Welcome to the Region of Waterloo’s Water Supply Study for Fountain Street and Maple Grove Area Class EA Public Information Centre #1 This is an opportunity for you to provide comments and input.

October 7, 2009

Problem Statement The Provincial Places to Grow Act and the Region of Waterloo Growth Management Strategy, will require additional water capacity in the Region’s Integrated Urban Water Supply System (1). The Region has identified a potential high yield aquifer in the general area of Maple Grove Road and Fountain Street. This project will study in detail the potential for optimizing water supply sources in this area. Note: 1. The Waterloo Regional Integrated Water System (IUS) is a unified system that provides water to the Cities of Cambridge, Kitchener and Waterloo , and Towns of Elmira and St. Jacobs using as water sources the Grand River and groundwater wells located throughout the Region.

Limits of Study Area Area Features • Mostly farmland with recent industrial/commercial developments • Wetlands • Surface Water Courses •Grand River •Speed River •Freeport Creek Site Location Study area is bound by Middle Block Road to the North, the Grand River to the West, Hwy 8 & Hwy 401 to the South and Beaverdale Road to the East.

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

Background •

The Study area currently includes a production well, P16, located on Fountain Street.



As part of the IUS Study, a test well, FSTW1-06 was installed 1km west of P16, behind the Region’s Maple Grove Operations Centre. The test well produced promising yield.



A Schedule ‘C’ Class EA undertaking will determine the best location for a new production well in the area and determine the maximum sustained pumping rate.

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

The EA Process Agency/Public Consultation Notice of Commencement (Posted on the Region website and in The Record)

WE ARE HERE

Mandatory Review Agency/Public Consultation

PHASE 1 Identify & Describe the Problem or Opportunity

PHASE 2 Evaluate Alternative Solutions & Establish the Preferred Solution

PHASE 3 Identify Alternative Design, Environmental Effects & Preferred Design

PHASE 4 Prepare Environmental Study Report (ESR) Documenting Phases 1-3

Mandatory Review Agency/Public Consultation

Discretionary Review Agency/Public Consultation Public Information Centre (Posted on the Region website and in The Record)

File ESR

Opportunity for Part II Order Request (Formerly referred to as “bump-up’)

Discretionary Review Agency/Public Consultation Public Information Centre (Posted on the Region website and in The Record)

• Municipalities are required to follow the planning process as outlined in the Municipal Engineers Association’s (MEA) Municipal Class Environmental Assessment (EA) Document (as amended in 2007). • The process gives the public an opportunity to provide input to ensure that municipal projects consider not only economic and technical factors, but also social and environmental factors. The end result is a publicly supported and environmentally responsible project.

PHASE 5 Complete Drawings & Documents – Proceed to Construct, Operate & Monitor Project

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

Existing Municipal Well – P16 • •

• •

P16, a 508mm dia. production well was constructed in 1986 Water quality noted elevated levels of iron and manganese, typical for wells in this area A 7-day pumping test was conducted at P16 in 2007 P16’s yield is 17 L/s

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

Existing FSTW1-06 Site • FSTW1-06, a 150mm dia. test well was constructed in 2006 • A 72 hour pumping test was conducted at FSTW1-06 in 2007 • Test pumping produced a yield much higher than anticipated. • Water quality testing revealed elevated iron and manganese concentrations, which are typical for wells in this area

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

30-Day Pumping Test and Monitoring Program Proposed Work Plan: New Well Installation • Install a new 305mm dia. test well, FSTPW1-09 in close proximity to existing test well FSTW1-06 • Construct two new monitoring wells in the area Pump Test & Monitoring Program • Communication to the public through direct mail-outs to potentially affected residents and through the Region of Waterloo website • Conduct door-to-door survey to collect well water level information and establish monitoring points

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

30-Day Pumping Test and Monitoring Program Proposed Work Plan cont’d •

Conduct water level monitoring at least two weeks prior to the commencement of the 30-day pumping test



Undertake a 30-day pumping test to determine if longterm water taking is sustainable at P16, and at the FSTPW1-09 site



Conduct water level and water quality monitoring in the study area within wetland areas, creeks, monitoring wells and private wells during the pump test.



Use the testing and monitoring program to study the potential effects that municipal water taking may have on private wells and environmentally significant features in the area. Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

30-Day Pumping Test and Monitoring Program Potential Resident Concerns • Water from the pumping test should be directed to storm sewer to eliminate potential for the recharge into the local aquifer. • Water will be directed to storm sewer with sufficient capacity and then discharge to the Grand River via overland flow. • Residents and business owners will be assured of uninterrupted water supply during the test. • A licensed well technician will be available 24/7 to investigate potential impacts from pumping throughout the test and to supplement water supplies for any impacted wells (if required). • Quiet generators will be used at the FSTPW1-09 well location. • Residents in the area are encouraged to enable the monitoring team to have their private wells monitored during the pumping test so that any water level changes caused by pumping can be documented. Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

Proposed Schedule

Current

Winter 2010

Winter 2010

Spring 2010

Summer 2010

Fall 2010

•Public Information Centre (PIC)#1 (Opportunity for the public to provide input and inform themselves about the project.)

• Install Test Well • Perform Pumping Test

• Evaluate test results and any received public input to identify and define alternative strategies • PIC #2

• Evaluate alternative strategies and any received public input to determine the Preferred Alternative • PIC #3

• Complete the Environmental Study Report • Allow for 30Day Public Review Period

• Initiate the detailed design of the preferred alternative

Phase 2

Phase 2

Phase 2

Phase 3

Phase 4

Phase 5

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment

How You Can Provide Input The EA Process encourages public input and participation. Any comments collected will become part of the project file and will be used to evaluate the alternative solutions. Please place your completed comment sheet in the Comment Box tonight or send it via mail by Friday October 30, 2009 to one of our project team members listed below. Mr. Jorge Cavalcante, P.Eng Manager, Engineering & Planning Regional Municipality of Waterloo Transportation and Environmental Services, Water Services 150 Frederick Street, 7th Floor Kitchener, ON N2G 4J3 Phone: 519-575-4412 Fax: 519-575-4452 Email: [email protected]

Mr. Greg Spere, C.E.T. Vice President Municipal Division MTE Consultants Inc. 520 Bingemans Centre Drive Kitchener, ON N2B 3X9 Phone: 519-743-6500 Fax: 519-743-6513 Email: [email protected]

Region of Waterloo – Water Supply Study for Fountain Street and Maple Grove Area Class Environmental Assessment