Sealed Enclosure Cooling Thermoelectric Coolers

Thermoelectric Coolers Indoor/Outdoor

Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts INDUSTRY STANDARDS

ACCESSORIES

UR, cUR Recognized; Type 12, 3R, 4, 4X; File No. SA6453



 ptional thermolelectric temperature controller regulates O cooling and heating automatically Optional thermoelectric condenser manager helps direct condensation to the bottom of the enclosure

CE IP 65



APPLICATION

NOTES

Visit www.PentairProtect.com to download 2D and 3D CAD Thermoelectric Coolers minimize downtime and component loss drawings into the overall design of your electrical system. by removing heat around critical components within an enclosure. These compact, low-profile coolers using the Peltier effect allow for cooling of small indoor and outdoor enclosures. No condensers, compressors or filters are required making it a reliable solution for demanding low-maintenance environments.

FEATURES • • • • • • • • • •

 C Powered operation for 24V and 48V applications D Low profile design allows for mounting vertically and horizontally on any enclosure to avoid interference with internal components Filterless design reduces maintenance requirements Contains no refrigerant, making it earth friendly Prewired with simple terminal block for easy wiring connections Operates on the Peltier effect for cooling or heating Compressor-free air conditioning for demanding indoor and outdoor applications Shrouded and unshrouded models included in standard packages Operating temperature range -40 C (-40 F) to 55 C (131 F) Partial recess mount

SPECIFICATIONS •

Models 60 Watt, 24 Volt 100 Watt, 24/48 Volt 200 Watt, 24/48 Volt

FINISH •

1

 hrouded finish includes both powder coat paint RAL 7035 light S gray standard and stainless steel 304

Thermal Management

SUBJECT TO CHANGE WITHOUT NOTICE

EQUIPMENT PROTECTION

Spec-00580 I

Sealed Enclosure Cooling Thermoelectric Coolers

Performance Data  TE09 60W 204 BTU/Hr. (24 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) (W) Rated Current (Amps) at 131 F/131 F (55 C/55 C) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish

UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg)

EQUIPMENT PROTECTION

Spec-00580 I

24V w/o shroud TE090624020

24V w/ painted shroud TE090624010

24V w/ SS shroud TE090624011

178 52

178 52

178 52

55 / 131 -40 / -40

55 / 131 -40 / -40

55 / 131 -40 / -40

24 / 41 80 / 136 64

24 / 41 80 / 136 64

24 / 41 80 / 136 64

24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block

24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block

24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block

Type 12,3R,4,4X / IP 65

Type 12,3R,4 / IP 65

Type 12,3R,4,4X / IP 65

65 dBA

65 dBA

65 dBA

Anodized Aluminum N/A N/A

Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard

Anodized Aluminum Stainless Steel No. 4 Brushed Finish

9.06/230 4.84/123 6.91/176 6.00/2.70

9.29/236 5.02/128 6.94/176 7.80/3.60

9.29/236 5.02/128 6.94/176 7.80/3.60

PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com

Thermal Management

2

Sealed Enclosure Cooling Thermoelectric Coolers

:9    

 

 

 

 

 

0; ;

:9  

 

 

 

 

 

 

0; ;  

 

[

 

 

 



&XWRXW'LPHQVLRQV Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electrical system.

3

Thermal Management

SUBJECT TO CHANGE WITHOUT NOTICE

EQUIPMENT PROTECTION

Spec-00580 I

Sealed Enclosure Cooling Thermoelectric Coolers

Performance Data  TE12 100W 341 BTU/Hr. (24/48 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) (W) Rated Current (Amps) at 131 F/131 F (55 C/55 C) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish

UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg)

EQUIPMENT PROTECTION

Spec-00580 I

24V w/o shroud TE121024020

24V w/ painted shroud TE121024010

24V w/ SS shroud TE121024011

48V w/o shroud TE121048020

48V w/ painted shroud TE121048010

321 94

321 94

321 94

321 94

321 94

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

62 / 105 86 / 146 94

62 / 105 86 / 146 94

62 / 105 86 / 146 94

62 / 105 86 / 146 94

62 / 105 86 / 146 94

24 18 27.6 162

24 18 27.6 162

24 18 27.6 162

48 40 56.7 162

48 40 56.7 162

8.5

8.5

8.5

4.4

4.4

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

Type 12,3R,4,4X / IP 65

Type 12,3R,4 / IP 65

68 dBA

68 dBA

68 dBA

68 dBA

68 dBA

Anodized Aluminum N/A N/A

Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard

Anodized Aluminum Stainless Steel No. 4 Brushed Finish

Anodized Aluminum N/A N/A

Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard

11.81/300 6.02/153 7.40/188 8.50/3.90

12.00/305 6.18/157 7.43/189 11.00/5.00

12.00/305 6.18/157 7.43/189 11.00/5.00

11.81/300 6.02/153 7.40/188 8.50/3.90

12.00/305 6.18/157 7.43/189 11.00/5.00

Type 12,3R,4,4X / IP 65 Type 12,3R,4,4X / IP 65

PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com

Type 12,3R,4 / IP 65

Thermal Management

4

Sealed Enclosure Cooling Thermoelectric Coolers

:9 25 >@>@  

 

 

   

 

 

0; ;

:9 25 >@>@  

 

 

   

 

 

0; ;

 

[

 

 

 

 

 



&XWRXW'LPHQVLRQV Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electrical system.

5

Thermal Management

SUBJECT TO CHANGE WITHOUT NOTICE

EQUIPMENT PROTECTION

Spec-00580 I

Sealed Enclosure Cooling Thermoelectric Coolers

Performance Data  TE16 200W 682 BTU/Hr. (24/48 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) (W) Rated Current (Amps) at 131 F/131 F (55 C/55 C) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish

UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg)

EQUIPMENT PROTECTION

Spec-00580 I

24V w/o shroud TE162024020

24V w/ painted shroud TE162024010

24V w/ SS shroud TE162024011

48V w/o shroud TE162048020

48V w/ painted shroud TE162048010

567 166

567 166

567 166

567 166

567 166

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

55 / 131 -40 /-40

62 / 105 86 / 146 146

62 / 105 86 / 146 146

62 / 105 86 / 146 146

62 / 105 86 / 146 146

62 / 105 86 / 146 146

24 18 27.6 295

24 18 27.6 295

24 18 27.6 295

48 40 56.7 295

48 40 56.7 295

14.7

14.7

14.7

7.6

7.6

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

UR, cUR Recognized CE GOST Terminal Block

Type 12,3R,4,4X / IP 65

Type 12,3R,4 / IP 65

68 dBA

68 dBA

68 dBA

68 dBA

68 dBA

Anodized Aluminum N/A N/A

Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard

Anodized Aluminum Stainless Steel No. 4 Brushed Finish

Anodized Aluminum N/A N/A

Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard

15.75/400 7.09/180 7.25/184 14.80/6.70

15.93/405 7.35/187 7.27/185 18.60/8.40

15.93/405 7.35/187 7.27/185 18.60/8.40

15.75/400 7.09/180 7.25/184 14.80/6.70

15.93/405 7.35/187 7.27/185 18.60/8.40

Type 12,3R,4,4X / IP 65 Type 12,3R,4,4X / IP 65

PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com

Type 12,3R,4 / IP 65

Thermal Management

6

Sealed Enclosure Cooling Thermoelectric Coolers

:9 25 >@>@

 

 

 

   

 

 

7+58+2/( ;

:9 25 >@>@

 

 

 

   

 

[

 

 

0 ;

 

   

 

 



&XWRXW'LPHQVLRQV Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electrical system.

7

Thermal Management

SUBJECT TO CHANGE WITHOUT NOTICE

EQUIPMENT PROTECTION

Spec-00580 I

Sealed Enclosure Cooling Thermoelectric Coolers

Cooling Capacity versus Temperature D at 35 C (95 F) Ambientifference -27 F 1000 BTU/hr

-18 F

-9 F

0F

9F

18 F

27 F 293 W

TE0906XXXXX TE1210XXXXX

Cooling Capacity

800 BTU/hr

TE1620XXXXX

234 W

600 BTU/hr

176 W

400 BTU/hr

117 W

200 BTU/hr

59 W

0 BTU/hr -15 C

0W -10 C

-5 C

0C

5C

10 C

15 C

Temperature Difference (Inside - Outside)

EQUIPMENT PROTECTION

Spec-00580 I

PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com

Thermal Management

8

Sealed Enclosure Cooling Thermoelectric Coolers

Thermoelectric Temperature Controller

INDUSTRY STANDARDS UL Recognized; File No. 60730

FEATURES • • • • • • •

 rovides PWM regulation of cooling and heating output for TEC P units Automatically switches between cooling and heating 4 cooling temperature set points range from 22.5 C to 35 C (35 C Factory Setting) 3 heating temperature set points range from -5 C to 15 C (15 C Factory Setting) Heating function can be easily disabled if desired On-board LEDS indicate low temp, high temp alarm, and overall system status Dry contact relay output provides for external alarm indication

Performance Data  CATALOG NUMBERS ELECTRICAL DATA Rated Voltage (VDC) Operating Range (VDC) Current @ Rated Voltage (Amps) Operating Temperature Range Maximum (°F/°C) Minimum (°F/°C) Temperature Accuracy (°F/°C) Alarm Contact Rating

UNIT DIMENSIONS PCB Dimensions Height (in/mm) Width (in/mm) Length (in/mm) Weight (lb./kg) Mounting Bracket Dimensions Height (in/mm) Width (in/mm) Length (in/mm) Weight (lb./kg) Accessories Input Supply Harness Board to TEC Harness

9

Thermal Management

TEC24VCNTLRN

TEC48VCNTLRN

24 18 to 30 17.2

48 40 to 60 8.6

1) 0.5 A max @ 24 VDC - from same source of power as unit, SELV, non-power limited (greater than 15 W); OR 2) 0.5 A max @ 24 VAC - from, SELV, Class 2 safety isolating transformer.

131 / 55 -40 / -40 ± 3.6 / 2.0

1) 0.5 A max @ 48 VDC - from same source of power as unit, SELV, non-power limited (greater than 15 W); OR 2) 0.5 A max @ 24 VAC - from, SELV, Class 2 safety isolating transformer.

1.20 / 30 2.88 / 73 6.50 / 165 0.21 / 0.10 0.50 / 13 3.19 / 91 6.50 / 165 0.29 / 0.13 60-in. (1525mm) long Supply Harness Catalog Number TECSUPPLYHARNESS 36-in. (915mm) long Control Harness Catalog Number TECCONTROLHARNESS

SUBJECT TO CHANGE WITHOUT NOTICE

EQUIPMENT PROTECTION

Spec-00580 I

Sealed Enclosure Cooling Thermoelectric Coolers

Thermoelectric Condensate Manager

INDUSTRY STANDARDS

FINISH

Maintains UL/cUL Type 3R, 12, 4 and 4X rating when properly installed

FEATURES • • • •

• •

I ncludes all required hardware and vent drain Maintains the integrity of Type 4 or Type 4X enclosure Drains condensation to bottom of enclosure via vent drain (vent drain included with package) Utilizes existing mounting holes and fasteners of thermoelectric cooler that requires no additional mounting

 an Material Galvanized steel polyester powder coat paint with P RAL 7035 Vent drain material options include stainless steel or nonmetallic

Performance Data  CATALOG NUMBERS Fits TEC Unit Model UNIT CONSTRUCTION Pan Material Pan Finish Vent Drain Material UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm)

EQUIPMENT PROTECTION

Spec-00580 I

TEC60WCMSS4 All TE09

Stainless Steel .75/19 5.50/140 2.50/64

TEC60WCMNM All TE09

TEC100WCMSS4 All TE12

TEC100WCMNM All TE12

TEC200WCMSS4 All TE16

Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Non-Metallic Stainless Steel Non-Metallic Stainless Steel .75/19 5.50/140 2.50/64

.75/19 6.25/159 2.50/64

.75/19 6.25/159 2.50/64

PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com

.75/19 7.44/189 2.50/64

TEC200WCMNM All TE16

Non-Metallic .75/19 7.44/189 2.50/64

Thermal Management

10