MODEL CTU-200 CAL & UCU-200 CAL Use & Care

l Uso y Mantenimiento

MODEL UCU-200 CAL

Use & Care

MODEL CTU-200 CAL

Use & Care

Contents (EN).................................................................................3-34 Contenido (SP) ............................................................................35-66

CONTENTS Introduction ...........................................................................................................4 Russ Zylstra Chairman of the Board

Benjamin Zylstra Chief Executive Officer

Features ...................................................................................................................5 Safety Precautions .............................................................................................5

Congratulations on your purchase of the AquaNano! I know you will enjoy using it to provide economical, fresh tasting water directly from your kitchen faucet for yourself and your family. Our goal at Rena Ware is always to offer the best quality products backed by excellent customer service. That is why we are sure you can count on the quality of your AquaNano water filter now and in the future. You can also count on Rena Ware to be there for you if you have any questions about installing or using your AquaNano and for any of your future service needs. Please feel free to contact us if you have any questions about your AquaNano water filter or about any of our other fine Rena Ware products.

CTU 200......................................................................................................................6

Product Diagram ............................................................................................7 Installation/Operation .................................................................................8

UCU 200 ................................................................................................................. 13

Product Diagram .......................................................................................... 14 Installation/Operation .............................................................................. 16

Accessories............................................................................................................ 25 ¡Felicitaciones por su compra del AquaNano! Estoy seguro de que lo disfrutará para obtener agua fresca de agradable sabor a bajo costo directamente del grifo de su cocina para usted y su familia. Nuestra meta en Rena Ware es ofrecer productos de la más alta calidad respaldados por un excelente servicio al cliente. Por eso estamos seguros de que puede contar con la calidad de su filtro de agua AquaNano en el presente y en el futuro. También puede tener la seguridad de que Rena Ware lo ayudará con las preguntas que usted pueda tener sobre la instalación o el uso de su AquaNano y con los servicios que pueda requerir en el futuro. No dude en comunicarse con nosotros en caso de tener alguna pregunta sobre su filtro de agua AquaNano o cualquiera de los otros excelentes productos Rena Ware.

Care & Maintenance CTU 200 & UCU 200 .............................................. 26 Replacement Indicator Lights...................................................................... 26 Non-Functioning Flow Meter....................................................................... 27 Back-Flushing, cleaning & replacing the Pre-Filter EM Media & the NanoCeram® Cartridge ............................................................................................................... 28 Troubleshooting ............................................................................................... 32 Replacement Parts .......................................................................................... 33 Specifications ...................................................................................................... 33 Warranty Information ..................................................................................... 34

Benjamin Zylstra Chief Executive Officer / Jefe Ejecutivo

3

EN

Features

Introduction You now own one of the most advanced home water filtration systems available anywhere. The AquaNano utilizes electropositive technology as part of a multi-stage, high flow filtering system with limited pressure drop. This unique, multi-function system provides you and your family with economically filtered water straight from the tap:

• Stage 1: Pre-Filtration - The pre-filter removes larger suspended solids dramatically extending the life of your NanoCeram® cartridge.



The AquaNano features a convenient spray/stream wand so you can direct the flow of water where you want it. This makes it easier to fill bottles and containers and to rinse vegetables and fruits.



A visual flow meter indicates when it is time to replace the NanoCeram® Cartridge to ensure your supply of filtered water is uninterrupted.



The AquaNano will effectively filter water for up to one year or 3,000 gallons/11,355 liters whichever comes first.

Safety Precautions

• Stage 2: Electropositive Filtration - The second stage utilizes NanoCeram® patented electropositive filtration media with dirt holding capacity and filtration efficiency for particles as small as a nanometer or .001 micron.



• Stage 3: Advanced Carbon Block Technology - The third stage utilizes carbon block technology and special leadsorbent media to absorb and reduce chlorine, lead, tastes and odors.



The AquaNano’s NanoCeram® Cartridge has a rated capacity of 11,355 liters (3,000 gallons) or one year which ever occurs first. The NanoCeram® Cartridge must be replaced when the indicator light flashes red. The actual capacity will depend on the amount of suspended solids and particles in your local water system. In certain water supplies, tastes or odors may return or the flow may decrease prior to the rated capacity. In these cases the NanoCeram® Cartridge should be replaced more often.



It is essential that you follow the operation and maintenance instructions enclosed for proper performance. Failure to follow the Use and Care instructions will void the warranty.



Do not use with water below 4˚C (40˚F).

• ∆ WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection. Always replace the NanoCeram® filter cartridge when the indicator light turns red.

The AquaNano is equipped with an electronic flow meter to advise you when to reorder and to replace the NanoCeram® Cartridge.

NSF International System Tested and Certified by NSF International against NSF/ANSI Standards 42 & 53 for the reduction of chlorine, lead, and cysts.

This filter is engineered to filter municipally treated water in the home.

NOTE: Contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water. Proper maintenance in accordance with the Use and Care must be followed.

State of California Registration numbers:

14-3018, 14-3019

4

5

EN

Product Diagram





1. Cover 2. Reusable Pre-Filter Housing (includes one EM Media Insert)

3. NanoCeram® Filter Cartridge 4. Inlet Assembly (including hose) 5. Back Flush Adapter

1

(for use on the Pre-Filter Cartridge Only)

6. Diverter Valve 7. Diverter Valve Gasket 8. Base 9. Locking Plate 10. Wand 11. Battery Door (AA Batteries not included) 12. Two Disposable EM Inserts

5 4

12

10 3 11

7 6

Model CTU-200 CAL Installation/Operation 6

Figure 1 If any of these items are missing, please contact Rena Ware Customer Service 7

EN

Remove the AquaNano and cartridge(s) from their shipping boxes, remove packing materials, and compare box contents with the product diagram. (Figure 1.)

5. The length of the hose between the Inlet Assembly and the Diverter Valve Assembly may be adjusted if needed. You can feed the hose into the base from the diverter end and pull it out at the inlet end to make it longer.



Installation/Operation

1. Lift the cover from the base assembly. 2. Install two new AA, high quality batteries (not included) in the filter base.



3. Remove the NanoCeram® Cartridge and the Pre-Filter Cartridge from its plastic bags. 4. To install the NanoCeram® cartridge, place it into the locking plate on the base. Once inserted into the base, rotate the cartridge clockwise slightly to lock. Insert the Pre-Filter Cartridge into the locking plate at the top of the NanoCeram® Cartridge in the same way.



label

You can also feed the hose into the Base from the inlet end and pull it out the diverter end to make it shorter. Be sure not to pull the hose too tightly over the filter cartridge as this may restrict flow.







6. The Inlet Assembly attaches to the top of the Pre-Filter Cartridge. It is inserted the same way the cartridges connect. Rotate the Inlet Assembly approximately 1/8 turn clockwise so that the hose at the Wand side of the filter lines up with the Wand stem.



label

8

9

EN 9. Place the AquaNano on a flat counter surface near the sink. With the Wand pointing outward over the sink, turn on the water and divert it through the filter by turning the lever on the Diverter Valve 90°. Check for leaks.



7. Using padded or locking pliers, remove the existing aerator from your faucet.

8. Remove the protective wrap from the Diverter Valve assembly. NOTE: There is a flow restrictor provided. Be sure not to lose it when unwrapping the diverter vavle.

To stop the flow through the filter, turn off the faucet or turn the lever in the opposite direction. 10. Adjust the hose length to accommodate the cover. Be sure not to pull the hose too tightly over the filter cartridge as this may restrict flow. 11. Run water through the filter for 5 minutes to remove any small carbon particles and expel excess air.

 12. The Wand will dispense water in either a steady stream or a spray. To switch between stream and spray, rotate the collar at the end of the Wand. Using the Flow Restrictor, thread the diverter valve onto the faucet, “hand–tighten” only. Do not over tighten as it could damage the threads.



NOTE: For best results, after sitting overnight or after several hours of non-use, run water through the filter for 1 minute before using.

NOTE: if the diverter valve is not compatible with your faucet, contact your local Customer Service to obtain assistance.

10

11

EN 13. Charge the system. To improve the flow rate and to reduce the “run on” of water after the faucet is turned off the system needs to be “charged”. Charging purges trapped air from the system.





Pour water into the top hole to fill the Nano Ceram cartridge.

Re-install the pre-filter cartridge and again pour in water into the top hole of the pre-filter cartridge until it is full.

Model UCU-200 CAL Installation/Operation

Reinsert the inlet assembly as indicated in step 6. Your system is now charged and ready to use. If you notice that the water flow continues for more than a few seconds, charge the system again to remove any residual trapped air.

14. Place the cover on the base assembly Your Rena Ware AquaNano Water Filter is now ready for you to enjoy!

12

13

EN INSTALLATION ASSEMBLY BOX

Packing/Product Diagrams

8. 9. 10. 11. 12. 13. 14. 15. 16.

FAUCET ASSEMBLY BOX 1. 2. 3. 4. 5. 6. 7.

Faucet body Spray head Pull-out hose Data Cable Bag with weight & spring clip. Bag with rubber gasket, lock washer & brass nut. Bag with brass filter out- line connector & plastic filter in-line connector

7

Inlet Assembly (including Inlet Tube and Outlet Tube) Back Flush Adapter (for use on the Pre-Filter Cartridge only) Filter Base Locking Plate Battery Door (Batteries not included) Data Cable Port NanoCeram® Cartridge Reusable Pre-Filter Housing (includes one EM Media Insert) 2 disposable EM Media Inserts 9 8

1 13 11

6 12

10

3

FILTER CARTRIDGES 14

4

16 15

2

5 If any of these items are missing, please contact Rena Ware Customer Service 14

15

EN

Installation/Operation INSTALLING PULLOUT KITCHEN FAUCET 1. WARNING: Read all the instructions completely before proceeding. Rena Ware recommends calling a professional if you are uncertain about installing this product! This product should be installed in accordance with all local and state plumbing and building codes.

4. INSTALLING OPTIONAL DECK PLATE: (For single post mount, go to step 7) Place screws (4A) into Deck Plate slots. Set plastic bottom plate (4B) over the center hole on the sink, rounded edges up. Put a bead of plumbers’ putty around the inside bottom edge of Deck Plate (4C). Install the Deck Plate (4C) over the three holes in your sink.

4C

2. SHUT OFF WATER SUPPLY: Locate water supply inlets and shut off the water supply valves. These are usually found under the sink or near the water meter. If you are replacing an existing faucet, remove the faucet from the sink and clean the sink surface thoroughly.

4A

4B 4A

3. TOOLS RECOMMENDED: Plumber’s putty, slotted screwdriver, pliers, adjustable wrench, flashlight, and cloth. Your installation may require new supply lines and/or shut-off valves or other additional tools.

DO NOT USE TEFLON TAPE FOR ANY CONNECTIONS

5. SECURING DECK PLATE TO DECK: From underneath sink, hand-tighten wing nuts (5A). Caution: do not over tighten wing nuts. Remove any excess putty from around the outside edge of the Deck Plate (5B). (For 1-hole installation using the single post: Go To Step 7)

5A

5B 5A

16

17

EN 6. INSTALLING THE FAUCET USING DECK PLATE: YOU WILL NEED TWO PEOPLE FOR INSTALLATION. Insert the faucet supply tubes (6A) and hose (6B) through the optional Deck Plate. Pull the pull-out hose out so that it’s end is above the ends of the supply tubes (see inset diagram below). This will make the installation of the washers and lock nut much easier From underneath the sink, place large rubber gasket (6C), lock washer (6D) and large brass nut (6E) over supply tubes (6A), hose (6B), and data cable (6F). Thread loosely onto faucet shank (6G).

CAUTION: To avoid cutting the data cable and disabling the indicator lights make sure that before tightening anything you first front-align the faucet body so that “Rena Ware” is centered and the spout and handle swing equally to the right and left. Once aligned, have one person hold the faucet firmly in place while the other person tightens the faucet to the sink. Adjusting the faucet after tightening to the sink will cut the data cable. Tighten faucet firmly to sink. Note: do not remove thin protective plastic bag (6H). Thread the connector (6I) onto hose (6B) and tighten.

7. SINGLE POST MOUNT INSTALLATION: YOU WILL NEED TWO PEOPLE FOR INSTALLATION. (Do not use optional Deck Plate, plastic bottom plate, screws, or wing nuts.) Insert Supply Tubes (7A), Hose (7B), and Data Cable (7C) through center hole of sink. Pull the pull-out hose out so that it’s end is above the ends of the supply tubes (see inset diagram below). This will make the installation of the washers and lock nut much easier. From underneath the sink, place large rubber gasket (7D), lock washer (7E) and large brass nut (7F) over Supply Tubes (7A), Hose (7B), and data cable (7C). Thread loosely onto faucet shank (7G).

CAUTION: To avoid cutting the data cable and disabling the indicator lights make sure that before tightening anything you first front-align the faucet body so that “Rena Ware” is centered and the spout and handle swing equally to the right and left. Once aligned, have one person hold the faucet firmly in place while the other person tightens the faucet to the sink. Adjusting the faucet after tightening to the sink will cut the data cable. Tighten faucet firmly to sink. Note: Do not remove thin protective plastic bag (7H). Thread the connector (7I) onto hose (7B) and tighten.

6H 6G

7H

6C

7G

6D

6E

7D

7E

7F

6B

6F 7B

7C

6A 7A

6I 7I 18

1919

EN 8. WATER SUPPLY CONNECTIONS: Gently separate hot and cold Supply Tubes (8A), approximately three inches apart. Connect Water Supply Lines (8C) to Faucet Inlets (8B). (Supply Lines and fittings are not included.)

10. INSTALL THE FILTER CARTRIDGES: Once inserted into the base, rotate the NanoCeram® Cartridge clockwise slightly to lock. The Pre-Filter Cartridge inserts into the locking plate at the top of the NanoCeram® Cartridge the same way.

8A

8B



8C

9. ATTACHING INSTALLATION ASSEMBLY:

a. Install two new, high quality, AA batteries (not included) in the Filter Base. Insert the Data Cable into the Data Cable Port on the underside of the base.

data cable port





*IMPORTANT: When the batteries (not included) are installed, the replacement lights will fire a test sequence. If all lights do not light, you may have a broken wire on installation. data cable

b. Insert the Filter Outlet Line (9D) into the connector on the pull-out hose (9E).

11. ATTACH THE INLET ASSEMBLY: The Inlet Assembly attaches to the top of the Pre-Filter Cartridge. It is inserted the same way the cartridges connect. Rotate the Inlet Assembly approximately 1/8 turn clockwise so that the hose at the wand side of the filter lines up with the wand stem.

9E

9D

20

21

EN 12. UNIT START UP: Turn on hot and cold water supplies, and check for leaks above and below the sink.

14. CHARGE THE SYSTEM. To improve the flow rate and to reduce the “run on” of water after the faucet is turned off the system needs to be “charged”. Charging purges trapped air from the system.

Run water through the system for about a minute to saturate the media. Remove the pre-filter cartridge being careful to minimize the water that spills onto the base unit.

13. FLUSHING THE FAUCET: To remove any small carbon particles and expel excess air, it will be necessary to flush the faucet. Remove plastic bag (13A) from the end of the hose (13B). Lift the faucet handle (13C) up to the full on position. Run water for 10 minutes alternating between the side faucet and filter to check for leaks.



Pour water into the top hole to fill the Nano Ceram® cartridge.



Re-install the pre-filter cartridge and again pour in water into the top hole of the pre-filter cartridge until it is full.

13C

13B



13A

22

23

EN 15. INSTALLING THE SPRAY HEAD: Do not let hose (15C) retract into Faucet arm (15A). Connect the spray head (15B) to the pull-out hose (15C) by turning the metal hose fitting (15D) clockwise, hand tighten. CAUTION: do not over tighten.

17. SECURING INLET LINES: Do not cross the pullout hose (17B) with the inlet supply tubes (17A) to avoid binding, jamming and interference with the movement of the pull-out hose. NOTE: For best results, after sitting overnight or after several hours of non-use, run water through the filter for 1 minute before using.

15C

Your Rena Ware AquaNano Water Filter is now ready for you to enjoy!

15A 15D

Accessories 15B Stage Zero Filter In areas where the amount of sediments in the water is very high, the Pre-Filter cartridge can clog quicker than expected. The Stage Zero external filter removes the larger particles to prevent this from happening. 16. ATTACHING WEIGHT TO PULLOUT HOSE: Your faucet includes a weight, to help to retract the hose during pullout operation. Attach weight (16A) to the hose using spring clip (16B) at the lowest point on the hose (16C).

It can be easily back-flushed and replaced to allow your Aqua  Nano system to filter the very small things it was designed to remove and let you go longer between PreFilter back-flushes and NanoCeram cartridge replacements. Mounting Bracket You may place the entire under-the-counter assembled filter on a bracket mounted to the wall to raise if off the floor of your sink cabinet. Side Faucet

16C 16A

16B 16A

24

16B

To extend the life of the Aqua  Nano UCU-200 filter cartridges, you may wants to use unfiltered water for tasks such as dishwashing, household cleaning or watering plants that do not require filtration. The side faucet will allow you to bypass the filter and have a source of unfiltered water at the kitchen sink.

25

17B

17A

EN

Care & Maintenance Cleaning the Exterior of the AquaNano To clean the exterior of your filter, use a clean, damp cloth and mild, nonabrasive soap. To clean the exterior of your faucet, filter cartridges, and base unit, use a clean, damp cloth and mild, non-abrasive liquid soap. Do not use dishwashing soap. Wipe down with cloth. Use of polish, detergents, abrasives, cleaners, organic solvents, or acid may cause damage. USE OF OTHER THEN A DAMP SOFT CLOTH AND MILD LIQUID SOAP WILL VOID YOUR WARRANTY.

NOTE: DO NOT SUBMERGE CTU OR UCU UNIT OR LET STAND IN WATER. EXCESSIVE MOISTURE INSIDE THE UNIT WILL DAMAGE IT AND VOID THE WARRANTY.

Non-Functioning Flow Meter If the electronic flow meter stops functioning, reset the meter by using the following procedures: 1. Remove the battery compartment door in the bottom of the base by unscrewing the two screws and by gently prying the door open using a flat screwdriver at the point shown in the diagram.

Replacement Indicator Lights

2. Remove the old batteries, wait 20 seconds, and then replace with two new high quality AA batteries. 3. Replace the NanoCeram® filter cartridge. 4. The unit will reset to its default settings.

UCU-200 CAL

CTU -200 CAL

Your AquaNano features a visual flow meter integrated into the base of the faucet. When water is flowing through your filter, LED (light emitting diode) lights will flash to indicate the following: •

F I LT E R I N G The blue light indicates that the unit is functioning normally.



R E O R D E R The yellow warning light lets you know approximately 1,893

liters (500 gallons) of life is left in the NanoCeram® Cartridge. Contact your Rena Ware Consultant or Rena Ware Customer Service Center to order a replacement. The blue F I LT E R I N G light also indicates that your filter is still working. •

R E P L AC E The red warning light indicates the NanoCeram® Cartridge’s

effective life has ended. The blue F I LT E R I N G light will not illuminate. Replace the NanoCeram® Cartridge before continuing to use your filter.

26

27

EN 5. Invert the Pre-Filter cartridge and place the Back-Flow Adaptor on the outlet nipple of the Pre-Filter.



Back-Flushing, cleaning & replacing the Pre-Filter EM Media and the NanoCeram® Cartridge To properly maintain the Pre-filter, it should be regularly back-flushed and cleaned (up to 3 times) whenever an important reduction in the flow occurs. The disposable EM Media Insert should be replaced when these procedures fail to restore acceptable flow. NOTE: The back-flushing process will require two people. NEVER BACK-FLUSH THE NANOCERAM® CARTRIDGE. BACK-FLUSHING THE NANOCERAM® CARTRIDGE WILL DAMAGE THE INTERNAL STRUCTURE CAUSING THE FILTER TO BE INEFFECTIVE. BACK-FLUSHING THE NANOCERAM® CARTRIDGE CAN ALSO CONTAMINATE THE MEDIA DOWNSTREAM OF NANOCERAM® MEDIA IF DAMAGED, IT WILL NO LONGER FILTER THE WATER.

1. Make sure the water is turned off.

6. Insert the outlet nipple of the Inlet Assembly into the other end of the Back-Flush Adapter and keep pressure on it. Hold the inverted Pre-Filter over the sink, a bucket or some other receptacle that can hold at least 2 gallons (7.5 liters).



 2. Remove the back-flow adapter from the Inlet Assembly.

7. Have a second person turn on the water. When the water is turned on, there will be a small amount of back pressure forcing the Inlet Assembly out of the Back-Flush Adapter so you must hold the Inlet Assembly, BackFlush Adapter, and Pre-Filter together to keep pressure on it and keep them from coming apart. 3. Remove the Inlet Assembly by turning it counterclockwise until it releases.

8. Allow the water to run for 5 minutes, shake the cartridge and tap it against the sink until the flow rate has increased 9. Open the housing by turning the top counterclockwise

4. Remove the Pre-Filter Cartridge from the NanoCeram® Cartridge by turning it counterclockwise until it releases. 28

29

EN 10. To remove the media insert from the housing, grab the base of the housing with both hands and push the end cap of the media insert forward using your thumbs. Once loose discard or rinse off.



Temporarily reconnect the inlet assembly to the filter base. Wash the reusable housing and rinse off the media insert with water and dry. When washing the media mild rubbing is acceptable. If the exterior of the media is scrubbed too hard it can be damaged permanently. DO NOT USE SOAP.

11. Insert the Media with the outlet nipple pointing down and the punt up.

NOTE: The Pre-Filter and the NanoCeram® are not necessarily replaced at the same time and the led indicator lights refer only to the NanoCeram® cartridge, therefore, replace it when the flow meter’s red warning light flashes. It will also be time to replace your batteries. 13. Repeat Step #3. For the NanoCeram® remove the cartridge by turning it counterclockwise until it releases and discard used cartridge.

14. Remove the battery compartment door in the bottom of the base by unscrewing the two screws and by gently prying the door open using a flat screwdriver.

12. Close the housing by turning the top clockwise until the arrows marked on the housing are almost aligned and reinstall. 15. Remove the old batteries, wait 20 seconds, and then replace with two new high quality AA batteries. This will reset the flow meter to “0” and the LED lights will start flashing again when water is flowing through the filter. 16. Unpack the new NanoCeram® Cartridge and install, charge both cartridges, and reassemble as detailed in the “SET UP” section. NOTE: Note that back-flushing and rinsing will improve flow but will not restore the Pre-Filter cartridge to “like new” condition. The improvement will be less each time you back-flush and rinse, until it is necessary to replace the Pre-Filter cartridge to restore the flow rate to an acceptable level. 30

17. Run water for 2 minutes, to remove any carbon particles and expel any trapped air.

31

EN

Troubleshooting

Replacement Parts

1. Water is not coming out of the UCU-200 spray faucet head…

NOTE: Always use genuine Rena Ware replacement parts.

• Make sure the source water valves are turned on. • Make sure the tubing is smooth and straight, without kinks. 2. Water is not coming out of the CTU-200 wand… • Turn the diverter valve to the proper “on” position.

Contact your Rena Ware Representative or the Rena Ware Customer Service Center near you to order replacement parts for your AquaNano Water Filter. You may also visit Rena Ware on the worldwide web at www.renaware.com for information on our Service Centers and products.

• Remove the diverter valve and make sure the flow regulator is placed in the right position and is not blocked by any residue.

NanoCeram® Cartridge

• Make sure the tubing is smooth and straight, without kinks.

Diverter Valve

3. Water leaks out from between the filter cartridges or at the filter inlet assembly or filter base…

Pre-Filter Housing EM Media Insert

• Separate the cartridges at the point of the leak. Each of the cartridges, and the filter inlet, should have two o-rings on the raised outlet found between the three feet. Check to ensure that the o-rings are in place and properly seated in the grooves provided for them. 4. Water leaks from the tubing… • For CTU-200 model: If water is leaking at the diverter valve, unscrew the collar at the inlet of the diverter valve and push the tubing firmly over the diverter valve barb. Make sure the inlet tube is attached to the barb of the diverter valve. Slide the collar back along the tubing to the diverter inlet and screw it in place firmly. • For both CTU & UCU-200 models: Check the tubing for cuts or nicks. 5. Water continues to flow out of the spray head after water is turned off… • Water may continue to flow from the spray head for a short time due to a build-up of pressure within the filter but will typically stop by itself. • Trapped air in the filter may force water out after the tap has been turned off. To eliminate the trapped air, fill the Cartridges with water until you see water leaking through the top hole of the Cartridges. This is known as “charging” the cartridge and is done manually with the inlet assembly removed from the top of the filter cartridge. See “Charging the system”. 6. Lights on the Faucet Collar or the base of the filter do not work . . .

Specifications AquaNano Maximum Operating Pressure

690 kPa (100 psi)

Minimum Operating Pressure

207 kPa (30 psi)

Maximum Water Temperature

38°C (100°F)

Minimum Water Temperature

4°C (40°F) 5.68 LPM (1.5 GPM)

Filtered Water Flow Rate @ 60 psi

• Make sure that the Data Cable is properly plugged into the Data Port. NanoCeram® Cartridge Capacity

• Check batteries.

11,355 L (3,000 GAL) or 1 year



32

33

Warranty

SP

The AquaNano Limited Warranty Rena Ware warrants its AquaNano water filtration systems to be free from defects in materials and workmanship for one year from the date of purchase. This Product is for home use on municipally treated water only. The Warranty does not cover damage resulting from use of the Product on water having high chemical interference, suspended materials or visual solids. The Warranty does not cover normal wear and tear of valving connections, o-rings, rubber and plastic parts, or filter cartridges. The Warranty does not cover defects resulting from misuse, abuse, negligence, accident, use of the Product in a manner other than as described in the instructions and on the specifications label, repairs or alteration outside a Rena Ware facility, or lack of maintenance. Use of replacement parts other than genuine Rena Ware replacement parts or removal of the specifications label will void this Warranty. The Warranty does not cover incidental or consequential damages resulting from the use of this Product.

CONTENIDO

Remedy in the Event of Warranty Claim

Diagrama del producto ............................................................................. 46 Instalación/funcionamiento .................................................................... 48

At its option, Rena Ware will repair or replace a Product, or any part thereof, which is determined to be defective. If a replacement is made, the Product for which the replacement is made becomes the property of Rena Ware. This

remedy shall be the exclusive remedy available. To Obtain Warranty Service

To obtain warranty service, send a detailed written description of the claimed defect to the closest Rena Ware Service Center. You may be required to return the Product, at your expense, to the nearest Rena Ware Service Center in order to obtain warranty service. You may also be required to provide proof of purchase. If, after inspection, Rena Ware determines that a covered defect exists, Rena Ware will bear the cost of return delivery.

Introducción ........................................................................................................ 36 Características ................................................................................................... 37 Medidas de seguridad .................................................................................. 37 CTU 200................................................................................................................... 38

Diagrama del producto ............................................................................ 39 Instalación/funcionamiento..................................................................... 40

UCU 200 ................................................................................................................. 45

Accesorios.............................................................................................................. 57 Cuidado y mantenimiento del CTU 200 y UCU 200 ......................... 58 Luces indicadoras de reemplazo ............................................................... 58 Medidor de flujo no funciona ..................................................................... 59 Lavado con flujo invertido a presión, limpieza y reemplazo del prefiltro EM y del cartucho NanoCeram® ........................................................................................................ 60

Other Warranty Limitations

Resolución de problemas ........................................................................... 64

This Warranty is in lieu of all other express warranties. Any implied warranty shall be equal in duration to the above express Warranty. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, or do not allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights. You may also have other rights which vary from jurisdiction to jurisdiction. This Warranty applies to AquaNano water filtration systems only. Separate warranties apply to other Rena Ware products.

Repuestos ............................................................................................................ 65

34

Especificaciones................................................................................................. 65 Garantía.................................................................................................................. 66

35

Introducción

Características

Ya posee uno de los sistemas de filtración de agua más avanzados disponibles en el mundo. El AquaNano utiliza tecnología electropositiva como parte de un sistema de filtración en etapas múltiples de alto flujo con caída de presión limitada. Este sistema multifuncional único le brinda a usted y a su familia agua filtrada a bajo costo directo del grifo: • Etapa 1: Prefiltración - La prefiltración elimina los sólidos suspendidos de mayor tamaño, lo que extiende considerablemente la vida de su cartucho NanoCeram®. • Etapa 2: Filtración electropositiva - La segunda etapa utiliza medios de filtración electropositiva NanoCeram® patentados con capacidad de absorción de impurezas y eficiencia en filtración de partículas pequeñas hasta de un nanómetro o .001 micrones. • Etapa 3: Tecnología avanzada de bloque de carbón - La tercera etapa utiliza tecnología de bloque de carbón y un medio absorbente especial para absorber y reducir cloro, plomo, sabores y olores. El AquaNano incluye un medidor de flujo electrónico que le indicará cuándo debe ordenar y reemplazar el cartucho NanoCeram®.

NSF International Sistema probado y certificado por NSF International en conformidad con la norma NSF/ANSI 42 y 53 para la reducción de cloro, plomo y quistes. Números de registro del Estado de California:

14-3018, 14-3019

• El AquaNano incluye un práctico cabezal tipo lluvia/chorro para apuntar el agua a donde desee, lo cual facilita el llenado de botellas y envases y el lavado de frutas y vegetales. • El medidor de flujo indica cuándo debe reemplazar el cartucho NanoCeram®, para garantizar que tenga agua filtrada ininterrumpidamente. • El AquaNano filtrará agua efectivamente hasta un año o 3,000 galones/11,355 litros, lo que ocurra primero.

Medidas De Seguridad •

Este filtro es de uso doméstico y está diseñado para filtrar el agua tratada por la municipalidad.

• ∆ ADVERTENCIA: No se utilice con agua que no sea segura desde el punto de vista microbiológico o cuya calidad se desconozca sin la debida desinfección. Reemplace siempre el cartucho del filtro NanoCeram® cuando la luz indicadora roja se encienda. • El cartucho NanoCeram® del AquaNano tiene una capacidad nominal de 11,355 litros (3,000 galones) o un año, lo que ocurra primero. El cartucho NanoCeram® se debe reemplazar cuando la luz indicadora roja se encienda. La capacidad real dependerá de la cantidad de sólidos y partículas suspendidos en el sistema de agua de su localidad. En algunos suministros de agua, los olores y sabores pueden regresar o el flujo puede reducirse antes de alcanzar la capacidad nominal. En estos casos, el cartucho NanoCeram® se debe reemplazar con mayor frecuencia. • Es muy importante cumplir con las instrucciones de uso y mantenimiento aquí contenidas para lograr un óptimo desempeño. El incumplimiento de las instrucciones de uso y mantenimiento anulará la garantía. • No se use con agua a una temperatura inferior a 4˚C (40˚F). NOTA: Contaminantes u otras sustancias que este dispositivo para el tratamiento del agua elimine o reduzca no se encuentran necesariamente en su agua.

36

SP

Se debe cumplir con las normas de uso y mantenimiento.

37

Diagrama del producto

1. 2.

Tapa Alojamiento reusable del prefiltro



(incluye un elemento desechable EM)

3. 4. 5.

Cartucho del filtro NanoCeram® Caja de entrada (incluye manguera) Adaptador de flujo invertido

SP

1

(solo para usar con el cartucho del prefiltro) 6. Válvula de desviación 7. Junta de la válvula de desviación 8. Base 9. Placa de seguridad 10. Varilla 11. Tapa del compartimiento de las baterías (baterías AA no incluidas) 12. Dos elementos desechables EM

5 4

2 12

10 3 11 9 7 6

Modelo CTU-200 CAL Instalación/Funcionamiento 38

8

Figura 1 Comuníquese con el Servicio al Cliente de Rena Ware si no recibe alguno de estos artículos. 39

Instalación/Funcionamiento

SP



Saque el AquaNano y los cartuchos de sus cajas, retire los materiales de embalaje y compare el contenido de las cajas con el diagrama del producto. (Figura 1)

5. Se puede ajustar la longitud de la manguera entre la caja de entrada y la válvula de desviación, de ser necesario. Inserte la manguera en la base por la entrada ubicada en la parte trasera y sáquela por la boca de entrada para alargarla.

1. Abra la tapa de la base del filtro. 2. Instale dos baterías AA nuevas de buena calidad (no incluidas) en la base del filtro.



3. Saque el cartucho NanoCeram® y el cartucho del prefiltro de sus bolsas plásticas. 4. Para instalar el cartucho NanoCeram®, colóquelo en la placa de seguridad que está en la base y gírelo ligeramente en sentido de las manecillas del reloj para asegurarlo en posición. Inserte el cartucho del prefiltro en la placa de seguridad sobre el cartucho



También puede insertar la manguera en la base por la boca de entrada y sacarla por la entrada ubicada en la parte trasera para acortarla. Asegúrese de que la manguera no quede muy ajustada sobre el cartucho del filtro ya que podría reducir el flujo.

NanoCeram® de la misma forma.



etiqueta







6. La caja de entrada se conecta encima del cartucho del prefiltro. Se inserta de la misma forma en que se conectan los cartuchos. Gire la caja de entrada aproximadamente 1/8 en sentido de las manecillas del reloj para que la manguera del lado de la varilla del filtro esté alineada con la boquilla de la varilla.



etiqueta

40

41

9. Coloque el AquaNano sobre una superficie plana del mueble de la cocina, cerca del fregadero. Con la varilla apuntando hacia el fregadero, abra la llave de agua y desvíe el agua hacia el filtro girando la palanca de la válvula de desviación 90 grados. Compruebe que no haya fugas.



7. Con la ayuda de un alicate o alicate de sujeción, retire el aireador instalado en su grifo.

8. Quite la envoltura protectora de la válvula de desviación. NOTA: Se incluye un reductor de flujo. Tenga cuidado de no desecharlo inadvertidamente cuando saque la válvula de desviación de su bolsa.

Para detener el flujo a través del filtro, cierre la llave de agua o gire la palanca en dirección contraria. 10. Ajuste la longitud de la manguera para que encaje la tapa. Asegúrese de no ajustar demasiado la manguera sobre el cartucho del filtro, ya que esto puede reducir el flujo. 11. Deje correr agua a través del filtro por cinco minutos para eliminar partículas pequeñas de carbón y exceso de aire.

 12. La varilla surtirá agua en chorro o tipo lluvia. Para cambiar entre los dos tipos, gire el cuello por el borde de la varilla. Coloque el reductor de flujo y enrosque la válvula de desviación en el grifo apretándola con la mano. No la apriete demasiado, ya que podría dañar la rosca.

NOTA: Para obtener mejores resultados, a primera hora del día o después de varias horas sin uso, haga correr agua por el filtro por un minuto antes de usarlo.

Nota: Si la válvula de desviación no es compatible con su grifo, comuníquese con el Servicio al Cliente de su localidad para obtener ayuda.

42

43

SP

13. Cargue el sistema. Para mejorar el flujo y reducir la “fuga” de agua luego de cerrar la llave de agua, se debe “cargar” el sistema, ya que esto purga el aire atrapado en el mismo.



SP

Vierta agua por el orificio superior para llenar el cartucho NanoCeram®.



Vuelva a instalar el cartucho del prefiltro y vierta agua nuevamente por el orificio superior de este hasta llenarlo.

Modelo UCU-200 CAL Instalación/Funcionamiento

Vuelva a colocar la caja de entrada tal como se indica en el paso 6. Su sistema ya está cargado y listo para usar. Si sigue saliendo agua por varios segundos, cargue el sistema de nuevo para eliminar el aire que pueda estar atrapado dentro.

14. Coloque la tapa en la base. ¡Ya puede usar su filtro de agua AquaNano de Rena Ware!

44

45

EN CAJA CON LAS PIEZAS DE INSTALACIÓN

Diagrama del empaque/producto

8. Caja de entrada (incluye tubo de entrada y tubo de salida) 9. Adaptador de flujo invertido (solo para usar con el cartucho del prefiltro) 10. Base del filtro 11. Placa de seguridad 12. Tapa del compartimiento de las baterías (no incluye baterías) 13. Puerto del cable de datos 14. Cartucho NanoCeram® 15. Alojamiento reusable del prefiltro (incluye un elemento reemplazable EM) 16. 2 Elementos reemplazables EM

CAJA CON LAS PIEZAS DEL GRIFO 1. Cuerpo del grifo 2. Cabezal aspersor 3. Manguera extraíble 4. Cable de datos 5. Bolsa con contrapeso y anillo de cierre 6. Bolsa con empacadura de goma, arandela de seguridad y tuerca de bronce

7

7. Bolsa con conector externo de bronce y conector interno de plástico

9 8

1

13

6

11 12

10 3 CARTUCHOS DEL FILTRO 14 4

2

16 15

5 Comuníquese con el Servicio al Cliente de Rena Ware si no recibe alguno de estos artículos.

46

47

SP

Instalación/Funcionamiento INSTALACIÓN DEL GRIFO DE COCINA EXTRAÍBLE 1. ADVERTENCIA: Lea todas las instrucciones antes de comenzar. ¡Rena Ware recomienda llamar a un profesional si no está seguro de cómo instalar este producto! El filtro se debe instalar de conformidad con las normas de plomería y construcción locales y estatales.

4. INSTALACIÓN DE LA PLACA BASE OPCIONAL: (Vaya al paso 7 para instalaciones con un solo orificio). Coloque los tornillos (4A) en los orificios de la placa base. Coloque la placa inferior de plástico (4B) sobre el orificio central del fregadero, con los bordes redondeados hacia arriba. Coloque un poco de masilla de plomero alrededor del borde inferior interno de la placa base (4C). Instale la placa base (4C) sobre los tres orificios del fregadero.

2. CIERRE LA LLAVE DE PASO DE AGUA: Ubique las entradas de suministro de agua y cierre las llaves de paso. Por lo general se encuentran debajo del fregadero o cerca del medidor de agua. Si va a reemplazar un grifo, retírelo y limpie bien la superficie del fregadero.

4C 4A

4B 4A

3. HERRAMIENTAS RECOMENDADAS: Masilla de plomero, destornillador punta plana, alicates, llave ajustable, linterna y paño. Es posible que la instalación requiera nuevas líneas de suministro y/o llaves de cierre o herramientas adicionales.

NO USE CINTA DE TEFLÓN EN LAS CONEXIONES

5. SUJECIÓN DE LA PLACA BASE A LA SUPERFICIE: Apriete manualmente las tuercas mariposa (5A) desde la parte inferior del fregadero. Advertencia: No apriete demasiado las tuercas mariposa. Quite el exceso de masilla alrededor del borde externo de la placa base (5B). (Vaya al paso 7 para instalaciones con un solo orificio).

5A

5B 5A

48

49

SP

EN 6. INSTALACIÓN DEL GRIFO CON PLACA BASE: SE NECESITAN DOS PERSONAS PARA REALIZAR ESTE PROCEDIMIENTO. Inserte los tubos de suministro del grifo 6A) y la manguera (6B) por la placa base opcional. Hale la manguera extraíble de manera que su extremo quede por encima de los tubos de suministro (vea el dibujo). Esto facilitará la instalación de las arandelas y la contratuerca. Desde la parte inferior del fregadero, pase la empacadura de goma grande (6C), la arandela de seguridad (6D) y la tuerca de bronce grande (6E) sobre los tubos de suministro (6A), la manguera (6B) y el cable de datos (6F). Enrosque ligeramente al vástago del grifo (6G).

ADVERTENCIA: Para evitar cortar el cable de datos y desactivar las luces indicadoras, antes de ajustar cualquier pieza asegúrese de que el cuerpo del grifo esté alineado al frente de manera que “Rena Ware” esté centrado y el grifo y la manilla se muevan en ambos sentidos. Una vez alineado, pídale a otra persona que sostenga el grifo firmemente mientras usted instala el grifo en el fregadero. Si ajusta el grifo luego de instalarlo en el fregadero cortará el cable de datos. Ajuste bien el grifo al fregadero. Nota: No quite la bolsa plástica protectora (6H). Enrosque el conector (6I) a la manguera (6B) y apriételo.

7. INSTALACIÓN CON UN SOLO ORIFICIO: SE NECESITAN DOS PERSONAS PARA REALIZAR ESTE PROCEDIMIENTO. (No use la placa base opcional, la placa inferior de plástico, los tornillos ni las tuercas mariposa). Inserte los tubos de suministro (7A), la manguera (7B) y el cable de datos (7C) a través del orificio central del fregadero. Hale la manguera extraíble de manera que su extremo quede por encima de los tubos de suministro (vea el dibujo). Esto facilitará la instalación de las arandelas y la contratuerca. Desde la parte inferior del fregadero, pase la empacadura de goma grande (7D), la arandela de seguridad (7E) y la tuerca de bronce grande (5F) sobre los tubos de suministro (7A), la manguera (7B), y el cable de datos (7C). Enrosque ligeramente al vástago del grifo (7G).

ADVERTENCIA: Para evitar cortar el cable de datos y desactivar las luces indicadoras, antes de ajustar algunas de las piezas, asegúrese de que el cuerpo del grifo esté alineado al frente de manera que “Rena Ware” esté centrado y el grifo y la manilla se muevan en ambos sentidos. Una vez alineado, pídale a la otra persona que sostenga el grifo firmemente mientras usted instala el grifo en el fregadero. Si ajusta el grifo luego de instalarlo en el fregadero cortará el cable de datos. Ajuste bien el grifo al fregadero. Nota: No quite la bolsa plástica protectora (7H). Enrosque el conector (7I) a la manguera (7B) y apriételo.

6H 6G

7H

6C

7G

6D

6E

7D

7E

7F

6B

6F

7B

7C

6A

7A 7I

6I 50

51

SP

8. CONEXIONES DE SALIDA DE AGUA: Separe cuidadosamente las canillas de agua caliente y fría (8A), aproximadamente 3 pulgadas (7.6 cm). Conecte las líneas de suministro de agua 8C) a las entradas de la llave de agua (8B). (Las líneas de suministro y los accesorios de instalación no están incluidos).

10. INSTALACIÓN DE CARTUCHOS DEL FILTRO: Luego de insertar el cartucho NanoCeram® en la base, gírelo ligeramente en sentido de las manecillas del reloj para que calce bien. El cartucho del prefiltro se inserta en la placa de seguridad encima del cartucho NanoCeram® de la misma forma.

8A

8B



8C

9. INSTALACIÓN DEL UTILLAJE:

a. Instale dos baterías AA nuevas de buena calidad (no incluidas) en la base del filtro. Conecte el cable de datos al puerto del cable de datos que se encuentra en la parte inferior de la base. *IMPORTANTE: Cuando instale las baterías (no incluidas), las luces indicadoras de reemplazo activarán una secuencia de prueba. Si no se encienden todas las luces, quizás haya un cable roto.



Cable de datos

b. Introduzca la línea de salida del filtro (8D) en el conector de la manguera extraíble (8E).



Puerto de cable de datos

11. INSTALACIÓN DE LA CAJA DE ENTRADA: La caja de entrada se coloca encima del cartucho del prefiltro. Se inserta de la misma forma en que se conectan los cartuchos. Gire la caja de entrada aproximadamente 1/8 en sentido de las manecillas del reloj para que la manguera del lado de la varilla del filtro quede alineada con la boquilla de la varilla.

8E

8D

52

53

SP

12. PUESTA EN FUNCIONAMIENTO DE LA UNIDAD: Abra las llaves de paso de agua caliente y fría y compruebe que no haya fugas encima ni debajo del fregadero.

14. CARGA DEL SISTEMA. Para mejorar el caudal y reducir la “fuga” de agua luego de cerrar la llave de agua, se debe “cargar” el sistema, ya que esto purga el aire atrapado en el mismo. Deje correr agua por el sistema durante un minuto aproximadamente para saturar el cartucho del prefiltro y luego sáquelo con cuidado para no derramar agua en la base de la unidad.



13. LAVADO DEL GRIFO A PRESIÓN: Para eliminar partículas pequeñas de carbón y exceso de aire, deberá dejar correr agua por el grifo. Retire la bolsa plástica (12A) del extremo de la manguera (12B). Levante la palanca del grifo (12C) por completo y deje correr agua por 10 minutos alternando entre el grifo lateral y el filtro para comprobar si hay fugas.



Vierta agua por el orificio superior para llenar el cartucho NanoCeram®.

13C

Vuelva a instalar el cartucho del prefiltro y vierta agua nuevamente por el orificio superior del cartucho del prefiltro hasta llenarlo. 13B

13A

54

55

SP

15. INSTALACIÓN DEL CABEZAL ASPERSOR: No permita que la manguera (15C) se retraiga al brazo del grifo (15A). Conecte el cabezal aspersor (15B) a la manguera extraíble (15C) girando el conector de la manguera (15D) en sentido de las manecillas del reloj y apriete manualmente. ADVERTENCIA: No lo apriete demasiado.

17. SUJECIÓN DE LÍNEAS DE ENTRADA: No cruce la manguera extraíble (16B) con los tubos de suministro de entrada (16A) para evitar atascar, obstaculizar u obstruir la manguera extraíble. NOTA: Para obtener mejores resultados, a primera hora del día o después de varias horas sin uso, haga correr el agua por el filtro por un minuto antes de usarlo.

15C

¡Ya puede usar su filtro de agua AquaNano de Rena Ware!

15D

Accesorios Filtro Etapa Cero En áreas en las cuales la acumulación de sedimentos en el agua es muy alta, el cartucho del Pre-filtro pudiera obstruirse más rápido de lo esperado. El filtro externo Etapa Cero ayuda a prevenir que esto ocurra al atrapar las partículas más grandes. 16. INSTALACIÓN DEL CONTRAPESO A LA MANGUERA EXTRAÍBLE: El grifo incluye un contrapeso que facilitará la retracción de la manguera. Instale el contrapeso (15A) a la manguera con la abrazadera de ballesta (15B) en el punto más bajo de la manguera (15C).

Puede ser fácilmente lavado a flujo invertido a presión y reemplazado para permitir a su sistema Aqua √ Nano filtrar las partículas minúsculas para lo que está diseñado y le perrmite una mayor duración entre lavados a flujo invertido a presión del Pre-filtro y reemplazos del cartucho NanoCeram®. Soporte opcional Puede colocar toda la instalación del filtro debajo del fregadero sobre un soporte instalado en la pared para separarlo del piso del gabinete del fregadero.

16C

Grifo Lateral 16A

16B 16A

56

16B

17B

17A

15A

15B

SP

Para prolongar la vida de los cartuchos del filtro Aqua Nano UCU- 200, debería usar agua sin filtrar para lavar los platos, limpiar la casa y regar las plantas, tareas que no requieren agua filtrada. El grifo lateral le permitirá circunvalar el filtro y tener agua sin filtrar en el fregadero de la cocina.

57

Cuidado Y Mantenimiento

SP

Limpieza exterior del AquaNano Use un trapo limpio húmedo y jabón neutro no abrasivo para limpiar la parte exterior del filtro. Use un trapo limpio húmedo y jabón neutro no abrasivo para limpiar la parte exterior del grifo, los cartuchos del filtro y la base de la unidad. No use jabón lavaplatos. Pásele un trapo. Usar pulituras, detergentes, sustancias abrasivas, limpiadores, solventes orgánicos o ácido puede dañar la unidad. USAR IMPLEMENTOS DISTINTOS A UN TRAPO LIMPIO HÚMEDO Y JABÓN NEUTRO ANULARÁ LA GARANTÍA. NOTA: No sumerja la unidad CTU o UCU en agua ni la deje en remojo. El exceso de humedad en el interior de la unidad la dañará y anulará la garantía.

Medidor de flujo no funciona Si el medidor de flujo electrónico no funciona, reinícielo con uno de los siguientes procedimientos:

Luces indicadoras de reemplazo

1. Retire la tapa del compartimiento de las baterías que se encuentra en la parte inferior de la base, desatornillando los dos tornillos y levantando la tapa con cuidado con la ayuda de un destornillador punta plana en el lugar indicado en el dibujo. 2. Retire las baterías usadas, espere 20 segundos, y reemplácelas por dos baterías AA nuevas de buena calidad. 3. Reemplace el cartucho del filtro NanoCeram®. 4. La unidad volverá a tener la configuración de fábrica.

UCU-200 CAL

CTU-200 CAL

Su AquaNano incluye un medidor de flujo en la base de la unidad. Cuando el agua fluye por el filtro, luces LED (diodo emisor de luz) titilarán para indicar: •

F I LT E R I N G ( F I LT R A R ) : La luz azul indica que la unidad funciona

correctamente. •

R E O R D E R ( O R D E N A R ) : La luz amarilla indica que le quedan

aproximadamente 1,893 litros (500 galones) de vida útil al cartucho NanoCeram®. Comuníquese con su Asesor Rena Ware o con el Centro de Servicio Rena Ware para ordenar repuestos. La luz azul F I LT E R I N G también indica que su filtro sigue funcionando •

R E P L AC E ( R E E M P L A Z A R ) : La luz roja indica que la vida útil del

cartucho NanoCeram® ha expirado. La luz azul F I LT E R I N G no se encenderá. Reemplace el cartucho NanoCeram® antes de volver a usar su filtro. 58

59

5. Voltee el cartucho del prefiltro y coloque el adaptador de flujo de retorno sobre la boquilla de salida del prefiltro.



Lavado con flujo invertido a presión, limpieza y reemplazo del prefiltro EM y del cartucho NanoCeram® Para mantener adecuadamente el prefiltro, se debe lavar con flujo invertido a presión y limpiar regularmente (hasta tres veces) siempre que haya una reducción de flujo significativa. El elemento desechable EM se debe reemplazar cuando estos procedimientos no restauran un flujo aceptable. NOTA: Se necesitan dos personas para realizar este procedimiento. Nunca lave el cartucho NanoCeram® con flujo invertido a presión. Si lo hace, dañará y contaminará su estructura interna haciendo que el filtro pierda su efectividad. Si lo daña, dejará de filtrar agua.

1. Asegúrese de que la llave del agua esté cerrada.

6. Inserte la boquilla de salida de la caja de entrada en el otro extremo del adaptador de flujo de retorno y ejerza presión sobre el mismo. Sostenga el prefiltro invertido sobre el fregadero, u otro contenedor de al menos 2 galones (7.5 litros) de capacidad.



 2. Retire el adaptador de flujo invertido de la caja de entrada.

7. Pida a la otra persona que abra la llave de agua. Cuando la abra, habrá un poco de contrapresión que tratará de sacar la caja de entrada del adaptador de flujo de retorno, por lo que deberá mantener juntas la caja de entrada, el adaptador de flujo de retorno y el prefiltro ejerciendo presión sobre ellos para evitar que se separen. 3. Retire la caja de entrada girándola en sentido contrario a las manecillas del reloj hasta que se afloje.

8. Deje correr agua por cinco minutos, sacuda el cartucho y dele golpecitos contra el fregadero hasta que el caudal haya aumentado. 9. Abra el alojamiento girándolo en sentido contrario a las manecillas del reloj.

4. Retire el cartucho del prefiltro del cartucho NanoCeram® girándolo en sentido contrario a las manecillas del reloj hasta que se afloje.

60

61

SP

10. Para retirar el elemento desechable del alojamiento, sujete la base de este con las dos manos y empuje la parte superior del elemento desechable hacia arriba con los dos pulgares. Luego de sacarlo, deséchelo o lávelo.

Vuelva a conectar temporalmente la caja de entrada a la base del filtro. Lave el alojamiento reusable y enjuague el elemento desechable con agua y seque. Cuando lave el elemento desechable puede frotarlo un poco. Si la parte externa del elemento desechable se frota muy duro, se podrá dañar permanentemente. NO USE JABÓN

11. Inserte el elemento desechable con la boquilla de salida hacia abajo y la parte plana hacia arriba.

12. Cierre el alojamiento girando la parte superior en sentido contrario a las manecillas del reloj hasta que las flechas que aparecen en él estén prácticamente alineadas, y reinstálelo.

NOTA: El Prefiltro y el NanoCeram® no se reemplazan necesariamente al mismo tiempo, y las luces led solo indicarán el estado del Cartucho NanoCeram®, por lo tanto, reemplácelo cuando titile la luz roja de advertencia del medidor de flujo. También deberá reemplazar las baterías.

13. Repita el paso 3. Para cambiar el cartucho NanoCeram®, sáquelo girándolo en sentido contrario a las manecillas del reloj hasta que se afloje y deséchelo.

14. Retire la tapa del compartimiento de baterías que está en la parte inferior de la base, desatornillando los dos tornillos y levantando la tapa con cuidado con un destornillador punta plana.

15. Retire las baterías, espere 20 segundos, y luego instale dos baterías AA nuevas de buena calidad. Esto reinicializará el medidor de flujo en “0” y las luces LED titilarán nuevamente cuando se haga correr agua por el filtro. 16. Saque el nuevo cartucho NanoCeram® de su empaque, instálelo y cárguelo como se indica en la sección “INSTALACIÓN”.

NOTA: El lavado con flujo invertido a presión y el enjuague mejorarán el flujo pero no harán que el cartucho del prefiltro quede “como nuevo”. Esto funcionará cada vez menos, hasta que sea necesario reemplazar el cartucho del prefiltro para restaurar el flujo a un nivel aceptable. 62

17. Deje correr agua fría por dos minutos para eliminar partículas de carbón y aire atrapado.

63

SP

Resolución De Problemas 1. No sale agua por el cabezal aspersor del UCU-200… • Asegúrese de que las llaves de agua estén abiertas.

Repuestos

SP

NOTE: Use siempre repuestos originales Rena Ware.

• Gire la válvula de desviación a la posición “abierta” adecuada.

Comuníquese con su Representante Rena Ware o con el Centro de Servicio al Cliente Rena Ware más cercano para ordenar repuestos para el filtro de agua AquaNano. También puede visitar el sitio web de Rena Ware en www. renaware.com para obtener más información sobre nuestros Centros de Servicio y productos.

• Saque la válvula de desviación y asegúrese de que el reductor de flujo se encuentre en la posición correcta y no esté bloqueado por algún residuo.

Cartucho NanoCeram®

• Asegúrese de que el tubo esté holgado y recto, sin hendiduras.

Alojamiento del prefiltro

• Asegúrese de que los tubos estén holgados y rectos, sin hendiduras. 2. No sale agua por la varilla del CTU-200…

3. Sale agua entre los cartuchos del filtro, o en la caja de entrada del filtro o en la base del filtro… • Separe los cartuchos donde exista la fuga de agua. Cada cartucho y la entrada del filtro deberían tener dos juntas tóricas en el orificio de salida elevado que se encuentra entre las tres patas. Compruebe que las juntas tóricas estén en su lugar y bien colocadas en las ranuras correspondientes.

Válvula de desviación Elemento desechable EM

4. Hay fuga de agua en el tubo… • Para el modelo CTU-200: Si hay fuga de agua en la válvula de desviación, desenrosque el cuello en la entrada de la válvula y empuje el tubo firmemente sobre la punta de la válvula de desviación. Asegúrese de que el tubo de entrada esté conectado a la punta de la válvula de desviación. Deslice el cuello a su posición por el tubo hasta la entrada de la válvula de desviación y enrósquelo firmemente en su lugar. • Para el CTU y el UCU-200: Verifique que el tubo no esté roto ni tenga hendiduras. 5. Verifique que el tubo no esté roto ni tenga hendiduras… • Puede seguir saliendo agua por el cabezal aspersor por corto tiempo debido a la presión contenida en el filtro, pero dejará de salir. • El aire atrapado en el filtro puede hacer que salga agua después de haber cerrado la llave de agua. Para eliminar el aire retenido, llene los cartuchos con agua hasta que vea salir agua a través del orificio superior de los cartuchos. Esto se conoce como “cargar” el cartucho y se hace manualmente sin la caja en la parte superior del cartucho del filtro. Consulte la sección “Carga del sistema”. 6. Las luces en el cuello del grifo o en la base no funcionan… • Asegúrese de que el cable de datos esté bien conectado al puerto de datos.

Especificaciones AquaNano Presión operativa máxima

690 kPa (100 psi)

Presión operativa mínima

207 kPa (30 psi)

Temperatura máxima del agua

38°C (100°F)

Temperatura mínima del agua

4°C (40°F)

Caudal del agua filtrada a 60 psi

5.68 LPM (1.5 GPM)

Capacidad del cartucho NanoCeram®

11,355 L (3,000 GAL) o un año



• Revise las baterías.

64

65

GARANTÍA

NOTES / NOTAS

La Garantía Limitada de AquaNano Rena Ware garantiza que sus sistemas de filtración de agua AquaNano están libres de defectos de materiales y de fabricación durante un año contado a partir de la fecha de compra. Este Producto se debe usar en los hogares con agua tratada por el municipio solamente. Esta Garantía no cubre daños que resulten del uso del producto con agua que tenga mucha interferencia química, materiales suspendidos o partículas sólidas visibles. Esta Garantía no cubre el desgaste normal de las conexiones de válvulas, juntas tóricas, piezas de caucho o plástico ni cartuchos del filtro. Esta Garantía no cubre los defectos que resulten del uso inadecuado, abuso, negligencia, accidentes, uso del Producto de un modo diferente al que se describe en las instrucciones y en la etiqueta de las especificaciones, reparaciones o alteraciones efectuadas fuera de los locales de Rena Ware, o por falta de mantenimiento. El usar piezas de reemplazo que no sean piezas de reemplazo verdaderas de Rena Ware o quitar la etiqueta de las especificaciones cancelará esta Garantía. Esta Garantía no cubre los daños incidentales o consecuentes que resulten del uso de este Producto.

Alcance de la Garantía Según lo estime conveniente, Rena Ware reparará o reemplazará el Producto, o cualquier parte del mismo, que haya sido determinado como defectuoso. Si se efectúa el reemplazo, el Producto por el que se hizo el reemplazo pasará a ser propiedad de Rena Ware. Este recurso será el único disponible.

Modo de efectuar la Garantía Para obtener servicio bajo la Garantía debe enviar una descripción detallada, por escrito, del defecto alegado al Centro de Servicio de Rena Ware más cercano. Tal vez se le solicite que devuelva el Producto, por su cuenta, al Centro de Servicio de Rena Ware más cercano a su localidad con el objeto de brindarle el servicio bajo la garantía. Tal vez se le solicite también que proporcione una constancia de su compra. Si después de la inspección, Rena Ware determina que existe un defecto cubierto por la Garantía, Rena Ware asumirá el costo de la devolución del producto.

Otras limitaciones de la Garantía Esta Garantía se ofrece en lugar de toda otra garantía explícita. Cualquier garantía implícita tendrá el mismo período de duración que la Garantía explícita indicada arriba. Algunas jurisdicciones no permiten la exclusión o limitación de daños incidentales o consecuentes o no permiten limitaciones en la duración de una garantía implícita, por lo que las limitaciones o exclusiones citadas arriba pueden no concernirle a usted. Esta Garantía le otorga derechos legales específicos. Usted también podrá tener otros derechos que varían de una jurisdicción a otra. Esta Garantía se aplica solamente a los sistemas de filtración de agua AquaNano. Otras garantías se aplican a los utensilios de cocina u otros productos de Rena Ware.

66

Rena Ware International offers many other great values, like our fabulous ‘‘water-less’’ cookware. Ask your Rena Ware Independent Representative for more information on our full product line. Join Our Team If you love your Rena Ware AquaNano water filter and other Rena Ware products, you may want to join our team. It’s easy, fun, exciting, and profitable. Contact your Independent Representative for more information on starting your own Rena Ware business!

Rena Ware International ofrece muchos otros beneficios, como nuestros fabulosos utensilios de cocina para cocinar con un mínimo de agua. Pídale más información sobre nuestra línea de productos a su Representante Independiente Rena Ware. Únase a nuestro equipo Si a usted le encanta su AquaNano de Rena Ware al igual que otros productos Rena Ware, tal vez quiera unirse a nuestro equipo. Es fácil, divertido, emocionante y lucrativo. ¡Comuníquese con su Representante Independiente para recibir más información sobre cómo comenzar su propio negocio Rena Ware!

www.renaware.com AQ 650 California 2650.08.0214

Home Office U.S.A. (425) 881.6171 | Copyright © 2014 R.W.I.

facebook.com/RenaWare