AT-A-GLANCE INDUSTRY BEST COLOR
BIOLOGICAL LED
FIXTURE FEATURES
XICATO® XTM
BIOS SKYBLUETM
INSTALLATION
SDCM: 2 1 x 2 MacAdam Ellipses CCT: 2700, 3000, 3000 Vibrancy, 3500 and 4000 Kelvin CRI: 83 or 97 / Vibrancy L80: 50,000hrs
SDCM: 2 CCT: 3000, 3500 and 4000 Kelvin EML (equivalent melanopic lux) 0.7 to 0.9 Patented technology for circadian regulation and entrainment
2-7/8” ceiling cut out Attached driver box Tension spring wing Rotates in ceiling independent of driver for 360° New Construction or remodel ICAT: box enclosure available Chicago Plenum
624 DOWNLIGHT
624 WALL WASH
624 ADJUSTABLE
Delivered Lumens: 525(IC without Box), 700, 950 DIM: LUTRON/DALI/120V Phase Cut - page 3 Diffuse or Specular 36° or 54° cETLus WET Location
Delivered Lumens: 550(IC without Box), 725, 1000 DIM: LUTRON/DALI/120V Phase Cut - page 5 21° Asymmetric reflector for maximum wall coverage Secondary optic film to reach top of wall cETLus WET Location No Scallop
Delivered Lumens: 675(IC without Box), 900, 1200 DIM: LUTRON/DALI/120V Phase Cut - page 7 Diffuse or Specular 36° or 54° True 0-30° tilt
THE CHROMA SPEC ADVANTAGE
CIE 1931 CHROMA CHART
The ALPHABET Series has set the bar for LED quality of light over time, with the use of cold remote phosphor technology by XICATO® • • • • • •
Industry’s tightest color consistency 1 x 2 MacAdam Ellipses Color rendering options from >80 to >95 Vibrancy color saturating HiDef lighting color points CCT options from 2700K to 4000K Multiple lumen packages from 400 to 4000 lumens Industry’s first 5 Year NO COLOR SHIFT Warranty The ALPHABET Series lands on the curve where perfect color is found. Others stray, not taking the Y axis into account. This allows for green and pinks.
How to write your specification for the best color quality:
1
TYPE
Description
Manufacturer part
Specification
Fixture count
A1
LED Downlight
NU 624 Downlight
Downlight with 2” aperture, 950 delivered lumens, 3000K and 36º beam, wet rated. LED must be 1 x 2 MacAdam Ellipses with SDCM of 2. Warranty must include 5 year no color shift.
448
BIOS®: CIRCADIAN REGULATION SPEC The ALPHABET Downlights Biological Series featuring BIOS® is redefining Circadian Rhythm LED by providing high melanopic lux (EML) in a desirable color temperature. Patented SkyBlueTM technology provides spectrum important for circadian regulation and entrainment Ideal spectrum for daytime light exposure without sacrificing preferred color temperature Fills the “green gap” from traditional LED lighting Color Rendering between 85 and 90 (CCT dependent) Full CCT offering in 3000K, 3500K, 4000K, and 5000K Spectral output designed to offer maximum protection from dangerous “Blue Light Hazard” Each light engine is factory calibrated for consistent color point Contributes towards satisfying WELL BUILDING STANDARD circadian lighting specs
• • • • • • • •
Entrainment: noun Entrain: verb | en·train | \in-ˈtrān\ to determine or modify the phase or period of
Relative Power (W/nm)
Traditional 3500K
Relative Power (W/nm)
BIOS 3500K
380 400 420 440
460 480 500 520
540 560 580 600
620 640 660 680
700
720 740 760 780
380 400 420 440
Wavelength (nm)
460 480 500 520
540 560 580 600
620 640 660 680
700
720 740 760 780
Wavelength (nm)
WHAT DOES BIOS® SERIES FOR CIRCARDIAN REGULATION DO? Circadian Rhythm is the human body clock that operates critical functions including the production of testosterone, growth hormone, cortisol, and melatonin. These hormones have a direct influence on a body’s overall functionality in key areas including: • • • • •
Sleep Cognition Performance Alertness Metabolism
LIGHT IS THE STRONGEST TIME CUE FOR THE CIRCADIAN SYSTEM Light signals the body clock whether it is night or day and therefore if it should be awake, alert, restful or regenerative. Photobiologists discovered a light-sensitive protein in the eye’s retina called Melanopsin that detects intensity or changing levels of light. This photoreceptor projects to a different, non-visual part of the brain where our circadian clock is located. So when sunlight gets brighter in the morning, melanopsin becomes very active and triggers the brain’s body clock, or suprachiasmatic nucleus, to shift into an active day pattern.
BIOLOGICAL LIGHTING featuring BIOS® The spike at 490nm and suppressed Blue Hazard Zone at 440-470nm allows for enhanced performance, energy and focus to the occupants. Bio process entrainment for a true Circadian Rhythm alignment with minimal “Blue Light Hazard”, saving your eyes from Macular Degeneration. How to write your specification for BIOS® Series: TYPE
Description
Manufacturer part
Specification
Fixture count
A1
LED Downlight
NU 624 Downlight
Downlight with 2” aperture, min 950 delivered lumens, 3000k and 36 degree beam. LED must be 3000K with equivalent melanopic lux (EML) greater than 0.7
448
A2
LED Downlight
NU 624 Downlight
Downlight with 2” aperture, min 950 delivered lumens, 3000k and 36 degree beam. LED must be 3500K with equivalent melanopic lux (EML) greater than 0.8
448
A3
LED Downlight
NU 624 Downlight
Downlight with 2” aperture, min 950 delivered lumens, 3000k and 36 degree beam. LED must be 4000K with equivalent melanopic lux (EML) greater than 0.9
448
624 DOWNLIGHT - 2”
Driver Box
L1
2-7/8" Ceiling Cutout
L1
DRIVER BOX SIZE L2**
Dimming Option 0-10V LUD ELV/DALI
L1
2-1/2"
Driver Box
Dimming Conduit Knock-out
Line Voltage Conduit Opening
ICAT Available Plenum Clearance*
9” 7-1/8” 19” 17-1/8” 11-1/8” 9-1/8”
yes no yes
8” 18” 10”
4-7/8" 4-7/8"
Driver Box
The 624D Recessed 2” LED Downlight with Chroma technology provides energy efficient light using a cold remote phosphor LED by XICATO® for industry-best fixture-to-fixture color consistency. Offered with a 36° or 54º beam spread.
+83 CRI
*525 lm 700 lm 950 lm
Driver Box+98
2-7/8" Ceiling Cutout
Expandable from 14 3/16" to 26"
Delivered lumens 4-7/8"
DESCRIPTION
12-1/8"
Expandable from 14-3/16" to 26"
*Adequate plenum clearance is recommended when no above ceiling access is available for the installation or servicing of the driver box (non-IC or inherently IC versions). **Thermal protector used on the 700lm and 950lm standard construction and NCM option. ø 2-7/8"
CRI**
ø 2-7/8" 2-7/8" Ceiling Cutout 9.1W 9.3W Driver Box 12.2W 15.6W 16.6W 2-7/8" Ceiling Cutout
11-1/4"
LED: Patented Cold Remote Phosphor, XICATO® SDCM: 1 x 2 MacAdam Ellipse, +/- 50 Kelvin 2700K, 3000K, 3500K, or 4000K CRI: >80 - typically 83, >95 - typically 98 LIFE: 80% at 50,000 hrs based on LM-80 testing 5 year “no color shift” warranty
Mounting system to accommodate a ceiling thickness between 1⁄2” to 1-1/4”, with a ceiling cutout of 2-7/8”.
10" 15-3/4" 10" 15-3/4" 14-7/8" 14-7/8"
Driver Box Driver Box
2"
2" 10" J-Box 15-3/4" 14-7/8"
J-Box
Driver Box Low Voltage Connector Low Voltage Connector
2" J-Box
IC/AT BOX
IC/AT BOX
Follow the steps to specify your fixture, example: 624D -322 - SA36 - 80 - 120 - XTM
SERIES
LUMEN
APERTURE
COLOR TEMPERATURE
REFLECTOR & DEGREE CODE
CRI IC/AT CODE* BOX VOLTAGE CODE
LED
624D downlight
3 4 5
2 2”
2 3 3V 9 4
DA36 diffuse, 36º DA54 diffuse, 54º
80 95
XTM XTM BIOS BIOS
525 lm 700 lm 950 lm
80 CRI 95 CRI
120 120V 277 277V
SA36 specular, 36º SA54 specular, 54º
DIMMING CODE
OPTIONS CODE
LUD
ICAT IC/Air Tight - Chicago Plenum Box (max 1-1/8” ceiling thickness) NCM New Construction Mounting Frame WLC Wet Location Construction
Lutron Hi-Lume / Eco Bus Dimming Driver to 1% (120 / 277V) ELV Trailing Edge Dimmable to 10%, [NOT available for 700lm and 950lm Non-IC] DALI DALI Dimming dimmable to 0%
3
2700K 3000K 3000K Vibrant 3500K 4000K
ø 2-7/8"
7-1/8"
7-1/8" 11-7/8"
11-7/8"
1-3/8" 7-1/8" 1-3/8" 11-7/8" 1-3/8"
Low Voltage Connector
ORDERING CODE
ø 2-7/8"
ø 2-7/8"
8-5/8"
to 26" 14 3/16" fromfrom Expandable to 26" 14 3/16" Expandable 8-5/8" 8-5/8"
12-1/8" 12-1/8"
NEW CONSTRUCTION MOUNTING FRAME
ø 2-7/8"
11-1/4"
ETLus Listed to UL1598 (suitable for wet locations with lens) cETL Listed to CSA C22.2 #250.0 Chicago Plenum 525 lm is inherently IC; 700 lm and 950 lm are Non-IC. IC with IC/AT Box option. Made in the USA - meets the requirements of the Buy American provision within the ARRA ICAT meets ASTM-E283
Expandable from 14-3/16" to 26"
• • • • • •
to 26" 14-3/16" fromfrom Expandable to 26" 14-3/16" Expandable
LISTINGS
11-1/4" 11-1/4"
Electronic multi-voltage (120V or 277V driver). 120-277V available for inherently IC and ICAT option. Replaceable LED module with quick disconnects. Extruded aluminium heat sink. Optional ICAT Junction box listed for feed through wiring. 0-10V Dimming (to 5%) standard.
IC/AIRø TIGHT CHICAGO 2-7/8" PLENUM BOX ø 2-7/8"
Expandable from 14 3/16" to 26"
REFLECTOR Downlights are provided with computer designed, lamp specific, post Alzak anodized reflectors pure IC/ATof BOX aluminium (99.98%). Available in Specular aluminium (SA) and Diffused aluminium (DA) to provide glare and iridescence free performance.
ELECTRICAL / LED DRIVER
1-3/8"
Low Voltage CCT: Connector
12-1/8"
TRIM MOUNTING SYSTEM
8-5/8"
2-1/4" 10" *ICAT / Inherent IC reduces wattage by 1.9W 3-1/8" 2-1/4" 15-3/4" **Complies with Title 24 residential requirements with ICAT / Inherent IC 3-1/8" configurations 2" Fixture design allows for retro t applications, allowing installation from below ceiling. Light assembly 14-7/8" 2-1/4" with driver box is standard construction. 7-1/8" 3-1/8" J-Box Driver Box 11-7/8" LED PERFORMANCE
HOUSING
NOTES * 95 CRI is for 525lm and 700lm LEDs only
Dimming Condu Knock-out
Line Voltage Conduit Opening
1-1/2"
L2
2-1/4" 3-1/8"
1-1/2" 2-1/2"
4-7/8"
L2 Driver Box
POLAR CANDELA DISTRIBUTION LUMINAIRE: 36º Specular Reflector with Lens LAMP: 1300 lm, 3000K CCT, 80 CRI LAMP CAT: XICATO® XTM LED Module
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE: 20%
-0º H CD: 0
90º -0º H
CD: 0 122
90º 80º
122 243
80º 70º
243 365
70º 60º
365 487
60º
487 608
50º
608 730
VA: 0º
730
VA: 0º 10º Center Beam fc ILLUMINANCE
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60
LUMENS% 784.2 828.7 882.2
LAMP% 60.3% 63.7% 67.9%
LUMINAIRE 85.2% 90% 95.8%
0-90 0-180
920.5 920.5
70.8% 70.8%
100% 100%
1.0ft 2.0ft 1.0ft 3.0ft 2.0ft 4.0ft 3.0ft 5.0ft 4.0ft 6.0ft 5.0ft 7.0ft 6.0ft 8.0ft 7.0ft 9.0ft 8.0ft 9.0ft
10º
20º
30º
40º
20º
30º
40º
50º
Beam Width AT A DISTANCE
2471.0 fc Center Beam fc 617.8 fc 2471.0 fc 274.6 fc
0.6 ft Beam Width 1.2 ft 0.6 ft ft 1.7
617.8 154.4 fc fc 274.6 fc 98.8 fc
1.2 ft ft 2.3 1.7 2.9 ft ft
154.4 fc 68.6 fc 98.8 fc fc 50.4
2.3 3.5 ft ft 2.9 ft ft 4.0
68.6 38.6 fc fc 50.4 fc fc 30.5
3.5 4.6 ft ft 4.0 ft ft 5.2
38.6 fc Vert. Spread: 32.1º 30.5 fc
RCC%: RW%: RCR: 0 1 2 3 4 5 6 7 8 9 10
80 70 .84 .81 .77 .74 .71 .68 .65 .63 .61 .59 .57
50 .84 .79 .74 .70 .66 .63 .60 .57 .55 .53 .51
30 .84 .77 .71 .66 .62 .59 .56 .54 .52 .49 .48
70 0 .84 .75 .69 .64 .60 .56 .54 .51 .49 .47 .45
70 .82 .79 .75 .72 .70 .67 .64 .62 .60 .58 .56
50 .82 .77 .73 .69 .65 .62 .59 .57 .55 .53 .51
30 .82 .76 .70 .66 .62 .59 .56 .54 .51 .49 .48
50 0 .71 .67 .63 .60 .57 .55 .52 .50 .48 .47 .45
50 .79 .74 .70 .67 .64 .61 .58 .56 .54 .52 .50
30 .79 .73 .68 .64 .61 .58 .55 .53 .51 .49 .47
30 20 .79 .72 .67 .62 .59 .56 .53 .51 .49 .47 .45
50 .75 .72 .68 .65 .62 .60 .57 .55 .53 .52 .50
30 .75 .71 .67 .63 .60 .57 .55 .53 .51 .49 .47
10 20 .75 .70 .65 .61 .58 .55 .53 .51 .49 .47 .45
50 .72 .69 .66 .64 .61 .59 .57 .55 .53 .51 .49
30 .72 .68 .65 .62 .59 .57 .54 .52 .50 .48 .47
0 20 .72 .68 .64 .60 .57 .55 .52 .50 .48 .47 .45
0 .71 .67 .63 .59 .56 .54 .52 .49 .48 .46 .44
Photometics PRO 1.3.25 copyright 2003-2015 by jSoluctions, Inc. Reported data calculated from manufacturer’s data file, based on IES recommended methods
4.6 ft 5.2 ft
Vert. Spread: 32.1º
POLAR CANDELA DISTRIBUTION LUMINAIRE: 54º Specular Reflector with Lens LAMP: 1300lm, 3000K CCT, 80 CRI LAMP CAT: XICATO® XTM LED Module
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE: 20%
-0º H CD: 0
90º -0º H
CD: 0 122
90º 80º
122 243
80º 70º
243 365
70º 60º
365 487
60º
487 608 608 730 730
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60
LUMENS% 698.0 827.0 899.8
LAMP% 53.7% 63.6% 69.2%
LUMINAIRE 73.9% 87.6% 95.3%
0-90 0-180
944.2 944.2
72.6% 72.6%
100% 100%
1.0ft 2.0ft 1.0ft 3.0ft 2.0ft 4.0ft 3.0ft 5.0ft 4.0ft 6.0ft 5.0ft 7.0ft 6.0ft 8.0ft 7.0ft 9.0ft 8.0ft 9.0ft
50º
VA: 0º
10º
VA: 0º 10º Center Beam fc ILLUMINANCE
20º
30º
40º
20º
30º
40º
Beam Width AT A DISTANCE
1468.0 fc Center Beam fc 367.0 fc 1468.0 fc 163.1 fc
0.8 ft Beam Width 1.6 ft 0.8 ft ft 2.5
367.0 fc 91.8 fc 163.1 fc 58.7 fc
1.6 ft ft 3.3 2.5 ft 4.1 ft
91.8 40.8 fc fc 58.7 fc fc 30.0
3.3 4.9 ft ft 4.1 ft ft 5.7
40.8 22.9 fc fc 30.0 18.1 fc fc
4.9 6.6 ft ft 5.7 7.5 ft ft
22.9 fc Beam Spread: 44.6º 18.1 fc Beam Spread: 44.6º
6.6 ft 7.5 ft
50º
RCC%: RW%: RCR: 0 1 2 3 4 5 6 7 8 9 10
80 70 .86 .82 .78 .74 .70 .67 .64 .61 .58 .55 .53
50 .86 .80 .74 .69 .65 .61 .57 .54 .51 .49 .46
30 .86 .78 .71 .65 .60 .56 .53 .50 .47 .44 .42
70 0 .86 .76 .68 .62 .57 .53 .50 .47 .44 .42 .39
70 .84 .80 .76 .72 .69 .66 .63 .60 .57 .55 .52
50 .84 .78 .73 .68 .64 .60 .57 .54 .51 .48 .46
30 .84 .77 .70 .65 .60 .56 .52 .49 .47 .44 .42
50 0 .73 .68 .63 .58 .55 .51 .48 .46 .43 .41 .39
50 .81 .75 .70 .66 .62 .59 .55 .53 .50 .48 .45
30 .81 .74 .68 .63 .59 .55 .52 .49 .46 .44 .42
30 20 .81 .73 .66 .61 .56 .52 .49 .46 .44 .41 .39
50 .77 .73 .68 .64 .61 .57 .54 .52 .49 .47 .45
30 .77 .72 .66 .62 .58 .54 .51 .48 .46 .44 .41
10 20 .77 .71 .65 .60 .56 .52 .49 .46 .43 .41 .39
50 .74 .70 .66 .63 .59 .56 .53 .51 .49 .46 .44
30 .74 .69 .65 .61 .57 .54 .51 .48 .46 .43 .41
0 20 .74 .68 .63 .59 .55 .52 .48 .46 .43 .41 .39
Photometics PRO 1.3.25 copyright 2003-2015 by jSoluctions, Inc. Reported data calculated from manufacturer’s data file, based on IES recommended methods
0 .73 .67 .62 .58 .54 .50 .47 .45 .42 .40 .38
624 WALL WASH - 2”
4-1/2"
Driver Box
L1
Driver Box
L1
DRIVER BOX SIZE L2**
Dimming Option 0-10V LUD ELV/DALI
L1
Dimming Conduit Knock-out
Line Voltage Conduit Opening
ICAT Available Plenum Clearance*
9” 7-1/8” 19” 17-1/8” 11-1/8” 9-1/8”
yes no yes
8” 18” 10”
4-7/8" 4-7/8"
*Adequate plenum clearance is recommended when no above ceiling access is available for the installation or servicing of the driver box (non-IC or inherently IC versions). **Thermal protector used on the 700lm and 950lm standard construction and NCM option. Driver Box
DESCRIPTION
delivered lumens
The 624W Recessed 2” LED Wall Wash with Chroma technology provides energy efficient light using a cold remote phosphor LED by XICATO® for industry-best fixture-to-fixture color consistency.
*550 lm 725 lm 1000 lm
HOUSING
*ICAT / Inherent IC reduces wattage by 1.9W 3-1/8" 2-1/4" **Complies with Title 24 residential requirements with ICAT / Inherent IC 3-1/8" configurations
4-7/8"
2-7/8" Ceiling Cutout
LED: SDCM: CCT: CRI: LIFE:
REFLECTOR
10" 15-3/4" 10" 15-3/4" 14-7/8" 14-7/8"
Driver Box Driver Box
2"
2" 10" J-Box 15-3/4" 14-7/8"
J-Box
Driver Box Low Voltage Connector Low Voltage Connector
NEW CONSTRUCTION MOUNTING FRAME to 26" 14 3/16" fromfrom Expandable to 26" 14 3/16" Expandable 8-5/8" 8-5/8"
12-1/8"
12-1/8" 12-1/8"
ø 2-7/8"
11-1/4"
ETLus Listed to UL1598 (suitable for wet locations with lens) cETL Listed to CSA C22.2 #250.0 Chicago Plenum 525 lm is inherently IC; 700 lm and 950 lm are Non-IC. IC with IC/AT Box option. Made in the USA - meets the requirements of the Buy American provision within the ARRA ICAT meets ASTM-E283
Expandable from 14-3/16" to 26"
LISTINGS
Patented Cold Remote Phosphor, XICATO® 1 x 2 MacAdam Ellipse, +/- 50 Kelvin 2700K, 3000K, 3500K, or 4000K >80 - typically 83, >95 - typically 98 80% at 50,000 hrs based on LM-80 testing 5 year “no color shift” warranty
IC/AIRø TIGHT CHICAGO 2-7/8" PLENUM BOX ø 2-7/8"
11-1/4" 11-1/4"
ELECTRICAL / LED DRIVER Electronic multi-voltage (120V or 277V driver). 120-277V available for inherently IC and ICAT option. Replaceable LED module with quick disconnects. Extruded aluminium heat sink. Optional ICAT Junction box listed for feed through wiring. 0-10V Dimming (to 5%) standard.
to 26" 14-3/16" fromfrom Expandable to 26" 14-3/16" Expandable
Downlights are provided with computer designed, lamp specific, post Alzak anodized reflectors of pure aluminium (99.98%). Wall washers provided with post vacuum metalized UL-Makrolon.
2-1/4" 3-1/8"
2" J-Box
Low Voltage Connector
IC/AT BOX
ORDERING CODE
IC/AT BOX
Follow the steps to specify your fixture, example: 624W -429 - 95 - 120 - XTM
SERIES
LUMEN
APERTURE
COLOR TEMPERATURE
CRI CODE*
VOLTAGE CODE
LEDIC/AT BOX
624W wall wash
3 4 5
2 2”
2 3 3V 9 4
80 95
120 120V 277 277V
XTM XTM BIOS BIOS
550 lm 725 lm 1000 lm
80 CRI 95 CRI
DIMMING CODE
OPTIONS CODE
LUD
ICAT IC/Air Tight - Chicago Plenum Box (max 1-1/8” ceiling thickness) NCM New Construction Mounting Frame WLC Wet Location Construction
Lutron Hi-Lume / Eco Bus Dimming Driver to 1% (120 / 277V) ELV Trailing Edge Dimmable to 10%, [NOT available for 700lm and 950lm Non-IC] DALI DALI Dimming dimmable to 0%
5
2700K 3000K 3000K Vibrant 3500K 4000K
NOTES * 95 CRI is for 550 lm and 725 lm LEDs only
ø 2-7/8"
ø 2-7/8"
ø 2-7/8"
8-5/8"
TRIM MOUNTING SYSTEM
CRI**
2-7/8" Ceiling Cutout 9.1W 9.3W Driver Box 12.2W 15.6W 16.6W 2-7/8" Ceiling Cutout
LED PERFORMANCE
Mounting system to accommodate a ceiling thickness between 1⁄2” to 1-1/4”, with a ceiling cutout of 2-7/8”.
• • • • • •
2-1/4"
Driver Box+98
Expandable from 14 3/16" to 26"
Fixture design allows for retrofit applications, allowing installation from below ceiling. Light assembly with driver box is standard construction.
+83 CRI
7-1/8"
7-1/8" 11-7/8"
11-7/8"
Dimming Condu Knock-out
Line Voltage Conduit Opening
1-1/2"
L2
2-1/2"
3-1/8"
2-3/8"
2-7/8" Ceiling Cutout
1-1/2" 2-1/2"
L2 Driver Box
1-3/8" 7-1/8" 1-3/8" 11-7/8" 1-3/8"
POLAR CANDELA DISTRIBUTION LUMINAIRE: Wall Wash LAMP: 1300lm, 3000K CCT, 80CRI LAMP CAT: XICATO® XTM LED Module
-0º H
-90º H
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE: 20%
-45º H
CD: 0
90º -0º H
-90º H
-45º H
CD: 0 122
90º 80º
122 243
80º 70º
243 365
70º 60º
365 487
60º
487 608 608 730 730
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60
LUMENS% 448.6 648.5 879.5
LUMINAIRE 46.6% 67.3% 91.3%
0-90 0-180
956.8 956.8
99.3% 100%
1.0ft 2.0ft 1.0ft 3.0ft 2.0ft 4.0ft 3.0ft 5.0ft 4.0ft 6.0ft 5.0ft 7.0ft 6.0ft 8.0ft 7.0ft 9.0ft 8.0ft 9.0ft
50º
VA: 0º
10º
20º
VA: 0º 10º Center Beam fc ILLUMINANCE 704.4 fc Center Beam fc 176.1 fc 704.4 fc 78.3 fc 176.1 fc 44.0 fc 78.3 fc fc 28.2 44.0 fc fc 19.6 28.2 fc fc 14.4 19.6 fc fc 11.0
20º
30º
40º
30º
40º
Beam Width AT A DISTANCE
0.8 ft 1.7 ft Beam Width 1.7 ft 3.3 ft 0.8 ft 1.7 2.5 ft 5.0 ft ft 1.7 ft ft 3.4 2.5 ft ft 4.2 3.4 ft ft 5.1 4.2 ft ft 5.9 5.1 ft ft 6.8
14.4 fc 8.7 fc 11.0 fc Vert. Spread: 45.9º 8.7 fc
5.9 ft ft 7.6 6.8 ft Horiz. Spread: 79.6º 7.6 ft
Vert. Spread: 45.9º
Horiz. Spread: 79.6º
3.3 6.7 ft ft 5.0 ft ft 8.3 6.7 ftft 10.0 8.3 ftft 11.7 10.0 13.3 ft ft 11.7 15.0 ft ft 13.3 ft 15.0 ft
50º
RCC%: RW%: RCR: 0 1 2 3 4 5 6 7 8 9 10
70
80 70 1.19 1.11 1.03 .96 .90 .84 .79 .74 .69 .65 .62
50 1.19 1.07 .97 .88 .80 .73 .68 .62 .58 .54 .50
30 1.19 1.04 .92 .82 .73 .66 .60 .55 .51 .47 .43
0 1.19 1.01 .87 .76 .68 .61 .55 .50 .46 .42 .39
70 1.16 1.08 1.01 .94 .88 .82 .77 .72 .68 .64 .61
50 1.16 1.05 .95 .86 .79 .72 .67 .62 .57 .53 .50
30 1.16 1.02 .90 .80 .72 .65 .60 .55 .50 .47 .43
50 0 .99 .89 .79 .71 .64 .58 .53 .48 .45 .41 .38
50 1.11 1.01 .92 .84 .77 .70 .65 .60 .56 .52 .49
30 1.11 .98 .88 .78 .71 .64 .59 .54 .50 .46 .43
30 20 1.11 .96 .84 .74 .66 .60 .54 .49 .45 .42 .39
50 1.06 .97 .88 .81 .74 .68 .63 .59 .55 .51 .48
30 1.06 .95 .85 .77 .69 .63 .58 .53 .49 .46 .42
10 20 1.06 .93 .82 .73 .65 .59 .54 .49 .45 .41 .38
50 1.01 .93 .85 .78 .72 .67 .62 .57 .54 .50 .47
30 1.01 .92 .83 .75 .68 .62 .57 .52 .48 .45 .42
0 20 1.01 .90 .80 .72 .64 .58 .53 .49 .45 .41 .38
Photometics PRO 1.3.25 copyright 2003-2015 by jSoluctions, Inc. Reported data calculated from manufacturer’s data file, based on IES recommended methods
0 .99 .88 .78 .70 .63 .57 .51 .47 .43 .40 .37
624 ADJUSTABLE - 2”
Driver Box
2-7/8" Ceiling Cutout
L1
L2**
Dimming Option 0-10V LUD ELV/DALI
L1
2-1/2"
Driver Box
L1
Dimming Conduit Knock-out
Line Voltage Conduit Opening
ICAT Available Plenum Clearance*
9” 7-1/8” 19” 17-1/8” 11-1/8” 9-1/8”
yes no yes
8” 18” 10”
4-7/8" 4-7/8"
*Adequate plenum clearance is recommended when no above ceiling access is available for the installation or servicing of the driver box (non-IC or inherently IC versions). **Thermal protector used on the 700lm and 950lm standard construction and NCM option. Driver Box
DESCRIPTION
delivered lumens
The 624A Recessed 2” LED Adjustable Downlight with Chroma technology provides energy efficient light using a cold remote phosphor LED by XICATO® for industry-best fixture-to-fixture color consistency. Offered with a 36° or 54º beam spread.
*675 lm 900 lm 1200 lm
HOUSING
*ICAT / Inherent IC reduces wattage by 1.9W 3-1/8" 2-1/4" **Complies with Title 24 residential requirements with ICAT / Inherent IC 3-1/8" configurations
REFLECTOR
to 26" 14 3/16" fromfrom Expandable to 26" 14 3/16" Expandable 8-5/8" 8-5/8"
12-1/8"
12-1/8" 12-1/8"
NEW CONSTRUCTION MOUNTING FRAME
4-7/8"
ø 2-7/8"
10" 15-3/4" 10" 15-3/4" 14-7/8" 14-7/8"
Driver Box Driver Box
11-1/4"
ETLus Listed to UL1598 (suitable for wet locations with lens) cETL Listed to CSA C22.2 #250.0 Chicago Plenum 525 lm is inherently IC; 700 lm and 950 lm are Non-IC. IC with IC/AT Box option. Made in the USA - meets the requirements of the Buy American provision within the ARRA ICAT meets ASTM-E283
Expandable from 14-3/16" to 26"
• • • • • •
Patented Cold Remote Phosphor, XICATO® 1 x 2 MacAdam Ellipse, +/- 50 Kelvin 2700K, 3000K, 3500K, or 4000K >80 - typically 83, >95 - typically 98 80% at 50,000 hrs based on LM-80 testing 5 year “no color shift” warranty
IC/AIRø TIGHT CHICAGO 2-7/8" PLENUM BOX ø 2-7/8"
11-1/4" 11-1/4"
LISTINGS
to 26" 14-3/16" fromfrom Expandable to 26" 14-3/16" Expandable
Downlights are provided with computer designed, lamp specific, post Alzak anodized reflectors of pure aluminium (99.98%). Available in Specular aluminium (SA) and Diffused aluminium (DA) to provide glare and iridescence free performance.
2"
2" 10" J-Box 15-3/4" 14-7/8"
J-Box
Driver Box Low Voltage Connector Low Voltage Connector
2" J-Box
IC/AT BOX
IC/AT BOX
Follow the steps to specify your fixture, example: 624A -424 - DA54 - 95 - 277 - BIOS
SERIES
LUMEN
624A adjustable 3 4 5
675 lm 900 lm 1200 lm
APERTURE
COLOR TEMPERATURE
REFLECTOR & DEGREE CODE
CRI IC/AT CODE* BOX VOLTAGE CODE
LED
2 2”
2 3 3V 9 4
DA36 diffuse, 36º DA54 diffuse, 54º
80 95
XTM XTM BIOS BIOS
80 CRI 95 CRI
120 120V 277 277V
SA36 specular, 36º SA54 specular, 54º
DIMMING CODE
OPTIONS CODE
LUD
ICAT IC/Air Tight - Chicago Plenum Box (max 1-1/8” ceiling thickness) NCM New Construction Mounting Frame WLC Wet Location Construction
Lutron Hi-Lume / Eco Bus Dimming Driver to 1% (120 / 277V) ELV Trailing Edge Dimmable to 10%, [NOT available for 700lm and 950lm Non-IC] DALI DALI Dimming dimmable to 0%
7
2700K 3000K 3000K Vibrant 3500K 4000K
ø 2-7/8"
ø 2-7/8"
ø 2-7/8"
7-1/8"
7-1/8" 11-7/8"
11-7/8"
1-3/8" 7-1/8" 1-3/8" 11-7/8" 1-3/8"
Low Voltage Connector
ORDERING CODE
CRI**
2-1/4" 3-1/8"
8-5/8"
LED: SDCM: CCT: CRI: LIFE:
TRIM MOUNTING SYSTEM
Electronic multi-voltage (120V or 277V driver). 120-277V available for inherently IC and ICAT option. Replaceable LED module with quick disconnects. Extruded aluminium heat sink. Optional ICAT Junction box listed for feed through wiring. 0-10V Dimming (to 5%) standard.
2-7/8" Ceiling Cutout
2-7/8" Ceiling Cutout 9.1W 9.3W Driver Box 12.2W 15.6W 16.6W 2-7/8" Ceiling Cutout
LED PERFORMANCE
Mounting system to accommodate a ceiling thickness between 1⁄2” to 1-1/4”, with a ceiling cutout of 2-7/8”.
ELECTRICAL / LED DRIVER
2-1/4"
Driver Box+98
Expandable from 14 3/16" to 26"
Fixture design allows for retrofit applications, allowing installation from below ceiling. Light assembly with driver box is standard construction.
+83 CRI
NOTES * 95 CRI is for 675 lm and 900 lm LEDs only
Dimming Condu Knock-out
Line Voltage Conduit Opening
1-1/2"
L2
DRIVER BOX SIZE
1-1/2" 2-1/2"
L2 Driver Box
2-5/8"
3-1/8"
4-1/2" - 4-7/8"
0º - 30º
0º - 30º tilt
POLAR CANDELA DISTRIBUTION LUMINAIRE: 36º Adjustable LAMP: 1300lm, 3000K CCT, 80CRI LAMP CAT: XICATO® XTM LED Module
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE: 20%
-0º H CD: 0
90º -0º H
CD: 0 122
90º 80º
122 243
80º 70º
243 365
70º 60º
365 487
60º
487 608
50º
608 730
VA: 0º
730
VA: 0º 10º Center Beam fc ILLUMINANCE
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60
LUMENS% 958.4 1,130.4 1,167.3
LUMINAIRE 81.7% 96.4% 99.6%
0-90 0-180
1,172.4 1,172.4
100% 100%
1.0ft 2.0ft 1.0ft 3.0ft 2.0ft 4.0ft 3.0ft 5.0ft 4.0ft 6.0ft 5.0ft 7.0ft 6.0ft 8.0ft 7.0ft 9.0ft 8.0ft 9.0ft
10º
20º
30º
40º
20º
30º
40º
50º
Beam Width AT A DISTANCE
2456.0 fc Center Beam fc 614.0 fc 2456.0 fc 272.9 fc
0.7 ft Beam Width 1.3 ft 0.7 ft ft 2.0
614.0 153.5 fc fc 272.9 fc 98.2 fc
1.3 ft ft 2.6 2.0 3.3 ft ft
153.5 fc 68.2 fc 98.2 fc fc 50.1
2.6 3.9 ft ft 3.3 ft ft 4.6
68.2 38.4 fc fc 50.1 fc fc 30.3
3.9 5.2 ft ft 4.6 ft ft 5.9
38.4 fc Beam Spread: 36.2º 30.3 fc
RCC%: RW%: RCR: 0 1 2 3 4 5 6 7 8 9 10
70
80 70 1.19 1.14 1.09 1.05 1.00 .96 .92 .88 .85 .82 .79
50 1.19 1.12 1.05 .99 .94 .89 .84 .80 .77 .73 .70
30 1.19 1.09 1.01 .95 .89 .84 .79 .75 .71 .68 .65
0 1.19 1.07 .98 .91 .85 .80 .75 .71 .68 .65 .62
70 1.16 1.12 1.07 1.03 .99 .95 .91 .87 .84 .81 .78
50 1.16 1.09 1.03 .98 .93 .88 .84 .80 .76 .73 .70
30 1.16 1.07 1.00 .94 .88 .83 .79 .75 .71 .68 .65
50 0 1.00 .95 .90 .86 .81 .77 .73 .70 .67 .64 .61
50 1.11 1.05 1.00 .95 .90 .86 .82 .78 .75 .72 .69
30 1.11 1.04 .97 .92 .87 .82 .78 .74 .71 .67 .65
30 20 1.11 1.02 .95 .89 .84 .79 .75 .71 .67 .64 .61
50 1.06 1.02 .97 .93 .89 .85 .81 .77 .74 .71 .68
30 1.06 1.02 .95 .90 .85 .81 .77 .73 .70 .67 .64
10 20 1.06 .99 .95 .89 .84 .79 .75 .71 .67 .64 .61
50 1.02 .98 .94 .91 .87 .83 .80 .76 .73 .70 .68
30 1.02 .97 .93 .88 .84 .80 .76 .73 .70 .67 .64
0 20 1.02 .97 .91 .86 .82 .78 .74 .70 .67 .64 .61
0 1.00 .95 .90 .85 .80 .76 .72 .69 .66 .63 .60
Photometics PRO 1.3.25 copyright 2003-2015 by jSoluctions, Inc. Reported data calculated from manufacturer’s data file, based on IES recommended methods
5.2 ft 5.9 ft
Beam Spread: 36.2º
POLAR CANDELA DISTRIBUTION LUMINAIRE: 54º Adjustable LAMP: 1300lm, 3000K CCT, 80CRI LAMP CAT: XICATO® XTM LED Module
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE: 20%
-0º H CD: 0
90º -0º H
CD: 0 122
90º 80º
122 243
80º 70º
243 365
70º 60º
365 487
60º
487 608 608 730 730
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60
LUMENS% 807.2 1,083.4 1,195.3
LUMINAIRE 67.4% 90.5% 99.8%
0-90 0-180
1,197.3 1,197.3
100% 100%
1.0ft 2.0ft 1.0ft 3.0ft 2.0ft 4.0ft 3.0ft 5.0ft 4.0ft 6.0ft 5.0ft 7.0ft 6.0ft 8.0ft 7.0ft 9.0ft 8.0ft 9.0ft
50º
VA: 0º
10º
VA: 0º 10º Center Beam fc ILLUMINANCE
20º
30º
40º
20º
30º
40º
Beam Width AT A DISTANCE
1367.0 fc Center Beam fc 341.8 fc 1367.0 fc 151.9 fc
1.1 ft Beam Width 2.1 ft 1.1 ft ft 3.2
341.8 fc 85.4 fc 151.9 fc 54.7 fc
2.1 ft ft 4.3 3.2 ft 5.3 ft
85.4 38.0 fc fc 54.7 fc fc 27.9
4.3 6.4 ft ft 5.3 ft ft 7.5
38.0 21.4 fc fc 27.9 16.9 fc fc
6.4 8.5 ft ft 7.5 9.6 ft ft
21.4 fc Beam Spread: 56.1º 16.9 fc Beam Spread: 56.1º
8.5 ft 9.6 ft
50º
RCC%: RW%: RCR: 0 1 2 3 4 5 6 7 8 9 10
70
80 70 1.19 1.13 1.08 1.02 .97 .92 .87 .83 .79 .75 .71
50 1.19 1.11 1.03 .96 .89 .83 .78 .73 .69 .65 .61
30 1.19 1.08 .99 .91 .84 .78 .72 .67 .63 .59 .55
0 1.19 1.06 .95 .87 .79 .73 .68 .63 .59 .55 .52
70 1.16 1.11 1.06 1.00 .95 .90 .86 .81 .77 .74 .70
50 1.16 1.09 1.01 .94 .88 .82 .77 .73 .68 .64 .61
30 1.16 1.06 .97 .90 .83 .77 .72 .67 .63 .59 .55
50 0 1.00 .94 .87 .81 .76 .71 .66 .62 .58 .54 .51
50 1.11 1.04 .98 .92 .86 .81 .76 .71 .67 .64 .60
30 1.11 1.03 .95 .88 .82 .76 .71 .66 .62 .58 .55
30 20 1.11 1.01 .92 .85 .78 .72 .67 .62 .58 .55 .51
50 1.06 1.01 .95 .89 .84 .79 .74 .70 .66 .63 .59
30 1.06 .99 .92 .86 .80 .75 .70 .66 .61 .58 .55
10 20 1.06 .98 .90 .83 .77 .72 .67 .62 .58 .54 .51
20 1.06 .98 .90 .83 .77 .72 .67 .62 .58 .54 .51
30 1.02 .96 .90 .84 .79 .74 .69 .65 .61 .57 .54
0 20 1.02 .95 .88 .82 .76 .71 .66 .62 .58 .54 .51
Photometics PRO 1.3.25 copyright 2003-2015 by jSoluctions, Inc. Reported data calculated from manufacturer’s data file, based on IES recommended methods
0 1.00 .93 .87 .80 .75 .69 .65 .60 .56 .53 .50
RETROFIT / REMODEL / MOUNTING
• Accessible cETLus rated driver housing fits through fixture’s 2 7/8” cut out • Integrated thermal protection • Direct conduit elbow connection to the heatsink • 360º rotation of the fixture without driver box moving in the plenum space • IC rated Retrofit option offered
NEW CONSTRUCTION MOUNTING
• Galvanized steel, minimal plate construction • Premium mounting bars for limited movement • Simple sliding adjustment to cutout • Grid suspension, plaster or drywall ceiling
IC/AT CHICAGO PLENUM MOUNTING
• Galvanized steel construction • Air Tight Certified ASTM E283 • cETLus listed for direct contact w/insulation • CCEA Chicago Plenum
9
HARVARD CLK33 STANDARD 0-10V DIMMING - DIMMING FROM 100% TO 5% • Universal Input Voltage • Power factor corrected (0.95) • Constant current output • Up to 85% efficient • SELV isolation, Class 2
GE LIGHTECH™ ELV (TRAILING EDGE) - DIMMING FROM 100% TO 10% • Constant current output • Up to 89% efficient • Rated Lifetime of 50,000 hours
LUTRON® HI-LUME® A-SERIES L3D - DIMMING FROM 100% TO 1% Compatible with: • Energi Savr Node™ unit with • EcoSystem®, GRAFIK Eye® QS control unit, PowPak® dimming module with EcoSystem®, and Quantum® systems, allowing for integration into a planned or existing EcoSystem® lighting control solution • Standard 3-wire line-voltage phase-control technology for consistent dimming performance and compatibility with all • Lutron® 3-wire fluorescent controls. • Rated lifetime of 50,000 hours • FCC Part 15 compliant for commercial applications at 120 V~ or 277 V~.
ELDOLED® DALI ‘DIM TO DARK’ LED DRIVERS - DIMMING FROM 100% TO 0% • Hybrid HydraDrive: provides the smoothest flicker-free high-performance dimming to zero for every fixture • Lightshape: configurable dimming curve • Power factor @ full load >0.9 • LEDcode technology: configurable design to work with most constant current LED modules and arrays, while providing a connection point to integrated peripheral controls • NTC interface for robust thermal management • Wide application area thanks to fully configurable dimming curve
15774 GATEWAY CIRCLE TUSTIN, CA 92780 P 714.259.9959 F 714.259.9969
LEDRABRANDS.COM