OPERATING MANUAL-10DPS75 VERSION 1.0

OPERATING MANUAL-10DPS75 VERSION 1.0 www.blastrac.com Operating manual 1-10DPS75 02/12 EC DECLARATION OF CONFORMITY in accordance with Appendix I...
Author: Angelina Wilcox
12 downloads 0 Views 6MB Size
OPERATING MANUAL-10DPS75 VERSION 1.0

www.blastrac.com

Operating manual 1-10DPS75

02/12

EC DECLARATION OF CONFORMITY in accordance with Appendix II sub A of Directive 2006/42/EC BLASTRAC B.V. Utrechthaven 12 NL - 3433 PN NIEUWEGEIN Tel: 0031 (0)30 601 88 66 Fax: 0031 (0)30 601 83 33 [email protected] The Netherlands

Declare under our sole responsibility that the machine as described below Conforms with the Health and Safety requirements of the European Directive of the machine Safety. In case of changes to the machine without our written authorization this declaration loses its validity.

Model:

BLASTRAC 1-10DPS75/……….

Serial number: ……….

1. satisfies the conditions set out in the Machine Directive (Directive 2006/42/EC); Low voltage directive (2006/95/EC, as last amended; EMC directive 2004/108/EC, as last amended) 2. satisfies the following harmonized standards: NEN-EN 349, NEN-EN 418, NEN-EN 294 and NEN-EN 60204

Nieuwegein …………

2

Operating manual 1-10DPS75

03/12

Index EC Declaration of Conformity

02

1. Index

03

2. Machine description

04

3. Safety Safety equipment Safety regulations Safety instructions

05

4. Initial operation Checkpoints powersupply Checkpoints of machine

07

5. Operation Before switch on Switch on the machine Switch off the machine

08

6. Maintenance Changing the liners Changing the tune-up kit

09

7. Selection of abrasive

10

8. Technical data

11

Contact

12

3

Operating manual 1-10DPS75

04/12

1. Index It is important that all persons operating and maintaining the machine read this manual carefully and understand it fully. Keep this manual near to the machine, so that it can be consulted every time. Only authorized and trained personal may operate the machine.

2. Machine description The Blastrac blast cleaning machine 1-10DPS75 is a downward blasting machine with a closed abrasive circuit designed for the pre-treatment of horizontal surfaces. The bouncing impact of metallic abrasive onto the surface to be treated thoroughly removes surface contaminants, coats of paint, sealants and thin coatings. A suitable filter unit must be connected to the machine in order to separate the dust from the abrasive. A specially designed dust collection system ensures dust-free operation of the machine and clean air at the workspace.

1

Clamp for dust hose and electrical cable

6

Emergency shutdown switch

11 Speed control

2

Connection pipe for dusthose

7

Push button blastwheel on/off

12 Travel switch

3

Abrasive control cable

8

Main switch

13 Quick release pin

4

Ammeter blastmotor

9

Overdrive

14 Feed spout

5

Hour counter

10 Move forwards

4

Operating manual 1-10DPS75

05/12

3. Safety Before operating the machine, the personnel must be familiar with the safety instructions given in this manual. Only authorized and trained personal may operate the machine. Keep this manual near to the machine, so that it can be consulted every time. Safety equipment  The surface to be treated must be swept, remove stones, screws etc..  Never use the machine when the surface is not clear and if there is a risk of stumble. The workplace must be good lighted.  Remove electrical cables and dust hose from surface to be treated  Work concentrated during operating the machine  Always use a dustcleaner Safety regulations  Persons who do not operate the machine are not permitted to stay in the surrounding of the machine. Don’t leave children anyway.  Keep the machine original; Use cables who are approved and not damaged. Never remove the earth connecting of the supply cable and machine. Use only cables with earth wire and connectors with a earth connecting.  Connect main power supply cable to a installation with a earth leakage circuit breaker.  Inspect and test the electrical components of the machine regularly. This electrical components have to satisfy to the requirements EN60204-1.  Always call a skilled electrician when you have questions about the safety of the electrical components.  Work on electrical equipment or operating materials may only be undertaken by a skilled electrician or by trained persons under the guidance and supervision of a skilled electrician as well as in accordance with the electrical engineering regulations.  Pull out the main plug during inspections and repairing on the machine.  Never operate the machine when workplace is wet.  Never stay in the rain with the machine.

5

Operating manual 1-10DPS75

06/12

Figure below is placed on the machine.

Meaning of the symbols:  Ear protection is obliged  Safety glasses with lateral protection is obliged  CE-mark on this machine  Safety shoes obliged  Consult the manual before operating the machine. Personnel must tie back long hair and not wear loose clothing or jewellery including rings. Wear gloves and dust mask during operating the machine. Safety instructions  Abrasive can escape from the sides of the blast head at high speed. Wear safety glasses with lateral protection and close-fitting protective clothing.  Be very careful with inserting the quick release pin  The machine, specially the handle grip must be free of fats and has to be dry.  The dust container of the filter unit must be emptied regularly. Comply with the local waste treatment regulations considering the removed material.  The weight of the 1-10DPS75 is 211 kg. By transport the machine with a crane or lift, use the lifting eyes of the machine  Pay attention that the drive unit do not turn away during lifting the machine.

6

Operating manual 1-10DPS75

07/12

4. Initial operation It is committed to inspect the machine before use it. It is not permitted to use the machine if the machine safety is not according the checkpoints below. Checkpoints powersupply  Use only extension cables for extending the main cable that are sized and marked in accordance with the overall power consumption of the machine.  Electrical cables must be fully unwind of them reels.  No damage is permitted for electrical cables.  Use a electrical power supply connection with earth connecting.  The circuit breaker of the power supply must have a ‘’D’’ characteristic. Circuit breakers with a “C” or “B” characteristic can give problems by switch on the blastmotor. Checkpoints of machine  Safety functions and operating functions must work correct.  Check the following parts for damage and wear: blastwheel, feedspout, liners, magnet- and brush sealing.  No loose bolts and nuts permitted  No any damage of electrical components permitted.  Dust hose must be undamaged and the connection must be reliable.  Check the parts of the separator on wear and defects. Remove foreign bodies and dust deposits.

7

Operating manual 1-10DPS75

08/12

5. Operating To operate the 1-10DPS75 the following instructions are committed Before switch on     

Check if the distance from magnet to the floor is 6 – 8 mm. Check this height with aluminium strips. Check the distance from brush sealing to the floor. This may be max. 1 mm. Fill the separator equally with the selected abrasive up to the bottom of the separator tray. Magnetic valve must be closed whilst doing this. Connect the blastmachine and filterunit with the dusthose. This connection must be reliable. Connect the power supply cable of the filterunit with the generator. Be sure that electrical power supply is correct.

Switch on the machine

   



Before switch on the blastmachine, switch on the filterunit. Press the green push button “Blastwheel ON”and check the rotating direction of the blastmotor. The correct direction is given with a arrow on the housing of the motor. Select the speed using the speed control knob. (item 11 of machine description) When the machine is traveling pull the abrasive control cable to open the magnetic valve. Observe the ammeter. It may indicate the full load amperage. After having blasted aprox. 2 m, close the abrasive valve, stop the machine and check the blasted surface. If the ‘hotspot’ is too much on the right, turn clockwise the cage a little bit. Never adjust the cage during blasting.

Switch off the machine

     

Close the abrasive valve Press the red button “Blastwheel OFF” Switch the main switch to position “OFF” Pull out the connector of the main power supply of the machine. Switch off the filter unit. Wait for standstill of all drives before any inspection or maintenance works are started.

8

Operating manual 1-10DPS75

09/12

6. Maintenance Changing the liners

 

Loose the press bolt of the top liner and remove the cover. Loosen the nuts of the side liners and plenum liners. Take them out at the bottom of the housing.

To mount the liners, keep on the following sequence:  First place the plenum liners and fix them with the nuts.  Place the side liners inside the housing. The sideliners may stick out the body for max. 1mm. Tighten the nuts.  Place the top liner in the housing and make sure that the top liner sits close to the edges of the side liners.  Place the cover and tighten the bolts.  Tighten the pressure bolt of the top liner slightly and press the top liner against the side liners. Changing the tune-up kit De tune-up kit consists of the blastwheel, the cage and a bolt.

    

Remove the feed spout Remove the cage clamps Remove the cage and blastwheel cover plate Block the blastwheel and remove the central fixing bolt Take the blastwheel out of the housing

Use a new central fixing bolt when mounting a new blastwheel

    

Place the blastwheel on the hub and tighten the central fixing bolt. Fix the blastwheel cover plate with 4 nuts Insert the control cage in the center and clamp the cage with the control clamps so that the blastwheel can rotate freely Turn the blastwheel manually. It must rotate freely. Place the feed spout between the abrasive valve and the cage.

Clean the machine every day with air and non-aggressive materials. Never use a high pressure water cleaner to clean the machine. Store the cleaned machine in a dry room. Protect the electrical motor from moisture, heat dust and shocks. Remove the abrasive out of the abrasive storage hopper. All repair work has to be done by qualified Blastrac personnel, this guarantee a safe and reliable machine. Any guarantee on the machine is expired when:

  

By not using original Blastrac spare parts and abrasive. When repair work is not done by qualified Blastrac personnel. When changes, add-ons or conversions are undertaken without written permission of Blastrac BV.

9

Operating manual 1-10DPS75

10/12

7. Selection of abrasive Media nr. 2 Is often used when the surface is only subsequently sealed. − creates fine profiles, e.g. on vacuum concrete and non-glazed tiles − removes thin layers of rust on steel surfaces − removes thin layers of paint Media nr. 3 − creates a fine to medium texture on concrete. − removes glazing from tiles prior to subsequently coating with antiskid floor sealings − removes old impregnations and coatings about 1 mm thick Media nr. 4 Standard abrasive, suitable for about 50-60 % of all applications. Creates a medium profile on concrete. Fulfils the same purpose as Media No. 3 when a higher speed of the machine is required, e.g. on asphalt, in order to keep the thermal load low. − removes laitance from new concrete − roughening of smooth concrete or natural stone − removes coatings with a thickness of 1-3 mm − cleaning of steel surfaces Media nr. 5 This media is used to create a coarse profile or to increase the work speed in the case of surfaces hard to treat. − removes sediments on concrete prior to coating − removes thick paint coatings or rust from steel surfaces, bridges, tanks, etc. − removes flexible coatings on parking house decks − removes road markings and retexturing of asphalt and concrete roads Media nr. 8 Only as an addition to Media No. 3, No. 4 and No. 5 with maximum 30% content. Media No. 8 should never be used without blending since otherwise the wear in the machine as a whole would increase disproportionately. − removes polyurethane coatings − removes adhesive remnants − removes rubber deposits − penetrates coatings hard to remove − also suitable to be used on steel for extraordinary roughness

10

Operating manual 1-10DPS75

11/12

7. Technical data 1-10DPS75 Power consumption blastwheel motor Electrical connection (voltage is given on the control box)

7,5 kW

Blast width

3x230V / 60 Hz 400V / 50 Hz 400V / 60 Hz Power supply must have a circuit breaker with Dcharacteristic 254 mm

Drive speed

0 – 30 m/min

Max. blast cleaning output on concrete Abrasive consumption Length

120 m²/h



I>

I>

thermostaat hygrostaat

Resistor / Heating

weerstand verwarming

Socket

wandcontactdoos

drukschakelaar ˜ -

+ ˜

Limit switch

8

transformator

Contactor/relay coil, with pick-up delay

Pressure switch

7

urenteller

drukknop terugverend

Thermostatic switch

6

amperemeter

Contactor coil relay coil

Pushbotton locking

P

5

auxiliary contact

NO contact, closes with time delay

P

4

eindschakelaar

Current transformer Proximity switch

stroomtransformator

naderingsschakelaar

3

Modification

5

Date

Name

Date 9-3-2011 Ed. Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Symbol library

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

4

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

300 mm 250 mm

10T4 10L2 12S1

12V2

Max. Speed

12SH1

400 mm

11S4.1

Reverse Speed

Vario speed

11S5 11R2

11U1

370 mm

10V2

10Q2

10F4

11S4 Trigger Drive

10F6

10F4.1 10Q0

Mainswitch in door 10Q0

12K1

Cable Drive motor

Earth conn. to frame

Cable blast motor

Cable Power supply

4x Blind rivet nut M8

Cable controller

4

Modification

6

Date

Name

Date 16-9-2015 Ed. KR Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Panel block diagram

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

5

© ART4 Technical Systems, Soest NL

0

1

2

3

LEFTHAND

4

5

6

7

220 212

220 mm

170

115

128

55

20

9

MOUNTING PLATE All holes M4

FRONT VIEW

VIEW

8

115

75

7

400

260

230

104 88

190

2

ø2

215

95

165

120

130 45

120

35

60

45

18

,5 Ø6 ,5 Ø6

2

ø2

75

36

70

ø5

48

150

65

100

48

ø13

4

300

30 75

242

50

45

30

30

170 180

50 87

53.5

140

220 230

Power Supply M32 Blastmotor M32

Wheelmotor M20 Control unit M16 Earth M16

5

Modification

7

Date

Name

Date 11-11-2014 Ed. PH Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Panel layout

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

6

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Motor side Cabinet Side

GND = GREEN U1 4 = RED V1 9 = WHITE W1 14 = BLACK 150

100

Blast motor (total length 160cm)

U1

X1:1 X1:2 X1:3 PE

V1

Neopreen 4x4mm2 (AWG12)

Yellow M5

W1 Wire ferrules 1350

PE

1600

Motor side GND = GREEN U1 25 = RED V1 26 = WHITE W1 27 = BLACK

Cabinet Side 150

100

Drive motor (total length 75cm)

U1

X2:1 X2:2 X2:3 PE

Neopreen 4x1,5 mm2 (AWG16)

V1

Red M5

W1 Wire ferrules 500

PE

750

Unit side

Cabinet Side Trigger switch (total length 135cm)

100

100

100

Brown Green White

POTMETER LEFT

Wire ferrules

Mantel X3:3 X3:2 X3:1 X3:4 X3:5 X3:6 X3:7

100

Brown

3x0,5 mm2 (AWG22) afgeschermd

Green White

Rear view

MID RIGHT

71 73 75 76

4xAWG18 DARK BLUE Wire ferrules

Slang SP16 950

SP16/M16A

SP16/M16B

1350

6

Modification

10

Date

Name

Date 16-10-2012 Ed. Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Cable set

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

7

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

1 6

BK AWG10

BK AWG10

11 BK AWG10

2

10Q0

4

5

10Q2

6

24...32A Ith=28A

5

I>

I>

I>

2

4

6

80A/15Hp

13

21

13

2

4

6

14

22

14

BK AWG14

15

5

3

BK AWG14

5

12.1

3

3

5

C10A 1 1

1

10F4 10

6

1

11

10 15

15

5

BK AWG16

L1 / 11.0 L2 / 11.0 L3 / 11.0

X1

C2A

2

4 17

AWG 18 BK AWG10

12

7

3

16

x2 BK AWG16

BK AWG10

2

1

10F6

3

X2

x1

10L2

13

A

8

10V2

1

3

5

10T4

12K1 12.1

2

4

160VA

6

6 230V

4

1

PE

8

230V

BK AWG10

L3

PE

0V(32)

1PE

14

9

4

24V(31)

PE

PE

1PE

L2

1PE

L1

1PE

X0

PE

1PE

PE

1PE

PE

PE

18

8 AWG

L2

L3

PE

PE

Earth connection to Frame

10M2 10Hp

W1

PE

1PE

V1

1

M

10F4.1

3

C4A

2

24

U1 L1

19

PE

Power supply 230V 3ph 60Hz

Blast motor 10Hp/230V/26.5A Connection in Delta

RD AWG18

24VN / 12.0 24V / 12.0 Control Voltage 24Vac 60Hz

7

Modification

11

Date

Name

Date 17-7-2014 Ed. HvdB Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Main Current

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

10

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

10.8 / L1 10.8 / L2 10.8 / L3 71 BK AWG14

x2

11R2

13 x3

11S4

71

x1

14

11S4.1

X3

GN

BN

1

2

3

Backside 11R2

11S5

14

75

FWD REV

5

6

28 29 BROWN 30 WHITE GREEN

7

73

12S1 12 32

30

29

28

12.1

76

11

PE

75

1PE 10

13

DBU AWG22

PE

1PE 5

4 71

PE

WT

14

Overdrive 73

Drive

13

76

Vario speed

X2

71

DBU AWG22

15

11U1 PE

U

V

W

PE

7

8

9

20

E1

E2

GNYE AWG16

1PE

BK AWG16

28

SETTINGS LENZE ESMD C02 2 C12 2.5 sec. C13 2.5 sec. C37 60Hz

27

L3

26

L2

25

L1

U1

11M1 0,5Hp

V1

PE

1PE

3

27

2

26

1

25

X2

W1

PE

M 3 0.5Hp/230V/1.84A Connect as DELTA

Wheel motor

Speed

Supply and EMS

Drive

Overdrive

FWD/REV

10

Modification

12

Date

Name

Date 30-6-2014 Ed. PH Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Main Current

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

11

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

RD AWG18

19

10.7 / 24V

21

12S1 11.3 Emergency stop

22

20

20

3

13

12K1

12SH1 12.1 12.2 ON

12.1

14

21

4

21

21

12SH1 12.1 OFF

22

22

13

10Q2 10.2 23

14

23

23

1 A1

X1

12K1 24Vac

10.7 / 24VN

12SH1 12.1 24V

A2

24

24

1 3 5 13 21

2 4 6 14 22

12V2 X2

Hour counter 60Hz

h 2

24

10.2 10.2 10.2 12.2

Control Voltage ON

Hours Run

11

Modification

20

Date

Name

Date 14-4-2015 Ed. HvdB Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Control Current

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

12

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Terminal diagram

F13_001

Cable name

Cable name

Strip

X0 Terminals Power supply

Target designation

cable type

Connection point

jumper

terminal

Connection point

cable type

function text

Target designation

Page / column

Power supply 230V 3ph 60Hz

10Q0

2

L1

L1

10.0

=

10Q0

4

L2

L2

10.0

=

10Q0

6

L3

L3

10.0

=

PE

PE

PE

10.1

=

PE

PE

PE

10.1

Blast motor 10Hp/230V/26.5A Connection in Delta

PE

PE

PE

10.2

10M2

12

Modification

22

Date

Name

Date 14-11-2012 Ed. Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Terminal Diagram

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

20

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Terminal diagram

F13_001

Cable name

Cable name

Strip

X2 Terminals Controler

Target designation

Wheel motor

11U1

= =

cable type

Connection point

jumper

terminal

Connection point

cable type

function text

Target designation U

1

11M1

11U1

V

2

11U1

W

3

=

11U1

PE

=

11U1

PE

Page / column U1

11.1

11M1

V1

11.1

11M1

W1

11.1

PE

11M1

PE

11.1

PE

PE

11.1

20

Modification

23

Date

Name

Date 12-1-2012 Ed. HvdB Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Terminal Diagram

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

22

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Terminal diagram

F13_001

Cable name

Cable name

Strip

X3

Target designation

cable type

Connection point

jumper

terminal

Connection point

cable type

function text

Target designation

Page / column

Speed

11U1

7

1

11R2

x1

11.2

=

11U1

8

2

11R2

x3

11.2

=

11U1

9

3

11R2

x2

11.3

Supply and EMS

12S1

11

4

11S4

13

11.3

Drive

11U1

28

5

11S4

14

11.4

Overdrive

11U1

E1

6

11S4.1

14

11.4

FWD/REV

11U1

E2

7

11S5

14

11.5

22

Modification

30

Date

Name

Date 12-1-2012 Ed. HvdB Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Terminal Diagram

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

23

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Parts list device tag

Quantity 1 1 1 160 1 1 1 1 1 1 4 1 1 3 1 1 1 4 2 2 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB CAB PG1 PG1 PG2 PG2 PG4 PG4 PG5 PG5 PG3 PG3 10Q0 10Q0 10V2 10Q2 10Q2 10L2 10T4 10F4 10F6 10F4.1 11U1 11R2 11R2 11R2 11S4 11S4.1 11S5 12S1 12S1 12S1 12SH1 12SH1 12SH1 12SH1 12SH1

designation Wall mount encl 400*300*150 IP66 overdrive-forward zelfkl.60*10 witte pl/zw letter speed control zelfkl.45*10 witte pl/zw letter Label for ader 12*12 Brady 7000pcs. p/r Mount.drain BxH 25x60 MM vpp=60 M.rail galvanized,7,5x35MM 2M FITTING @16*M16 vast FITTING @16*M16 DRAAIBAAR Beschermslang metaal + pvc 16*13 zwart Cable gland nut M20*1.5 brass, nickel-plated Internal wire yellow/green AWG10 6mm2 UL-CSA Internal wire black AWG10 6mm2 UL-CSA Internal wire yellow/green AWG14 2.5mm2 UL-CSA Internal wire black AWG14 2.5mm2 UL-CSA Internal wire yellow/green AWG16 1.5 mm2 UL-CSA Internal wire black AWG16 1.5mm2 UL-CSA UL neopreen 4*AWG16 (1.5mm2) 600V. Internal wire darkblue AWG22 0.5mm2 UL-CSA PVC 3*0.5 + afscherm. wi-br-gr UL neopreen 4*AWG12 (2.5mm2) 600V. Blindklinkmoer cilinderkop M8x16 staal elvz Cable gland M32*1.5 (PG21/29) brass, nickel-plated Cable gland nut M32*1.5 brass, nickel-plated Cable gland M32*1.5 (PG21/29) brass, nickel-plated Cable gland nut M32*1.5 brass, nickel-plated Cabel gland M16*1.5 (PG9/11) IP68 brass, nickel-plated 50616 Cable gland nut M16*1.5 brass, nickel-plated Cabel gland M16*1.5 (PG9/11) IP68 brass, nickel-plated 50616 Cable gland nut M16*1.5 brass, nickel-plated Cabel gland M20*1.5 (PG11/13.5/16) brass, nickel-plated Cable gland nut M20*1.5 brass, nickel-plated Body 3p main switch 80A Rotary handle front KCF - for V3, V4 - red handle Amperemeter 0..40/80/5A 48vk Faget Motor protection switch 24,0 32,0A Plug in aux. front for GV2-ME 1xNO +1xNC Tr.str.prim.40A,sec.5A Transformer Sitas 160VA 480V 550..208V/24V UL/CSA Circuit breaker AB 3P 10A C-kar UL 489 480/277V Circuit breaker AB 2P 2A C-kar UL 489 480/277V Circuit breaker AB 1P 4A C-kar ESMD371x2TXA basis Potm. 10KOhm. 4W-500V Head Ø22 + mounting base for potentiometer Schroef aansluiting potmeter Limit switch XCKP - steel roller plunger - 1NO+1NC - snap White square flush complete pushbutton Ø16 spring return 1NO White square flush complete pushbutton Ø16 spring return 1NO Sticker emergency stop yellow/red Red Ø40 Emergency switching off pushbutton head Ø22 latching Body for control button - Ø 22 - 2NC White light block with body/fixing collar integral LED 24V Green flush/red flush illuminated double-headed pushbutton Ø Single contact block for head Ø22 1NO screw clamp terminal Single contact block for head Ø22 1NC screw clamp terminal Transparent boot for rectangular multiple-headed pushbutton

Brand

Type number MAS 0403015 RESOPAL 2-20DT/1 RESOPAL 2-20DT/2 BPT-305-427 T1-E 25X60 MOUNT.DRAIN TS35 MOUNT.RAIL GROOVE SP16/M16/A SP16/M16/B SP16/ZWART WARTELMOER M20*1.5 AWG 10 GE/GR AWG 10 ZW AWG 14 GE/GN AWG 14 ZWART AWG 16 GN/GE AWG 16 ZWART AWG 16*4 AWG 22 D BL. STUURSTROOMKAB3*0.5 AWG 12*4 POPBC-1Z-M8X16 CK16 WARTEL M32*1.5 WARTELMOER M32*1.5 WARTEL M32*1.5 WARTELMOER M32*1.5 WARTEL M16*1.5 WARTELMOER M16*1.5 WARTEL M16*1.5 WARTELMOER M16*1.5 WARTEL M20*1.5 WARTELMOER M20*1.5 V4 KCF-2PZ IQ/EQ48 40/80/5A GV2-ME32 GV-AE11 IBA 40/5A SIEM 4AM3842-8DN00-0EA0 C60N-1489-M3C100 C60N-1489-M2C020 C60N-1492-SPM1C040 FREQ.REG 0.37 KW BAS 3*230V POTMETER 10 K OHM ZB5-AD912 POTMETER PRINT KLEM XCK-P2102P16 XB6-CA11B XB6-CA11B EMERGENCY STOP STICKER ZB4-BS844 ZB4-BZ104 ZB5-AVB1 ZB5-AW7A3741 ZBE-101 ZBE-102 ZBA-710

Blastrac number

Eldon Generic Generic Brady Generic Generic Adaptaflex Adaptaflex Adaptaflex Jacob LAPP LAPP LAPP LAPP LAPP LAPP LAPP LAPP LAPP Generic Jacob Jacob Jacob Jacob Jacob Jacob Jacob Jacob Jacob Jacob Schneider Schneider Crompton Schneider Schneider

E05173 E07836 E07837 E07893 E07972 E07835 E05179 E05178 E00559 E00406_1 E07973 E07891 E07974 E07843 E07975 E07947 E10796 E08012 E07971 E07976 E07968 E00408 E00408_1 E00408 E00408_1 E00405 E00405_1 E00405 E00405_1 E00406 E00406_1 E00563 333-3486.02 009316-80 E01528 333-3455 E01566 E07940 E07970 E05159 E05112 E05142 454795 E01351/1 E05088 454796 E00867 E00867 E07832 E08437 E01333 333-3226 E07804 E05091 E05092 E05070

Electric Electric Electric Electric

Siemens Allen Bradley Allen Bradley Allen Bradley Lenze Generic Schneider Electric Wieland Schneider Electric Schneider Electric Schneider Electric De Vries Schneider Electric Schneider Electric Schneider Electric Schneider Electric Schneider Electric Schneider Electric Schneider Electric

23

Modification

31

Date

Name

Date 16-9-2015 Ed. KR Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Part list

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

30

© ART4 Technical Systems, Soest NL

0

1

2

3

4

5

6

7

8

9

Parts list device tag

Quantity 1 1 3 1 3 1 7 1

12K1 12V2 X0 X0 X2 X2 X3 X3

designation Contactor 15kw 400VAC coil 24VAC 1NO/1NC Hour counter 48*48mm 20-26VAC (60Hz) UL/CSA Conn.railkl. 6MM2 grijs Conn.aardkl. 6MM2 GE/GN wk6sl/u Conn. railkl. 4MM2 grijs WK4/U Aardkl. 4MM2 ge/gr WK4SL/u Conn. railkl. 4MM2 grijs WK4/U Aardkl. 4MM2 ge/gr WK4SL/u

Brand

Type number LC1-D32-B7 M242-159-G-24VAC 60HZ VU4-6 CONN.RAILKL. VUPE 4-6 CONN.AARDKL VU4-4 GRIJS CONN.R.K VUPE 4-4 CONN.AARDKL VU4-4 GRIJS CONN.R.K VUPE 4-4 CONN.AARDKL

Blastrac number

Schneider Electric

500-3398 E08241 E01331 E01329 E07829 E01197 E07829 E01197

Wieland Wieland Wieland Wieland Wieland Wieland

30

Modification

Date

Name

Date 16-9-2015 Ed. KR Appr Last print 16-9-2015

Project name:

1-10DPS 75 3PH-230-60HZ ULCSA E06206/ULCSA

Page description:

Customer:

Part list

Drawing number:

Blastrac bv PJ11.01066.08

= + Page

31

© ART4 Technical Systems, Soest NL

Certificate of Compliance Certificate:

2459264

Master Contract: 251963

Project:

2459264

Date Issued: December 1, 2011

Issued to:

ART4 Technical Systems B.V. Nieuwe gracht 11 3763 LP Soest THE NETHERLANDS

The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only Issued by: G. Vertechy G. Vertechy

PRODUCTS CLASS 3211 07 CLASS 3211 87

INDUSTRIAL CONTROL EQUIPMENT – Miscellaneous Apparatus INDUSTRIAL CONTROL EQUIPMENT – Miscellaneous Apparatus – Certified to US Standards

Motor control box, enclosure Type 1 Model 350E SB UL, 480Y/277 V, 30 A, 18 Hp, 3-ph, 60 Hz, SCCR 5kA Model 500E SB UL, 480Y/277 V, 45 A, 29 Hp, 3-ph, 60 Hz, SCCR 5kA Model BDC 854, 480Y/277 V, 62 A, 40 Hp, 3-ph, 60 Hz, SCCR 5kA Model 654 BDC, 480Y/277 V, 36 A, 27 Hp, 3-ph or 230 V, 72 A, 27 Hp, 3-ph, 60 Hz, SCCR 5kA Model 1-10DS Dual Voltage, 480Y/277 V, 19 A, 16 Hp, 3-ph or 230 V, 38 A, 16 Hp, 3-ph, 60 Hz, SCCR 5kA Model 1-15DS Dual Voltage, 480Y/277 V, 26 A, 21 Hp, 3-ph or 230 V, 52 A, 21 Hp, 3-ph, 60 Hz, SCCR 5kA Model 1-8 DPS30, 230V, 14 A, 4.3 Hp, 1-ph, 60 Hz, SCCR 5kA Model 1-10 DPS75, 230V, 29 A, 10.5 Hp, 3-ph , 60 Hz, SCCR 5kA Model BMC-EHY335, 480Y/277 V, 25 A, 17 Hp, 3-ph, 60 Hz, SCCR 5kA Note: - The motor control boxes are factory installed on industral floor treatment equipment. The suitability of the combination is to be determined by CSA-International or other NRTL.

FF0 002

DQD 507 Rev. 2009-09-01

Page 1

Certificate: Project:

2459264 2459264

Master Contract: 251963 Date Issued: December 1, 2011

APPLICABLE REQUIREMENTS CSA Standard C22.2 No. 0 CSA Standard C22.2 No. 04 CSA Standard C22.2 No. 14 UL508 UL508A

DQD 507 Rev. 2009-09-01

-

General Requirements, Canadian Electrical Code Part II Bonding of Electrical Equipment Industrial Control Equipment Industrial Control Equipment Industrial Control Panels

Page 2

Supplement to Certificate of Compliance Certificate:

2459264

Master Contract: 251963

The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate.

Product Certification History Project

Date

2459264

December 1, 2011 Original cCSAus Certification of motor control boxes Types 350E SB UL, 500E SB UL, BDC 854, 654 BDC, 1-10DS dual voltage, 1-15DS dual voltage, 1-8 DPS30, 1-10 DPS75 and BMC-EHY335.

DQD 507 Rev. 2009-09-01

Description

Page 1

13201 North Santa Fe Avenue  Oklahoma City, OK 73114  Ph: 800-256-3440  F: 405-478-8608 blastrac.com

Product Warranty Standard Equipment Products: Blastrac warrants its Blastrac Standard Equipment Products against defects in quality of material and workmanship, under normal and proper use for a period of 1 Year from the date of delivery, as noted on the returned warranty registration card, or, in the case of Rental Fleet Machines, 180 Days from the date of assignment to Rental Fleet. This warranty is nontransferable and is extended to machines purchased and entered into the normal service of surface preparation by a recognized professional or qualified contractor. Blastrac makes this warranty only to the buyer who purchases the products directly from Blastrac or its Authorized Distributor. This warranty does not include expendable parts such as, but not limited to, blades, blast wheels, wear plates, liners, seals, and electrical components. All purchased parts utilized in the manufacture will be honored to the original manufacturer’s specified warranty. If the buyer does not return the warranty card or register the product online at www.blastrac.com within 30 days after taking delivery of Blastrac Standard Equipment Products, the warranty period is limited to 6 months from the date of delivery noted on shipping receipt.

Hand Tool Products: Blastrac warrants its BLASTRAC Hand Tool Products, including hand grinders and accessories, against defects in material and workmanship under normal and proper use for a period of 90 days from the date of delivery or, in the case of Rental Fleet Machines, from the date of assignment to a Rental Fleet. Blastrac makes this warranty only to the buyer who purchases the products directly from Blastrac or its authorized distributor. This warranty does not include expendable parts such as blades. If the buyer does not return the warranty card, or register online at www.blastrac.com within 15 days after taking delivery of Blastrac Hand Tool Products, the warranty period is limited to 30 days from the date of delivery noted on shipping receipt.

WARRANTY TERMS AND CONDITIONS: 1. Blastrac’s obligation under this warranty is limited to the replacement or repair, at Blastrac’s option, of products and does not include, labor, the cost of transportation, loss of operating time, or normal maintenance services. 2. This warranty does not apply to failure occurring as a result of abuse, misuse, negligence, corrosion, erosion, normal wear and tear, alterations or modifications made to products without the express written consent of Blastrac. 3. The buyer must submit all warranty claims no later than thirty (30) days after buyer becomes aware of the basis for any such claim, or should have become aware of the basis for any such claim in the exercise of reasonable diligence.

To return parts for warranty consideration, please call Blastrac Customer Service at 800-256-3440. Your customer service representative will obtain the necessary information to complete the Blastrac Returned Merchandise Authorization (RMA) Form. Blastrac will then send the RMA form to the customer authorizing the return of the parts for warranty evaluation. The parts must be received within sixty (60) days following the RMA origination date or the warranty claim will be denied. Once the parts are received they will be evaluated for warranty. If the customer cannot wait for the evaluation/replacement of the parts during this process, the customer must issue a new purchase order to Blastrac for the replacement parts before they can be shipped. Once the evaluation process is complete and parts are deemed a valid warranty claim, a credit will be issued against this invoice. 4. The buyer may not return Blastrac products without written authorization to do so through a Blastrac RMA. 5. Blastrac reserves the right to inspect and determine the scope of its warranty responsibilities for any returned Blastrac products. 6. Blastrac makes no warranty with respect to accessories it does not manufacture, including but not limited to, engines, motors, batteries, tires and all other parts. See component manufacture warranty. 7. Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obligation for such changes or improvements on previously sold products. 8. The above warranty conditions can only be altered by Blastrac. Blastrac must confirm alterations in writing for each specific transaction. 9. Blastrac reserves the right to modify this warranty for used or demo products on an individual transaction basis. Blastrac will include warranty modifications on its invoices for used or demo products. 10. BLASTRAC DOES NOT AUTHORIZE ANY PERSON, REPRESENTATIVE, SERVICE OR SALES OUTLET TO MAKE ANY WARRANTY DIFFERENT FROM THIS PRODUCT WARRANTY. 11. EXCEPT FOR ITS PRODUCT REPAIR OR REPLACEMENT OBLGATIONS DESCRIBED IN THIS PRODUCT WARRANTY, UNDER NO CIRCUMSTANCES SHALL BLASTRAC BE LIABLE TO THE BUYER, OR ANY OTHER PERSON, FOR ANY DIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE BLASTRAC PRODUCT, OR FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY CHARACTER, INCLUDING WITHOUT LIMITATIONS, DAMAGES FOR ANY LOSS OF GOODWILL, WORK STOPPAGE, OR ANY AND ALL OTHER COMMERCIAL DAMAGES OR LOSSES. 12. BLASTRAC MAKES NO OTHER PRODUCT WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. This Product Warranty Effective January 1, 2010.

Warranty Registration Notification

I M P O R TA N T !

TO THE DELIVERING DISTRIBUTOR OR END USER To ensure the proper warranty coverage is extended to the owner of this machine, fill in the necessary information below COMPLETELY and ACCURATELY and retain for your records. Go to www.blastrac.com and register online. Click on the Register icon in the left column of the homepage, and fill out the product registration form with the same information that will be recorded here. The warranty period will start upon the delivery date of the machine. The distributor or the end user must provide the machine warranty information when the machine is delivered. Registration of the machine will extend the warranty period from the recorded delivery date entered with product registration. Failure to comply will make any and all warranties on the equipment void after 6 months. OWNER / END USER’S REFERENCE INFORMATION Delivery Date _________________________ Delivering Distributor’s Name and Address _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ Signature of Delivering Distributor’s Representative

Machine Model No._____________________ Machine Serial No. _____________________ Modifications__________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________

Blastrac is a registered trademark of Blastrac,NA

Fold and Detach Here if Mailing

Warranty Registration

IMPORTANT! To ensure that your Blastrac® machine is covered under warranty, please provide the information recorded here by registering online at blastrac.com, or complete this page and fax to 866-485-1046, or if you prefer, detach and mail to:

Blastrac, 13201 North Santa Fe Avenue, Oklahoma City, OK 73114-9901 (Please print legibly)

Company _____________________________________________________________________ Address ______________________________________________________________________ City, State, & Zip _______________________________________________________________ Telephone No._____________________ Contact Person ______________________________ Date of Purchase___________________ Date Received ______________________________ Machine Model No. __________________________ Serial No. _________________________ Distributor Name _______________________________________________________________ End User Name _______________________________________________________________ End User E-mail _______________________________________________________________