E Project: MorphoAccess Enrollment Management System (MEMS)

MorphoAccess Enrollment Station Installation Guide

Document N°: M417-051B Version: 10.0 Date: 19 May 2005

Produced by e Siège social : 27, rue Leblanc 75512 Paris Cedex 12 − France Service Client : SAGEM SA SAV Terminaux Biométriques Boulevard Lénine − BP428 76805 Saint Etienne du Rouvray − FRANCE Tel +33 2 35 65 55 05 Hotline : E-mail : [email protected] Tel +33 1 34 64 55 14 Copyright © 2005 E www.sagem.com SAGEM document - Reproduction and disclosure prohibited

S

MorphoAccess Enrollment Station Installation Guide

s Table of Contents

Table of Contents 1.

2.

3.

Hardware Description............................................................................... 1-1 1.1.

Enrollment Station ......................................................................... 1-1

1.2.

MorphoAccess Terminal................................................................ 1-2

System Assembly ..................................................................................... 2-1 2.1.

MorphoAccess Cabling.................................................................. 2-3

2.2.

PC Cabling ...................................................................................... 2-3

2.3.

SCM Encoder Cabling .................................................................... 2-3

2.4.

MSO Cabling ................................................................................... 2-4

System Configuration............................................................................... 3-1 3.1.

3.2. 4.

MorphoAccess Configuration ....................................................... 3-1 3.1.1.

Network Configuration ......................................................... 3-1

3.1.2.

Connected Mode Configuration ........................................... 3-1

3.1.3.

Relay Configuration ............................................................. 3-1

3.1.4.

Language Configuration ...................................................... 3-1

3.1.5.

Output Configuration............................................................ 3-1

3.1.6.

Welcome Message Configuration ........................................ 3-2

PC Configuration............................................................................ 3-2

Installation of the Enrollment Station Application ................................. 4-1 4.1.

Your PC is Already Fitted with a MEMS........................................ 4-1

4.2.

New Version Installation ................................................................ 4-2 4.2.1.

Microsoft® Access 2000 Database Installation.................... 4-4

4.2.2.

Microsoft® SQL Database Installation ................................. 4-4

4.2.3.

Oracle Database Installation................................................ 4-7

4.3.

Acrobat Reader Installation........................................................... 4-9

4.4.

Registered Licences ...................................................................... 4-9

4.5.

Software Protection ..................................................................... 4-11

4.6.

Station Update .............................................................................. 4-11

4.7.

Station Deletion ............................................................................ 4-12

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

TC-1

MorphoAccess Enrollment Station Installation Guide

s Table of Contents

5.

MSO Installation........................................................................................ 5-1

6.

MorphoPAK Installation ........................................................................... 6-1

7.

Service Safe Installation........................................................................... 7-1

8.

MEMS Application Start-up ...................................................................... 8-2

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

TC-2

MorphoAccess Enrollment Station Installation Guide

s List of Figures

List of Figures

Figure 1-1: Optical MorphoSmart..................................................................................1-2 Figure 1-2: SCM card encoder.......................................................................................1-2 Figure 1-3: MorphoAccess description. .......................................................................1-3 Figure 2-1: Architecture contains a standalone system using a MorphoTouch for fingerprint acquisition .............................................................................................2-1 Figure 2-2: Architecture containing a standalone system using a MSO to capture fingerprints ...............................................................................................................2-2 Figure 2-3: Integration into an access control system ...............................................2-2 Figure 2-4: PC cabling diagram.....................................................................................2-3 Figure 4-1: Custom Setup options ................................................................................4-2 Figure 4-2: Unselect an option ......................................................................................4-3 Figure 4-3: Select the database to be installed............................................................4-3 Figure 4-4: Select the MEMS SQL server (Client Version)..........................................4-5 Figure 4-5: Select the MEMS SQL server (Full Version) .............................................4-6 Figure 4-6: Select the SQL Reporting server (Full Version) .......................................4-6 Figure 4-7: Select the Oracle Server (Client version)..................................................4-7 Figure 4-8: Select the Oracle MAES Server..................................................................4-8 Figure 4-9: Select the Oracle REPORT Server .............................................................4-8 Figure 4-10: Acrobat Reader installation......................................................................4-9 Figure 4-11: Licence Manager application main screen ...........................................4-10 Figure 4-12: List of the registered licences and their status....................................4-10 Figure 4-13: Update menu............................................................................................4-11 Figure 4-14: Select an option.......................................................................................4-12

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

LF-1

s

MorphoAccess Enrollment Station Installation Guide

Revision History

Revision History

Version

Date

Edition or modification

1.0

10/08/01

Creation of Document

2.0

28/11/01

Document update

3.0

03/07/02

Document update following software changes

4.0

28/08/02

Document update

5.0

03/10/02

Document update

6.0

16/01/03

Document update

6.1

09/04/03

Document update

6.2

10/06/03

Document update

7.0

21/01/04

Document update in accordance with MEMS (aka MAES) release 5.0

7.1

09/03/04

Additional Microsoft® SQL Server installation procedure

7.2

29/03/04

New separated MSO installation procedure Additional "MEMS Application Start-up" paragraph

8.0

22/10/04

Document update in accordance with MEMS release 5.1

9.0

24/02/05

Document update: add SCM card encoder

10.0

12/05/2005

Document update in accordance with MEMS release 5.2

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

Rev-1

s

MorphoAccess Enrollment Station Installation Guide

1 - Hardware Description

1. HARDWARE DESCRIPTION

SAGEM access control system is made up of one or more MorphoAccess terminals, a PC fitted with the ES application and an MSO.

1.1. Enrollment Station The PC fitted with the ES application is called enrollment station. It is used to record personal access control information. During this phase, called enrollment phase, the alphanumeric data (first name, last name, etc.) and the biometric data (fingerprints) are recorded. Once recorded, this information is sent to the MorphoAccess terminal, which will use them to grant or deny access. The Enrollment Station PC must meet the following requirements: − Minimum requirements: A Pentium III 750MHz processor; 512 Megabytes of RAM; a network card; a parallel port; a serial port; 4 USB ports. − Its display resolution should be of 1024 X 768 at least. − Operating system specification: Windows 2000 Server™ Service Pack 2, Windows 2000™ Service Pack 2, Or Windows XP™ ServicePack1. The application uses either an ACCESS 2000™ or an SQL Server™ database, or an ORACLE™ database. For fingerprint capture, you need an Optical MorphoSmart 100 to capture fingerprints, instead of a MorphoTouch. The Optical MorphoSmart 100 is a SAGEM fingerprint sensor which is plugged in a USB port. It only runs under Windows 2000™ or Windows XP™.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

1-1

MorphoAccess Enrollment Station Installation Guide

s 1 - Hardware Description

Figure 1-1: Optical MorphoSmart The enrollment PC can be fitted with an SCM card encoder. This encoder is used for customers who want to issue contactless badges to their users. This option is necessary if the system contains MorphoAccess MA220 (or MA320) terminals.

Figure 1-2: SCM card encoder

1.2. MorphoAccess Terminal The MorphoAccess is installed at the access point you want to secure. It is generally hung on the wall. Like the MorphoTouch, it is made up of a screen, a keyboard and a fingerprint sensor.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

1-2

MorphoAccess Enrollment Station Installation Guide

s 1 - Hardware Description

Figure 1-3: MorphoAccess description. The MorphoAccess can control an electrical lock or communicate with an access controller. There are 3 types of MorphoAccess terminals: − MA200: it stores 1 internal database of 800 records; − MA300: it stores 16 databases of 3,000 records each. Before placing their finger on the fingerprint sensor, users will have to enter their database number (unless it is 0, which is the by-default database); − MA220: Any person wanting to be authentified by the MorphoAccess must have a contactless access card. He/She passes his/her card in front of the MorphoAccess to proceed to the authentication. The MA220 can also operate as a MA200. − MA221: MA220 with false finger detection integrated feature. − MA221d: MA221 with encrypted data management (DESFire) and false finger detection.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

1-3

s

MorphoAccess Enrollment Station Installation Guide

2 - System Assembly

2. SYSTEM ASSEMBLY

The system is made up of a MorphoAccess and an enrollment PC. All of these elements should be supplied and connected on the same network. For safety reasons, it is recommended to use a dedicated network, separated from the company’s one. The system can work alone.

Switch Relay, Other

Ethernet Connection Ethernet Connection USB link

Ethernet Connection

12V Serial link 12V

Power supply

Power supply

Power supply

Figure 2-1: Architecture contains a standalone system using a MorphoTouch for fingerprint acquisition

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

2-1

s

MorphoAccess Enrollment Station Installation Guide

2 - System Assembly

The system can contain a MSO to capture fingerprints. Switch Relay, Other

Ethernet Connection

USB link

Ethernet Connection

USB Connection

12V

Main power supply Power supply

Power supply

Figure 2-2: Architecture containing a standalone system using a MSO to capture fingerprints It can also be configured to work with an access control system. In this case, it is necessary to connect the MorphoAccess to the controller. Controller server

Controller

Controller

Controller

Serial link Wiegand Data Clock Or TCP/IP

Switch

Ethernet Connection

12V

12V Main power supply Power supply

Power supply

Power supply

Power supply

Figure 2-3: Integration into an access control system

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

2-2

s

MorphoAccess Enrollment Station Installation Guide

2 - System Assembly

2.1. MorphoAccess Cabling The MorphoAccess must be connected to the various system elements: − power supply; − network; − electrical lock or access control system.. Follow the instructions in SAGEM SA MORPHOACCESS Installation guide document in order to link the various connectors to the network, relay and power supply.

2.2. PC Cabling To power supply

To switch

Figure 2-4: PC cabling diagram.

2.3. SCM Encoder Cabling This section only concerns customers who provide contactless cards to their users. Connect the reader/encoder USB plug to the PC USB port (or via a USB hub). The windows wizard to add device is automatically launched. For an installation under windows 2000 or XP, browse to the file S331DI2K.sys in the folder SCM_SCR331DI\Win2K-XP at the root of the MEMS installation CD-ROM. For windows 9x or Me, you need the file SCM_SCR331DI\Win9x-Me\ S331DI9X.sys.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

2-3

MorphoAccess Enrollment Station Installation Guide

s 2 - System Assembly

2.4. MSO Cabling This section only concerns customers who use an MSO to capture fingerprints. The MSO is connected to the PC USB port (or via a USB hub). But the connection must be performed after the application installation, including the copy of this device's drivers.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

2-4

s

MorphoAccess Enrollment Station Installation Guide

3 - System Configuration

3. SYSTEM CONFIGURATION

3.1. MorphoAccess Configuration

3.1.1.

Network Configuration

At the MorphoAccess level, to access the administration menu, refer to SAGEM SA MORPHOACCESS Installation guide and follow the instructions. This guide explains how to configure the IP address, the sub-network mask and the gateway by default. In case of any problem, please contact your system administrator.

3.1.2.

Connected Mode Configuration

Configure the "stand - alone" mode to allocate itself the value " 0 ". Refer to SAGEM SA MORPHOACCESS Installation guide for detailed information.

3.1.3.

Relay Configuration

Configure the relay according to your needs (time of opening), and indicate in the "active" menu the value corresponding to your cabling. Check the SAGEM SA MORPHOACCESS Installation guide for detailed information.

3.1.4.

Language Configuration

You can also select the MorphoAccess language (French, English and Spanish). Refer to SAGEM SA MORPHOACCESS Installation guide for detailed information.

3.1.5.

Output Configuration

If you use MorphoAccess terminals with an access control system, you must configure the terminals to send the person's identifier to the controller. According to the controller specification, you can use serial link, Wiegand, Data Clock or TCP/IP. The configuration is described in SAGEM SA MORPHOACCESS Installation guide.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

3-1

MorphoAccess Enrollment Station Installation Guide

s 3 - System Configuration

3.1.6.

Welcome Message Configuration

When a MorphoAccess terminal recognizes someone, a welcome message is displayed. You can add to this message the identifier of the person (by default), his/her last name or his/her first name. Refer to SAGEM SA MORPHOACCESS Installation guide for more details.

3.2. PC Configuration The MorphoTouch, PC and terminals must be configured to work on the same network (contact your system administrator for further information). The physical system is now configured. You can verify that each stage is correctly done, by sending a "ping" command from a DOS window. Each terminal must answer (MorphoAccess terminals and MorphoTouch if you are fitted with).

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

3-2

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4. INSTALLATION OF THE ENROLLMENT STATION APPLICATION

When the physical installation of the system is completed, proceed to the application installation.

4.1. Your PC is Already Fitted with a MEMS In this case, firstly you have to uninstall the previous version. Step 1: Save the previous database called 'server.mdb' located in the application directory (by default: \Program Files\Sagem\MAES\ or \Program Files\Sagem\ES\). Copy it in a temporary directory or in a floppy disk. Or perform a backup of the SQL Server. Step 2: Uninstall the previous version: From Start\Parameters\Control Panel, click on "Add/Remove programs", select 'MorphoAccessES' (or 'ES' if you use a 3.1 version or older), or MEMS 5.x; Click "Remove". NOTE:

Microsoft® SQL Server functionalities enable to perform backups. Please refer to the Microsoft® documentation for the detail and configuration of the backup procedure.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-1

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.2. New Version Installation Insert the "MorphoAccess enrollment station" CD and launch the "Setup.exe" application. On the first screen, enter your identity, then click "Next" to obtain the following screen:

Figure 4-1: Custom Setup options From this screen, you can select or unselect options: − Sagem MEMS: it is required and corresponds to the minimal installation; − Matching subsystem: it is necessary if you possess the enrollment station with duplicate search; − Card Encoder subsystem: this option is required if you want to issue contactless badges for your users. It concerns customers fitted with MA220 (or MA320) terminals.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-2

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

Figure 4-2: Unselect an option When you have unselected the options you do not want, click the “Next” button, then ”Install”. During the installation process, the following is displayed. It proposes a choice between three types of database:

Figure 4-3: Select the database to be installed Choose the required database type:

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-3

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

− MEMS Standard connected to Microsoft Access database format: install a local Microsoft® Access 2000 database; − MEMS Server connected to SQL server database: install the software package on an SQL Client workstation except for Group Management, MALoadMonitor and Reporting Tool that will be installed on the server station; − MEMS Client connected to SQL server database: install the whole set of software in SQL configuration. − MEMS Server connected to Oracle server database: install the software package on an Oracle Client workstation except for Group Management, MALoadMonitor and Reporting Tool that will be installed on the server station; − MEMS Client connected to Oracle server database: install the whole set of software in Oracle configuration.

4.2.1.

Microsoft® Access 2000 Database Installation

Select Access 2000 and follow the instructions of the installation wizard.

4.2.2.

Microsoft® SQL Database Installation

MEMS Server version installation with Microsoft® SQL Server requires a specific procedure. Following is the required procedure: 1.

Install Microsoft® SQL Server on a PC with Microsoft® Windows 2000™ Server

2.

Install MEMS Server. At the end of the installation, the SQL server you have installed can be selected (See SQL Client Version Installation page 4-5 or SQL Full Version Installation page 4-6).

3.

Restore the MEMS database. They correspond to the maes.bak (general database) and maesreport.bak (reporting database) files. These files are stored in the SQL Server sub-directory of the MEMS installation directory. The MEMS database must be restored using the functionalities available in Microsoft® SQL Server. Please refer to the following paragraph for the database restore procedure.

4.

Control the database connection security. It is advised to: a) Create "maes" user for the connection to the "maes" database with the “maes” password. b) Create "maesreport" user for the connection to the "maesreport" database with the “maes” password.

Database Restore Procedure: 1.

In the "Tools" menu, click on "Restore"

2.

In the "Restore DataBase " dialog box, enter maes, check "From device" and click on "Select device..."

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-4

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

3.

In the "Choose Restore Device" dialog box, check "Disk", click on "Add..." and select the maes.bak file.

4.

Click OK to validate.

5.

Follow the same procedure for the database associated with the maesreport.bak file.

NOTE:

4.2.2.1.

For the Microsoft® SQL Server configuration, SAGEM advises to perform regular backups. Microsoft® SQL Server functionalities enable to perform these backups. Please refer to the Microsoft® documentation for the detail and configuration of the backup procedure.

SQL Client Version Installation

If you choose to install a Client Version SQL database, during the installation process the following screen will be displayed. It allows to select the MEMS SQL server on which the SQL database will be installed.

NOTE: The list of available SQL servers will be displayed here. This list may vary according to the SQL servers available on your network.

Figure 4-4: Select the MEMS SQL server (Client Version) NOTE:

The software installation will be partial on the Client workstation. The remaining applications will be installed on the server. The MEMS launcher will only display the following applications: Configuration, Enrollment Station, Card layout and Users Management.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-5

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.2.2.2.

SQL Full Version Installation

If you choose to install a Full Version SQL database, during the installation process the following screens will be displayed. They allow to select the MEMS SQL server and the one on which the Reporting database will be installed.

NOTE: The list of available SQL servers will be displayed here. This list may vary according to the SQL servers available on your network.

Figure 4-5: Select the MEMS SQL server (Full Version)

NOTE: The list of available SQL servers will be displayed here. This list may vary according to the SQL servers available on your network.

Figure 4-6: Select the SQL Reporting server (Full Version) Note also that the ODBC sources will be activated for connection to MEMS.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-6

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.2.3.

Oracle Database Installation

MEMS Server installation with ORACLE requires a specific procedure. The recommended procedure is as follows: 1.

Install Oracle 9i on a PC with Microsoft® Windows 2000™ or 2003™ Server operating system.

2.

Create two Oracle database: MAES and MREPORT, with user login: maes and password: maes. Add the DBA access rights to this user.

3.

Install MEMS Server. At the end of the installation procedure, the network name of the machine hosting the Oracle server will be asked (Refer to Oracle Client Installation on page 4-7 or Oracle Server Installation on page 4-8).

4.

Start an Oracle client (for instance SQL Plus Worksheet)

5.

Connect to the database (user login: maes, password: maes, Service: maes).

6.

If a previous version of MEMS has already been installed, clean the MAES and MREPORT databases. Open and execute, from the Oracle client, the drop_maes.sql and drop_maes_report.sql files located in the Oracle subdirectory of the installation directory.

7.

For all other cases, open and execute maes_schema_oracle.sql to create the MAES table, then maesreport_oracle.sql to create the MREPORT table.

8.

Execute insert_maes_oracle.sql to complete the MAES database, then insert_mreport_oracle.sql to complete the MREPORT database.

4.2.3.1.

Oracle Client Installation

If you choose to install a Client version Oracle database, during the installation process the following screen will be displayed. It allows to select the Oracle server on which the Oracle database will be installed.

Figure 4-7: Select the Oracle Server (Client version)

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-7

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.2.3.2.

Oracle Server Installation

If you choose to install a Server version Oracle database, during the installation process the following screens will be displayed. They allow to select the Oracle server and the one on which the Reporting database will be installed.

Figure 4-8: Select the Oracle MAES Server

Figure 4-9: Select the Oracle REPORT Server

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-8

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.3. Acrobat Reader Installation In the last part of the installation process, a dialog box appears to ask you if you wish to install Acrobat Reader. This editor is necessary to display product documentation. Click the “Yes” button if this software is not installed yet on your computer.

Figure 4-10: Acrobat Reader installation Acrobat Reader setup is automatically launched. Follow instruction for a standard application by clicking on the “Next” button when asked. Click “Finish” at the end of the process. After the installation, if you use an MSO, you can connect it to the PC USB port. You can also refer to the user documentation that provides the first steps with the station.

4.4. Registered Licences Before running the one of the MEMS applications, it is compulsory to have at hand the delivered "dongle" and the licence file containing the registered licence numbers. 1. Connect the dongle to the PC parallel port. NOTE: If you use a USB dongle, connect it to a free USB port. Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-9

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

2. Launch the Licence Manager application (Start\Programs\SAGEM MEMS 5.1\Licence Manager). The following window is displayed:

Figure 4-11: Licence Manager application main screen 3. Click the "Install Licence File" button. The "Open" window to find files is displayed. 4. Select the licence file provided by SAGEM and click OK. The modules with registered licences are displayed in the "Module" column and their "Status" is set as "VALID", as illustrated below:

Figure 4-12: List of the registered licences and their status 5. Close the Licence Manager window.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-10

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

4.5. Software Protection The different functionalities of MEMS are now protected by activation keys. For each “sensitive” function, an activation key is set depending on the dongle and the label of the function: − MACI for the communication with MA − MEMS_STD for MEMS with Access, − MEMS_SERV for MEMS Server with SQL Server, − MEMS_CLI for MEMS Client with SQL Server − WSQ for fingerprint images, − MORPHOPAK for portrait capture, − IMPR_PASS for the printing station. Installation with ORACLE will be protected by the same licenses as for the installation with SQL SERVER: − The ORACLE client should have MEMS_CLI license − The ORACLE server should have MEMS_SERV license.

4.6. Station Update If, later on, you want to add options to the station, re-insert the "MorphoAccess enrollment station" CD and launch the "setup.exe" application. The following menu is displayed:

Figure 4-13: Update menu Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-11

s

MorphoAccess Enrollment Station Installation Guide

4 - Installation of the Enrollment Station Application

Select the “Modify” option to bring back the screen of figure 4.2. Re-select the options you want by clicking the icon on the left of the option then by selecting the first line.

Figure 4-14: Select an option

4.7. Station Deletion Follow the instructions of paragraph 4.3 and select the “Remove” option in the screen of figure 4.3.Then, click on ”Next”. WARNING: For every update action, application repair and deletion, a database backup is achieved if you installed the standard MEMS version. This one is in the application current directory (by default \Program Files\sagem\MAES) with the name server_copy.mdb. To complete the uninstallation, delete this file manually. So, the data will be definitively lost. NOTE: The enrollment station can work with the MorphoKit dlls, from a MorphoKit V 3.1 and 3.2 if you use an MSO. If your PC is fitted with MorphoKit and MEMS, and you uninstall MEMS, it will be necessary to re-install the dongle drivers from the MorphoKit CD. For any further information about data update or deletion, refer to the documentation in the menu Start Programs SAGEM MEMS 5.1 Documentation. The system is now installed. Before making it operational, you must configure it (refer to the user guide).

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

4-12

MorphoAccess Enrollment Station Installation Guide

s 5 - MSO Installation

5. MSO INSTALLATION

The enrolment station software installation CD has a "MSO Driver" directory containing the MSO drivers installation program. Insert the "MorphoAccess enrollment station" CD and in the "MSO Driver" directory launch the "Usb Driver for MorphoSmart.exe" application. Follow the instructions of the installation wizard by clicking on the “Next” button when asked. Click “Finish” at the end of the process.. If a “Digital Signature Not Found” window is displayed, click on “Yes” and carry on the installation wizard.

Note: If a previous installation of the drivers exists on your machine, first you must uninstall the existing drivers with this installation program and relaunch the program to install the new drivers.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

5-1

s

MorphoAccess Enrollment Station Installation Guide

6 - MorphoPAK Installation

6. MORPHOPAK INSTALLATION

If you registered a licence for the MorphoPAK, the enrolment station software installation CD will have a "MorphoPAK" directory containing the different files necessary to its installation. Insert the "MorphoAccess enrollment station" CD and in the "MorphoPAK" directory launch the "Setup.exe" application. Follow the instructions of the installation wizard and refer to the MorphoPAK Installation Guide for more information about the hardware configuration. NOTE: The MorphoPAK Installation Guide.pdf file and the drivers of the different cameras are available at the root of the "MorphoPAK" directory.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

6-1

s

MorphoAccess Enrollment Station Installation Guide

7 - Service Safe Installation

7. SERVICE SAFE INSTALLATION

NOTE: This module is only installed when using DESFIre MorphoAccess (MA221d). On the MEMS CD-ROM, execute the "ServiceSafeSetup.exe" file.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

7-1

s

MorphoAccess Enrollment Station Installation Guide

8 - MEMS Application Start-up

8. MEMS APPLICATION START-UP

The first time the MEMS application is used, only one application will be available: Users Management, which allows to create and manage users' profiles (Administrators and Operators), as well as their access rights to the applications. If you click on another icon a message will inform you that you do not have access rights. IMPORTANT: The first user created in the system must have system administration access rights. This access right is called: "System Configuration". Create Administrator profile and MEMS Operators: 9.

Click the "Users Management" icon of the MEMS Launcher.

10. Enter the default confadmin password. This password is only asked at first use. When users are created, this application is only available for the users with "System Configuration" access rights. 11. Create a super user with system configuration access rights. Refer to the section 4.2. Users' Profiles Creation page 4-27 of the Enrollment Station User's Guide - M417-052B v8.0. 12. Create "Operator" users.

WARNING: The names of the different MEMS users created must correspond to Windows® logins. If you create a different user than ‘maes’, the system allows you to change default connection parameters to the database. Launch ‘Settings’ application, a window will be displayed. You will just need to fill the new user login, password, and DSN Name (‘maes’ by default). MEMS system is using ODBC components to connect to the database. You can configure yourself the data source name (DSN Name). Please refer to Microsoft windows documentation.

Doc. No. M417-051B - Version 10.0 - 19 May 2005 SAGEM Document - Reproduction and disclosure prohibited

8-2