N OTHI N G LE SS. N OT H I N G E LSE .
Nothing Less. Nothing Else. Think inverter ACs. Think Daikin.
100% copper coils in all models
Contents About Daikin and Daikin India
01
Inverter technology
02
R-32, a next-generation refrigerant
06
Product line up
08
Unit options
28
Feature list
30
About DAIKIN Daikin® is a leading innovator and provider of advanced, high-quality air-conditioning solutions for residential, commercial and industrial applications. As World’s No. 1 Air-conditioning Company, Daikin is committed to delivering air-conditioning solutions that enhance the quality of life all around the world. A diverse multinational company, Daikin Industries Ltd., active in air-conditioning, chemicals and oil hydraulics, was established in 1924. With headquarters at Osaka, Japan, the Daikin family has more than 51,000 members, working across 60 production base units and 208 consolidated subsidiaries worldwide. As the world’s sole manufacturer that develops a long line of products, from refrigerants to air-conditioners, Daikin advocates comfortable living on the strength of advanced technologies. Daikin is present in USA and Canada, Europe and Russia, Middle East, Africa, Central Asia, Southeast Asia, Oceania and Latin America. We aim to serve our customers in each of these markets by providing optimal air-conditioning products.
World’s No.
Daikin India at a glance 2000: Daikin enters the Indian market in a JV with Usha Shriram Group at 80:20 stakes respectively as Daikin Shriram Airconditioning. 2002: Daikin introduces VRV technology in India. 2004: Daikin India becomes a wholly owned subsidiary of Daikin Industries Ltd., Japan. 2007: Daikin India relocates HQ to Gurgaon and commences business of McQuay chillers in India. 2008: Groundbreaking ceremony of Daikin India’s manufacturing base at Neemrana, Rajasthan. 2009: Production commences at manufacturing plant in Neemrana, Rajasthan. 2010: Fresh round of Rs. 250 crore investment. Thus taking it to a total of Rs. 743 crore. 2012: Production of High Wall Split air-conditioners with R-32 refrigerant commences. 2013: Fresh round of Rs. 330 crore investment.
11 2
10
8
1
9 3
7
4
12
13 5 6
1. USA 2. Canada 3. Latin America 4. East Asia 5. Southeast Asia 6. Oceania 7. Africa 8. Central Asia 9. Middle East 10. Europe 11. Russia 12. Japan 13. India
What is Inverter Technology and how is it different from Non-Inverter Technology? An inverter is a device for converting frequency. The technology is used in many home appliances and controls electric voltage, current and frequency. Inverter air-conditioners vary their cooling/heating capacity by adjusting the power supply frequency of their compressors. An Inverter Type Air-Conditioner adjusts the speed of the compressor to control the gas
Inverter Technology
flow rate, thereby consuming less current and power. An inverter has precise temperature control and as the set temperature is attained, the unit adjusts its capacity to eliminate any temperature fluctuations. In contrast, non-inverter air-conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors.
Non-inverter air-conditioners stops and starts repeatedly. The power consumption and current goes down when the operation stops, but it goes up sharply at the time of restart and thus it has high average power consumption and temperature variations. As a result, inverter air-conditioners are more energy-saving and comfortable than non-inverter air-conditioners.
Variable capacity operation Inverter power control
Raise frequency
High-speed rotation
High capacity
Low-speed rotation
Low capacity
Compressor
Power Source Lower frequency
Non-inverter type air-conditioner Power Source
Compressor
Constant Speed rotation
Fixed Capacity
Inverter air-conditioners are able to vary their operating capacity. Non-inverter air-conditioners can only operate at a fixed capacity.
What are the benefits of Inverter Air-Conditioners? Powerful
Scenario: Indoor Temperature: 22°, Set Temperature: 22° Inverter air-conditioner
Inverter air-conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly.
Energy saving After the indoor temperature approaches the set temperature, inverter control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the room temperature.
22°
22°
22°
22°
Temperature remains constant
Non-inverter air-conditioner
Comfortable
21°
23°
Temperature rises and compressor starts again
v
23° v
Compressor stops
v
21° v
Inverter air-conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. This gives higher comfort level than the noninverter air-conditioners.
Temperature fluctuates
Compressor stops
Inverter air-conditioners are more comfortable than non-inverter models Diagrams is used for illustrative purpose only; actual conditions and scenario may vary from the one shown.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 02/03
The technology What is DC inverter?
DC motor for fan
Daikin calls an inverter model that is equipped with a DC motor as DC inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with power neodymium magnets, which enable even greater efficiency, is called a reluctance DC motor.
The DC motor allows fine rotation control, which reduces energy consumption. The motor also provides improvements in operational efficiency of up to 40%, compared to AC motor. These improvements are particularly noticeable in the low-speed range.
Efficiency of DC motor for fan* (comparison with a conventional AC motor)
Reluctance DC motor for compressor Daikin DC inverter models are equipped with the reluctance DC motor for compressor. The reluctance DC motor uses two different types of torque, neodymium magnet1 and reluctance torque2. This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. Daikin’s internally embedded neodymium magnet generates strong magnetic field and
100
Recipient of Electric Science Promotion Award (Reluctance DC motor for compressor)
Efficiency of Reluctance DC motor4
60
90
40 Approx. 40% increase
20
Approx. 20% increase
0 200 300 400 500 600 700 800 900 1000 Motor speed (rpm) DC motor
Motor efficiency (%)
Efficiency (%)
80
80
70
60
AC motor
*Data is based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.
More than 20%
50 0
30
60
90
120
Rotational speed (rps) Reluctance DC motor Conventional DC motor Small load
Large load Low capacity
AC motor High capacity
high torque resulting in high operational efficiency with less electricity consumption. It is more efficient at low frequencies most commonly used by air-conditioners3 improving efficiency by approximately 20%.
Swing compressor
Swing bush
Refrigerant gas
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
Pulse amplitude PAM control reduces energy loss by controlling how often the converter switches on and off
Integral piston of blade and roller The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor.
Sine wave
Neodymium magnets are used in the pink-coloured area.
Reluctance DC motor
Smooth sine wave of the inverter’s electric current eliminates pulsation and high harmonic noise. Highly effective inverter, that can generate the control signal which is closer to the sine wave, thus helping in better efficiency. .
Ferrite magnet
Neodymium magnet
1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. 2 The torque created by the change in power between the iron and magnet pads. 3 The frequency range used by air-conditioners during periods of stable operation. This is the range in which air-conditioners operate for the longest periods. 4 Data is based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.
Daikin was presented 32nd Chairman’s award by the Japan society for the promotion of the machine industry for swing compressor
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 04/05
R-32, a next generation refrigerant As part of its commitment to the environment, Daikin aims to develop systems that improve comfort levels, while having low environmental impact. Refrigerant choice is a key factor in the drive to maximise energy efficiency and to minimise the global warming impact of system.
R-32, a next generation refrigerant is the most balanced refrigerant for use in both residential and commercial air-conditioners.
Environmental impact ~1.6 times more cooling compared to R410A
~5% more power savings compared to R410A
~30% less refrigerant charging volume as compared to R410A & R22
Better performance at higher temperature as compared to R22 (Low Derating) Data based on studies conducted under test conditions
R-32 has zero Ozone Depletion Potential (ODP) and Modified Global Warming Potential (GWP) of 472, compared to R-410A’s Modified GWP of 2,027. Also R-32 is a single component refrigerant, which makes it easy to recycle. It is because of these reasons that R-32 offers the lowest total emissions and best overall life-cycle climate performance.
Theoretical Modified GWP 2,500
2,500
120 2,090
2,000
100
100
x
1,500 1,000 675
80
The potential refrigeration capacity of R-32 is 1.6 times that of R-22 and R-410A. More specifically the pressure loss is lower with R-32 than R-22 or R-410A for the same. The liquid density of R-32 is 10% lower thus the piping diameter can be smaller. As a result, the use of charging volume can be 30% less than R-22 or R-410A. The use of R-32 in the new Daikin range offers end-users the opportunity to benefit from class-leading energy efficiencies, excellent air quality and high comfort levels, while lowering the environmental impact of the refrigerants.
2,000 70
=
60 40
500 0
0
HCFC HFC HFC 22 410A 32
1,810
1,500 1,000 472
500
20
0
HCFC HFC HFC 22 410A 32
Charging ratio (%)
GWP
Better performance
2,027
97
1,810
HCFC HFC HFC 22 410A 32
Theoretical Modifide GWP
HFC32 is the most balanced refrigerant
Ozone
Ozone
Economy
5 4
5 4
3
3
3
3
1
HFC32
Ozone
5 4
2
Safety
Ozone
5 4
Economy
2
LCCP
Energy
1
Safety
HFC410A
LCCP
Energy
Economy
2 1
Safety
HFO1234YF
LCCP
Energy
Economy
2 1
Safety
LCCP
Energy
Propane (HFC290)
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 06/07
FTXR
Series Heat pump
PERFECTION IN AIR-CONDITIONING
Total comfort - Humidification, dehumidification, purification & ventilation
Ton: 0.75, 1.2, 1.5
Model Name Capacity
Inverter powerful operation - Boosts cooling/heating performance
Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate
Cooling breeze operation Comfortable cooling breeze
Mould proof stick - Prevents buildup of mould, bacteria and viruses
For the complete feature list please refer pages 30-31.
Fan Speed Sound Levels (H/M/L/SL) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels (H/SL) Dimensions (HxWxD) Machine Weight Operation range Max. Piping Length Max. Height Difference
Cooling Heating
Indoor Unit Outdoor Unit Rated (Min - Max) Rated (Min - Max)
Cooling Heating Cooling Heating Cooling Heating
Rated Rated (Min - Max) Rated
Cooling Heating Cooling Heating
Kw Kw
FTXR28KVMA RXR28KVMA 2.77 (1.55~3.60) 3.57 (1.30~5.00)
A A W W W/W W/W
3.3-3.2-3.1 4.0-3.9-3.8 570 (250~800) 710 (220~1410) 4.86 5.03 FTXR28KVMA
m³/min cfm m³/min cfm
11.1 392 12.4 438
dB (A)
39 / 33 / 26 / 23 41 / 35 / 28 / 25
mm kg RXR28KVMA Cooling Heating Cooling Heating
Type dB (A) mm kg °CDB °CWB m
46/-46/--
IDU Colour: White
FTXR42KVMA RXR42KVMA 4.20 (1.55~4.60) 5.08 (1.30~5.60) 1 phase, 220-240V, 50Hz 5.4-5.3-5.2 5.9-5.7-5.6 1070 (260~1320) 1170 (220~1600) 3.93 4.34 FTXR42KVMA White 12.4 438 12.9 455 5 steps, quiet and Automatic 42 / 35 / 27 / 24 42 / 36 / 29 / 26 305 x 890 x 209 14 RXR42KVMA Ivory White Hermetically sealed swing type 48/-48/-693 x 795 x 285 48 10°C to 43°C -20°C to 18°C (Humidify -10 to 24) 10 8
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, 24° CWB; piping length 7.5 m. 2. Heating capacity is based on: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB; piping length 7.5 m. 3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
FTXR50KVMA RXR50KVMA 4.88 (1.55~5.50) 5.91 (1.30~6.20) 7.2-7.1-7.0 7.3-7.2-7.1 1470 (260~1800) 1490 (230~1770) 3.32 3.97 FTXR50KVMA 13.3 470 14 494 44 / 37 / 29 / 26 44 / 38 / 31 / 28 RXR50KVMA 48/-50/--
FTXG
Series Heat pump
IT’S ALL ABOUT DESIGN
Indoor unit quite operation Cools/heats quietly
Ton: 0.75, 1, 1.4
Model Name Capacity
Comfortable mode - Provides gentle and comfortable environment
Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate
Cooling Heating
Indoor Unit Outdoor Unit Rated (Min - Max) Rated (Min - Max)
Cooling Heating Cooling Heating Cooling Heating
Rated Rated (Min - Max) Rated
Cooling Heating
Intelligent eye - Adjusts cooling according to human presence
Fan Speed Sound Levels (H/M/L/SL) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels (H/SL)
Saranet filter - Removes airborne dust particles for cleaner air supply
For the complete feature list please refer pages 30-31.
Dimensions (HxWxD) Machine Weight Operation range Max. Piping Length Max. Height Difference
Cooling Heating
Kw Kw A A W W W/W W/W m³/min cfm m³/min cfm dB (A) mm kg
Type Cooling Heating Cooling Heating
dB (A) mm kg °CDB °CWB m
IDU Colour: Sandblasted Aluminium
FTXG25JV1BA RXG25K3V1B 2.5 (1.3~3.0) 3.4 (1.3~4.5)
FTXG35JV1BA RXG35K3V1B 3.5 (1.4~3.8) 4.0 (1.4~5.0) 1phase, 220-240V, 50Hz 3.2-3.0-2.9 5.1-4.8-4.6 4.4-4.2-4.1 5.6-5.3-5.1 560 (350 - 820) 890 (360 - 1220) 780 (320 - 1320) 990 (320 - 1500) 4.46 3.93 4.36 4.04 FTXG25JV1BA FTXG35JV1BA Silver 8.8 10.1 311 357 9.6 10.8 339 389 5 steps, quiet and Automatic 38 / 32 / 25 /22 42 / 34 / 26 / 23 39 / 34 / 28 / 25 42 / 36 / 29 / 26 295 x 915 x 155 11 RXG25K3V1B RXG35K3V1B Ivory White Hermetically sealed swing type 46/43 48/44 47/44 48/45 550 x 765 x 285 34 -10°C to 46°C -15°C to 20°C 20 15
FTXG50JV1BA RXG50K3V1B 5.0 (1.7~5.3) 5.8 (1.7~6.5) 7.2-6.9-6.6 7.4-7.1-6.8 1560 (450 - 1880) 1600 (520 - 2500) 3.21 3.63 FTXG50JV1BA 10.3 364 11.4 402 44 / 40 / 35 / 32 44 / 40 / 35 / 32 RXG50K3V1B
735 x 825 x 300 48 30 20
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, 24° CWB; piping length 7.5 m. 2. Heating capacity is based on: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB; piping length 7.5 m. 3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 08/09
FTXS
Series Heat pump
BEYOND IMAGINATION
Intelligent eye - Senses human movement for temperature adjustment
Ton: 0.75, 1, 1.5, 1.8, 2.2
Model Name Capacity
3D airflow - Circulates a cloud of cool/warm air right to the corners of even large spaces
Running Current Power consumption
Indoor Unit Front panel Colour Airflow rate (H)
Sound Levels (H/L/SL)
Rated
A
Rated (Min.-Max)
W
Rated
W/W
Cooling Heating
m3/min(cfm)
Cooling Heating
dB (A)
Dimensions (HxWxD) Machine weight Outdoor Unit Casing colour Compressor
mm Kg
Type Cooling Heating
dB (A)
Cooling Heating
mm Kg ºCDB ºCWB m m
Dimensions (HxWxD) Machine weight Operation Range Max. piping length Max. height difference
For the complete feature list please refer pages 30-31.
Cooling Heating Cooling Heating Cooling Heating
Fan speed
Sound Levels (H/SL)
Inverter powerful operation Faster cooling/heating
Kw Kw
Power Supply
COP
Indoor unit quiet operation Quiet performance
Cooling Heating
Indoor Unit Outdoor Unit Rated (Min.-Max) Rated (Min.-Max)
FTXS25EVMA RXS25EBVMA 2.5 (1.2-3.0) 3.4 (1.2-4.5)
IDU Colour: White
FTXS35EVMA RXS35EBVMA 3.5 (1.2-3.8) 4.0 (1.2-5.0)
FTXS50FVMA FTXS60FVMA RXS50FVMA RXS60FVMA 5.0 (1.7-6.0) 6.0 (1.7-6.7) 5.8 (1.7-7.7) 7.0 (1.7-8.0) 1 phase, 230 V, 50Hz 3.3 4.7 6.9 8.8 4.1 4.9 7.1 9 600 (300-800) 1,020 (300-1,200) 1,550 (440-2,080) 1,980 (440-2,390) 830 (290-1,340) 1,080 (290-1,550) 1,600 (400-2,530) 2,040 (400-2,810) 4.17 3.43 3.23 3.03 4.10 3.70 3.63 3.43 FTXS25EVMA FTXS35EVMA FTXS50FVMA FTXS60FVMA White 8.7 (307) 8.9 (314) 14.7(519) 16.2(572) 9.4 (332) 9.7 (342) 16.2 (572) 17.4 (614) 5 steps, quiet and automatic 37 / 25 / 22 38 / 26 / 23 44 / 35 / 32 45 / 36 / 33 37 / 28 / 25 38 / 29 / 26 42 / 33 / 30 44 / 35 / 32 283 x 800 x 195 290 x 1,050 x 238 9 12 RXS25EBVMA RXS35EBVMA RXS50FVMA RXS60FVMA Ivory White Hermetically sealed swing type 46 / 43 47 / 44 49 / 46 47 / 44 48 / 45 49 / 46 550 x 765 x 285 735 x 825 x 300 34 48 10 to 46 -15 to 20 -15 to 18 20 30 15 20
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 7.5m. 2. Heating capacity is based on: indoor temp. 20º CDB; outdoor temp. 7º CDB, 6º CWB; piping length 7.5m. 3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
FTXS71FVMA RXS71FVMA 7.1 (2.3-8.5) 8.2 (2.3-10.0) 10.4 11.1 2,360 (570-3,200) 2,520 (520-3,730) 3.01 3.25 FTXS71FVMA 17.4(614) 21.5 (759) 46 / 37 / 34 46 / 37 / 34
RXS71FVMA
52 / 49 52 / 49 770 x 900 x 320 71
FTKM
Series Cooling only
PATH-BREAKING SERIES
Ton: 0.75, 1, 1.5, 1.8, 2.2
Stabiliser free operation - No extra cost
New smartphone connectivity feature (optional)
Indoor unit Outdoor unit
Model name
Coand airflow - Improves circulation of cold air
Power supply Power supply intake Cooling capacity
kW Btu/h Rated (min.~max.)
Intelligent eye - Senses human movement for temperature adjustment
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
For the complete feature list please refer pages 30-31.
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
IDU Colour: White
FTKM25QRV16 RKM25QRV16
FTKM35QRV16 RKM35QRV16
FTKM50QRV16 RKM50QRV16
FTKM60QRV16 RKM60QRV16
FTKM71QRV16 RKM71QV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 (1.0~3.2) 8500 (3400~10900) 650 (220~900) 3.85 (4.55~3.56) 3.07 FTKM25QRV16 White 283x800x198 8 (12) 9.6(8.5) 37/33/28/25 RKM25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 3.5 (1.0~4.0) 11900 (3400~13600) 964 (220~1300) 3.63 (4.55~3.08) 4.55 FTKM35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/34/29/26 RKM35QRV16 550x765x285 32(38) 48 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 5.0 (1.0~6.0) 17100 (3400~20500) 1315 (370~1700) 3.8 (2.70~3.52) 5.8 FTKM50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 42/38/35/28 RKM50QRV16 595x845x300 38(46) 47 R32) 10 30 20 12.7 / 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 6.0 (1.0~7.0) 20500 (3400~23900) 1666 (230~2250) 3.6 (4.35~3.11) 7.4 FTKM60QRV16 White 310x1100x239 13 (18) 18.1(15.1) 45/41/35/30 RKM60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.7 / 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 7.1 (2.1~8.0) 24200 (7200~27300) 2220 (530~3300) 3.2 (2.42~3.96) 9.6 FTKM71QRV16 White 310x1100x239 13 (18) 20.4(17.0) 46/42/36/32 RKM71QV16 735x825x300 49 (59) 52 R32 10 30 20 15.9 / 6.4 10~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 10/11
DTKM
Series Cooling only
PATH-BREAKING SERIES
Ton: 0.75, 1, 1.5, 1.8 New smartphone connectivity feature (optional)
Stabiliser free operation - No extra cost Indoor unit Outdoor unit
Model name
Power supply
New good sleep off timer Avoids excessive cooling and enjoy uninterrupted sleep
Cooling capacity
Intelligent eye - Senses human movement for temperature adjustment
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
For the complete feature list please refer pages 30-31.
Power supply intake kW Btu/h Rated (min.~max.)
Piping connection Operation limit
Cooling
W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
IDU Colour: White
DTKM25QRV16 RKMD25QRV16
DTKM35QRV16 RKMD35QRV16
DTKM50QRV16 RKMD50QRV16
DTKM60QRV16 RKMD60QRV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 (1.0~3.2) 8500 (3400~10900) 650 (220~900) 3.85 (4.55~3.56) 3.07 DTKM25QRV16 White 283x800x198 8 (12) 9.6(8.5) 37/33/28/25 RKMD25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 3.5 (1.0~4.0) 11900 (3400~13600) 964 (220~1300) 3.63 (4.55~3.08) 4.55 DTKM35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/34/29/26 RKMD35QRV16 550x765x285 32(38) 48 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 5.0 (1.0~6.0) 17100 (3400~20500) 1315 (370~1700) 3.8 (2.70~3.52) 5.8 DTKM50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 42/38/35/28 RKMD50QRV16 595x845x300 38(46) 47 R32 10 30 20 12.7 / 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 6.0 (1.0~7.0) 20500 (3400~23900) 1666 (230~2250) 3.6 (4.35~3.11) 7.4 DTKM60QRV16 White 310x1100x239 13 (18) 18.1(15.1) 45/41/35/30 RKMD60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.7 / 6.4 10~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
ATKM
Series Cooling only
PATH-BREAKING SERIES
Ton: 0.75, 1, 1.5, 1.8 New smartphone connectivity feature (optional)
Stabiliser free operation - No extra cost Indoor unit Outdoor unit
Model name
Power supply
Coand airflow - Improves circulation of cold air
Power supply intake Cooling capacity
kW Btu/h Rated (min.~max.)
Intelligent eye - Senses human movement for temperature adjustment
Silver particle anti-bacterial filter - Kills bacteria and deodorises the air
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
IDU Colour: White
ATKM25QRV16 RKMA25QRV16
ATKM35QRV16 RKMA35QRV16
ATKM50QRV16 RKMA50QRV16
ATKM60QRV16 RKMA60QRV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 (1.0~3.2) 8500 (3400~10900) 650 (220~900) 3.85 (4.55~3.56) 3.07 ATKM25QRV16 White 283x800x198 8 (12) 9.6(8.5) 37/33/28/25 RKMA25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 3.5 (1.0~4.0) 11900 (3400~13600) 964 (220~1300) 3.63 (4.55~3.08) 4.55 ATKM35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/34/29/26 RKMA35QRV16 550x765x285 32(38) 48 R32 10 20 15 9.5/ 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 5.0 (1.0~6.0) 17100 (3400~20500) 1315 (370~1700) 3.8 (2.70~3.52) 5.8 ATKM50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 42/38/35/28 RKMA50QRV16 595x845x300 38(46) 47 R32 10 30 20 12.7 / 6.4 10~46
1 50Hz 230V (220-240V) Outdoor unit 6.0 (1.0~7.0) 20500 (3400~23900) 1666 (230~2250) 3.6 (4.35~3.11) 7.4 ATKM60QRV16 White 310x1100x239 13 (18) 18.1(15.1) 45/41/35/30 RKMA60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.7 / 6.4 10~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
For the complete feature list please refer pages 30-31.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 12/13
FTKP
Series Cooling only
AIR-CONDITIONING REDEFINED
Ton: 0.75, 1, 1.5, 1.8, 2.2
Stabiliser free operation - No extra cost
New smartphone connectivity feature (optional)
Indoor unit Outdoor unit
Model name
Coand airflow - Improves circulation of cold air
Power supply Power supply intake Cooling capacity
Power chill operation - Quickly maximises the cooling
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
For the complete feature list please refer pages 30-31.
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
Rated (min.~max.)
FTKP25QRV16 RKP25QRV16
FTKP35QRV16 RKP35QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.5 (1.8~3.2) 3.4 (1.8~4.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3.46 (3.79~3.56) 3.46 (3.79~3.05) 3.49 4.74 FTKP25QRV16 FTKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9.6(8.5) 9.9(8.8) 37/33/28/25 40/36/31/26 RKP25QRV16 RKP35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9.5/ 6.4 9.5/ 6.4 19.4~46 19.4~46
FTKP50QRV16 RKP50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5.0 (2.5~5.7) 17100 (8500~19400) 1445 (710~1750) 3.46 (3.52~3.26) 6.5 FTKP50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 45/40/35/-RKP50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.7 / 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
FTKP60QRV16 RKP60QRV16
FTKP71QRV16 RKP71QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6.0 (2.5~6.7) 7.1 (2.1~7.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3.40 (3.47~3.02) 3 (3.50~2.42) 7.8 10.4 FTKP60QRV16 FTKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.1(15.1) 20.4(17.0) 47/43/38/-47/43/39/-RKP60QRV16 RKP71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12.7 / 6.4 15.9/ 6.4 19.4~46 19.4~46
DTKP
Series Cooling only
AIR-CONDITIONING REDEFINED
Ton: 0.75, 1, 1.5, 1.8, 2.2
Stabiliser free operation - No extra cost
New smartphone connectivity feature (optional)
Indoor unit Outdoor unit
Model name
New good sleep-off timer Avoids excessive cooling and enjoy uninterrupted sleep
Power chill operation - Quickly maximises the cooling
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
Rated (min.~max.)
DTKP25QRV16 RKPD25QRV16
DTKP35QRV16 RKPD35QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.5 (1.8~3.2) 3.4 (1.8~4.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3.46 (3.79~3.56) 3.46 (3.79~3.05) 3.49 4.74 DTKP25QRV16 DTKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9.6(8.5) 9.9(8.8) 37/33/28/25 40/36/31/26 RKPD25QRV16 RKPD35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9.5/ 6.4 9.5/ 6.4 19.4~46 19.4~46
DTKP50QRV16 RKPD50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5.0 (2.5~5.7) 17100 (8500~19400) 1445 (710~1750) 3.46 (3.52~3.26) 6.5 DTKP50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 45/40/35/-RKPD50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.7 / 6.4 19.4~46
IDU Colour: White
DTKP60QRV16 RKPD60QRV16
DTKP71QRV16 RKPD71QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6.0 (2.5~6.7) 7.1 (2.1~7.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3.40 (3.47~3.02) 3 (3.50~2.42) 7.8 10.4 DTKP60QRV16 DTKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.1(15.1) 20.4(17.0) 47/43/38/-47/43/39/-RKPD60QRV16 RKPD71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12.7 / 6.4 15.9/ 6.4 19.4~46 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 14/15
ATKP
Series Cooling only
AIR-CONDITIONING REDEFINED
Ton: 0.75, 1, 1.5, 1.8, 2.2
Stabiliser free operation - No extra cost
New smartphone connectivity feature (optional)
Indoor unit Outdoor unit
Model name
Econo mode - Reduces power consumption
Power supply Power supply intake Cooling capacity
Power chill operation - Quickly maximises the cooling
Silver particle anti-bacterial filter - Kills bacteria and deodorises the air
For the complete feature list please refer pages 30-31.
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Charge-less Max. length Max. height Gas/Liquid Cooling
m m m mm DB
Rated (min.~max.)
ATKP25QRV16 RKPA25QRV16
ATKP35QRV16 RKPA35QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.5 (1.8~3.2) 3.4 (1.8~4.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3.46 (3.79~3.56) 3.46 (3.79~3.05) 3.49 4.74 ATKP25QRV16 ATKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9.6(8.5) 9.9(8.8) 37/33/28/25 40/36/31/26 RKPA25QRV16 RKPA35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9.5/ 6.4 9.5/ 6.4 19.4~46 19.4~46
ATKP50QRV16 RKPA50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5.0 (2.5~5.7) 17100 (8500~19400) 1445 (710~1750) 3.46 (3.52~3.26) 6.5 ATKP50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 45/40/35/-RKPA50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.7 / 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
ATKP60QRV16 RKPA60QRV16
ATKP71QRV16 RKPA71QRV16
1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6.0 (2.5~6.7) 7.1 (2.1~7.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3.40 (3.47~3.02) 3 (3.50~2.42) 7.8 10.4 ATKP60QRV16 ATKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.1(15.1) 20.4(17.0) 47/43/38/-47/43/39/-RKPA60QRV16 RKPA71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12.7 / 6.4 15.9/ 6.4 19.4~46 19.4~46
FTKH
Series Cooling only
A NEW AGE OF AIR-CONDITIONING
Ton: 1.0, 1.5, 1.8
Stabiliser free operation No extra cost
New smartphone connectivity feature (optional)
Indoor unit Outdoor unit
Model name Power supply
Coand airflow - Improves circulation of cold air
Power chill operation - Quickly maximises the cooling
Cooling capacity Rated (min.~max.) COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length Piping connection Operation limit
Power supply intake
Charge-less Max. length Max. height Gas/Liquid
Cooling
kW Btu/h W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
IDU Colour: White
FTKH35QRV16 RKH35QRV16
FTKH50QRV16 RKH50QRV16
FTKH60QRV16 RKH60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.5 (1.75~3.5) 12000 (6000~12000) 3.0 (3.5~3.0) 5.1 FTKH35QRV16 White 283x800x198 8 (12) 9.9(8.8) 40/36/31/26 RKH35QRV16 550x765x285 26(33) 51/-R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.0 (2.5~5.0) 17100 (8550~17100) 3.0 (3.4~3.0) 7.32 FTKH50QRV16 White 310x1100x239 13 (18) 17.4(14.6) 45/40/35/-RKH50QRV16 595x845x300 34 (42) 54/-R32 10 20 10 12.7 / 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.0 (3.0~6.0) 20500 (10250~20500) 3.0 (3.4~3.0) 8.83 FTKH60QRV16 White 310x1100x239 13 (18) 18.1(15.1) 47/43/38/-RKH60QRV16 595x845x300 35(43) 56/-R32 10 30 20 12.7 / 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Econo mode - Reduces power consumption
For the complete feature list please refer pages 30-31.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 16/17
FTF
Series Cooling only
EXPERIENCE ELEGANCE IN AIR-CONDITIONING Stabiliser free operation - No extra cost
Ton: 1, 1.5, 1.8
Coand airflow - Improves circulation of cold air
Indoor unit Outdoor unit
Model name
Power supply Power supply intake Cooling capacity
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
Upto 50°C operating range Cools at high temperature* *Not applicable for 1.8 ton model
For the complete feature list please refer pages 30-31.
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
FTF35QRV16 RF35QRV16
FTF50QRV16 RF50QRV16
FTF60QRV16# RF60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 930 3.6 4.3 FTF35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/35/29 RF35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.7/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1445 3.6 6.6 FTF50QRV16 White 310x1100x239 13 (18) 18.1 (15.1) 44/41/35 RF50QRV16 595x845x300 44(54) 50 R32 10 20 10 15.9/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1880 3.4 8.6 FTF60QRV16# White 310x1100x239 13 (18) 20.4(17.0) 47/41/35 RF60QRV16 595x845x300 45(55) 56 R32 10 20 10 15.9 / 6.4 19.4~46 # 4 Star
DTF
Series Cooling only
EXPERIENCE ELEGANCE IN AIR-CONDITIONING Stabiliser free operation - No extra cost
Ton: 1 1.5, 1.8
Power chill operation - Quickly maximises the cooling
Indoor unit Outdoor unit
Model name
Power supply Power supply intake Cooling capacity
Titanium apatite photocatalytic air purifying filter - Absorbs bacteria and viruses and eliminates odor
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
Upto 50°C operating range Cools at high temperature* *Not applicable for 1.8 Ton model
For the complete feature list please refer pages 30-31.
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
IDU Colour: White
DTF35QRV16 RFD35QRV16
DTF50QRV16 RFD50QRV16
DTF60QRV16 RFD60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 930 3.6 4.3 DTF35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/35/29 RFD35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.7/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1445 3.6 6.6 DTF50QRV16 White 310x1100x239 13 (18) 18.1 (15.1) 44/41/35 RFD50QRV16 595x845x300 44(54) 50 R32 10 20 10 15.9/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1880 3.4 8.6 DTF60QRV16 White 310x1100x239 13 (18) 20.4(17.0) 47/41/35 RFD60QRV16 595x845x300 45(55) 56 R32 10 20 10 15.9 / 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 18/19
ATF
Series Cooling only
EXPERIENCE ELEGANCE IN AIR-CONDITIONING
Stabiliser free operation - No extra cost
Ton: 1, 1.5, 1.8
Coand airflow - Improves circulation of cold air
Indoor unit Outdoor unit
Model name
Power supply Power supply intake Cooling capacity
Silver particle anti-bacterial filter Kills bacteria and deodorises the air
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Upto 50°C operating range Cools at high temperature* *Not applicable for 1.8 ton model
For the complete feature list please refer pages 30-31.
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
ATF35QRV16 RFA35QRV16
ATF50QRV16 RFA50QRV16
ATF60QRV16 RFA60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 930 3.6 4.3 ATF35QRV16 White 283x800x198 8 (12) 9.7(8.6) 39/35/29 RFA35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.7/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1445 3.6 6.6 ATF50QRV16 White 310x1100x239 13 (18) 18.1 (15.1) 44/41/35 RFA50QRV16 595x845x300 44(54) 50 R32 10 20 10 15.9/ 6.4 19.4~50
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1880 3.4 8.6 ATF60QRV16 White 310x1100x239 13 (18) 20.4(17.0) 47/41/35 RFA60QRV16 595x845x300 45(55) 56 R32 10 20 10 15.9 / 6.4 19.4~46
FTC
Series Cooling only
EXTRA COMFORT, SUPERIOR COOLING
Stabiliser free operation - No extra cost
Ton: 0.75, 1.0, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Coand airflow - Improves circulation of cold air
Power chill operation - Quickly maximises the cooling
Econo mode - Reduces power consumption
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
IDU Colour: White
FTC25QRV16 RC25QRV16
FTC35QRV16 RC35QRV16
FTC50QRV16 RC50QRV16
FTC60QRV16 RC60QRV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 8500 770 3.25 3.4 FTC25QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RC25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1030 3.25 4.6 FTC35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RC35QRV16 550x765x285 31(39) 51 R32 10 20 15 9.5 / 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.22 17800 1605 3.25 7.3 FTC50QRV16 White 310x1100x258 13 (18) 18.1 (15.1) 44/41/35 RC50QRV16 595x845x300 39(49) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1970 3.25 9 FTC60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RC60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp.35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
For the complete feature list please refer pages 30-31.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 20/21
DTC
Series Cooling only
EXTRA COMFORT, SUPERIOR COOLING
Stabiliser free operation - No extra cost
Ton: 0.75, 1.0, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Econo mode - Reduces power consumption
Power chill operation - Quickly maximises the cooling
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
IDU Colour: White
DTC25QRV16 RCD25QRV16
DTC35QRV16 RCD35QRV16
DTC50QRV16 RCD50QRV16
DTC60QRV16 RCD60QRV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 8500 770 3.25 3.4 DTC25QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RCD25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1030 3.25 4.6 DTC35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RCD35QRV16 550x765x285 31(39) 51 R32 10 20 15 9.5 / 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.22 17800 1605 3.25 7.3 DTC50QRV16 White 310x1100x258 13 (18) 18.1 (15.1) 44/41/35 RCD50QRV16 595x845x300 39(49) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1970 3.25 9 DTC60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RCD60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
ATC
Series Cooling only
EXTRA COMFORT, SUPERIOR COOLING
Stabiliser free operation - No extra cost
Ton: 0.75, 1.0, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Coand airflow - Improves circulation of cold air
Power chill operation - Quickly maximises the cooling
Multi function filter - 99% efficiency against bacteria, virus and mildew
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) *1 Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
IDU Colour: White
ATC25QRV16 RCA25QRV16
ATC35QRV16 RCA35QRV16
ATC50QRV16 RCA50QRV16
ATC60QRV16 RCA60QRV16
1 50Hz 230V (220-240V) Outdoor unit 2.5 8500 770 3.25 3.4 ATC25QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RCA25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1030 3.25 4.6 ATC35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/29 RCA35QRV16 550x765x285 31(39) 51 R32 10 20 15 9.5 / 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.22 17800 1605 3.25 7.3 ATC50QRV16 White 310x1100x258 13 (18) 18.1 (15.1) 44/41/35 RCA50QRV16 595x845x300 39(49) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1970 3.25 9 ATC60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RCA60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 22/23
FTQ
Series Cooling only
EXPERIENCE NIRVANA
Stabiliser free operation - No extra cost
Ton: 1, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Coand airflow - Improves circulation of cold air
Power chill operation - Quickly maximises the cooling
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
FTQ35QRV16 RQ35QRV16
FTQ50QRV16 RQ50QRV16
FTQ60QRV16 RQ60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1100 3.05 4.9 FTQ35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/30 RQ35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1705 3.05 7.8 FTQ50QRV16 White 310x1100x258 13 (18) 18.5 (15.4) 45/41/35 RQ50QRV16 595x845x300 36(46) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 2100 3.05 9.6 FTQ60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RQ60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
DTQ
Series Cooling only
EXPERIENCE NIRVANA
Stabiliser free operation - No extra cost
Ton: 1, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Econo mode - Reduces power consumption
Power chill operation - Quickly maximises the cooling
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
IDU Colour: White
DTQ35QRV16 RQD35QRV16
DTQ50QRV16 RQD50QRV16
DTQ60QRV16 RQD60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1100 3.05 4.9 DTQ35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/30 RQD35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1705 3.05 7.8 DTQ50QRV16 White 310x1100x258 13 (18) 18.5 (15.4) 45/41/35 RQD50QRV16 595x845x300 36(46) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 2100 3.05 9.6 DTQ60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RQD60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 24/25
ATQ
Series Cooling only
EXPERIENCE NIRVANA
Stabiliser free operation - No extra cost
Ton: 1, 1.5, 1.8
Indoor unit Outdoor unit
Model name
Econo mode - Reduces power consumption
Power chill operation - Quickly maximises the cooling
Good sleep off timer - Avoids excessive cooling and enjoy uninterrupted sleep
For the complete feature list please refer pages 30-31.
Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length
Piping connection Operation limit
Cooling
kW Btu/h W W/W A
Cooling
mm kg m3/min. dBA
Cooling
mm kg dBA
Cooling
m m m mm DB
Rated
Charge-less Max. length Max. height Gas/Liquid
Measurement conditions: 1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35° CDB, 24° CWB; piping length 5m. 2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
IDU Colour: White
ATQ35QRV16 RQA35QRV16
ATQ50QRV16 RQA50QRV16
ATQ60QRV16 RQA60QRV16
1 50Hz 230V (220-240V) Outdoor unit 3.35 11450 1100 3.05 4.9 ATQ35QRV16 White 283x800x205 8 (12) 9.7(8.6) 39/35/30 RQA35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.5/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 5.2 17750 1705 3.05 7.8 ATQ50QRV16 White 310x1100x258 13 (18) 18.5 (15.4) 45/41/35 RQA50QRV16 595x845x300 36(46) 54 R32 10 20 10 12.7/ 6.4 19.4~46
1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 2100 3.05 9.6 ATQ60QRV16 White 310x1100x258 13 (18) 20.4 (17.0) 47/41/35 RQA60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12.7/ 6.4 19.4~46
FTYN
Series Heat pump
FOR ALL SEASONS
Saranet filter - Clean air supply
Ton: 1, 1.5, 1.8
Model Name Capacity
Programme dry function Reduces humidity
Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate (T/H/M/L/Q)
Self diagnosis - Digital display for easy maintenance
Fan Speed Sound Levels (T/H/M/L/Q) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels Dimensions (HxWxD) Machine Weight Operation range
Hot start - Prevents cold draughts
Max. Piping Length Max. Height Difference
Indoor Unit Outdoor Unit
FTYN35JXV1 RYN35CJXV1
FTYN50JXV1 RYN50CJXV1
FTYN60JXV1 RYN60CJXV1
5.25 5.28 1 phase, 220-240V, 50Hz 7.19 6.53 1,635 1,490
6.01 6.15
Cooling Heating
Kw Kw
3.15 3.38
Cooling Heating Cooling Heating Cooling Heating
A A W W W/W W/W
5.10 4.70 1,094 988 2.88 3.42 FTYN35JXV1
Cooling
m³/min cfm
10.5 / 10.1 / 8.4 / 6.9 / 6.4 372 / 355 / 298 / 242 / 225
dB (A) mm kg
41 / 40 / 35 / 29 / 28 288 x 800 x 206
Cooling
9 RYN35CJXV1
Type Cooling Cooling Heating
dBA mm kg °CDB °CWB m
IDU Colour: White
49 540 x 700 x 250 31
12 5
8.26 7.99 1,870 1,800
3.21 3.54 3.42 FTYN50JXV1 FTYN60JXV1 White 16.1 / 15.2 / 13.5 / 12.0 / 10.6 18.2 / 17.4 / 15.2 / 13.4 / 11.8 570 / 536 / 478 / 424 / 375 641 / 614 / 537 / 474 / 418 3 steps, Turbo and Quiet 44 / 42 / 39 / 36 / 34 48 / 46 / 43 / 40 / 37 310 x 1065 x 224 14 RYN50CJXV1 Light Grey Rotary 52 651 x 855 x 328 47 19°C to 46°C -9°C to 18°C
RYN60CJXV1 52 753 x 855 x 328 50
20 15
Measurement conditions: 1. Cooling: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, 24° CWB 2. Heating: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB 3. All units are being tested and comply to ISO 5151 (Non-ducted unit).
For the complete feature list please refer pages 30-31.
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 26/27
Unit options Indoor units No. 1 2
Item FTXR28KVMA FTXR42KVMA FTXR50KVMA 5-room centralised controller*1 KRC72A Wiring adaptor for time clock/remote controller*2 KRP413AB1S (Normal open pulse contact/normal open contact) 3 Air purifying filter set*3 KAF974B42S 4 Air supply filter with frame KAF963A43 5 Remote controller loss prevention chain KKF936A4 Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. Wiring adaptor supplied by DAIKIN. Time clock and other devices should be obtained locally. *3. A set of a frameless titanium apatite photocatalytic air-purifying filter and a frameless deodorising filter for the streamer discharge unit. Both filters are standard accessories.
5-room centralised controller KRC72A
Air purifying filter set
Air purifying filter set
KAF974B42S
KAF974B42S
Outdoor units No. Item 1 Air direction adjustment grille 2 Drain plug*1 3 Humidity hose extension joint*2 4 Humidity hose L cuff*2 5 Humidity hose (10 m) 6 Humidity hose extension set*3 Notes: *1. One set includes 5 pieces for 5 units. *2. One set includes 10 pieces. *3. One set includes a 2 m extension hose, 1 joint, and 2 tieraps
RXR28KVMA
RXR42KVMA KPW937AA4 KKP937A4 KPMJ942A4 KPMH950A4L KPMH942A42 KPMH942A402
RXR50KVMA
Drain plug
Humidity hose L cuff
KKP937A4
KPMH950A4L
Central remote controller
Unified on/off controller
DCS302CA51
DCS301BA51
Humidity hose extension set
System configurations No. Item FTXR28KVMA 1 Central remote controller* 2 Unified on/off controller* 3 Schedule timer* 4 Interface adaptor for D -NET use Note: *A wiring adaptor (KRP928BB2S) is also required for each indoor unit.
FTXR42KVMA DCS302CA51 DCS301BA51 DST301BA51 KRP928BB2S
FTXR50KVMA
Schedule timer DST301BA51
FTXG series No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 (1) (2) (3) (4)
Item Wired remote control (3) Cord for wired remote control 3m BRCW901A08 8m Wiring adapter normal open contact / normal open pulse contact Centralised control board Up to 5 rooms Anti-theft protection for remote control Central remote controller Unified on/off control Schedule timer Interface adapter for DIII-net Online controller External mounting kit for online controller Wifi power cable for online controller Touch LCD wall controller (4) Simple wall controller (4) KNX gateway Wiring adapter supplied by Daikin. Time clock and other devices: to be purchased locally. Writing adapter is also required for each indoor unit Cord for wired remote control BRCW901A03 or BRCW901A08 required. Can only be used in combination with online controller KKRP01A
FTXG25J
FTXG35J BRC944 BRCW901A03 KRP413A1S (1) KRC72 (2) KKF910A4 DCS302C51 DCS301B51 DST301B51 KRP928A2S KKR901A KKRPMO1A KKRPW01A KBRC01A KBRC501A KLIC-DD
FTXG50J
Indoor units No. Item Indoor units Indoor unitscentralised controller 1 5-room No. Item 2 No. 1 1 2 3 2 4 3 3 4 Note: 4 Note: Note:
FTXS25/35
Wiring for time clock/remote controller (normal open pluse contact/normal Item 5-roomadaptor centralised controller open 5-room centralised controller Wiringcontact) adaptor for time clock/remote controller (normal open pluse contact/normal Titanium apatitefor photocatalytic air purifying filter(normal open pluse contact/normal Wiring adaptor time clock/remote controller open contact) Remote controller loss prevention chain and open contact) Titanium apatite photocatalytic airfor purifying filterholder Titanium apatite photocatalytic airfor filterholder controller loss prevention chain and *1.Remote A wiring adaptor (KRP413AB1S) ispurifying also required for each indoor unit. Remote controller lossother prevention chainbe and holder locally. *2. time clock and devicesfor obtained *1. The A wiring adaptor (KRP413AB1S) isshould also required for each indoor unit. *3. filter is a standard accessory. It also should replaced approximately *1. The A wiring (KRP413AB1S) required for each indoor unit. every 3 years. *2. The time adaptor clock and other devicesisshould bebe obtained locally. *2. The The filter time clock and other devices should bebe obtained *3. is a standard accessory. It should replacedlocally. approximately every 3 years. *3. The filter is a standard accessory. It should be replaced approximately every 3 years.
Outdoor units No. Item units Outdoor Outdoor unitsadjustment grille 1 Air direction No. Item 2 No. 1 1 2 2
Drain plug adjustment grille Item Air direction Air direction Drain plug adjustment grille Drain plug
Control System No. ItemSystem Control Control System 1 Central remote controller No. Item
2 Unified No. Item 1 Central on/off remotecontroller controller 3 Schedule timercontroller 1 Central on/off remote controller 2 Unified 4 Interface adaptor for DIII-NET use 2 Unified on/off 3 Schedule timercontroller 3 Schedule timer 4 DIII-NET use is also required for each indoor unit. Notes: *1.Interface A wiringadaptor adaptorfor (KRP928BB2S) 4 Interface adaptor for DIII-NET use Notes: *1. A wiring adaptor (KRP928BB2S) is also required for each indoor unit. Notes: *1. A wiring adaptor (KRP928BB2S) is also required for each indoor unit.
*1 *1 *1 *1 *1 *1 *1
FTXS50/60/71 KRC72 FTXS50/60/71 FTXS25/35 FTXS25/35 KRP413AB1S KRC72 FTXS50/60/71 KRC72 KRP413AB1S KAF970A46 KRP413AB1S KAF952B42 KAF970A46 KKF917A4 KAF952B42 KAF970A46 KKF917A4 KAF952B42 KKF917A4
RXS25/35 KPW945A4 RXS25/35 KKP937A4 RXS25/35 KPW945A4 KPW945A4 KKP937A4 KKP937A4
RXS50/60/71 KPW945A4 RXS50/60/71 KKP937A4 RXS50/60/71 KPW945A4 (For RXS71KPW945A4 KKP937A4 KKP945A4) KKP937A4 (For RXS71(For RXS71KKP945A4) KKP945A4)
FTXS25/35E
FTXS50/60/71F
FTXS25/35E DCS302CA61 FTXS50/60/71F DCS301BA61FTXS50/60/71F FTXS25/35E DCS302CA61 DST301BA61 DCS302CA61 DCS301BA61 KRP928BB2S DCS301BA61 DST301BA61 DST301BA61 KRP928BB2S KRP928BB2S
Optional Wi-Fi adaptor kit code for KM, KP, FTKH Series-BRP072A42
Optional Parts
Indoor unit Indoor unit Indoor unit
Indoor unit Indoor unit Indoor unit
Optional Parts Optional Parts Titanium apatite photo catalytic air purifying filter Ag-ion (withphoto frame)catalytic air purifying filter Titaniumfilter apatite Multi-function filter Titaniumfilter apatite photo Ag-ion (with frame)catalytic air purifying filter Ag-ion filter (with Multi-function filterframe) Multi-function filter Optional Parts Optional Parts Titanium Optionalapatite Parts photo catalytic air purifying filter Ag-ion (withphoto frame)catalytic air purifying filter Titaniumfilter apatite Multi-function filter Titaniumfilter apatite photo Ag-ion (with frame)catalytic air purifying filter Ag-ion filter (with Multi-function filterframe) Multi-function filter
5 Star FTF35QRV16 FTF50QRV16 5 Star RF35QRV16 RF50QRV16 5 Star FTF35QRV16 FTF50QRV16 DTF35QRV16 DTF50QRV16 FTF35QRV16 FTF50QRV16 RF35QRV16 RF50QRV16 RFD35QRV16 RFD50QRV16 RF35QRV16 RF50QRV16 DTF35QRV16 DTF50QRV16 Included with the unit DTF50QRV16 in accessories bag DTF35QRV16 RFD35QRV16 RFD50QRV16 RFD35QRV16 Included with the unit RFD50QRV16 in accessories bag Included with the unit in accessories bag 5 Star ATF35QRV16 ATF50QRV16 5 Star RFA35QRV16 RFA50QRV16 5 Star ATF35QRV16 ATF50QRV16 ATF35QRV16 ATF50QRV16 RFA35QRV16 RFA50QRV16 Included with the unit in accessories RFA35QRV16 RFA50QRV16 bag Included with the unit in KAF001A500 accessories bag Included with the unit in KAF001A500 accessories bag KAF001A500
FTF60QRV16 RF60QRV16 FTF60QRV16 DTF60QRV16 FTF60QRV16 RF60QRV16 RFD60QRV16 RF60QRV16 DTF60QRV16 DTF60QRV16 RFD60QRV16 RFD60QRV16
FTC25QRV16 RC25QRV16 FTC25QRV16 DTC25QRV16 FTC25QRV16 RC25QRV16 RCD25QRV16 RC25QRV16 DTC25QRV16 DTC25QRV16 RCD25QRV16 RCD25QRV16
ATF60QRV16 RFA60QRV16 ATF60QRV16 ATF60QRV16 RFA60QRV16 RFA60QRV16
ATC25QRV16 RCA25QRV16 ATC25QRV16 ATC25QRV16 RCA25QRV16 RCA25QRV16
Remote Controller Loss Prevention with Remote Controller the Chain Remote Controller Loss Prevention with Loss Prevention with the Chain KKF917A4 the Chain KKF917A4 KKF917A4
5-room Centralised Controller 5-room Centralised 5-room Centralised Controller KRC72 Controller KRC72 KRC72
Titanium Apatite Photocatalytic Air-Purifying FilterPhotocatalytic Titanium Apatite Titanium Apatite Air-Purifying FilterPhotocatalytic KAF970A46 Air-Purifying Filter KAF970A46 KAF970A46 Titanium Apatite Photocatalytic AirPurifying Filter Titanium Apatite Photocatalytic AirTitanium Apatite Photocatalytic AirPurifying Filter KAF952B42 Purifying Filter KAF952B42 KAF952B42
Air Direction Adjustment Grille
Drain Plug
Air Direction Adjustment Grille KPW945A4 Air Direction Adjustment Grille KPW945A4 KPW945A4
Drain Plug KKP937A4 Drain Plug KKP937A4 KKP937A4
Central Remote Controller
Unified On/Off Controller
Schedule Timer
Central Remote Controller DCS302CA61 Central Remote Controller DCS302CA61 DCS302CA61
Unified On/Off Controller DCS301BA61 Unified On/Off Controller DCS301BA61 DCS301BA61
Schedule Timer DST301BA61 Schedule Timer DST301BA61 DST301BA61
3 Star FTC35QRV16 3 Star FTC50QRV16 FTC60QRV16 FTQ35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 3 Star FTC35QRV16 FTC50QRV16 FTC60QRV16 FTQ35QRV16 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 FTC35QRV16 FTC50QRV16 FTC60QRV16 FTQ35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 RCD35QRV16 RCD50QRV16 RCD60QRV16 RQD35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 KAF970A45 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 RCD35QRV16 RCD50QRV16 RCD60QRV16 RQD35QRV16 RCD35QRV16KAF057A41 RCD50QRV16 RCD60QRV16 RQD35QRV16 KAF970A45 KAF001A500 KAF970A45 KAF057A41 KAF057A41 KAF001A500 KAF001A500 3 Star ATC35QRV16 3 Star ATC50QRV16 ATC60QRV16 ATQ35QRV16 RCA35QRV16 3 Star RCA50QRV16 RCA60QRV16 RQA35QRV16 ATC35QRV16 ATC50QRV16 ATC60QRV16 ATQ35QRV16 ATC35QRV16 ATC50QRV16 ATC60QRV16 ATQ35QRV16 RCA35QRV16KAF970A45 RCA50QRV16 RCA60QRV16 RQA35QRV16 KAF057A41 RCA35QRV16KAF970A45 RCA50QRV16 RCA60QRV16 RQA35QRV16 Included with the unit in accessories bag KAF970A45 KAF057A41 KAF057A41 Included with the unit in accessories bag Included with the unit in accessories bag
2 Star FTQ50QRV16 2 Star RQ50QRV16 2 Star FTQ50QRV16 DTQ50QRV16 FTQ50QRV16 RQ50QRV16 RQD50QRV16 RQ50QRV16 DTQ50QRV16 DTQ50QRV16 RQD50QRV16 RQD50QRV16
FTQ60QRV16 RQ60QRV16 FTQ60QRV16 DTQ60QRV16 FTQ60QRV16 RQ60QRV16 RQD60QRV16 RQ60QRV16 DTQ60QRV16 DTQ60QRV16 RQD60QRV16 RQD60QRV16
2 Star ATQ50QRV16 2 Star RQA50QRV16 2 Star ATQ50QRV16 ATQ50QRV16 RQA50QRV16 RQA50QRV16
ATQ60QRV16 RQA60QRV16 ATQ60QRV16 ATQ60QRV16 RQA60QRV16 RQA60QRV16
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29 DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29 DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29
Feature list Technology Humidity control Comfortable airflow
Comfort control
Lifestyle convenience
Cleanliness
Timers
Worry free
Control
Function Swing compressor and reluctance DC Motor Rotary compressor PAM control Humidifying operation Drying operation Dry cooling operation Moisturising operation Cooling breeze operation Comfortable mode Power-airflow flap Power-airflow dual flaps Wide-angle louvres Vertical auto swing Horizontal auto swing 3-D airflow Comfort sleep operation Hot start Coanda airflow Indoor unit quiet operation Outdoor unit quiet operation Intelligent eye Automatic operation (Heating & Cooling) Programme dry function Auto fan speed Temperature and humidity level information display Econo mode Home leave operation Inverter powerful operation New powerful operation (non-inverter) Power chill operation Indoor unit on/off switch Child lock Multi-colored indicator Monitor brightness setting Fan only Filter cleaning indicator (on R/C) Mould shock operation Home leave ventilation Streamer discharge air purifier Mould-proof operation Mould proof stick Smell proof operation Titanium apatite photocatalytic air purifying filter Air purifying filter Air intake filter Silver particle anti-bacterial filter Saranet filter Air purifying filter with photocatalytic deodersing function Fresh air supply ventilation Multi-function filter Wipe-clean flat panel 24-Hour on/off timer Count up-down on/off timer Weekly timer Night set mode Good sleep off timer New good sleep off timer Auto restart (after power failure) Stabiliser free operation Self-diagnosis PE anti-corrosion treatment of outdoor heat exchanger Remote control with backlight Luminescent remote control buttons Indoor temperature display on remote control Remote control LCD back light off Smartphone connection
FTXR 28/42/50 FTXG 25/35/50 FTXS 25/35 FTXS 50/60/71 FTKM 25/35 FTKM 50/60/71 DTKM 25/35 DTKM 50/60 ATKM 25/35 ATKM 50/60 FTKP 25/35 FTKP 50/60/71 DTKP 25/35 DTKP 50/60/71 ATKP 25/35 o o o o o o o o o o o o o o o o o o o o o
o
o
o
o o
o o o
o o o o o
o
o
o
o o o o o o
o o o o o o
o o o o o o
o
o
o
o
o
o
o
o
o
o
o
o o o o o o o o o o o o
o o o o o o
o o
o o o o o o o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o o o
o o
o o o o
o o
o o o o
o o
o o o o
o o
o o o o
o o
o o o o
o o o o
o o o
o o o
o o o o
o o o o
o o o
o o o
o o
o o
o o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o
o
o o o
o o o
o o o
o o o
o o o
o o o
o o o
o o o
o o o
o o o
o o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o
o o
o o
o Option
o Option
o o
o o
o o
o o
o Option
Option
Option
Option
Option
o
o
Option
Option
Option
Option
o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o o o o o
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o Option
o o o o o o o o
o o
o o
o o
o o
o
o
o
o
o
o
o o o o o
o o o o o
o o
o o
Technology Humidity control Comfortable airflow
Comfort control
Lifestyle convenience
Cleanliness
Timers
Worry free
Control
Function ATKP 50/60/71 o Swing compressor and reluctance DC Motor Rotary compressor PAM control o Humidifying operation Drying operation Dry cooling operation Moisturising operation Cooling breeze operation Comfortable mode Power-airflow flap o Power-airflow dual flaps Wide-angle louvres o Vertical auto swing o Horizontal auto swing o 3-D airflow o Comfort sleep operation Hot start Coanda airflow o o Indoor unit quiet operation o Outdoor unit quiet operation Intelligent eye Automatic operation (Heating & Cooling) Programme dry function o Auto fan speed o Temperature and humidity level information display Econo mode o Home leave operation Inverter powerful operation New powerful operation (non-inverter) Power chill operation o Indoor unit on/off switch o Child lock o Multi-colored indicator Monitor brightness setting Fan only o Filter cleaning indicator (on R/C) Mould shock operation Home leave ventilation Streamer discharge air purifier Mould-proof operation Mould proof stick Smell proof operation o Titanium apatite photocatalytic air purifying filter Option Air purifying filter Air intake filter Silver particle anti-bacterial filter o Saranet filter Air purifying filter with photocatalytic deodersing function Fresh air supply ventilation Multi-function filter Wipe-clean flat panel o 24-Hour on/off timer o Count up-down on/off timer Weekly timer Night set mode Good sleep off timer New good sleep off timer o Auto restart (after power failure) o Stabiliser free operation o Self-diagnosis o PE anti-corrosion treatment of outdoor heat exchanger o o Remote control with backlight Luminescent remote control buttons Indoor temperature display on remote control o Remote control LCD back light off o Smartphone connection Option
FTKH 35 FTKH 50/60 FTF35 FTF50/60 DTF35 DTF50/60 ATF35 ATF50/60 FTC 25/35 FTC50/60 DTC 25/35 DTC50/60 ATC 25/35 ATC50/60 FTQ35 FTQ50/60 DTQ35 DTQ50/60 ATQ35 ATQ50/60 FTYN o o o o o o o o o o o o o o o o o o o o o o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o Option o
o Option o
o o
o o
o o
o o
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
o Option
Option
Option
Option
Option
Option
Option
o
o
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
o
o
Option o o
Option o o
Option o o
Option o o
Option o o
Option o o
Option o
Option o
Option o
Option o
o o
o o
Option o
Option o
Option o
Option o
o o
o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o o o o
o o o o
o o o o o
o o o o o
o o o o o
o o o o o
o o o o o
o o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o o o o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o o
o o
o o
o o
o o
o o
o
o
o o
o o o o
Option
Option
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 30/31
o o
Ten Reasons to Buy Daikin Air-conditioning specialist
Pioneer in air-conditioners
The Daikin edge with in-house manufacturing
High energy efficiency
Comprehensive range and quiet operation
Daikin focuses on air-conditioning solutions and control systems. As specialists, it’s all we do. No wonder Daikin is recognised as an expert in air-conditioning.
Daikin has been providing air-conditioning solutions for over 15 years in India. As one of the industry’s more trusted names, Daikin air-conditioning equipment can be found in homes, offices, hotels and shops. Daikin is committed to the air-conditioning market and has a manufacturing facility located in Rajasthan.
Daikin is the only company in the world dedicated to manufacturing both air-conditioning systems and refrigerants. Each element has been designed to work flawlessly with the next - delivering optimal performance - from the time a project begins till the moment of absolute comfort.
Daikin’s continuous drive for improved efficiency has seen its advanced inverter technology being applied to split, ducted and other systems. These systems provide a more comfortable environment and are more energy efficient when compared to noninverter systems.
Daikin has a comprehensive range of products in both domestic and commercial segments. Designed to provide effective and quiet air-conditioning, Daikin can customise a solution to meet every requirement.
Unmatched after-sales support
Five-year warranty on compressors
Wise investment – Low running cost
Experienced dealers
Environment friendly
Daikin takes pride in providing its customers with efficient after sales support, including readily available spare parts warehoused in India.
Reliability. That’s probably top of your list when buying an airconditioning system for your home or business. Daikin gives you peace of mind and reassurance with their five-year warranty on compressors of split airconditioners. That’s how confident Daikin is about the quality and reliability of its product.
When you buy a Daikin airconditioning system you need to look beyond the initial purchase price. It pays to consider ongoing running costs in conjunction with the potential life of the product. Daikin systems offer superior build quality and energy efficiency.
Daikin distributes its products through experienced dealers. This ensures that you receive a top quality product with expert support. Together this means the best air-conditioning solution for your individual needs.
Daikin continues to work towards a sustainable future, and has received Environmental Management System certification to ISO14001. Daikin Airconditioning India Pvt. Ltd. is dedicated to preserving and protecting the environment through the production of energy efficient products.
Terms & Conditions Apply
Contact Address DAIKIN AIRCONDITIONING INDIA PVT. LTD. 12th Floor, Building No 9 Tower A, DLF Cyber City DLF Phase III, Gurgaon 122002 Haryana, India Tel: 0124-4555444, Fax: 0124-4555333 Email ID:
[email protected] Sales & Service Offices
Tel: 080-25590452-54 Chandigarh Tel: 0172-5089862-64 Chennai Tel: 044-24314210-15
Hyderabad Tel: 040-39134289
Mumbai Tel: 022-30926666
Jaipur Tel: 0141-2223215
Pune Tel: 020-25560300
Kolkata Tel: 033-22894259/60
(
[email protected])
Bengaluru
Lucknow Tel: 0522-2787307/340
Service toll free 1800-102-9300, 1800-22-9300
[email protected] Visit us at www.daikinindia.com /daikinindia
/daikinindia
daikinindiablog.com
/company/daikin-airconditioning-india-pvt.-ltd.
Disclaimer As a continuing policy of product innovation of Daikin, the design and specifications are subject to change without prior notice. The visuals of the products in the brochure are representative only, actual products might differ from the ones shown. Sales revenue includes revenue through sales of all Daikin Airconditioning Systems. World’s no. 1 position based on internal assessment of total sales revenue for 2012-13. ‘Products mentioned in this brochure comply with RoHS regulations as per E-waste (Management & Handling) Rules, 2011and should not be mixed with general household waste at the end of their useful life.’ For more details kindly visit our website www.daikinindia.com or contact our customer care centre at 1800 102 9300 / 1800 22 9300
concept and design at
Tel: 079-26583013-14
Delhi NCR Tel: 0124-4555444
DAIPL-2014/14-RA20-1A
Ahmedabad