CITY OF VANCOUVER
PHONE: 360.694.2691 www.maulfoster.com
MAUL
PREPARED FOR:
400 EAST MILL PLAIN BLVD, SUITE 400 VANCOUVER, WAS 98660
ALONGI FOSTER
LOWER GRAND INDUSTRIAL AREA LOCATED IN SEC. 26, T. 2 N., R. 1 E., W.M., CLARK COUNTY, VANCOUVER, WASHINGTON
PROJECT CONTACTS
PLOTTED ON: 2015-10-13 8:29 PM
PLOTTED BY: Lindsey Crosby
STREET AND STORMWATER PLAN AND PROFILE E1ST ST STA 99+75 TO STA 104+00
C3.7
STREET AND STORMWATER PLAN AND PROFILE E1ST ST STA 104+00 TO STA 108+00
C3.8
STREET AND STORMWATER PLAN AND PROFILE E1ST ST STA 108+00 TO STA 112+00
C3.9
STREET AND STORMWATER PLAN AND PROFILE E1ST ST STA 112+00 TO STA 115+52.98
C4.0
STREET CROSS SECTION DETAILS
C4.1
STORMWATER DETAILS
C4.2
CITY OF VANCOUVER TRANSPORTATION DETAILS I
C4.3
CITY OF VANCOUVER TRANSPORTATION DETAILS II
DESCRIPTION
C3.6
1.
SURVEY PERFORMED BY OTAK IN JULY 2014. 7.
2.
3.
4.
5.
6.
HORIZONTAL DATUM: WASHINGTON STATE PLANE COORDINATE SYSTEM SOUTH ZONE. ELEVATION DATUM: NGVD29 BASED ON CITY OF VANCOUVER BENCH MARK 109-96. ELEV. = 28.22 CONTRACTOR TO VERIFY ALL UTILITY LOCATIONS AND DEPTHS PRIOR TO CONSTRUCTION. A MINIMUM OF TWO FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL CALL 811 (UTILITY NOTIFICATION CENTER) FOR LOCATION MARK-UP OF EXISTING UTILITIES. ALL CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE LATEST STANDARDS AND PRACTICES OF THE CITY OF VANCOUVER AND THE LATEST EDITION OF THE "STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION" PREPARED BY WSDOT/APWA. IN CASE OF A CONFLICT BETWEEN THE REGULATORY STANDARDS OR SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT WILL PREVAIL. ANY CHANGES TO THE DESIGN AND/OR CONSTRUCTION SHALL BE APPROVED BY THE OWNER OR ENGINEER.
APPROVAL OF THESE PLANS DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION NOT SPECIFICALLY SHOWN ON THE PLANS. PLANS FOR STRUCTURES SUCH AS BRIDGES, BUILDINGS, TANKS, VAULTS, ROCKERIES, AND RETAINING WALLS MAY REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE BUILDING DEPARTMENT PRIOR TO CONSTRUCTION.
8.
A COPY OF THESE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS AND PERMITS NECESSARY TO PERFORM THE WORK.
12. ALL CONSTRUCTION WITHIN THE PUBLIC RIGHT-OF-WAY SHALL HAVE AN APPROVED PUBLIC RIGHT-OF-WAY WORK PERMIT PRIOR TO ANY CONSTRUCTION ACTIVITY WITHIN THE RIGHT-OF-WAY. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST ADOPTED EDITION OF THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD) PUBLISHED BY THE U.S. DEPARTMENT OF TRANSPORTATION. TWO-WAY TRAFFIC MUST BE MAINTAINED AT ALL TIMES ON THE ADJACENT PUBLIC STREETS.
GAS, IRRIGATION, AND STREET LIGHTING. THE CONTRACTOR SHALL NOTIFY RESIDENTS AND BUSINESSES 48 HOURS IN ADVANCE OF ANY WORK AFFECTING ACCESS OR SERVICE AND SHALL MINIMIZE INTERRUPTIONS TO DRIVEWAYS FOR RESIDENTS AND BUSINESSES ADJACENT TO THE PROJECT.
####
#### ####
GENERAL NOTES
PROJECT:
DATE
STREET AND STORMWATER PLAN AND PROFILE Y ST STA 22+50 TO STA 26+57.39
ISSUE
C3.5
VANCOUVER, WASHINGTON
STREET AND STORMWATER PLAN AND PROFILE E2ND ST STA 19+50 TO STA 22+50
0363.08.01
DESIGNED: C. GOKCORA
16. ALL LAWN AND VEGETATED AREAS DISTURBED WILL BE RESTORED TO ORIGINAL CONDITION. ANY DISTURBANCE OR DAMAGE TO OTHER PROPERTY ON ADJACENT PARCELS OR IN THE PUBLIC RIGHT OF WAY SHALL ALSO BE REPAIRED OR RESTORED TO ORIGINAL CONDITION.
DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE
DRAWING NOT TO SCALE
SHEET TITLE
10. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION STAKING. 11. PUBLIC AND PRIVATE DRAINAGE WAYS SHALL BE PROTECTED FROM POLLUTION. NO MATERIAL IS TO BE DISCHARGED TO OR DEPOSITED IN STORMWATER SYSTEMS THAT MAY RESULT IN VIOLATION OF STATE OR FEDERAL WATER QUALITY STANDARDS.
----
C3.4
----
STREET AND STORMWATER PLAN AND PROFILE E2ND ST STA 15+00 TO STA 19+50
----
C3.3
----
STREET AND STORMWATER PLAN AND PROFILE E2ND ST STA 11+00 TO STA 15+00
----
C3.2
10/14/15
----
STREET AND STORMWATER PLAN AND PROFILE V ST STA 8+59 TO STA 11+00
####
C3.1
####
MASTER STREET AND STORMWATER PLAN
####
C3.0
30% DESIGN
EXISTING CONDITIONS
####
NOT TO SCALE
C1.2
####
VICINITY MAP
MASTER LEGEND
####
NEW IMPROVEMENTS: THIS PROJECT IMPROVES THE LOWER GRAND INDUSTRIAL AREA, INCLUDING PERVIOUS PAVING OF THE STREETS, THE ADDITION OF PERVIOUS CONCRETE SIDEWALKS, THE INSTALLATION OF BIORETENTION FACILITIES, THE INSTALLATION OF AN OVERFLOW STORM SYSTEM AND AN ASPHALT REPAIR OF E 1ST STREET.
C1.1
####
FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\0.0 Cover.dwg
SITE ADDRESS: LOWER GRAND INDUSTRIAL AREA, ENCOMPASSED BY E 1ST ST, E 2ND ST, V ST AND Y ST
COVER SHEET
####
PROJECT SUMMARY
C0.0
####
AGENCY CITY OF VANCOUVER 415 W. 6TH ST VANCOUVER, WA 98660 P: 360-487-7190 ANNETTE GRIFFY, PE
SHEET INDEX
####
SURVEYOR OTAK 700 WASHINGTON STREET SUITE #401 VANCOUVER, WA 98660 P: 360-737-9613
SITE
####
MAUL, FOSTER & ALONGI, INC. 400 E. MILL PLAIN BLVD SUITE #400 VANCOUVER, WA 98660 P: 360-694-2691 STACY FROST, PE
[email protected]
####
CIVIL ENGINEER
CITY OF VANCOUVER 415 W. 6TH ST VANCOUVER, WA 98660 P: 360-487-7190 ANNETTE GRIFFY, PE
LOWER GRAND INDUSTRIAL AREA
CLIENT
14. ANY PUBLIC OR PRIVATE CURB, GUTTER, SIDEWALK, OR ASPHALT DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO CITY OF VANCOUVER STANDARDS AND PRACTICES.
COVER
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF ADJACENT UTILITIES WHICH MAY INCLUDE, BUT ARE NOT LIMITED TO, WATER, SANITARY SEWER, STORMWATER, POWER, TELEPHONE, CABLE TV,
SHEET
NOT FOR CONSTRUCTION
C0.0
PLOTTED ON: 2015-10-13 7:49 PM
PLOTTED BY: Lindsey Crosby
GALLON(-S) GAS METER GROUND GUARD POST GALLONS PER MINUTE GRADE GAS VALVE, GATE VALVE
HDPE HGT, HT HP HORZ HYD
HIGH DENSITY POLYETHYLENE HEIGHT HORSEPOWER HORIZONTAL HYDRANT
ID IE IN IP INTX INV
INSIDE DIAMETER INVERT ELEVATION INCH(-ES) IRON PIPE INTERSECTION INVERT
S SSWR SB SCH SD SDR SE SF SHT SL SPEC SQ SQ IN SRF ST STA STD STL STRM STRUCT SW,S/W
SOUTH, SLOPE SANITARY SOIL BORING SCHEDULE STORM DRAIN STANDARD DIMENSION RATIO SOUTHEAST SQUARE FEET SHEET SLOPE SPECIFICATIONS SQUARE SQUARE INCHES SURFACE STREET STATION STANDARD STEEL STORM STRUCTUR(-E, -AL) SIDEWALK, SOUTHWEST
TB TBM TC TEL, TELE TEMP TW TP TYP
THRUST BLOCK TEMPORARY BENCHMARK TOP OF CURB TELEPHONE TEMPORARY TOP OF WALL TOP OF PAVEMENT, TEL POLE, TURNING POINT TYPICAL
UG UGE
UNDERGROUND UNDERGROUND ELECTRIC
VC VERT VOL
VERTICAL CURVE VERTICAL VOLUME
W W/ WC WM W/O WSE WTR WV
WIDTH; WIDE; WEST WITH WITNESS CORNER WATER METER WITHOUT WATER SURFACE ELEVATION WATER GATE/GENERAL WATER VALVE
ALONGI REDUCER THRUST BLOCK
POWER VAULT
WATER METER TRANSMISSION TOWER
DOUBLE CHECK VALVE ASSEMBLY
UTILITY POLE
AIR RELIEF
LENGTH LATERAL
YD YR
YARD YEAR
STOP
FIRE HYDRANT RAISED MARKERS: LANE MARKERS TYPE I BLOW-OFF VALVE
UTILITY POLE ANCHOR
CHECK VALVE
LANE MARKERS TYPE II
GATE VALVE
TELEPHONE RISER
SIGN
TELEPHONE VAULT
BENDS:
LIGHT POLE
90 DEGREE BEND 45 DEGREE BEND
MISCELLANEOUS SYMBOLS
22.5 DEGREE BEND
SURVEY SYMBOLS
11.25 DEGREE BEND
SYMBOL DESCRIPTION THEOR./ FOUND/ EXIST. PROP.
SYMBOL EXIST. PROP.
VERTICAL BEND TEE
DESCRIPTION MONITORING WELL
CROSS
ANGLE POINT
INLET PROTECTION PILLOW
BENCH MARK
10/14/15
CONSTRUCTION ENTRANCE
BLOCK CORNER IRON PIPE
PROPOSED SPOT SHOT
SANITARY/STORM SEWER SYMBOLS
MONUMENT OWNERSHIP TIE
SYMBOL EXIST. PROP.
SECTION DATA: SECTION CENTER
DESCRIPTION
SAN. SEWER CLEAN OUT
SECTION CORNER S
S
QUARTER CORNER
SECTION NUMBER
SAN. SEWER MANHOLE
A C1.X
STORM DRAIN CATCH BASIN
CB
SIXTEENTH CORNER
MEANDER CORNER D
D
STORM DRAIN MANHOLE
DETAIL NUMBER X C1.X
SECTION REFERENCE SHEET
STORM DRAIN CULVERT
CLOSING CORNER
TYPICAL SECTION CALLOUT
DETAIL REFERENCE SHEET TYPICAL DETAIL CALLOUT
WITNESS CORNER DRY WELL
SOIL BORING SPOT ELEVATION
AREA DRAIN
EXISTING GRADE MAJOR CONTOUR
27
PROPOSED GRADE MAJOR CONTOUR (1.0' INTERVAL)
EXISTING GRADE MINOR CONTOUR
27
PROPOSED GRADE MINOR CONTOUR (0.2' INTERVAL)
27
EXISTING STORM DRAIN PIPE
PROPOSED STORM DRAIN PIPE
EXISTING WATER PIPE
PROPOSED WATER PIPE
PROPOSED SEDIMENT FENCE
EXISTING SANITARY SEWER PIPE
PROPOSED SANITARY SEWER PIPE
PROPOSED FLOW DIRECTION
PROPOSED PERVIOUS CONCRETE PAVEMENT
PROPOSED GRADE BREAK
EXISTING AC PAVEMENT PROPOSED AC PAVEMENT EXISTING CONCRETE SURFACING PROPOSED CONCRETE SURFACING EXISTING GRAVEL SURFACING
SF
PROPOSED DITCH FLOW LINE PROPOSED COMPOST SOCK
PROPOSED GRAVEL SURFACING
L LAT
HANDICAP SYMBOL
DESCRIPTION
RADIUS REINFORCED CONCRETE REINFORCED CONCRETE PIPE ROOF DRAIN REDUCER REQUIRED REQUIREMENT REVISION RIGHT OF WAY RIGHT
GUARD POST / BOLLARD
PAD MOUNTED TRANSFORMER
PROPOSED PAINT STRIPE PROPOSED TRUNCATED DOMES
EXISTING BUILDING
PROJECT:
DATE
GAL GM GND GP GPM GRD GV
R, RAD RC RCP RD RED REQD REQT REV R/W, ROW RT
BIKE PATH
ISSUE
FINISH FLOOR FINISH GRADE FIRE HYDRANT FLOW LINE FLANGE FORCE MAIN FEET, FOOT
PIPE PAD MOUNTED TRANSFORMER POINT OF CURVATURE PORTLAND CEMENT CONCRETE PENETRATION PERFORAT(-E, -ED, -ES, -ION) PROPERTY LINE, PLACE POWER VAULT POWER POLE PROPOSED PUMP STATION POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT OF TANGENT PLUG VALVE POINT OF VERTICAL INTERSECTION POLYVINYL CHLORIDE PAVEMENT
COUPLING
----
FF FG FH FL FLG FM FT
P P TRAN PC PCC PEN. PERF P.L., PL POW V PP PROP. PS PSF PSI PT PV PVI PVC PVMT
GAS VALVE
----
EAST EACH END CURB RETURN EXISTING GROUND ELEVATION ELBOW ELECTRIC(-AL) ENGINEER ENTRANCE EDGE OF PAVEMENT EQUAL(-LY) EROSION CONTROL EASEMENT ESTIMATE(-D) END VERTICAL CURVE EXCAVATE EXISTING EACH WAY
ON CENTER OUTSIDE DIAMETER OVERHEAD POWER OWNERSHIP TIE
CAP/PLUG
DESCRIPTION
----
E EA ECR EG EL, ELEV ELB, ELL ELEC ENGR ENTR EP, EOP EQ ESC ESMT EST EVC EXC EX., EXTG. EW
OC OD OHP OT
GAS METER
SYMBOL EXIST. PROP.
VANCOUVER, WASHINGTON
DR DT DW DWG(S)
DEPTH DEGREE(-S) DUCTILE IRON DIAMETER DIMENSION(-S) DUCTILE IRON PIPE DEPARTMENT OF TRANSPORTATION DIMENSION RATIO DETAIL DRY WELL DRAWING(-S)
NORTH NOT APPLICABLE NATURAL GAS NORTHEAST NUMBER NOT TO SCALE NORTHWEST
DESCRIPTION
----
FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C1.1 MASTER LEGEND.dwg
D DEG DI DIA DIM. DIP, D.I.P. DOT
N N/A NAT G, NG NE NO. NTS NW
SYMBOL EXIST. PROP.
DESCRIPTION
CHANNELIZATION SYMBOLS
----
CATCH BASIN CONTROLLED DENSITY FILL CEMENT CUBIC FEET CUBIC FEET PER SECOND CAST IRON PIPE CIRCLE CHECK CENTERLINE CORRUGATED METAL PIPE CLEANOUT COMPACTION CONCRETE CORRUGATED POLYETHYLENE COUPLING COURT CENTER CULVERT CUBIC YARD
MAXIMUM MAUL FOSTER & ALONGI, INC. MANUFACTURER MANHOLE MONUMENT (IN CASE) MINIMUM; MINUTE MISCELLANEOUS MECHANICAL JOINT MONUMENT (SURFACE) MONITORING WELL
SYMBOL EXIST. PROP.
WATER SYMBOLS
----
CB CDF CEM CF CFS CIP CIR CK CL, CMP CO COMP CONC CPE CPL CT CTR CULV CY
MAX MFA MFR MH MIC MIN MISC MJ MON MW
GAS/POWER/TELEPHONE SYMBOLS
400 EAST MILL PLAIN BLVD, SUITE 400 VANCOUVER, WA 98660 PHONE: 360.694.2691 www.maulfoster.com
BEGIN CURB RETURN BUTTERFLY BELOW GROUND SURFACE BUILDING BOULEVARD BENCHMARK BEST MANAGEMENT PRACTICE BLOW-OFF BACK OF CURB BOTTOM BOTTOM OF WALL BEGING VERTICAL CURVE
POUND(-S) LINEAR FEET LONGITUDINAL LEFT
30% DESIGN
BCR BF BGS BLDG BLVD BM BMP BO BOC BOT, BTM B.O.W. BVC
ACOE AD AGG AIR AMSL AP APPD
LB LF LONG. LT
MAUL
ASPH ASSY
ACRE, ASPHALT CONCRETE PAVEMENT ARMY CORPS OF ENGINEERS AREA DRAIN AGGREGATE AIR RELIEF ABOVE MEAN SEA LEVEL ANGLE POINT APPROVED APPROXIMAT(-E, -LY) ASPHALT ASSEMBLY
LOWER GRAND INDUSTRIAL AREA
AC
FOSTER
GENERAL LEGEND
ABBREVIATIONS
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE PROPOSED BUILDING
EXISTING FENCE LINE PROPOSED FENCE LINE EXISTING ROAD CENTERLINE PROPOSED ROAD CENTERLINE EXISTING RIGHT-OF-WAY
EXISTING FLOW DIRECTION EXISTING OVERHEAD POWER EXISTING UNDERGROUND POWER
SHEET TITLE
EXISTING UNDERGROUND TELEPHONE PROPOSED RIGHT-OF-WAY
EXISTING PROPERTY LINE
PL
EXISTING UNDERGROUND GAS PROPOSED PROPERTY LINE
MASTER LEGEND SHEET
C1.1
6" CI
SDMH-AD 30" GRATED LID RIM = 25.97 SUMP 19.3
SDMH 48"CONC. O/S CONE RIM = 26.25 12"CPPL IN(W) 21.72 SUMP 17.4
6" CI
WO707
8" PVC
WO446
6" OD
X STREET
SDMH 48"CONC. O/S CONE RIM = 25.87 12"CPPL OUT(E) 22.67 12"CPPL IN(W) 21.94 8"CPPL IN(S) 23.27 SUMP 17.1
8" CONC
SDMH-AD 24" GRATED LID RIM = 26.22 4"CONC OUT(NW) 24.07 SUMP 23.1
12" CI
6" DI
WB2046
8" DI
8" PVC
MAUL
E. 3rd LOOP
400 E MILL PLAIN BLVD. SUITE 400 VANCOUVER, WA 98660 PHONE: 360.694.2691 www.maulfoster.com
ALONGI FOSTER
8" PVC
8" PVC
8" PVC
8" PVC
8" PVC
8"
SDCB RIM = 25.93 8"CPPL OUT(NW) 23.83 SUMP 22.2
C PV
10/14/15
ET
TRE
12" DI
8" PVC
12" DI
SDMH RIM = 25.20 6"PVC OUT(S) 22.90 SUMP 21.7 ####
12" DI
6" CI
WO707
12" CI
SUMP 22.8
VANCOUVER, WASHINGTON
8" PVC
Y STREET
SDDW 48"CONC O/S CONE RIM = 26.35 12"CONC IN(NE) 16.72 SUMP 16.2
DESCRIPTION
SDMH RIM = 26.02 10"PVC OUT(E) 20.42 10"PVC IN(S) 20.52 SUMP 13.3
SDCB RIM = 25.23 SDCB 10"PVC OUT(E) 24.03 RIM = 25.60 SUMP 21.4 6"PVC OUT(S) 24.10
SDDW RIM = 25.94 10"PVC IN(W) 19.74 SUMP 13.0
6" DI
8" PVC
####
8" PVC
16" DI
SDMH 48" FLAT TOP RIM = 25.96 12"CPPL OUT(W) 23.61 8"CPPL IN(N) 23.96 8"CPPL IN(E) 24.01 SUMP 22.8
16" DI
SDMH RIM = 26.26 12"PVC OUT(E) 22.96 12"PVC IN(S) 23.26
8" PVC
SDCB RIM = 25.72 8"CPPL OUT(S) 23.97 8"CPPL IN(N) 24.07 8"CPPL IN(W) 23.97
SDCB RIM = 25.65 8"CPPL OUT(E) 24.04 SUMP 22.0
####
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C1.2 - EXTG CONDITIONS.dwg
6" OD
6" CI
SDCB RIM = 25.66 10"PVC OUT(SW) 23.86 10"PVC IN(E) 23.86 SUMP 21.8
####
SDCB RIM = 25.59 8"CPPL OUT(E) 24.04 SUMP 22.0
####
XB564
SDMH RIM = 25.67 15"PLASTIC OUT(N)21.72 SUMP 16.1
LOWER GRAND INDUSTRIAL AREA
10" WC
N
16" DI
16" DI
SDMH RIM = 25.81 8"CPPL OUT(S) 24.36 SUMP 21.9
CITY OF VANCOUVER
S .V
8" DI
ENG2006-00196
SDCB RIM = 25.14 8"CPP OUT(N) 22.51 SUMP 20.3
12" DI
CON
C
PV C
8"
SDMH RIM = 25.60 12"PVC OUT(E) 22.30 12"PVC IN(W) 22.30 8"CPP IN(S) 22.00 6"PVC IN(N) 22.45
----
----
----
----
DATE
#### ####
ISSUE
#### ####
#### ####
####
PROJECT:
0363.08.01
DESIGNED: C.GOKCORA DRAWN:
Z.PYLE
CHECKED:
S.FROST
SCALE 0
60'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
8" DI
SDMH RIM = 25.79 12"PVC OUT(W) 19.94 10"PVC IN(NE) 22.79 12"PVC IN(S) 20.19 SUMP 12.8
SDMH RIM = 25.71 48" FLAT TOP 12"PVC OUT(E) 22.26 12"PVC IN(W) 22.26 12"PVC IN(N) 22.26
C
ENG2006-00196
SDCB RIM = 25.72 12"CPPL OUT(S) 23.04 12"CPPL IN(N) 23.14 8"PVC IN(E) 23.72 SUMP 21.5
SDDW 48" FLAT TOP RIM = 26.39 12"CPPL IN(E) 22.22 SUMP 18.7
SDDW RIM = 25.76 12"PVC IN(E) 19.36 SUMP 12.2 SDCB RIM = 25.17 12"PVC OUT(N) 23.12 SUMP 21.2
CON
8"
SDCB RIM = 25.61 8"CPPL OUT(W) 24.06 SUMP 22.6
8" CONC
SDCB RIM = 25.38 12"CPPL OUT(N) 23.23 12"CPPL IN(S) 23.23 SUMP 21.6
SDMH 48" FLAT TOP RIM = 26.36 12'CPPL OUT(W) 22.72 6"PVC IN(N) 23.42 6"PVC IN(E) 23.61 SUMP 19.8
8" CONC
12"
12" DI
####
6" DI
####
8" CONC
12" CI
6" CI
8" PVC
####
8" PVC
SDCB RIM = 25.42 12"CPPL OUT(S) 23.37 12"CPPL IN(E) 23.22
SHEET TITLE
6" DI
EXISTING CONDITIONS
16" DI
PLOTTED ON: 2015-10-14 8:48 AM
----
K
XB564
16" DI
7' A CH
8' CHAINLINK
----
IN INL
E AT
8" PVC
6"
G
CI
GATE
6" CI
SHEET
NOT FOR CONSTRUCTION
C1.2
120'
2)
FOSTER
1) ADJUST ALL EXISTING STORM DRAIN MANHOLE & CATCH BASIN RIMS/GRATES TO MATCH PROPOSED GRADE, UNLESS OTHERWISE NOTED ON PLAN. CONTOURS SHOWN ON C3.1 THRU C3.9 INDICATE 0.2' INTERVALS.
MAUL
3) COORDINATE RELOCATION OF EXISTING POWER STRUCTURES AND WATER UTILITY STRUCTURES WITH CLARK PUBLIC UTILITIES.
400 E MILL PLAIN BLVD. SUITE# 400 VANCOUVER, WA 98660 PHONE: 360.694.2691 www.maulfoster.com
ALONGI
NOTES:
PLOTTED ON: 2015-10-14 9:23 AM
VANCOUVER, WASHINGTON
PROJECT:
ISSUE
DATE
----------
----------
#### #### ####
#### #### ####
#### #### ####
#### ####
####
#### ####
####
DESCRIPTION
30% DESIGN
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.0 MASTER STREET AND STORMWATER PLAN.dwg
LOWER GRAND INDUSTRIAL AREA
10/14/15
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z.PYLE
CHECKED:
S. FROST
SCALE 0
60'
120'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
MASTER STREET AND STORMWATER PLAN SHEET
NOT FOR CONSTRUCTION
C3.0
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ALONGI FOSTER MAUL PLOTTED ON: 2015-10-14 9:40 AM
0.10% 0.80%
PROJECT:
ISSUE
DATE
----------
----------
#### #### ####
#### #### ####
#### #### ####
#### ####
####
####
20
####
EXISTING GRADE AT CENTERLINE
MATCHLINE STA 11+00 SEE C3.2
MATCH EXTG GRADE
DESCRIPTION
NOTE: FUTURE IMPROVEMENTS OF E 1 ST STREET BY OTHERS; NOT PART OF ECOLOGY GRANT APPLICATION
25
####
-1.00%
VANCOUVER, WASHINGTON
FINISH GRADE AT CENTERLINE
CITY OF VANCOUVER
LOWER GRAND INDUSTRIAL AREA
GRADE BREAK STA = 10+50.00 ELEV = 26.565
BVCS: 8+78.00 BVCE: 25.67
EVCS: 9+32.00 EVCE: 25.62
LOW PT STA: 9+08.00 LOW PT ELEV: 25.52 PVI STA:9+05.00 PVI ELEV:25.40 K:30.00 LVC:54.00
GRADE BREAK STA = 8+59.35 ELEV = 25.861
30
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
30' 20'
60' 40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
15 11+00
10+00
9+00
SHEET TITLE 8+59
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.1 STREET AND STORMWATER PLAN AND PROFILE.dwg
10/14/15
STREET AND STORMWATER PLAN AND PROFILE STA 8+59 TO 11+00
Station (Feet)
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET
NOT FOR CONSTURCTION
C3.1
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ALONGI FOSTER MAUL PLOTTED ON: 2015-10-14 9:59 AM
0.10%
EXISTING GRADE AT CENTERLINE
DESCRIPTION
307 LF 12" STRM @S= 0.0022
----------
----------
#### #### ####
#### #### ####
####
#### #### ####
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
20'
40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
15+00
14+00
13+00
12+00
####
PROJECT:
15 8+59 11+00
####
STRM MH C STA 12+49.82 RIM 27.22' 12" IE 22.51' IN (NE) 12" IE 22.51' 22.50' OUT (SW)
####
20
STRM MH B STA 11+59.26 RIM 27.35' 8" IEIE22.64' 12" 22.31'ININ(N) (NE) 12" 22.31'IN IN(N) (NE) 8" IEIE22.64' 12" IE 22.31' OUT (W)
MATCHLINE STA 15+00 SEE C3.3
STRM MH A STA 11+51.39 RIM 26.00' 12" IE 22.25' IN (E) EXTG 48" IE 19.25' IN (N) EXTG 48" IE 19.25' OUT (S) CAST NEW MH OVER EXTG CONC STRM
####
####
90 LF 12" STRM @S= 0.0022
DATE
26 LF 12" STRM @S= 0.0022
ISSUE
25
VANCOUVER, WASHINGTON
0.70%
CITY OF VANCOUVER
LOWER GRAND INDUSTRIAL AREA
FINISH GRADE AT CENTERLINE
GRADE BREAK STA = 14+83.69 ELEV = 26.999
SEE C3.1 MATCHLINE STA 11+00
30
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.2 STREET AND STORMWATER PLAN AND PROFILE.dwg
10/14/15
STREET AND STORMWATER PLAN AND PROFILE STA 11+00 TO 15+00
Station (Feet)
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET
NOT FOR CONSTRUCTION
C3.2
STREET LIGHT (TYP) (C.O.V. STD DTL T21-02) (BY OTHERS)
CURB CUTS @ 30' O.C.
FOSTER
DETECTABLE WARNING (TYP) (C.O.V. STD DTL T02-15)
PERPENDICULAR RAMP (C.O.V. STD DTL T02-08)
8+50
.21
RELOCATE EXTG WATR METER
17+00
PRC: 1
18+00
PERPENDICULAR RAMP (C.O.V. STD DTL T02-08)
E 2ND
0
16+0
ST
19+00
:1 PC
PROTECT AND RELOCATE WATR STANDPIPE RELOCATE EXTG POWR POLE
4+
PERVIOUS CONCRETE (SEE DTL SHT C4.0)
40' DRIVEWAY W/OUT SIDEWALK (TYP)
GRADE BREAK STA = 19+07.32 ELEV = 27.021
GRADE BREAK STA = 16+13.52 ELEV = 27.903
.2 E ST 3 C LIN SEE TCH MA
FINISH GRADE AT CENTERLINE
-0.30%
0.70%
-0.10%
25
PROJECT:
ISSUE
DATE
----------
----------
#### #### ####
#### #### ####
#### #### ####
#### #### ####
#### ####
STRM MH D STA 15+56.37 RIM 27.53' 12"IEIE23.52' 23.18'ININ(NE) (N) 8" 8" IEIE23.52' 12" 23.18'IN IN(NE) (N) 12" 12" IE IE 23.18' 23.18' OUT OUT (SW) (SW)
####
20
MATCHLINE STA 19+50 SEE C3.4
SEE C3.3 MATCHLINE STA 19+50
DESCRIPTION
EXISTING GRADE AT CENTERLINE
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
20'
40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
19+00
18+00
17+00
16+00
15 8+59 15+00
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.3 STREET AND STORMWATER PLAN AND PROFILE.dwg
30
10/14/15
VANCOUVER, WASHINGTON
D C4.0
30% DESIGN
C C4.0
A
0 +0 5 1
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10)
LOWER GRAND INDUSTRIAL AREA
.74
RELOCATE EXTG POWR POLE
MATCHLINE STA 19+50 SEE C3.4
80
00
15+
CURB CUTS @ 30' O.C.
PLOTTED ON: 2015-10-14 10:02 AM
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ALONGI
DRIVEWAY WITH DETACHED SIDEWALK (TYP) (C.O.V. STD DTL 01-04A)
MAUL
EXTG SDMH-AD 30" GRATED LID RIM = 25.97 SUMP 19.3
SHEET TITLE
STREET AND STORMWATER PLAN AND PROFILE STA 15+00 TO 19+50
Station (Feet)
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET
NOT FOR CONSTURCTION
C3.3
ALONGI MAUL EXTG ROW
21+00
ADJUST EXTG SSWR MH TO FINISH GRADE EXTG RIM= UNKWN.
PROTECT AND RELOCATE WATR VAVLE
PERVIOUS CONCRETE (SEE DTLSHT C4.0)
22+00
D C4.0 EXTG ROW
PT: 22+04.17
REMOVE EXTG STRM CB EXTG GRATE 25.93 EXTG 8" IE 23.83 OUT(NW) EXTG SUMP 22.2
C C4.0
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10)
STREET LIGHT (TYP) (C.O.V. STD DTL T21-02) (BY OTHERS)
Y ST
SEE C3.3 MATCHLINE STA 19+50
PC: 21+25.63
E 2ND ST 20+00
PARALLEL PARKING MARKINGS (TYP) C.O.V STD DTL T29-50
WITH DETACHED SIDEWALK (TYP) (C.O.V STD DTL 01-04A)
PI: 21+08.16
PT: 19+77.41
RELOCATE EXTG WATR METER
ABANDON EXTG STRM MH EXTG 48"CONC. O/S CONE EXTG RIM 26.25 EXTG 12" IE 21.72 IN(W) EXTG SUMP 17.4 DRIVEWAY
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ABANDON EXTG STRM MH EXTG48"CONC. O/S CONE EXTG RIM 25.87 EXTG12" IE 22.67 OUT(E) EXTG12" IE 21.94 IN(W) EXTG 8" IE 23.27 IN(S) EXTG SUMP 17.1
FOSTER
RELOCATE EXTG POWR POLE
PLOTTED ON: 2015-10-14 10:05 AM
-0.10%
-0.10%
DESCRIPTION
25
VANCOUVER, WASHINGTON DATE
----------
----------
#### #### ####
#### #### ####
#### #### ####
#### #### ####
PROJECT:
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
20'
40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
22+00
21+00
20+00
15 8+59
####
20
####
SEE C3.3 MATCHLINE STA 19+50
MATCHLINE STA 22+50 SEE C3.5
####
EXISTING GRADE AT CENTERLINE
ISSUE
FINISH GRADE AT CENTERLINE
GRADE BREAK STA = 21+00.00 ELEV = 26.832
30
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.4 STREET AND STORMWATER PLAN AND PROFILE.dwg
MATCHLINE STA 22+50 SEE C3.5
30% DESIGN
LOWER GRAND INDUSTRIAL AREA
10/14/15
STREET AND STORMWATER AND PROFILE STA 19+50 TO 22+50
Station (Feet)
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET
NOT FOR CONSTRUCTION
C3.4
PLOTTED ON: 2015-10-14 10:21 AM
26+58
20 20
15 15
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
NOT FOR CONSTURCTION PROJECT:
0
DRAWN: Z. PYLE
CHECKED: S. FROST
20'
SHEET
C3.5
-------
-------
DATE
####
####
----
----
####
####
####
####
DESCRIPTION
EXISTING GRADE AT CENTERLINE
ISSUE
####
#### ####
####
####
VANCOUVER, WASHINGTON
30% DESIGN
LOWER GRAND INDUSTRIAL AREA
25
####
####
-0.22%
####
MATCH EXTG GRADE
####
0.20%
26+00
GRADE BREAK STA = 24+34.20 ELEV = 26.929
FINISH GRADE AT CENTERLINE
25+00
-0.10%
24+00
GRADE BREAK STA = 22+90.64 ELEV = 26.642
GRADE BREAK STA = 8+59.35
30
23+00
SEE C3.4 MATCHLINE 22+50
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.5 STREET AND STORMWATER PLAN AND PROFILE.dwg
10/14/15
0363.08.01
DESIGNED: C. GOKCORA
SCALE 40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
STREET AND STORMWATER PLAN AND PROFILE STA 22+50 TO 26+57
FOSTER
ALONGI 400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
MAUL
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ALONGI FOSTER MAUL PLOTTED ON: 2015-10-14 10:35 AM
-0.11%
25 EXTG GRD 20' OFF L
177 LF 12" STRM @S= 0.0022 FINISH GRD AT CURB FLOWLINE
VANCOUVER, WASHINGTON
NOTE: FUTURE IMPROVEMENTS OF E 1 ST STREET BY OTHERS; NOT PART OF ECOLOGY GRANT APPLICATION
30% DESIGN
LOWER GRAND INDUSTRIAL AREA
DATE
----------
----------
#### #### ####
#### #### ####
#### #### ####
#### ####
####
#### ####
PROJECT:
0363.08.01
DESIGNED: C. GOKCORA
103+00
102+00
101+00
99+75
15
100+00
STRM MH J STA 99+75.64 RIM 27.86' 12" IE 21.90' IN (E) EXTG 48" IE 18.90 IN (N) EXTG 48" IE 18.90 OUT (S) CAST NEW MANHOLE OVER EXTG CONCRETE STRM
####
MATCHLINE STA 104+00 SEE C3.7
20
DESCRIPTION
STRM MH K STA 101+52.46 RIM 25.90' 8" IE 22.62' IN (N) 12" IE 22.29' OUT (W)
ISSUE
GRADE BREAK STA = 103+01.23 ELEV = 25.729
EXTG GRD AT CENTERLINE
0.15%
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.6 STREET AND STORMWATER PLAN AND PROFILE.dwg
30
END CURB RETURN BEGIN 1ST ST. CURB, OFFSET 20' L GRADE BREAK STA = 100+39.61 ELEV = 25.334
N. V STREET, STA:8+59.00 = 1ST STREET, STA: 100+24.70
10/14/15
DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
Station (Feet)
20'
40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
PROFILE VIEW OF E 1st St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET TITLE
STREET AND STORMWATER PLAN AND PROFILE STA. 99+75 TO 104+00 SHEET
NOT FOR CONSTRUCTION
C3.6
400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
ALONGI FOSTER MAUL -0.11%
0.24%
25
ISSUE
DATE
----------
----------
#### #### ####
#### #### ####
####
#### #### ####
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE 0
20'
40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
107+00
106+00
105+00
####
PROJECT:
15 104+00
####
STRM MH J STA 99+75.64 RIM 27.86' 12" IE 21.90' IN (E)
####
MATCHLINE STA 108+00 SEE C3.8
SEE C3.6 MATCHLINE STA 104+00
20
####
####
DESCRIPTION
FINISH GRD AT CURB FLOWLINE
SHEET TITLE
STREET AND STORMWATER PLAN AND PROFILE STA 104+00 - 108+00
Station (Feet) PLOTTED ON: 2015-10-14 10:39 AM
30% DESIGN
NOTE: FUTURE IMPROVEMENTS OF E 1 ST STREET BY OTHERS; NOT PART OF ECOLOGY GRANT APPLICATION
VANCOUVER, WASHINGTON
EXTG GRD AT CENTERLINE
LOWER GRAND INDUSTRIAL AREA
EXTG GRD OFF 20' L
GRADE BREAK STA = 107+01.68 ELEV = 25.277
30
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.7 STREET AND STORMWATER PLAN AND PROFILE.dwg
10/14/15
Station (Feet)
PROFILE VIEW OF E 1st St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
SHEET
NOT FOR CONSTRUCTION
C3.7
PLOTTED ON: 2015-10-14 10:48 AM
Station (Feet) 111+00
20
PROJECT:
15
Station (Feet)
PROFILE VIEW OF E 1st St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
NOT FOR CONSTRUCTION 0
DRAWN: Z. PYLE
CHECKED: S. FROST
20'
SHEET
C3.8
-------
-------
DATE
####
####
ISSUE
####
####
----
----
####
####
####
DESCRIPTION
FINISH GRD AT CURB FLOWLINE
####
FINISH GRD AT CURB FLOWLINE
####
-0.68%
VANCOUVER, WASHINGTON
30% DESIGN
LOWER GRAND INDUSTRIAL AREA
0.16%
####
0.24%
####
25 EXTG GRD 20' OFF L
####
####
BEGIN 1ST ST WIDENING SECTION STA 109+90
####
END Y ST. CURB RETURN BEGIN 1ST ST. CURB GRADE BREAK STA = 109+90.61 ELEV = 25.801
NOTE: FUTURE IMPROVEMENTS OF E 1 ST STREET BY OTHERS; NOT PART OF ECOLOGY GRANT APPLICATION
####
MATCHLINE STA 112+00 SEE C3.9
EXTG GRD 20' OFF L END HALF STREET OVERLAY STA: 109+76.69
110+00
EXTG GRD AT CENTERLINE END 1ST ST. CURB BEGIN Y ST. CURB RETURN GRADE BREAK STA = 109+00.63 ELEV = 25.747
30
109+00
108+00
SEE C3.7 MATCHLINE STA 108+00
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.8 STREET AND STORMWATER PLAN AND PROFILE.dwg
10/14/15
0363.08.01
DESIGNED: C. GOKCORA
SCALE 40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
STREET AND STORMWATER PLAN AND PROFILE STA 108+00 - 112+00
FOSTER
ALONGI 400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
MAUL
15 115+75 15
PROFILE VIEW OF V St - E 2nd St - Y St HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' VERTICAL EXAGGERATION: 10
NOT FOR CONSTRUCTION
20 PROJECT:
0
#### #### -------
DATE
#### -------
ISSUE
#### ####
####
####
DRAWN: Z. PYLE
CHECKED: S. FROST
SHEET
C3.9
20'
----
----
####
####
####
####
DESCRIPTION
VANCOUVER, WASHINGTON
30% DESIGN
LOWER GRAND INDUSTRIAL AREA
-0.93%
####
FINISH GRD AT CURB FLOWLINE ####
-0.16%
####
NOTE: FUTURE IMPROVEMENTS OF E 1 ST STREET BY OTHERS; NOT PART OF ECOLOGY GRANT APPLICATION
####
25 END 1ST WIDENING SECTION GRADE BREAK STA = 115+00.47 ELEV = 24.403
GRADE BREAK STA = 114+06.60 ELEV = 25.275
EXTG GRD AT CENTERLINE
115+00
0.39%
114+00
GRADE BREAK STA = 112+04.09 ELEV = 25.069
30
113+00
SEE C3.8 MATCHLINE STA 111+75
Elevation (Feet)
PLOTTED BY: Stacy Frost FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C3.9 STREET AND STORMWATER PLAN AND PROFILE.dwg
20
112+00
PLOTTED ON: 2015-10-14 10:56 AM
10/14/15
EXTG GRD 20' OFF L
0363.08.01
DESIGNED: C. GOKCORA
SCALE 40'
NOTE: BAR IS ONE INCH ON ORIGINAL DRAWING. IF NOT ONE INCH ON THIS SHEET, ADJUST SCALE ACCORDINGLY.
SHEET TITLE
STREET AND STORMWATER AND PROFILE STA 112+00 - 115+53
FOSTER
ALONGI 400 E MILL PLAIN BLVD. SUITE #400 VANCOUVER, WA 98660 PHONE: 360-694-2691 www.maulfoster.com
MAUL
14'
14'
ALONGI
C L 14'
14'
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10)
TYPE E-1 BARRIER CURB (C.O.V. STD DTL T01-10) 0.5%
0.5%
0.5%
8" PERVIOUS CEMENT CONCRETE 8" DRAINAGE AGGREGATE BASE
6' BIKE LANE
TYPE E-1 BARRIER CURB (C.O.V. STD DTL T01-10)
PLOTTED ON: 2015-10-14 9:02 AM
PLOTTED BY: Lindsey Crosby
0.5%
8' ORNAMENTAL FENCE
6' PERVIOUS CEM CONC SW
5.5'
C L
10' PARKING
14'
0.5' CURB 10' PARKING
14'
JH KELLY BIORETENTION FACILITY
DESCRIPTION
VARIES 23'-35' R/W VACATION
VARIES 55'-67' R/W
6' PERVIOUS CEM CONC SW
6.0' BIORETENTION FACILITY
0.5' CURB
5.0' A/C PAVEMENT
R/W
29.5'
0.5' PERVIOUS CEM CONC CURB
PERVIOUS CEM CONC SIDEWALK SECTION
E. 1ST ST. HALF-WIDTH (FUTURE BY STA 100+32 - 109+76 OTHERS) R/W
R/W
40.5'
4' PLANTER
4" MIN DEPTH CLEAN UNIFORM GRADED AGGREGATE
R/W
F
STA 19+11 - 21+08
6' BIORETENTION FACILITY
2" PLANE AND AC PAVMT OVERLAY (C.O.V. STD DTL T05-01A & B)
PAVEMENT RESTORATION PER C.O.V. STD DTL T05-01A
8" PERVIOUS CEMENT CONCRETE 8" DRAINAGE AGGREGATE BASE
E. 2ND ST. SECTION
UNCOMPACTED SUBGRADE
2% - 3% PER PLAN
70' R/W
EXTG R/W
FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C4.0 STREET CROSS SECTIONS.dwg
0.5%
10' ROW VACATION
14'
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10) PAVEMENT RESTORATION PER C.O.V. STD DTL T05-01A
2%
WHEEL STOP
0363.08.01
DESIGNED: C. GOKCORA DRAWN:
Z. PYLE
CHECKED:
S. FROST
SCALE
DRAWING NOT TO SCALE
0.5%
0.5%
PROJECT:
DATE
6' PERVIOUS CEM CONC SW
C L
10/14/15
ISSUE
0.5' CURB
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10)
D
4" MIN DEPTH PERVIOUS CEMENT CONCRETE
----
6' BIORETENTION FACILITY
10' PARKING
14'
42.4'
EXTG R/W
14'
37.6'
----
0.5' CURB
C L
80' R/W
----
R/W
R/W
6' PERVIOUS CEM CONC SW
0.5' CURB
STA 15+18 - 18+90 22+04 - 22+30
STA 11+20 - 15+18
49'
31'
C
VANCOUVER, WASHINGTON
B
80' R/W
6' BIORETENTION FACILITY
E. 2ND ST. SECTION
E. 2ND ST. SECTION
R/W
STA 9+05 - 11+00
R/W
A
8" PERVIOUS CEMENT CONCRETE 8" DRAINAGE AGGREGATE BASE
----
V ST. SECTION
8" PERVIOUS CEMENT CONCRETE 8" DRAINAGE AGGREGATE BASE
----
TYPE E-1 BARRIER CURB (TYP) (C.O.V. STD DTL T01-10)
6' PERVIOUS CEM CONC SW
6' BIORETENTION FACILITY
----
6' PERVIOUS CEM CONC SW
14'
2' CEM CONC COLLAR
2001 NW 19TH AVE, SUITE 200 PORTLAND, OR 97209 PHONE: 971.544.2139 www.maulfoster.com
14'
C L
6' BIORETENTION FACILITY
CITY OF VANCOUVER
0.5' CURB
FOSTER
C L
0.5' CURB
MAUL
0.5' CURB
LOWER GRAND INDUSTRIAL AREA
0.5' CURB
VARIES 78'-109' R/W
R/W
VAR.
46'
R/W
VAR.
32'
R/W
R/W
100'
R/W
R/W
78' R/W
R/W ACQUISITION (STA 15+72 - 18+77) VARIES 7.5' - 29'
SHEET TITLE
8" PERVIOUS CEMENT CONCRETE 8" DRAINAGE AGGREGATE BASE
E
Y ST. SECTION STA 22+66 - 26+00
WIDENING SECTION (FUTURE BY G E 1ST ST ROAD STA 109+90 - 115+00 OTHERS)
STREET CROSS SECTIONS SHEET
C4.0
1 SUBGRADE 18" MIN DEPTH BIORETENTION SOIL MEDIA (SEE NOTES ON THIS SHT)
18" MIN DEPTH BIORETENTION SOIL MEDIA (SEE NOTES ON THIS SHT)
SUBGRADE 12" MIN DEPTH NO. 4 COURSE AGGREGATE (DRAIN ROCK) WSDOT 9-03.1(3)C OR AS APPROVED 6" PERF UNDERDRAIN
6" PERF UNDERDRAIN
20 MIL PVC LINER
PLOTTED ON: 2015-10-14 9:07 AM
PLOTTED BY: Lindsey Crosby
BIORETENTION FACILITY REGULAR PAVEMENT SECTION
B
SCALE: NTS
BIORETENTION FACILITY PERVIOUS PAVEMENT SECTION SCALE: NTS
C
BIORETENTION FACILITY NOTES SCALE: NTS
A 6'
6' BIORETENTION FACILITY
6" DRAINAGE AGG BASE INTO THE BIORETENTION FACILITY
4" PERVIOUS CONC. S/W ON 3" MIN DEPTH 5/8"-0 CRUSHED AGGREGATE
PLAN BIORETENTION FACILITY (SEE DTL A AND B)
BIORETENTION FACILITY (SEE DTL A AND B)
DRIVEWAY (C.O.V. DTL T01-04A)
ATRIUM GRATE
2' BOTTOM
2001 NW 19TH AVE, SUITE 200 PORTLAND, OR 97209 PHONE: 971.544.2139 www.maulfoster.com
10/14/15
6" RISER HEIGHT 4" ATRIUM GRATE (BY RAINBIRD OR APPD EQUAL) AND 4" RISER
8" PERVIOUS CEM CONCRETE 8" DRAINAGE AGGREGATE BASE
----
FILENAME: G:\00_MFA Civil 3D\00_PROJECTS\0363.08.01 - City of Vancouver (Lower Grand Employment Area)\PLANS\C4.1 STORMWATER DETAILS.dwg
A
2" REVEAL 2" REVEAL
3
8" MIN DEPTH
1 PROJECT: SUBGRADE
18" MIN DEPTH BIORETENTION SOIL MEDIA (SEE NOTES ON THIS SHT) 12" MIN DEPTH NO. 4 COURSE AGGREGATE (DRAIN ROCK) WSDOT 9-03.1(3)C OR AS APPROVED
DATE
12" MIN DEPTH NO. 4 COURSE AGGREGATE (DRAIN ROCK) WSDOT 9-03.1(3)C OR AS APPROVED
NOTES: 1) WHERE EXISTING SOILS MEET THE MINERAL AGGREGATE GRADATION REQUIREMENTS, THOSE SOILS MAY BE AMENDED RATHER THAN IMPORTING MINERAL AGGREGATE. 2) COMPOST SHALL MEET THE DEFINITION OF "COMPOSTED MATERIALS" IN WAC 173-350-220 AND PRODUCED BY A COMPOSTING FACILITY PERMITTED BY THE WA DEPT OF ECOLOGY. 3) COMPOST PRODUCT MUST ORIGINATE A MINIMUM OF 65% BY VOLUME FROM RECYCLED PLANT WASTE DEFINED AS SOURCE-SEPARATED YARD AND GARDEN WASTES, WOOD WASTES, AGRICULTURAL CROP RESIDUES, WAX-COATED CARDBOARD, PRECONSUMER VEGETATIVE FOOD WASTES, OTHER SIMILAR SOURCE-SEPARATED MATERIALS THAT THE JURISDICTIONAL HEALTH DEPARTMENT DETERMINES TO HAVE A COMPARABLE LOW LEVEL OF RISK IN HAZARDOUS SUBSTANCES, HUMAN PATHOGENS, AND PHYSICAL CONTAMINANTS. 4) A MAXIMUM OF 35% BY VOLUME OF OTHER APPROVED ORGANIC WASTE DEFINED AS MEAT AND POSTCONSUMER SOURCE-SEPARATED FOOD WASTES OR OTHER SIMILAR SOURCE-SEPARATED MATERIALS THAT THE JURISDICTIONAL HEALTH DEPARTMENT DETERMINES TO HAVE A COMPARABLE LOW LEVEL OF RISK IN HAZARDOUS SUBSTANCES AND PHYSICAL CONTAMINANTS, BUT ARE LIKELY TO HAVE HIGH LEVELS OF HUMAN PATHOGENS, INCLUDING POSTCONSUMER FOOD WASTE, BUT NOT INCLUDING BIOSOLIDS, MAY BE SUBSTITUTED FOR RECYCLED PLAN WASTE. MANURE AND BEDDING FROM HERBIVOROUS ANIMALS THAT THE JURISDICTIONAL HEALTH DEPARTMENT DETERMINES TO HAVE A COMPARABLE LOW LEVEL OF RISK IN HAZARDOUS SUBSTANCES AND PHYSICAL CONTAMINANTS WHEN COMPARED TO A TYPE 1 FEEDSTOCK AND MIXED MUNICIPAL SOLID WASTES, POSTCOLLECTION SEPARATED OR PROCESSED SOLID WASTES, INDUSTRIAL SOLID WASTES, INDUSTRIAL BIOLOGICAL TREATMENT SLUDGES, OR OTHER SIMILAR COMPOSTABLE MATERIALS THAT THE JURISDICTIONAL HEALTH DEPARTMENT DETERMINES TO HAVE A COMPARABLE HIGH LEVEL OF RISK IN HAZARDOUS SUBSTANCES, HUMAN PATHOGENS AND PHYSICAL CONTAMINANTS SHALL NOT BE USED. 4) COMPOST SHALL HAVE A MOISTURE CONTENT RANGE SUCH THAT THERE IS NO VISIBLE FREE WATER OR DUST PRODUCED WHEN HANDLING THE MATERIAL. 5) COMPOST SHALL BE TESTED IN ACCORDANCE WITH THE U.S. COMPOSTING COUNCIL "TESTING METHODS FOR THE EXAMINATION OF COMPOST AND COMPOSTING (TMECC) AS ESTABLISHED IN THE COMPOSTING COUNCIL'S "SEAL OF TESTING ASSURANCE" (STA) PROGRAM.
DESCRIPTION
2 1
ISSUE
2
MINERAL AGGREGATE COMPONENT OF BIORETENTION SOIL MEDIA SIEVE SIZE PERCENT PASSING 3/8" 100 #4 95-100 #10 75-90 #40 25-40 #100 4-10 #200 2-5
1
----
1
----
2" REVEAL 3
----
2" REVEAL 3
8" MIN DEPTH
"FINE COMPOST" (100% PASSING 1" SIEVE) (TMEC02.02-B)