OIL BURNERS
h
f
MAX 4 AB MAX 8 AB MAX 12 AB HYDRAULIC SYSTEM
420010346202 16.03.2011
420010346202 Max 4 - 8 - 12 AB HS
TECHNICAL DATA MODELS
MAX 4 AB
Thermal power max.
kcal/h kW kcal/h kW kg/h kg/h 50 Hz V W Nº kV/mA LANDIS kcal/kg
Thermal power min. Max. flow rate light oil Min. flow rate light oil Feeding power Motor Rpm Ignition transformer Control box Fuel: light oil
51.000 59 17.340 20 5 1,7 230 75 2.800 2x12 LOA 24
MAX 8 AB
MAX 12 AB
90.780 112.200 105 130 40.800 52.000 47 60 8,9 11 4 5,1 230 230 100 130 2.800 2.800 2x12 2x12 LOA 24 LOA 24 10.200 max. visc 1,5°E a 20°C
WORKING FIELDS PRESSURE IN THE COMBUSTION CHAMBER
4
3
2
1
0 10
20 20
1
30 30
2
40 40
3
50 50
60
60
4
70
70
5
80
6
80 90
7
90 100
100 110
8
120
9
110 130
10
11
120 140 12
BURNER OUTPUT
OVERALL DIMENSIONS A D-D1
C
E
151 126
L
F
B
G
M
MODELS MAX 4 AB HS MAX 8 AB HS MAX 12 AB HS
A
B
C
D
D1
E
F
G
288 294 308
149 155 169
139 139 139
90 90 100
145 145 155
204 204 204
89 89 98
160 160 160
D = short head D1 = long head pag.2
I
I
L
90/107 90/107 100/120 100/120 100/120 100/120
M M8 M8 M8
420010346202 Max 4 - 8 - 12 AB HS
MAXIMUM LENGTHS OF SUCTION LINES FOR TWO-PIPE SYSTEM SUNTEC Two-pipe siphon feed system H H (m) (m)
0,5 1 1,5 2 2,5 3 3,5
y
H
Length pipe (m) ø 8 mm
ø 10 mm
30 35 40 45 50 55 60
65 70 75 80 85 90 95
Two-pipe lift system H H (m) (m)
0,5 1 1,5 2 2,5 3 3,5
H
Length pipe (m) ø 8 mm
ø 10 mm
23 21 19 17 14 9 4
55 50 45 40 34 28 22
ADJUSTMENT DATA NOZZLE gph spry
PUMP bar
OUTPUT kg/h
FIRING HEAD SETTING AIR DAMPER ADJUSTMENT Pos. Pos.
NOZZLE : DANFOSS H÷S 80°÷60°; DELAVAN W 60°; STEINEN S 60°
pag.3
420010346202 Max 4 - 8 - 12 AB HS
PRIMING AND ADJUSTMENT OF OIL PUMP SUNTEC AT3V 45A
8
4 6
7 V
P
SUNTEC
3
1 2 3 4 5 6 7 8
-
INLET RETURN BLEED AND PRESSURE GAUGE PORT VACUUM GAUGE PORT PRESSURE ADJUSTMENT TO NOZZLE PRESSURE ADJUSTMENT SPECIAL PRESSURE PORT
5 1
2
VERIFY: - That piping system is perfectly sealed. - That the use of hoses is avoided whenever is possible (use copper pipes preferably). - That depression is not greater than 0,45 bar, to avoid pump’s cavitation. - That check valve is suitably designed for the duty. The pump pressure is set at a value of 12 bar during the testing of burners. Before starting the burner, bleed the air in the pump through the gauge port. Fill the piping with light-oil to facilitate the pump priming. Start the burner and check the pump feeding pressure. In case the pump priming does not take place during the first prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner’s lock-out to restart, by pushing the button on the control box. If, after a successful pump priming, the burner locks-out after the prepurging, due to a fuel pressure drop in the pump, rearm the burner’s lock-out to restart the burner. Do never allow the pump working without oil for more than three minutes. Note: before starting the burner, check that the return pipe is open. An eventual obstruction could damage the pump sealing device. 1 - HOSE 2 - OIL FILTER 3 - OIL COCK
1 2
1
3
NOZZLE CLEANING AND REPLACEMENT Use only the suitable box wrench provided for this operation to remove the nozzle, taking care to not damage the electrodes. Fit the new nozzle by the same care. Note: Always check the position of electrodes after having replaced the nozzle (see illustration). A wrong position could cause ignition troubles. 4 mm
3 mm
5/6 mm
pag.4
420010346202 Max 4 - 8 - 12 AB HS
BURNER START-UP AND ADJUSMENT Once having installed the burner, check the following items: - The burner power feeding and the main line protection fuses - The correct length of pipes and that sames are sealed. - The type of fuel, which must be suitable for burner. - The connection of boiler’s thermostats and all safeties. - The motor direction of rotation. - The correct calibration of the motor’s thermal protection. When all said conditions are checked and accomplished, it is possible to go on with burner’s tests. Power the burner. The control box feeds at the same time the ignition transformer and the burner’s motor, which will run a prepurging of the combustion chamber for about 12 seconds. At the end of prepurging, the control box opens the fuel pump solenoid valve, the ignition transformer produces a spark and the burner ignites. After a safety interval of 5 seconds and a correct ignition, the control box turns off the ignition transformer. In case of faulty ignition, the control box switches the burner into safety condition within 10 secs. In such a case, the manual rearming of the burner shall not take place before 30 seconds are elapsed from the burner’s safety shutdown. The fuel pump feeding pressure, must keep around 12 bar. Note: With preheated version, the burner runs a preheating of the combustion head for about 1 minute. In such a case, at the boiler’s thermostats make, the ignition signal shall be done by the thermostat mounted on the preheater itself. FIRING HEAD SETTING
AIR REGULATION
0
1
2
2°nd stage
+
-
+ 1°st stage
pag.5
420010346202 Max 4 - 8 - 12 AB HS
MOUNTING TO THE BOILER
+ 3
–
2 1
TUBE DISASSEMBLY
+
–
pag.6
pag.7
COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE.
A TERMINE DI LEGGE E' VIETATO RIPRODURRE O
PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A.
E
D
C
B
SOST.DA
SOST.IL
IND.MOD.
00
DATA-FIRMA
01
FIRMA
01
1
M
CONTROLLATO
DISEGNATO
DESCRIZIONE MODIFICA
MV
02
02
DATA
03
04
T7
T7
P
T6
T6
05-02-2007
T
STAB
T8
T8
HL2
B5
B5
03
HL1
B4
B4
S3
S3
HLB
T1
T1
N
N
T
STS
T
STC
L1
L1
P
P
B
04
UFF.TECNICO-SETTORE ELETTRICO
T2
T2
YVg1
S.p.A.
05
LANDIS LOA 24 06
07
B 08
BEM21179
SISTEMA IDRAULICO CODICE
SIST. RIVELAZ.
09
ELETTROVALVOLA GASOLIO DI SECONDA FIAMMA SECOND STAGE OIL SOLENOID VALVE ELECTROVANNE MAZOUT GRANDE ALLURE ELECTROVALVULA DE GASOLEO 2^ LLAMA
TERMOSTATO DI ALTA-BASSA FIAMMA HIGH-LOW FLAME THERMOSTAT THERMOSTAT GRANDE-PETIRE ALLURE TERMOSTATO DE ALTA-BAJA LLAMA
STAB
YVg2
TERMOSTATO DI SICUREZZA SAFETY THERMOSTAT THERMOSTAT DE SECURITE TERMOSTATO DE SEGURIDAD
STS
ELETTROVALVOLA GASOLIO DI PRIMA FIAMMA FIRST STAGE OIL SOLENOID VALVE ELECTROVANNE MAZOUT PETITE ALLURE ELECTROVALVULA DE GASOLEO 1^ LLAMA
TERMOSTATO CALDAIA BOILER THERMOSTAT THERMOSTAT CHAUDIERE TERMOSTATO CALDERA
STC
09
YVg1
LAMPADA DI BLOCCO LOCK-OUT LAMP LAMPE DE SECURITE ESPIA DE BLOQUEO
LAMPADA DI PRIMA FIAMMA 1.ST FLAME LAMP LAMPE DE 1^ ALLURE ESPIA DE 1^ LLAMA
HL1
HLB
TRASFORMATORE IGNITION TRANSFORMER TRANSFORMATEUR D'ALLUMAGE TRANSFORMADOR
TV
LAMPADA DI SECONDA FIAMMA 2.ST FLAME LAMP LAMPE DE 2^ ALLURE ESPIA DE 2^ LLAMA
MOTORE VENTILATORE MOTOR FAN MUTEUR VENTILATEUR MOTOR VENTILADOR
MV
HL2
INTERRUTTORE GENERALE CON FUSIBILE MAIN SWITCH WITH FUSE INTERRUPTEUR GENERAL AVEC FUSIBLE INTERRUPTOR GENERAL CON FUSIBLE
Q
08
FOTORESISTENZA PHOTO-RESISTOR PHOTORESISTANCE FOTORESISTENCIA
B
APPARECCHIATURA
CONTROLLO DI TENUTA
07
MOTORIDUTTORE
N
L
PE
TV
06
MINOR 12 AB / MAX 4-8-12
05
DENOMINAZIONE
Q
50 Hz 230 V
YVg2
LANDIS LOA 24 1 2 3 4 5 6 7 8 9 10 11 12 31 32
FIRMA
A
00
IND.MODIFICA
E
D
C
B
A
420010346202 Max 4 - 8 - 12 AB HS
DATA
7
27
pag.8
6
5
1
3
2
15
16
25 26
22
28
4
9
29
30
10
23
12 13 11
24
21
27
33
19
32 25
37 38 37
34
33
26 22 28
38
MAX 8-12
24
MAX 4 AB HS - MAX 8 AB HS - MAX 12 AB HS
17 14
18
MAX 8 MAX 12
36
39
20
35
420010346202 Max 4 - 8 - 12 AB HS
420010346202 Max 4 - 8 - 12 AB HS
N° 1
DESCRIPTION OIL PUMP
2
COIL
SUNTEC
3
OIL VALVE
SUNTEC
4
COUPLING
5
NIPPLE
TN 6 X 700
6
HOSES
NW 6X700
7
FILTER
ART.70451-006AV
8
COVER
9
MOTOR
MAX 4 AB HS
MAX 8 AB HS
code
code
code
65325120 65323767 65323744 65322920 65321179 65323189 65325046
65325120 65323767 65323744 65322920 65321179 65323189 65325046
65325120 65323767 65323744 65322920 65321179 65323189 65325046
65322867 -
65322874
65321857 65325038 65324966 65320092 65320028 65320076 65322076 65320663 65321770
-
65322873 65321857
65321061 65324964 65320933 65320934 65320924 65320325 65320326 65322554 65322555 65320687 65320707 65320747 65320181 65320182 65320968 65321104
65321848 65325000 65324966 65320092 65320028 65320076 65322076 65320663 65321770 65320621 65321061 65324964 65320933 65320934 65320924 65320298 65320299 65322556 65322557 65320687 65320707 65320751 65320183 65320184 65320972 65321109
65325000 65324966 65320092 65320028 65320076 65322076 65320663 65321770 65320621 65321061 65324964 65320933 65320934 65320924 65320362 65320363 65322558 65322559 65320687 65320707 65320753 65320187 65320188 65320972 65321109
65321065 65321500 65322331 65321510 65322069 65322065 65322070 65322068 65325965
65320723 65321065 65321500 65322331 65321510 65322069 65322065 65322070 65322068 65325965
65320726 65321065 65321500 65322331 65321510 65322069 65322065 65322070 65322068 65320538
SUNTEC AT3V 45A
75 W 100 W
MAX 12 AB HS
130 W AEG 10
CAPACITOR
3 µF AEG 5 µF SIMEL 4 µF AEG 6,3 µF SIMEL
11
IGNITION TRANSFORMER
12
CONTROL BOX BASE
13
CONTROL BOX
14
PHOTORESISTOR
15
WIRING TERMINAL BOX
16
PROTECTION BOX
17
FAN
18
FAN SCOOP
19
ORING
20
COVER AIR INLET
21
CABLES
FIDA MOD.26/30 LANDIS LANDIS LOA24 LANDIS
120 x 50
TC TL
22
ELECTRODES
23
BLAST TUBE
TC TL
24
FIRING HEAD
TC
25
NOZZLE HOLDER SUPPORT
26
NOZZLE HOLDER
27
DIFFUSER
28
ROD
29
FLANGE
30
GASKET
31
ANTIJAMMING FILTER
32
REAR DISC
33
PIPE GASKET
34
PIPE
35
HYDRAULIC SYSTEM
TL
TC TL
36
PIPE HYDRAULIC SYSTEM
37
PLUG WIELAND
38
SOCKET WIELAND
7 pin 4 pin 7 pin 4 pin
39
AIR DAMPER
TC = SHORT HEAD
TL = LONG HEAD pag.9
R =VERSION PRE-HEATER
420010346202 Max 4 - 8 - 12 AB HS
FAULT FINDING Burner does not start up
-
Mains switch not on. Blown fuse. Boiler thermostats not made. Fault in control box.
Burner pre-purges and stops
-
Fault in control box.
Burner does not ignite during cycle and stops
-
Fault in control box. Fault in photo-resistor.
Burner does not ignite
-
Dirty ignition electrodes. Fault at electrodes. Electrodes installed wrongly. Faulty ignition transformer. Blocked nozzle. Nozzle needs replacing. Oil pressure too low. Blocked oil filter. Excessive combustion air for nozzle capacity. Fault in control box.
Burner ignites and then stops
-
Faulty nozzle. Photo-resistor does not "see" flame. Excessive combustion air for nozzle capacity. Fault in control box. Oil pressure too low. Blocked oil filter.
No high flame at burner (2nd stage)
-
2nd stage valve coil faulty. Oil pressure too low Dirty filter Fault in control box.
pag.10
420010346202 Max 4 - 8 - 12 AB HS
pag.11
ECOFLAM BRUCIATORI S.p.A. reserves the right to make any adjustments, without prior notice, which it considers necessary or useful to its products, without affecting their main features.
Ecoflam (UK) Limited 12 Goodwood Road , Keytec 7 Business Park, Wyre Road, Pershore, Worcestershire, WR10 2JL England Tel: 01386 556092 - Fax: 01386 553789
Ecoflam Bruciatori S.p.A. via Roma, 64 - 31023 RESANA (TV) - Italy - tel. 0423.719500 - fax 0423.719580 http://www.ecoflam-burners.com - e-mail:
[email protected] "società soggetta alla direzione e al coordinamento della Ariston Thermo S.p.A., via A. Merloni, 45 - 60044 Fabriano (An) CF 01026940427"