optiPoint 410
Siemens
optiPoint 410
Contents 1 1.1 1.2 1.3 1.4 1.5 1.6
1.7
optiPoint 410 Family. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Overview of the terminals and the optional modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Feature Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Terminal settings for optiPoint 410 entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.6.1 Entering the administration area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.6.2 Only if no DCHP-Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.6.3 Working in a virtual LAN (VLAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.6.4 Other settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.6.5 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.6.6 View settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.6.7 Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.6.8 Reset factory setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.6.9 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.6.10 Status Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 1.6.11 Binary encoded ASCII table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1.6.12 Operation codes summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Relevant AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
EN4416EN20EN © 2004 Siemens AG
1
Siemens
2
optiPoint 410
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
1 1.1
Siemens
optiPoint 410 Family General informations
The terminals of the optiPoint 410 family can be connected as IP-phones to the HiPath 3000 and HiPath 4000 systems.
1.2
Overview of the terminals and the optional modules
●
EN4416EN20EN © 2004 Siemens AG
optiPoint 410 entry –
IP standards: - HFA - H323, CorNet IP, SIP - G.711, G.723, G.729 A / AB, QoS, Security H.235 - SNMP, HTTP, DHCP, FTP
–
10/100Base-T, VLAN support
–
Power over LAN resp. power supply unit
–
CTI (TAPI) applications
–
No display
–
Eight function keys with LED
–
Two keys (+/-) for settings ringer tone volume, ringer pitch and alerting tone
–
No adapter ports for add-on modules
–
No key module- and display module - interface
–
Wall mountable
–
Colors: arctic, mangan
3
optiPoint 410
Siemens
●
optiPoint 410 economy –
IP standards: - HFA - H323, CorNet IP, SIP - G.711, G.723, G.729 A / AB, QoS, Security H.235 - SNMP, HTTP, DHCP, FTP
–
10/100Base-T, VLAN support
–
Power over LAN resp. power supply unit
–
CTI (TAPI) applications
–
4
Alphanumeric LCD swivel display 2 lines (24 characters per line)
–
12 function keys LED
–
Two keys (+/-) for settings ringer volume, ringer pitch and alerting tone
–
Three dialog keys for easy menu navigation and selection
–
Loudspeaker
–
No adapter ports for add-on modules
–
No key module- and display module - interface
–
Wall mountable
–
Colors: arctic, mangan
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
Siemens
●
optiPoint 410 standard –
IP standards: - HFA - H323, CorNet IP, SIP - G.711, G.723, G.729 A / AB, G.722, QoS, Security H.235 - SNMP, HTTP, DHCP, FTP
–
10/100Base-T, mini-switch (VLAN) support
–
Power over LAN resp. power supply unit
–
CTI (TAPI) applications
–
– –
EN4416EN20EN © 2004 Siemens AG
Alphanumeric LCD swivel display 2 lines (24 characters per line) additional background lighting 12 function keys with LED Support of self labeling keys (TBD)?
–
Two keys (+/-) for settings ringer volume, ringer pitch and alerting tone
–
Three dialog keys for easy menu navigation and selection
–
Full duplex handsfree talking
–
Two adapter ports for add-on modules
–
Self labeling key module - and display module - interface
–
Wall mountable
–
Colors: arctic, mangan
5
optiPoint 410
Siemens
●
optiPoint 410 advance / advanced SLK –
IP standards: - HFA - H323, CorNet IP, SIP - G.711, G.723, G.729 A / AB, G.722, QoS, Security H.235 - SNMP, HTTP, DHCP, FTP
–
10/100Base-T, mini-switch (VLAN) support
–
Power over LAN resp. power supply unit
–
CTI (TAPI/JTAPI) applications
–
USB master port
–
One headset port (121 TR9-5)
–
Excellent audio quality with “Speech Extender”
–
LCD swivel display with 4 lines (24 characters per line) additional background lighting
–
19 function keys with LED
–
6
18 function keys with LED SLK
–
Support of the self labeling keys (TBD) (advance-SLK);
–
Two keys (+/-) for settings ringer volume, ringer pitch and alerting tone
–
Three dialog keys for easy menu navigation and selection
–
Loudspeaker
–
Full duplex handsfree talking
–
1 port for add-on modules
–
Self labeling key module - and display module - interface
–
Wall mountable
–
Colors: arctic, mangan
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
Siemens
●
AP1120 –
Connection to STMI 2 for HFA
–
2x RJ11 for analog devices
–
1x 10/100 BaseT Ethernet access
–
10/100 BaseT Ethernet, inline powered
–
EN4416EN20EN © 2004 Siemens AG
Connection for analog Fax devices
7
optiPoint 410
Siemens
●
●
8
optiPoint 410 key module and self labeling key module –
16 function keys with LED
–
Maximum one key module per terminal
–
Button is twice verifiable for named buttons
–
Colors: arctic, mangan
optiPoint 410 Self Labling Key Module –
13 function keys with LED
–
Indication of the key function, name or phone number over integrated LCD displays.
–
Button is fourfold verifiable with key functions or named buttons and get select over the Shift button (button 13).
–
Maximum one key module per terminal
–
Colors: arctic, mangan
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
Siemens
●
EN4416EN20EN © 2004 Siemens AG
optiPoint 410 Display Module –
Big LCD display with tochscreen function (320x240) and additional background lighting
–
Swivel display
–
Applications: -Graphical user interface for telephony -Online help -JAVA platform, JDK (only for advance) -Local, personal telephon book -Access to “Corporate directories” via LDAP -WML/HTML Browser -Voice dialing -Callog list
–
Colors: arctic, mangan
9
optiPoint 410
Siemens
●
optiPoint analog adapter –
Permits to connect an analog terminal (connection with an own RG (ring generator), a/b-Adapter)
–
External power supply necessary
–
●
No service fax
optiPoint acoustic adapter Permits to connect telephony accessories : –
aktive speaker, external microphone via Y-Kabel
–
Headset (wired or wireless official 121 TR9-5)
–
●
10
dry contact "contact adapter" e.g. door opener, Busy display, second bell.
optiPoint recorder adapter –
external recorder connection or secondary speaker
–
Second handset
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
1.3
Siemens
●
optiPoint signature module
●
Telephone adapter for Chipcard reader (Smart Card Applikation)
●
The cards are programmed with the help of a card reader and a PC program
●
max. 1 module per telephone can be connected
●
Colors: arctic, mangan
Feature Description
●
The new optiPoint 410 terminal is available in four different configurations.
●
1 Terminal has no display, 3 include a display.
●
Only 2 key modules can be connected.
●
All optiPoint 410 have the same UI (user interface) as the optiPoint 500 terminals.
●
Display of country-specific characters is supported.
●
The integrated USB 1.1 interface is used to connect an external keyboard.
●
When adapters or add-on-modules are used, the wall mounting option is not possible.
1.4
Service Information
●
Care has to be taken, that the correct Key standard for optiPoint 410 is always used (T8 for optiPoint 410 entry, T12 for optiPoint 410 Eco and standard, T18 for optiPoint 410 advance SLK and T19 for optiPoint 410 advance). In addition, button standards are provided for use of SLK-Keymodulen (13 buttons).
●
To reach the "Configuration Menu" of the terminal, the buttons 1 0 3 have to be pressed at the same time.
EN4416EN20EN © 2004 Siemens AG
11
optiPoint 410
Siemens
1.5
HiPath 4000 V2.0
●
The optiPoint 410 are generated in the same way as the optiPoint 400. New parameters in AMO SBCSU:...CONN=IP2, if the terminal is connected to a STMI2 board.
●
In the AMO ZAND the type=optiset is also valid to the optiPoint 410.
●
The OPTIABA (optipoint analog adapter) is added automaticly when an analog terminal is plugged in (general: ANADEV generated). An advisory message confirms this. An OPTIUSB may additionaly be configured at the same optiPoint 410/600. It is not permitted to establish another TA a-b.
FAX and Modem funtionality with “optiPoint analog adapter” in optiPoint IP Telefone is not supported.
12
EN4416EN20EN © 2004 Siemens AG
optiPoint 410
Siemens
A suitable power supply has to be used for a configuration with an optiPoint analog adapter.
●
Max. one "optiPoint signature module" is possible per terminal
●
An "optiPoint key modules SLK" may only be connected/disconnected to an optiPoint410 in the power off condition
●
An optiClient 130 is configured like a corresponding optiPoint telephone. An exchange of an optiPoint IP telephone for an optiClient 130 soft client is possible
●
The “OptiPoint display module” for the Optipoint 410 family can not be added to an optiPoint500 or 600
●
There can be only one OptiPoint display module connected to an optiPoint 410
●
An "optiPoint display module" must always be attached directly to the optiPoint 410
EN4416EN20EN © 2004 Siemens AG
13
Siemens
14
optiPoint 410
EN4416EN20EN © 2004 Siemens AG
Terminal settings for optiPoint 410 entry
1.6
Terminal settings for optiPoint 410 entry
1.6.1
Entering the administration area edg
Siemens
Press the keys simultaneously The status of all 8 LEDs should be ON
o
Enter admin password (default: 123456 -> see 91 in original)
r
Terminate the operation. You are now in the Administration Area (All 8 LEDs flash).
The top two function keys take over the following functions in this area: 1st Function key Press key to make settings.
2nd Function key Press key to view settings.
1.6.2
Only if no DCHP-Server Change to the Administration Area. Press key (Key 1).
ddd r
de
© 2004 Siemens AG
Terminate the operation. Press key (Key 1).
EN0000DE00EN
Enter code to switch the DHCP IP assign off.
Enter code.
o
Enter IP-Adresse of the optiPoint 410 entry (to edit see -> page 93 in original)
r
Terminate the operation.
15
Terminal Settings for optiPoint 410 entry
Siemens
Press key (Key 1).
df o
Enter Netzwork mask of the optiPoint 410 entry (to edit see -> page 93 in original)
r
Terminate the operation. Press key (Key 1).
dg
1.6.3
Enter code.
o
Enter Default Route of the optiPoint 410 entry (to edit see -> page 93 in original)
r
Terminate the operation.
Working in a virtual LAN (VLAN) Press key (Key 1).
fid r
Enter code to define the manual configuration of the VLAN Discovery Mode. Terminate the operation. Press key (Key 1).
fh
16
Enter code.
Enter code.
o
Enter (0 - 4095) for the Virtual LAN ID -> page 80 in original ((to edit see -> page 93 in original)
r
Terminate the operation.
EN0000DE00EN © 2004 Siemens AG
Terminal Settings for optiPoint 410 entry
1.6.4
Siemens
Other settings All other settings of your optiPoint 410 entry must be made through the "Web-based Management Tool" Öffnen Sie Seite „System“ in Ihren Browser und tragen Sie folgende Parameter ein: ●
PBX address
●
Station number
●
Station password
●
System type
Confirm your entries and start the telephone: Press key (Key 1).
mm r
Enter code. Terminate the operation.
After the start, the telephone is silent and you can make the other settings
1.6.5
Administration There are different ways to make settings for the optiPoint 410 entry. ●
Locally on the terminal: –
●
EN0000DE00EN © 2004 Siemens AG
optiPont 410 entry ---> page 48 in original
Remote maintenance via LAN: –
Web-based Management Tool -> page 53 in original
–
Deployment Tool ((for further information see "Administration Manual Deployment Tool").
17
Terminal Settings for optiPoint 410 entry
Siemens
1.6.6
View settings You can make the system display the important settings of your optiPoint 410 entry. Change to the Administration Area.
Press the 2nd function key from the top.
o
Enter 2-digit code (Table -> page 102 in orginal) for the desired function.
r
Terminate the operation.
The settings are displayed through different illuminations of the LEDs. The table on -> page 99 describes the meaning of the LEDs.
1.6.7
Restart Change to the Administration Area ehk
Press keys simultaneously.
or gir o
Press keys simultaneously. Enter the Administrator password (default: 123456 -> page 91 in original).
During start-up the LEDs momentarily illuminate in succession.
18
EN0000DE00EN © 2004 Siemens AG
Terminal Settings for optiPoint 410 entry
1.6.8
Siemens
Reset factory setting The resetting can lead to the failure of all the functions of the Atlantic. Ensure that you have all the necessary information for start up -> Seite 14 im Original.
For default values, see -> page 95 in original.
Disconnect the Western plug of the power supply unit cable or, if “Power over LAN”, disconnect the LAN cable from the optiPoint 410 for a few seconds. n flm
EN0000DE00EN © 2004 Siemens AG
Lift handset Press keys simultaneously.
o
Enter the reset passwort (124816).
r
Terminate the operation.
t
Replace the handset.
19
Terminal Settings for optiPoint 410 entry
Siemens
1.6.9
Error messages The LEDs flash till you switch to the Administration Mode
-> page 17 (in original). LEDs am Telefon:
No IP address
The DHCP server cannot assign a terminal IP address -> page 79 (in original). Possible solution Check the DHCP server.
No Terminal Mask
The DHCP server cannot assign a terminal screen -> page 79 (in original). Possible solution Check the DHCP server.
No Default Route
The DHCP server cannot assign a default route -> page 67 (i.O.) Possible solution Check the DHCP server.
20
EN0000DE00EN © 2004 Siemens AG
Terminal Settings for optiPoint 410 entry
Siemens
No IP address is set DHCP IP Assignment (i.O.) is switched off and there is no terminal IP address configured. Possible solution
Activate the DHCP IP assignment -> page 15 (i.O.) .
Enter the terminal IP address -> page 15 (i.O.) . No Terminal Mask is set DHCP IP Assignment -> page 68 (i.O.) is switched off and no terminal mask is configured. Possible solution
Activate the DHCP IP assignment -> page 15 (i.O.) . Enter the terminal IP address -> page 15 (i.O.) . No Default Route is set DHCP IP Assignment -> page 68 (i.O.) is switched off and no default route is configured. Possible solution
Activate the DHCP IP assignment -> page 15 (i.O.) . Enter the default route -> page 15 (i.O.) . No station number / password The Number -> page 79 and/or password ->‡ page 79 (i.O.) are not configured. Possible solution Enter station number -> page 16 (i.O.) . Enter station password -> page 16 (i.O.) .
EN0000DE00EN © 2004 Siemens AG
21
Terminal Settings for optiPoint 410 entry
Siemens
No netzwork
The telephone cannot find the network. Possible solution Check the network cable.
No PBX address No PBX address -> page 77 (i.O.) Possible solution Enter PBX address -> page 16 (i.O.).
PBX does not react The terminal cannot find the PBX -> page 84 (i.O.). Possible solution Check PBX.
Login failed The PBX No. -> page 77 (i.O.), station No.-> page 79 (i.O.), and/or station password -> page 79 (i.O.) are invalid. Possible solution Change the PBX address -> page 77 (i.O.). Change the station No. -> page 79 (i.O.). Change the station password -> page 79 (i.O.).
22
EN0000DE00EN © 2004 Siemens AG
Terminal Settings for optiPoint 410 entry
1.6.10
Siemens
Status Messages
Quiescent state
Administration state
System error
LED = OFF LED = ON
EN0000DE00EN © 2004 Siemens AG
23
Terminal Settings for optiPoint 410 entry
Siemens
1.6.11
Binary encoded ASCII table
The table illustrates in which way characters are displayed on the LEDs of the optipoin 410 entry.
.
0
1
2
3
4
5
6
7
8
9
LED is ON LED is OFF
24
EN0000DE00EN © 2004 Siemens AG
Terminal Settings for optiPoint 410 entry
1.6.12 ●
Operation codes summary
Administration area Function
Administration area ●
Siemens
optiPoint 410 entry edg (simultaneous) o r
Configurations Function
Default Route
optiPoint 410 entry
dg o r
Refer to Æ Page 18 Refer to --> Page 67
DHCP IP Assignment
v
dd o r
--> Page 68
Factory Reset
flm (simultaneous) o r
--> Page 70
Terminal IP Address
de o r
--> Page 79
Terminal Mask
df o r
--> Page 79
VLAN id
fh o r
--> Page 80
VLAN Method
fi o r
--> Page 80
●
Additional functions Function
optiPoint 410 entry
Restart phone
ehk (simultaneous) oder g ir (simultaneous) o(Administrator password) r
Start phone
EN0000DE00EN © 2004 Siemens AG
Refer to
mm r
25
Siemens
26
Terminal Settings for optiPoint 410 entry
EN0000DE00EN © 2004 Siemens AG
Siemens
1.7
Relevant AMOs
AMO
Parameter
Sprache/ Language
Beschreibung/Description
SBCSU
GERKON
d
OPTIIP Sprachterminal IP (optiPoint 400/410//600 und optiClient 130)
DVCFIG
e
OPTIIP digital voice terminal IP (optiPoint400/410/600 and optiClient 130 )
ANSCHL
d
IP, wenn an STMI, IP2, wenn an STMI2 angeschlossen
CONN
e
IP, if connected to STMI; IP2, if connected to STMI2;
TAWL
d
Ausweisleser vorhanden
IDCR
e
station with identity card reader
DIGTYP
d
OPTIT8 (optiPoint 410 entry), OPTIT12 (optiPoint 410 eco / standard), OPTIT18 (optiPoint 410 advance SLK), OPTIT19 (optiPoint 410 advance)
DIGTYP
e
OPTIT8 (optiPoint 410 entry), OPTIT12 (optiPoint 410 eco / standard), OPTIT18 (optiPoint 410 advance SLK), OPTIT19 (optiPoint 410 advance)
V2RUFKLG
d
Initalisierungswert für optiPoint Rufklangfarbe
V2RINGSO
e
Initial value for optiPoint 500 ringer sound
AUSGBKON
d
Initalisierungswert für optiPoint Ausgabe Kontrast.
DISPCONT
e
Initial value for optiPoint Display Contrast.
ROLLLAUT
d
Initalisierungswert für Rollover-Laut.
ROLLVOL
e
Initial value for rollover ring volume
RFOUEB
d
Rückfrage ohne Uebergeben durch Einhängen
CONSONLY
e
Consult Only
HAMESCR
d
Ein/ausschalten 'Hauptmenu ueber Scrolltasten'
MAMESCRL
e
Act/deact system option 'Mainmenu by scrollkey
SRVANRUF
d
Ein/ausschalten 'Kein Servicemenue bei aktivem Lautsprecher'
MAMESCRL
e
Act/deact system option 'Mainmenu by scrollkey'
PICKOPT
d
Ein/ausschalten 'Pick oder Pick-Pick '
PICKOPT
e
Act/deact system option 'pick or pick-pick mode'
TAPRO
ZAND: Optiset
EN4416EN20EN © 2004 Siemens AG
27
Siemens
AMO
28
Parameter
Sprache/ Language
Beschreibung/Description
ATONNULL
d
Aufmerksamkeitston kann null sein
ATONZERO
e
Alerttone volume can be set to zero
EN4416EN20EN © 2004 Siemens AG