ISO

Part No. 29270520RC VW Multivan / Caravelle T5 Transporter T5 Window van 05/03 05/03 09/09 09/09 Transporter T5 Panel van 05/03 09/09 Electric w...
Author: Marian Walsh
5 downloads 2 Views 865KB Size
Part No. 29270520RC VW

Multivan / Caravelle T5 Transporter T5 Window van

05/03 05/03

09/09 09/09

Transporter T5 Panel van 05/03

09/09

Electric wiring kit for towbars / 13-pin / 12 Volt / ISO 11446

IMPORTANT!

Fitting instructions

Installation of the towing electrics kit must be undertaken by a specialist workshop or an appropriately qualified person. Before starting work, you must read the installation instructions through completely. After installing the towing electrics kit, the installation instructions should be kept with the vehicle service documentation.

In case of missing a rear fog lamp on the trailer, it should be retrofitted.

All claims under the guarantee will lapse in case of improper use or modification of the towing electrics kit or any of its component parts. When driving without a trailer or load carrier, any adapter installed must be removed from the electrical socket. We reserve the right to alter the design, content or colour. We accept no liability for any errors in these instructions. All details and illustrations are nonbinding.

The trailer module is not diagnostics-capable. If the manufacturer’s diagnostics processes or software-supported test mechanisms generate error reports directly or indirectly linked with trailer operation, the trailer module must be disconnected from the leads to the trailer socket and a new diagnostic process initiated.

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

We accept no responsibility and give no guarantee for technical and electrical modifications made after the initial operation of the towing electrics kit by the vehicle manufacturer and which may lead, for example to malfunction of the trailer socket or its peripheries.

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

1/9

3x

4x

10x

90270328

4-5, 12-13

19, 22-29

7-11

20, 21, 23-29

87270955 / 21.10.2009 © ConWys AG

3-5, 14-17

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

2/9

SYMBOL EXPLANATION left (58-L) respectively right (58-R) tail light

cigarette lighter / accessory socket

12 V

stop light (54) / high mounted, third stop light (54)

turn signal indicator left

loudspeaker / buzzer

P

Park Distance Control switch / source of function

turn signal indicator right

Reverse

everse

-

+

30+ +

15+

B+/30

20A

-

rear fog light(s)

Connect together

reversing light(s)

Disconnect

Permanent power supply / 13pin socket, chamber 9

Look at / See further information

charging wire for trailer fridge / 13pin socket, chamber 10

Look carefully at selected area

trailer / trailer recognition

Present / Occupied / OK

Permanent current power supply

Not present / Not occupied / Not OK

Ground or Earth (31)

left

ground connection battery terminal lug

right

positive connection battery terminal lug

acoustic indication

fuse / fuse capacity 20 Ampère

attention / important advice

90500760

MANUAL

IMPORTANT! In order to avoid mal-functions and damage to the vehicle’s electrical system the earth terminal must be disconnected from the vehicle’s battery before starting work! Both the trailer module and the vehicle’s control unit for the electrical system can be damaged during work on the data bus connections if the battery is not disconnected! Please pay attention to the manufacturer’s instructions when disconnecting and reconnecting the vehicle’s battery!

1

90010216

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

3/9

90270143

2

90270173

3

L

R

90270144

4

R

L

R

L

5

90270145

90500580

7

GB

D

E

BK

Black

Schwarz

Negro

Noir

RD

Red

Rot

Rojo

Rouge

F

I

90270146

P

NL

DK

N

S

Nero

Preto

Zwart

Sort

Svart

Svart

Rosso

Vermelho

Rood

Rød

Rød

Röd

CZ

H

Musta

Cerná

Fekete

Czarny

Punainen

Cervená

Piros

Czerwony

FIN

PL

GN

Green

Grün

Verde

Vert

Verde

Verde

Groen

Grøn

Grønt

Grön

Vihreä

Zelená

Zöld

Zielony

OR

Orange

Orange

Naranja

Orange

Arancione

Laranja

Oranje

Orange

Orange

Orange

Oranssi

Oranzová

Narancs

Pomaranczowy

VT

Violet

Violett

Violeta

Violet

Viola

Violeta

Violet

Violet

Fiolett

Violett

Violetti

Fialová

Ibolya

Fioletowy

PK

Pink

Pink

Pink

Rose

Rosa

Cor-de-Rosa

Paars

Pink

Pink

Rosa

Pinkki

Ruzová

Rózsaszín

Rózowy

BL

Blue

Blau

Azul

Bleu

Blu

Azul

Blauw

Blå

Blått

Blå

Sininen

Modrá

Kék

Niebeski

YL

Yellow

Gelb

Amarillo

Jaune

Giallo

Amarelo

Geel

Gul

Gult

Gul

Keltainen

Slutá

Sárga

Zólty

WT

White

Weiss

Blanco

Blanc

Bianco

Branco

Wit

Hvid

Hvitt

Vit

Valkoinen

Bílá

Fehér

Bialy

BR

Brown

Braun

Marrón

Brun

Marrone

Marrom

Bruin

Brun

Brunt

Brun

Ruskea

Hnedá

Barna

Brazowy

GY

Grey

Grau

Gris

Gris

Grigio

Cinzento

Grijs

Grå

Grått

Grå

Harmaa

Zedá

Szürke

Szary

87270955 / 21.10.2009 © ConWys AG

6

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

4/9

Belegung der Steckdose / Maximale Ausgangsleistung Socket configuration / Maximum power output Correspondance des contacts de la prise / Puissance de sortie maximale Abbinamento della presa / Uscita di alimentazione massima Indeling van de stekkerdoos / maximaal uitgangsvermogen

ISO 11446

1-8

8

90500316

STOP

9

20 amp.

1

10 11

Reverse

8 7

2

15 amp.

4

15+

6

10

3 12

+

+

-

YL

21W

2

BL

42W

3/31

WT

4/R

GN

21W

5/58-R

BR

52W

6/54

RD

63W

7/58-L

BK

52W

8

PK

42W

9

OR

240W

10

GY

180W

11

WT/BK

5 12

13 9

9

-

30+

1/L

90500550

10

13

WT/RD

90020157

1 = GN/WT 3 = GN

1 2 3

1 = BL/BK 2 = WT/GN

1 2 3

3 = BL

11

13

90500288

90270149

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

12

90270148

14

90270113

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

5/9

90270148

15

16

90270149

P 19 - 28

30 - 35

P 29 - 35 90270176

17

18

90500318

P MY 2007

19

BR/WT

90270151

P MY 2007

20

BR/WT

90270151

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

6/9

P

MY 2007 PDC control unit 16-pin BR

21

P

MY 2007 PDC control unit 16-pin BR

22

P

P

Option A: chamber 5 not occupied

16-pin BR

chamber 5

WT/GN 90270154

23

P

24 Option B: chamber 5 occupied

90270155

P

chamber 5

25

90180162

87270955 / 21.10.2009 © ConWys AG

BR/WT

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

26

90270156

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

7/9

P PDC control unit

everse

16-pin BR

27

90270153

90500505

28

P

OPTIONAL for voltage control relay WT OR

GY

_

_

15 amp.+

WT/GN

90010122

-

15+ 20 amp.

29

30

+

+

90500763

+

-

Part-no. 22400512RC

B+/30

everse

MANUAL

31

90500004

32

90500507

34

90500544

Optional: Adapter socket 62400003 13-pin

33

7-pin

90500332

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

8/9

Diagnostics

1

Set up trailer operation R

Autologic

OEM Diagnostics Activate the C2 trailer flashing control lamp Encoding the control unit: • Select STG 09 (vehicle's electrical system) • STG encoding - function 07 • Make a note of the current coding value! • Add the number 2 to the current encoding value: +00002 - trailer coupling installed! (e.g. 10000 + 00002 = 10002) • Save new code • Check function of the C2 trailer flashing control with trailer

35

Autologic® Independant Vehicle Diagnostics • Start Diagnostics – select ‘VAG’ • Run fault code check & clear any faults or PRESS ‘SKIP’ • Press ‘NEXT’ • Press ‘ELECTRONIC CENTRAL ELECTRICS’ • Press ‘CODING’ • Select ‘Manual Coding’ • Make a note of the number shown in the lower box ( e.g 1000) • Press ‘EDIT’ button next to this • On the key pad, add the figure ‘2’ to the code number ( e.g 1000 + 2 = 1002), press ‘OK’ • Press ‘CODE’, then press ‘Continue’ • Check correct function of trailer lamp in instrument display

90270184

87270955 / 21.10.2009 © ConWys AG

Right Connections (UK) Limited 7 Churchill Buildings, Queen Street, Wellington, Telford, Shropshire TF1 1HT

Hotline: +44 0871 226 2030 Fax - UK only: 0870 759 8366

Web: www.rightconnections.co.uk email: [email protected]

9/9