Oscilla - excellence since 1960

a Oscill ce llen - exce 960 1 since Oscilla USB310 / 330 PC-based Screening Audiometer ® Features 11 frequencies: 125-8000 Hz (selectable in USB330...
Author: Gervase Barrett
82 downloads 2 Views 821KB Size
a Oscill ce llen - exce 960 1 since

Oscilla USB310 / 330 PC-based Screening Audiometer ®

Features 11 frequencies: 125-8000 Hz (selectable in USB330) -10 dB to 110 dB in 5 dB steps Left, right and binaural Pulse tone Warble tone (USB330) Noah compatible Includes: Device/headset with integrated patient response, AudioConsole, Carrying Bag.

4 automatic tests (1 in USB310 - 20 dB test) 24-bit digital audio quality Integrated patient response AudioConsole software Carrying bag

Oscilla USB350-B PC-based Diagnostic Audiometer ®

Features 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps 4 automatic tests Integrated patient response

Air and bone conduction Left, right and binaural Warble and pulse tone MCL, UCL and threshold Noah compatible

Narrow band masking SISI AudioConsole software Carrying bag

Includes: USB350-B device/headset with integrated patient response, Bone Conductor, AudioConsole, Carrying Bag.

Oscilla USB300-IB PC-based Diagnostic Audiometer ®

Earphones or Inserts

Features 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps 4 automatic tests

Bone conductor Narrow band masking SISI Noah compatible

AudioConsole software Flexible range of headsets Ideal for sound-proof booth Carrying bag

Includes: USB300-IB device, patient headphones or inserts, patient response, Bone Conductor, AudioConsole, Carrying Bag. Includes: USB300-I device, patient headphones or inserts, patient response, AudioConsole, Carrying Bag.

Oscilla USB350-SP PC-based Diagnostic Audiometer with Speech ®

Earphones or Inserts

Features 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps 4 automatic tests Air and bone conduction Warble and pulse tone

Pure Tone MCL, UCL and threshold Left, right and binaural Aided / unaided Masking: Narrow Band

Speech SRT, DS, MCL and UCL WAV-file and live-voice test Left, right and binaural Aided / unaided Masking: NB, WN and SN Noah compatible

Includes: USB350-SP device/headset with integrated patient response, Bone Conductor, Operator headset, AudioConsole, Carrying Bag.

Oscilla SM450-FF PC-based Diagnostic Audiometer with Speech and Free Field ®

Earphones or Inserts

Features 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps Pulse and warble tone Advanced audiometric tests (AC, BC, FF) Can be operated with / without operator headset Wall mountable

Pure Tone MCL, UCL and threshold Left, right and binaural Aided / unaided Masking: Narrow Band

Speech / Free Field SRT, DS, MCL and UCL WAV-file and live-voice test Left, right and binaural Aided / unaided Masking: NB, WN and SN Noah compatible

Includes: SM450-FF device, patient headphones, patient response, loudspeakers, bone conductor, USB 2.0 A/B cable, AudioConsole.

Oscilla AudioConsole ®

The AudioConsole software offers both advanced diagnostic and simple screening testing and journaling based on your preferences and devices. AudioConsole is multi-language and has a user friendly and intuitive interface making the operation easy and swift. AudioConsole alongside integrated remote support software allows for easy user support on site.

AudioConsole supports our “Dual Control” concept for all stand alone devices that have a USB port. Dual Control gives you full device control and live updating of measurements, both in audiometry and tympanometry. Audiology your way Dual Control gives you flexibility in operating the Oscilla® devices. You may operate the device alone, you may control the device from the PC, or switch between both. Dual Control supports audiometry as well as tympanometry.

AudioConsole has an improved tablet mode which allows you to use the software on any device running Windows® 8 Pro. AudioConsole interfaces with numerous patient journal systems and has its own built-in database from which measurement reports can be printed or exported in PDF format. AudioConsole contains an amazing report generator that allows you to change the predefine reports or totally customize your own reports with your logo and layout.

AudioConsole contains a wide range of automatic tests that can be customized to fulfil your needs. AudioConsole features a certified built-in Noah module that makes it possible to use all Oscilla® audiometers and tympanometers with Noah.

Oscilla SM910 / 910-B Screening Audiometer ®

Features Simple operation Portable and Inexpensive Pulse and Warble tone 11 frequencies: 125-8000 Hz -10 dB to 90 dB in 5 dB steps For quick manual screening - the battery version makes you 100% location-independent Includes: SM910 device, patient headphones, patient response, power supply AC 100-240V, 50-60Hz to 12V DC. Includes: SM910-B device, patient headphones, patient response, 4 x 1.5V batteries.

Oscilla SM920-P Screening Audiometer with built-in Printer ®

Features Perfect for screening Pulse and Warble tone 11 frequencies: 125-8000 Hz -10 dB to 110 dB in 5 dB steps

NOAH compatible Serial Port for PC-connection Built-in printer for quick test result printout Manual and automatic test (20 dB Random test)

Includes: SM920-P device with built-in printer, paper for internal printer, patient headphones, patient response, power supply AC 100-240V, 50-60Hz to 12V DC.

Oscilla SM930 Screening Memory Audiometer ®

Im meas port u to Au rements dioCo nsole

Earphones or Inserts

Features Flexible and versatile 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps

USB port for PC-connection Manual or automatic test (4 automatic tests) Programmable setup functions for additional features Option to visualize audiogram on PC during test Noah compatible

Includes: SM930 device, patient headphones, patient response, power supply AC 100-240V, 50-60Hz to 12V DC.

Oscilla SM950 Diagnostic Memory Audiometer ®

Earphones or Inserts

Im meas port u to Au rements dioCo nsole

Features Solid device with bone conduction 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps Manual or automatic test (4 automatic test) USB port for PC-connection Noah compatible

Option to visualize audiogram on PC during test Programmable setup functions for additional features Automatic print-out of complete audiogram on external printer

Includes: SM950 device, patient headphones, patient response, bone conductor, power supply AC 100-240V, 50-60Hz to 12V DC.

Oscilla SM950-S Diagnostic Memory Audiometer with Speech ®

Features 11 frequencies: 125-8000 Hz (selectable) -10 dB to 110 dB in 5 dB steps Bone conductor (-10 to 70 dB) Serial port for PC-connection Manual or automatic test (4 automatic tests) Option to visualize audiogram on PC during test Parallel port for printer connections (printer type can be customized) Automatic print-out of complete audiogram on external printer Programmable setup functions for additional features

Speech Warble tone Build-in microphone for talk-through Connection to MIC/TAPE/CD Narrow band masking (intensity up to 100 dB) Noah compatible

Includes: SM950-S device, patient headphones, patient response, bone conductor, power supply 12V AC.

Oscilla SM960-C Clinical Memory Audiometer ®

Features All-included classic clinical audiometer with 2 channels 11 frequencies: 125-8000 Hz (selectable) -10 dB to 120 dB in 5 dB steps or 1 dB steps Serial port for PC-connection Noah compatible

Pure and Wable tone Bone conductor (-10 to 70 dB) Parallel port for printer connections Built-in Talk-Through / Talk-Back monitor Connections for Bone, Insert and Free Field Automatic SISI, ABLB test, threshold and screening test Option to visualize audiogram on PC during test Masking: NB, WN, SN Programmable setup functions for additional features Calibrated speech audiometry by live voice or tape/CD Automatic print-out of complete audiogram on external printer

Includes: SM960-C device, patient headphones, 2 patient response, bone conductor, power supply 18V AC.

Oscilla TSM300 Screening Memory Tympanometer ®

Tympanometry Air pressure: -300 daPa to +200 daPa Ipsilateral reflex test: 5 frequencies (0,5kHz, 1kHz, 2kHz, 3kHz, 4kHz) Automatic probe seal detection Intensities: 105 dB SPL (all frequencies) Tympanogram and reflex tests are displayed live while being recorded Probe Tone Frequency: 226 Hz ± 1% Amplitude: 85 dB SPL ± 3 dB

Cost effective screening tympanometer for reliable test Easy daily use: Turn on device and insert probe Solid seal construction makes it suitable for screening of children Build-in memory for 20 measurements Serial port (PC connection or Thermo Printer) Parallel port (printer) Noah compatible

Includes: TSM300 device, probe, calibration cavities, power supply 220/12V DC, EarTip set.

Oscilla TSM400 Tympanometer ®

Im meas port u to Au rements dioCo nsole

Tympanometry Air pressure: -300 to +200 daPa Ipsilateral / Contralateral reflex test: 5 frequencies: 500Hz, 1KHz, 2KHz, 3KHz and 4KHz 85dB HL to 110dB HL in 5dB steps Probe tone: Frequency: 226 Hz ± 1% Amplitude: 85 dB SPL in 2ml, ± 3dB 7.2 inch High resolution colour display (800 x 480) Built-in memory for 200 measurements Noah compatible

Dual Control: True DUAL CONTROL: Totally flexible in operation. You may operate the device alone – you may control the device from the PC – or switch between. Live on-screen: Graphic tympanogram and reflex test Middle ear pressure (daPa) Ear canal volume (ml) Compliance (ml) and tympanogram width (daPa) Guiding assistant for probe and headset placement.

Includes: TSM400 device, probe, calibration cavities, paper for internal printer, power supply 220/12V DC, headset for contralateral tests, EarTip set.

Oscilla TSM500 combined Audiometer and Tympanometer ®

Im meas port u to Au rements dioCo nsole

Tympanometry Air pressure: -300 to +200 daPa Ipsilateral / Contralateral reflex test: 5 frequencies: 500 Hz, 1KHz, 2KHz, 3KHz and 4KHz 85dB HL to 110dB HL in 5dB steps Probe tone: Frequency: 226 Hz ± 1% Amplitude: 85 dB SPL in 2ml, ± 3dB 7.2 inch High resolution colour display (800 x 480) Built-in memory for 200 measurements Noah compatible

Dual Control: True DUAL CONTROL: Totally flexible in operation. You may operate the device alone – you may control the device from the PC – or switch between. Live on-screen: Graphic tympanogram and reflex test Middle ear pressure (daPa) Ear canal volume (ml) Compliance (ml) and tympanogram width (daPa) Guiding assistant for probe and headset placement.

Includes: TSM500 device, probe, calibration cavities, patient headphones, patient response, bone conductor, power supply 220/12V DC, EarTip set.

Oscilla Audiometer Stand-alone audiometer SM910 Screening

SM910-B (Battery) SM920-P SM930 SM950

Dianostic

SM950-S TSM500 (Audiometer part)

Clinical

SM960-C

Output Transducers Air Insert Bone conphones conduction duction

• • • • • • • •

4 Automatic test Max. dB level

20 dB test

20 dB Random test

xx dB Random test

Pure Tone Audiometry HugsonWestlake

90 90 110

o o o o o

110

• • • •

110 110 110 120

• • • • •

• • • • •

• • • • • •

• • • • •

Pulse

Warble

• • • • • • • •

• • • • • • • •

Disable frequencies

• • • • • •

Masking

NB, WN, SN

Adjustable tone lenght

Heard/ not heard

• •

• • • • •

NB, WN, SN

• •

NB

USB-Based Audiometer USB310 Screening

USB330 USB300-I USB300-IB

Dianostic

USB350-B USB350-SP SM450-FF

• • • • • • •

110 110

• • o o o

110

• • • •

110 110 110 110

• • • • • • •

• • • • • •

• • • • • •

• • • • • •

• •

• • •

• • • • • •

• • • • • •

NB NB NB, WN, SN NB, WN, SN

• • • • • • •

Oscilla tympanometer features

Screening

TSM300

Dianostic

TSM400 TSM500 (Tympanometer part)

Middle ear pressure

Ear canal volume

Compliance

Ipsi reflex

• • •

• • •

• • •

105 dB SPL

Contra reflex

85-110 dB HL

85-110 dB HL

85-110 dB HL

85-110 dB HL

Selectable reflex level

• •

Auto-start function

Probe tone

• • •

226 Hz 226 Hz 226 Hz

Speech Audiometry ABLB

MCL/ UCL

Speech audiometry

Miscellaneous Features Live Voice

Binaural testing

Integrated patient response

LCD screen

Memory capacity

PC Dual connection Control

Noah compatible (via AudioConsole)

• • • • • •

Serial

external source

• colour



external source

• • •

built-in built-in



• •

• • • • • • •

100 measurements

USB

100 measurements

USB

29 measurements

Serial

200 measurements

USB

17 measurements

Serial

• • • • • •

Import measurements to AudioConsole

• • •

AudioConsole

• • •

USB USB USB USB USB USB

Weight

o

650 g

o

o

650 g

o

o

935 g

o

1000 g

o

o

1000 g

o

o

1000 g

o

1000 g

o

o

1000 g

• • • • • • •

• • • • • • •

500 g

o

• • • • • • •

USB

Carrying bag

o

Built-in printer





500 g 500 g 500 g 500 g 500 g 500 g

Hardware miscellaneous features Built-in printer

• •

LCD screen

PC connection

Memory capacity

b/w

serial

20 measurements

colour

USB

200 measurements

colour

USB

200 measurements

Import measurements to AudioConsole

Dual Control

• •

AudioConsole

Carrying bag

Noah Compatible (via AudioConsole)

o

o

o

o

o

o

• • •



included

o optional extra

Time and date storage

Weight 1000 g

• •

1000 g 1000 g

Specifications subject to change without notice.

What our customers say “Oscilla® always works” “Oscilla® is so easy to operate” “Oscilla® is incredibly simple to calibrate”

Johann Gutenbergs Vej 3 8200 Aarhus N – Denmark Tel. 0045 8674 2622 www.oscillahearing.com – [email protected]