Nitrox Network. High Standard. Best Quality. High Standard. Best Quality. Made in Germany. Professional

Nitrox Network Egypt Nitrox Network Maldives School Street Beside Elektric Company Hurghada Red Sea | Egypt H. Esjehivilla 4th floor Medhuziyaraiy ...
Author: Morgan Wright
19 downloads 0 Views 7MB Size
Nitrox Network Egypt

Nitrox Network Maldives

School Street Beside Elektric Company Hurghada Red Sea | Egypt

H. Esjehivilla 4th floor Medhuziyaraiy Magu Male‘ | Rep. of Maldives

[email protected] [email protected]

[email protected] [email protected]

Phone 0020(0)653451270 Mobile 0020(0)191177993

Phone 009607684306

NRC International GmbH

ProNRC

Kölner Straße 159 51645 Gummersbach Tel.: 02261/500414

Sudetenstr. 21 64572 Büttelborn Tel.: 02261-500 416

[email protected] www.nrc-international.com Fax: 02261/500415

Nitrox Network

[email protected] www.pronrc.com Fax: 02261-42617

High Standard Best Quality

High Standard

High Standard Best Quality

Best Quality q

Made in Germany Professional

ProNRC Crossover If you are already a Nitrox instructor from another organisation, then you just need to fill in an application form to become a ProNRC Nitrox instructor. You just need to mail us the form together with a photo and a copy of your previous Nitrox instructor card and within a few days we will give you an instructor number and access to the member area on our website. For your 79,- Euro annual fee you will get 2 complete Kits free of charge and a DVD with all the presentations, exams and answer keys on it. We also have free Pro NRC Nitrox flags for the dive centers.

31

Inhalt NRC Products NRC Membrane Systems Air Pro Series Light Series

4 4 6

NRC Compressors Compressor AP 100 Compressor AP 170 to AP 320 Compressor AP 170S to AP 320S Compressor AP 400S to AP 625S

8 8 10 12 14

NRC Nitrox System

16

NRC Analyser Pick O2 Analyser O2 Professional Analyser Helium Analyser

18 18 20 21

NRC Oxygen Sensors

22

NRC Accessories

24

ProNRC Products Nitrox Training Material

26

Submatix Training Material

28

ProNRC Accessories

30

1

NRC Air Pro Series

The completely revised Air Pro Series now sets new standards in Nitrox production. It is a completely integrated system which will withstand even the most hardest conditions.

Extended operational time power reduced industrial compressor technology very high quality in construction, components and production High performance with low power input energy saving regulation compressor element and electric drive with high efficiency compact construction

4

The control and monitoring systems of the Air Pro Series are simplified even further than existing NRC gas management range. All necessary information like pressure, oil temperature and service intervals is presented on a clear and easy to read LCD display on the front panel.

High air quality

The assembly effort decreases to a minimum, because the system is delivered ready for use and tested.

High reliability

special designed oxygen module

no wear in the oxygen modules

filter unity free of oil, refrigerant dryer and industrial filter

an industrial rotary screw compressor reduced in its revolution speed

Compact and rugged construction complete integrated system rugged powder-coated 2 millimetre steel case (also as stainless steel available)

industrial construction Low maintenance costs long service intervals few wearing parts extra long lifetime of all components

In the NRC Air Pro system, a power reduced rotary screw compressor performes its work. Maximum durability and operation period is guaranteed by the power reduction of this special system. The access to the low pressure compressor, refrigerant dryer and filter system has been optimized, so service and maintenance allows the technician uncomplicated and unimpeded access to the whole system.

A special “Tropical Kit” (optional) ensures a high standard of performance even at very high ambient air temperature and humidity. The dry and clean air from the low pressure compressor passes a triple filter array then passes, as oil free and high purity breathing air, into a hollow fibre membrane. The membrane body is a specially designed oxygen module, which

distinguishes itself by its excellent air quality and air supply performance. The performance of the fibre membrane is limited by a safety valve to ensure a long constant economic lifetime. The Air Pro Series has a performance of 300 to 1000 l/min Nitrox with up to 40 % oxygen, therefore, it is the optimum system for middle and large Dive Centers.

Performance

Air Pro 5,5

Air Pro 7,5

Air Pro 11

Air Pro 15

Delivery rate 32% Nitrox

300 l/min

350 l/min

500 l/min

600 l/min

Delivery rate 36% Nitrox

-

350 l/min

500 l/min

600 l/min

Delivery rate 40 % Nitrox

-

-

300 l/min

450 l/min

Membrane body

1 x oxygen module 1.0

1 x oxygen module 1.0

1 x oxygen module 2.0

1x oxygen module 2.0

Maximum pressure

13 bar

13 bar

13 bar

13 bar

Filter

3 stage

3 stage

3 stage

3 stage

Compresssor

AP 5

AP 7,5

AP 11

AP 15

Working pressure

7-10 bar

7-10 bar

7-10 bar

7-10 bar

Compresssor pressure

10 bar

10 bar

10 bar

10 bar

Compresssor principle

screw

screw

screw

screw

Weight (incl. extensions)

180 kg

230 kg

235 kg

400 kg

Measures (L x W x H)

490 x 470 x 680

670 x 850 x 840

670 x 850 x 840

820 x 900 x 1470

Dryer

separat

separat

separat

separat

Dew Point

< 6°C

< 6°C

< 6°C

< 6°C

Weight

43 kg

43 kg

43 kg

52 kg

Measures (L x W x H)

526 x 336 x 525

526 x 336 x 525

526 x 336 x 525

763 x 483 x 510

Special equipment construction is possible, for example diesel-operated or for safari boats.

5

NRC Light Series

With the NRC PG Light Series you can produce Nitrox blends with oxygen contents ranging from 28 % to 40 %. With this system you do not need a separate compressor; the plant is simply connected to a high pressure bank, which makes it more than ever suitable for application in areas with limited electrical power supply. The necessary space for putting in place is extremely reduced and permits thus installations on smallest areas. The plants are simple to handle, extremely uncomplicated to maintain and reliable in service.

Parts Package: The NRC PG Light membrane unit consists of the following parts: Input pressure reducer 200 bar, triple oilfree filters (with extra cartridges), oxygen membrane, and needle valve, high and low pressure relief valve, oxygen analyzer and backup memory for the original Nitrox blend. Function: As soon as the air of the high pressure bank flows through the membrane,

Advantages

6

you can read off the actual oxygen content of the gas mixture on the digital analyzer. The compressed air is separated inside the membrane into its components oxygen and nitrogen. By adjusting the needle valve, you can produce different mixtures between 28 % - 40 % oxygen. The redundant nitrogen is led over a valve out of the membrane. The produced Nitrox leaves the membrane with ambient pressure and is directed into the buffer memory.

Reduced need of space

Nitrox blends ranging from 28 % to 40 % oxygen

Can operate in high ambient temperatures

No oxygen needed

Easy handling

No separate compressor needed

Extremely easy servicing

No additional power consugmption

Failure safe

A high pressure compressor compresses the Nitrox and fills it up into the diving tanks. If a change of mixing proportion is needed, simply adjust the needle valve to the desired blend. By means of a lever valve it can be specified whether the high pressure com-pressor is supplied with ambient air or with the produced Nitrox. There is no wear of the oxygen membrane during use, which guarantees an extremely high life span. With the NRC PG Light Series, service is reduced

to a minimum and is basically limited to the replacement of the filter cartridges. The NRC PG Light Series can be upgraded at any time to the Professional Series, by retrofitting a low pressure compressor.

Pressure reducer 300 bar Professional Analyser

Options: Membrane Casing Compressed air reservoir

Picture shows optional compressed air reservoir Picture shows optional membrane casing

Performance

PG 400 Light

PG 600 Light

Performance 32 % O2 L/min* Performance 36 % O2 L/min* Performance 40 % O2 L/min*

400 l/min 400 l/min 450 l/min

600 l/min 600 l/min 650 l/min

Dimensions BxHxL in mm

150 x 1050 x 600

150 x 1050 x 600

Weight in kg

30

40

7

NRC Compressor AP 100

Breathing Air Compressor 100 l/min Max. Press.

Capacity

Type

bar

L/min

Cfm

KW

PS

AP 100 -E-225*

225

100

3,5

2,2

AP 100 -B-225

225

100

3,5

AP 100 -E-310*

310

100

3,5

AP 100 -B-310

310

100

3,5

* Special voltages/frequences

8

Drive Power

2,2

RPM

Stages

Filter

Filling Hoses

3

1200

3

P2

1

5,5

1200

3

P2

1

3

1200

3

P2

1

5,5

1200

3

P2

1

Standard Features: P21 Purifier w Refillable Purifier Cartridge 2nd and 3rd Stage Water Seperators Intercoolers (Stainless Steel) After Cooler (Stainless Steel) Priority Valve 1 Filling Hose (Yoke, Filling Valve, Pressure Gauge, DIN Adapter) Portable Manual Drain Air Quality comply with EN 12021

Prime mover

Dimensions

Weight

WxLxH

Kg

Electromotor 400 V / 3-Phasen / 50 Hz

89 x 40 x 48

58

Electromotor 230 V / 1-Phase / 50 Hz od. 60 Hz

89 x 40 x 48

58

Gasoline Honda

92 x 37 x 46

63

Optional Equipment: Automatic Start/Stop Auto Drain Diesel Engine Extra Filling Hose

9

NRC Compressor AP 170 to AP 320

Breathing Air Compressor 170 L/min to 320 L/min

10

Max. Press.

Capacity

Drive Power

RPM

Stages Filter

Filling Hoses

Type

bar

L/min

Cfm

KW

PS

AP 170-E-225

225

170

6

4

5,5

1300

3

P2

2

AP 170-B-225

225

170

6

6

1300

3

P2

2

AP 170-E-310

310

170

6

5,5

1300

3

P2

2

AP 170-B-310

310

170

6

6

1300

3

P2

2

AP 240-E-225

225

240

8,4

7,5

1500

3

P4

2

AP 240-B-225

225

240

8,4

AP 240-E-310

310

240

8,4

9

1500

3

P4

2

7,5

1500

3

P4

2

AP 240-B-310

310

240

8,4

9

1500

3

P4

2

AP 320-E-225

225

320

11

7,5

10

1700

3

P4

2

AP 320-E-310

310

320

11

7,5

10

1700

3

P4

2

4 5,5 5,5

Standard Features: P21 with refillable Purifer Element for FAD upto 170lt/min P41 Purifier(Stainless Steel) w Refillable Purifier Cartridge (Stainless Steel) for FAD higher than 170lt/min 2nd and 3rd Stage Water Seperators Intercoolers (Stainless Steel) After Cooler (Stainless Steel) Priority Valve Check Valve 2 Filling Hoses (Yokes, Filling Valves, Pressure Gauges DIN Adapters) Manual Drain Air Quality comply with EN 12021

Type

Prime Mover

Dimensions

Weight

WxLxH

Kg

AP 170-E

Electromotor 400V / 3-Phasen/50 Hz

125 x 54 x 70

133

AP 240-E

Electromotor 400V / 3-Phasen/50 Hz

125 x 54 x 70

133

AP 320-E

Electromotor 400V / 3-Phasen/50 Hz

125 x 54 x 70

133

AP 170-B

Gasoline Honda

125 x 54 x 70

137

AP 240-B

Gasoline Honda

125 x 54 x 70

137

Optional Equipment: Automatic Start/Stop Auto Drain Extra Filling Hose Dual Pressure System (225/310 Bar)

11

NRC Compressor AP 170S to AP 320S

Breathing Air Compressor 170 L/min to 320 L/min „ Silent“

12

Max. Press.

Capacity

Drive Power

RPM

Stages

Filter

Filling Hoses

Type

bar

L/min

Cfm

KW

PS

AP 170S-E-225

225

170

6

4

5,5

1300

3

P2

2

AP 170S-E-310

310

170

6

4

5,5

1300

3

P2

2

AP 240S-E-225

225

240

8,4

5,5

7,5

1500

3

P4

2

AP 240S-E-310

310

240

8,4

5,5

7,5

1500

3

P4

2

AP 320S-E-225

225

320

11

7,5

10

1700

3

P4

2

AP 320S-E-310

310

320

11

7,5

10

1700

3

P4

2

Standard Features: P41 Purifier(Stainless Steel) w Refillable Purifier Cartridge (Stainless Steel) 2nd and 3rd Stage Water Seperators Intercoolers (Stainless Steel) After Cooler (Stainless Steel) Priority Valve Check Valve Interlocked Filling Panel w2 Filling Hoses (Yokes, Filling Valves, DIN Adapters) Isolated Sound-Proof Canopy AutoDrain Automatic Start/Stop Oil Pressure Switch Control Panel: 3 Stage Pressure Gauges, Pressure Switchgaugean Oil Pressure Gauge Electric Panel: Y starter, Main Switch, On/Off Buttons, Hourmeter, Emergency Pushbuttons Air Quality comply with EN 12021

Type

Prime Mover

Dimensions

Weight

WxLxH

Kg

AP 170S-E

Electromotor 400V / 3-Phasen / 50 Hz

70 x 88 x 121

295

AP 240S-E

Electromotor 400V / 3-Phasen / 50 Hz

70 x 88 x 121

300

AP 320S-E

Electromotor 400V / 3-Phasen / 50 Hz

70 x 88 x 121

310

Optional Equipment: Extra Filling Hose Dual Pressure System (225/310 Bar) Electronic Control System

11 13

NRC Compressor AP 400S to AP 625S

Breathing Air Compressor 400 L/min to 625 L/min „ Silent“

14

Max. Press.

Capacity

Drive Power

RPM

Stages

Filter

Filling Hoses

Type

bar

L/min

Cfm

KW

PS

AP 400S-E-225

225

400

14

7,5

AP 400S-E-310

310

400

14

7,5

10

630

4

P61

4

10

630

4

P61

4

AP 560S-E-225

225

560

20

11

15

890

4

P61

4

AP 560S-E-310

310

560

20

11

15

890

4

P61

4

AP 625S-E-225

225

625

22

15

20

1000

4

P61

4

AP 625S-E-310

310

625

22

15

20

1000

4

P61

4

Standard Features: P61 Purifier(Stainless Steel) w Refillable Purifier Cartridge (Stainless Steel) High Pressure Particle and Oil Removal Filter (Srainless Steel) 2nd and 3rd Stage Water Seperators (Stainless Steel) Intercoolers (Stainless Steel) After Cooler (Stainless Steel) Priority Valve Check Valve Removable Filling Panel with 4 Filling Hoses (Yokes, Filling Valves) and Cylinder Pressure Gauge Canopy Isolated from Subbase for Smoothest Operation Auto drain Automatic Start/Stop Oil Level Switch Control Panel: 4 Stage Pressure Gauges, Main Switch, On/Off Buttons, Hourmeter, Test, Reset and Emergency Pushbuttons Electric Panel: Y starter Tropical Cooling with Double Fans Forced Ventilation Air Quality comply with EN 12021

Type

Prime Mover

Dimensions

Weight

WxLxH

Kg

AP 400S-E

Electromotor 400V / 3-Phasen / 50 Hz

77 x 132 x 161

667

AP 560S-E

Electromotor 400V / 3-Phasen / 50 Hz

77 x 132 x 161

694

AP 625S-E

Electromotor 400V / 3-Phasen / 50 Hz

77 x 132 x 161

715

Optional Equipment: Extra Filling Hose Dual Pressure System (225/310 Bar) Electronic Control System

15

NRC Nitrox System

Function

Low Pressure Supply

A complete NRC Nitrox System consists of a low pressure air supply with integrated air purification and also a Nitrox Membrane Unit with control units and regulation hardware.

The low pressure air supply, which, depending on the type of system you choose, consists of a low pressure compressor or an array of high pressure storage banks, this in turn supplies virtually oil-free air to the Nitrox Membrane Unit, with a pressure between 7-10 bar.

The heart of the Nitrox Unit is an oxygen membrane of the latest and most advanced design. This membrane is characterized by excellent performance which produces only the highest gas quality. The oxygen enriched air is produced by separating nitrogen and oxygen and enrichment can be obtained up to a maximum of 40 % oxygen (depending on the type of system) by the simple to use „Turnkey“ operation of an integrated needle valve. The accuracy is to 0.1 % of the displayed value.

Nitrox produced this way can then be supplied to a high pressure compressor, which compresses and the gas then fills it into diving tanks. Obviously the high pressure compressor can still be used to compress normal breathing air and can be switched over to Nitrox tanks by way of a directional control valve.

16

The low pressure compressors used in the NRC Nitrox System is one Air Pro Series. At NRC we consider that the supply of high quality, clea oil free air is paramount.

Air conditioning

In the refrigeration compressed air dryer warm moisture sturatet c air is cooled down to +3°C. The internal separator system separate densed water drops from the compressed air stream. Filter: Compressed Air is a valuable source of power. It is safe, flexibl in all areas of industry. Like any other energy source it benefits f clean and free from impurities.

Nitrox Membran The heart of each NRC Nitrox System is the Nitrox Membrane, an oxygen membrane of the latest and most advanced design. Depending on the type of system, different oxygen membranes can be utilized. All membrane types are characterized by extremely high air quality and supply performance. A special filter unit installed before the oxygen membrane guarantees virtually oil-free air and contributes thus to practically an unlimited life span. The Nitrox production of the various membrane units ranges from 200 to over 1500 liter/minute.

one of the NRC , clean, dry and

High Pressure Compressor

tet compressed arates the con-

exible and used fits form being

Virtually every existing high pressure compressor can be utilized in tandem with an NRC Nitrox Membrane System. Obviously the same compressor can still be used for compressing normal breathing air thanks to a change over switch, thus no additional high pressure compressor is needed for producing Nitrox.

17

NRC Pick O2 Analyser

With our oxygen analyser we can provide a handy measuring instrument with any advantages and precise measuring technology. In spite of the low overall size and an easy use this handy oxygen analyser has an an excellent oxygen sensor with an measuring exactness. The NRC oxygen analyser is equipped with an electro-chemical sensor and micro controller to measure oxygen concentrations of 0-99%. Designed

18

as an single-serving analyser with a life span of at least two years, it is a perfect oxygen analyser for daily use at Dive Centers. The usual exchange of the oxygen sensor is no longer necessary. Moreover, the price of an oxygen sensor with an average life span of one year is equale to the price of a new analyser with an operation period of approxiamately two years. Owing to the compact construction dimensions and the low weight the

NRC oxygen analyser is a perfect travel companion for ambitious scuba divers, who set value on quick and precise oxygen analysis. The analyser is constantly ready to function and indicates the value on a two-digit display.

Technical details NRC oxygen analyser accessories The NRC oxygen analyser is available with different extraction sets and can,

therefore, be connected to every Nitrox valve. An optional available BCD extraction set also allows a comfortable analysis via the inflator tube.

Oxygen analyser with BCD extraction set.

Oxygen analyser with tube extraction set.

NRC oxygen analyser specification The information refers to the following surrounding conditions: 1013 hPa, 25 degrees Celsius and dry ambient air.

Measuring principle: Display: Calibration: Resolution: Sample rate: Connector: Response Time: Accuracy: Temperature range: Storage area: Operation period: Weight: Dimensions:

Galvaic-oxygen-sensor 12,7 mm 1 Button, after pressing displayed value = 21 Vol.% O2 1 Vol.% O2 1 per second M 16 x 1 less than 2 second +/- 0,5 Vol. % O2 from 0 to 50% O2 0 - 50 degree Celsius perfect 5 to 25 degree Celsius, max. -5 to 60 degree Celsius approxiamately 2 years 80 g 74mmx48mmx59mm (HxWxD)

NRC oxygen calibration Calibration can easily be reached by pressing the button on the top of the case until „CA“ will appear in the display. The analyser adapts itself automatically to 21 Vol.% O2.

19

NRC O2 Professional Analyser

Professional Oxygen Analyser in an robust plastic case. All data’s are referring to 25°C, 50% relative humi dity and 1013hPa. The sensor D-13 is the exchange-sensor for this analyser.

Device Type: Sensor: Measurement Range: Accuracy: Display: Data Memory: Operating temperature: Batteries: Capacity of Battery: Power supply: Weight: Size:

20

SM 2000 D, P/N 45 00 29 SM 2000 I, P/N 45 00 28 Electro-chemical Oxygen Sensor 0 to 99,9 Vol. % O2 0,5 Vol. % ± 2% LCD Dot Matrix 128x64 Up to 50 000 data points 0 to 40°C Lithium Polymer 3,7V / 1,1Ah, rechargeable > 40h, if full loaded, no backlight on 5Volt , 700mA DC 300 gram incl. Sensor + Cable (SM 2000 D) 265 gram (SM 2000 I) 200 x 70 x 30 mm

NRC Helium Analyser

The Helium Analyser is a hand-held device for measuring helium content in a gas mixture, and is specifically designed to confirm the Helium content in a gas mixture similar to normal air or nitrogen. The Analyser is powered by rechargeable batteries. The LCD displays the helium content from 0 to 100 % with 0.1 % resolution. When the low battery indicator LED is on, the unit‘s battery needs to ne recharged prior to use. The patented sample unit allows the user to flow a gas mixture through the sensor inside the unit, as well as to seal the gas mixture in the sensor for measurement.

21

NRC Oxygen Sensors

High-quality oxygen sensors manufactured in Germany The number of oxygen analyser used in scuba diving has strongly risen during the last years. In many cases analyser used in scuba diving, were not developed for this particular purpose, but rather for the application in the industrial or medical field. Although these analyser work uncomplainingly in scuba diving, the first

22

problems appear, if the oxygen sensor has to be exchanged. Due to the bad availability and a high price the exchange of an oxygen sensor will be often uneconomical or even impossible. NRC offers for nearly all oxygen analyser located at the market exchange sensors, which distinguish itself by a high-class quality. The production in Germany guarantees a top quality and thus exact measuring results. As the

production of the sensors occur only with order, no storage times originate, what effects extreme positively on the life span of the oxygen sensor. Delivery can be made within 7 days. Every sensor will be tested individually and a test protocol will be issued, what can be seen any time if requested. All sensors will be delivered in an airtight box, what also allows a storage.

Measuring Instr. & Rebreather

NRC

Teledyne

Analytical Industries, Inc.

Dive Rite VTI Oxygen measuring Instr., MSA Mini-OX, Vandergraph VN202, Spectrum, CIS-Lunar

D-01 Unit No.: 223-0001

R-17MED R-17D

PSR-11-39-JD

Draeger Oxy-Gauge single cathode, Ohmeda Oxygen Analyzer

D-02 Unit No.: 223-0002

R-15

PSR-11-15-D

Analox OMS, UBS O2 Stick

D-03 Unit No.: 223-0003

R33D

PSR-11-37-D7

Uwatec Oxy2

D-04 Unit No.: 223-0004

R-22-D

PSR-11-39-MD2

Buddy Inspiration, Uwatec Oxy2, VR3, Oxy Spy, KISS, CCR-2000, Cochran Lifeguard, SUBMATIX Oxyscan 100 PRO, Megalodon

D-05 Unit No.: 223-0005

R-22D

PSR-11-39-MD

Draeger Oxy Gauge dual cathode, Draeger Oxydig

D-06 Unit No.: 223-0006

R-23

PSR-11-15-2D

Teledyne TED60

D-07 Unit No.: 223-0007

T-7

PSR-11-77D

Analox‘s Mini O2, Mini O2 D II, UBS, OBS

D-08 Unit No.: 223-0008

O-92

PSR-11-37-D03

Analox, OMS, UBS

D-09 Unit No.: 223-0009

R33D-1

PSR-11-37-D2

MK-16, Commercial Biomarine MK15/15-5, CCR-1000 rebreathers (Magnetic) (2), SM 1600

D-10 Unit No.: 223-0010

High Output Model #2 R10DS

PSR-11-33-NM1

Andi Alpha 1, SM 1600, CCR-1000

D-12 Unit No.: 223-0012

R22DHO

PSR-11-39-MD1

NRC Professional Oxygen Analyser

D-13 Unit No.: 223-0013

(the exchange-sensor for our NRC O2 Professional Analyser up to 2009 (green))

Submatix

N0R3 Unit No.: 223-0014

NRC Professional Oxygen Analyser

M-49 Unit No.: 223-0049

(the exchange-sensor for our NRC O2 Professional Analyser from 2010 (white))

D-01/Unit No.: 223-0001

D-02/Unit No.: 223-0002

D-03/Unit No.: 223-0003

D-04/Unit No.: 223-0004

D-05/Unit No.: 223-0005

D-06/Unit No.: 223-0006

D-07/Unit No.: 223-0007

D-08/Unit No.: 223-0008

D-09/Unit No.: 223-0009

D-10/Unit No.: 223-0010

D-12/Unit No.: 223-0012

D-13/Unit No.: 223-0013

D-13/Unit No.: 223-0014

D-13/Unit No.: 223-0049

23

NRC Accessories

The Nitrox neoprene tank covers for the identification of Nitrox tanks. The cover is simply pulled over the tank, with or without net. Complex handling with Nitrox stickers is not longer necessary. You can now change the outside identification on Nitrox or air tanks any time and very fast. Very durable finishing, available in two sizes, for 10l tanks or for 12l/15l tanks.

Nitrox tank tags are made from rewritable plastic. The following data can be registered on the tag: Date, O2 %, MOD (max. operation depth) and diver’s name. The tag has the size of a credit card and can be fastened to the tank neck.

24

25

ProNRC Nitrox Training Material

ProNRC is not to be considered simply a classical training organization, but rather a developer of modern and innovative training programs. Over the last 40 years the picture of recreational divers has been defined by diving with compressed air in combination with the so-called „open system“. Although it is technically as well as medically far outdated, still the majority of recreational divers use this combination. „Modern diving gases and diving devices“ offer big advantages concerning safety, comfort and performance to every diver and furthermore fun and pleasure.

Thus today there are hardly any diving centers/schools which do not offer Nitrox diving and/or Nitrox training to their guests. It won‘t be long and Nitrox will surely replace the normal compressed air a fact four years ago nobody really believed in. A large part of this development surely happened thanks to simplified training methods in addition to professional training materials. This is the chief strength of ProNRC: to create training materials which convey knowledge in a simple and comprehensible way.

Since long alternative breathing gases are not any more considered „exotic“ diving variants - a fact shown by their strong presence all over the world.

ProNRC Nitrox Workbook is our teaching book for Nitrox Diving. One of the goals of ProNRC is to create training materials with the newest educational insights to allow you to learn and teach as easily as possible. The knowledge we impart is at highest level! We are thankfull that we can offer our training material in several languages, because we had great help from well-known personages of the diving-scene. It is available in German, English, French, Italian, Spanish, Russian and Dutch.

ProNRC Nitrox Dive Table The ProNRC Nitrox Dive Table suitable to the ProNRC Nitrox Workbook.

26

ProNRC User PIC

ProNRC User Brevet

for the Nitrox User Certification.

comes in combination with the User PIC and is handed to the User. It is also available for Nitrox Instructors.

ProNRC Nitrox KIT includes the Nitrox Workbook, the Nitrox Dive Table and the User PIC

27

ProNRC Submatix Training Material

ProNRC Submatix CCR Workbook

ProNRC Submatix SCR Workbook

is our teaching material used for the Submatix CCR.

is our teaching material used for the Submatix SCR.

ProNRC Submatix CCR Dive Table

ProNRC Submatix SCR Dive Table

The Dive Table suitable to the ProNRC Submatix

The Dive Table suitable to the ProNRC Submatix

CCR Workbook

CCR Workbook

ProNRC Submatix KIT The Workbooks also come as a KITs including the Workbook, the Dive Table and the PIC.

28

ProNRC Discover Rebreather Diving

Workbook Dolphin & Dräger Ray

is used for the Submatix and the Dräger Dolphin discover course.

is used for the Dräger Ray and the Dräger Dolphin course.

ProNRC User Brevet and PIC combination Brevet with User PIC used for the User Certification. It is also available for Rebreather Instructors.

29

ProNRC Accessories

Tank Sticker

Sticker

Banner

Banner 30

Logo Sticker

Poster

Poster

Poster

ProNRC Crossover If you are already a Nitrox instructor from another organisation, then you just need to fill in an application form to become a ProNRC Nitrox instructor. You just need to mail us the form together with a photo and a copy of your previous Nitrox instructor card and within a few days we will give you an instructor number and access to the member area on our website. For your 79,- Euro annual fee you will get 2 complete Kits free of charge and a DVD with all the presentations, exams and answer keys on it. We also have free Pro NRC Nitrox flags for the dive centers.

31

Nitrox Network Egypt

Nitrox Network Maldives

School Street Beside Elektric Company Hurghada Red Sea | Egypt

H. Esjehivilla 4th floor Medhuziyaraiy Magu Male‘ | Rep. of Maldives

[email protected] [email protected]

[email protected] [email protected]

Phone 0020(0)653451270 Mobile 0020(0)191177993

Phone 009607684306

NRC International GmbH

ProNRC

Kölner Straße 159 51645 Gummersbach Tel.: 02261/500414

Sudetenstr. 21 64572 Büttelborn Tel.: 02261-500 416

[email protected] www.nrc-international.com Fax: 02261/500415

Nitrox Network

[email protected] www.pronrc.com Fax: 02261-42617

High Standard Best Quality

High Standard

High Standard Best Quality

Best Quality q

Made in Germany Professional