUM @ ATM. PRESSURE SPEED

  8128   8.0 in3/rev (126 cm3/rev)   9144   9.0 in3/rev (144 cm3/rev)

62.3 gal/min (235.8 l/min)

2200 rpm

600 rpm

70.1 gal/min (265.3 l/min)

2200 rpm

600 rpm

77.9 gal/min (294.9 l/min)

2200 rpm

600 rpm

11176

10.0 in3/rev (160 cm3/rev) 11.0 in3/rev (176 cm3/rev)

85.7 gal/min (324.5 l/min)

2200 rpm

650 rpm

12190

11.7 in3/rev (190 cm3/rev)

91.1 gal/min (344.8 l/min)

2200 rpm

650 rpm

PVX

INPUT TORQUE @ RATED PRESSURE

10160

100

100

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

v o luMEtr I C EFFI CI EnCY (%)



0 0

1000

2000

P r E s s u r E

3000

0 4000

( p s i )

SHAFT SIZE RECOMMENDED TORQUE LIMIT

  8128

5094 in-lb (575.5 N-m)

  9144

5731 in-lb (647.5 N-m)

10160

6367 in-lb (719.4 N-m)

11176

5691 in-lb (643.0 N-m)

12190

6053 in-lb (683.9 N-m)

SAE D

14,500 in-lb (1,638.0 N-m)

• Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rear-mounted units. • SHIPPING WEIGHTS: Side Port = 188 lbs.

selector system

PVX

DISPLACEMENT   8128   9144 10160 11176 12190

-

DRIVESHAFT DS – SAE D SPLINE DK – SAE D KEYED

REAR FLANGE A – SAE A PAD B – SAE B PAD C – SAE C PAD

/

-

ROTATION / PORTS 20 CW / SIDE PORT 21 CCW / SIDE PORT

DISCHARGE FL – 11/2" CODE 61 FG – 11/2" CODE 62

REAR COUPLING AS – SAE A SPLINE AK – SAE A KEYED AB – SAE AB SPLINE BA – SAE BA KEYED BS – SAE B SPLINE BK – SAE B KEYED BB – SAE BB SPLINE KB – SAE KB KEYED CS – SAE C SPLINE CK – SAE C KEYED

11

STACK CONTROLS FL – FIXED FLOW-LOAD COMPENSATOR AL – ADJ. FLOW-LOAD COMPENSATOR SS – SOFT START, ON / OFF CONTROL * TQ – TORQUE LIMITER **

TOP CONTROLS PC – PRESSURE COMPENSATOR RC – REMOTE PRESSURE COMPENSATOR LP – LOW-PRESSURE COMPENSATOR PL – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) PH – ADJ. FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) LF – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (LO-RATE) LH – FIXED FLOW-LOAD/PRESSURE COMPENSATOR (HI-RATE) TQ – TORQUE LIMITER **

* SPECIFY VOLT. / CONNECT. AND ENERGIZE OPTION ** SPECIFY TERMINAL PRESSURE AND ORIFICE / HORSEPOWER + CONSULT FACTORY

www.hartmanncontrols.com

SPECIAL FEATURES V – SPECIAL +

SUCTION FL – 3" CODE 61

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

outPut Flow/horsEPowEr (not to sCalE)

FRAME 4

FRAME 4

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

12

Controls Options PC

Pressure Compensator

RC

Standard Remote Compensator

SC

Pressure Compensator Positioned 90 Degrees From Standard Mounting

HC

Hand Wheel Adjustable Pressure Compensator

LP

Low Rate Pressure Compensator Positioned 90 Degrees From Standard Mounting

FL

Fixed Delta, Flow-Load Sensor (Low Rate)

FH

Fixed Delta, Flow-Load Sensor (High Rate)

AL

Adjustable Delta, Flow-Load Sensor (Low Rate)

AH

Adjustable Delta, Flow-Load Sensor (High Rate)

FB

Fixed Delta, Flow-Load Sensor w/Bleed Down (Low Rate)

HB

Fixed Delta, Flow-Load Sensor w/Bleed Down (High Rate)

AB

Adjustable Delta, Flow-Load Sensor w/Bleed Down (Low Rate)

BH

Adjustable Delta, Flow-Load Sensor w/Bleed Down (High Rate)

TQ

Torque Limiter

CP

Constant Pressure Manifold

DM

Dump Manifold

2P

Two Pressure Compensators Selection

SS

Soft Start

PL

Adjustable Integrated Flow-Load Sensor/Pressure Compensator (Low Rate)

PH

Adustable Integrated Flow-Load Sensor/Pressure Compensator (High Rate)

LF

Fixed Integrated Flow-Load Sensor/Pressure Compensator (Low Rate)

LH

Fixed Integrated Flow-Load Sensor/Pressure Compensator (High Rate)

EP

Electronic Pressure Control

EF

Electronic Flow Control

EC

PWM Control Board w/ Connections

Fluids

13

Hartmann PVX Piston Pumps have been used in the following types of Hydraulic Fluid Preperations

1) sub-sea preparations

5) high water content fluids (HWCF)

2) fire-resistant preparations

6) phosphate esters

3) water glycols

7) polyol esters

4) invert-emulsions

8) synthetic blends

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

PV Atmospheric Inlet Piston Pumps and Motors Open Loop Variable Displacement Piston Pumps in 52 and 70 CC (3.2 to 4.2 Cu In) displacement. Available in multiple porting, shaft, and control configurations

PVC Atmospheric Inlet Piston Pumps and Motors Open Loop Variable Displacement Piston Pumps in 56 and 70 CC (3.4 to 4.3 Cu In) displacement. Available in SAE B and C keyed and splined shafts and multiple porting and control configurations

Hartmann Rol-Vane Motors Fast responding, infinitely variable speed Hydraulic Servo-Motor. The RolVane motor offers smooth operation, high torque, and instant reversing

www.hartmanncontrols.com

PH: (262) 367-4299

FAX: (262) 367-5645

[email protected]

14

The Hartmann Commitment • Fulfill and expedite orders in as little as 12 hours • Deliver regular orders in 3-4 weeks including pump combinations never before produced • Maintain a repair/rebuild facility staffed by experienced hydraulic technicians for immediate response to downtime • 100% of production and repair/rebuild is performance tested • All critical components are produced in-house • Design and produce pumps that: - Exceed expectations - Incorporate the best materials - Incorporate the latest technology - Reduce energy consumption

Please Contact Your Local Distributor for Further Information

HARTMANN CONTROLS, INC. 604 Progress Drive Hartland, WI USA 53029

PHONE: (262) 367-4299 FAX: (262) 367-5645 E-MAIL: [email protected] www.hartmanncontrols.com

MADE IN U.S.A.

Suggest Documents