Liquid crystal Thermography

Liquid crystal Thermography • What are Thermochromic Liquid Crystals‐ – Thermochromic Liquid Crystals (TLC) are materials that change their reflected...
Author: Kathryn Marsh
74 downloads 1 Views 1MB Size
Liquid crystal Thermography •

What are Thermochromic Liquid Crystals‐ – Thermochromic Liquid Crystals (TLC) are materials that change their reflected  colour as a function of temperature when illuminated by white light. Hence,  reflect visible light at a different wavelengths.

Liquid crystal Phases •





Thermotropic liquid crystals – Thermotropic phases are those that occur in a certain temperature range. If the temperature rise is too high, thermal motion will destroy the delicate cooperative ordering of the LC phase, pushing the material into a conventional isotropic liquid phase. At too low temperature, most LC materials will form a conventional crystal Nematic phase – rod‐shaped organic molecules have no positional order, but they self‐align to have long‐range directional order with their long axes roughly parallel Smectic phases – The smectic phases, which are found at lower temperatures than the nematic, form well‐defined layers that can slide over one another in a manner similar to that of soap • Blue phases ‐ Regular three‐dimensional cubic structure • Discotic phases ‐ Disk‐shaped LC molecules can orient themselves in a layer‐like fashion

Liquid Crystals • • • • • • • • •



Liquid crystal is a unique organic material which exists between the solid and  the isotropic liquid phase.  In between these temperature limits, it shows a certain molecular structure that  resembles the crystalline state.  Here, the incident light is scattered selectively and forms the basis of  temperature measurement. The material is in the amorphous solid phase below a certain temperature and a  pure liquid beyond an upper limit. Liquid crystals possess a helical structure with a characteristic pitch  The pitch length of the helix is in the range of the wavelength of visible light.  The pitch length changes with an external stimulus such as temperature.  In a second family of liquid crystals, the molecular structure responds to the  applied shear stress.  The fundamental chemical structure is unaffected by the external stimulus and a  liquid crystal coating can respond repeatedly to the physical change and can be  used reliably as a temperature sensor. Since the technique involves using a (white) light source for illumination and a  detector for recording the scattered light, LCT classifies as an optical technique.

Encapsulated Crystal

Pitch p = p(T) and usually increases with increasing temperature λ ref    = Selectively reflected wavelength of light dependent on p(T)

Temperature • • • • • •

• • • •

The lowest temperature where liquid crystals scatter visible light is called the event  temperature. At a temperature below the event temperature, liquid crystals will be in the solid state  and will appear transparent.  At a temperature above the clearing point temperature, it will enter the pure liquid  state and will revert back to being transparent.  Outside this range, the scattered light is negligible and, when viewed through a  camera, the sheet would appear black.  At the clearing point temperature, the helical pitch of the liquid crystals exceeds the  wavelengths of visible light.  The reflected colour spectrum of liquid crystals will vary continuously from the longer  wavelengths (red) corresponding to event temperature to shorter wavelengths (blue)  corresponding to the clearing point temperature.  At intermediate temperatures, the surface would take on a green colour. Liquid crystals transmit a significant amount of the incident light with virtually no  modification.  Therefore, they are viewed against a non‐reflecting (black) background.  This precaution prevents the transmitted light from getting reflected without  adversely affecting the interpretation of selectively scattered light from the liquid  crystals.

LC Material ‐ Types ‰ Encapsulated — the liquid crystal material is encapsulated in a 5‐10 micron sphere suspended in a water based binder material‐‐ provides excellent       protection. The micro‐encapsulation process offers chemical contaminant  resistance and radiation protection. ‰ Unencapsulated —the material is in its native form‐‐ susceptible to  contamination, however, once applied, produces brilliant colours. ‰ The liquid crystals can be either  narrow band ‐ 1 or 2oC  wide band formulation ‐ 5 and 30oC. A colour/temperature designator describes the response of a typical liquid  crystal chemical make up. This helps in selecting the liquid crystal composition  for a particular application.

LCT – Clinical  • •

• • • •

The clinical application of liquid crystals in medicine involves skin application to define relative temperatures which are modified by underlying conditions.  Some cholesterol ester derivatives in the liquid crystal form are highly sensitive to  variations in skin temperature which they convert almost instantaneously into  reversible colour values.  Cholesteric liquid crystals are organic com‐ pounds which exhibit mechanical  properties of liquids and optical properties of solids.  The substance is unique in that the molecule is neither in a three dimensional  array as in a solid nor in a free form as in a liquid.  Instead, cholesteric liquid crystals form layers which are free to slide over one  another or revolve around a fixed axis.  This property is responsible for the colour changes associated with differentials in  temperature to the areas on which they are applied. 

• • •



Normally the liquid is colourless, but the molecules realign themselves in response  to temperatures of adjacent substances. The colours that are produced are the reverse of the conventional colour scheme  associated with heat.  The spectrum of colours produced from these substances begins with red at the  cool end of the spectrum and progresses through green to deep blue for the warm  end of the scale. The underlying base coat of black is visible when the recorded temperature is  beyond either end of the temperature scale.

Applications ‐ Orthopedic Materials and Method: • The technique of application begins with obtaining a black background before the  cholesteric crystals are applied.  • This can be accomplished either by applying a plastic sheet, such as the Vidrape(types  of adhesive) that is used in surgery, that has been painted black, or by direct  application of a black  paint to the area to be investigated.  • The clear liquid cholesteric crystal solution is then sprayed on the area.  • Because the crystals are affected by subsurface temperature, variations in color appear. • The area investigated is then photographed.  • A 35 mm single reflex camera is used. • The camera is equipped with a rotating polarizing filter.  • Strobe light (xenon) being a cool light is the most suitable light source. • The flash unit, too, must be equipped with a polarizing filter, eliminating the  reflections of the fatty cholesteric liquid crystals.  • The photographs are analysed for areas of relative temperature differential. • In the evaluation of joint disease, a baseline study is carried out and then follow‐up  studies are conducted at timely intervals to evaluate the effectiveness of the treatment  program.

Cineradiography

•X‐ray image was recorded directly onto film/Fluoroscopic Screen •The methods were not of great value until the speed of films, fluorescent screens and optical systems had improved together with increased outputs from X‐ray tubes and improvements in focal spot size were attained.

Cinefluorography

Motion picture study of successive images appearing on a fluoroscopic screen. 

Stereoscopic radiography • Two Images of left and right eye is obtained by using various methods. • Combined to give a 3D picture. • Stereoscopy creates the illusion of three‐dimensional depth from images on a two‐ dimensional plane. • Stereoscopic images can enhance the spatial position information for images and improve the observation effects of the spatial structure relation of a examined object. A method most usually used for obtaining an X‐ray stereogram is to shift the X‐ray source or move an imaging screen between two exposures. Another method is to catch two images at different angles as an X‐ray stereogram by rotating the X‐ray source and imaging screen or rotating the object by a small angle.

magnification radiography • Magnification is especially useful when parts being  inspected and their details are very small. • The farther the test specimen is from the image  detector, the greater the magnification achieved. • The amount of magnification can be calculated using  the following formula.  M = (a + b) / a M = magnification  a = distance from the source to the object b = distance from the object to the detector •One disadvantage of magnification is that the field of  view is decreased

Microradiography •



process by which a radiograph of a small or very thin object is produced on  photographic film under conditions permitting subsequent microscopic  examination or high resolution enlargement of the radiograph. The resulting Negative is examined under a high power optical microscope

Microradiography ‐ Detectors •

Indirect‐sensing detector  – a fluorescent‐screen optical‐lens coupling system using a high‐sensitivity  pickup‐tube camera. – A scintillator converts X‐ray photons to visible light that is detected by the  photoconductive layer of the pickup tube.  – advantage of the indirect‐sensing detector is that the fluorescent screen and  lens can be changed quite easily.



Direct‐sensing Detector – amorphous photoconductive Se‐As alloy target

Microradiography ‐ Detectors Direct X‐RAY SATICON CAMERA Indirect HARPICON CAMERA

neutron radiography • • • •



Neutron radiography is the process by which film is exposed by first passing neutrons  through an object to produce a visible image of the materials that make up the object. Neutron imaging is the process of making an image with neutrons. The resulting image is based on the neutron attenuation properties of the imaged object,  and these attenuation properties distinguish neutron and X‐ray images Attenuation of X‐rays is proportional to density – denser materials stop more X‐rays – whereas neutron absorption is not. Some light materials such as boron strongly absorb  neutrons while many commonly used metals allow most neutrons to pass through them. Typical NR‐detectors are:  – X‐ray film/converter plate assemblies  – Track ‐ Etch films  – imaging plates  – scintillator / camera – amorphous silicon (a‐Si) or flat panel detectors 

Microwave Imaging • • • •

Microwave imaging (MWI) is an attractive alternative modality for breast imaging. The procedure is comfortable and the clinical system cost is a small fraction of the  cost of an X‐ray system, making it affordable for widespread screening. The procedure poses no safety hazards, and the potential is significant for  detecting very small tumors in early stages of development. A microwave imaging system is composed of a  – microwave source,  – a network of computer‐controlled switches,  – transmission lines feeding an array of transmitting and receiving antennas,  – a chamber whose interior contains the breast to be imaged,  – a detector, and a computer for data postprocessing/ image formation.

Schematic



• • •

The frequency chosen for microwave breast imaging must be low enough to  provide adequate depth of penetration, but high enough to allow the use of small  antenna array elements. The greatest contrast in breast tissue occurs in the frequency range 600 MHz‐1 GHz  and specific contrast values were given at 800 MHz. At an operating frequency of 800 MHz, the free space wavelength is λ0 = 37.5 cm. In normal breast tissue, the wavelength is reduced to 9.375 cm, assuming that the  dielectric constant is 16 for normal breast tissue.

• •





Three different methods of microwave breast imaging methods are discussed briefly below Passive microwave Imaging : Passive methods incorporate radiometers to measure temperature differences in the breast, detecting tumours based on their increased temperature compared to normal tissue. Hybrid Microwave‐Acoustic Imaging: Hybrid: methods use microwave energy to select and rapidly heat tumours and ultrasound transducers to detect pressure waves generated by the expansion of the heated tissues. Due to higher conductivity of malignant breast tissue, more energy is deposited in tumours, resulting in selective heating of these lesions. The tumours expand and generate pressure waves which are detected by ultrasound transducers. Active Microwave Imaging: Active methods involve illuminating the breast with  microwaves and then measuring transmitted or reflected microwave signals, and  forming images with these data. 

Microwave Antennas employed in Medical Imaging •



Monopole Antenna – By using monopole antennas the entire imaging region can be illuminated by  placing them close to the target whereas in other antennas the distance has to  be greater in order to provide sufficient illumination coverage. Bow‐tie Antenna – antenna is constructed by structurally modifying the conventional microstrip  bowtie antenna design. The parameters, such as the distance to the image  plane, flare angle of the bow, and dimensions of the antenna, are found to affect  the bandwidth.





Vivaldi Antenna – The Vivaldi antenna, a form of the tapered slot radiator, has  been shown to produce performance over a wide bandwidth  limited only by the traditionally used slotline to microstrip  transition Pyramidal Horn Antenna – antenna consists of a pyramidal horn radiation cavity,a metallic  ridge, and a curve metallic launching plane terminated with  resistors.

Thermal Imaging ‐ Detectors