Page 11-4 SWITCH DISCONNECTORS 16A TO 125A (AC21A) • Switch disconnectors with direct operating handle and door coupling version • Switch disconnector...
Author: Beatrice Wilson
3 downloads 2 Views 8MB Size
Page 11-4 SWITCH DISCONNECTORS 16A TO 125A (AC21A) • Switch disconnectors with direct operating handle and door coupling version • Switch disconnectors with front door mount • Switch disconnectors in non-metallic enclosure

• Changeover switches in non-metallic enclosure.

Page 11-16 SWITCH DISCONNECTORS 50A TO 1600A (AC21A) • Three and four-pole switch disconnectors • Three and four-pole switch disconnectors with NFC, NH and BS type fuse holders • Three and four-pole changeover switches; add-on motorised control unit available.

Page 11-24 FOR PHOTOVOLTAIC APPLICATIONS UP TO 850A 1000VDC (DC21B) • Three and four-pole switch disconnectors • Direct operating and door coupling versions • Serial connection of 2, 3, 4, 6 and 8 poles.

11

SWITCH DISCONNECTORS

16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty Changeover switches in polycarbonate enclosure.

GA series 16A to 125A Three-pole switch disconnectors ............................................................................................................................................ Fourth pole add on..................................................................................................................................................................... Add-on blocks and accessories ............................................................................................................................................... Empty non-metallic enclosures .............................................................................................................................................. Enclosed switch disconnectors .............................................................................................................................................. Enclosed changeover switches ...............................................................................................................................................

SEC. - PAGE 11 11 11 11 11 11

-

4 5 7 11 12 14

11 11 11 11 11 11 11 11

-

16 16 17 17 18 18 19 21

GE series 50A to 1600A Three-pole switch disconnectors ............................................................................................................................................ Three-pole switch disconnectors with fuse holder ................................................................................................................ Four-pole switch disconnectors ............................................................................................................................................. Four-pole switch disconnectors with fuse holder .................................................................................................................. Three-pole changeover switches ............................................................................................................................................ Four-pole changeover switches ............................................................................................................................................... Add-on blocks and accessories .............................................................................................................................................. Combinations ...........................................................................................................................................................................

AND

C IRCUIT P ROTECTION

Dimensions ................................................................................................................. 11 - 26 Wiring diagrams ........................................................................................................... 11 - 50 Technical characteristics ................................................................................................. 11 - 53

I SOLATION

For photovoltaic applications ....................................................................................................................................... 11 - 24

Switch disconnectors Overview GA series 16A to 125A

DIRECT OPERATING HANDLE AND DOOR COUPLING VERSION 36mm / 1.42” width IEC AC21A Three pole

DOOR MOUNT VERSION

70mm / 2.75” width

36mm / 1.42” width

70mm / 2.75” width

16A

25A

32A

40A

63A

63A

80A

100A

125A

16A

25A

32A

40A

63A

80A

100A



















































4th pole - simultaneous closing





4th pole - early-make closing





Three-pole for photovoltaic applications











125A







Fuse holder Mechanical 6-8 pole coupling system





Mechanical interlock for line switching





11 ENCLOSED VERSION - IEC/EN TYPE IP65 WITH RED/ YELLOW OR BLACK HANDLE IEC AC21A

16A

25A

32A

40A

63A

63A

80A

ENCLOSED VERSION - UL/CSA TYPE 4/4X WITH RED/ YELLOW OR BLACK HANDLE

100A 125A

UL/CSA general use 600VAC

16A

25A

32A

40A

63A

63A

80A

100A

125A

16A

25A

32A

40A

60A

60A

100A 100A

100A

Enclosure width 100mm / 3.94”

Enclosure width 220mm 8.66”

175mm / 6.89”

100mm / 3.94”

175mm / 6.89”

220mm / 8.66”

SWITCH DISCONNECTORS Three pole



Four pole























































Enclosure width CHANGEOVER SWITCHES

175mm / 6.89”

220mm / 8.66”

Three pole











Four pole











Switch disconnectors

GE series 50A to 1600A

Changeover switches

DIRECT OPERATING AND DOOR COUPLING VERSION IEC AC21A

50A

125A

160A

200A

250A

315A

400A

500A

630A

800A

1000A

1250A

1600A











































SWITCH DISCONNECTORS 50A TO 1600A Three and four pole Three and four pole with NFC fuse holder





Three and four pole with NH fuse holder



Three and four pole with BS fuse holder



Four-pole for photovoltaic applications



 













CHANGEOVER SWITCHES 160A TO 1600A Three and four pole Motorised control unit

11-2







 









 



Switch disconnectors Overview

VERSATILITY! VERSION FOR PHOTOVOLTAIC APPLICATIONS The GA...D type switch disconnectors are suitable for both small domestic installations as well as those with a large number of solar cells. Use up to 1000V in DC21B category.

COMPACT SIZE The three-pole 16A to 63A switch disconnectors, are made up of a single unit body, merely 36mm/1.4” wide, while the 63A to 125A ratings, of another body size of only 70mm/2.8” wide.

CERTIFICATIONS All GA series switch disconnectors are certified by EAC, cCSAus and UL Listed for Canada and USA. The 16A to 63A types are certified according to UL508/CSA 22.2 n° 14 while the 63A to 125A types to UL98/CSA 22.2 n° 4 standards.

ACCESSORY FLEXIBILITY Mounting and removal of the fourth pole and add-on blocks are simple and quick operations with no need of tools.

11 SIDE MOUNT ADD-ON FOURTH POLE Simultaneous or early-make contact operation of the fourth pole with respect to the switch disconnector poles.

6 AND 8 POLE VERSION A mechanical coupling system is available for the 16A to 125A switch disconnectors with direct operating handle to provide 6/8 pole disconnectors along with a mechanical interlock mechanism for the line changeover function (I - 0 - II). Enclosed changeover switches are available in a variety of ratings and cCSAus certified.

IP65 PADLOCKABLE HANDLES Wide range of selector or pistol grip handles, with screw or ring fixing. All handles are equipped with builtin padlockable mechanism. The selector handle GAX63... snaps onto the door-mount switch disconnectors in16A to 40A ratings, with no need of tools.

SWITCH STATUS INDICATION The switch open or closed state is clearly and unequivocally seen at a distance thanks to the simple and modern design of the handle.

DIN RAIL FIXING Switch disconnector mounting on and removal from the 35mm (IEC/EN 60715) DIN rail are done by simply pressing it downwards with no need of tools.

PAD INSERT FOR NO SLIDING ADD-ON AUXILIARY CONTACTS One only add-on block suitable for all the 8 ratings of switch disconnectors, having simultaneuous operation with the switch poles. There are versions with an early-break NO contact. MAXIMUM COMBINATIONS Mounting up to 4 auxiliary contacts or 1 fourth pole and 3 auxiliary contacts (2 blocks always on the right and 2 on the left side) of each switch disconnector. The earth and neutral terminals and fuse holder also can be added.

9mm/0.35”

HANDLE ADAPABILITY The extensive number of fixing holes in the front handle plate can replace switch disconnectors, normally found out in the field, without having to drill others.

FUSE HOLDERS

A three-pole fuse holder can be added to 16A to 32A switch disconnectors, with direct operating handle, to provide a single compact unit. Access to the fuse can be made only when the disconnector is in OFF position. UL Listed type up to 25A class CC fuses. REDUCED HANDLE THICKNESS GAX61 and GAX 61 B handles are only 23mm/0.9” thick.

DEFEATABLE UL508A HANDLE VERSION In compliance with UL508A standards, which require internal panel inspection by authorised personnel with power applied, selector and lever handles are available with defeatable feature of the door coupling when the switch disconnector is closed, i.e. in ON position.

A rubber pad insert prevents the sliding of switch disconnectors on the DIN rail even when out of tolerance or mounted vertically.

TERMINAL ADAPTABILITY Terminals are suitable to accept any type of cable: flexible, rigid, AWG wire. The terminals can withstand high tightening torques.

HIGH IEC CAPABILITY IN AC23 The rated currents Ie in AC23 at 690VAC are the highest of the category.

MODULARITY The switch disconnectors can be mounted in modular panels.

23mm/0.9”

11-3

Switch disconnectors GA series 16A to 125A

Order code

IEC conventional free air thermal current Ith AC21A (690V)

IEC rated operational current Ie

[A]

[A]

Qty Wt per pkg

AC22A (690V) AC23A (415V) n°

[kg]

Direct operating version, complete with black handle. For door-coupling version, separately purchase the handle and shaft extension; refer to pages 11-9 and 11-10. 16

1

0.146

25

25

1

0.146

GA032 A

32

32

1

0.146

GA040 A

40

40

1

0.146

GA063 SA

63

45

1

0.148

GA063 A

63

63

1

0.388

GA080 A

80

80

1

0.388

GA100 A

100

100

1

0.388

GA125 A

125

125

1

0.388

Operational characteristics – IEC rated insulation voltage Ui: 1000V – IEC rated impulse withstand Uimp: 8kV – Electrical life in IEC AC21A: • 100,000 cycles for GA016-GA040 • 15,000 cycles for GA063 SA • 30,000 cycles for GA063-GA125 – Mechanical life: • 100,000 cycles for GA016-GA040-GA063 SA • 30,000 cycles for GA063-GA125. Certifications and compliance Certifications obtained:

Door-mount version, complete with shaft; separately purchase the handle, refer to pages 11-9.

11

GA016 C... GA040 C

GA063 C... GA125 C

GA016 C

16

16

1

0.170

GA025 C

25

25

1

0.170

GA032 C

32

32

1

0.170

GA040 C

40

40

1

0.170

GA063 C

63

63

1

0.404

GA080 C

80

80

1

0.404

GA100 C

100

100

1

0.404

GA125 C

125

125

1

0.404

Strokes of GA switch poles Travel 0→1 0°

30°

60° 60°

GA016 A...GA040 A - GA063SA

90°

60°

GA016 C...GA040 C

55°

GA063 C...GA125 C OFF

GA016 A...GA040 A







––

GA063 SA



––



––

GA016 C...GA040 C







––

GA063 A...GA125 A



––

––



GA063 C...GA125 C



––

––



Type

 Certification obtained.

55°

GA063 A...GA125 A

cULus per UL98 / CSA C22.2 n°4 UL Listed (File E328470)

16

GA025 A

cULus per UL508 / CSA C22.2 n°14 UL Listed (File E93602)

GA063 A... GA125 A

GA016 A

KEMA

GA016 A... GA040 A GA063 SA

General characteristics – IEC 16A to 125A ratings – Available versions: • Direct operating • Door mount • Door coupling version. Use switch disconnector with direct operating handle and separately purchase the handle and shaft extension for this version. See pages 11-9 and 11-10 – Compact and modular size – Screw or 35mm DIN (IEC/EN 60715) rail fixing – Padlockable in 0 position with no extra accessory.

EAC

Three-pole switch disconnectors

ON

Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, UL98, CSA C22.2.

UL/CSA ratings Type

1 phase [HP]

3 phase [HP]

General use at 600VAC

Shortcircuit rating at 600VAC

Fuse class max rating at 600V

120V

240V

200208V

240V

480V

600V

[A]

[kA]

Type - [A] RK5 - 20A

GA016...

1

2

5

5

10

10

16

5

GA025...

11/2

3

71/2

71/2

15

20

25

5

RK5 - 30A

GA032...

2

5

10

10

20

20

32

5

RK5 - 35A

GA040...

2

5

10

15

20

25

40

5

RK5 - 45A

71/2

10

15

30

30

60

5

RK5 - 45A

GA063 SA 2

NOTE: Above ratings are valid for GA…A, GA…C and GA…D (on page 11-24) types, according to UL508 and CSA 22.2 n°14. UL Listed for USA and Canada (cULus - File E93602), as Manual Motor Controllers while UL designation is “GENERAL PURPOSE SWITCH. INTERRUPTEUR USAGE GENERAL” and “SUITABLE AS MOTOR DISCONNECT”.

Type

1 phase [HP]

120V

3 phase [HP]

240V

200240V 208V

480V

600V

General use at 600VAC

Shortcircuit rating at 600VAC

Max fuse rating at 600V

[A]

[kA]

[A]

GA063... 3

71/2

20

20

40

40

60

10

100

GA080...

3

10

25

25

40

40

100

10

100

GA100...

5

10

30

30

50

50

100

10

100

GA125...

71/2

10

30

30

60

60

100

10

100

NOTE: Above ratings are valid for GA…A, GA…C and GA…D (on page 11-24) types, according to UL98 and CSA C22.2 N°4. UL Listed for USA and Canada (cULus - File E328470), as Open Type Switches – Open type unfused switch while UL designation is “GENERAL PURPOSE SWITCH. INTERRUPTEUR USAGE GENERAL”.  Lower ratings in this same UL/CSA category are available on specific request for volume orders. For information, consult Customer Service; see contact details on inside front cover.  Voltage value not considered in UL98 / CSA 22.2 n°4 standards so not indicated in UL product marking.

11-4

Add-on blocks/Accessories pages 11-6 to 10

Dimensions pages 11-26 to 28

Wiring diagrams page 11-50

Technical characteristics page 11-53

Switch disconnectors GA series 16A to 125A Fourth pole add on

Order code

IEC conventional free air thermal current Ith AC21A (690V)

IEC rated operational current Ie

[A]

[A]

Qty Wt per pkg

AC22A (690V) AC23A (415V) n°

[kg]

Simultaneous closing operation as switch poles. For GA...A version.

GAX42...A GAX41...A GAX42 063SA GAX41 063SA

GAX42 040A 40

40

1

0.045

GAX42 063SA 63

45

1

0.045

GAX42 063A

63

63

1

0.126

GAX42 080A

80

80

1

0.126

GAX42 100A

100

100

1

0.126

GAX42 125A

125

125

1

0.126

GAX42 040C 40

40

1

0.045

GAX42 063C

63

63

1

0.128

GAX42 080C

80

80

1

0.128

GAX42 100C

100

100

1

0.128

GAX42 125C

125

125

1

0.128

For GA...C version.

General characteristics – IEC 16A to 125A ratings – Available version for: • Direct operating • Door mount • Simultaneous closing with switch poles • Early-make closing respect with switch poles – Compact and modular size. Operational characteristics – IEC rated insulation voltage Ui: 1000V – IEC rated impulse withstand Uimp: 8kV – Electrical life in IEC AC21A: • 100,000 cycles for GAX42 040A/C and GAX41 040A/C • 15,000 cycles for GAX42 063SA and GAX41 063SA • 30,000 cycles for GAX42 063A/C and GAX41 125A/C – Mechanical life: • 100,000 cycles for GAX42 040A/C and GAX41 040A/C, GAX42 063SA and GAX41 063SA • 30,000 cycles for GAX42 063A/C - GAX42 125A/C and GAX41 125A/C. Certifications and compliance Certifications obtained:

GAX41 040A 40

40

1

0.046

GAX41 063SA 63

45

1

0.046

GAX41 125A 125

125

1

0.116

GAX41 040C 40

40

1

0.046

Type

cULus per UL98 / CSA C22.2 n°4 UL Listed (File E328470)

GAX41 125C 125

125

1

0.128

GAX41 040A-GAX42 040A





––

GAX41 063SA-GAX42 063SA





––

GAX41 040C-GAX42 040C





––

GAX41 125A-GAX42 125C



––



GAX42 063A...GAX42 125A



––



GAX42 063C...GAX42 125C



––



EAC

GAX42 040C GAX41 040C

cULus per UL508 / CSA C22.2 n°14 UL Listed (File E93602)

Early-make closing operation with respect to switch poles. For GA...A version.

For GA...C version.

     

For GA016 A-GA040 A only. For GA063 SA only. For GA016 C-GA040 C only. For GA063 A-GA125 A only. For GA063 C-GA125 C only. See page 11-4 for UL/CSA ratings which are the same as the corresponding switch types.

 Certification obtained.

Strokes of GA poles (switch and add-on pole) Travel 0→1 0° GA016A/C…GA040A/C - GA063SA Main poles GAX42040A/C - GAX42063SA Simultaneous fourth-pole add on GAX41040A/C-GAX41063SA Early-make fourth-pole add on

60° 60°

90°

Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, UL98, CSA C22.2.

60° 55°

55°

GA063A/C…GA125A/C Main poles GAX42063A/C…GAX42125A/C Simultaneous fourth-pole add on GAX41125A/C Early-make fourth-pole add on

55° 48° OFF

Add-on blocks/Accessories pages 11-6 to 10

30°

Dimensions pages 11-26 to 28

ON

Wiring diagrams page 11-50

Technical characteristics page 11-53

11-5

11

Switch disconnectors GA series 16A to 125A Add-on blocks and accessories Maximum combination

GA016 A...GA040 A Sequence and maximum combination of add-on blocks on direct operating switch disconnectors GA040 D

GAX31 A

GAX33 A

GAX10 11A

1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1

1 2 1 1 1 2 2 –– –– ––

GAX31 A

GAX33 A

GAX10 11A

1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1

1 2 1 1 1 2 2 –– –– ––

GAX32 A

GAX34 A

GAX10 11A

–– –– –– –– –– –– –– 1 1 1

–– –– –– –– –– –– –– 1 1 1

1 2 1 1 1 2 2 –– –– ––

GAX11 10EA GAX41 040A GAX42 040A GAX42 040D

–– –– –– 1 1 –– –– –– –– ––

 GAX42 040D can be used with GA040 D switch only.

1 –– 1 –– –– –– –– –– 1 ––

GAX41 040A GAX11 10EA GAX42 040A GAX42 040D

–– 1 –– 1 –– –– –– 1 –– ––

GA016 A GA025 A GA032 A GA040 A GA040 D

GAX10 11A

GAX33 A

GAX31 A

2 1 1 1 2 1 2 –– –– ––

1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1

GAX10 11A

GAX33 A

GAX31 A

2 1 1 1 2 1 2 –– –– ––

1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1

GAX10 11A

GAX34 A

GAX32 A

2 1 1 1 2 1 2 –– –– ––

–– –– –– –– –– –– –– 1 1 1

–– –– –– –– –– –– –– 1 1 1

–– –– 1 –– –– 1 –– –– –– ––

GA063 SA

11

GAX11 10EA GAX41 063SA GAX42 063SA

–– –– –– 1 1 –– –– –– –– ––

1 –– 1 –– –– –– –– –– 1 ––

GAX41 063SA GAX11 10EA GAX42 063SA

–– 1 –– 1 –– –– –– 1 –– ––

GA063 SA

–– –– 1 –– –– 1 –– –– –– ––

GA063 A...GA125 A GA080 D, GA125 D

GAX12 10EA GAX41 125A GAX42...A GA042 080D GA042 125D

–– –– –– 1 1 –– –– –– –– ––

 GAX42 080D can be used with GA080 D switch only.  GAX42 125D can be used with GA125 D switch only.

1 –– 1 –– –– –– –– –– 1 ––

GAX41 125A GAX12 10EA GAX42...A GA042 080D GA042 125D

–– 1 –– 1 –– –– –– 1 –– ––

GA063 A GA080 A GA100 A GA125 A GA080 D GA125 D

–– –– 1 –– –– 1 –– –– –– ––

GA016 C...GA040 C Sequence and maximum combination of add-on blocks on door mount switch disconnectors

GAX31 C

GAX33 C

GAX10 11C

GAX41 040C GAX42 040C

1 1 1 1 1 1

1 1 1 1 1 1

1 1 –– 1 1 ––

1 –– 1 –– –– ––

GAX32 C

GAX34 C

GAX10 11C

GAX41 125C GAX42 125C

–– –– 1 –– –– 1

–– –– 1 –– –– 1

1 1 –– 1 1 ––

1 –– 1 –– –– ––

GAX41 040C GAX42 040C

GAX10 11C

GAX33 C

GAX31 C

–– 1 –– 1 –– ––

1 1 1 –– 1 ––

1 1 1 1 1 1

1 1 1 1 1 1

GAX41 125C GAX42 125C

GAX10 11C

GAX34 C

GAX32 C

–– 1 –– 1 –– ––

1 1 1 –– 1 ––

–– –– –– 1 –– 1

–– –– –– 1 –– 1

GA016 C GA025 C GA032 C GA040 C

GA063 C...GA125 C

11-6

Add-on blocks/Accessories pages 11-6 to 10

Dimensions pages 11-26 to 28

GA063 C GA080 C GA100 C GA125 C

Wiring diagrams page 11-50

Technical characteristics pages 11-53

Switch disconnectors GA series 16A to 125A Add-on blocks and accessories GA016 A...GA040 A Sequence and maximum combination for mechanical coupling and mechanical interlock for line changeover GA040 D + GAX50 00 GAX60 00 GAX31 A

GAX33 A

GAX10 11A

GAX11 10EA GAX41 040A GAX42 040A GAX42 040D

1

1

1

––

1

1

1

1

––

1

1

1

2

––

––

1

1

1

––

1

1

1

1

1

––

1

1

1

1

––

1

1

2

––

––

1

1

2

––

––

1

1

––

––

1

1

1

––

––

––

GAX41 040A GAX11 10EA GAX42 040A GAX42 040D

GAX10 11A

GAX33 A

GAX31 A

GAX50 00 - GAX60 00

GA016 A + GA016 A + GA025 A + GA025 A + GA032 A + GA032 A + GA040 A + GA040 A + GA040 D + GA040 D 

1

––

1

1

1

––

––

2

1

1 1

1

––

1

1

––

1

1

1

1

1

––

1

1

1

––

––

2

1

1

––

1

1

1

1

––

––

2

1

1

1

––

––

1

1

––

––

––

1

1

GAX10 11A

GAX33 A

GAX31 A

 GAX42 040D can be used with GA040 D switch only. GA063 SA + GAX50 00 GAX60 00 GAX31 A

GAX33 A

GAX10 11A

GAX11 10EA GAX41 063SA GAX42 063SA

GAX41 063SA GAX11 10EA GAX42 063SA GAX50 00 - GAX60 00

1

1

1

––

1

1

––

1

1

1

1

1

1

––

1

––

––

2

1

1

1

1

2

––

––

1

––

1

1

1

1

1

1

––

1

––

1

1

1

1

1

1

1

1

––

1

––

1

1

1

1

1

1

1

––

––

––

2

1

1

1

1

2

––

––

––

1

1

1

1

1

1

2

––

––

––

––

2

1

1

GA063SA + GA063SA

1

1

––

––

1

1

––

––

1

1

1

1

––

––

––

––

––

––

1

1

GAX32 A

GAX34 A

GAX10 11A

GAX10 11A

GAX34 A

GAX32 A

––

––

1

––

1

––

––

––

1

––

1

––

––

2

––

––

––

––

1

––

1

––

––

1

1

––

GA063 A...GA125 A GA080 D, GA125 D + GAX50 01 GAX60 01 GAX12 10EA GAX41 125A GAX42...A GA042 080D GA042 125D

GAX41 125A GAX12 10EA GAX42...A GA042 080D GA042 125D

GAX50 01 - GAX60 01

––

––

1

1

––

––

––

2

––

––

––

––

2

––

––

1

1

––

––

1

1

1

––

––

––

GA063 A + GA063 A + GA080 A + GA080 A + GA100 A + GA100 A + GA125 A + GA125 A + GA080 D + GA080 D  GA125 D + GA125 D 

1

––

1

––

––

––

2

––

––

1

––

1

––

––

––

1

1

––

––

1

––

1

––

–– ––

––

––

2

––

––

1

1

––

––

––

––

2

––

––

1

––

––

1

1

––

––

––

1

1

 GAX42 080D can be used with GA080 D switch only.  GAX42 125D can be used with GA125 D switch only.

Add-on blocks/Accessories pages 11-6 to 10

Dimensions pages 11-26 to 28

Wiring diagrams page 11-50

Technical characteristics pages 11-53

11-7

11

Switch disconnectors GA series 16A to 125A Accessories Add-on blocks

Order code

Characteristics

Qty per pkg

Wt



[kg]

Auxiliary contacts, simultaneous operation as switch poles. GAX10 11A

1NO+1NC for GA...A, GA063 SA and GA...D

1

0.030

GAX10 11C

1NO+1NC for GA...C

1

0.030

Auxiliary contacts, early-break operation with respect to switch poles. GAX10 11A

GAX10 11C

GAX11 10EA 1EB (NO) for GA016 A-GA040 A, 1 GA063 SA and GA040 D

0.035

GAX12 10EA 1EB (NO) for GA063 A-GA125 A, 1 GA080 D and GA125 D

0.035

Neutral terminal.

GAX11 10EA GAX12 10EA

GAX31 A

For GA016 A-GA040 A, GA063 SA and GA040D

1

0.040

GAX32 A

For GA063 A-GA125 A and GA080 D - GA125 D

1

0.110

GAX31 C

For GA016 C-GA040 C

1

0.040

GAX32 C

For GA063 C-GA125 C

1

0.110

Operational characteristics of auxiliary contacts – IEC conventional free air thermal current Ith: 10A – UL/CSA and IEC/EN 60947-5-1 designation: A600-Q600 – Tightening torque: 0.8Nm/7.1lbin. Operational characteristics for other devices – Tightening torque: • GAX31A/C-GAX33A/C terminals: 1.8-2Nm/16-18lbin • GAX32A/C-GAX34A/C terminals: 5-6Nm/45-54lbin • GAX5000/5001-GAX6000/6001 fixing: 0.5Nm/4.4lbin; extension with handle: 0.8Nm/7.1lbin. Transformation of direct operating version into door coupling type GA016 A-GA040 A + GA016 A-GA040A / GA063 SA + GA063 SA / GA040 D + GA040 D with GAX50 00 for line changeover

GA063 A-GA125 A + GA063 A-GA124 A / GA080 D + GA080 D / GA125 D + GA125 D with GAX50 01 for line changeover

GAX7... (

0

5mm/02in)

Earth/Ground terminal. GAX33 A

For GA016 A-GA040 A, GA063 SA and GA...D

1

0.040

GAX34 A

For GA063 A-GA125 A and GA080 D - GA125 D

1

0.110

GAX33 C

For GA016 C-GA040 C

1

0.040

GAX34 C

For GA063 C-GA125 C

1

0.110

GAX67 B

0 II

11

Mechanical coupling system for 6-8 pole switch disconnectors.

Type

cULus per UL98 / CSA C22.2 n°4 UL Listed (File E328470)

GAX50... GAX60...

cULus per UL508 / CSA C22.2 n°14 UL Listed (File E93602)

Mechanical interlock for line changeover (I-0-II).

GAX3...C

GAX60 00

GAX10 11A - GAX10 11C





––

GAX11 10EA





––

GAX12 10EA





––

GAX31 A – GAX31 C





––

GAX32 A – GAX32 C



––



GAX33 A – GAX33 C





––

GAX34 A – GAX34 C



––



GAX50 00 – GAX60 00





––

GAX50 00

For GA016 A-GA040 A, 1 GA063 SA, GA...D and GAX67 B; 5mm/0.2” 

0.050

GAX50 01

For GA063 A-GA125 A, GA080 D 1 GA125 D and GAX67 B; 5mm/0.2” 

0.075

GAX60 01  

30°

60° 60°

90°

60°

Travel 1→0

GA063A/C…GA125A/C Main poles GAX10 11A – GAX10 11C Auxiliary contacts (1NO+1NC) NO NC

70° 55°

45°

Travel 1→0

Travel 0→1 0° GA040 D Main poles GA042 040D Simultaneous fourth-pole add on GAX10 11A Auxiliary contacts (1NO+1NC) NO NC

0.075

ON

30°

60° 60° 60°

Travel 1→0

Add-on blocks/Accessories pages 11-6 to 10

GAX50 01 – GAX60 01



––



GAX61-GAX61 B







GAX62-GAX62 B







GAX63-GAX63 B







GAX63 1B



––

––

GAX63 2-GAX63 2B







GAX64-GAX64 B







GAX66-GAX66 B



––



GAX67 B







GAX60 B



––



 Certification obtained.  UL Listed - cULus File E93601.

60°

NOTE: GAX61/61B and GAX66/66B are UL/CSA Type 1, 4, 4X outdoor use with all GA switch types. GAX62/62B, GAX63/63B, GAX632/2B, GAX64/64B and GAX67B are UL/CSA Type 1, 4, 4X outdoor use with GA016A/C-GA040A/C and GA063SA types, otherwise Type 1 only.

70° 55° 55°

Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, IEC/EN 60947-5-1, UL508, UL98, CSA C22.2.

45°

25° Travel 0→1 55°

GAX12 10EA Auxiliary contact (1EB – NO early break)

Travel 1→0

65°

OFF

11-8

90°

40° Travel 0→1 60°

GA080 D - GA125 D Main poles GAX42 080D - GAX42 125D Simultaneous fourth-pole add on GAX10 11A – GAX10 11C Auxiliary contacts (1NO+1NC) NO NC

65°

OFF

0.050

For GA063 A-GA125 A, GA080 D, 1 GA125 D; 7mm/0.3” 

GAX11 10EA Auxiliary contact (1EB – NO early break)

25° Travel 0→1 55°

GAX12 10EA Auxiliary contact (1EB – NO early break)

1

Strokes of GA…D types (switch and add-on blocks)

40° Travel 0→1 60°

GAX11 10EA Auxiliary contact (1EB – NO early break)

For GA016 A-GA040 A, GA063 SA and GA...D; 5mm/0.2” 

Use GAX7… shaft extensions. Use GAX66.. handles and GAX7…A extensions for a door-coupling version.

Strokes of GA poles (switch with auxiliary contact blocks) Travel 0→1 0° GA016A/C…GA040A/C - GA063SA Main poles GAX10 11A – GAX10 11C Auxiliary contacts (1NO+1NC) NO NC

Certifications and compliance Certifications obtained:

EAC

GAX3...A

I

Dimensions pages 11-26 to 28

ON

Wiring diagrams page 11-50

Switch disconnectors GA series 16A to 125A Accessories Rotary handles

Order code

Characteristics

Qty per pkg

Wt



[kg]

DOOR COUPLING HANDLES, PADLOCKABLE. Red/yellow, rotating.

GAX61

GAX62

GAX61

For GA...A, GA063 SA, GA...C and 1 GA...D. Screw fixing. Recessed selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.073

GAX62

For GA...A, GA063 SA, GA...C and 1 GA...D. Screw fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.072

GAX63

For GA...A, GA063 SA, 1 GA016 C - GA040 C and GA...D. Ring fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.068

For GA...A, GA063 SA, and GA...D. Low-profile ring fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.057

GAX63 2

GAX64

GAX66 GAX66

1

Operational characteristics – Choice of handle fixing: ring or screw – Fixing handle interaxis: 36x36mm/1.4x1.4” or 48x48mm/1.9x1.9” for GAX61/61B-GAX62/62BGAX67B; 36x36mm/1.4x1.4” for GAX66/66B Compatible with pre-existing drillings of most common types on marketplace – 1 to 3 padlocks (Ø4-8mm/Ø0.2-0.3”) for all handles – Tightening torque: • Fixing ring types: 2.3Nm/20.4lbin • GAX60B: 0.8Nm/7lbin • GAX66/66B: 1.5Nm/13.3lbin • All others: 1Nm/9lbin – Degree of protection: IEC/EN IP65 for all except GAX66/66B with IP66; for UL/CSA ratings, see note details on page 11-8. Transformation of direct operating version into door coupling type GA...A - GA063 SA GA...D

GAX7... (

5mm/0.2in) (GAX64/64B)

For GA...A, GA063 SA, and 1 GA...D. Ring fixing. Protruding selector with release, defeatable per UL508A; 5mm/0.2” . IEC IP65/UL Type 4X

0.064

For GA063 A-GA125 A, GA080 D, GA125 D and GAX60 01. Screw fixing. Pistol grip with release, defeatable per UL508A; 7mm/0.3” . IEC IP66/UL Type 4X

0.140

1

GAX63/63B GAX63 1B GAX63 2/2B GAX64/64B

(GAX63/63B) (GAX63 1B)

11

GAX62/62B

Black, rotating.

GAX63 B

GAX63 2B Low profile

GAX61 B

For GA...A, GA063 SA, GA...C and GA...D. Screw fixing. Recessed selector. 5mm/0.2” . IEC IP65/UL Type 4X

1

0.073

GAX62 B

For GA...A, GA063 SA, GA...C and 1 GA...D, Screw fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.072

GAX63 B

For GA...A, GA063 SA, 1 GA016 C - GA040 C and GA...D. Ring fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.068

GAX63 1B

For GA…A, GA063 SA, 1 GA016 C-GA040 C and GA…D. Ring fixing. Protruding selector, padlockable at ON (per UNI 9490 and UNI EN 12845 - firefighting systems); 5mm/0.2” . IEC IP65/UL Type 4X

0.074

For GA...A, GA063 SA and GA...D. 1 Low-profile ring fixing. Protruding selector. 5mm/0.2” . IEC IP65/UL Type 4X

0.057

For GA...A, GA063 SA and GA...D 1 Ring fixing. Protruding selector with release, defeatable per UL508A. 5mm/0.2” . IEC IP65/UL Type 4X

0.064

For GA063 A-GA125 A and 1 GA080 D-GA125 D and GAX60 01. Screw fixing. Pistol grip with release, defeatable per UL508A; 7mm/0.3” . IEC IP66/UL Type 4X

0.140

For GAX50... mechanical interlock mechanism (I-O-II). 5mm/0.2” . IEC IP65/UL Type 4X

0.078

GAX63 2B

GAX64 B

GAX66 B GAX67 B

GAX67 B

  

For GA...A and GA...D switch disconnectors, separately purchase GAX7... shaft extensions. Snap-on fixing of GA016-GA040C switch disconnectors with the handle. Separately purchase GAX7…A shaft extension and GAX60 B handle having a 7mm/0.3” square section, nor required for GAX60 01.

1

GAX61/61B

GA080 D + GA080 D / GA125 D + GA125 D with GAX60 01 for 6 and 8 poles

GA080 D GA125 D

GAX60 B

GAX7150A GAX7200A GAX7300A ( 7mm/0.3”)

GAX66 GAX66 B

Door-mount version GA016 C - GA040 C

GAX63/63B GAX63 1B

GA016 C - GA040 C

GA063 C - GA125 C

GAX61/61B

GAX62/62B

ACCESSORIES FOR DOOR COUPLING CONTROL. For GAX66 and GAX66 B handles. GAX60 B

Adapter 7mm/0.3” for GA063 A-GA125 A, GA080 D and GA125 D Dimensions pages 11-26 to 28

1

0.010 Certifications and compliance See the table on page 11-8 for details.

11-9

Switch disconnectors GA series 16A to 125A Accessories Characteristics

Qty per pkg

Wt



[kg]

Shaft extension for door-coupling handles GAX61-GAX64, GAX61 B-GAX64 B, GAX67 B and mechanical interlock type GAX50 00, GAX50 01 and coupling system GAX60 00. 55mm long; 5mm/0.2” 70mm long; 5mm/0.2”

1

0,012

GAX7 070

1

0.014

GAX7 090

90mm long; 5mm/0.2”

1

0.018

GAX7 150

150mm long; 5mm/0.2”

1

0.032

GAX7 200

200mm long; 5mm/0.2”

1

0.040

GAX7 300

300mm long; 5mm/0.2”

1

0.068

GAX7 400

400mm long; 5mm/0.2”

1

0.072

GAX7 500

500mm long; 5mm/0.2”

1

0.090

GAX7 055

GAX7...

Shaft extension for door-coupling handles GAX66, GAX66 B and mechanical coupling system GAX60 01.

GAX7... A

GAX7 150A

150mm long; 7mm/0.3”

1

0.090

GAX7 200A

200mm long; 7mm/0.3” 300mm long; 7mm/0.3”

1

0.112

1

0.160

GAX7 300A

GAX8...

Terminal covers For switch disconnectors

GA...A GA063 SA GA...D GAX83 GAX84 GAX83 GAX84 GA...C

For fourth pole

Set of 2 one-pole terminal covers for fourth pole. GAX81

For GAX42 040A, GAX42 040C GAX42 040D, GAX41 040A, GAX41 040C, GAX41 063SA, GAX42 063SA

1

0.009

GAX82

For GAX42 063A-GAX42 125A, GAX42 063C-GAX42 125C, GAX42 080D, GAX42 125D, GAX41 125A, GAX41 125C

1

0.012

11

Operational characteristics of fuse holder – IEC rated insulation voltage Ui: 1000V – IEC rated impulse withstand voltage Uimp: 8kV – The fuse holder/block connects directly to the switch disconnectors. – Access to fuses only when the switch disconnectors are in OFF position.

GAX41...A GAX41 063SA GAX42...A GAX42 063SA GAX42...D

GAX81 GAX82

GAX81 GAX82 GAX41...C GAX42...C

Set of 2 three-pole terminal covers. GAX83

For GA016 A-GA040 A, GA063 SA, GA016 C-GA040 C, GA040 D

1

0.018

GAX84

For GA063 A-GA125 A, GA063 C-GA125 C, GA080 D, GA125 D

1

0.030

Certifications and compliance Certifications obtained:

GAX39 1

For GA016 A-GA032 A Suitable for 10.3x38 fuse size

1

0.132

GAX39 1UL

For GA016 A-GA025 A Suitable for Class CC fuses

1

0.135

GAX39 1

EAC

Fuse holder/block for switch disconnectors.

Type

cULus per UL98 / CSA C22.2 n°4 UL Listed (File E328470)

Order code

cULus per UL508 / CSA C22.2 n°14 UL Listed (File E93602)

Shaft extensions Terminal covers Fuse holders/blocks

GAX7 055…GAX7 500







GAX7 150A … GAX7 300A



––



GAX81-GAX83





––

GAX82-GAX84



––



GAX39 1



––

––

GAX39 1UL

––



––

 Certification obtained. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, UL98, CSA C22.2.

11-10

Dimensions pages 11-26 to 28

Wiring diagrams page 11-50

Switch disconnectors GA series 16A to 125A Empty non-metallic enclosures IEC/EN type IP65

Order code

Description

Qty per pkg

Wt



[kg]

For switch disconnectors. With rotating red/yellow handle. Complete with shaft extension.

GAZ1

GAZ1

For GA016 A-GA040 A and GA040 D

1

0.320

GAZ2

For GA063 SA, 1 GA063 A-GA100 A and GA080 D

0.780

GAZ3

For GA125 A and GA125 D

1.900

1

With rotating black handle. Complete with shaft extension.

GAZ2

GAZ1 B

For GA016 A-GA040 A and GA040 D

1

0.320

GAZ2 B

For GA063 SA, 1 GA063 A-GA100 A and GA080 D

0.780

GAZ3 B

For GA125 A and GA125 D

1.900

1

General characteristics – Enclosure material: ABS – Padlockable handle – Sealable cover – For GAZ3/3B if any earth/ground and/or neutral terminal required, separately purchase types GAX3… given on page 11-8 – Tightening torque for cover screws: • GAZ1/1B: 1.3Nm/16lbin • Other types: 1.5Nm/13lbin – IEC/EN degree of protection: IP65 – Cable entry: • GAZ1/1B: PG16/M25 and PG13.5/M20 knockouts • GAX2/2B: PG29/M32 and PG16/M25 knockouts • GAZ3/3B: Smooth surfaces; can be drilled by customer. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

The empty enclosures are supplied with the following accessories: Enclosure

GAZ1 GAZ1B

GAZ2 GAZ2B

GAZ3 GAZ3B

Red/yellow handle

GAX61

GAX61

GAX61

Black handle

GAX61B

GAX61B

GAX61B

Extension

1

1

1

Neutral plate terminal

1

1

-

Earth/Ground plate terminal

1

1

-

11

GAZ3

UL/CSA Type 4/4X

Order code

Description

Qty per pkg

Wt



[kg]

For switch disconnectors. With rotating red/yellow handle. Complete with shaft extension.

GAZ1 UL

GAZ1 UL

For GA016 A-GA040 A and GA040D

1

0.320

GAZ2 UL

For GA063 SA and GA063 A

1

0.730

GAZ3 UL

For GA80 A-GA125 A, GA080 D and GA125 D

1

1.900

With rotating black handle. Complete with shaft extension.

GAZ2 UL

GAZ1 B UL

For GA016 A-GA040 A and GA040D

1

0.320

GAZ2 B UL

For GA063 SA and GA063 A

1

0.730

GAZ3 B UL

For GA80 A-GA125 A, GA080 D and GA125 D

1

1.900

The empty enclosures are supplied with the following accessories: Enclosure

GAZ1UL GAZ2UL GAZ3UL GAZ1BUL GAZ2BUL GAX3BUL

Red/yellow handle

GAX61

GAX61

GAX61

Black handle

GAX61B

GAX61B

GAX61B

Extension

1

1

1

Neutral plate terminal

1

1

1

Earth/Ground plate terminal

1

1

1

General characteristics – Enclosure material: Polycarbonate – Padlockable handle – Sealable cover – Tightening torque for enclosure screws: • GAZ1/1B UL: 1.3Nm/16lbin for cover; 1.2Nm/11lbin for plate terminals • Other types: 1.5Nm/13lbin for cover; 1.2Nm/11lbin for plate terminals – UL/CSA degree of protection: Type 1, 4 and 4X indoor use only for GAZ1 UL; not available for others / testing pending completion at time of catalogue printing – Cable entry: • GAZ1/1B UL: PG16/M25 and PG13.5/M20 knockouts • GAX2/2B UL: PG29/M32 and PG16/M25 knockouts • GAZ3/3B UL: Smooth surfaces; can be drilled by customer. Certifications and compliance Certifications obtained: EAC, UL Listed for USA and Canada (cULus – file E93602) as Polymeric Enclosures for Manual Motor Controllers; cCSAus pending for GAZ2/2B UL and GAZ3/3B UL at time of catalogue printing. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, CSA C22.2 n°14, UL98, CSA C22.2 n°4.

GAZ3 UL

Dimensions page 11-28

Wiring diagrams page 11-50

11-11

Switch disconnectors GA series 16A to 125A Enclosed switch disconnectors IEC/EN type IP65 non-metallic enclosure

Order code

IEC conventional free air thermal Qty current Ith per AC21A (690V) pkg

Wt

[A]



[kg]

Components Enclosure Switch disconnector

Handle

THREE POLE. With rotating red/yellow handle.

GAZ016...GAZ040...

GAZ016

16

1

0.450

GAZ1

GA016 A

GAX61

GAZ025

25

1

0.450

GAZ1

GA025 A

GAX61

GAZ032

32

1

0.450

GAZ1

GA032 A

GAX61

GAZ040

40

1

0.450

GAZ1

GA040 A

GAX61

GAZ063 SA

63

1

0.870

GAZ2

GA063 SA

GAX61

GAZ063 C

63

1

1.220

GAZ2

GA063 A

GAX61

GAZ080 C

80

1

1.220

GAZ2

GA080 A

GAX61

GAZ100 C

100

1

1.220

GAZ2

GA100 A

GAX61

GAZ125

125

1

2.220

GAZ3

GA125 A

GAX61

With rotating black handle.

GAZ063...100 C

11

GAZ016 B

16

1

0.450

GAZ1 B

GA016 A

GAX61 B

GAZ025 B

25

1

0.450

GAZ1 B

GA025 A

GAX61 B

GAZ032 B

32

1

0.450

GAZ1 B

GA032 A

GAX61 B

GAZ040 B

40

1

0.450

GAZ1 B

GA040 A

GAX61 B

GAZ063 SAB 63

1

0.870

GAZ2 B

GA063 SA

GAX61 B

GAZ063 CB

63

1

1.220

GAZ2 B

GA063 A

GAX61 B

GAZ080 CB

80

1

1.220

GAZ2 B

GA080 A

GAX61 B

GAZ100 CB

100

1

1.220

GAZ2 B

GA100 A

GAX61 B

GAZ125 B

125

1

2.220

GAZ3 B

GA125 A

GAX61 B

Enclosure

Switch Fourth disconnector pole

Handle

FOUR POLE. With rotating red/yellow handle. GAZ016 T4

16

1

0.550

GAZ1

GA016 A

GAX42040A

GAX61

GAZ032 T4

32

1

0.550

GAZ1

GA032 A

GAX42040A

GAX61

GAZ063 CT4 63

1

1.250

GAZ2

GA063 A

GAX42063A

GAX61

GAZ100 CT4 100

1

1.250

GAZ2

GA100 A

GAX42100A

GAX61

GAZ125 T4

1

2.500

GAZ3

GA125 A

GAX42125A

GAX61

GAZ016 T4B 16

1

0.550

GAZ1 B

GA016 A

GAX42040A

GAX61 B

GAZ032 T4B 32

1

0.550

GAZ1 B

GA032 A

GAX42040A

GAX61 B

GAZ063 CT4B 63

1

1.250

GAZ2 B

GA063 A

GAX42063A

GAX61 B

GAZ100 CT4B 100

1

1.250

GAZ2 B

GA100 A

GAX42100A

GAX61 B

GAZ125 T4B 125

1

2.500

GAZ3 B

GA125 A

GAX42125A

GAX61 B

125

With rotating black handle.

GAZ125...

General characteristics – Enclosure material: ABS – For four-pole types not indicated, separately purchase corresponding fourth pole GAX42…A and install on enclosed 3-pole version – Possible accessories to mount afterwards, if any required: • GAZ016-GAZ040 types: 1 contact block both on the right and left disconnector side unless 4th pole is installed • All other types: 2 contact blocks both on the right and left disconnector side unless 4th pole is installed • For GAZ125 types: if any earth/ground and/or neutral terminal required, separately purchase types GAX3… given on page 11-8 – Padlockable handle – Sealable cover – Tightening torque for cover screws: • GAZ016-GAZ040 types: 1.3Nm/16lbin • All other types: 1.5Nm/13lbin – IEC/EN degree of protection: IP65 – Cable entry: • GAZ016-GAZ040 types: PG16/M25 and PG13.5/M20 knockouts • GAZ063SA-GAZ100 types: PG29/M32 and PG16/M25 knockouts • GAZ125 types: Smooth surfaces; can be drilled by customer. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC7EN 60947-1, IEC/EN 60947-3.

11-12

Dimensions page 11-28

Wiring diagrams page 11-50

Technical characteristics page 11-53

Switch disconnectors GA series 16A to 125A Enclosed switch disconnectors UL/CSA Type 4/4X non-metallic enclosure

Order code

Description

Qty per pkg

Wt



[kg]

Components Enclosure Switch disconnector

Handle

THREE POLE. With rotating red/yellow handle.

GAZ016...GAZ040...UL

GAZ016 UL

16

1

0.450

GAZ1 UL

GA016 A

GAX61

GAZ025 UL

25

1

0.450

GAZ1 UL

GA025 A

GAX61

GAZ032 UL

32

1

0.450

GAZ1 UL

GA032 A

GAX61

GAZ040 UL

40

1

0.450

GAZ1 UL

GA040 A

GAX61

GAZ063 SA UL

63

1

0.870

GAZ2 UL

GA063 SA

GAX61

GAZ063 CUL

63

1

1.220

GAZ2 UL

GA063 A

GAX61

GAZ080 UL

80

1

2.220

GAZ3 UL

GA080 A

GAX61

GAZ100 UL

100

1

2.220

GAZ3 UL

GA100 A

GAX61

GAZ125 UL

125

1

2.220

GAZ3 UL

GA125 A

GAX61

With rotating black handle.

GAZ063 SAB UL GAZ063 CB UL

GAZ016 BUL

16

1

0.450

GAZ1 B UL

GA016 A

GAX61 B

GAZ025 BUL

25

1

0.450

GAZ1 B UL

GA025 A

GAX61 B

GAZ032 BUL

32

1

0.450

GAZ1 B UL

GA032 A

GAX61 B

GAZ040 BUL

40

1

0.450

GAZ1 B UL

GA040 A

GAX61 B

GAZ063 SAB UL 63

1

0.870

GAZ2 B UL

GA063 SA

GAX61 B

GAZ063 CB UL

63

1

1.220

GAZ2 B UL

GA063 A

GAX61 B

GAZ080 B UL

80

1

2.220

GAZ3 B UL

GA080 A

GAX61 B

GAZ100 B UL

100

1

2.220

GAZ3 B UL

GA100 A

GAX61 B

GAZ125 B UL

125

1

2.220

GAZ3 B UL

GA125 A

GAX61 B

Enclosure

Switch Fourth disconnector pole

Handle

FOUR POLE. With rotating red/yellow handle. GAZ016 T4 UL

16

1

0.550

GAZ1 UL

GA016 A

GAX42040A

GAX61

GAZ032 T4 UL

32

1

0.550

GAZ1 UL

GA032 A

GAX42040A

GAX61

GAZ063 CT4 UL 63

1

1.150

GAZ2 UL

GA063 A

GAX42063A

GAX61

GAZ100 T4 UL

100

1

2.500

GAZ3 UL

GA100 A

GAX42100A

GAX61

GAZ125 T4 UL

125

1

2.500

GAZ3 UL

GA125 A

GAX42125A

GAX61

GAZ016 T4B UL 16

1

0.550

GAZ1 B UL

GA016 A

GAX42040A

GAX61 B

GAZ032 T4B UL 32

1

0.550

GAZ1 B UL

GA032 A

GAX42040A

GAX61 B

GAZ063 CT4B UL 63

1

1.150

GAZ2 B UL

GA063 A

GAX42063A

GAX61 B

GAZ100 T4B UL

100

1

2.500

GAZ3 B UL

GA100 A

GAX42100A

GAX61 B

GAZ125 T4B UL 125

1

2.500

GAZ3 B UL

GA125 A

GAX42125A

GAX61 B

With rotating black handle.

GAZ100 UL - GAZ125 UL

UL/CSA ratings Type

1 phase [HP]

120V

3 phase [HP]

General use at 600VAC

Shortcircuit rating at 600VAC

Fuse class max rating at 600V

240V

200208V

240V

480V

600V

[A]

[kA]

Type - [A] RK5 - 20A

GAZ016... 1

2

5

5

10

10

16

5

GAZ025... 11/2

3

71/2

71/2

15

20

25

5

RK5 - 30A

GAZ032... 2

5

10

10

20

20

32

5

RK5 - 35A

GAZ040... 2

5

10

15

20

25

40

5

RK5 - 45A

GAZ063S... 2

71/2

10

15

30

30

60

5

RK5 - 45A

NOTE: Above ratings are valid for GAZ016 - GAZ063S...UL types, according to UL508 and CSA 22.2 n°14. UL Listed for USA and Canada (cULus - File E93602), as Manual Motor Controllers while UL designation is “GENERAL PURPOSE SWITCH. INTERRUPTEUR USAGE GENERAL” and “SUITABLE AS MOTOR DISCONNECT”; GAZ063S... pending.

Type



1 phase [HP]

120V

3 phase [HP]

240V

200240V 208V

480V

600V

General use at 600VAC

Shortcircuit rating at 600VAC

Max fuse rating at 600V

[A]

[kA]

[A]

GAZ063C... 3

71/2

20

20

40

40

60

10

100

GAZ080... 3

10

25

25

40

40

100

10

100

GAZ100... 5

10

30

30

50

50

100

10

100

GAZ125... 71/2

10

30

30

60

60

100

10

100

NOTE: Above ratings are valid for GAZ063C - GAZ125... types, according to UL98 and CSA C22.2 n°4. For indication and reference purposes only while cCSAus is pending.  Lower ratings in this same UL/CSA category are available on specific request for volume orders. For information, consult Customer Service; see contact details on inside front cover.  Voltage value not considered in UL98 / CSA 22.2 n°4 standards.

Dimensions page 11-28

Wiring diagrams page 11-50

General characteristics – Enclosure material: Polycarbonate – For four-pole types not indicated, separately purchase corresponding fourth pole GAX42…A and install on enclosed 3-pole UL-suffix version – Possible accessories to mount afterwards, if any required: • GAZ016-040…UL types: 1 contact block on both the right and left disconnector side unless 4th pole is installed • All other types: 2 contact blocks both on the right and left disconnector side unless 4th pole is installed – Padlockable handle – Sealable cover – Tightening torque for enclosure screws: • GAZ016-040…UL: 1.3Nm/16lbin for cover; 1.2Nm/11lbin for plate terminals • Other types: 1.5Nm/13lbin for cover; 1.2Nm/11lbin for plate terminals – UL/CSA degree of protection: Type 1, 4 and 4X indoor use only for GAZ016-040…UL types; not available for others / testing pending completion at time of catalogue printing – Cable entry: • GAZ016-040…UL: PG16/M25 and PG13.5/M20 knockouts • GAX063…UL: PG29/M32 and PG16/M25 knockouts • GAZ0100-125…UL: Smooth surfaces; can be drilled by customer. Certifications and compliance Certifications obtained: EAC, UL Listed for USA and Canada (cULus – file E93602), as Manual Motor Controllers – Enclosed for GAZ016-040…UL types; cCSAus pending for all others at time of catalogue printing. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3; UL508 and CSA C22.2 n°14 up to GAZ063S…; UL98 and CSA C22.2 n°4 for all others. Technical characteristics page 11-53

11-13

11

Switch disconnectors GA series 16A to 125A Enclosed changeover switches UL/CSA Type 4/4X non-metallic enclosure

Order code

IEC conventional free air thermal current Ith AC21A (690V)

IEC rated operational current Ie

Qty Wt per pkg

AC22A AC23B (400V) (500V)

[A]

[A]

[A]



[kg]

Components Enclosure 3-pole switch disconnector

Interlock

Handle

Three-pole line changeover switches I-0-II. 25

25

25

1

1.060

GAZ UL

2x GA025A

GAX5000

GAX67 B

GAZ040 ET6

40

40

25

1

1.060

GAZ UL

2x GA040A

GAX5000

GAX67 B

GAZ063SA ET6 63

45

25

1

1.070

GAZ UL

2x GA063SA

GAX5000

GAX67 B

GAZ080 ET6

80

80

63

1

2.950

GAZ3UL

2x GA080A

GAX5001

GAX67 B

GAZ125 ET6

125

125

100

1

2.950

GAZ3UL

2x GA125A

GAX5001

GAX67 B

Enclosure

Switch disconnector + 4th pole

Interlock

Handle

Four-pole line changeover switches I-0-II.

GAZ 025 E...GAZ 063SA E...

11

GAZ025 ET6

GAZ025 ET8

25

25

25

1

1.060

GAZ UL

2x GA025A + 2x GAX42040A

GAX5000

GAX67 B

GAZ040 ET8

40

40

25

1

1.060

GAZ UL

2x GA040A+ 2x GAX42040A

GAX5000

GAX67 B

GAZ063SA ET8 63

45

25

1

1.070

GAZ UL

2x GA063SA+ GAX5000 2x GAX42063SA

GAX67 B

GAZ080 ET8

80

80

63

1

2.950

GAZ3UL

2x GA080A+ 2x GAX42080A

GAX5001

GAX67 B

GAZ125 ET8

125

125

100

1

2.950

GAZ3UL

2x GA125A+ 2x GAX42125A

GAX5001

GAX67 B

 GAZ 080 E... GAZ 125 E...

UL/CSA ratings Type

1 phase [HP]

120V

3 phase [HP]

240V

200208V

240V

480V

600V

General use at 600VAC

Shortcircuit rating at 600VAC

Fuse class max rating at 600V

[A]

[kA]

Type - [A]

GAZ025... 11/2

3

71/2

71/2

15

20

25

5

RK5 - 30A

GAZ040... 2

5

10

15

20

25

40

5

RK5 - 45A

GAZ063S... 2

71/2

10

15

30

30

60

5

RK5 - 45A

NOTE: Above ratings are valid for GAZ025-GAZ040ET... types, according to UL508 and CSA 22.2 n°14. For indication and references purposes only while cCSAus is pending.

Type

1 phase [HP]

120V

3 phase [HP]

240V

200240V 208V

480V

600V

General use at 600VAC

Shortcircuit rating at 600VAC

Max fuse rating at 600V

[A]

[kA]

[A]

GA080...

3

10

25

25

40

40

100

10

100

GA125...

71/2

10

30

30

60

60

100

10

100

For major details, consult Customer Service; see contact details on inside front cover.

General characteristics – Enclosure material: Polycarbonate – Possible accessories to mount afterwards, if any required: • 2 contact blocks both on the right and left side for GAZ…ET6 types • 1 contact block both on the right and left side for GAZ…ET8 types – Complete with neutral and earth/ground plate terminals – Sealable cover – Padlockable handle, complete with shaft extension – Tightening torque for enclosure screws: • 1.5Nm/13lbin for cover • 1.2Nm/11lbin for plate terminals – Degree of protection: IEC/EN IP65; UL/CSA Type 1, 4 and 4X indoor use only – Cable entry: • GAZ025-063…ET6/8: PG29/M32 and PG16/M25 knockouts • GAZ080-125 ET6/8: Smooth surfaces; can be drilled by customer. Certifications and compliance Certifications pending: EAC, cCSAus. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3; CSA C22.2 n°14 and UL508 up to GAZ063…ET6/8; CSA C22.2 n°4 and UL98 for GAZ100-125 ET6/8

NOTE: Above ratings are valid for GAZ080-GAZ125ET... types, according to UL98 and CSA C22.2 N°4. For indication and references purposes only while cCSAus is pending.  Voltage value not considered in UL98 / CSA 22.2 n°4 standards so not indicated in UL product marking.

11-14

Dimensions page 11-29

Wiring diagrams page 11-50

Technical characteristics pages 11-53

Switch disconnectors GA series 16A to 125A

Maximum combination Enclosures

GAX10 11A

GAX10 11A

GAX81

GAX42 063SA GAX41 063SA or GAX11 10EA

GAX81

GAX42 040A GAX41 040A GAX42 040D or GAX11 10EA GAX83

GAX83 GAZ016...GAZ040 GAZ016 B...GAZ040 B GAZ1 GAZ1 B

GAZ063 SA GAZ063 SAB GAZ2 GAZ2 B

One auxiliary contact block can be fitted on the right and left sides of the disconnector unless the fourth pole is installed. The earth and neutral plate terminals are standard supplied on the enclosure base.

Sealing eyelet

Two auxiliary contacts blocks can be fitted both on the right and left sides of the disconnector unless the fourth pole is installed. Earth/ground and neutral plate terminals are standard supplied on the enclosure base.

11

GAX12 10EA or GAX12 10EA or

GAX34A

GAX10 11A

GAX34A

GAX32A GAX10 11A

GAX32A

GAX83

GAX41 125A GAX42 063A... GAX42 125A GAX42 080D GAX42 125D

GAX83 GAX41 125A GAX42 125A GAX42 125D GAX84

GAX84

GAZ063...GAZ100C GAZ063...GAZ100CB GAZ2 GAZ2 B GAZ125 GAZ125 B GAZ3 GAZ3 B

Two auxiliary contact blocks can be fitted both on the right and left sides of the disconnector unless the fourth pole is installed. Earth/ground and neutral terminals, GAX... type, if any required, are to be purchased separately for the enclosure except for GAZ...UL types which have plate terminals standard supplied.

Dimensions page 11-28

Wiring diagrams page 11-50

Technical characteristics pages 11-53

11-15

Switch disconnectors GE series 50A to 1600A Three-pole switch disconnectors

Order code IEC conventional free air thermal current Ith AC21A (500V)

IEC rated operational current Ie

Qty Wt per pkg

AC23A AC23A (400V) (500V)

Selection of handle and accessories Types of handle to use per type are given below. Also refer to pages 11-19 and 11-22 for other accessories.

Direct operating

Door coupling

Black

Black

Red/yellow

GEX65D

GAX66B

GAX66

GEX66ND

GEX66NB

GEX66N

GEX67ND

GEX67NB

GEX67N

GEX68ND

GEX68NB

GEX68N

With NFC fuse holder . Separately purchase the handle and shaft extension .

Direct operating Black

Door coupling Black

Red/yellow

GE0050 F 50

50

50

1

1.250

GEX61D

GEX61NB

GEX61N

GE0125 F 125

125

125

1

1.700

With NH fuse holder . Separately purchase the handle and shaft extension.

Direct operating Black

Door coupling Black

Red/yellow

GE0160 N

160

160

125

1

1.700

GEX61D

GEX61NB

GEX61N

GE0161 N

160

160

160

1

3.100

GEX62D

GEX66NB

GEX66N

GE0250 N

250

250

250

1

6.600

GEX63D

GEX67NB

GEX67N

GE0400 N

400

400

400

1

6.600

GE0630 N

630

630

630

1

13.000

GEX64D

GEX68NB

GEX68N

GE0800 N

800

630

630

1

13.000

With BS fuse holder . Separately purchase the handle and shaft extension.

Direct operating Black

Door coupling Black

Red/yellow

GE0160 B

160

160

160

1

3.500

GEX62D

GEX66NB

GEX66N

GE0200 B

200

200

200

1

3.500

GE0250 B

250

250

250

1

6.600

GE0315 B

315

315

315

1

6.600

GEX63D

GEX67NB

GEX67N

GE0400 B

400

400

400

1

6.600

GE0630 B

630

630

630

1

13.000

GEX64D

GEX68NB

GEX68N

GE0800 B

800

630

630

1

13.000

[A]

[A]

[A]



[kg]

Separately purchase the handle and shaft extension .

GE...

11

Three-pole switch disconnectors with fuse holder

GE... F - GE...N - GE...B

GE0160 P 160

160

125

1

0.850

GE0160

160

160

125

1

0.850

GE0200

200

160

125

1

0.900

GE0250

250

160

125

1

0.900

GE0251

250

250

200

1

1.700

GE0315

315

315

250

1

1.700

GE0400

400

400

315

1

1.900

GE0500

500

500

400

1

4.200

GE0630

630

630

500

1

4.200

GE0800

800

800

500

1

4.200

GE1000

1000

800

800

1

7.600

GE1250

1250

800

800

1

7.600

GE1600

1600

1000

900

1

20.800



Refer to the side table for the selection of the handle. A shaft insert is standard-supplied with all direct operating handles so no other shaft extension is required in this case.  See table on page 11-22 also for the types of fuses.  The switch disconnector is standard-supplied with fuse protection shield.  Standard supplied with IEC IP20 terminal protection.  IEC 250A Ith; IEC 200A AC21A 500V.

General characteristics – IEC 50A to 1600A ratings – Available versions: direct operating and door coupling – Screw fixing: 35mm DIN rail mount adapter kit for GE0160 P on p. 11-19 – Padlockable at 0 position with no extra accessory. Operational characteristics – IEC rated insulation voltage Ui: • 1000V for GE0160 P, GE0160-GE1600, GE0250 N/B-GE0800 N/B • 800V for GE0050 F, GE0125 F, GE0160 N/B, GE0161 N, and GE0200 B – Mechanical life: • 30,000 cycles for GE0160 P, GE0160-GE0250, • 20,000 cycles for GE0251-GE0400 • 10,000 cycles for GE0500-GE1600, GE0050 F, GE0125 F, GE0160 N/B-GE0400 N/B • 5,000 cycles for GE0630 N/B-GE0800 N/B. Certifications and compliance Certificatons obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

11-16

Add-on blocks/Accessories pages 11-19 to 22

Dimensions pages 11-30 to 42

Wiring diagrams page 11-51

Technical characteristics pages 11-54 and 56

Switch disconnectors GE series 50A to 1600A Four-pole switch disconnectors

Order code

IEC conventional free air thermal current Ith AC21A (500V)

IEC rated operational current Ie

[A]

[A]

Qty Wt per pkg

AC23A AC23A (400V) (500V)

Selection of handles and accessories Types of handle to use per type are given below. Also refer to pages 11-19 and 11-23 for other accessories. Direct operating

Door coupling

Black

Black

Red/yellow

GEX65D

GAX66B

GAX66

GEX66ND

GEX66NB

GEX66N

GEX67ND

GEX67NB

GEX67N

GEX68ND

GEX68NB

GEX68N

With NFC fuse holder . Separately purchase the handle and shaft extension .

Direct actuator Black

Door coupling Black

Red/yellow

GE0050 FT4 50

50

50

1

1.250

GEX61D

GEX61NB

GEX61N

GE0125 FT4 125

125

125

1

1.700

With NH fuse holder . Separately purchase the handle and shaft extension .

Direct actuator Black

Door coupling Black

Red/yellow

GE0160 NT4

160

160

125

1

2.200

GEX61D

GEX61NB

GEX61N

GE0161 NT4

160

160

160

1

8.000

GEX62D

GEX66NB

GEX66N

GE0250 NT4

250

250

250

1

8.000

GEX63D

GEX67NB

GEX67N

GE0400 NT4

400

400

400

1

8.000

GE0630 NT4

630

630

630

1

15.000

GEX64D

GEX68NB

GEX68N

GE0800 NT4

800

630

630

1

15.000

With BS fuse holder . Separately purchase the handle and shaft extension.

Direct actuator Black

Door coupling Black

Red/yellow

GE0160 BT4

160

160

160

1

4.000

GEX62D

GEX66NB

GEX66N

GE0200 BT4

200

200

200

1

4.000

GE0250 BT4

250

250

250

1

4.000

GE0315 BT4

315

315

315

1

8.000

GEX63D

GEX67NB

GEX67N

GE0400 BT4

400

400

400

1

8.000

GE0630 BT4

630

630

630

1

15.000

GEX64D

GEX68NB

GEX68N

GE0800 BT4

800

630

630

1

15.000

[A]



[kg]

Separately purchase the handle and shaft extension .

GE...T4...

Four-pole switch disconnectors with fuse holder

GE... FT4 - GE...NT4-GE...BT4

GE0160 T4P 160

160

125

1

1.000

GE0160 T4

160

160

125

1

1.000

GE0200 T4

200

160

125

1

1.000

GE0250 T4

250

160

125

1

1.000

GE0251 T4

250

250

200

1

1.900

GE0315 T4

315

315

250

1

1.900

GE0400 T4

400

400

315

1

2.100

GE0500 T4

500

500

400

1

4.500

GE0630 T4

630

630

500

1

4.500

GE0800 T4

800

800

500

1

4.500

GE1000 T4

1000

800

800

1

7.600

GE1250 T4

1250

800

800

1

7.600

GE1600 T4

1600

1000

900

1

20.800

    

Refer to the side table for the selection of the handle. A shaft insert is standard-supplied with all direct operating handles so no other shaft extension is required in this case. See table on page 11-23 also for the types of fuses. The switch disconnector is standard-supplied with fuse protection shield. Standard supplied with IEC IP20 terminal protection. IEC 250A Ith; IEC 200A AC21A 500V.

11

General characteristics – IEC 50A to 1600A ratings – 4-pole types (3P+N) with early-make late-break neutral pole – Available versions: direct operating and door coupling – Screw fixing: 35mm DIN rail mount adapter kit for GE0160 T4P on p. 11-19 – Padlockable at 0 position with no extra accessory. Operational characteristics – IEC rated insulation voltage Ui: • 1000V for GE1600 T4P, GE0160 T4-GE1600 T4, GE0250 NT4/BT4-GE0800 NT4/BT4 • 800V for GE0050 FT4, GE0125 FT4, GE0160 NT4/BT4, GE0161 NT, GE0200 BT4 – Mechanical life: • 30,000 cycles for GE1600 T4P, GE0160 T4GE0250 T4 • 20,000 cycles for GE0251 T4-GE0400 T4 • 10,000 cycles for GE0500 T4-GE1600 T4, GE0050 FT4, GE0125 FT4, GE0160 NT4/BT4-GE0400 NT4/BT4 • 5,000 cycles for GE0630 NT4/BT4, GE0800 NT4/BT4. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

Add-on blocks/Accessories pages 11-19 to 23

Dimensions pages 11-30 to 42

Wiring diagrams page 11-51

Technical characteristics pages 11-54 and 56

11-17

Switch disconnectors GE series 50A to 1600A Changeover switches Three-pole changeover switches

Order code

IEC conventional free air thermal current Ith AC21A (500V)

IEC rated operational current Ie AC23B AC23B (400V) (500V)

[A]

[A]

[A]

Qty Wt per pkg



[kg]

Selection of handles and accessories Types of handle to use per type are given below. Also refer to pages 11-19 and 11-21 for other accessories. Direct actuator

Door coupling

Black

Black

GEX61E

GEX61NC

GEX62NE

GEX62NC

GEX63NE

GEX63NC

GEX64NE

GEX64NC

Separately purchase the handle and shaft extension.

GE...E

Four-pole changeover switches

GE0160 E

160

160

125

1

1.800

GE0200 E

200

160

125

1

1.900

GE0201 E

200

160

125

1

4.800

GE0250 E

250

180

150

1

4.800

GE0315 E

315

200

160

1

5.000

GE0400 E

400

250

200

1

5.000

GE0500 E

500

400

250

1

11.500

GE0630 E

630

500

315

1

11.500

GE0800 E

800

630

400

1

11.900

GE1000 E

1000

1000

800

1

21.800

GE1250 E

1250

1000

900

1

23.600

GE1600 E

1600

1000

900

1

50.000

Order code

IEC conventional free air thermal current Ith AC21A (500V)

IEC rated operational current Ie AC23B AC23B (400V) (500V)

[A]

[A]

11

[A]

Qty Wt per pkg



[kg]

Selection of handles and accessories Types of handle to use per type are given below. Also refer to pages 11-19 and 11-21 for other accessories. Direct actuator

Door coupling

Black

Black

GEX61E

GEX61NC

GEX62NE

GEX62NC

GEX63NE

GEX63NC

GEX64NE

GEX64NC

Separately purchase the handle and shaft extension.

GE...ET4

GE0160 ET4 160

160

125

1

2.100

GE0200 ET4 200

160

125

1

2.200

GE0201 ET4 200

160

125

1

5.300

GE0250 ET4 250

180

150

1

5.300

GE0315 ET4 315

200

160

1

5,500

GE0400 ET4 400

250

200

1

5.500

GE0500 ET4 500

400

250

1

12.600

GE0630 ET4 630

500

315

1

12.600

GE0800 ET4 800

630

400

1

13.200

GE1000 ET4 1000

1000

800

1

24.300

GE1250 ET4 1250

1000

900

1

26.700

GE1600 ET4 1600

1000

900

1

55.000



Refer to the side table for the selection of the handle. A shaft insert is standard-supplied with all direct operating handles so no other shaft extension is required in this case.

General characteristics – IEC 160A to 1600A ratings – 4-pole types (3P+N) with early-make late-break neutral pole – Available versions: direct operating and door coupling – Screw fixing – Padlockable at 0 position with no extra accessory. Operational characteristics – IEC rated insulation voltage Ui: 1000V – Mechanical life: 30,000 cycles for GE0160 E/ET4 and GE0200 E/ET4 only; 10,000 cycles for other types. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

11-18

Add-on blocks/Accessories pages 11-19 to 21

Dimensions pages 11-43 to 47

Wiring diagrams page 11-51

Technical characteristics page 11-54 and 57

Switch disconnectors GE series 50A to 1600A Add-on blocks and accessories Auxiliary contacts Terminal covers Motorised unit

Order code

Characteristics

Qty Wt per pkg n° [kg]

Selection of add-on contacts and accessories Refer to the combinations given on pages 11-21 to 11-25 for a correct choice based on the switch disconnector type used.

1

General characteristics for auxiliary contacts IEC conventional free air thermal current Ith: 16A.

Auxiliary contacts. GEX10 11 1NO/1NC changeover/SPDT

0.032

Auxiliary contacts for switch disconnector types GE0050 F, GE0050 FT4, GE0125 F, GE0125 FT4, GE0160 N and GE0160 NT4. GEX10...

GEX10 11N 1NO/1NC changeover/SPDT

1

0.024

Auxiliary contacts for switch disconnector types GE0160 E, GE0200 E, GE0160 ET4, GE0200 ET4, GE1600 E and GE1600 ET4. GEX10 11M 1NO/1NC changeover/SPDT

1

0.016

1

0.040

Adapter kit for 35mm DIN fixing. GEX89 00

GEX89 00

For GE...P types only

Set of terminal covers consisting of pieces given below. See tables on pages 11-21 to 11-25 for the selection based on the switch disconnector type. Screw fixing. GEX81 01

1-piece set, transparent sheet covering four poles

1

0.048

GEX81 11

2-piece set, each covers two poles 1

0.080

GEX81 21

2-piece set, each covers two poles 1

0.140

GEX81 31

2-piece set, each covers two poles 1

0.170

GEX81 41

2-piece set, each covers two poles 1

0.440

GEX82 01

3-piece set, each covers one pole 1

0.090

GEX82 03

4-piece set, each covers one pole 1

0.120

GEX82 11

3-piece set, each covers one pole 1

0.120

GEX82 12

3-piece set, each covers one pole 1

0.120

GEX82 13

4-piece set, each covers one pole 1

0.160

GEX82 21

3-piece set, each covers one pole 1

0.240

GEX82 22

3-piece set, each covers one pole 1

0.240

GEX82 23

4-piece set, each covers one pole 1

0.320

GEX82 31

3-piece set, each covers one pole 1

0.340

GEX82 32

3-piece set, each covers one pole 1

0.340

GEX82 33

4-piece set, each covers one pole 1

0.440

GEX83 11

3-piece set, each covers one pole 1

0.120

GEX83 12

4-piece set, each covers one pole 1

0.160

GEX83 21

3-piece set, each covers one pole 1

0.260

GEX83 22

4-piece set, each covers one pole 1

0.340

GEX83 31

3-piece set, each covers one pole 1

0.360

GEX83 32

4-piece set, each covers one pole 1

0.460

General characteristics for motorised control unit – IEC rated auxiliary supply voltage: 230VAC/DC – 4 static outputs, 24VDC 120mA total – 4 inputs, contacts powered at 24VDC or 5VDC (500mA) for changeover control (pulsed or continuous) – RS485 Modbus serial port for control, monitoring, programming – Padlockable at 0 position – Programming by position inputs – 4-digit display for status-error indications. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

Snap-on fixing.

GEX8...

11

Motorised control unit for changeover switches. Rated auxiliary supply voltage 230VAC/DC. Complete with control handle, shaft extension and fixing elements. GEX69...

For the correct choice of auxiliary contacts, terminals covers and motorised unit for the switch disconnector, refer to tables on pages 11-21 to 11-25.

GEX69 1

For GE0201 E-GE0400 E and GE0201 ET4-GE0400 ET4

1

3.840

GEX69 2

For GE0500 E-GE0800 E and GE0500 ET4-GE0800 ET4

1

5.340

GEX69 3

For GE1000 E-GE1600 E and GE1000 ET4-GE1600 ET4

1

5.753

 

Suitable for all types except switch disconnectors GE0050 F, GE0050 FT4, GE0125 F, GE0125 FT4, GE0160 N, GE0160 NT4, GE0160 E, GE0200 E, GE0160 ET4, GE0200 ET4, GE1600 E and GE1600 ET4. Changeover contact/SPDT.

Dimensions pages 11-43 to 49

Wiring diagrams page 11-51

11-19

Switch disconnectors GE series 50A to 1600A Accessories Order code

Characteristics

Qty per pkg

Wt



[kg]

DIRECT OPERATING LEVER HANDLE, PADLOCKABLE . Rotating type with screw fixing on switch disconnector. Complete with shaft insert.

GEX...D-GEX...E

GEX6 2NE

GEX6 1D

95mm/3.7” black

1

0.340

GEX6 1E

50mm/2” black

1

0.052

GEX6 2D

105mm/4.1” black

1

0.268

GEX6 2NE

143mm/5.6” black

1

0.266

GEX6 3D

145mm/5.7” black

1

0.536

GEX6 3NE

360mm/14.2” black

1

0.424

GEX6 4D

360mm/14.2” black

1

0.612

GEX6 4NE

396mm/15.6” black

1

0.612

GEX6 5D

50mm/2” black

1

0.054

GEX6 6ND

115mm/4.5” black

1

0.216

GEX6 7ND

143mm/5.6” black

1

0.322

GEX6 8ND

396mm/15.6” black

1

0.328

DOOR COUPLING LEVER HANDLE, PADLOCKABLE . Red/yellow rotating type with screw fixing on door. Shaft extension to order separately.

11

GEX6 6N

Pistrol grip, 65mm/2.6” 7mm/0.3”. IEC IP66

1

0.140

GEX6 1N

94mm/3.7” 7mm/0.3”.

1

0.326

GEX61N-GEX61NB GEX61NC GEX61D

95mm (3.74”) GEX62D 105mm (4.1”)

143mm (5.6”)

GEX66ND-GEX66NB GEX66N GEX62NC-GEX62NE GEX67N-GEX67NB GEX67ND GEX63NC-GEX63NE

0.248

GEX6 7N

143mm/5.6” 14mm/0.6”. IEC IP65

1

0.302

245mm (9.6”)

2-hand GEX63D

GEX6 8N

396mm/15.6” 1 4mm/0.6”. IEC IP65

1

0.312

360mm (14.2”)

2-hand GEX64D

DOOR COUPLING LEVER HANDLE, PADLOCKABLE . Black rotating type with screw fixing on door. Shaft extension to order separately.

396mm (15.6”)

GAX66 B

Pistrol grip, 65mm/2.6” 7mm/0.3”. IEC IP66

1

0.075

GEX6 1NB

94mm/3.7” 7mm/0.3”. IEC IP65

1

0.334

GEX6 1NC

94mm/3.7” 7mm/0.3”. IEC IP65 143mm/5.6” 10mm/0.4”. IEC IP65

1

0.074

1

0.252

GEX6 3NC

176mm/6.9” 14mm/0.6”. IEC IP65

1

0.302

GEX6 4NC

396mm/15.6” 14mm/0.6”. IEC IP65

1

0.488

GEX6 6NB

115mm/4.5” 10mm/0.4”. IEC IP65

1

0.246

GEX6 7NB

143mm/5.6” 14mm/0.6”. IEC IP65 396mm/15.6” 14mm/0.6”. IEC IP65

1

0.298

1

0.310

150mm/5.9in; 7mm/0.3” 200mm/7.9in; 7mm/0.3”

1

0.090

GAX7 200A

1

0.112

GAX7 300A

300mm/11.8in; 7mm/0.3”

1

0.160

GEX7 162N

177mm/6.97”; 7mm/0.3”

1

0.056

GEX7 195N

195mm/7.7"; 14mm/0.6”

1

0.248

GAX7 150A

GEX7 227N

227mm/8.9”; 10mm/0.4”

1

0.154

GEX7 239N

239mm/9.4”; 14mm/0.6”

1

0.310

GEX7 250N

250mm/9.8”; 7mm/0.3”

1

0.084

GEX7 345N

345mm/13.6”; 14mm/0.6”

1

0.480

GEX7 375N

375mm/14.7”; 10mm/0.4”

1

0.274

GEX7 387N

387mm/15.2”; 7mm/0.3”

1

0.142

GEX7 536N

536mm/21.1”; 10mm/0.4”

1

0.408

GEX7 535N

535mm/21.06”; 14mm/0.6”

1

0.784

1 0.930 GEX7 485N 485mm/19.1”; 14mm/0.6”  See tables on pages 11-21 to 11-25 for the correct choice based on the switch disconnector type used.

 Use with GAX7...A extension types only.

11-20

94mm (3.7”)

1

SHAFT EXTENSION for door coupling lever handles.

For the correct choice of handle and shaft extension for the switch disconnector, refer to tables on pages 11-21 to 11-25.

GAX66-GAX66B 65mm (2.6”)

115mm/4.5” 10mm/0.4”. IEC IP65

GEX6 8NB

GEX7...

GEX61E-GEX65D 50mm (2”)

GEX6 6N

GEX6 2NC

GAX7...A

Type of handle

176mm (6.9”)

GEX6 8N

GEX6 7NB

Handle shape and length

115mm (4.5”)

GAX66 GAX66

Certifications and compliance Certifications obtained: EAC for all types; cULus to UL98 / CSA C22.2 n°4 for GAX66… and GAX7...A types (see pages 11-8 and 11-10 for cULus details). Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

Dimensions pages 11-30 to 49

2-hand GEX64NC-GEX64NE GEX68N-GEX68NB GEX68ND

Switch disconnectors GE series 50A to 1600A Summary table of combinations - Three and four-pole changeover switches Type

Order code

IEC Conventional free air thermal current Ith

IEC rated operational current Ie

AC21A (500V)

AC23B AC23B Black (400V) (500V)

Black

Red/Yellow

[A]

[A]

Order code

Order code

Order code

GEX61E

GEX61NC

––

[A]

Direct Door-coupling operating handles handle

Shaft extension for door-coupling handles (the last 3 digits of GEX code indicate length in mm/in)

Shaft section Order code

Auxiliary contacts 1NO/1NC

Motorised Terminal covers control unit for:

Max panel depth

Line 2

Load

Order code

Order code

Order code

[mm/in]

Order code

GEX7162N 7mm/

269/10.59”

GEX1011M ––

GEX7250N

342/13.36”

GEX8101  

GEX1011

GEX691

GEX8212 GEX8211 GEX8311

GEX692

GEX8222 GEX8221 GEX8321

GEX693

GEX8232 GEX8231 GEX8331

[mm/in]

Order code

Line 1

Changeover switches. Three poles. GE0160 E

160

160

125

GE0200 E

200

160

125

GE0201 E

200

160

125

GE0250 E

250

180

GE0315 E

315

GE0400 E

400

0.3”

GEX7387N

279/10.98”

150

GEX7375N

427/16.81”

200

160

GEX7536N

250

200

GE0500 E

500

400

250

630

500

315

GE0800 E

800

630

400

GE1000 E

1000

1000

800

GE1250 E

1250

1000

900

GE1600 E

1600

1000

900

GEX63NE GEX63NC

––

479/18.86”

GEX7227N 10mm/

GE0630 E

GEX62NE GEX62NC

––

0.4”

588/23.15”

GEX7195N

14mm/

257/10.12”

GEX7345N

0.6”

407/16.02”

GEX7535N GEX64NE GEX64NC

GEX8101

597/23.50”

––

280/11.02” 430/16.93” 620/24.41”

––

GEX7239N

14mm/

579/22.79”

GEX7485N

0.6”

825/32.48”

GEX1011M

GEX8141 ––

GEX8141

GEX1011M ––

GEX8101  

GEX8101

GEX1011

GEX691

GEX8213 GEX8213 GEX8312

GEX692

GEX8223 GEX8223 GEX8322

GEX693

GEX8233 GEX8233 GEX8332

Changeover switches. Four poles. GE0160 ET4 160

160

125

GE0200 ET4 200

160

125

GE0201 ET4 200

200

160

GE0250 ET4 250

200

GEX61E

GEX61NC

––

GEX7162N 7mm/

269/10.59”

GEX7250N

342/13.36”

0.3”

GEX7387N

279/10.98”

160

GEX7375N

427/16.81”

GEX7536N

250

200

GE0400 ET4 400

250

200

GE0500 ET4 500

400

315

GE0630 ET4 630

400

315

GE0800 ET4 800

630

400

GE1000 ET4 1000

1000

800

GE1250 ET4 1250

1000

900

GE1600 ET4 1600

1000

900

GEX63NE GEX63NC

––

479/18.86”

GEX7227N 10mm/

GE0315 ET4 315

GEX62NE GEX62NC

––

0.4”

588/23.15”

GEX7195N

14mm/

257/10.12”

GEX7345N

0.6”

407/16.02”

GEX7535N GEX64NE GEX64NC

597/23.50”

––

280/11.02” 430/16.93” 620/24.41”



––

GEX7239N

14mm/

579/22.79”

GEX7485N

0.6”

825/32.48”

GEX1011M

GEX8141 ––

GEX8141

GEX81 01 terminal cover protects the input of both Line 1 and Line 2.

Dimensions pages 11-43 to 45

Wiring diagrams page 11-51

Technical characteristics page 11-55

11-21

11

Switch disconnectors GE series 50A to 1600A Summary table of combinations - Three-pole switch disconnectors Three-pole type 

Order code

IEC Conventional free air thermal

IEC rated operational current Ie

Direct operating handle

Door-coupling handles

AC21A (500V)

AC23A AC23A (400V) (500V)

Black

Black

Red/Yellow

[A]

[A]

Order code

Order code

Order code

GEX65D

GAX66B GAX66

[A]

Shaft extensions for door-coupling handles (the last 3 digits of GEX code indicate length in mm/in)

Shaft section Order code

Auxiliary contacts 1NO/1NC (SPDT)

Type of fuse

Terminal covers for:

Max panel depth [mm/in]

Order code GEX1011

[mm/in]

Line

Load

Order code

Order code





GEX8101

GEX8101

GEX8111

GEX8111

GEX8121

GEX8121

GEX8131

GEX8131

GEX8141

GEX8141





Switch disconnectors.

11

GE0160 P 160

160

125

GAX7150A 7mm/

214/8.42”

GE0160

160

160

125

GAX7200A 0.3”

264/10.39”

GE0200

200

160

125

GAX7300A

364/14.33”

GE0250

250

160

125

GE0251

250

250

200

GE0315

315

315

250

GE0400

400

400

315

GE0500

500

500

400

GE0630

630

630

500

GE0800

800

630

500

GE1000

1000

800

800

GE1250

1250

800

800

GE1600

1600

1000

900

GEX66ND

GEX66NB GEX66N

GEX7227N

10mm/

267/10.51”

GEX7375N

0.4”

415/16.34”

GEX7536N GEX67ND

GEX67NB GEX67N

576/22.68”

GEX7195N

14mm/

251/9.88”

GEX7345N

0.6”

401/15.79”

GEX7535N GEX68ND

––

591/23.27”

GEX68NB GEX68N

267/10.51” 417/16.42” 607/23.90” GEX7239N

14mm/

399/15.71”

GEX7485N

0.6”

645/25.39”

Switch disconnectors with NFC fuse holder. GE0050 F

50

50

50

GE0125 F

125

125

125

GEX61D

GEX61NB GEX61N

GEX7162N

7mm/

192/7.56”

GEX7250N

0.3”

265/10.43”

GEX7387N

GEX1011N

14x51 22x58

402/15.83”

Switch disconnectors with NH fuse holder. GE0160 N

160

160

125

GEX61D

GEX61NB GEX61N

GEX7162N

7mm/

192/7.56”

GEX7250N

0.3”

265/10.43”

GEX7387N GE0161 N

160

160

160

GEX62D

GEX66NB GEX66N

250

250

250

GE0400 N

400

400

400

GE0630 N

630

630

630

GE0800 N

800

630

630

GEX63D

GEX67NB GEX67N

10mm/

302/11.89”

GEX7375N

0.4”

450/17.72”

GEX8201

GEX8201

GEX1011

0

GEX8211

GEX8212

GEX8221

GEX8222

3

GEX8231

GEX8232

A4

GEX8211

GEX8212

GEX8221

GEX8222

GEX8231

GEX8232

611/24.05”

GEX7195N

14mm/

271/10.67”

1

GEX7345N

0.6”

421/16.57”

2

GEX7535N GEX64D

00

402/15.83”

GEX7227N GEX7536N

GE0250 N

GEX1011N

611/24.05”

GEX68NB GEX68N

285/11.22” 435/17.12” 625/24.61”

Switch disconnectors with BS fuse holder. GE0160 B

160

160

160

GE0200 B

200

200

200

GE0250 B

250

250

250

GE0315 B

315

315

315

GE0400 B

400

400

400

GE0630 B

630

630

630

GE0800 B

800

630

630

GEX62D

GEX66NB GEX66N

GEX7227N

10mm/

302/11.89”

GEX7375N

0.4”

450/17.72”

GEX7536N GEX63D

GEX67NB GEX67N

B1-B2

611/24.05”

GEX7195N

14mm/

271/10.67”

B1-B2-B3

GEX7345N

0.6”

421/16.57”

B1-B2-B3-B4

GEX7535N GEX64D

GEX1011

GEX68NB GEX68N

611/24.05” 285/11.22”

C1-C2

435/17.12”

C1-C2-C3

625/24.61”    

The motorised control unit cannot be installed. Standard supplied with IP20 terminal protection warranted by wired equipment with only maximum conductor section of 95mm2. Suitable for mounting on 35mm DIN (IEC/EN 60715) rail, adapters kit is available on page 11-19. IEC 250A Ith; IEC 200A AC21A 500V. Standard supplied with IEC IP20 terminal protection warranted by wired equipment with only maximum conductor section of 35mm2 for GE0050 F and of 95mm2 for GE0125 F.

11-22

Dimensions pages 11-30 to 42

Wiring diagrams page 11-51

Technical characteristics pages 11-54 and 56

Switch disconnectors GE series 50A to 1600A Summary table of combinations - Four-pole switch disconnectors Four-pole type 

Order code

IEC conventional free air thermal

IEC rated operational current Ie

Direct operating handle

Door-coupling handles

AC21A (500V)

AC23A AC23A (400V) (500V)

Black

Black

Red/Yellow

[A]

[A]

Order code

Order code

Order code

GEX65D

GAX66B GAX66

[A]

Shaft extensions for door-coupling handles (the last 3 digits of GEX code indicate length in mm/in)

Shaft section Order code

Auxiliary contacts 1NO/1NC (SPDT)

Type of fuse

Max panel depth [mm/in]

Order code GEX1011

[mm/in]

Terminal covers for:

Line

Load

Order code

Order code





GEX8101

GEX8101

GEX8111

GEX8111

GEX8121

GEX8121

GEX8131

GEX8131

GEX8141

GEX8141





Switch disconnectors. GE0160 T4P

160

160

125

GAX7150A 7mm/

214/8.42”

GE0160 T4

160

160

125

GAX7200A 0.3”

264/10.39”

GE0200 T4

200

160

125

GAX7300A

364/14.33”

GE0250 T4

250

160

125

GE0251 T4

250

250

200

GE0315 T4

315

315

250

GE0400 T4

400

400

315

GE0500 T4

500

500

400

GE0630 T4

630

630

500

GE0800 T4

800

630

500

GE1000 T4

1000

800

800

GE1250 T4

1250

800

800

GE1600 T4

1600

1000

900

GEX66ND

GEX66NB GEX66N

GEX7227N

10mm/

267/10.51”

GEX7375N

0.4”

415/16.34”

GEX7536N GEX67ND

GEX67NB GEX67N

576/22.68”

GEX7195N

14mm/

251/9.88”

GEX7345N

0.6”

401/15.79”

GEX7535N GEX68ND

––

591/23.27”

GEX68NB GEX68N

267/10.51” 417/16.42” 607/23.90” GEX7239N

14mm/

399/15.71”

GEX7485N

0.6”

645/25.39”

Switch disconnectors with NFC fuse holder. GE0050 FT4

50

50

50

GE0125 FT4

125

125

125

GEX61D

GEX61NB GEX61N

GEX7162N

7mm/

192/7.56”

GEX7250N

0.3”

265/10.43”

GEX7387N

GEX1011N

14x51 22x58

402/15.83”

Switch disconnectors with NH fuse holder. GE0160 NT4

160

160

125

GEX61D

GEX61NB GEX61N

GEX7162N

7mm/

192/7.56”

GEX7250N

0.3”

265/10.43”

GEX7227N

10mm/

302/11.89”

GEX7375N

0.4”

450/17.72”

GEX7387N GE0161 NT4

160

160

160

GEX62D

GEX66NB GEX66N

250

250

250

GE0400 NT4

400

400

400

GE0630 NT4

630

630

630

GE0800 NT4

800

630

630

GEX63D

GEX67NB GEX67N

GEX8203

GEX8203

GEX1011

0

GEX8213

GEX8213

GEX8223

GEX8223

3

GEX8233

GEX8233

A4

GEX8213

GEX8213

GEX8223

GEX8223

GEX8233

GEX8233

611/24.05”

GEX7195N

14mm/

271/10.67”

1

GEX7345N

0.6”

421/16.57”

2

GEX7535N GEX64D

00

402/15.83”

GEX7536N GE0250 NT4

GEX1011N

611/24.05”

GEX68NB GEX68N

285/11.22” 435/17.12” 625/24.61”

Switch disconnectors with BS fuse holder. GE0160 BT4

160

160

160

GE0200 BT4

200

200

200

GE0250 BT4

250

250

250

GE0315 BT4

315

315

315

GE0400 BT4

400

400

400

GE0630 BT4

630

630

630

GE0800 BT4

800

630

630

GEX62D

GEX66NB GEX66N

GEX7227N

10mm/

302/11.89”

GEX7375N

0.4”

450/17.72”

GEX7536N GEX63D

GEX67NB GEX67N

GEX68NB GEX68N

B1-B2

611/24.05”

GEX7195N

14mm/

271/10.67”

B1-B2-B3

GEX7345N

0.6”

421/16.57”

B1-B2-B3-B4

GEX7535N GEX64D

GEX1011

611/24.05” 285/11.22”

C1-C2

435/17.12”

C1-C2-C3

625/24.61”    

The motorised control unit cannot be installed. Standard supplied with IP20 terminal protection warranted by wired equipment with only maximum conductor section of 95mm2. Suitable for mounting on 35mm DIN (IEC/EN 60715) rail, adapter kit is available on page 11-19. IEC 250A Ith; IEC 200A AC21A 500V. Standard supplied with IEC IP20 terminal protection warranted by wired equipment with only maximum conductor section of 35mm2 for GE0050 FT4 and of 95mm2 for GE0125 FT4.

Dimensions pages 11-42 to 30

Wiring diagrams page 11-51

Technical characteristics pages 11-54 and 56

11-23

11

Switch disconnectors For photovoltaic applications GA series Three-pole switch disconnectors

Order code

IEC conventional free air thermal current Ith

IEC rated operational current Ie DC21B

Qty Wt per pkg

Poles in series 800V 1000V 4p 6p 8p [A]

GA040 D

[A]

[A]

[A]



[kg]

Direct operating version, complete with black handle. For door-coupling version, separately purchase the handle and shaft extension; refer to pages 11-9 and 11-10.

GA080 D GA125 D

GA040 D

40

15

10

25

1

0.135

GA080 D

80

18

20

32

1

0.355

GA125 D

125

20

25

40

1

0.355



For other operational voltages, refer to technical characteristics on page 11-52 or 11-58.

NOTE: See UL/CSA ratings on page 11-58 and/or on the bottom of page 11-4.

General characteristics – IEC 40A to 125A ratings – Available versions: • Direct operating • Door coupling version. Use switch disconnector with direct actuator and separately purchase the handle and shaft extension for this version. See pages 11-9 and 11-10. – Screw or 35mm DIN (IEC/EN 60715) rail fixing – Padlockable in 0 position with no extra accessory. Operational characteristics – IEC rated insulation voltage Ui: 1000V – IEC rated impulse withstand Uimp: 8kV – Mechanical life: • 100,000 cycles for GA040 D and GAX42 040 D • 30,000 cycles for GA080 D, GAX42 080 D, GA125D and GAX42 125D. Transformation of direct operating version into door coupling type

Fourth pole add-on with simultaneous closing operation as corresponding GA...D switch poles.

Fourth pole add-on

GAX42 040D 40

––

––

––

1

0.040

GAX42 080D 80

––

––

––

1

0.110

GAX42 125D 125

––

––

––

1

0.110

GA040 D + GA040 D with GAX60 00 for 6 and 8 poles GA040 D GA080 D GA125 D (GAX64/64B)

( 5mm/0.2”)

GAX42...D

GAX7... (GAX63... only)

UTILISATION IN DC21B CATEGORY

11

IEC operational voltage Ue 600V 4-pole assembly

GA040 D GAX42 040D

GA080 D / GA125 D GAX42 080D / GAX42 125D

Maximum Current [A]

Assembly

Products to purchase and connect together

20

GA040D - 4 poles GA040D + GAX42040D

30

GA080D - 4 poles GA080D + GAX42080D

35

GA040D - 6 poles GA040D + GA040D + GAX6000

40

GA125D - 4 poles GA125D + GAX42125D

45

GA080D - 6 poles GA080D + GA080D + GAX6001

50

GA125D - 6 poles GA125D + GA125D + GAX6001

GAX63/63B GAX63 2/2B GAX64/64B GAX62/62B

GAX61/61B

IEC operational voltage Ue 800V

6-pole assembly GA080 D / GA125 D GA040 D

GAX60 00

GA040 D

GA080 D / GA125 D

GAX60 01

Maximum Current [A]

Assembly

Products to purchase and connect together

15

GA040D - 4 poles GA040D + GAX42040D

18

GA080D - 4 poles GA080D + GAX42080D

20

GA125D - 4 poles GA125D + GAX42125D

25

GA040D - 6 poles GA040D + GA040D + GAX6000

35

GA040D - 8 poles GA040D + GA040D + GAX6000 + GAX42040D + GAX42040D

40

GA125D - 6 poles GA125D + GA125D + GAX6001

50

GA080D - 8 poles GA080D + GA080D + GAX6001 + GAX42080D + GAX42080D

60

GA125D - 8 poles GA125D + GA125D + GAX6001 + GAX42125D + GAX42125D

GA040 D GAX42 040D

GAX60 00

GAX42 040D GA080 D / GA125 D

GAX42 080D / GAX42 125D

GAX7150A GAX7200A GAX7300A ( 7mm/0.3”)

GAX66 GAX66 B

10

GA040D - 6 poles GA040D + GA040D + GAX6000 GA080D - 6 poles GA080D + GA080D + GAX6001

25

GA040D - 8 poles GA040D + GA040D + GAX6000 + GAX42040D + GAX42040D

Strokes of GA…D types (switch and add-on pole)

32

GA080D - 8 poles GA080D + GA080D + GAX6001 + GAX42080D + GAX42080D

40

GA125D - 8 poles GA125D + GA125D + GAX6001 + GAX42125D + GAX42125D



GA080 D / GA125 D

GAX60 B

20

IEC operational voltage Ue 1000V

GA040 D

GA080 D GA125 D

Certifications and compliance Certifications obtained: EAC; UL Listed for USA and Canada (cULus - File E93602) as Manual Motor Controllers, to UL508/CSA C22.2 n° 14 for GA040 D and GAX42 040D; (cULus - File E328470) as Open Type Switches to UL98/CSA C22.2 n° 4 for GA080 D, GA125 D, GAX42 080D and GAX42 125D. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, UL98, CSA C22.2.

Maximum Current [A]

8-pole assembly

GA080 D + GA080 D / GA125 D + GA125 D with GAX60 01 for 6 and 8 poles

Assembly

Products to purchase and connect together

For other operational voltages, refer to technical characteristics on page 11-52 or 11-58.

Travel 0→1 0° GA040 D Main poles GAX420 40D Simultaneous fourth-pole add on

30°

60° 60° 60°

55°

GA080 D - GA125 D Main poles GAX42 080D - GAX42 125D Simultaneous fourth-pole add on

55° OFF

GAX60 01 GAX42 080D / GAX42 125D

11-24

Add-on blocks/Accessories pages 11-6 to 10

Dimensions pages 11-30 to 33

Wiring diagrams page 11-52

90°

Technical characteristics page 11-54 and 59

ON

Switch disconnectors For photovoltaic applications Four-pole switch disconnectors

Order code

Selection of handles and accessories Types of handle to use per type are given below. Also refer to pages 11-19 or 20 and at page bottom for other accessories.

IEC IEC rated Qty Wt per free air operational current Ie pkg thermal DC21B 220V 800V 1000V [A]

[A]

[A]

[A]



[kg]

Version for photovoltaic applications. Separately purchase the handle and shaft extension. GE0160 DT4

GE...DT4 - GE...DT4P

160

160

70

30

1

1.000

GE0160 DT4P 160

160

70

30

1

1.000

GE0125 DT4

125

125

125

100

1

1.900

GE0250 DT4

250

250

250

200

1

2.000

GE0315 DT4

315

315

280

250

1

4.000

GE0630 DT4

630

630

600

500

1

4.500

GE0800 DT4

800

800

630

630

1

4.500

GE1250 DT4

1250

1250 1000 850

1

8.900



Refer to the side table for the selection of the handle. A shaft insert is standard-supplied with all direct operating handles so no other shaft extension is required in this case.  Connection of four poles in series.  For other operational voltages, refer to technical characteristics on page 11-59.  Standard supplied with IEC IP20 terminal protection.

Direct operating Black

Door coupling Black

GEX65D

GAX66B

GAX66

GEX66ND

GEX66NB

GEX66N

GEX67ND

GEX67NB

GEX67N

GEX68ND

GEX68NB

GEX68N

Red/yellow

General characteristics – IEC 160A to 1250A ratings – Available versions: • Direct operating • Door coupling. Use switch disconnector with direct operation and separately purchase the handle and shaft extension. See page 11-20 and at page bottom. – Screw fixing: 35mm DIN rail mount adapter kit for GE0160 DT4P on p. 11-19 – Padlockable at 0 position with no extra accessory. Operational characteristics – IEC rated insulation voltage Ui: 1000V – Mechanical life: • 30,000 cycles for GE0160 DT4, GE0160 DT4P • 20,000 cycles for GE0125 DT4, GE0250 DT4, GE0315 DT4 • 10,000 cycles for GE0630 DT4, GE0800 DT4, GE1250 DT4.

11

Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.

Summary table of combinations Four-pole type 

Conventional free air thermal current Ith

Rated operational current Ie DC21B 

600V

800V

1000V

[A]

[A]

[A]

Order code

[A]

GE0160 DT4

160

160

70

30

GE0160 DT4P

160

160

70

30

Direct operating handle

Door-coupling handles

Shaft extension for door-coupling handles (the last 3 digits of GEX code indicate length in mm/in)

Black

Black

Red/Yellow

Order code

Order code

Order code

GEX65D

GAX66B

GAX66

Shaft section Order code

GE0125 DT4

125

125

125

100

GE0250 DT4

250

250

250

200

GE0315 DT4

315

315

280

250

GE0630 DT4

630

630

600

500

GE0800 DT4

800

800

630

630

GE1250 DT4

1250

1250

1000

850

GEX66ND

GEX67ND

GEX66NB

GEX67NB

GEX66N

GEX67N

GEX68NB

[mm/in]

Order code GEX1011

GAX7150A

7mm/

214/8.42”

GAX7200A

0.3”

236/9.29”

Terminal covers for:

Line

Load

Order code

Order code

GEX8101

GEX8101





GEX8111

GEX8111

GEX8121

GEX8121

GEX8131

GEX8131

336/13.22”

GEX7227N 10mm/

267/10.51”

GEX7375N

415/16.34”

0.4”

GEX7536N

576/22.68”

GEX7195N 14mm/

251/9.88”

GEX7345N

401/15.79”

0.8”

GEX7535N GEX68ND

Max panel depth

[mm/in]

GAX7300A

Auxiliary contacts 1NO/1NC (SPDT)

GEX68N

591/23.27” 267/10.51” 417/16.42” 607/23.90”

 

The motorised control unit cannot be installed. Connection of four poles in series. Standard supplied with IEC IP20 terminal protection warranted by wired equipment with only maximum conductor section of 95mm2. Suitable for mounting on 35mm DIN (IEC/EN 60715) rail, adapter kit is available on page 11-19.

Add-on blocks/Accessories pages 11-19 to 20

Dimensions pages 11-30 to 33

Wiring diagrams page 11-52

Technical characteristics page 11-54 and 59

11-25

Switch disconnectors Dimensions [mm (in)] GA SERIES - 16A TO 125A SWITCH DISCONNECTORS Direct operating version GA016 A - GA040 A GA063 SA GA040 D

22 (0.87”)

70 (2.75”) 43.9 (1.73”)

45 (1.77”) 41.9 (1.65”)

94 (3.70”)

32.5 (1.28”) 45 (1.77”)

78 (3.07”)

5 (0.20”)

70 (2.75”)

100 (3.94”)

70 (2.75”) 43.9 (1.73”)

5 (0.20”)

74 (2.91”)

36 (1.42”)

GA063 A - GA125 A GA080 D - GA125 D

14.2 (0.56”)

14.4 (0.57”)

38.2 (1.50”)

Door mount version GA016 C - GA040 C

GA063 C - GA125 C 19.9 (0.78”)

48.6 (1.91”)

20.8 (0.82”)

65 (2.56”)

78 (3.07”)

ADD-ON BLOCKS AND ACCESSORIES

70 (2.75”) 43.6 (1.72”)

48.6 (1.91”) 42.6 (1.68”)

12 (0.47”)

9 (0.35”)

78 (3.07”) 72.6 (2.86”)

5 (0.20”)

78 (3.07”)

41.6 (1.64”)

78 (3.07”) 72.6 (2.86”)

12 (0.47”)

Fourth pole GAX41 125A GAX42 063A...GAX42 125A GAX42 080D...GAX42 125D Neutral GAX32 A earth/ground GAX34 A terminals

32.5 (1.28”)

46.2 (1.82”) 43.6 (1.72”)

12 (0.47”)

Auxiliary contacts GAX10 11A GAX12 10EA

23 (0.90”)

70 (2.75”) 43.9 (1.73”)

5 (0.20”)

41.6 (1.64”)

Fourth pole GAX41 040A - GAX42 040A GAX41 063SA - GAX42 063SA GAX42 040D Neutral GAX31 A earth/ground GAX33 A terminals

Auxiliary contacts GAX10 11A GAX11 10EA

9 (0.35”)

For GA063 A-GA125 A, GA080 D, GA125 D

100 (3.94”)

For GA016 A-GA040 A, GA063 SA, GA040 D

GAX41 040A, GAX42 040A... GAX41 063SA, GAX42 063SA, GAX42 040D, GAX31 A, GAX33 A

GAX11 10EA GAX10 11A

GAX41 125A, GAX42 063A... GAX42 125A, GAX42 080D, GAX42 125D, GAX32 A, GAX34 A

GAX12 10EA GAX10 11A

Mechanical interlock GAX50 00 and mechanical coupling system GAX60 00 72 (2.83”)

Mechanical interlock GAX50 01 and mechanical coupling system GAX60 01

89 (3.50”)

140 (5.51”)

89 (3.50”) 27 (1.06”) 45 (1.77”)

100 (3.94”)

45 (1.77”)

78 (3.07”)

27 (1.06”)

GAX50 00 - GAX60 00 GAX50 01 - GAX60 01

GAX10 11C

43 (1.69”)

46.2 (1.82”)

8.5 (0.33”)

78 (3.07”)

72.6 (2.86”)

12 0.47”)

Fourth pole GAX41 125C GAX42 063C...GAX42 125C Neutral GAX32 C earth/ground GAX34 C terminals 23 (0.90”)

48.6 (1.91”)

100 (3.94”)

46.2 (1.82”)

8.5 0.33”)

For GA063 C - GA125 C Auxiliary contacts GAX10 11C

72.6 (2.86”)

Fourth pole GAX41 040C GAX42 040C Neutral GAX31 C earth/ground GAX33 C terminals

100 (3.94”) 41.6 (1.64”)

For GA016 C - GA040 C Auxiliary contacts GAX10 11C

78 (3.07”) 41.6 (1.64”)

11

70 (2.75”)

44.8 (1.76”) 55.5 (2.18”)

52.7 (2.07”)

100 (3.94”)

36 (1.42”)

GAX41 040C - GAX42 040C GAX31 C - GAX33 C GAX10 11C

GAX41 125C, GAX42 063C, GAX42 125C, GAX32 C, GAX34 C

11-26

Switch disconnectors Dimensions [mm (in)]

GAX62/62B

36 (1.42”) 1...4 (0.04”...0.16”) 23 22 (0.87”) (0.90”)

48 (1.89”) 36 (1.42”)

65 (2.56”)

Ø16 (0.63”) 28...32 (1.10”...1.26”) 36 (1.42”)

65 (2.56”)

1...4 (0.04”...0.16”) 35 (1.38”)

22 (0.87”)

65 (2.56”)

61.8 (2.43”)

65 (2.56”)

28...32 (1.10”...1.26”)

Ø16 (0.63”) 36 (1.42”) 48 (1.89”)

Rotary handles GAX61/61B

Ø3 (0.12”) Ø3 (0.12”)

GAX63 1B 34.3 (1.35”)

3.3 (0.13”)

2.5 ) Ø2 .88” (0

35 (1.38”) 1...4 (0.04”...0.16”)

3.3 (0.13”)

65 (2.56”) 37 (1.46”) Ø32.9 (1.29”)

65 (2.56”)

65 (2.56”) 37 (1.46”) Ø32.9 (1.29”)

65 (2.56”)

35 (1.38”) 1...4 (0.04”...0.16”)

24.3 (0.96”)

34.3 (1.35”)

2.5 ) Ø2 .88” (0

24.3 (0.96”)

GAX63/63B

Padlockable at ON (≤3 padlocks) per UNI 9490, UNI/EN 12485

GAX63 2/2B

GAX64/64B 35.5 (1.40”)

3.3 (0.13”)

1...4 (0.04”...0.16”) 35 (1.38”)

3.3 (0.13”)

2.5 ) Ø2 .88” (0

Ø22 (0.87”)

2.5 ) Ø2 .88” (0

24.3 (0.96”)

65 (2.56”)

Ø20 (0.79”)

65 (2.56”)

65 (2.56”)

65 (2.56”)

1...4 (0.04”...0.16”) 35 (1.38”)

24.3 (0.96”)

5 (0.20”)

11

GAX67 B 1...4 (0.04”...0.16”) 36 (1.42”)

2 Ø3 26”) (1.

48 (1.89”) 36 (1.42”)

1...4 (0.04”...0.16”) 35 (1.38”)

65 (2.56”)

75 (2.95”)

Ø66 (2.60”) Ø48 (1.89”)

65 (2.56”)

36 (1.42”)

46 (1.81”)

98 (3.86”) 60 (2.36”)

22 (0.87”)

Ø16 (0.63”) 36 (1.42”) 48 (1.89”)

GAX66/66B

Ø3 (0.12”)

Ø4.2 (0.16”)

Shaft extensions for door coupling handles GAX7... 5 (0.20”) 65 (2.56”)

Extension 5 (0.20”)

A

65 (2.56”)

A

Length [mm (in)]

GAX7055

GAX7090

65 (2.56”)

65 (2.56”)

GAX7070

GAX7150 GAX7200

GA016 A...GA040 A GA063 SA - GA040 D

GAX7...

GAX6... GAX7...

GAX7300

GAX6...

GA063 A...GA125 A GA080 D - GA125 D

GAX7400 GAX7500

GAX7... used with GAX50 00, GAX50 01 and GAX60 00

A1

A1 GAX50 00 GAX60 00

GAX50 01

20 (0.90”) GAX7...

GAX6...

GAX7...

20 ±1 (0.79” ±0.04”)

B

GAX6001 min. 10 (0.39”) 75 (2.95”)

Extension

100 (3.94”)

75 (2.95”)

Ø66 (2.60”)

GAX60B

GAX7...A

GAX7...A

GAX66...

GA063A...GA125A GA080D - GA125D

40 (1.57”) 19 (0.75”)

GAX7150A GAX7200A

19 (0.75”)

49 (1.93”)

A1 [mm (in)] maximum Used with Used with GAX60 00 GAX50 00/GAX50 01 Type of handle GAX62... GAX63... GAX64... GAX67 B 114 (4.49”) 119 (4.68”) 133 (5.24”) 114 (4.49”) 129 (5.08”) 134 (5.27”) 148 (5.83”) 129 (5.08”) 149 (5.87”) 154 (6.06”) 168 (6.61”) 149 (5.87”) 209 (8.23”) 214 (8.42”) 228 (8.98”) 209 (8.23”) 259 (10.20”) 264 (10.39”) 278 (10.94”) 259 (10.20”) 359 (14.13”) 364 (14.33) 378 (14.88”) 359 (14.13”) 459 (18.07”) 464 (18.27”) 468 (18.42”) 459 (18.07”) 559 (22.01”) 564 (22.20”) 578 (22.75”) 559 (22.01”)

20 ±1 (0.79” ±0.04”)

B1

min. 10 (0.39”)

GA063 A...GA125 A GA080 D - GA125 D

GAX67 B 97 (3.82”) 112 4.41”) 132 (5.20”) 192 (7.56”) 242 (9.53”) 342 (13.46”) 442 (17.40”) 542 (21.34”)

46 (1.81”)

46 (1.81”)

5 (0.20”)

A [mm (in)] maximum Type of handle GAX62... GAX63... GAX64... 97 102 116 (3.82”) (4.01”) (4.57”) 112 117 131 (4.41”) ((4.61”) (5.16”) 132 137 151 (5.20”) (5.39”) (5.94”) 192 197 211 (7.56”) (7.75”) (8.31”) 242 247 261 (9.53”) (9.72”) (10.27”) 342 347 361 (13.46”) (13.66”) (14.21”) 442 447 461 (17.40”) (17.60”) (18.15”) 542 547 561 (21.34”) (21.53”) (22.09”)

GAX7...A used with GAX60 01 and GAX66/66B handle

88 (3.46”) 73 (2.87”) 98 (3.86”) 60 (2.36”)

GAX67 B

GA063 A...GA125 A GA080 D - GA125 D

GAX7...A used with GAX60 B and GAX66/66B

Length [mm(in)]

GAX61... GAX7055 55 (2.16”) 116 (4.57”) GAX7070 70 (2.75”) 131 (5.16”) GAX7090 90 (3.54”) 151 (5.94”) GAX7150 150 (5.90”) 211 (8.31”) GAX7200 200 (7.87”) 261 (10.27”) GAX7300 300 (11.81”) 361 (14.21”) GAX7400 400 (15.75”) 461 (18.15”) GAX7500 500 (19.68”) 561(22.09”)

65 (2.56”)

100 (3.94”)

65 (2.56”)

78 (3.07”)

23 (0.90”) GA016 A...GA040 A GA063 SA - GA040 D

Extension

GAX61... 55 99 (2.16”) (3.90”) 70 114 (2.75”) (4.49”) 90 134 (3.54”) (5.27”) 150 194 (5.90”) (7.64”) 200 244 (7.87”) (9.61”) 300 344 (11.81”) (13.54”) 400 444 (15.75”) (17.48”) 500 544 (19.68”) (21.42”)

19 (0.75”)

GAX66...

GAX7300A

B B1 Length with GAX66/66B handle [mm(in)] [mm(in)] [mm(in)] 176 118...229 119...205 (6.93”) (4.64”...9.01”) (4.68”...8.07”) 226 118...279 119...255 (8.90”) (4.64”...10.99”) (4.68”...10.03”) 326 118...379 119...355 (12.83”) (4.64”...14.92”) (4.68”...13.98”)

1...4 (0.04”...0.16”)

1...4 (0.04”...0.16”)

11-27

Switch disconnectors Dimensions [mm (in)] Terminal covers GAX81 - GAX83

23 (0.90”)

GAX84

GAX82 20.7 (0.81”)

10 (0.39”)

70 (2.75”)

GAX84

23 (0.90”)

46 (1.81”)

8.6 (0.34”) 46 (1.81”)

70 (2.75”)

10 (0.39”)

GAX82

37.3 (1.47”)

12.7 (0.50”) 46 (1.81”)

37 (1.46”)

12 (0.47”)

GAX83 36 (1.42”)

10 (0.39”)

GAX81

46 (1.81”)

26.4 (1.04”)

36 (1.42”)

GAX82 - GAX84 3.6 (0.14”)

9.9 (0.39”)

12 (0.47”)

GAX83

26.4 (1.04”)

GAX81

80.1 (3.15”)

Fuse holder GAX39 1 - GAX39 1UL

75.2 (2.96”)

52.5 (2.07”)

ENCLOSED SWITCH DISCONNECTORS AND EMPTY ENCLOSURES GAZ016... - GAZ040... / GAZ016...UL - GAZ040...UL GAZ1... - GAZ1...UL

GAZ063 S... - GAZ100 C... / GAZ065S...UL - GAZ063C...UL GAZ2... - GAZ2...UL 121.5 (4.78”)

120 (4.72”) 97 (3.82”)

100 (3.94”) Ø4.5 (0.18”)

175 (6.89”)

98.5 (3.88”)

210 (8.27”)

159 (6.26”)

167.7 (6.60”)

11

23.3 (0.92”)

54 (2.12”)

Drilling for surface fixing 153.5 (6.04”)

Ø 4.5 (0.18”)

28 (1.10”)

120 (4.72”)

PG13.5 / M20 PG16 / M25 knockouts on top and bottom

52 (2.05”)

184 (7.24”)

PG16 / M25 PG29 / M32 knockouts on top and bottom

GAZ125... - GAZ080...UL - GAZ125...UL GAZ3... - GAZ3...UL 13 (0.51”)

220 (8.66”)

193 (7.60”) 170 (6.69”)

Drilling for surface fixing Ø 6.2 (0.24”)

11-28

238 (9.37”)

280 (11.02”)

178 (7.01”)

Switch disconnectors Dimensions [mm (in)] ENCLOSED CHANGEOVER SWITCHES GAZ025 ET6...GAZ063 SAET6 GAZ025 ET8...GAZ063 SAET8

Drilling for surface fixing

184.5 (7.26”)

175 (6.89”)

Ø 4.5 (0.18”)

184 (7.24”)

210 (8.27”)

153.5 (6.04”)

28 (1.10”)

52 (2.05”)

148.5 5.85”)

PG16 / M25 PG29 / M32 knockouts on top and bottom

11

GAZ080 ET6 - GAZ125 ET6 GAZ080 ET8 - GAZ125 ET8 208 (8.19”) 172 (6.77”)

13 (0.51”)

220 (8.66”)

280 ((11.02”)

Drilling for surface fixing Ø 6.2 (0.24”)

178 (7.01”)

238 (9.37”)

11-29

Switch disconnectors Dimensions [mm (in)] GE SERIES - 160A TO 1600A SWITCH DISCONNECTORS Door coupling version with handle GAX66 - GAX66 B

131 (5.16”)

Drilling

46 (1.81”)

Ø66 (2.60”)

36 (1.42”)

)

6”

1.2

2(

Ø3

Ø4

Ø4

.5 (

.5 (

0.1

8”

)

N

22.4 (0.88”)

85 (3.35”)

128 (5.04”) 110 (4.33”) 84.4 (3.32”)

) 8” 0.1

78.2 (3.08”) 14 (0.55”)

64 (2.52”) 18 (0.71”)

78.2 (3.08”) 14 (0.55”)

128 (5.04”) 110 (4.33”) 84.4 (3.32”)

53 (2.09”)

max. 364 (14.33”) 29 (1.14”) 77 (3.03”) 66 (2.60”) 3 (0.12”) GAX7 150A GAX7 200A GAX7 300A 7 (0.3”)

142 (5.59”)

36 (1.42”)

GE0160 T4 - GE0160 DT4

75 (2.95”)

GE0160

Ø4.2 (0.16”) GAX66... M8

M8

34 (1.34”)

34 (1.34”)

34 (1.34”)

34 (1.34”)

20 (0.79”)

 Not indicated on GE0160 DT4 type.

Direct operating version with handle GEX6 5D

With terminal cover and auxiliary contact 184 (7.24”)

2 (0.08”) GEX81 01 (line) 3 (0.12”) 22.4 (0.88”)

102 (4.01”)

68 (2.68”)

254 (10”)

50 (1.97”)

85 (3.35”)

GEX6 5D

11

1...4 (0.04...0.16”)

87 (3.42”)

34 (1.34”)

N

GEX10 11

GEX81 01 (load)

Ø (0. 4.5 18 ”)

Ø (0. 4.5 18 ”)

122 (4.80”) 74 (2.91”)

122 (4.80”) 74 (2.91”)

N

M8

34 (1.34”)

max. 364 (14.33”) 77 (3.03”) 29 (1.14”) 66 (2.60”) GAX7 150A GAX7 200A GAX7 300A 7 (0.3”)

76 (2.99”) 9.5 (0.37”)

34 (1.34”)

34 (1.34”)

19 (0.75”)

 Not indicated on GE0160 DTP4 type. Direct operating version with handle GEX6 5D

With auxiliary contact

102 (4.01”)

68 (2.68”)

N GEX6 5D 50 (1.97”) GEX10 11

11-30

36 (1.42”)

)

6”

1.2

2(

Ø3

Ø4.2 (0.16”) GAX66...

M8

34 (1.34”)

34 (1.34”)

Drilling 46 (1.81”)

75 (2.95”)

64 (2.52”) 18 (0.71”)

76 (2.99”) 9.5 (0.37”)

85 (3.35”)

53 (2.09”) 18 (0.71”)

Door coupling version with handle GAX66 - GAX66 B

140 (5.51”)

36 (1.42”)

GE0160 T4P - GE0160 DT4P 129 (5.08”)

Ø66 (2.60”)

GE0160 P

1...4 (0.04...0.16”)

Switch disconnectors Dimensions [mm (in)]

26 (1.02”)

78.2 (3.08”)

26 (1.02”)

5

. Ø4

)

8”

.1

(0

154 (6.06”) 130 (5.12”) 84.4 (3.32”)

64 (2.52”)

154 (6.06”) 130 (5.12”) 84.4 (3.32”)

53 (2.09”)

max. 364 (14.33”) 29 (1.14”) 77 (3.03”) 66 (2.60”) 3 22.4 (0.12”) (0.88”) GAX7 150A GAX7 200A GAX7 300A 7 (0.3”)

142 (5.59”)

N 5

. Ø4

)

8”

.1

(0

46 (1.81”) 36 (1.42”)

75 (2.95”)

11.8 (0.46”)

78.2 (3.08”)

Drilling

Ø66 (2.60”)

131 (5.16”)

Door coupling version with handle GAX66 - GAX66 B

36 (1.42”)

GE0200 T4 - GE0250 T4

85 (3.35”)

GE0200 - GE0250

)

6”

1.2

2(

Ø3

Ø4.2 (0.16”) GAX66...

M10

M10

42 (1.65”)

42 (1.65”)

42 (1.65”)

Direct operating version with handle GEX6 5D

19 (0.75”)

42 (1.65”)

1...4 (0.04”....0.16”)

With terminal cover and auxiliary contact 184 (7.24”)

68 (2.68”)

GEX81 01 (line)

2 (0.08”)

102 (4.01”)

3 22.4 (0.12”) (0.88”)

87 (3.42”)

42 (1.65”)

50 (1.97”)

85 (3.35”)

254 (10”)

GEX6 5D

N

11

GEX10 11

GEX81 01 (load)

GE0251 - GE0315 - GE0400

GE0125 DT4 - GE0250 DT4 - GE0315 DT4 GE0251 T4 - GE0315 T4 - GE0400 T4 217 (8.54”)

217 (8.54”) 100 (3.94”) 100 (3.94”)

Door coupling version with handle GEX66N - GEX66NB

100 (3.94”) 25 (0.98”)

117 (4.61”) 25 (0.98”)

117 (4.61”) 100 (3.94”)

20.2 (0.79”)

max. 486 (19.13”)

90 (3.54”) 4 (0.16”)

0

19 (0.75”)

22 (0.

Ø5 .5

Ø5 .5

(0.

22

”)

N

”)

0

114 (4.49”)

167 (6.57”) 143 (5.63”) 106 (4.17”)

167 (6.57”) 143 (5.63”) 106 (4.17”)

GEX66N GEX66NB

M1

0

50 (1.97”)

19 (0.75”) 50 (1.97”)

50 (1.97”)

M1

0

50 (1.97”)

GEX7277N GEX7375N GEX7536N 10 (0.4”)

27 1...4 (0.04”....0.16”) (1.06”) 45 (1.77”)

50 (1.97”)

 Not indicated on GE... DT4 type.  20mm (0.79”) and M8 for GE0125 DT4 type. Direct operating version with handle GEX66ND

Drilling

With terminal covers and auxiliary contact

GEX81 11 (line)

60 (2.36”)

200 (7.87”)

Ø5.5 (0.22”)

N

40 (1.57”)

GEX10 11 226 (8.90”) 106 (4.17”)

60 (2.36”)

28 (1.10”)

0

115 (4.53”)

34 (1.34”)

GEX81 11 (load)

11-31

Switch disconnectors Dimensions [mm (in)] GE0500 - GE0630 - GE0800

GE0500 T4 - GE0630 T4 - GE0800 T4 GE0630 DT4 - GE0800 DT4

275 (10.83”) 130 (5.12”) 140 (5.51”)

275 (10.83”)

145 (5.71”) C

130 (5.12”)

145 (5.71”)

Type

140 (5.51”)

C

A

GE0500 0

65 (2.56”)

Ø6 .5

Ø6 .5

(0 .2 5” )

(0 .2 5” )

B A 160 (6.30”)

B A 160 (6.30”)

N

M1

0 65 (2.56”)

65 (2.56”)

25 (0.98”) 65 (2.56”)

M1

0

 Not indicated on GE... DT4 type. For GE0500 - GE0630 - GE0800 - GE0500 T4 - GE0630 DT4 - GE0630 T4 - GE0800 DT4 - GE0800 T4 Direct operating version with handle GEX67ND Door coupling version with handle GEX67N - GEX67NB 30 (1.18”)

121 (4.76”) 5 (0.20”)

max 470 (18.50”)

Drilling 28 (1.10”)

190 (7.48”)

40 (1.57”)

60 (2.36”)

11

42 (1.65”)

143 (5.63”) GEX7195N GEX7345N GEX7535N 14 (0.6”)

With terminal covers and auxiliary contact GEX8121 (2 pcs/set) (line)

290 (11.42”)

0 GEX10 11

N

GEX8121 (2 pcs/set) (load)

11-32

65 (2.56”)

200 (7.87”)

1...4 (0.04”....0.16”)

C

190 220 25 (7.48”) (8.66”) (0.98”) 205 235 30 (8.07”) (9.25”) (1.18”) GE0800 205 235 30 (8.07”) (9.25”) (1.18”) GE0500 T4 190 220 25 (7.48”) (8.66”) (0.98”) GE0630 DT4 205 235 30 (8.07”) (9.25”) (1.18”) GE0630 T4 205 235 30 (8.07”) (9.25”) (1.18”) GE0800 DT4 205 235 30 (8.07”) (9.25”) (1.18”) GE0800 T4 205 235 30 (8.07”) (9.25”) (1.18”) GE0630

0

25 (0.98”) 65 (2.56”)

B

34 (1.34”)

Ø5.5 (0.22”)

Switch disconnectors Dimensions [mm (in)] GE1000 - GE1250

GE1000 T4 - GE1250 T4 GE1250 DT4 325 (12.79”)

325 (12.79”) 150 (5.90”)

150 (5.90”) 40 (1.57”)

175 (6.89”)

40 (1.57”)

140 (5.51”)

175 (6.89”) 140 (5.51”)

0

N

Ø6 .5

Ø6 .5

(0 .2 5” )

(0 .2 5” )

290 (11.42”) 250 (9.84”) 190 (7.48”)

290 (11.42”) 250 (9.84”) 190 (7.48”)

0

30 (1.18”) 75 (2.95”)

75 (2.95”)

M1

4

75 (2.95”)

75 (2.95”)

30 (1.18”) 75 (2.95”)

 Not indicated on GE... DT4 type. M1

4

For GE1000 - GE1250 - GE1000 T4 - GE1250 DT4 - GE1250 T4 Direct operating version with handle GEX68ND

11

396 (15.59”)

Door coupling version with handle GEX68N - GEX68NB 137 (5.39”) 8 (0.31”)

30 (1.18”)

max 470 (18.50”)

42 (1.65”)

Drilling

Ø5.5 (0.22”)

40 (1.57”)

190 (7.48”)

28 (1.10”)

34 (1.34”)

GEX7 195 GEX7 345 GEX7 535 14 (0.6”)

60 (2.36”) 1...4 (0.04”....0.16”)

With terminal covers and auxiliary contact GEX8131 (2 pcs/kit) (line)

75 (2,95”)

300 (11.81”)

340 (13.38”)

0 GEX10 11

N

GEX8131 (2 pcs/kit) (load)

11-33

Switch disconnectors Dimensions [mm (in)] GE1600

GE1600 T4 441 (17.36”)

441 (17.36”) 209 (8.23”)

Ø11 (0 .43”)

Ø (0. 16.2 64” )

40 (1.57”)

N

36 (1.42”) 100 (3.94”)

100 (3.94”)

Direct operating version with handle GEX68ND

441 (17.36”)

330 (12.99”)

381 (15”) 330 (12.99”) 100 (3.94”)

255 (10.04”)

O

255 (10.04”)

O

36 (1.42”) 100 (3.94”)

Door coupling version with handle GEX68N - GEX68NB max 483 (19.01”)

162 (6.38”)

200 (7.87”) 50 (1.97”)

10 (0.39”)

Drilling 28 (1.10”)

396 (15.59”)

40 (1.57”)

240 (9.45”)

60 (2.36”)

42 (1.65”)

60 (2.36”) 34 (1.34”)

GEX7 239N GEX7 485N 14 (0.6”)

With terminal covers and auxiliary contact

1...4 (0.04”...0.16”)

410 (16.14”) GEX81 31 (2 pcs/kit)

104 (4.09”)

(line)

255 (10.04”)

O

472 (18.58”)

11

60 (2.36”) 40 (1.57”)

60 (2.36”)

60 (2.36”)

Ø11 (0 .43”)

232 (9.13”)

Ø (0. 14.1 55” )

232 (9.13”)

Ø (0. 14.1 55” )

209 (8.23”)

GEX10 11

N

GEX81 31 (2 pcs/kit) (load)

11-34

Ø5.5 (0.22”)

Switch disconnectors Dimensions [mm (in)] GE SERIES - 50A TO 800A SWITCH DISCONNECTORS WITH FUSE HOLDER GE0050 FT4 with auxiliary contact

GE0050 F with auxiliary contact GEX10 11N

GEX10 11N

76 (2.99”) 130 (5.12”)

124 (4.88”)

104 (4.09”)

124 (4.88”)

31 (1.22”) 31 (1.22”)

GEX10 11N

5.4 (0.21”)

104 (4.09”)

5.4 (0.21”)

N

52 (2.05”)

31 (1.22”) 31 (1.22”) 31 (1.22”)

114 (4.49”)

28 (1.10”)

52 (2.05”) 121 (4.76”)

145 (5.71”)

GE0125 F with auxiliary contact 132 (5.20”) 5.4 (0.21”)

6 (0.24”)

GE0125 FT4 with auxiliary contact 169 (6.65”) 5.4 (0.21”)

GEX10 11N

GEX10 11N

150 (5.90”)

145 (5.71”) 104 (4.09”)

145 (5.71”) 104 (4.09”)

76 (2.99”)

GEX10 11N

N

11 37 (1.46”)

37 (1.46”)

37 (1.46”)

58 (2.28”)

37 (1.46”)

37 (1.46”)

28 (1.10”)

58 (2.28”)

6 (0.24”)

131 (5.16”)

For GE0050 F - GE0050 FT4 - GE125 F - GE125 FT4 Direct operating version with handle GEX61D 49 (1.93”)

184 (7.24”)

95 (3.74”)

GEX6 1D

34 (1.34”)

For GE0050 F - GE0050 FT4 - GE125 F - GE125 FT4 Door coupling version with handle GEX61N - GEX61NB Drilling

49 (1.93”) 26.5 (1.04”)

22.5 (0.88”)

28 (1.10”)

Ø5.5 (0.22”)

45 (1.77”)

13 (0.51”)

max 402 (15.83”) GEX7162N GEX7250N GEX7387N 7 (0.3”)

56 (2.20”)

GEX61N GEX61NB

34 (1.34”)

84.5 (3.33”)

95 (3.74”)

27 (1.06”)

max 281 (11.06”)

34 (1.34”)

GEX61N GEX61NB

11-35

Switch disconnectors Dimensions [mm (in)] GE0160 N with auxiliary contact

GE0160 NT4 with auxiliary contact

152 (5.98”) 5.4 (0.21”)

169 (6.65”) 5.4 (0.21”)

GEX10 11N

GEX10 11N

37 (1.46”)

37 (1.46”)

170 (6.69”)

170 (6.69”) 147 (5.79”) 104 (4.09”)

170 (6.69”) 147 (5.79”) 104 (4.09”)

76 (2.99”)

GEX10 11N

N

37 (1.46”)

37 (1.46”)

37 (1.46”)

58 (2.28”)

34 (1.34”) 131 (5.16”)

58 (2.28”)

For GE0160 N - GE0160 NT4 Direct operating version with handle GEX61D 184 (7.24”) GEX10 11N 49 (1.93”)

76 (2.99”)

GEX10 11N

170 (6.69”)

GEX6 1D

95 (3.74”)

11

34 (1.34”)

For GE0160 N - GE0160 NT4 Door coupling version with handle GEX6 1 - GEX6 1B

max 402 (15.83”)

Drilling

49 (1.93”) 26.5 (1.04”)

GEX7162N GEX7250N GEX7387N 7 (0.3”)

22.5 (0.88”)

Ø5.5 (0.22”)

28 (1.10”)

45 (1.77”)

GEX61N GEX61NB

56 (2.20”)

GEX61N GEX61NB

34 (1.34”)

27 (1.06”)

34 (1.34”)

95 (3.74”)

Terminal covers GEX82 01 for GE0160 N

Terminal covers GEX82 03 for GE0160 NT4

35 (1.38”)

35 (1.38”) GEX82 01 (line)

55 (1.38”) GEX82 03 (line)

GEX82 01 GEX82 03 (line)

299 (11.77”)

84.5 (3.33”)

N

GEX82 01 (load)

11-36

max. 271 (10.67”)

GEX82 03 (load)

GEX82 01 GEX82 03 (load)

Switch disconnectors Dimensions [mm (in)] GE0161 N with terminal covers and auxiliary contact

GE0161 NT4 with terminal covers and auxiliary contact

200 (7.87”)

239 (9.41”) 117.5 (4.62”)

121.5 (4.78”)

117.5 (4.62”)

GEX10 11

GEX10 11

C

18 (0.71”)

N

131 (5.16”) 150 (5.90”) 168 (6.61”) 192 (7.56”)

131 (5.16”) 150 (5.90”) 168 (6.61”) 192 (7.56”)

22 (0.87”)

M8

D

M8

D

45 (1.77”)

88 (3.46”)

25 (0.98”)

Ø5 (0.2 .5 2”)

25 (0.98”)

22 (0.87”)

C

42 (1.65”)

Ø5 (0.2 .5 2”)

82.5 (3.25”)

42 (1.65”)

45 (1.77”)

88 (3.46”)

18 (0.71”)

45 (1.77”)

11

For GE0161 N - GE0161 NT4 Direct operating version with handle GEX62D

Door coupling version with handle GEX66N - GEX66NB and terminal covers 39 (1.53”)

133 (4.13”)

3 (0.12”)

Drilling 45 (1.77”)

Ø5.5 (0.22”)

40 (1.57”)

28 (1.10”)

335 (13.19”) 142 (5.59”)

81 (3.19”)

157 (6.18”)

C

GEX66N GEX66NB

27 (1.06”)

34 (1.34”)

GEX7227N GEX7375N GEX7536N 10 (0.4”)

105 (4.13”)

D

165 (6.50”) 60 (2.36”)

TYPE GE0161 N GE0161 NT4

C (line) (N° of pcs/set) GEX82 11 (3) GEX82 13 (4)

max. 446 (17.56”)

D (load) (N° of pcs/set) GEX82 12 (3) GEX82 13 (4)

11-37

Switch disconnectors Dimensions [mm (in)] GE0250 N - GE0400 N - GE0315 B - GE0400 B with terminal covers and auxiliary contact

GE0250 NT4 - GE0400 NT4 - GE0315 BT4 - GE0400 BT4 with terminal covers and auxiliary contacts

274 (10.79”) 166 (6.53”)

C

30 (1.18”)

161 (6.34”) 200 (7.87”) 212 (8.34”) 242 (9.53”)

161 (6.34”) 200 (7.87”) 212 (8.34”) 242 (9.53”)

31 (1.22”)

10

10

22 (0.87”)

M

D

M

D

65 (2.56”)

59 (2.32”)

59 (2.32”)

115 (4.53”)

65 (2.56”)

22 (0.87”)

65 (2.56”)

For GE0250 N - GE0400 N - GE0250 NT4 - GE0400 NT4 Direct operating version with handle GEX63D

Door coupling version with handle GEX67N - GEX67NB and terminal covers

180 (7.09”)

51 (2.01”)

4 (0.16”)

C

Drilling

194 (7.64”)

60 (2.36”) 42 (1.65”)

28 (1.10”)

40 (1.57”)

410 (16.14”) 175 (6.89”)

81 (3.19”)

11

GEX10 11

Ø (0.2 7 7”)

30 (1.18”)

Ø (0.2 7 7”)

GEX10 11

115 (4.53”)

163 (6.42”)

31 (1.22”)

C

329 (12.95”)

163 (6.42”)

111 (4.37”)

GEX67N GEX67NB

34 (1.34”) 1...4 (0.04”... 0.16”)

245 (9.64”)

GEX7195N GEX7345N GEX7535N 14 (0.6”)

D

85 (3.35”)

TYPE GE0250 N GE0250 NT4 GE0400 N GE0400 NT4

11-38

C (line) D (load) (N° of pcs/set) (N° of pcs/set) GEX82 21 (3) GEX82 22 (3) GEX82 23 (4) GEX82 23 (4) GEX82 21 (3) GEX82 22 (3) GEX82 23 (4) GEX82 23 (4)

203 (7.99”)

max. 408 (16.06”)

Ø5.5 (0.22”)

Switch disconnectors Dimensions [mm (in)] GE0630 N with terminal covers and auxiliary contact

GE0630 NT4 with terminal covers and auxiliary contact

381 (15”)

426 (16.77”) 211 (8.31”)

215 (8.46”)

Ø9

C

212 (8.34”) 222 (8.74”) 227 (10.90”) 317 (12.48”)

N

30 (1.18”)

M1 2

212 (8.34”) 222 (8.74”) 227 (10.90”) 317 (12.48”) M1 2

D

40 (1.57”)

40 (1.57”)

40 (1.57”)

40 (1.57”)

D 85 (3.35”)

85 (3.35”)

163 (6.42”) 73 (2.87”)

73 (2.87”)

GE0800 N with terminal covers and auxiliary contact

30 (1.18”)

85 (3.35”)

163 (6.42”)

GE0800 NT4 with terminal covers and auxiliary contact

381 (15”)

426 (16.77”) 215 (8.46”) 10 (0.39”) 30 (1.18”)

GEX10 11 30 (1.18”) 50 10 10 (0.39”) (1.97”) (0.39”)

11

215 (8.46”)

211 (8.31”)

GEX10 11

30 (1.18”)

C

50 10 (0.39”) (1.97”)

212 (8.34”) 222 (8.74”) 322 (12.68”) 342 (13.46”) 10 (0.39”)

317(12.48”) 277 (10.90”) 40 (1.57”)

N

163 (6.42”)

D

85 (3.35”) 73 (2.87”)

73 (2.87”)

For GE0630 N - GE0630 NT4 - GE0800 N - GE0800 NT4 Direct operating version with handle GEX64D

30 (1.18”) 85 (3.35”)

30 (1.18”)

30 (1.18”)

M8

M8

D

30 (1.18”)

10 (0.39”)

212 (8.34”) 222 (8.74”) 322 (12.68”) 342 (13.46”)

40 (1.57”)

Ø9 (0.35”)

Ø9 (0.35”)

10 (0.39”)

10 (0.39”) 30 (1.18”)

166 (6.53”)

C

(0. 35 ”)

GEX10 11

(0. 35 ”)

GEX10 11

C

215 (8.46”)

Ø9

166 (6.53”)

85 (3.35”)

163 (6.42”)

Door coupling handle GEX68N - GEX68NB and terminal covers 56 (2.20”)

248 (9.76”)

6 (0.24”)

214 (8.42”)

C

Drilling 60 (2.36”)

28 (1.10”)

Ø5.5 (0.22”)

360 (14.17”)

40 (1.57”)

512 (20.16”) 232 (9.13”)

81 (3.19”)

42 (1.65”)

GEX68N GEX68NB

1...4 (0.04”... 0.16”)

TYPE GE0630 N - GE0630 B GE0630 NT4 - GE0630 BT4 GE0800 N - GE0800 B GE0800 NT4 - GE0800 BT4

C (line) (N° of pcs/set) GEX82 31 (3) GEX82 33 (4) GEX82 31 (3) GEX82 33 (4)

D (load) (N° of pcs/set) GEX82 32 (3) GEX82 33 (4) GEX82 32 (3) GEX82 33 (4)

D

90 (3.54”)

222 (8.74”)

34 (1.34”)

GEX7195N GEX7345N GEX7535N 14 (0.6”)

max 403 (15.89”)

11-39

Switch disconnectors Dimensions [mm (in)] GE0160 B - GE0200 B - GE0250 B with terminal covers and auxiliary contacts

GE0160 BT4 - GE0200 BT4 - GE0250 BT4 with terminal covers and auxiliary contacts

A

A

117.5 (4.62”)

117.5 (4.62”)

B

GEX10 11 ”)

25 (0.98”)

,5

18 (0.71”)

M8

D

131 (5.16”) 150 (5.90”) 168 (6.61”) 192 (7.56”)

22 (0.87”)

131 (5.16”) 150 (5.90”) 168 (6.61”) 192 (7.56”)

22 (0.87”)

Ø5.5

25 (0.98”)

GEX10 11

C

(0.22

C

Ø5.5 (0.22 ”)

B

M8

D

18 (0.71”)

42 (1.65”) 88 (3.46”)

11

45 (1.77”)

42 (1.65”)

42

88 (3.46”)

45 (1.77”)

45 (1.77”)

For GE0160 B - GE0200 B - GE0250 B - GE0160 BT4 - GE0200 BT4 - GE0350 BT4 Direct operating version with handle GEX62D

Door coupling version with handle GEX66N - GEX66NB and terminal covers 39 (1.53”)

133 (5.24”)

3 (0.12”)

Drilling

40 (1.57”)

28 (1.10”)

335 (13.19”) 142 (5.59”)

81 (3.19”)

157 (6.18”)

C

27 (1.06”) 45 (1.77”) GEX7277N GEX7375N GEX7536N 10 (0.4”)

105 (4.13”)

D

166 (6.63”) 60 (2.36”)

TYPE GE0160 B - GE0200 B GE0160 BT4 - GE0200 BT4 GE0250 B GE0250 BT4

11-40

A

B

200 (7.87”) 239 (9.41”) 200 (7.87”) 239 (9.41”)

82.5 (3.25”) 121.5 (4.78”) 82.5 (3.25”) 121.5 (4.78”)

C (line) (N° of pcs/set) GEX82 11 (3)

D (load) (N° of pcs/set) GEX82 12 (3)

GEX82 13 (4)

GEX82 13 (4)

GEX82 11 (3)

GEX82 12 (3)

GEX82 13 (4)

GEX82 13 (4)

max. 445 (17.52”)

34 (1.34”)

Ø5.5 (0.22”)

Switch disconnectors Dimensions [mm (in)]

163 (6.42”)

C

GEX10 11

22 (0.87”)

115 (4.53”)

GEX10 11 30 (1.18”)

161 (6.34”) 200 (7.87”) E F

161 (6.34”) 200 (7.87”) E F 10

M

D

163 (6.42”)

31 (1.22”)

30 (1.18”)

A

B

31 (1.22”)

C

A

Ø7 (0 .27” )

B

GE0315 BT4 - GE0400 BT4 with terminal covers and auxiliary contact

Ø7 (0 .27” )

GE0315 B - GE0400 B with terminal covers and auxiliary contact

22 (0.87”)

D

65 (2.56”)

59 (2.32”)

59 (2.32”)

115 (4.53”)

65 (2.56”)

65 (2.56”)

11

For GE0315 B - GE0400 B - GE0315 BT4 - GE0400 BT4 Direct operating version with handle GEX63D

Door coupling version with handle GEX67N - GEX67NB and terminal covers

180 (7.09”)

51 (2.01”)

G

C

194 (7.64”)

Drilling 60 (2.36”) 42 (1.65”)

Ø5.5 (0.22”)

40 (1.57”)

410 (16.14”) 175 (6.89”)

81 (3.19”)

28 (1.10”)

GEX67N GEX67NB 1...4 (0.04”...0.16”)

34 (1.34”)

245 (9.64”) GEX7195N GEX7345N GEX7535N 14 (0.6”)

D

202 (7.95”) 85 (3.35”)

TYPE GE0315 B GE0315 BT4 GE0400 B GE0400 BT4

A

B

274 (10.79”) 329 (12.95”) 274 (10.79”) 329 (12.95”)

111 (4.37”) 166 (6.53”) 111 (4.37”) 166 (6.53”)

C (line) (N° of pcs/set) GEX82 21 (3)

D (load) (N° of pcs/set) GEX82 22 (3)

GEX82 23 (4)

GEX82 23 (4)

GEX82 21 (3)

GEX82 22 (3)

GEX82 23 (4)

GEX82 23 (4)

E

F

G

212 (8.35”) 212 (8.35”) 216 (8.50”) 216 (8.50”)

242 (9.53”) 242 (9.53”) 246 (9.68”) 246 (9.68”)

4 (0.16”) 4 (0.16”) 5 (0.20”) 5 (0.20”)

max. 409 (16.1”)

11-41

Switch disconnectors Dimensions [mm (in)] GE0630 B with terminal covers and auxiliary contact

GE0630 BT4 with terminal covers and auxiliary contact

381 (15”)

426 (16.77”) 215 (8.64”)

211 (8.31”)

30 (1.18”)

163 (6.42”)

D

85 (3.35”)

73 (2.87”)

73 (2.87”)

GE0800 B with terminal covers and auxiliary contact

85 (3.35”)

GE0800 BT4 with terminal covers and auxiliary contact 426 (16.77”) 211 (8.31”)

215 (8.64”)

30 (1.18”)

C

50 10 (0.39”) (1.97”)

163 (6.42”)

212 (8.35”) 222 (8.74”) 322 (12.68”) 342 (13.46”)

85 (3.35”) 73 (2.87”)

73 (2.87”)

For GE0630 B - GE0630 BT4 - GE0800 B - GE0800 BT4 Direct operating version with handle GEX64D

30 (1.18”) 163 (6.42”)

85 (3.35”)

30 (1.18”)

40 (1.57”)

D

M8

30 (1.18”)

M8

30 (1.18”)

10 (0.39”)

212 (8.35”) 222 (8.74”) 322 (12.68”) 342 (13.46”)

Ø (0.3 9 5”)

10 (0.39”)

Ø (0.3 9 5”) 40 (1.57”)

D

10 (0.39”) 30 (1.18”)

10 (0.39”) 30 (1.18”)

10 50 (0.39”) (1.97”)

10 (0.39”)

215 (8.64”) GEX10 11

GEX10 11 30 (1.18”)

10 (0.39”)

166 (6.53”)

C

30 (1.18”)

163 (6.42”)

85 (3.35”)

381 (15”)

11

Ø9

212 (8.35”) 222 (8.74”) 277 (10.90”) 317 (12.48”)

212 (8.35”) 222 (8.74”) 277 (10.90”) 317 (12.48”)

M1 2

D

40 (1.57”)

40 (1.57”)

40 (1.57”)

40 (1.57”)

(0.3

(0.3

C

Ø9

C

5 ”)

GEX10 11

5 ”)

GEX10 11

215 (8.64”)

M1 2

166 (6.53”)

85 (3.35”)

Door coupling handle GEX68N - GEX68NB and terminal covers 56 (2.20”)

248 (9.76”)

6 (0.24”)

C

42 (1.65”) GEX68N GEX68NB

60 (2.36”)

360 (14.17”)

1...4 (0.04”... 0.16”)

TYPE GE0630 B - GE0800 B GE0630 BT4 - GE0800 BT4

C (line) (N° of pcs/set) GEX82 31 (3) GEX82 33 (4)

D (load) (N° of pcs/set) GEX82 32 (3) GEX82 33 (4)

D

90 (3.54”)

11-42

28 (1.10”) 40 (1.57”)

512 (20.16”) 232 (9.13”)

81 (3.19”)

214 (8.42”)

Drilling

222 (8.74”)

GEX7195N GEX7345N GEX7535N 14 (0.6”)

max. 403 (15.89”)

34 (1.34”)

Ø5.5 (0.22”)

Switch disconnectors Dimensions [mm (in)] GE SERIES - 160A TO 1600A CHANGEOVER SWITCHES GE0160 E

GE0160 ET4

181 (7.12”) 91 (3.58”) 14 (0.55”)

128 (5.04”) 110 (4.33”) 84.4 (3.32”)

128 (5.04”) 110 (4.33”) 84.4 (3.32”)

192 (7.56”) 91 (3.58”) 14 (0.55”)

64 (2.52”)

M8

18 (0.71”)

M8

53 (2.09”) 18 (0.71”)

N

Ø4

.5

34 (1.34”)

Ø4

.5

(0

.1

34 (1.34”)

8”

34 (1.34”)

)

34 (1.34”)

(0

.1

34 (1.34”)

8”

)

Direct operating version with handle GEX61E and auxiliary contacts 83 (3.27”)

171 (6.73”)

GEX10 11M

11

Door coupling version with handle GEX61NC

43.6 (1.72”)

145.6 (5.73”) 135 (5.31”) 3 (0.12”)

max. 333 (13.11”) 1...4 (0.04”...0.16”)

60 (2.36”)

Drilling

42 (1.65”)

Ø5.5 (0.22”)

40 (1.57”)

94 (3.70”)

28 (1.10”)

34 (1.34”)

44.8 (1.76”)

3 (0.12”)

GEX7162N GEX7250N GEX7387N 7 (0.3”)

GEX61NC

Terminal covers 3 (0.12”)

184 (7.24”)

249 (9.80”)

GEX81 01 (line 1 and line 2)

GEX81 01 (load)

11-43

Switch disconnectors Dimensions [mm (in)] GE0200 E

GE0200 ET4 181 (7.12”) 91 (3.58”) 26 (1.02”)

11.8 (0.46”)

193 (7.60”) 91 (3.58”)

65 (2.56”)

26 (1.02”)

154 (1.65”) 130 (5.12”) 84.4 (3.32”)

14 (0.55”)

154 (1.65”) 130 (5.12”) 84.4 (3.32”)

53 (2.09”)

14 (0.55”)

N

Ø4

.5

Ø4

.5

(0

.1

”)

)

42 (1.65”)

M

10

42 (1.65”)

42 (1.65”)

42 (1.65”)

42 (1.65”)

Direct operating version with handle GEX61E and auxiliary contacts 83 (3.27”)

171 (6.73”)

GEX10 11M

11

Door coupling version with handle GEX61NC

43.6 (1.72”)

145.6 (5.73”) 135 (5.31”) 3 (0.12”)

max. 333 (13.11”)

1...4 (0.04”...0.16”)

Drilling

60 (2.36”) 42 (1.65”)

Ø5.5 (0.22”)

94 (3.70”)

40 (1.57”)

28 (1.10”)

34 (1.34”)

44.8 (1.76”)

3 (0.12”)

GEX7162N GEX7250N GEX7387N 7 (0.3”)

GEX61NC

Terminal covers 3 (0.12”)

184 (7.24”)

249 (9.80”)

GEX81 01 (line 1 and line 2)

N

GEX81 01 (load)

11-44

(0

.1 8

8”

M

10

Switch disconnectors Dimensions [mm (in)] GE0201 E - GE0250 E - GE0315 E - GE0400 E GE0500 E - GE0630 E - GE0800 E with terminal covers and auxiliary contacts

GE0201 ET4 - GE0250 ET4 - GE0315 ET4 - GE0400 ET4 GE0500 ET4 - GE0630 ET4 - GE0800 ET4 with terminal covers and auxiliary contacts

A

A C

B

GEX10 11

GEX10 11

Y/Z

D

ØE

D

N

F G H

II

II

ØT

X

I

ØT

I

F G H

Y/Z

C

ØE

B

X

GEX10 11

K

GEX10 11

J

J

K

J

11

For GE0201 E - GE0250 E - GE0315 E - GE0400 E - GE0201 ET4 - GE0250 ET4 - GE0315 ET4 - GE0400 ET4 GE0500 E - GE0630 E - GE0800 E - GE0500 ET4 - GE0630 ET4 - GE0800 ET4 Direct operating version with handle

Door coupling version with handle N

U

P O

O

Z

W

V

Y

Drilling

42 (1.65”)

28 (1.10”)

Ø5.5 (0.22”)

L M

40 (1.57”)

60 (2.36”)

GEX62NC for GE0201 E...GE0400 E... GEX63NC for GE0500 E...GE0800 E...

S

34 (1.34”)

60 (2.36”)

1...4 (0.04”...0.16”)

X Q

TYPE GE0201 E GE0250 E GE0315 E GE0400 E GE0201 ET4 GE0250 ET4 GE0315 ET4 GE0400 ET4 GE0500 E GE0630 E GE0800 E GE0500 ET4 GE0630 ET4 GE0800 ET4

A

B

C

D

ØE

F

G

H

J

K

L

M

N

O

P

Q

R

R Max

S

ØT

U

V

235 119.5 115.5 25 5.5 157 192 216 45 88 357 170 42 3 67 151 437 143 M10 133 142 (9.25”) (4.70”) (4.55”) (0.98”) (0.22”) (6.18”) (7.56”) (8.50”) (1.77”) (3.46”) (14.05”) (6.69”) (1.65”) (0.12) (2.64”) (5.94”) (17.2”) (5.63”) (5.24”) (5.59”)

321 162 159 40 7 232 282 312 65 121 482 247 46 5 87 180 417 176 M12 186 171 (12.63”) (6.38”) (6.26”) (1.57”) (0.27”) (9.13”) (11.10”) (12.28”) (2.56”) (4.73”) (18.98”) (9.72”) (1.81”) (0.20”) (3.42”) (7.09”) (16.42”) (6.93”) M12 (7.32”) (6.73”)

Shaft extension W

GEX7227N GEX7375N GEX7536N 10 (0.6”)

GEX7195N GEX7345N GEX7535N 10 (0.6”)

X (line 1)

Terminal covers (N° of pcs/set) Y (line 2)

Z (load)

GEX82 12 (3)

GEX82 11 (3)

GEX83 12 (3)

GEX82 13 (4)

GEX82 13 (4)

GEX83 12 (4)

GEX82 22 (3)

GEX82 21 (3)

GEX83 21 (3)

GEX82 23 (4)

GEX82 23 (4)

GEX83 22 (4)

11-45

Switch disconnectors Dimensions [mm (in)] GE1000 E - GE1250 E with terminal covers and auxiliary contacts

GE1000 ET4 - GE1250 ET4 with terminal covers and auxiliary contacts

A

A C

B

GEX10 11

GEX10 11

Y/Z

D

ØE

D

N

F G H

II

II

X

GEX10 11

K

GEX10 11

J

J

K

J

For GE1000 E - GE1250 E - GE1000 ET4 - GE1250 ET4 Direct operating version with handle GEX64NE

Direct operating version with handle GEX64NC N

U

P O

O

Z

W

V

Y

42 (1.65”)

Drilling Ø5.5 (0.22”)

28 (1.10”)

L M

40 (1.57”)

60 (2.36”)

11

ØT

X

I

ØT

I

F G H

Y/Z

C

ØE

B

396 (15,59”)

34 (1.34”)

60 (2.36”)

1...4 (0.04”...0.16”)

X Q

TYPE GE1000 E GE1250 E GE1000 ET4 GE1250 ET4

11-46

A

B

C

D

ØE

F

G

H

J

K

L

M

N

O

P

Q

R Max

T

R

ØT

U

V

424 210 214 50 9 295 375 419 85 163 595 315 57 6 88 208 412 360 M14 248 199 (12.69”) (2.68”) (8.43”) (1.97”) (0.35”) (11.61”) (14.63”) (16.5”) (3.35”) (6.42”) (23.43”) (12.4”) (2.24”) (0.24”) (3.46”) (8.19”) (16.22”) (14.17”) (9.76”) (7.83”)

Shaft extension W GEX7195N GEX7345N GEX7535N 14 (0.6”)

X (line 1)

Terminal covers (N° of pcs/set) Y (line 2)

Z (load)

GEX82 32 (3)

GEX82 31 (3)

GEX83 31 (3)

GEX82 33 (4)

GEX82 33 (4)

GEX83 32 (4)

Switch disconnectors Dimensions [mm (in)] GE1600 ET4 250 (9.84”)

200 (7.87”)

330 (12.99”)

381 (15”) 330 (12.99”)

255 (10.04”)

441 (17.36”)

40 (2.75”)

Ø (0. 16.2 64 ”)

60 (2.36”)

N (0. Ø13 51 ”)

(0. Ø13 51 ”)

330 (12.99”)

40 (2.75”)

60 (2.36”)

250 (9.84”)

209 (8.23”) 60 (2.36”)

Ø (0. 14.1 55 ”)

200 (7.87”)

Ø (0. 14.1 55 ”)

209 (8.23”)

36 (1.42”)

100 (3.94”)

441 (17.36”)

GE1600 E

36 (1.42”)

100 (3.94”)

100 (3.94”)

100 (3.94”)

551 (21.69”)

100 (3.94”) 551 (21.69”)

Direct operating version with handle GEX64NE

Door coupling version with handle GEX64NC

200 (7.87”) 100 (3.94”)

10 (0.39”) max. 484 (19.05”)

Drilling 28 (1.10”)

Ø5.5 (0.22”)

40 (1.57”)

310 (12.20”)

350 (13.78”)

42 (1.65”)

34 (1.34”) 60 (2.36”) 1...4 (0.04”...0.16”)

396 (15.59”)

120 (4.72”)

10 (0.39”) 342 (13.46”)

Auxiliary contacts

GEX7239N GEX7485N 14 (0.6”)

GEX10 11M

GEX81 41 (line 1 - 2 pcs/set)

472 (18.58”)

Terminal covers

N

GEX81 41 (load - 2 pcs/set)

11-47

11

Switch disconnectors Dimensions [mm (in)]

21.7 (0.85”)

16 (0.63”)

39.7 (1.56”)

GEX10 11N 24 (0.94”)

GE SERIES - ADD-ON BLOCKS AND ACCESSORIES Auxiliary contacts GEX10 11 - GEX10 11M

10.3 (0.40”)

48.5 (1.91”)

25.2 (0.99”)

16 (0.63”) 21.7 (0.85”)

35mm DIN rail adapter kit GEX89 00 For GE0160 P

93.9 (3.70”) 86.5 (3.40”)

For GE0160 T4P - GE0160 DT4P

12.5 (0.49”)

Motorised control unit GEX69 1 - GEX69 2 - GEX69 3

112 (4.41”)

H

11

98 (3.86”) 10 (0.39”)

B

Ø5

.5

(0

.2

2” )

16 (0.63”)

A

57.5 (2.26”)

F

G

A

®

C E

D

Type

A

B

C

D

E

F

G

H

GEX69 1

52.5 (2.07”)

133 (5.24”)

117 (4.61”)

150 (5.90”)

150 (5.90”)

237 (9.33”)

380 (14.96”)

245 (9.64”)

GEX69 2

88.5 (3.48”)

167 (6.57”)

153 (6.02”)

184 (7.24”)

172 (6.77”)

312 (12.28”)

455 (17.91”)

360 (14.17”)

GEX69 3

88.5 (3.48”)

167 (6.57”)

153 (6.02”)

184 (7.24”)

172 (6.77”)

312 (12.28”)

455 (17.91”)

360 (14.17”)

11-48

Switch disconnectors Dimensions [mm (in)]

I

K

GEX69 1 for GE0201 E - GE0201 ET4 - GE0250 E - GE0250 ET4 - GE0315 E - GE0315 ET4 - GE0400 E - GE0400 ET4 GEX69 2 for GE0500 E - GE0500 ET4 - GE0630 E - GE0630 ET4 - GE0800 E - GE0800 ET4 GEX69 3 for GE1000 E - GE1000 ET4 - GE1250 E - GE1250 ET4

H J

L

Type

H

I

J

K

GEX69 1

245 (9.64”)

310 (12.20”)

235 (9.25”)

383 (15.08”)

L 254 (10”)

GEX69 2

360 (14.17”)

339 (13.35”)

321 (12.64”)

468 (18.42”)

283 (11.14”)

GEX69 3

360 (14.17”)

367 (14.45”)

424 (16.69”)

522 (20.55”)

311 (12.24”)

GEX69 3 mounted on GE1600 E - GE1600 ET4

532 (20.94”)

11

447 (17.60”)

459 (18.07”)

503 (19.80”)

552 (21.73”)

360 (14.17”)

11-49

Switch disconnectors Wiring diagrams GA SERIES - 16A TO 125A SWITCH DISCONNECTORS

LINE L2

L3

Line 7 L4

Line 7 L4

8 T4

L1

Fourth pole add on GAX41... GAX42...

8 T4

Three-pole disconnectors GA016... - GA125A/C GAZ016... - GAZ125/B GAZ016UL... - GAZ125UL

Four-pole disconnectors GAZ160 T4... - GAZ125 T4 GAZ016 T4UL... - GAZ125 T4UL

L4 (N)

LINE L2 L1

L3

N

T3

T4(N)

7 L4

T2 LOAD

7 L4

T1

8 T4 Load

8 T4 Load

T1 T2 LOAD

T3

ADD-ON BLOCKS AND ACCESSORIES

57

13

21

68

14

22

Neutral terminal GAX31... - GAX32...

Earth terminal GAX33... - GAX34... PE

N

N

GAX11... - GAX12...

67 58

11 ENCLOSED CHANGEOVER SWITCHES Three-pole GAZ...ET6 L1

T1

LINE 1 L2 L3

T2 T3 LOAD

11-50

L1

T1

Four-pole GAZ...ET8 LINE 2 L2 L3

T2 T3 LOAD

Fuse holder GAX39 1 L1

L2

L3

T1

T2

T3

PE

Auxiliary contacts GAX10...

L4

T4

LINE 1 L2 L1

T1 T2 LOAD

L3

L1

T3

T1

LINE 2 L3 L2

T2 T3 LOAD

L4

T4

Switch disconnectors Wiring diagrams GE SERIES - 50A TO 1600A SWITCH DISCONNECTORS Three-pole disconnectors GE0160 - GE1600 GE0160 P

L1

T1

LINE L2

T2 LOAD

Three-pole disconnectors with fuse holders GE0050 F - GE0125 F GE0160 N - GE0800 N GE0160 B - GE0800 B

L3

L1

T3

T1

LINE L2

T2 LOAD

Four-pole disconnectors GE0160 T4 - GE1600 T4 GE0160 T4P

L3

L4 (N)

T3

T4(N)

LINE L2 L1

T1 T2 LOAD

Four-pole disconnectors with fuse holders GE0050 FT4 - GE0125 FT4 GE0160 NT4 - GE0800 NT4 GE0160 BT4 - GE0800 BT4

L3

L4 (N)

T3

T4(N)

LINE L2 L1

T1 T2 LOAD

L3

T3

160A TO 1600A CHANGEOVER SWITCHES Three-pole switches GE0160 E - GE0200 E LINE 1 L2 L3 L1

LINE 2 L2 L3 L1

T1

T1

T2 T3 LOAD

Four-pole switches GE0160 ET4 - GE0200 ET4

GE0201 E - GE1600 E LINE 1 L2 L1

L3

T1

T3

LOAD

L4

T4

T2 T3 LOAD T2 LINE 2

LINE 1 L2 L1

T1 T2 LOAD

GE0201 ET4 - GE1600 ET4

L3

L1

T3

T1

LINE 2 L3 L2

T2 T3 LOAD

L4

L4 (N)

LINE 1 L2 L1

L3

LOAD

T4

T4(N)

T1 T2 LINE 2

T3

11

ADD-ON BLOCKS AND ACCESSORIES Auxiliary contacts GEX10 11 - GEX10 11M - GEX10 11N

Motorised control unit GEX69 1 - GEX69 2 - GEX69 3 L N

3

230VAC/DC

2

B A 3 4 5 6 7 8 9 10 IN

Signals

Error 0 1 2

RS485

1

+24VDC +5VDC Closing pes. II Closing pes. I Open all poles

1 2

11 12 13 14 15 OUT

11-51

Switch disconnectors Wiring diagrams FOR PHOTOVOLTAIC APPLICATIONS GA SERIES - with GA...D types One-line control 2 poles in series LINE

+

3 poles in series LINE

+



L1



LINE

+

L2

L1

L2

4 poles in series L3



L2

L1

L3

L4

 The positive pole of the load is connected to the fourth pole of the

switch disconnector on the right. If it is to be connected on the left, wiring needs to change accordingly.

T1

+

T1

T2

LOAD

T2

T3

T1

T2



LOAD

T4

+

+

LOAD

6 poles in series

8 poles in series LINE

+

+





LINE

L1

L2

L3

L1

L2

L3

L4

L1

L2

L3

L1

L2

L3

L4

T1

T2

T3

T1

T2

T3

T4

T1

T2

T3

T1

T2

T3

T4

+



LOAD

+

Two-line control 2+2 poles in series

11

T3





LINE

+

L1

T1

+

LOAD



LINE



L2

L3

T2

T3





LOAD

+ L4

T4

+

 The positive pole of the load is connected to the fourth pole of the

switch disconnector on the right. If it is to be connected on the left, wiring needs to change accordingly.

GE SERIES - with GE...DT4 and GE0160 DT4P types One-line control 4 poles in series

4 (2+2) poles in series

LINE

+ L1

L2

T1

T2

+

11-52



LINE

+

L3

L4

L1

T3

T4

T1

LOAD



+



L2

L3

L4

T2

T3

T4

LOAD



LOAD



Switch disconnectors Technical characteristics GA series 16A to 125A TYPE

3-pole 4th-pole

GA016...

GA025...

GA032...

GA040...

GA063 SA

GA063...

GA080...

GA100...

GA125...

GAX42 040... GAX42 040... GAX42 040... GAX42 040... GAX42 063SA GAX42 063... GAX42 080... GAX42 100... GAX42 125...

CONTACT CHARACTERISTICS IEC conventional free air thernal current Ith (40°C)

A

16

25

32

40

63

IEC rated insulation voltage Ui

V

1000

IEC rated impulse withstand voltage Uimp

kV

8

63

80

100

125

IEC rated operational current Ie AC21A

AC22A

AC23A

400V

A

16

25

32

40

63

63

80

100

125

500V

A

16

25

32

40

63

63

80

100

125

690V

A

16

25

32

40

63

63

80

100

125

400V

A

16

25

32

40

45

63

80

100

125

500V

A

16

25

32

40

45

63

80

100

125

690V

A

16

25

32

40

45

63

80

100

125

400V

A

16

25

32

40

45

63

80

100

125

500V

A

16

25

25

25

25

63

63

80

100

690V

A

16

25

25

25

25

47

47

47

47

400V

kW

7.5

11

15

18.5

22

30

45

55

55

690V

kW

11

22

22

22

22

45

45

45

45

kvar

7.5

10

12.5

15

15

25

30

40

50

IEC rated operational power AC23A IEC reactive power for capacitor control 400V IEC protection against short-circuit Rated short-time withstand current (1s) Icw

A rms

Rated conditional short-circuit current

kA rms

With fuse class gG

A

IEC making capacity (AC23A 400V)

800

11

50 16

25

32

A

IEC breaking capacity (AC23A 400V)

2500

40

400

63

63

80

450

A

320

360

1000

Mechanical life

cycles

100,000

100,000

30,000

Electrical life (IEC AC21A)

cycles

100,000

100

125

1250

15,000

30,000

UL/CSA general use at 600V

A

16

25

32

40

50

60

100

100

100

UL/CSA short-circuit rating at 600V

kA

5

5

5

5

5

10

10

10

10

Type/A

RK5/20

RK5/30

RK5/35

RK5/45

RK5/45

–/100

–/100

–/100

–/100

UL/CSA fuse class/max rating at 600V 120V

HP

1

11/2

2

2

3

3

3

5

71/2

Single phase

240V

HP

2

3

5

5

71/2

71/2

10

10

10

Three phase

200-208V

HP

5

71/2

10

10

10

20

25

30

25

240V

HP

5

71/2

10

15

15

20

30

30

30

480V

HP

10

15

20

20

30

40

40

50

50

600V

HP

10

20

20

25

30

40

40

60

40

UL/CSA HP ratings

Type B

Terminals

Lug clamp

A mm

5.6 (0.22”)

12.4 (0.49”)

B mm

6.5 (0.26”)

10.4 (0.41”)

Screw

M4

M8

Tool

Phillips 2

Metric Allen key 4

A

Tightening torque min...max

Nm

1.8...2

5...6

lbin

16...18

45...54

Conductor section min...max (flexible/stranded)

mm2

0.75...16

4...50

AWG

18...6

12...1

AMBIENT CONDITIONS Temperature

Operating

°C

-25…+55

Storage

°C

-40…+70

Maximum altitude

m

Mounting position Normal Admissible Fixing

3000 Vertical Any By screw or on 35mm DIN rail (IEC/EN 60715)

 IEC/EN 60947-1 designation: Pillar terminal.

11-53

Switch disconnectors Technical characteristics GE series 160A to 1600A MOUNTING POSITION The performances, given in this catalogue, have been established with GE series switch disconnectors mounted on a vertical place with line terminals facing upwards and load terminals facing downwards. All GE series switch disconnectors can be mounted as illustrated in the following figures without any derating except for position A. It is not recommended to mount switch disconnectors with the neutral pole facing downwards. SWITCH DISCONNECTORS

N

0

0 0

N

N

0

N

Pos. A

II

N

II

I

N

I

N

N

I

II

II

11

I

CHANGEOVER SWITCHES

Pos. A MOTORISED CHANGEOVER SWITCHES

Pos. A

Pos. A  Special assembly, consult Customer Service for details; contact details on inside front cover.

11-54

Switch disconnectors Technical characteristics GE series 160A to 1600A - Three and four-pole switch disconnectors TYPE

3-pole 4-pole 

GE0160P GE0160

GE0200

GE0250

GE0251

GE0315

GE0400

GE0500

GE0630

GE0800

GE1000

GE1250

GE1600

GE0160 T4P GE0160 T4 GE0200 T4 GE0250 T4 GE0251 T4 GE0315 T4 GE0400 T4 GE0500 T4 GE0630 T4 GE0800 T4 GE1000 T4 GE1250 T4 GE1600 T4

CONTACT CHARACTERISTICS IEC conventional free air current Ith (40°C)

A

IEC rated insulation voltage Ui

V

IEC rated impulse withstand voltage Uimp

kV

160

200

250

250

315

400

500

630

800

1000

1250

1600

1000 8

12

IEC rated operational current Ie AC21A

AC22A

AC23A

400V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

500V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

690V

A

160

180

180

200

250

250

500

630

800

1000

1000

1600

400V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

500V

A

160

200

200

250

315

400

500

630

800

1000

1000

1250

690V

A

125

160

160

160

200

200

400

500

500

630

630

1000

400V

A

160

160

160

250

315

400

500

630

800

800

800

1000

500V

A

125

125

125

200

250

315

400

500

500

800

800

900

690V

A

80

80

80

160

160

160

250

315

315

500

500

630

kvar

72

72

72

112

142

180

225

284

284

360

360

450

IEC reactive power for capacitor control 400V sine  = 0.65 IEC rated operational power AC23A

400V

kW

90

90

90

138

174

220

220

349

443

443

443

554

690V

kW

75

75

75

153

153

153

239

300

300

478

478

600

Protection against short-circuit IEC rated short-time withstand current (1s) Icw

kA rms

IEC rated conditional short-circuit current

kA rms

With fuse class gG IEC making capacity (AC23A 400V) IEC breaking capacity (AC23A 400V)

A

7

12 100

160

A

200

250

1600

2500 2000

A

1280

Mechanical life

cycles

30,000

Electrical life (AC23A 400V)

cycles

315

400

500

3150

4000

5000

6300

A mm A

Tightening torque

800

2520

3200

4000

5000

25

35

72

72

1000

1250

2x800

8000

10000

6400

8000

10,000

1,000

500 Terminal for lugs or bars

18

B mm Screw

630

20,000

Type

B

Terminals

16

26

25

3

25

30

4

M8

5

M10

M10

40

60

8

10

M14

M14

Nm

13

18

24

45

55

lbft

10

13

18

33

40

Maximum conductor section

mm2

95

120

Maximum bar size (thickness-width)

mm

5-25

5-30

185

240

2x185

2x240

2x300

––

6-40

2x 5-40

2x 10-50

2x 7-80

7-25

AMBIENT CONDITIONS Temperature

Operating

°C

-25…+55

Storage

°C

-40…+70

Maximum altitude Mounting position

m Normal Admissible

Fixing

3000 Vertical Any Screw

 With protection fuse to limit current peak and let-through energy.  Not suitable with GE0160 P and GE0160 T4P.  GE...P types have IP20 lug clamp/pillar terminals.  4Nm/3lbft only GE...P types.  The four-pole type (3P+N) has early-make late-break neutral pole.

11-55

11

Switch disconnectors Technical characteristics GE series 50A to 800A - Three and four switch disconnectors with fuse holder TYPE

NFC

3-pole

GE0050 F

GE0125 F

4-pole GE0050 FT4 GE0125 FT4 BS NH

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GE0200 B

GE0250 B

GE0315 B

GE0400 B

GE0630 B

GE0800 B

3-pole

-

-

GE0160 B

-

4-pole

-

-

GE0160 BT4

-

GE0160 N

GE0161 N

GE0200 BT4 GE0250 BT4 GE0315 BT4 GE0400 BT4 GE0630 BT4 GE0800 BT4

3-pole

-

-

4-pole

-

-

A

50

125

IEC rated insulation voltage Ui

V

800

800

800

1000

IEC rated impulse withstand voltage Uimp

kV

8

8

8

12

GE0160 NT4 GE0161 NT4

-

GE0250 N

-

-

GE0250 NT4

-

200

250

315

GE0400 N

GE0630 N

GE0800 N

GE0400 NT4 GE0630 NT4 GE0800 NT4

CONTACT CHARACTERISTICS IEC conventional free air thermal current Ith (40°C)

160

160

400

630

800

IEC rated operational current Ie AC21A

400V

A

50

125

160

160

200

250

315

400

630

800

500V

A

50

125

160

160

200

250

315

400

630

800

690V

A

50

125

160

160

200

250

315

400

630

630

400V

A

50

125

160

160

200

250

315

400

630

800

500V

A

50

125

160

160

200

250

315

400

630

800

690V

A

50

100

125

160

200

250

315

400

630

630

400V

A

50

125

160

160

200

250

315

400

630

630

500V

A

50

125

125

160

200

250

315

400

630

630

690V

A

50

80

100

125

160

200

250

315

400

400

kvar

18

52

60

60

75

115

150

200

250

325

IEC rated operational power AC23A 400V

kW

25

65

90

90

110

132

185

220

355

355

690V

kW

42

80

90

110

160

250

315

400

630

800

Let-through energy I2t

kA2s

0.076

0.19

0.19

0.478

0.478

1.6

1.6

1.6

4.6

4.6

IEC rated conditional short-circuit current

kA rms

50

50

100

100

100

100

100

100

100

100

IEC making capacity (AC23A 400V)

A

500

1250

1600

2000

2500

3150

4000

6300

IEC breaking capacity (AC23A 400V)

A

400

1000

1280

1600

2000

2600

3200

5100

Mechanical life

cycles

10,000

10,000

10,000

Electrical life (AC23A 400V)

cycles

1,500

1,500

1,000

Type





A mm





B mm





3

Screw

M6

M6

M8

M10

M12

4x M8

Nm

3

4

13

24

45

13

lbft

2.2

3

10

18

33

10

Maximum conductor section

mm2

35

95

95

120

240

2x185

2x240

Maximum bar size (thickness-width)

mm



3-25

3-25

5-25

6-40

2x 7-50

2x 7-50

AC22A

AC23A

IEC reactive power 400V for capacitor control

Protection against short-circuit

Terminals

B

11

A

Tightening torque

20

25

Operating

°C

-25…+55

Storage

°C

-40…+70

m

3000

Maximum altitude Mounting position Normal Admissible Fixing

 50kA rms for GE0160 N and GE0160 NT4.  GE...F types have IP20 lug clamp/pillar terminals.  The four-pole type (3P+N) has early-make late-break neutral pole.

11-56

500

Terminal for lugs or bars

AMBIENT CONDITIONS Temperature

5,000 1,000

Vertical Any Screw

30

35

4

5

40

50 6

Switch disconnectors Technical characteristics GE series 160A to 1600A - Three and four-pole changeover switches TYPE

3-pole

GE0160 E

GE0200 E

GE0201 E

GE0250 E

GE0315 E

GE0400 E

GE0500 E

GE0630 E

GE0800 E

GE1000 E

GE1250 E

GE1600 E

4-pole GE0160 ET4 GE0200 ET4 GE0201 ET4 GE0250 ET4 GE0315 ET4 GE0400 ET4 GE0500 ET4 GE0630 ET4 GE0800 ET4 GE1000 ET4 GE1250 ET4 GE1600 ET4 CONTACT CHARACTERISTICS IEC conventional free air current Ith (40°C)

A

160

200

250

315

400

500

630

800

IEC rated insulation voltage Ui

V

1000

1000

IEC rated impulse withstand voltage Uimp

kV

8

12

1000

1250

1600

IEC rated operational current Ie AC21A

AC22A

AC23B

400V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

500V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

690V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

400V

A

160

200

200

250

315

400

500

630

800

1000

1250

1600

500V

A

160

200

200

250

315

400

500

630

800

1000

1250

1250

690V

A

125

160

160

200

250

315

400

500

630

800

1000

1000

400V

A

160

160

160

180

200

250

400

500

630

1000

1000

1000

500V

A

125

125

125

150

160

200

250

315

400

800

800

900

690V

A

80

80

80

100

125

160

200

250

315

630

630

630

kvar

72

72

83

104

131

166

208

262

333

415

415

450

IEC reactive power 400V for capacitor control IEC rated operational power AC23A

400V

kW

89

89

100

100

125

125

200

200

315

500

525

550

690V

kW

76

76

69

86

108

138

173

216

272

544

575

600

IEC rated short-time withstand current (1s) Icw

kA rms

7

7

IEC rated conditional short-circuit current 

kA rms

100

Protection against short-circuit

With fuse class gG IEC making capacity (AC23A 400V) IEC breaking capacity (AC23A 400V)

8

13

25

35

100

A

160

200

250

A

1600

1600

3150 2520

315

800

1000

1250

2x800

4000

400

500 6300

630

8000

10000

10000

10000

3200

5040

6400

8000

8000

8000

A

1280

1280

Mechanical life

cycles

30,000

30,000

10,000

10,000

Electrical life (AC22A 400V)

cycles

1,000

1,000

1,000

500

Type

B

Terminals

Terminal for lugs or bars

A mm

18

B mm

3

3

Screw

M8

M10

Nm

13

24

lbft

10

18

33

Maximum conductor section

mm2

95

120

240

2x240

Maximum bar size (thickness-width)

mm

4-13

13-18

2x 5-30

2x 6-45

A

Tightening torque

11

72

26

25

35

40

50

60

5

6

10

M12

M14

M14

45

55



40 –

2x 10-60

– 2x 7-80

AMBIENT CONDITIONS Temperature

Operating

°C

-25…+55

Storage

°C

-40…+70

Maximum altitude Mounting position

m Normal Admissible

Fixing

3000 Vertical Any Screw

 With protection fuse to limit current peak and let-through energy.  The four-pole type (3P+N) has early-make late-break neutral pole.  Values in IEC DC22B duty.

11-57

Switch disconnectors Technical characteristics GA series for photovoltaic applications TYPE

Three-pole

GA040 D

GA080 D

GA125 D

4th-pole

GAX42 040 D

GAX42 080 D

GAX42 125 D

A

40

80

125

CONTACT CHARACTERISTICS IEC conventional free air thermal current Ith (40°C) IEC rated insulation voltage Ui

V

1000

IEC rated impulse withstand voltage Uimp

kV

8

IEC rated operational current Ie DC21B 2 poles in series

300V

A

16

20

25

3 poles in series

48V

A

40

80

125

110V

A

35

70

120

220V

A

32

40

95

500V

A

12

15

20

400V

A

35

40

64

440V

A

32

40

64

500V

A

32

40

56

600V

A

20

30

40

700V

A

15

18

20

750V

A

15

18

20

800V

A

15

18

20

1000V

A

––

12

15

600V

A

35

45

50

700V

A

30

35

40

750V

A

25

35

40

800V

A

25

35

40

1000V

A

10

20

25

4 poles in series

6 poles in series

11

700V

A

40

60

80

750V

A

35

50

60

800V

A

35

50

60

1000V

A

25

32

40

UL/CSA general use at 600V

A

40

100

100

UL/CSA short-circuit rating at 600V

kA

5

10

10

Type/A

RK5 / 45

– / 100

– / 100

HP

2

3

71/2

8 poles in series

UL/CSA fuse class / max rating at 600V UL/CSA HP ratings

120V

Single phase

240V

HP

5

10

10

Three phase 200-208V

HP

10

25

25

240V

HP

15

30

30

480V

HP

20

40

50

600V

HP

25

40

cycles

100,000

Mechanical life

Lug clamp 

Type B

Terminals

A

40 30,000

A mm

5.6 (0.22”)

12.4 (0.49”)

B mm

6.5 (0.26”)

10.4 (0.41”)

Screw

M4

M8

Tool

Phillips 2

Metric Allen key 4

Tightening torque min...max

Nm

1.8...2

5...6

lbin

16...18

45...54

Conductor section min...max (flexible/rigid)

mm2

0.75...16

4...50

AWG

18...6

12...1

AMBIENT CONDITIONS Temperature

Operating

°C

-25…+55

Storage

°C

-40…+70

Maximum altitude Mounting position

m Normal Admissible

Fixing    

3000 Vertical Any By screw or on 35mm DIN rail (IEC/EN 60715)

Using two pieces of 3-pole switch disconnectors mechanically coupled together by GAX60 00 / GAX60 01. Using two pieces of 3-pole switch disconnectors, each with the fourth-pole add-on, mechanically coupled together by GAX60 00 / GAX60 01. Voltage value is not considered in standards UL98/CSA C22.2 n° 4 so not indicated in UL product marking. IEC/EN 60947-1 designation: Pillar terminal.

11-58

Switch disconnectors Technical characteristics GE series for photovoltaic applications TYPE

4-pole

GE0160 DT4P GE0160 DT4

GE0125 DT4

GE0250 DT4

GE0315 DT4

GE0630 DT4

GE0800 DT4

GE1250 DT4

160

125

250

315

630

800

1250

CONTACT CHARACTERISTICS Conventional free air thermal current Ith (40°C)

A

Rated insulation voltage Ui

V

Rated impulse withstand voltage Uimp

kV

Rated operational current Ie DC21B

12

48V

A

160

125

250

315

630

800

1250

110V

A

160

125

250

315

630

800

1250

220V

A

160

125

250

315

630

800

1250

400V

A

160

125

250

315

630

800

1250

440V

A

150

125

250

315

630

750

1250

500V

A

150

125

250

315

630

700

1250

600V

A

150

125

250

315

630

700

1250

750V

A

80

125

250

290

630

650

1050

800V

A

70

125

250

280

600

630

1000

850V

A

45

125

240

270

600

630

940

900V

A

40

125

220

260

600

630

870

1000V

A

30

100

200

250

600

630

850

cycles

30,000

4 poles in series

Mechanical life

20,000

Type

B

Terminals

1000 8

10,000 Terminal for lugs or bars

A mm

18

20

25

30

B mm

3

4

4

5

Screw

M8

M8

Tightening torque

Nm

13

13

lbft

10

10

18

33

Maximum bar size (thickness-width)

mm

5-25

7-25

2x 5-40

2x 10-50

Maximum conductor section

mm2

95

185

2x240

2x300

A

M10 18

8 M14

24

13

40

45

AMBIENT CONDITIONS Temperature

Operating

°C

-25…+55

Storage

°C

-40…+70

Maximum altitude Mounting position

m Normal Admissible

Fissaggio

3000 Vertical Any Screw

 4Nm/3lbft only for GE0160 DT4P.  GE0160 DT4P type has lug clamp/pillar terminals, IP20.  Not suitable with GE0160 DT4P.