91-00-01-01
Section J — Analytical Instruments
Contents
Product Type
Literature No.
Overview 183
Chromatograph SGC 3000 Model SGC 302 Smart Gas Chromatograph
184
70-82-02-01
34-GC-03-01
pH 9782 pH/ORP Multifunction Analyzer/Controller Specification
70-82-03-23
7079 pH/ORP Transmitter Specification
70-82-03-08
7084 Microprocessor pH/ORP Analyzer/Controller Specification
70-82-03-02
7096 pH/ORP Analyzer/Controller Specification
70-82-03-09
7773 Multipurpose pH/ORP Electrode Mountings Specification
70-82-03-03
7758 Pipeline Electrode Mountings for Industrial pH and ORP Measurements Specification
70-82-03-04
7774 pH/ORP Electrode Insertion/Removal Assemblies Specification
70-82-03-05
7777 Durafet and Meredian II Combination pH/ORP Electrode Mountings Specification
70-82-03-06
7794 Sanitary Durafet pH Electrodes Specification
70-82-03-07
HPW7000 Hi-pHurity Water Measurement System Specification
70-82-03-28
Model Selection Guides
185
Series 9782 Analyzer
51-52-16-44
7079 pH/ORP Transmitter
51-52-16-38
7084 pH/ORP Analyzer/Controller
51-52-16-39
7096 pH/ORP Analyzer/Controller
51-52-16-42
Series 7773 Electrode Mounting
51-52-16-33
Series 7758 Electrode Mounting
51-52-16-29
Series 7774 Electrode Mounting
51-52-16-28
Series 7777 Electrode Mounting
51-52-16-17
Series 7794 Electrode Mounting
51-52-16-32
HPW7000 Electrode Mounting
51-52-16-46
Replacement pH/ORP, Specification Electrodes & Automatic Temperature Compensators
RE-1
Specific Ion Sodium Ion Measuring System Specification
70-82-03-10
7082 Specific Ion Monitor/Controller Specification
70-82-03-11
Model Selection Guides 7972 Sodium Ion Analyzer
51-52-16-40
Series 7082 Specific Ion Monitor/Controller
51-52-16-01
91-00-01-01
Product Type
186
Literature No.
Conductivity 9782 Conductivity/Resistivity Multifunction Analyzer/Controller Specification
70-82-03-24
7079-17 Electrolytic Conductivity Transmitter Specification
70-82-03-15
Industrial Electrolytic Conductivity Cells Specification
70-82-03-14
Model Selection Guides
187
9782 Conductivity Analyzer
51-52-16-44
7079 Conductivity Transmitter
51-52-16-37
4973 and 4974 Conductivity Cells
51-52-16-13
4905 Conductivity Cells
51-52-16-14
4909 and 4908 Conductivity Cells
51-52-16-15
4801 and 4802 Conductivity Cells
51-52-16-16
Dissolved Oxygen Series 7020 Dissolved Oxygen Analyzer/Controller Specification
70-82-03-16
7931 Series Equilibrium Dissolved Oxygen Probe Specification
70-82-03-17
Model Selection Guides
188
Series 7020 Dissolved Oxygen Analyzer
51-52-16-18
Series 7931 Dissolved Oxygen Probe
51-52-16-12
Gas Analysis 7866 Thermal Conductivity Analyzer for Binary Gas Mixtures Specification
70-82-03-18
Remote Range Indicator & 7872 Sampling System Specification
70-82-03-19
Model Selection Guides
189
7866 Thermal Conductivity Gas Analyzers
51-52-16-41
7866H Thermal Conductivity Analyzers for Hydrogen Cooled Generator Applications
51-52-16-35
7872 Sampling System
51-52-16-36
Dew Point/Relative Humidity 4111 Temperature Compensated Humidity Specification
70-82-03-20
4112 Dew Point and Temperature Transmitter Specification
70-82-03-21
4114 Dew Point and Temperature Transmitter Specification
70-82-03-22
Dewguard
31-41-03-30
Model Selection Guides 4111 Temperature Compensated Humidity Transmitter
51-52-16-22
4112 Dew Point & Temperature Transmitter
51-52-16-23
4113 Accessories for 4100 Series Dew Point/Humidity Transmitters
51-52-16-34
4114 Dew Point & Temperature Transmitter
51-52-16-24
DewGuard Portable Dew Point & Temperature Measuring System
51-52-16-25
70-82-02-01 1/99
Analytical Instruments
Overview
SGC 3000 SMART GAS CHROMATOGRAPH features quick
7777 MERIDIAN pH/ORP ELECTRODE
7096 pH/ORP ANALYZER
and reliable process gas analysis, as part of the process loop, for on-line control of industrial processes. The rugged design of the SGC 3000 enables its use in a wide variety of applications such as petroleum refining and processing of petrochemicals, chemicals, and natural gas. The SGC 3000 measures over 30 process gases including H2 to C6. It then converts concentration measurements into analog (4 to 20 mA dc) or digital signals in the field, and transmits the signals to a receiver. Model SGC302 can be handled like a transmitter. Parameters can be remotely set, adjusted, and selfdiagnosed through the Smart Field Communicator (SFC) Model STS103.
The conventional glass Meredian® pH/ORP electrodes offer a reliable combination of measurement and reference electrodes together with integral automatic temperature compensation. A selection of low- or high temperature glass is offered to ensure low sodium error, optimum durability at operating temperatures, long-term accuracy, and reliable performance. Meredian electrodes include a permanent reference junction and gel fill for maintenance-free operation. Typical applications include any pH application, from high-purity water analysis to wastewater neutralization.
7777 DURAFET pH SOLID STATE ELECTRODE is the only industrial
the widest selection of advanced features with an innovative Human Machine Interface and menu-guided display. Set-up and configuration is fast and simple. Multiple parameters—pH, ORP, and temperature, in some cases—can be viewed on one screen. Menu-driven configuration and calibration is made easy with instructional prompts and messages. Alarm conditions and diagnostic messages are displayed in text form. Advanced features include auto clean/calibration, dual electrode calibration, on/off, or CAT, DAT, and PFT control capabilities, and a security lock. Typical applications include chemicals, foods, pharmaceuticals, pulp and paper, and electric utilities industries.
non-glass, solid-state sensor based on Ion Sensitive Field Effect Transistor (ISFET) technology. The solid-state sensor makes the Durafet electrode virtually unbreakable, with an unprecedented 3-sigma response in less than one second. The Durafet‘s longer electrode life does more than lower maintenance costs--it provides increased reliability for your critical processes. Typical applications include water treatment, wastewater management, and neutralization.
7794 SANITARY DURAFET pH ELECTRODE employs durable, nonglass electrodes to perform continuous on-line pH measurement for sanitary applications. Solid-state ISFET technology eliminates the conventional, fragile glass electrode which is unacceptable for in-line measurement in many sanitary applications. The Sanitary Durafet electrodes are authorized to use a 3-A symbol and are designed to meet sanitary standards with FDA compliant materials of construction. Typical applications include processing pH measurement in food and dairy industries, fruit drinks, and tomato sauces.
9782 pH/ORP ANALYZER combines
7084 pH/ORP PID CONTROLLER is a unique full-function microprocessorbased analyzer/controller. This universal analyzer/controller provides measurement plus proportioning control—in feedback, feedforward, or adaptive configuration. Employing a superior combination of analog and digital techniques, the 7084 provides many innovations as standard features in one basic model. Typical applications include chemicals, foods, pharmaceuticals, pulp and paper, and electric utilities industries.
The 7096 microprocessor-based analyzer offers basic economical pH/ORP measurement and control. The analyzer ensures accurate and reliable pH/ORP measurements, while the 1/4-DIN, NEMA 4 front-panel design makes the analyzer ideal for OEM applications where panel space is limited. Typical applications include OEM water treatment and wastewater applications.
7079 pH/ORP TRANSMITTER is designed to meet the need for a twowire transmitter that produces a currentoutput signal proportional to a pH or ORP input, with explosion-proof features and intrinsically safe operation. Typical applications include hazardous environments in all processing industries.
9872C CONDUCTIVITY/RESISTIVITY/ CONCENTRATION ANALYZERS Honeywell’s 9782C analyzers measure conductivity, resistivity, Total Dissolved Solids (TDS) or concentration in all conventional process and ultra-pure water applications. The 9782C can measure at two locations simultaneously and provide display, alarms, and analog outputs for both. If desired, a comparison of the two measurements can be used for process control, with additional alarms or analog output on the compared value. The user friendly, menu-driven functions and keypad simplify configuration and calibration and reduce installation and wiring time. Relays and isolated output signals can be used for alarm, control, and data acquisition. Internal timers, in coordination with the relays, can be used to perform unattended cell cleaning. Typical applications include power generation, pharmaceuticals, semiconductor manufacturing, purewater treatment, process water, and industrial wastewater processes.
70-82-02-01
CONDUCTIVITY CELLS
DEWGUARD is an accurate, easy-to-
The rugged construction of Honeywell conductivity cells ensures reliable, continuous measurement of conductivity in all types of processes. Typical applications include power generation, pharmaceutical, semiconductor manufacturing, purewater treatment, process water, and industrial wastewater processes.
use, portable dew point measuring system. The DewGuard incorporates Honeywell’s 4112 Dew Point and Temperature Transmitter and a sampling system into one compact, portable package. This system has been specifically designed to meet the needs of the heattreat industry for either spot or continuous dew point measurement of generator gases or furnace atmospheres.
7079 CONDUCTIVITY TRANSMITTER is designed to meet the need for a two-wire transmitter that produces a current output signal proportional to the selected range (conductivity or resistivity), with the option of intrinsically safe or explosionproof operation. Typical operations include hazardous environments in all processing industries.
7020 SERIES DISSOLVED OXYGEN ANALYZER AND PROBES The 7020 Series Dissolved Oxygen Analyzer system is unique in both operation and configuration. The system combines a patented equilibrium probe--unaffected by inert fouling or changes in flow conditions— with a full-function analyzer/controller in a weatherproof case. Typical applications include power generation, industrial and municipal wastewater, semiconductor, aquaculture, and food and beverage applications.
SODIUM ION MEASURING SYSTEM provides continuous, automatic measurement of sodium ion concentration in aqueous solutions. This highly sensitive system is composed of a microprocessor-based analyzer combined with a highly sensitive sodium electrode and a calibration facility. Typical applications include pure water applications, such as detecting deionizer breakthrough, boiler water carryover, and condenser leaks.
4112 DEW POINT AND TEMPERATURE TRANSMITTER represents a technological breakthrough in moisture measurement. The 4112 measures moisture and temperature in processes at temperatures up to 365°F (185°C), opening the door to better product quality, improved thermal efficiency, and longer process equipment life. Typical applications include industrial drying applications, including paper drying and foods and pharmaceuticals processing; trace moisture measurement in utilities, instrument-air, and heat-treat applications.
4114 DEW POINT AND TEMPERATURE TRANSMITTER offers high-performance water vapor measurement capabilities over very wide ranges of both moisture and temperature. It measures in-situ with an advanced solid-state, dual element sensor assembly that is able to withstand very harsh conditions. Typical applications include industrial drying applications where FM approval for explosion-proof areas or intrinsic safety is not a requirement.
4111 HUMIDITY TRANSMITTER The 4111 temperature-compensated Humidity Transmitter addresses the requirements for industrial humidity measurement. The transmitter is designed to provide premium performance using sensors proven to perform in hostile environments. Typical applications include hazardous, hostile industrial, chemical and pharmaceutical environments; environmental monitoring and food processing.
7866 THERMAL CONDUCTIVITY ANALYZER is designed to provide highly sensitive and accurate analysis of binary (two-component) gas mixtures. The analyzer can also be calibrated to measure a single component of a multicomponent gas mixture, providing the background gases constitute a stable mixture (such as air), or have approximately the same thermal conductivity. The most common application is at utilities or power plants in hydrogencooled generators. The triple-range analyzer measures the concentration of purge gas during start-up and shutdown of the generator, as well as the highpurity concentration of hydrogen during normal operations.
7082 SPECIFIC ION MONITOR/CONTROLLER is a microprocessor-based instrument for analysis of ion concentrations in industrial processes, and is functionally very similar to a pH Analyzer. It is used with Honeywell preamplifier electrode mounting and a variety of electrodes for the measurement of mono-valent and di-valent cations and anions. Ion concentration (or mV equivalent) and temperature are measured simultaneously with 1/2 second update of display, alarm/control outputs and analog outputs. Typical applications include sodium ion monitoring in high purity water treatment, low sodium food and beverage preparation, chemical processing and boiler water and steam monitoring.
70-82-02-01
REMOTE RANGE INDICATOR FOR 7866 TRIPLE RANGE ANALYZER enables operating personnel in a power plant to monitor hydrogen purity during “purge” and “operate” cycles from a second location, such as a control room or the plant floor. Although the 7866 Analyzer’s Control Unit has an integral indicating meter to display readings, it is usually located near the generator at the purge station. The Remote Range Indicator provides an additional display of the reading of the range being used. These ranges are 0-100% CO2 in Air, 0-100% CO2 in H2, and 100-75% H2 in Air, with the range indicated by one of three signal lights (green, amber and red). A calibrated 4-20 mA meter displays the output level of the 7866 Control Unit.
7872 SAMPLING SYSTEM includes all the equipment and accessories necessary to condition the sample by altering its pressure, temperature, and composition as required by the analyzer; to transport the sample from the process to the analyzer; and to dispose of the analyzed sample by venting to atmosphere. This sampling system is used in conjunction with the 7866 thermal conductivity analyzer for hydrogen cooled generators. 7931 EQUILIBRIUM DISSOLVED OXYGEN SENSOR measures independently of inert fouling or changes in flow rate. Since there is no net chemical reaction within the probe, there are no changes in probe composition, and the probe may be made permanent. All of these features lead to low maintenance and high reliability compared with older, diffusiondependent probes. Major applications are biochemical treatment of wastewater and corrosion control through boiler water treatment.
7773 MULTIPURPOSE pH & ORP ELECTRODE MOUNTINGS
HPW7000, Hi-pHurity WATER pH MEASUREMENT SYSTEM
Overall 7773 Mounting capabilities encompass the industrial measurements of pH, ORP (redox potential), specific ion and temperature in a flow or submersion configuration. Wetted material choices include 316 stainless steel, glass-fiber reinforced polypropylene or Ryton (Phillips Petroleum tradename for polyphenylene sulfide), for use in corrosive solutions at pressures up to 150 psig (1034 kPa) and temperatures up to 266°F (130°C). The 7773 is available in seven configurations; change between flow and immersion-type mounting requires substitution of only one part.
Accuracy and stability are combined with simplicity in this electrode mounting assembly for measuring pH in high purity water applications. The design includes a specially designed flow chamber that provides optimal flow patterns and volume. The electrode cover and holder is keyed so that proper alignment is maintained during installation. An easy to remove clamp secures the cover and makes electrode removal for calibration or maintenance fast and easy. Electrode and cable shielding ensures a stable pH reading. The reference electrode is easy to refill and maintain. A calibration cup holder allows the user to calibrate right at the assembly and saves calibration time.
7758 PIPELINE ELECTRODE MOUNTINGS FOR INDUSTRIAL pH AND ORP MEASUREMENTS The 7758 Pipeline Electrode Mounting uses a stainless steel or polypropylene bushing with 3/4” NPT for mounting in pipelines. It can also be mounted in larger pipe through the use of adapter bushings or by tapping directly into the pipe. It can be “side-mounted” in tanks. The mounting assembly is ideal for use in piped heavy slurries; it provides selfcleaning where oil and sludge tend to coat electrodes. It resists most chemical attack and may be used at high temperature and pressure. Typical applications include high purity water and sterilization processes.
7774 pH/ORP ELECTRODE INSERTION/REMOVAL ASSEMBLIES The 7774 Insertion/Removal Assemblies, which accommodate DURAFET and MEREDIAN series combination (single-probe) pH or ORP (redox) electrodes, are designed for use in processes under pressure, since the electrode can be inserted or removed without interrupting the process. Insertion can be into a pipeline, tank wall or other vessel—in any position— for applications such as boiler water analysis, demineralization, reverse osmosis, pharmaceutical and chemical production, waste treatment, and pulp and paper production.