Extremely easy operation Big graphic screen 20 characters x 8 lines big size graphic display is adopted. The graphic display remarkably increases the ease of operation. The soft key designations are displayed with large characters allowing simple, easy and comfortable instrument operation every time.

PCS-315 / PCS-325 / PCS-335

Special Functions A total of 9 Special functions, Distance stakeout, RDM, Coordinates, Offset shots, Coord. stakeout, REM, Resection, Data storage, Memory management are incorporated in the instrument.

Internal Memory A total of 5,000 points with both Survey data and Coordinate data combined can be stored. End users can freely allocate the memory capacity according to their needs.

Recharger with a refreshing function The battery recharger provided as an accessory includes a refreshing function which lets the battery recover from the "memory effect"(*) that results in the usage time of the battery being gradually reduced as the battery is used.

Remote Control Alpha Keyboard (Optional accessory) Entering descriptions faster and easier is now available with the MU72 infrared remote control. This 32 keys, no cable, small and lightweight controller for your PCS-325 is the ultimate in convenience and speed. (MU72 is not used with PCS-315/335.)

Automatic atmospheric sensor The built-in automatic atmospheric sensor measures the temperature and pressure in real time, and initiates ppm correction. Thus, the user no longer needs to bother with inputting these data, saving both time and trouble. (Accuracy: Approx.10 ppm)

Compact battery The palm-sized, compact battery weighs a mere 155g. Two battery packs are provided as a standard feature, and each battery lasts approximately 2.5 hours when using continuous measurement. Measurement can thus be carried out for 5 hours without interruption. (2 battery packs : for PCS-325 only)

Water protection structure

Code Name 007

MC04 Charger

* The"memory effect" Ni-Cd batteries can be used again and again by recharging them, but if the battery is repeatedly recharged before the battery is fully discharged, a phenomenon called the "memory effect" causes the time that the battery can be used after recharging to become shorter and shorter. When a Ni-Cd battery is refreshed, its voltage is restored and the usage time returns to the original value. Refreshing the battery once every five times it is recharged effectively maintain the full usage time.

This enables all of the functions, special measurements, as well as changes to initial settings such as prism constants and the minimum angle display, to be loaded simply using the code number "007".

The tilt sensor The PCS-325 incorporates 2 axis tilt sensor, and the PCS-315/335 1 axis sensor.

Graphic Help Pushing the [HELP] key while executing the Special functions displays the general drawing of the Special functions with an explanation as a Help message.

The water protection class is JIS class 4. The rain cannot come into the inside of the instrument in unexpected rainfall , and so you can operate it free from care. The instrument can be operated easily and lightly as usual under the severe worksite.

Special Functions of PCS-300 series

Data Storage With Data storage measurement, the data of JOB NAME, STATION POINT and SURVEY results can be stored in the internal memory of the instrument.

Station P. (X,Y,Z)

RDM With RDM measurement, the horizontal distance, slope distance, difference in height and percentage of slope between the reference point and the observation point are measured. The distance between one observation point and another one is measured as well.

P-P P-P

%slope difference in height

Refe

renc

e P.

Refe

renc

e P.

Coordinates Any desired target Coordinates can be determined and stored by setting the station point as an original point and inputting the backsight Coordinate in Coordinate measurement. The Coordinates values from tne original Coordinates point can be determined by the station Coordinates input even if the station point is not set as an original point. Coordinates values input can be omitted by designating the station point No. whenever the station Coordinates are stored in the internal memory.

Backsight P. (X,Y, Z) Z

Y

Station P. (X,Y,Z)

X

Offset shots Offset shots is used when the Prism cannot be positioned because of an obstacle in the way. With this type of measurement, the Target Coordinates are measured indirectly. Coordinates values input can be omitted by designating the Station point number whenever the Station coordinates are stored in the internal memory.

Backsight P.(X,Y, Z)

Offset P.

Target(X,Y,Z)

Station P.(X,Y,Z)

Distance Stakeout With Distance Stakeout measurement, the Deviation between the input design values (specified distance) and the distance to the prism is displayed, making it easier to stake a point.

D

g esi

nv

alu

e

Deviation

Me

asu

red

ue val

REM With REM measurement, a Prism (reference point) is set directly below the place to be measured, and by measuring the Prism, the height to the Target object can be measured. This makes it easy to determine the heights of electric power lines, bridge suspension cables, and other large items used in construction.

Height   

Coordinates stakeout With Coordinates stakeout measurement, the Staking point coordinates can be staked out in 3 dimensions based on the known Station point coordinates and Backsight point coordinates or Backsight point azimuth . The horizontal angle, horizontal distance and vertical distance to the Staking point are automatically calculated as design values, and the differences between the measured values and design values are displayed as deviations. When the coordinate values of the station point, backsight point and Staking point are recorded in the internal memory, designation of each measured point number makes it possible to omit the coordinates value input each time. ? ? ? ?W.?eW.e? ?7H?e7He? J@f@?e? 7@L??J@Le? 3@,??'@,e? V+Y??V+Ye? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

? ? ? ?W-X?W-Xhg? ?*@)?*@)hg? ?N@H?N@Hhg? @?e@?hg? ?J5??J5?hg? ?.Y??.Y?hg? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

? ? ? ?W.?eW.e? ?7H?e7He? J@f@?e? 7@L??J@Le? 3@,??'@,e? V+Y??V+Ye? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

? ? ? ?W-X?W-Xhg? ?*@)?*@)hg? ?N@H?N@Hhg? @?e@?hg? ?J5??J5?hg? ?.Y??.Y?hg? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

? ? ? ?W.?eW.e? ?7H?e7He? J@f@?e? 7@L??J@Le? 3@,??'@,e? V+Y??V+Ye? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

? ? ? ?W-X?W-Xhg? ?*@)?*@)hg? ?N@H?N@Hhg? @?e@?hg? ?J5??J5?hg? ?.Y??.Y?hg? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

Backsight P.   (X,Y,Z)

Staking P.(X,Y,Z)

Station P.(X,Y,Z)

Resection With Resection measurement, 2 or 3 known points are measured in order to determine the Coordinate of the station point. Each Coordinate input can be omitted by designating each point number when the Coordinate values of point A, B and C are stored in an internal memory.

Point A

Point B

New P.(X, Y, Z)

Power Supply System and Accessories of PCS-300 series

Power Supply System

Diagonal eyepiece SB11

SC6 Bar compass

MU73 Solar filter MU68 Vehicle cable

MC04 MB07 External battery

MC04 Battery charger (standard accessory)

MU74 External battery adapter

TS cable MB02 On-board battery (standard accessory)

Data collector

Host cable PCS-300 series

Host cable

Various Computers

MU72 Remote control (PCS-325 only)

Aluminium tripod TS-3 TC-3

Wooden tripod TS-2 TC-2

Diagonal Eyepiecs(SB 11)

Bar compass(SC 6)

Solar filter(MU 73)

An diagonal eyepiece can be used for the observation of Zenith or for the mesurement in a confined space.

A bar compass can be mounted onto the hand grip to obtain the magnetic north.

For solar observation,a solar filter is required to be mounted on the objective lens.

Prism Unit and Pole Adapter of PCS-300 series

Prism Unit 1P coaxial target MT15 3P coaxial target MT16 3P holder MP27

Prisms

MP12 MP14

1P tilt holder MP26

Prisms

MP12 MP14

Tribrach adapter (W/O O. P.) MS36

Tribrach adapter (W/O.P.) MS35

Prisms adapter shift type MS38

MPU-6A/6B

Tribrach PW12 (W/O O.P.)

MPU-8A/8B

MPU-5A/5B

Tribrach adapter PW22 (W/O.P.)

MPU-7A/7B

Pole Adapter

Prisms

MP12 MP14

Prisms

MPU-5A Prism const. −30 MPU-05A Prism const. 0

) )

1P tilt holder MP26

Pole adapter MT45

Pole adapter MT45

Range Pole (A pole of 20mmφ ∼30mmφ can be used with MT45)

Range Pole (A pole of 20mmφ ∼30mmφ can be used with MT45)

3P unit shift type A

1P tilt unit A

( (

MP12 MP14

(MPU-8A)

Standard configuration Instrument(W/objective cap) Battery pack(PCS-325,2 pcs) A set of plumb bob A set of tool Rain cover Carrying case Battery charger

SPECIFICATIONS PCS-315

PCS-325

PCS-335

Telescope

PCS-325

PCS-335

Display section

Image Magnification Effective aperture Resolving power Field of view Minimum focus

Erect 30 x 40mm (EDM40mm) 3" 2.6%(1° 30') 0.85m

Distance measurement *800m **1000m 3P *1200m **1500m *Normal conditions : 20km visibility with slight haze **Good conditions : 40km visibility, overcast, no heat no haze and moderate wind

Accuracy

± 3mm + 2ppm x D) mm ( *± mm (3mm + 10ppm x D) D: Distance *Automatic atmospheric correction

Minimum count

Normal : 1mm or 0.1mm Fast : 10mm or 1mm

Measuring time

Normal : 2sec.(1mm), 3sec.(0.1mm) Fast : 0.4sec.(10mm), 0.8sec.(1mm) Automatically repeated or shot (Shot: 1,3,5AV or input(1 ∼ 99)

Measuring system Maximum slope distance display

3000.000m AUTO/ATM INPUT/ppm INPUT/NIL Temperature input, Pressure input, ppm INPUT(-199 ∼ +199 ppm)

Atmospheric correction Prism constant

-30mm, 0mm, INPUT

Atmospheric and earth curvature correction

0.14, 0.2, NIL

Special functions Coord. stakeout Distance stakeout RDM Coordinates Offset shots

Dot

240 x 96

Dot character and segment

20 characters x 8 lines w/back light

Sensitivity of vials Plate vial Circular vial

40"/2mm

30"/2mm 8'/2mm

40"/2mm

Optical plummet 1P

Measurement range

PCS-315

REM Resection Data storage Memory management

Angle measurement Measuring method

Incremental rotary encoder

Detection method

Horizontal angle .....Double Vertical angle .........Single 1"(2cc)/5"(10cc) 5" standard deviation 0.2"(Continuous) 79mm

Minimum count Accuracy(DIN18723) Measuring time Diameter of circles

Image Magnification Focus range

Erect 3x 0.5m ∼ ∞

Vertical axis. Tribrach type Vertical axis Tribrach

Fixed

Single Detachable

Shift

Data Output Interface Baud rate Data bits Parity bits Stop bits

RS-232C 1200, 2400, 4800, 9600 8 bit, 7 bit Nil, Even, Odd 1, 2

Auto Power off Setting up time

Nil, 10min.20min.30min.

Ambient temperature Working range

-20° C ∼ +50° C/-4° F ∼ 122° F

Tripod thread PCS-325/315 PCS335

5/8" x 11(JIS/B) 35mm x 2(JIS/C)

Dimensions/Weight Instrument Carrying case

156 . x 341(H)x 158(L)mm/5.1kg (W) 270 . x 350(H)x 440(L)mm/3.8kg (W)

Battery pack MB02 Power source Output voltage Operation time Weight

NiCd(Rechargeable) DC6V Continuous Approx.2.5hrs. Approx. 155g

Charger MC04 Input voltage Output voltage Charging time Weight

AC100-240V 50/60Hz DC6V-7.2V(0.5A) Approx. 55min.(1100mAh) Approx. 800g

Internal Memory Surveying data + Coordinates data Total 5000 points *Designs and specifications are subject to change without notice.

H: R/L, Hold, Retention(in Power OFF) V: Zenith 0/ Horizontal 0, %, Compass

Measuring mode

CERTIFIED ISO 9001 & 14001 Asahi Precision Co., Ltd. 1-1-21, Shirako, Wako-shi, Saitama-ken, 351-0101, Japan Tel:048(461)5377

Pentax U.K.Limited Pentax House, Heron Drive, Langley, Slough, SL 38 PN, United Kingdom Tel:(01753)792 792

Pentax Corporation 35 Inverness Drive East, Englewood, Colorado 80112 U.S.A. Tel:(303)799-8000

Pentax France S.A. 12/14 rue Jean Poulmarch BP 204 95106 Argenteuil, France Tel:(1)30 25 75 75

Pentax Canada Inc. 3131 Universal Drive, Mississauga, Ontario L4X 2E5 Canada Tel:(905)625-4930

Pentax Benelux Spinveld 25, 4815 Hr Breda, Netherlands Tel:(076)531 3031

Pentax Europe n.v. Weiveldlaan 3-5, 1930 Zaventem, Belgium Tel:(02)725 05 70

Pentax Scandinavia Bolandsgatan 15 C 75127 Uppsala Sweden Tel:(46)-18-71-1300

Pentax GmbH. Julius-Vosseler-Str. 104 22527 Hamburg 54, Germany Tel:(040)561 92-170/109

Pentax (Schweiz) AG Industriestrasse 2 CH-8305 Dietlikon Switzerland Tel:(41)-1-833-38-60

http://www. pentax. co. jp/apc/ Printed in Japan 1999.09-03

Suggest Documents