PACKAGE HEAT PUMPS FORM NO. P22-764 REV. 4 Supersedes Form No. P22-764 Rev. 3
RQNA- HIGH EFFICIENCY 13-SEER SERIES NOMINAL SIZES 2-4 TONS [7.03-14.07 kW]
TABLE OF CONTENTS
Unit Features & Benefits ..............................................................................3-4 Model Identification Options ..........................................................................5-6 General Data RQNA- Series ..........................................................................................7-8 General Data Notes ........................................................................................9 Performance Data RQNA- Series ......................................................................................10-14 Airflow Performance RQNA- Series ......................................................................................15-16 Electrical Data RQNA- Series............................................................................................17 Electric Heater Kits ..................................................................................18-19 Dimensional Data ....................................................................................20-21 Typical Installations ......................................................................................22 Accessories ............................................................................................23-31 Typical Wiring ..........................................................................................32-35 Limited Warranty ..........................................................................................36
2
UNIT FEATURES & BENEFITS—RQNA-
These quality features are included in the Ruud Outdoor Package Heat Pumps 5
4
3
UNIT FEATURES & BENEFITS—RQNA- SERIES
Features Below Correspond to Photos on Page 3 1. All models feature Scroll® compressors for maximum efficiency and quiet operation.
8. Refrigerant connections are conveniently located for easy service diagnostics.
2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes.
9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency.
3. One-piece top with a deep flange to help keep water out of the unit.
10. Supplemental electric heat strips up to 15 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring makes installation even easier.
4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. 5. Access panels have “weep holes” and channels to further help manage water run-off.
11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap.
6. Side and down discharge options available on all models. (Shipped Downflow Standard).
12. Easily accessible control box.
7. Easily accessible blower section complete with slideout blower. All units feature a system matched indoor coil with low static pressure drop and excellent cooling capacities.
4
MODEL IDENTIFICATION—RQNA- SERIES
R Q N A — 036 J K 000 XXX Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat (024-048) 015 = 15 KW Resistance Heat (036-048) Drive Package K = Direct Drive Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH—60 Hz Cooling Capacity (BTUH) [kW] 024 = 24,000 [7.03] 030 = 30,000 [8.79] 036 = 36,000 [10.55] 042 = 42,000 [12.31] 048 = 48,000 [14.07] Design Series A = 1st Design Efficiency Designation N = 13 SEER High Efficiency Product Classification Q = Package Heat Pump Tradebrand R = Ruud
[ ] Designates Metric Conversions
5
OPTIONS—RQNA- SERIES Instructions for Factory Installed Option(s) Selection Note: Two characters following the model number will be utilized to designate a factory-installed option or combination of options. If no factory option(s) is required, nothing follows the model number. Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE.
FACTORY INSTALLED OPTION CODES Option Code AA AKA
Side Flow No Option x
Example: RQNA-036JK000XX (where XX is factory installed option) Example: No Options RQNA-036JK000 Example: Options with Sideflow RQNA-036JK000AKA Note: Factory installed economizer is not available on these models.
6
GENERAL DATA—RQNA- SERIES NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQNA- Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2
B024JK
B030JK
B036CK
B036JK
24,400 [7.15] 11/13
31,400 [9.2] 11/13
36,600 [10.72] 11/13
CONTINUED 36,600 [10.72] 11/13
800/800 [378/378] 23,600 [6.91]
1000/1050 [472/495] 30,200 [8.85]
1200/1200 [566/566] 35,400 [10.37]
1200/1200 [566/566] 35,400 [10.37]
Net Sensible Capacity Btu [kW]
17,900 [5.24]
22,100 [6.48]
26,300 [7.71]
26,300 [7.71]
Net Latent Capacity Btu [kW]
5,700 [1.67]
8,100 [2.37]
9,100 [2.67]
9,100 [2.67]
2.14
2.74
3.22
3.22
23,000 [6.74] 1.95/3.4 12,900 [3.78]
29,000 [8.5] 2.44/3.4 16,100 [4.72]
34,200 [10.02] 2.91/3.4 19,500 [5.71]
34,200 [10.02] 2.91/3.4 19,500 [5.71]
1.89/2
2.29/2
2.72/2.1
2.72/2.1
7.7
7.7
7.7
7.7
1/Scroll 76
1/Scroll 76
1/Scroll 76
1/Scroll 76
Louvered
Louvered
Louvered
Louvered
Rifled 0.375 [9.5] 14.51 [1.35] 1 / 22 [9]
Rifled 0.375 [9.5] 16.32 [1.52] 1 / 22 [9]
Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9]
Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9]
Refrigerant Control
TX Valves
TX Valves
TX Valves
TX Valves
Indoor Coil—Fin Type Tube Type Tube Size in. [mm]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
5.54 [0.51]
7.39 [0.69]
7.39 [0.69]
7.39 [0.69]
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
1/22 [558.8]
1/22 [558.8]
1/22 [558.8]
1/22 [558.8]
Direct/1
Direct/1
Direct/1
Direct/1
2700 [1274] 1 at 1/5 HP
2700 [1274] 1 at 1/5 HP
2700 [1274] 1 at 1/5 HP
2700 [1274] 1 at 1/5 HP
Nominal CFM/ARI Rated CFM [L/s] ARI Net Cooling Capacity Btu [kW]
Net System Power kW Heating Performance (Heat Pumps) Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm]
Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds CFM [L/s] No. Motors/HP Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished
1075
1075
1075
1075
FC Centrifugal 1/9x7 [228.6x177.8] Direct/2
FC Centrifugal 1/10x9 [254x228.6] Direct/3
FC Centrifugal 1/10x9 [254x228.6] Direct/1
FC Centrifugal 1/10x9 [254x228.6] Direct/1
1
1
1
1
1/4
1/2
1/3
1/3
1075
1075
1075
1075
48 Field Supplied
48 Field Supplied
48 Field Supplied
48 Field Supplied
No
No
No
No
(1)1x20x20 [25x508x508]
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
86 [2438]
93 [2637]
122 [3459]
122 [3459]
Net Weight lbs. [kg]
391 [177]
444 [201]
471 [214]
468 [212]
Ship Weight lbs. [kg]
401 [182]
455 [206]
482 [219]
479 [217]
(No.) Size Recommended in. [mm] Refrigerant Charge Oz. [g] Weights
[ ] Designates Metric Conversions
See Page 9 for Notes.
7
GENERAL DATA—RQNA- SERIES NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQNA- Series
B042CK
B042JK
B048CK
B048JK
44,500 [13.04] 11/13
44,500 [13.04] 11/13
50,000 [14.65] 11/13
50,000 [14.65] 11/13
1400/1400 [661/661] 43,500 [12.75]
1400/1400 [661/661] 43,500 [12.75]
1600/1600 [755/755] 48,500 [14.21]
1600/1600 [755/755] 48,500 [14.21]
Net Sensible Capacity Btu [kW]
31,800 [9.32]
31,800 [9.32]
36,000 [10.55]
36,000 [10.55]
Net Latent Capacity Btu [kW]
11,700 [3.43]
11,700 [3.43]
12,500 [3.66]
12,500 [3.66]
3.96
3.96
4.41
4.41
39,500 [11.57] 3.34/3.4 22,800 [6.68]
39,500 [11.57] 3.34/3.4 22,800 [6.68]
46,000 [13.48] 4.11/3.28 27,400 [8.03]
46,000 [13.48] 4.11/3.28 28,000 [8.2]
3.18/2.1
3.18/2.1
3.86/2.08
3.86/2.08
7.7
7.7
7.7
7.7
1/Scroll 76
1/Scroll 76
1/Scroll 78
1/Scroll 78
Louvered
Louvered
Louvered
Louvered
Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9]
Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9]
Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9]
Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9]
Refrigerant Control
TX Valves
TX Valves
TX Valves
TX Valves
Indoor Coil—Fin Type Tube Type Tube Size in. [mm]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
Louvered Rifled 0.375 [9.5]
7.39 [0.69]
7.39 [0.69]
7.39 [0.69]
7.39 [0.69]
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
2 / 15 [6] TX Valves 1/1 [25.4] Propeller
1/22 [558.8]
1/22 [558.8]
1/22 [558.8]
1/22 [558.8]
Direct/1
Direct/1
Direct/1
Direct/1
3300 [1557] 1 at 1/3 HP
3300 [1557] 1 at 1/3 HP
3000 [1416] 1 at 1/3 HP
3000 [1416] 1 at 1/3 HP
Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/ARI Rated CFM [L/s] ARI Net Cooling Capacity Btu [kW]
Net System Power kW Heating Performance (Heat Pumps) Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm]
Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds CFM [L/s] No. Motors/HP Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished
1075
1075
1075
1075
FC Centrifugal 1/10x9 [254x228.6] Direct/2
FC Centrifugal 1/10x9 [254x228.6] Direct/2
FC Centrifugal 1/10x9 [254x228.6] Direct/2
FC Centrifugal 1/10x9 [254x228.6] Direct/2
1
1
1
1
3/4
3/4
3/4
3/4
1075
1075
1725
1075
48 Field Supplied
48 Field Supplied
48 Field Supplied
48 Field Supplied
No
No
No
No
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
158 [4479]
158 [4479]
150 [4252]
150 [4252]
Net Weight lbs. [kg]
508 [230]
505 [229]
500 [227]
510 [231]
Ship Weight lbs. [kg]
519 [235]
516 [234]
511 [232]
521 [236]
(No.) Size Recommended in. [mm] Refrigerant Charge Oz. [g] Weights
[ ] Designates Metric Conversions
See Page 9 for Notes.
8
GENERAL DATA—RQNA- SERIES NOTES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360. 2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. 3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
9
SYSTEMS PERFORMANCE—RQNA- SERIES COOLING PERFORMANCE DATA—RQNA-024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀
900 [425] .19
71°F [21.7°C] 800 [378] .16
700 [330] .11
900 [425] .19
67°F [19.4°C] 800 [378] .16
700 [330] .11
900 [425] .19
63°F [17.2°C] 800 [378] .16
700 [330] .11
Total BTUH [kW] 75 Sens BTUH [kW] [23.9] Power
31.4 [9.20] 18.2 [5.33] 1.6
30.7 [9.00] 17.2 [5.04] 1.5
30.0 [8.79] 16.2 [4.75] 1.5
29.1 [8.53] 21.6 [6.33] 1.6
28.4 [8.32] 20.4 [5.98] 1.5
27.8 [8.15] 19.2 [5.63] 1.5
28.6 [8.38] 23.3 [6.83] 1.5
28.0 [8.21] 22.0 [6.45] 1.5
27.4 [8.03] 20.7 [6.07] 1.5
Total BTUH [kW] 80 Sens BTUH [kW] [26.7] Power
30.5 [8.94] 18.0 [5.28] 1.6
29.8 [8.73] 17.0 [4.98] 1.6
29.2 [8.56] 16.0 [4.69] 1.6
28.2 [8.26] 21.4 [6.27] 1.6
27.6 [8.09] 20.2 [5.92] 1.6
27.0 [7.91] 19.0 [5.57] 1.6
27.8 [8.15] 23.1 [6.77] 1.6
27.2 [7.97] 21.8 [6.39] 1.6
26.5 [7.77] 20.5 [6.01] 1.6
Total BTUH [kW] 85 Sens BTUH [kW] [29.4] Power
29.5 [8.65] 17.6 [5.16] 1.7
28.8 [8.44] 16.6 [4.86] 1.7
28.2 [8.26] 15.7 [4.60] 1.7
27.2 [7.97] 21.0 [6.15] 1.7
26.6 [7.80] 19.8 [5.80] 1.7
26.0 [7.62] 18.7 [5.48] 1.7
26.8 [7.85] 22.7 [6.65] 1.7
26.2 [7.68] 21.4 [6.27] 1.7
25.6 [7.50] 20.2 [5.92] 1.7
Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power
28.4 [8.32] 17.1 [5.01] 1.8
27.8 [8.15] 16.1 [4.72] 1.8
27.1 [7.94] 15.2 [4.45] 1.8
26.1 [7.65] 20.4 [5.98] 1.8
25.5 [7.47] 19.3 [5.66] 1.8
25.0 [7.33] 18.2 [5.33] 1.8
25.7 [7.53] 22.1 [6.48] 1.8
25.1 [7.36] 20.9 [6.13] 1.8
24.5 [7.18] 19.7 [5.77] 1.8
27.3 [8.00] 16.5 [4.84] 1.9
26.7 [7.83] 15.6 [4.57] 1.9
26.1 [7.65] 14.7 [4.31] 1.9
25.0 [7.33] 19.9 [5.83] 1.9
24.5 [7.18] 18.8 [5.51] 1.9
23.9 [7.00] 17.7 [5.19] 1.9
24.6 [7.21] 21.6 [6.33] 1.9
24.0 [7.03] 20.4 [5.98] 1.9
23.5 [6.89] 19.2 [5.63] 1.9
26.3 [7.71] 15.9 [4.66] 2.0
25.7 [7.53] 15.0 [4.40] 2.0
25.1 [7.36] 14.1 [4.13] 2.0
24.0 [7.03] 19.2 [5.63] 2.0
23.5 [6.89] 18.2 [5.33] 2.0
22.9 [6.71] 17.1 [5.01] 2.0
23.5 [6.89] 20.9 [6.13] 2.0
23.0 [6.74] 19.8 [5.80] 2.0
22.5 [6.59] 18.6 [5.45] 2.0
Total BTUH [kW] 105 Sens BTUH [kW] [40.6] Power
25.4 [7.44] 15.3 [4.48] 2.1
24.9 [7.30] 14.5 [4.25] 2.1
24.3 [7.12] 13.6 [3.99] 2.0
23.1 [6.77] 18.7 [5.48] 2.1
22.6 [6.62] 17.6 [5.16] 2.1
22.1 [6.48] 16.6 [4.86] 2.0
22.7 [6.65] 20.4 [5.98] 2.1
22.2 [6.51] 19.2 [5.63] 2.1
21.7 [6.36] 18.1 [5.30] 2.0
Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power
24.8 [7.27] 14.8 [4.34] 2.2 24.5 [7.18] 14.4 [4.22] 2.3
24.3 [7.12] 14.0 [4.10] 2.2 24.0 [7.03] 13.6 [3.99] 2.2
23.7 [6.95] 13.2 [3.87] 2.1 23.4 [6.86] 12.8 [3.75] 2.2
22.5 [6.59] 18.1 [5.30] 2.2 22.2 [6.51] 17.8 [5.22] 2.3
22.0 [6.45] 17.1 [5.01] 2.2 21.7 [6.36] 16.8 [4.92] 2.2
21.5 [6.30] 16.1 [4.72] 2.1 21.3 [6.24] 15.8 [4.63] 2.2
22.1 [6.48] 19.8 [5.80] 2.2 21.8 [6.39] 19.5 [5.71] 2.3
21.6 [6.33] 18.7 [5.48] 2.1 21.3 [6.24] 18.4 [5.39] 2.2
21.1 [6.18] 17.7 [5.19] 2.1 20.8 [6.10] 17.3 [5.07] 2.2
O U T D O O R D R Y B U L B T E M P E R A T U R E
DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RQNA-024 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C]
0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10]
Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power
900 [425]
60°F [15.5°C] 800 [378]
700 [330]
900 [425]
70°F [21.1°C] 800 [378]
700 [330]
900 [425]
80°F [26.7°C] 800 [378]
700 [330]
7.8 [2.29] 1.2 9.4 [2.75] 1.3 10.9 [3.19] 1.3 12.4 [3.63] 1.3 13.9 [4.07] 1.3 15.4 [4.51] 1.4 17.0 [4.98] 1.4 18.6 [5.45] 1.4 20.3 [5.95] 1.4 22.2 [6.51] 1.5 24.3 [7.12] 1.5
7.7 [2.26] 1.2 9.3 [2.73] 1.3 10.8 [3.17] 1.3 12.3 [3.60] 1.3 13.8 [4.04] 1.4 15.3 [4.48] 1.4 16.8 [4.92] 1.4 18.4 [5.39] 1.4 20.2 [5.92] 1.5 22.0 [6.45] 1.5 24.1 [7.06] 1.5
7.6 [2.23] 1.3 9.2 [2.70] 1.3 10.7 [3.14] 1.3 12.2 [3.58] 1.4 13.6 [3.99] 1.4 15.1 [4.43] 1.4 16.7 [4.89] 1.4 18.3 [5.36] 1.5 20.0 [5.86] 1.5 21.8 [6.39] 1.5 23.9 [7.00] 1.5
7.1 [2.08] 1.4 8.7 [2.55] 1.4 10.2 [2.99] 1.5 11.7 [3.43] 1.5 13.2 [3.87] 1.5 14.7 [4.31] 1.6 16.3 [4.78] 1.6 17.9 [5.25] 1.6 19.7 [5.77] 1.6 21.5 [6.30] 1.7 23.6 [6.92] 1.7
7.0 [2.05] 1.4 8.6 [2.52] 1.5 10.1 [2.96] 1.5 11.6 [3.40] 1.5 13.1 [3.84] 1.6 14.6 [4.28] 1.6 16.1 [4.72] 1.6 17.7 [5.19] 1.6 19.5 [5.71] 1.7 21.3 [6.24] 1.7 23.4 [6.86] 1.7
7.0 [2.05] 1.5 8.5 [2.49] 1.5 10.0 [2.93] 1.5 11.5 [3.37] 1.5 13.0 [3.81] 1.6 14.4 [4.22] 1.6 16.0 [4.69] 1.6 17.6 [5.16] 1.7 19.3 [5.66] 1.7 21.2 [6.21] 1.7 23.2 [6.80] 1.7
5.8 [1.70] 1.5 7.4 [2.17] 1.6 8.9 [2.61] 1.6 10.4 [3.05] 1.6 11.9 [3.49] 1.7 13.4 [3.93] 1.7 15.0 [4.40] 1.7 16.6 [4.86] 1.7 18.4 [5.39] 1.8 20.3 [5.95] 1.8 22.3 [6.54] 1.8
5.8 [1.70] 1.6 7.3 [2.14] 1.6 8.9 [2.61] 1.6 10.3 [3.02] 1.7 11.8 [3.46] 1.7 13.3 [3.90] 1.7 14.9 [4.37] 1.7 16.5 [4.84] 1.8 18.2 [5.33] 1.8 20.1 [5.89] 1.8 22.1 [6.48] 1.8
5.7 [1.67] 1.6 7.3 [2.14] 1.6 8.8 [2.58] 1.6 10.2 [2.99] 1.7 11.7 [3.43] 1.7 13.2 [3.87] 1.7 14.7 [4.31] 1.8 16.3 [4.78] 1.8 18.1 [5.30] 1.8 19.9 [5.83] 1.8 21.9 [6.42] 1.9
IDB—Indoor air dry bulb
[ ] Designates Metric Conversions
10
SYSTEMS PERFORMANCE—RQNAINTRODUCTION SERIES COOLING PERFORMANCE DATA—RQNA-030 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀
O U T D O O R D R Y B U L B T E M P E R A T U R E
71°F [21.7°C] 1050 [496] .16
920 [434] .11
1180 [557] .19
67°F [19.4°C] 1050 [496] .16
920 [434] .11
1180 [557] .19
63°F [17.2°C] 1050 [496] .16
920 [434] .11
Total BTUH [kW] 37.6 [11.02] 75 Sens BTUH [kW] 22.4 [6.56] [23.9] 1.9 Power
36.8 [10.79] 21.2 [6.21] 1.9
35.9 [10.52] 19.9 [5.83] 1.9
35.2 [10.32] 26.5 [7.77] 1.9
34.4 [10.08] 25.0 [7.33] 1.9
33.6 [9.85] 23.6 [6.92] 1.9
34.1 [9.99] 28.8 [8.44] 1.9
33.3 [9.76] 27.2 [7.97] 1.9
32.5 [9.52] 25.6 [7.50] 1.9
Total BTUH [kW] 37.4 [10.96] 80 Sens BTUH [kW] 22.4 [6.56] [26.7] 2.1 Power
36.6 [10.73] 21.2 [6.21] 2.0
35.7 [10.46] 19.9 [5.83] 2.0
35.0 [10.26] 26.5 [7.77] 2.1
34.2 [10.02] 25.0 [7.33] 2.0
33.5 [9.82] 23.6 [6.92] 2.0
33.9 [9.94] 28.8 [8.44] 2.1
33.1 [9.70] 27.2 [7.97] 2.0
32.4 [9.50] 25.6 [7.50] 2.0
Total BTUH [kW] 36.7 [10.76] 85 Sens BTUH [kW] 22.0 [6.45] [29.4] 2.2 Power
35.9 [10.52] 20.8 [6.10] 2.2
35.1 [10.29] 19.6 [5.74] 2.1
34.4 [10.08] 26.1 [7.65] 2.2
33.6 [9.85] 24.7 [7.24] 2.2
32.8 [9.61] 23.2 [6.80] 2.1
33.2 [9.73] 28.4 [8.32] 2.2
32.5 [9.52] 26.9 [7.88] 2.1
31.7 [9.29] 25.3 [7.41] 2.1
Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power
35.7 [10.46] 21.4 [6.27] 2.3
34.9 [10.23] 20.2 [5.92] 2.3
34.2 [10.02] 19.0 [5.57] 2.3
33.3 [9.76] 25.5 [7.47] 2.3
32.6 [9.55] 24.1 [7.06] 2.3
31.9 [9.35] 22.7 [6.65] 2.3
32.2 [9.44] 27.8 [8.15] 2.3
31.5 [9.23] 26.3 [7.71] 2.3
30.8 [9.03] 24.7 [7.24] 2.2
34.5 [10.11] 20.6 [6.04] 2.4
33.7 [9.88] 19.5 [5.71] 2.4
33.0 [9.67] 18.3 [5.36] 2.4
32.1 [9.41] 24.7 [7.24] 2.4
31.4 [9.20] 23.3 [6.83] 2.4
30.7 [9.00] 21.9 [6.42] 2.4
31.0 [9.09] 27.0 [7.91] 2.4
30.3 [8.88] 25.5 [7.47] 2.4
29.6 [8.67] 24.0 [7.03] 2.4
33.2 [9.73] 19.7 [5.77] 2.5
32.4 [9.50] 18.6 [5.45] 2.5
31.7 [9.29] 17.6 [5.16] 2.5
30.8 [9.03] 23.8 [6.98] 2.5
30.1 [8.82] 22.5 [6.59] 2.5
29.4 [8.62] 21.2 [6.21] 2.5
29.6 [8.67] 26.1 [7.65] 2.5
29.0 [8.50] 24.7 [7.24] 2.5
28.3 [8.29] 23.3 [6.83] 2.5
Total BTUH [kW] 31.8 [9.32] 105 Sens BTUH [kW] 18.9 [5.54] [40.6] 2.7 Power
31.1 [9.11] 17.9 [5.25] 2.6
30.4 [8.91] 16.8 [4.92] 2.6
29.4 [8.62] 23.0 [6.74] 2.7
28.8 [8.44] 21.7 [6.36] 2.6
28.1 [8.24] 20.5 [6.01] 2.6
28.3 [8.29] 25.3 [7.41] 2.6
27.7 [8.12] 23.9 [7.00] 2.6
27.0 [7.91] 22.5 [6.59] 2.6
29.9 [8.76] 17.3 [5.07] 2.8 29.0 [8.50] 16.9 [4.95] 2.9
29.2 [8.56] 16.3 [4.78] 2.7 28.3 [8.29] 15.9 [4.66] 2.8
28.2 [8.26] 22.3 [6.54] 2.8 27.2 [7.97] 21.9 [6.42] 2.9
27.6 [8.09] 21.1 [6.18] 2.7 26.6 [7.80] 20.7 [6.07] 2.9
26.9 [7.88] 19.9 [5.83] 2.7 26.0 [7.62] 19.5 [5.71] 2.8
27.1 [7.94] 24.7 [7.24] 2.8 26.1 [7.65] 24.3 [7.12] 2.9
26.5 [7.77] 23.3 [6.83] 2.7 25.5 [7.47] 22.9 [6.71] 2.9
25.9 [7.59] 21.9 [6.42] 2.7 24.9 [7.30] 21.6 [6.33] 2.8
Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb
1180 [557] .19
30.6 [8.97] 18.3 [5.36] 2.8 29.6 [8.67] 17.9 [5.25] 2.9
Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RQNA-030 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C]
0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10]
Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power
1180 [557]
60°F [15.5°C] 1050 [496]
920 [434]
1180 [557]
70°F [21.1°C] 1050 [496]
920 [434]
1180 [557]
80°F [26.7°C] 1050 [496]
920 [434]
9.7 [2.84] 1.5 11.8 [3.46] 1.5 13.8 [4.04] 1.5 15.7 [4.60] 1.6 17.6 [5.16] 1.6 19.5 [5.71] 1.7 21.5 [6.30] 1.7 23.6 [6.92] 1.7 25.8 [7.56] 1.8 28.1 [8.24] 1.8 30.7 [9.00] 1.8
9.7 [2.84] 1.5 11.7 [3.43] 1.5 13.7 [4.02] 1.6 15.6 [4.57] 1.6 17.5 [5.13] 1.6 19.4 [5.69] 1.7 21.3 [6.24] 1.7 23.4 [6.86] 1.8 25.5 [7.47] 1.8 27.9 [8.18] 1.8 30.4 [8.91] 1.9
9.6 [2.81] 1.5 11.6 [3.40] 1.6 13.6 [3.99] 1.6 15.4 [4.51] 1.6 17.3 [5.07] 1.7 19.2 [5.63] 1.7 21.1 [6.18] 1.7 23.2 [6.80] 1.8 25.3 [7.41] 1.8 27.6 [8.09] 1.9 30.2 [8.85] 1.9
8.7 [2.55] 1.7 10.7 [3.14] 1.7 12.7 [3.72] 1.8 14.7 [4.31] 1.8 16.6 [4.86] 1.9 18.5 [5.42] 1.9 20.4 [5.98] 1.9 22.5 [6.59] 2.0 24.7 [7.24] 2.0 27.1 [7.94] 2.0 29.6 [8.67] 2.1
8.6 [2.52] 1.7 10.7 [3.14] 1.8 12.6 [3.69] 1.8 14.5 [4.25] 1.8 16.4 [4.81] 1.9 18.3 [5.36] 1.9 20.3 [5.95] 2.0 22.3 [6.54] 2.0 24.5 [7.18] 2.0 26.8 [7.85] 2.1 29.4 [8.62] 2.1
8.5 [2.49] 1.8 10.6 [3.11] 1.8 12.5 [3.66] 1.8 14.4 [4.22] 1.9 16.3 [4.78] 1.9 18.1 [5.30] 2.0 20.1 [5.89] 2.0 22.1 [6.48] 2.0 24.3 [7.12] 2.1 26.6 [7.80] 2.1 29.1 [8.53] 2.1
8.0 [2.34] 1.9 10.1 [2.96] 1.9 12.0 [3.52] 2.0 14.0 [4.10] 2.0 15.9 [4.66] 2.0 17.8 [5.22] 2.1 19.8 [5.80] 2.1 21.8 [6.39] 2.1 24.0 [7.03] 2.2 26.4 [7.74] 2.2 28.9 [8.47] 2.3
7.9 [2.32] 1.9 10.0 [2.93] 1.9 11.9 [3.49] 2.0 13.8 [4.04] 2.0 15.7 [4.60] 2.1 17.6 [5.16] 2.1 19.6 [5.74] 2.1 21.6 [6.33] 2.2 23.8 [6.98] 2.2 26.1 [7.65] 2.3 28.7 [8.41] 2.3
7.8 [2.29] 1.9 9.9 [2.90] 2.0 11.8 [3.46] 2.0 13.7 [4.02] 2.1 15.6 [4.57] 2.1 17.5 [5.13] 2.1 19.4 [5.69] 2.2 21.4 [6.27] 2.2 23.6 [6.92] 2.2 25.9 [7.59] 2.3 28.4 [8.32] 2.3
IDB—Indoor air dry bulb
[ ] Designates Metric Conversions
11
SYSTEMS PERFORMANCE—RQNA- SERIES COOLING PERFORMANCE DATA—RQNA-036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀
O U T D O O R D R Y B U L B T E M P E R A T U R E
71°F [21.7°C] 1200 [566] .16
1050 [496] .11
1350 [637] .19
67°F [19.4°C] 1200 [566] .16
1050 [496] .11
1350 [637] .19
63°F [17.2°C] 1200 [566] .16
1050 [496] .11
Total BTUH [kW] 46.3 [13.57] 75 Sens BTUH [kW] 26.6 [7.80] [23.9] 2.4 Power
45.3 [13.28] 25.1 [7.36] 2.4
44.3 [12.98] 23.7 [6.95] 2.4
43.0 [12.60] 31.7 [9.29] 2.4
42.1 [12.34] 29.9 [8.76] 2.4
41.1 [12.05] 28.2 [8.26] 2.3
41.4 [12.13] 33.4 [9.79] 2.4
40.4 [11.84] 31.5 [9.23] 2.4
39.5 [11.58] 29.7 [8.70] 2.4
Total BTUH [kW] 45.2 [13.25] 80 Sens BTUH [kW] 25.8 [7.56] [26.7] 2.6 Power
44.2 [12.95] 24.4 [7.15] 2.5
43.2 [12.66] 22.9 [6.71] 2.5
41.9 [12.28] 30.9 [9.06] 2.5
41.0 [12.02] 29.2 [8.56] 2.5
40.1 [11.75] 27.5 [8.06] 2.5
40.3 [11.81] 32.6 [9.55] 2.5
39.4 [11.55] 30.8 [9.03] 2.5
38.5 [11.28] 29.0 [8.50] 2.5
Total BTUH [kW] 43.9 [12.87] 85 Sens BTUH [kW] 25.1 [7.36] [29.4] 2.7 Power
42.9 [12.57] 23.8 [6.98] 2.6
41.9 [12.28] 22.4 [6.56] 2.6
40.6 [11.90] 30.2 [8.85] 2.6
39.7 [11.63] 28.5 [8.35] 2.6
38.8 [11.37] 26.9 [7.88] 2.6
38.9 [11.40] 31.9 [9.35] 2.7
38.0 [11.14] 30.2 [8.85] 2.6
37.2 [10.90] 28.4 [8.32] 2.6
Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power
42.4 [12.43] 24.6 [7.21] 2.8
41.4 [12.13] 23.3 [6.83] 2.8
40.5 [11.87] 21.9 [6.42] 2.7
39.1 [11.46] 29.7 [8.70] 2.8
38.2 [11.20] 28.0 [8.21] 2.7
37.3 [10.93] 26.4 [7.74] 2.7
37.4 [10.96] 31.4 [9.20] 2.8
36.6 [10.73] 29.7 [8.70] 2.7
35.7 [10.46] 27.9 [8.18] 2.7
40.8 [11.96] 24.1 [7.06] 2.9
39.9 [11.69] 22.8 [6.68] 2.9
39.0 [11.43] 21.5 [6.30] 2.9
37.5 [10.99] 29.2 [8.56] 2.9
36.7 [10.76] 27.6 [8.09] 2.8
35.8 [10.49] 26.0 [7.62] 2.8
35.8 [10.49] 30.9 [9.06] 2.9
35.0 [10.26] 29.2 [8.56] 2.9
34.2 [10.02] 27.5 [8.06] 2.8
39.3 [11.52] 23.6 [6.92] 3.0
38.4 [11.25] 22.3 [6.54] 3.0
37.5 [10.99] 21.0 [6.15] 3.0
36.0 [10.55] 28.7 [8.41] 3.0
35.2 [10.32] 27.1 [7.94] 3.0
34.4 [10.08] 25.5 [7.47] 2.9
34.3 [10.05] 30.4 [8.91] 3.0
33.5 [9.82] 28.7 [8.41] 3.0
32.8 [9.61] 27.0 [7.91] 2.9
Total BTUH [kW] 37.8 [11.08] 105 Sens BTUH [kW] 23.0 [6.74] [40.6] 3.2 Power
37.0 [10.84] 21.7 [6.36] 3.1
36.2 [10.61] 20.5 [6.01] 3.1
34.5 [10.11] 28.1 [8.24] 3.1
33.8 [9.91] 26.5 [7.77] 3.1
33.0 [9.67] 25.0 [7.33] 3.0
32.9 [9.64] 29.8 [8.73] 3.1
32.1 [9.41] 28.1 [8.24] 3.1
31.4 [9.20] 26.5 [7.77] 3.1
35.8 [10.49] 21.0 [6.15] 3.2 34.9 [10.23] 20.1 [5.89] 3.4
35.0 [10.26] 19.8 [5.80] 3.2 34.1 [9.99] 18.9 [5.54] 3.3
33.3 [9.76] 27.3 [8.00] 3.2 32.4 [9.50] 26.3 [7.71] 3.4
32.6 [9.55] 25.8 [7.56] 3.2 31.7 [9.29] 24.9 [7.30] 3.3
31.8 [9.32] 24.3 [7.12] 3.2 30.9 [9.06] 23.4 [6.86] 3.3
31.6 [9.26] 29.0 [8.50] 3.3 30.7 [9.00] 28.0 [8.21] 3.4
30.9 [9.06] 27.4 [8.03] 3.2 30.0 [8.79] 26.5 [7.77] 3.3
30.2 [8.85] 25.8 [7.56] 3.2 29.3 [8.59] 25.0 [7.33] 3.3
Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb
1350 [637] .19
36.6 [10.73] 22.2 [6.51] 3.3 35.7 [10.46] 21.3 [6.24] 3.4
Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RQNA-036 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C]
0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10]
Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power
1350 [637]
60°F [15.5°C] 1200 [566]
1050 [496]
1350 [637]
70°F [21.1°C] 1200 [566]
1050 [496]
1350 [637]
80°F [26.7°C] 1200 [566]
1050 [496]
13.9 [4.07] 1.8 15.8 [4.63] 1.8 17.6 [5.16] 1.9 19.4 [5.69] 1.9 21.2 [6.21] 2.0 23.0 [6.74] 2.0 25.1 [7.36] 2.1 27.3 [8.00] 2.1 29.9 [8.76] 2.2 32.8 [9.61] 2.2 36.3 [10.64] 2.3
13.8 [4.04] 1.8 15.7 [4.60] 1.9 17.5 [5.13] 1.9 19.2 [5.63] 2.0 21.0 [6.15] 2.0 22.8 [6.68] 2.1 24.8 [7.27] 2.1 27.1 [7.94] 2.2 29.6 [8.67] 2.2 32.6 [9.55] 2.3 35.9 [10.52] 2.3
13.6 [3.99] 1.8 15.5 [4.54] 1.9 17.3 [5.07] 1.9 19.1 [5.60] 2.0 20.8 [6.10] 2.0 22.6 [6.62] 2.1 24.6 [7.21] 2.1 26.8 [7.85] 2.2 29.4 [8.62] 2.2 32.3 [9.47] 2.3 35.6 [10.43] 2.3
13.0 [3.81] 2.0 14.9 [4.37] 2.1 16.7 [4.89] 2.1 18.5 [5.42] 2.2 20.3 [5.95] 2.2 22.1 [6.48] 2.3 24.1 [7.06] 2.3 26.4 [7.74] 2.4 29.0 [8.50] 2.4 31.9 [9.35] 2.5 35.4 [10.37] 2.5
12.9 [3.78] 2.1 14.8 [4.34] 2.1 16.6 [4.86] 2.2 18.3 [5.36] 2.2 20.1 [5.89] 2.3 21.9 [6.42] 2.3 23.9 [7.00] 2.4 26.2 [7.68] 2.4 28.7 [8.41] 2.5 31.7 [9.29] 2.5 35.0 [10.26] 2.6
12.7 [3.72] 2.1 14.7 [4.31] 2.2 16.4 [4.81] 2.2 18.2 [5.33] 2.3 19.9 [5.83] 2.3 21.7 [6.36] 2.4 23.7 [6.95] 2.4 25.9 [7.59] 2.5 28.5 [8.35] 2.5 31.4 [9.20] 2.6 34.7 [10.17] 2.6
12.1 [3.55] 2.3 14.1 [4.13] 2.4 15.9 [4.66] 2.4 17.7 [5.19] 2.5 19.4 [5.69] 2.5 21.3 [6.24] 2.6 23.3 [6.83] 2.6 25.6 [7.50] 2.7 28.1 [8.24] 2.7 31.1 [9.11] 2.8 34.5 [10.11] 2.8
12.0 [3.52] 2.4 14.0 [4.10] 2.4 15.8 [4.63] 2.5 17.5 [5.13] 2.5 19.3 [5.66] 2.6 21.1 [6.18] 2.6 23.1 [6.77] 2.6 25.3 [7.41] 2.7 27.9 [8.18] 2.7 30.8 [9.03] 2.8 34.2 [10.02] 2.8
11.9 [3.49] 2.4 13.8 [4.04] 2.4 15.6 [4.57] 2.5 17.3 [5.07] 2.5 19.1 [5.60] 2.6 20.9 [6.13] 2.6 22.9 [6.71] 2.7 25.1 [7.36] 2.7 27.6 [8.09] 2.8 30.6 [8.97] 2.8 33.9 [9.94] 2.9
IDB—Indoor air dry bulb
[ ] Designates Metric Conversions
12
SYSTEMS PERFORMANCE—RQNA- SERIES COOLING PERFORMANCE DATA—RQNA-042 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀
O U T D O O R D R Y B U L B T E M P E R A T U R E
71°F [21.7°C] 1400 [661] .16
1220 [576] .11
1580 [746] .19
67°F [19.4°C] 1400 [661] .16
1220 [576] .11
1580 [746] .19
63°F [17.2°C] 1400 [661] .16
1220 [576] .11
Total BTUH [kW] 57.5 [16.85] 75 Sens BTUH [kW] 33.3 [9.76] [23.9] 3.1 Power
56.2 [16.47] 31.4 [9.20] 3.1
54.9 [16.09] 29.6 [8.67] 3.1
53.3 [15.62] 38.9 [11.40] 3.1
52.1 [15.27] 36.8 [10.79] 3.1
51.0 [14.95] 34.6 [10.14] 3.0
51.4 [15.06] 41.3 [12.10] 3.1
50.3 [14.74] 39.0 [11.43] 3.1
49.2 [14.42] 36.7 [10.76] 3.0
Total BTUH [kW] 54.2 [15.88] 80 Sens BTUH [kW] 31.6 [9.26] [26.7] 3.3 Power
53.0 [15.53] 29.8 [8.73] 3.2
51.8 [15.18] 28.1 [8.24] 3.2
50.0 [14.65] 37.2 [10.90] 3.2
48.9 [14.33] 35.2 [10.32] 3.2
47.8 [14.01] 33.1 [9.70] 3.2
48.2 [14.13] 39.6 [11.61] 3.2
47.1 [13.80] 37.4 [10.96] 3.2
46.0 [13.48] 35.2 [10.32] 3.2
Total BTUH [kW] 52.0 [15.24] 85 Sens BTUH [kW] 30.4 [8.91] [29.4] 3.4 Power
50.8 [14.89] 28.7 [8.41] 3.4
49.7 [14.57] 27.0 [7.91] 3.4
47.8 [14.01] 36.1 [10.58] 3.4
46.7 [13.69] 34.1 [9.99] 3.4
45.7 [13.39] 32.1 [9.41] 3.3
45.9 [13.45] 38.4 [11.25] 3.4
44.9 [13.16] 36.3 [10.64] 3.4
43.9 [12.87] 34.2 [10.02] 3.3
Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power
50.5 [14.80] 29.6 [8.67] 3.6
49.4 [14.48] 27.9 [8.18] 3.6
48.3 [14.16] 26.3 [7.71] 3.5
46.4 [13.60] 35.2 [10.32] 3.6
45.3 [13.28] 33.3 [9.76] 3.5
44.3 [12.98] 31.3 [9.17] 3.5
44.5 [13.04] 37.6 [11.02] 3.6
43.5 [12.75] 35.5 [10.40] 3.5
42.5 [12.46] 33.4 [9.79] 3.5
49.6 [14.54] 29.0 [8.50] 3.7
48.5 [14.21] 27.4 [8.03] 3.7
47.4 [13.89] 25.8 [7.56] 3.7
45.5 [13.33] 34.7 [10.17] 3.7
44.5 [13.04] 32.8 [9.61] 3.7
43.5 [12.75] 30.9 [9.06] 3.6
43.6 [12.78] 37.0 [10.84] 3.7
42.6 [12.48] 35.0 [10.26] 3.7
41.7 [12.22] 32.9 [9.64] 3.6
49.0 [14.36] 28.6 [8.38] 3.9
47.9 [14.04] 27.0 [7.91] 3.9
46.8 [13.72] 25.5 [7.47] 3.8
44.8 [13.13] 34.3 [10.05] 3.9
43.8 [12.84] 32.4 [9.50] 3.8
42.8 [12.54] 30.5 [8.94] 3.8
42.9 [12.57] 36.6 [10.73] 3.9
42.0 [12.31] 34.6 [10.14] 3.8
41.0 [12.02] 32.6 [9.55] 3.8
Total BTUH [kW] 48.3 [14.16] 105 Sens BTUH [kW] 28.3 [8.29] [40.6] 4.1 Power
47.2 [13.83] 26.7 [7.83] 4.0
46.1 [13.51] 25.1 [7.36] 4.0
44.1 [12.92] 33.9 [9.94] 4.0
43.2 [12.66] 32.0 [9.38] 4.0
42.2 [12.37] 30.2 [8.85] 3.9
42.3 [12.40] 36.3 [10.64] 4.0
41.3 [12.10] 34.3 [10.05] 4.0
40.4 [11.84] 32.3 [9.47] 3.9
46.3 [13.57] 26.3 [7.71] 4.2 44.8 [13.13] 25.7 [7.53] 4.3
45.2 [13.25] 24.8 [7.27] 4.1 43.7 [12.81] 24.2 [7.09] 4.3
43.2 [12.66] 33.5 [9.82] 4.2 41.6 [12.19] 32.9 [9.64] 4.3
42.2 [12.37] 31.7 [9.29] 4.1 40.7 [11.93] 31.1 [9.11] 4.3
41.2 [12.07] 29.8 [8.73] 4.1 39.8 [11.66] 29.3 [8.59] 4.2
41.3 [12.10] 35.8 [10.49] 4.2 39.7 [11.63] 35.3 [10.35] 4.3
40.4 [11.84] 33.9 [9.94] 4.1 38.9 [11.40] 33.3 [9.76] 4.3
39.5 [11.58] 31.9 [9.35] 4.1 38.0 [11.14] 31.4 [9.20] 4.2
Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb
1580 [746] .19
47.3 [13.86] 27.8 [8.15] 4.2 45.8 [13.42] 27.2 [7.97] 4.4
Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RQNA-042 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C]
0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10]
Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power
1580 [746]
60°F [15.5°C] 1400 [661]
16.0 [4.69] 2.2 18.0 [5.28] 2.3 20.3 [5.95] 2.3 22.9 [6.71] 2.4 25.6 [7.50] 2.4 28.5 [8.35] 2.5 31.4 [9.20] 2.5 34.2 [10.02] 2.6 37.0 [10.84] 2.6 39.5 [11.58] 2.7 41.8 [12.25] 2.7
15.8 [4.63] 2.2 17.8 [5.22] 2.3 20.1 [5.89] 2.4 22.7 [6.65] 2.4 25.4 [7.44] 2.5 28.2 [8.26] 2.5 31.1 [9.11] 2.6 33.9 [9.94] 2.6 36.6 [10.73] 2.7 39.2 [11.49] 2.7 41.5 [12.16] 2.8
1220 [576]
1580 [746]
15.7 [4.60] 14.4 [4.22] 2.3 2.5 17.7 [5.19] 16.4 [4.81] 2.3 2.6 20.0 [5.86] 18.7 [5.48] 2.4 2.6 22.5 [6.59] 21.3 [6.24] 2.4 2.7 25.2 [7.39] 24.1 [7.06] 2.5 2.7 28.0 [8.21] 26.9 [7.88] 2.6 2.8 30.8 [9.03] 29.8 [8.73] 2.6 2.8 33.6 [9.85] 32.6 [9.55] 2.7 2.9 36.3 [10.64] 35.4 [10.37] 2.7 2.9 38.8 [11.37] 38.0 [11.14] 2.8 3.0 41.1 [12.05] 40.3 [11.81] 2.8 3.0
IDB—Indoor air dry bulb
70°F [21.1°C] 1400 [661]
1220 [576]
1580 [746]
80°F [26.7°C] 1400 [661]
1220 [576]
14.3 [4.19] 2.6 16.3 [4.78] 2.6 18.6 [5.45] 2.7 21.1 [6.18] 2.7 23.8 [6.98] 2.8 26.7 [7.83] 2.8 29.5 [8.65] 2.9 32.4 [9.50] 2.9 35.1 [10.29] 3.0 37.6 [11.02] 3.0 39.9 [11.69] 3.1
14.2 [4.16] 2.6 16.1 [4.72] 2.7 18.4 [5.39] 2.7 20.9 [6.13] 2.8 23.6 [6.92] 2.8 26.4 [7.74] 2.9 29.3 [8.59] 2.9 32.1 [9.41] 3.0 34.8 [10.20] 3.0 37.3 [10.93] 3.1 39.6 [11.61] 3.1
13.4 [3.93] 2.8 15.4 [4.51] 2.9 17.7 [5.19] 2.9 20.3 [5.95] 3.0 23.0 [6.74] 3.0 25.9 [7.59] 3.1 28.8 [8.44] 3.1 31.6 [9.26] 3.2 34.4 [10.08] 3.3 36.9 [10.81] 3.3 39.2 [11.49] 3.4
13.3 [3.90] 2.9 15.2 [4.45] 2.9 17.6 [5.16] 3.0 20.1 [5.89] 3.0 22.8 [6.68] 3.1 25.7 [7.53] 3.1 28.5 [8.35] 3.2 31.3 [9.17] 3.3 34.1 [9.99] 3.3 36.6 [10.73] 3.4 38.9 [11.40] 3.4
13.1 [3.84] 2.9 15.1 [4.43] 3.0 17.4 [5.10] 3.0 19.9 [5.83] 3.1 22.6 [6.62] 3.1 25.4 [7.44] 3.2 28.3 [8.29] 3.2 31.1 [9.11] 3.3 33.8 [9.91] 3.4 36.3 [10.64] 3.4 38.5 [11.28] 3.5
[ ] Designates Metric Conversions
13
SYSTEMS PERFORMANCE—RQNA- SERIES COOLING PERFORMANCE DATA—RQNA-048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀
O U T D O O R D R Y B U L B T E M P E R A T U R E
71°F [21.7°C] 1600 [755] .16
1400 [661] .11
1800 [850] .19
67°F [19.4°C] 1600 [755] .16
1400 [661] .11
1800 [850] .19
63°F [17.2°C] 1600 [755] .16
1400 [661] .11
Total BTUH [kW] 61.3 [17.97] 75 Sens BTUH [kW] 36.1 [10.58] [23.9] 3.4 Power
60.0 [17.58] 34.1 [9.99] 3.3
58.6 [17.17] 32.1 [9.41] 3.3
57.1 [16.73] 42.7 [12.51] 3.3
55.9 [16.38] 40.3 [11.81] 3.3
54.6 [16.00] 38.0 [11.14] 3.2
54.2 [15.88] 44.8 [13.13] 3.3
53.0 [15.53] 42.3 [12.40] 3.2
51.8 [15.18] 39.9 [11.69] 3.2
Total BTUH [kW] 60.0 [17.58] 80 Sens BTUH [kW] 35.7 [10.46] [26.7] 3.5 Power
58.7 [17.20] 33.7 [9.88] 3.5
57.3 [16.79] 31.7 [9.29] 3.5
55.8 [16.35] 42.2 [12.37] 3.5
54.6 [16.00] 39.9 [11.69] 3.4
53.3 [15.62] 37.6 [11.02] 3.4
52.9 [15.50] 44.4 [13.01] 3.5
51.7 [15.15] 41.9 [12.28] 3.4
50.5 [14.80] 39.5 [11.58] 3.4
Total BTUH [kW] 58.5 [17.14] 85 Sens BTUH [kW] 35.0 [10.26] [29.4] 3.7 Power
57.2 [16.76] 33.0 [9.67] 3.7
55.9 [16.38] 31.1 [9.11] 3.6
54.3 [15.91] 41.5 [12.16] 3.7
53.1 [15.56] 39.3 [11.52] 3.6
51.9 [15.21] 37.0 [10.84] 3.6
51.4 [15.06] 43.7 [12.81] 3.6
50.3 [14.74] 41.2 [12.07] 3.6
49.1 [14.39] 38.8 [11.37] 3.6
Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power
56.9 [16.68] 34.1 [9.99] 3.9
55.7 [16.32] 32.2 [9.44] 3.9
54.4 [15.94] 30.3 [8.88] 3.8
52.7 [15.44] 40.7 [11.93] 3.8
51.6 [15.12] 38.4 [11.25] 3.8
50.4 [14.77] 36.2 [10.61] 3.7
49.8 [14.59] 42.8 [12.54] 3.8
48.7 [14.27] 40.4 [11.84] 3.8
47.6 [13.95] 38.1 [11.17] 3.7
55.4 [16.24] 33.2 [9.73] 4.1
54.1 [15.86] 31.3 [9.17] 4.0
52.9 [15.50] 29.5 [8.65] 4.0
51.2 [15.01] 39.7 [11.63] 4.0
50.0 [14.65] 37.5 [10.99] 4.0
48.9 [14.33] 35.3 [10.35] 3.9
48.3 [14.16] 41.8 [12.25] 4.0
47.2 [13.83] 39.5 [11.58] 3.9
46.1 [13.51] 37.2 [10.90] 3.9
53.9 [15.80] 32.2 [9.44] 4.2
52.7 [15.44] 30.4 [8.91] 4.2
51.5 [15.09] 28.7 [8.41] 4.2
49.7 [14.57] 38.8 [11.37] 4.2
48.6 [14.24] 36.6 [10.73] 4.1
47.5 [13.92] 34.5 [10.11] 4.1
46.8 [13.72] 40.9 [11.99] 4.2
45.7 [13.39] 38.6 [11.31] 4.1
44.7 [13.10] 36.4 [10.67] 4.1
Total BTUH [kW] 52.5 [15.39] 105 Sens BTUH [kW] 31.4 [9.20] [40.6] 4.4 Power
51.3 [15.03] 29.6 [8.67] 4.4
50.2 [14.71] 27.9 [8.18] 4.3
48.3 [14.16] 37.9 [11.11] 4.4
47.2 [13.83] 35.8 [10.49] 4.3
46.2 [13.54] 33.7 [9.88] 4.3
45.4 [13.31] 40.0 [11.72] 4.3
44.4 [13.01] 37.8 [11.08] 4.3
43.4 [12.72] 35.6 [10.43] 4.2
50.2 [14.71] 29.0 [8.50] 4.5 49.3 [14.45] 28.7 [8.41] 4.7
49.1 [14.39] 27.3 [8.00] 4.5 48.2 [14.13] 27.0 [7.91] 4.7
47.2 [13.83] 37.3 [10.93] 4.5 46.3 [13.57] 36.9 [10.81] 4.7
46.1 [13.51] 35.2 [10.32] 4.5 45.2 [13.25] 34.9 [10.23] 4.7
45.1 [13.22] 33.2 [9.73] 4.4 44.2 [12.95] 32.8 [9.61] 4.6
44.3 [12.98] 39.4 [11.55] 4.5 43.4 [12.72] 39.0 [11.43] 4.7
43.3 [12.69] 37.2 [10.90] 4.5 42.4 [12.43] 36.9 [10.81] 4.6
42.3 [12.40] 35.0 [10.26] 4.4 41.4 [12.13] 34.7 [10.17] 4.6
Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb
1800 [850] .19
51.3 [15.03] 30.7 [9.00] 4.6 50.5 [14.80] 30.3 [8.88] 4.8
Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RQNA-048 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C]
0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10]
Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power
1800 [850]
60°F [15.5°C] 1600 [755]
1400 [661]
1800 [850]
70°F [21.1°C] 1600 [755]
1400 [661]
1800 [850]
80°F [26.7°C] 1600 [755]
1400 [661]
15.1 [4.43] 2.6 18.3 [5.36] 2.6 21.8 [6.39] 2.7 25.5 [7.47] 2.7 29.3 [8.59] 2.8 33.0 [9.67] 2.9 36.6 [10.73] 2.9 39.8 [11.66] 3.0 42.7 [12.51] 3.0 45.0 [13.19] 3.1 46.5 [13.63] 3.2
14.9 [4.37] 2.6 18.1 [5.30] 2.7 21.6 [6.33] 2.7 25.3 [7.41] 2.8 29.0 [8.50] 2.8 32.7 [9.58] 2.9 36.3 [10.64] 3.0 39.5 [11.58] 3.0 42.3 [12.40] 3.1 44.6 [13.07] 3.2 46.1 [13.51] 3.2
14.8 [4.34] 2.6 17.9 [5.25] 2.7 21.4 [6.27] 2.8 25.0 [7.33] 2.8 28.8 [8.44] 2.9 32.4 [9.50] 3.0 35.9 [10.52] 3.0 39.1 [11.46] 3.1 41.9 [12.28] 3.1 44.2 [12.95] 3.2 45.7 [13.39] 3.3
14.3 [4.19] 3.0 17.5 [5.13] 3.1 21.0 [6.15] 3.1 24.7 [7.24] 3.2 28.5 [8.35] 3.3 32.3 [9.47] 3.3 35.8 [10.49] 3.4 39.1 [11.46] 3.5 41.9 [12.28] 3.5 44.2 [12.95] 3.6 45.8 [13.42] 3.6
14.2 [4.16] 3.1 17.3 [5.07] 3.1 20.8 [6.10] 3.2 24.5 [7.18] 3.3 28.3 [8.29] 3.3 32.0 [9.38] 3.4 35.5 [10.40] 3.4 38.7 [11.34] 3.5 41.5 [12.16] 3.6 43.8 [12.84] 3.6 45.4 [13.31] 3.7
14.1 [4.13] 3.1 17.2 [5.04] 3.2 20.6 [6.04] 3.2 24.3 [7.12] 3.3 28.0 [8.21] 3.4 31.7 [9.29] 3.4 35.2 [10.32] 3.5 38.4 [11.25] 3.6 41.2 [12.07] 3.6 43.4 [12.72] 3.7 45.0 [13.19] 3.8
13.4 [3.93] 3.4 16.6 [4.86] 3.4 20.1 [5.89] 3.5 23.9 [7.00] 3.5 27.6 [8.09] 3.6 31.4 [9.20] 3.7 34.9 [10.23] 3.7 38.2 [11.20] 3.8 41.0 [12.02] 3.9 43.3 [12.69] 3.9 44.9 [13.16] 4.0
13.3 [3.90] 3.4 16.5 [4.84] 3.5 20.0 [5.86] 3.5 23.6 [6.92] 3.6 27.4 [8.03] 3.7 31.1 [9.11] 3.7 34.6 [10.14] 3.8 37.9 [11.11] 3.9 40.7 [11.93] 3.9 42.9 [12.57] 4.0 44.5 [13.04] 4.0
13.2 [3.87] 3.5 16.3 [4.78] 3.5 19.8 [5.80] 3.6 23.4 [6.86] 3.7 27.2 [7.97] 3.7 30.8 [9.03] 3.8 34.3 [10.05] 3.8 37.5 [10.99] 3.9 40.3 [11.81] 4.0 42.5 [12.46] 4.0 44.1 [12.92] 4.1
IDB—Indoor air dry bulb
[ ] Designates Metric Conversions
14
15
1350 CFM/1700 CFM [496/802 L/s]
1225 CFM/1575 CFM [578/743 L/s]
1050 CFM/1350 CFM [496/637 L/s]
875 CFM/1125 CFM [413/531 L/s]
700 CFM/900 CFM [271/319 L/s]
Manufacturer Recommended Air-Flow Range (Min/Max) CFM
10x9 3/4 HP [559] 2 Speed Motor
10x9 3/4 HP [559] 2 Speed Motor
10x9 1/3 HP [248] 1 Speed Motor
10x9 1/2 HP [372] 2 Speed Motor
9x7 1/4 HP [186] 2 Speed Motor
Blower Size/ Motor HP [W] & # of Speeds
[ ] Designates Metric Conversions
NOTE: Effect of electric heat strip on airflow performance is negligible.
Low
Low
3.0 [10.55]
4.0 [14.07]
Low
2.5 [8.79]
Low
High
2.0 [7.03]
3.5 [12.31]
Motor Speed from Factory
Nominal Cooling Capacity Tons [kW]
High
Low
High
Low
High
High
Medium
Low
High
Low
Motor Speed
292 1076 [508]
CFM
1514 [715] 895 538
CFM RPM Watts
966 454
RPM Watts
1770 [835]
1675 [791]
CFM
CFM
321
390
870
RPM Watts 923
1559 [736]
CFM
RPM
268
Watts
824
RPM
1455 [687]
CFM Watts
352
355
466
989
1751 [826]
401
944
1658 [782]
327
893
1530 [722]
280
856
1431 [675]
805
785
RPM
1201 [567]
514
930
1461 [690]
415
810
1197 [565]
349
775
1059 [500]
278
965
861 [406]
214
785
657 [310]
0.2 [.05]
473
1018
1706 [805]
412
979
1610 [760]
338
932
1488 [702]
288
889
1396 [659]
346
830
1173 [554]
493
965
1415 [668]
407
855
1179 [556]
341
820
1032 [487]
266
995
822 [388]
203
870
634 [299]
0.3 [.07]
486
1050
1672 [789]
425
1013
1580 [746]
351
968
1454 [686]
303
931
1360 [642]
340
870
1137 [537]
473
985
1370 [647]
397
890
1162 [548]
331
865
996 [470]
253
1020
777 [367]
191
905
602 [284]
0.4 [.10]
490
1078
1624 [766]
433
1045
1535 [724]
364
1007
1417 [669]
311
968
1315 [621]
331
905
1090 [514]
454
1005
1322 [624]
386
920
1137 [537]
320
905
950 [448]
239
1045
721 [340]
171
940
560 [264]
0.5 [.12]
External Static Pressure—Inches W.C. [kPa]
481
1100
1555 [734]
440
1077
1491 [704]
371
1036
1375 [649]
325
1009
1285 [606]
320
950
1030 [486]
434
1025
1266 [597]
370
960
1097 [518]
305
940
896 [423]
221
1070
651 [307]
163
980
505 [238]
0.6 [.15]
CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil
Watts
1222 [577]
423
CFM
765
RPM
1222 [577]
Watts
CFM
356
940
RPM Watts 730
898 [424]
CFM
RPM
221
Watts
695
RPM
675 [319]
0.1 [.02]
Watts
CFM
INDOOR AIRFLOW PERFORMANCE—208 VOLTS 0.7 [.17]
460
1115
1463 [690]
432
1098
1422 [671]
381
1072
1336 [631]
331
1041
1241 [586]
306
990
954 [450]
412
1045
1197 [565]
351
995
1033 [488]
287
975
832 [393]
199
1090
562 [265]
149
1020
435 [205]
AIRFLOW PERFORMANCE—RQNA- SERIES
16
1350 CFM/1700 CFM [496/802 L/s]
1225 CFM/1575 CFM [578/743 L/s]
1050 CFM/1350 CFM [496/637 L/s]
875 CFM/1125 CFM [413/531 L/s]
700 CFM/900 CFM [271/319 L/s]
Manufacturer Recommended Air-Flow Range (Min/Max) CFM
10x9 3/4 HP [559] 2 Speed Motor
10x9 3/4 HP [559] 2 Speed Motor
10x9 1/3 HP [249] 1 Speed Motor
10x9 1/2 HP [373] 2 Speed Motor
9x7 1/4 HP [186] 2 Speed Motor
Blower Size/ Motor HP [W] & # of Speeds
High
Low
High
Low
High
High
Medium
Low
High
Low
Motor Speed
[ ] Designates Metric Conversions
DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] Pressure Drop—Inches W.C. [kPa] .00 .01 [.002]
NOTE: Effect of electric heat strip on airflow performance is negligible.
Low
High
3.0 [10.55]
4.0 [14.07]
Low
2.5 [8.79]
Low
High
2.0 [7.03]
3.5 [12.31]
Motor Speed from Factory
Nominal Cooling Capacity Tons [kW]
315 1206 [569]
CFM
1641 [774] 980 589
CFM RPM Watts
440
1000 [472] .02 [.005]
955
RPM Watts
1748 [825]
1692 [799]
CFM
CFM
317
404
867
RPM Watts 931
1550 [732]
CFM
RPM
276
Watts
831
RPM
1467 [692]
CFM Watts
419
428
1200 [566] .03 [.007]
446
978
1718 [811]
409
950
1661 [784]
323
890
1520 [717]
282
854
1439 [679]
875
835
RPM
1357 [640]
565
1000
1577 [744]
498
900
1368 [646]
406
815
1182 [558]
303
1015
922 [435]
242
870
751 [354]
0.2 [.05]
1400 [661] .05 [.012]
462
1010
1686 [796]
424
982
1633 [771]
339
930
1486 [701]
297
894
1408 [665]
406
915
1312 [619]
543
1020
1515 [715]
481
935
1327 [626]
394
870
1157 [546]
288
1035
882 [416]
230
910
725 [342]
0.3 [.07]
1600 [775] .07 [.017]
475
1043
1647 [777]
434
1018
1589 [750]
355
974
1449 [684]
307
932
1360 [642]
392
940
1258 [594]
523
1035
1455 [687]
464
970
1285 [606]
381
910
1128 [532]
273
1055
830 [392]
217
950
691 [326]
0.4 [.10]
484
1073
1616 [763]
450
1054
1560 [736]
362
1003
1407 [664]
319
972
1331 [628]
378
965
1201 [567]
503
1050
1393 [657]
447
1000
1238 [584]
368
950
1091 [515]
257
1070
769 [363]
204
985
645 [304]
0.5 [.12]
External Static Pressure—Inches W.C. [kPa]
473
1096
1543 [728]
453
1082
1512 [714]
377
1039
1382 [652]
326
1005
1287 [607]
365
985
1145 [540]
481
1065
1329 [627]
431
1020
1183 [558]
353
975
1044 [493]
241
1085
701 [331]
189
1010
584 [276]
0.6 [.15]
CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil
Watts
1391 [656]
498
CFM
865
RPM
1411 [666]
Watts
CFM
419
990
RPM Watts 760
946 [446]
CFM
RPM
253
Watts
825
RPM
771 [364]
0.1 [.02]
Watts
CFM
INDOOR AIRFLOW PERFORMANCE—230 VOLTS 0.7 [.17]
459
1111
1472 [695]
443
1103
1442 [681]
385
1073
1337 [631]
341
1042
1259 [594]
355
1000
1093 [516]
456
1080
1262 [596]
391
1035
1116 [527]
334
1000
983 [464]
226
1100
630 [297]
181
1030
546 [258]
AIRFLOW PERFORMANCE—RQNA- SERIES
ELECTRICAL DATA—RQNA- SERIES
Evaporator Fan
Condenser Motor
Compressor Motor
Unit Information
ELECTRICAL DATA – RQNA- SERIES -024JK
-030JK
-036CK
-036JK
-042CK
-042JK
-048CK
-048JK
Unit Operating Voltage Range
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
Minimum Circuit Ampacity
17/17
21/21
16/16
24/24
25/25
32/32
25/25
37/37
20/20
25/25
20/20
30/30
30/30
40/40
30/30
45/45
25/25
30/30
25/25
35/35
35/35
45/45
35/35
50/50
1 208/230 1 2 3450 10.9/10.9 54/54 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/4 1.5 2.4
1 208/230 1 2 1/2 3450 13.5/13.5 72.5/72.5 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/2 2.4 5.1
1 200/230 3 3 3450 10.3/10.3 77/77 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/3 1.7 2.5
1 208/230 1 3 3450 16/16 88/88 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/3 1.7 2.5
1 200/230 3 3 1/2 3450 12.4/12.4 88/88 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6.8 0
1 208/230 1 3 1/2 3450 17.9/17.9 95/95 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6.8 0
1 200/230 3 4 3450 12.4/12.4 88/88 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6.8 0
1 208/230 1 4 3450 22/22 137/137 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6.8 0
Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No. Volts Phase HP RPM Amps (RLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA)
1. Horsepower Per Compressor. 2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.
17
ELECTRIC HEATER KITS—RQNA- SERIES Unit Model Application
Electric Heater Kit Models RXQJ-A05J (208-240 volt, 1-ph, 5kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RQNA-024JK
RXQJ-A05J (208-240 volt, 1-ph, 5kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW) RXQJ-A15J (208-240 volt, 1-ph, 15kW)
RQNA-030JK RQNA-036JK
RXQJ-B10J (208-240 volt, 1-ph, 10kW)
RQNA-042JK
RXQJ-B15J (208-240 volt, 1-ph, 15kW) RXQJ-B10J (208-240 volt, 1-ph, 10kW) RXQJ-B15J (208-240 volt, 1-ph, 15kW) RXQJ-A10C (208-240 volt, 3-ph, 10kW) RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RQNA-048JK
RQNA-036CK
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RQNA-042CK
RXQJ-A15C (208-240 volt, 3-ph, 15kW) RXQJ-A10C (208-240 volt, 3-ph, 10kW) RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RQNA-048CK
WARNING ONLY ELECTRIC HEATER KITS SUPPLIED BY THIS MANUFACTURER AS DESCRIBED IN THIS PUBLICATION HAVE BEEN DESIGNED, TESTED, AND EVALUATED BY A NATIONALLY RECOGNIZED SAFETY TESTING AGENCY FOR USE WITH THIS UNIT. USE OF ANY OTHER MANUFACTURED ELECTRIC HEATERS INSTALLED WITHIN THIS UNIT MAY CAUSE HAZARDOUS CONDITIONS RESULTING IN PROPERTY DAMAGE, FIRE, BODILY INJURY OR DEATH.
18
19
048CK
042CK
036CK
Unit Model No. RQNA-
048JK
042JK
036JK
030JK
024JK
Unit Model No. RQNA-
No Heat A10C A15C No Heat A10C A15C No Heat A10C A15C
— 1 2 — 1 2 — 2 2 — 2 2 — 2 2
No. of Sequence Steps — 3.6/4.8 7.2/9.6 — 3.6/4.8 7.2/9.6 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13
24.56/32.75 36.84/49.13
24.56/32.75 36.84/49.13
12.28/16.38 24.56/32.75
— 12.28/16.38 24.56/32.75
— 17.3/20.0 34.6/40.0 — 17.3/20.0 34.6/40.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0
Rated Heater Heater Heater kW KBTU/Hr Amp. @ 208-240 V @ 208-240 V @ 208-240 V 17/17 39/42 60/67 21/21 43/46 64/71 24/24 67/74 88/99 31/31 74/81 96/106 36/36 79/86 101/111
Unit Min. Ckt. Ampacity @ 208-240 V Min./Max. @ 208 V 20/25 40/40 60/60 25/30 45/50 70/70 30/35 70/70 90/90 35/45 80/80 100/100 45/50 80/90 110/110
Min./Max. @ 240 V 20/25 45/45 70/70 25/30 50/50 80/80 30/35 80/80 100/100 35/45 90/90 110/110 45/50 90/90 125/125
Over Current Protective Device Size
Heat Pump
— 22/25 44/50 — 22/25 44/50 — 44/50 65/75 — 44/50 65/75 — 44/50 65/75
Min. Ckt. Ampacity 208/240V — 25/25 45/50 — 25/25 45/50 — 45/50 70/80 — 45/50 70/80 — 45/50 70/80
Max. Fuse Size 208/240V
Heater Kit
17/17 — — 21/21 — — 24/24 — — 31/31 — — 36/36 — —
Min. Circuit Ampacity 208-240 V Min./Max. @ 208 V 20/25 — — 25/30 — — 30/35 — — 35/45 — — 45/50 — —
— 3 3 — 3 3 — 3 3
— 3 3 — 3 3 — 3 3
No. of Sequence Steps — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13
24.56/32.75 36.84/49.13
24.56/32.75 36.84/49.13
— 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7
Heater Heater Rated KBTU/Hr Amp. Heater kW @ 208-240 V @ 208-240 V @ 208-240 V
Heater Kit
16/16 41/45 54/60 24/24 49/53 62/67 26/26 51/55 63/69
Unit Min. Ckt. Ampacity @ 208-240 V
Single Power Supply For Both Unit and Heater Kit
Min./Max. @ 208 V 20/25 45/45 60/60 30/35 50/50 70/70 30/35 60/60 70/70
Min./Max. @ 240 V 20/25 45/45 60/60 30/35 60/60 70/70 30/35 60/60 70/70
Over Current Protective Device Size
Heat Pump
— 25/29 38/44 — 25/29 38/44 — 25/29 38/44
Min. Ckt. Ampacity 208/240V
— 25/30 40/45 — 25/30 40/45 — 25/30 40/45
Max. Fuse Size 208/240V
Heater Kit
16/16 — — 24/24 — — 26/26 — —
Min. Circuit Ampacity 208-240 V
Min./Max. @ 208 V 20/25 — — 30/35 — — 30/35 — —
Min./Max. @ 240 V 20/25 — — 30/35 — — 30/35 — —
Over Current Protective Device Size
Heat Pump
Separate Power Supply For Both Unit and Heater Kit
Min./Max. @ 240 V 20/25 — — 25/30 — — 30/35 — — 35/45 — — 45/50 — —
Over Current Protective Device Size
Heat Pump
Separate Power Supply For Both Unit and Heater Kit
208-240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION
— 1 2 — 1 2 — 2 3 — 2 3 — 2 3
RXQJNo. of Heater Kit Elements Nominal kW
No Heat A05J A10J No Heat A05J A10J No Heat A10J A15J No Heat B10J B15J No Heat B10J B15J
RXQJNo. of Heater Kit Elements Nominal kW
Heater Kit
Single Power Supply For Both Unit and Heater Kit
208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION
ELECTRIC HEATER KITS—RQNA- SERIES
UNIT DIMENSIONS—RQNA- SERIES UNIT DIMENSIONS SELF-CONTAINED AIR CONDITIONERS
OUTDOOR FAN GRILLE AND COMPRESSOR ACCESS
CONTROL ACCESS PANEL
FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY)
LIQUID PRESSURE SERVICE PORT
OUTDOOR COIL PROTECTIVE GRILLE
30% 2%
SUCTION PRESSURE SERVICE PORT
21% 2%
THREADED PVC CONDENSATE DRAIN CONNECTION (3/4" [19.05 mm] N.P.T.) THERMOSTAT WIRING ENTRANCE
29% 2%
ELECTRICAL POWER ENTRANCE
CORNER WEIGHTS % OF TOTAL UNIT WEIGHT
20% 2%
SIDE RETURN DUCT OPENING BLOWER/ EVAPORATOR ACCESS PANEL
TOP VIEW
SIDE SUPPLY DUCT OPENING
BOTTOM VIEW 451/16" [1145 mm] INSIDE
4719/32" [1209 mm]
13/16" [30 mm] TYP.
11/2" [38 mm] TYP.
BOTTOM RETURN DUCT OPENING 5013/16" [1290 mm]
497/16" [1256 mm] INSIDE
BOTTOM SUPPLY DUCT OPENING
141/4" [362 mm] TYP.
199/16" [497 mm]
OUTDOOR FAN GRILLE & COMPRESSOR ACCESS
313/16" [97 mm]
[ ] Designates Metric Conversions
20
45/16" [95 mm]
153/8" [391 mm]
33/16" [97 mm]
UNIT DIMENSIONS—RQNA- SERIES SIDE VIEW
SIDE VIEW OUTDOOR COIL PROTECTIVE GRILLE
FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY)
THERMOSTAT WIRE ENTRANCE
11/8" [28.6 mm]
255/16" [643 mm]
103/16" [259 mm] 51/16" [129 mm]
43/4" [121 mm]
ELECTRICAL POWER ENTRANCE
527/16" [1332 mm]
BLOWER/ EVAPORATOR ACCESS PANEL
BACK VIEW
FRONT VIEW
CONTROL ACCESS PANEL 47/8" [124 mm]
SIDE SUPPLY DUCT OPENING
LIQUID PRESSURE SERVICE PORT
133/4" [349 mm]
75/16" [186 mm]
57/16" [138 mm] 81/2" [216 mm] TYP.
2211/16" [576 mm]
47/16" [113 mm]
471/2" [1207 mm]
THREADED PVC CONDENSATED DRAIN CONNECTION (3/4 N.P.T.)
15" [381 mm]
143/16" [360 mm] TYP. 191/8" [486 mm]
SHOWN WITH DUCT COVERS REMOVED. SUCTION PRESSURE SERVICE PORT
IMPORTANT: INSTALLATION MUST NOT INTERFERE WITH DRAINAGE OPENINGS IN BOTTOM OF UNIT UNDER OUTDOOR COIL.
Model Number
Height “A”
024
3515/16
030, 036, 042, 048
41
[ ] Designates Metric Conversions
21
IMPORTANT: UNIT MUST BE LEVEL TO PREVENT WATER MIGRATION.
SIDE RETURN DUCT OPENING
TYPICAL INSTALLATIONS
[ ] Designates Metric Conversions
22
ACCESSORIES ACCESSORY EQUIPMENT Accessory Description
Model Application RQNA-
Thermostats
Accessory Model No. See Thermostat Specification Sheet (T22-001) RXQG-AAA14 (14" [356 mm] Height) RXQG-AAA24 (24" [610 mm] Height) RXRN-D15 RXRE-CAA30 (3 Position) RXRD-CAM10 (Fully Modulating)
Roofcurbs
RQNA-
Supply & Return Diffusers
RQNA-
Economizers (Downflow Only)
RQNA-
Economizers (Sideflow Only)
RQNA-
RXRD-CCM10 (Fully Modulating) RXRE-CAA30 (3 Position)
Fresh Air Damper
RQNA-
RXRF-FAB1 (Motorized-35%) RXRF-FAA1 (Fixed-35%)
Rectangular to Round Transition (Downflow)
RQNA-
Filter Kit High Pressure Control
RQNARQNA-
RXMC-CA02 (16" [406 mm] Ducts) RXMC-CA03 (18" [457 mm] Ducts) RXRY-01 RXAB-A04
Outdoor Thermostat
RQNA-
RXPT-A01
Low Ambient Control Duct Adapter Sideflow Square to Round Transition
RQNARQNA-
RXPZ-C01 or RXPZ-F01 RXMC-A01
COMMON SUPPLY/RETURN CONCENTRIC AIR DIFFUSER
SUPPLY/RETURN DIFFUSER
NOTE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed with a greater distance than recommended above, the supply air may become stratified above the required comfort area causing uncomfortable conditions.
AIRFLOW/PRESSURE DROP INFORMATION (INCHES W.C. [kPa]) Designed to convert a side by side or an over and under arrangement into a concentric distribution of air. The diffuser is flush mounted, completely insulated, assembled, and internally baffled to provide four way supply air distribution with a center return. To make the assembly complete and ready to fit into a 2' [0.61 m] x 4' [1.22 m] suspended ceiling grid, the diffuser includes adjustable supply louvers, hanging rings, anti-sweat gasket, and round flanges for use with flexible ducts.
Approximate CFM [L/s]-Supply Air 1300 [614] 1575 [743] 1800 [850] 2200 [1038] Plenum & Supply/Return Duct .07 [.017] .10 [.024] .12 [.030] .17 [.042] Diffuser .09 [.022] .13 [.032] .16 [.040] .24 [.060] Economizer .06 [.015] .09 [.022] .11 [.027] .17 [.042] Accessory
SUPPLY AIR/PERFORMANCE Model No. RXRNBD15
Diameter Inches [mm] 16 [406]
Shipping Wt. Lbs. [kg] 90 [40.82]
Diffuser Airflow CFM [L/s] 800 [378]-1200 [566] 1600 [755]-2000 [944]
Dimension A Inches [mm] 201/2 [521]
Range of Throw Ft. [m] 14 [4.27]-16 [4.88] 18 [5.49]-28 [8.53] [ ] Designates Metric Conversions
23
ACCESSORIES
24
ACCESSORIES DUCT ADAPTERS RECTANGULAR TO ROUND TRANSITIONS (DOWNFLOW)
RXMC-CA02
RXMC-CA03
[ ] Designates Metric Conversions
25
ACCESSORIES FRESH AIR DAMPER FOR USE ON RQNA- SERIES RXRF-FAA1 (Fixed - 0-35%) The 0-35% manual outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The amount of outside air (0-35%) is controlled by simply adjusting the side damper. RXRF-FAB1 (Motorized - 0-35%) The 0-35% motorized outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The control motor opens the adjustable slide damper when the unit blower motor is energized.
ECONOMIZERS RXRE-CAA30 (3 Position) and RXRD-CAM10 (Fully Modulating) for RQNA- Series RXRE-CAA30 (3 Position) Provided with enthalpy control, and mixed air sensor. Settings include fully open, fully closed and adjustable mid point. RXRD-CAM10 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position potentiometer for proportioning (modulating) the amount of fresh air.
[ ] Designates Metric Conversions
26
ACCESSORIES ECONOMIZERS RXRD-CCM10 (Fully Modulating) and RXRE-CCA30 (3 Position) Horizontal Application RXRD-CCM10 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position potentiometer for proportioning (modulating) the amount of fresh air. RXRE-CCA30 (3 Position) Has outdoor air sensor, minimum position potentiometer and mixed air sensor to provide three damper positions. [ ] Designates Metric Conversions
27
ACCESSORIES FILTER KIT INSTALLATION RXRY-01 For use in either vertical or horizontal discharge.
Minimum Airflow 510 [241] 680 [321] 850 [401] 1020 [481] 1190 [562] 1275 [602] 1700 [802]
CFM [L/s] Nominal Airflow 600 [283] 800 [378] 1000 [472] 1200 [566] 1400 [661] 1500 [708] 2000 [944]
Airflow Pressure Drop, Inches W.C. [kPa] CFM [L/s] 1" Filter 2" Filter 500 [236] .02 [.0050] .03 [.0075] 600 [283] .02 [.0050] .03 [.0075] 700 [330] .03 [.0075] .04 [.0010] 800 [378] .04 [.0010] .05 [.0124] 900 [425] .05 [.0124] .06 [.0149] 1000 [472] .07 [.0174] .08 [.0199] 1100 [519] .08 [.0199] .09 [.0224] 1200 [566] .10 [.0249] .12 [.0299] 1300 [614] .13 [.0324] .15 [.0373] 1400 [661] .16 [.0398] .19 [.0473] 1500 [708] .19 [.0473] .21 [.0523] 1600 [755] .20 [.0498] .23 [.0572] 1700 [802] .21 [.0523] .24 [.0598] 1800 [850] .22 [.0548] .25 [.0623] 1900 [897] .24 [.0598] .27 [.0672] 2000 [944] .26 [.0647] .29 [.0722]
Maximum Airflow 660 [311] 880 [415] 1100 [519] 1320 [623] 1540 [727] 1650 [779] 2200 [1039]
[ ] Designates Metric Conversions
28
ACCESSORIES DUCT ADAPTER SIDEFLOW SQUARE TO ROUND TRANSITION RXMC-BA01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation.
29
ACCESSORIES Roofcurb (Sloped)
RXQG-AAA14 (14" [356 mm] High)
RXQG-AAA14 & RXQG-AAA24 for RQNA- Series Heat pump models must use sloped curbs. Hinged corners make for fast, easy set-up.
RXQG-AAA24 (24" [610 mm] High)
Packaged Heat Pump Roofcurb Installation (Sloped) OUTDOOR FAN GRILLE AND COMPRESSOR ACCESS
OUTDOOR COIL PROTECTIVE GRILLE
5" [127 mm]
IMPORTANT: UNIT MUST BE LEVEL TO PREVENT WATER MIGRATION
LIQUID PRESSURE SERVICE PORT SUCTION PRESSURE SERVICE PORT
207/8" [530.2 mm]
THREADED PVC CONDENSATE DRAIN CONNECTION (3/4" [19.05 mm] N.P.T.)
CONTROL ACCESS PANEL
[ ] Designates Metric Conversions
30
ACCESSORIES ROOFCURB ADAPTERS Fabricated from galvanized steel to adapt the New cabinet to the old style curb. All are furnished with a New gasket. OLD MODEL PACKAGE HEAT PUMP
OLD CURB MODEL
SMALL CABINET (11/2-2 TON) [5.28-7.03 kW] RPNCRPND-
20 SERIES
RXPA-CA20
MEDIUM CABINET (21/2-3 TON) [8.79-10.55 kW] RPNCRPND-
21 SERIES
RXPA-CA21
EXTRA LARGE CABINET (31/2-5 TON) [12.31-17.58 kW] RPNCRPND-
23 SERIES
RXPA-CA23
NEW MODEL TO OLD MODEL ROOFCURB ADAPTER
NEW MODEL PACKAGE HEAT PUMP
ONLY 1 CABINET SIZE— ALL MODELS RXPX-BACCA20 RXPX-BACCA21 RXPX-BCCCA23
(1) SLOPE TYPE (2) FULL PERIMETER TYPE [ ] Designates Metric Conversions
31
RQNA-
WIRING SCHEMATICS—RQNA- SERIES
32
WIRING SCHEMATICS—RQNA- SERIES
33
WIRING SCHEMATICS—RQNA- SERIES
34
WIRING SCHEMATICS—RQNA- SERIES
35
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
*Electric Heating Elements for Optional Electric Heating Kits ..................................Five (5) Years *Compressor.................................................Five (5) Years Any Other Part 1-Phase Models ............................................Five (5) Years 3-Phase Models ..............................................One (1) Year
RUUD AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.” PRINTED IN U.S.A.
10-07 DC
FORM NO. P22-764 REV. 4 Supersedes Form N o . P 2 2 - 7 6 4 R e v. 3