Installation Instructions

Ultra Sauna Electric Heaters Installation Instructions • • • • • • • • • • • • • • • • • • • • • Scandia/Vico Heater Sizing Guide Heater must be i...
Author: Opal Campbell
5 downloads 0 Views 903KB Size
Ultra Sauna Electric Heaters

Installation Instructions • • • • • • • • • • • • •

• • • • • • • •

Scandia/Vico Heater Sizing Guide

Heater must be installed by a certified professional Heater must be installed according to local codes Plastic must be removed from shell before operating heater Do not touch the heater Do not cover the heater Never hose down the sauna Sauna door must always open outward Sauna door can never include a lock Do not install more than one heater in a room Only use an aroma-stone when using fragrances Never leave children unattended Sauna bathing is not suitable for those with health problems. Consult a doctor before using

Model series 30 series 45 series

Watts 3000 4500

Volt options 240 240

Phase options 1 1

Square feet 20 ft 30 ft

Square meters 6m 9m

60 75 90 12 15 18

6000 7500 9000 12000 15000 18000

240 240 240 240 208 208

1 1 1/3 1/3 1/3 1/3

42 ft 64 ft 88 ft 140 ft 205 ft 240 ft

13 m 19.5 m 27 m 44 m 63 m 73 m

series series series series series series

Ultra Sauna Electric Heaters - small (dim - 10 3/4" x 16" x 23 1/4") Model

Sauna Room General Guidelines Heater must be installed according to code and by an licensed electrician The sauna should be constructed of cedar. Plastic must be removed from shell before operating heater. Do not treat of varnish the sauna wood. Fill the heater only with Scandia high-density rocks Check rock tray twice a year cleaning all dirt and rock pieces. The warning signs and sauna usage plaque must be displayed. Sauna room sizing is based on standard 7 foot ceilings.

Watts Volts Phase Amp

Max Room Size

20 sq ft (6.1 sq meters )

30240

3000

240

1

12.5

30208

3000

208

1

14.4

20 sq ft (6.1 sq meters )

45240

4500

240

1

18.8

30 sq ft (9.2 sq meters)

45208

4500

208

1

21.7

30 sq ft (9.2 sq meters)

60240

6000

240

1

25

42 sq ft (12.8 sq meters )

60208

6000

208

1

28.9

42 sq ft (12.8 sq meters )

Model

Watts Volts Phase Amp

75240

7500

240

1

31.3

64 sq ft (19.5 sq meters)

75208

7500

208

1

36.1

64 sq ft (19.5 sq meters)

90240

9000

240

1

37.5

88 sq ft (27 sq meters)

90240-3

9000

240

3

21.7

88 sq ft (27 sq meters)

90208

9000

208

1

43.3

88 sq ft (27 sq meters)

90208-3

9000

208

3

25

88 sq ft (27 sq meters)

Model

Watts Volts Phase Amp

Ultra Sauna Electric Heaters - medium (dim - 14" x 16" x 28 3/4") Max Room Size

Ultra Sauna Electric Heaters - large (dim - 18" x 26" x 29")

Sauna Room Venting Guidelines Sauna room should be vented according to manufacturers specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous for the health. Heater should be positioned near the door or as close to the door as possible without impeding traffic flow. The inlet vent should be below the heater or near the base of the heater. Outlet vent should be just below the top bench on the opposite side or near the opposite side of the heater.

Superior Sauna & Cabin Mfg LLC

www.SuperiorSaunas.com

Max Room Size

12240

12000

240

1

50

140 sq ft (44 sq meters)

12240-3

12000

240

3

29

140 sq ft (44 sq meters)

12208

12000

208

1

57.7

140 sq ft (44 sq meters)

12208-3

12000

208

3

33.3

140 sq ft (44 sq meters)

15240

15000

240

1

62.5

205 sq ft (63 sq meters)

15240-3

15000

240

3

36.2

205 sq ft (63 sq meters)

15208

15000

208

1

72.2

205 sq ft (63 sq meters)

15208-3

15000

208

3

41.7

205 sq ft (63 sq meters)

18240

18000

240

1

75

240 sq ft (73 sq meters)

18240-3

18000

240

3

43.4

240 sq ft (73 sq meters)

18208

18000

208

1

86.6

240 sq ft (73 sq meters)

18208-3

18000

208

3

50

240 sq ft (73 sq meters)

26865 State Hwy 118, Ashland, WI 54806 USA

[email protected]

Tel: 715.746.2268

Fax: 715.746.2168

Ultra Sauna Electric Heaters

Installation Instructions Sauna Heater and Guard Rail Placement Guide Watts Watts Watts A B C D E F G H I J

1800 3000 4500 16 10 3/4 5 23 1/4 17 21 11 13 10 45

6000 7500 9000 16 14 5 28 3/4 16 22 1/2 14 13 10 40

12000 15000 18000 26 18 9 29 21 28 10 3/4 22 10 39 To Ceiling (H-7ft) J A

H C

C

L

F D

G B

I

Plastic must be removed from shell before operating

H

To wall or guard rail

Ultra Sauna Electric Heaters M odel 60240

W a tts 6000

V o lt s 240

Am ps 25

P hase 1

S u p p ly / G r o u n d 3 - # 10

B re a k e r 30

W ir e s C o n t r o l t o H e a t e r 3- #10 / 2- #14

60208

6000

208

2 8 .9

1

3 - #8

40

3- #8 / 2- #14

7524 0

750 0

240

3 1.3

1

3 - #8

40

3- #8 / 2- #14

7520 8

750 0

208

3 6 .1

1

3 - #8

50

3- #8 / 2- #14

90240

9000

240

3 7 .5

1

3 - #8

50

3- #8 / 2- #14

90240-3

9000

240

2 1.7

3

4 - # 10

30

4- #10 / 2- #14

90208

9000

208

4 3 .3

1

3 - #6

60

3- #6 / 2- #14

90208-3

9000

208

25

3

4 - # 10

6400

4- #10 / 2- #14

12 2 4 0

12 0 0 0

240

50

1

3 - #6

60

7- #10 / 2- #14

12 2 4 0 - 3

12 0 0 0

240

29

3

4 - #8

40

4- #8 / 2- #14

12 2 0 8

12 0 0 0

208

5 7 .7

1

3 - #4

70

7- #10 / 2- #14

12 2 0 8 - 3

12 0 0 0

208

3 3 .4

3

4 - #8

50

4- #8 / 2- #14

Line Feeds/Ground From Breaker

Control Box

Heater

Line feeds/ground from Control box to Heater

M odel 75240 75208 90240 9 0 2 4 0 -3 90208 9 0 2 0 8 -3 12240 1 2 2 4 0 -3 12208 1 2 2 0 8 -3

W a tts 7500 7500 9000 9000 9000 9000 12000 12000 12000 12000

V o lts 240 208 240 240 208 208 240 240 208 208

Am ps 3 1 .3 3 6 .1 3 7 .5 2 1 .7 4 3 .3 25 50 29 5 7 .7 3 3 .4

P hase 1 1 1 3 1 3 1 3 1 3

S u p p ly /G r o u n d 3 - #8 3 - #8 3 - #8 4 - #10 3 - #6 4 - #10 3 - #6 4 - #8 3 - #4 4 - #8

B re a k e r 40 50 50 30 60 60 60 40 70 50

W ir e s C o n tr o l to H e a te r 3- #8 / 2- #14 3- #8 / 2- #14 3- #8 / 2- #14 4- #10 / 2- #14 3- #6 / 2- #14 4- #10 / 2- #14 7- #10 / 2- #14 4- #8 / 2- #14 7- #10 / 2- #14 4- #8 / 2- #14

F Controls (60 minute timer) 3000 Watts to 6000 Watts Heaters Single-phase only 240/208 Volts Series 30 45

Watts 3000 4500

Volts 240 / 208 240 / 208

Amps 12.5 / 14.4 18.8 / 21.7

60

6000

240 / 208

25 / 28.9

Phase Mas Room Size 1 20 sq ft 1 30 sq ft F Controls (60 min 1 42utesqtimer ft

version ) 240V S ingle Phase

Circuit Breaker 20 30

Wires from control to heater 3 qty #14 ga 3 qty #10 ga 3 qty #10 ga

30/40

Heater

Co ntrols

Thermostat High -Limit Line Timer to H igh-Limit on Base of Heat er

High Limit

P ower Feed W ires Pow er to L1 and L2

T1

Heat er Elem ents H eater Element Line T2 t o heater elem ents

L1

T2

L2

Timer

H Controls (for T-Model Heaters) 3000 Watts to 6000 Watts Heaters Single-phase only 240/208 H Controls (thermostat on heater )Volts 240V Sing le phase

Heater

Controls

H igh -Limit Line Timer to H igh -Limit on Base of H eater Power Feed W ires Pow er to L1 and L 2

Thermostat T1

L1

T2 H igh Limit

L2

Timer

H eater Element s H eater Elem ent Line T2 t o heater element s

H eater

C ontrols

Series

Watts

Volts

Amps

Phase

Mas Room Size

Circuit Breaker

Wires from control to heater

30 45 60

3000 4500 6000

240 / 208 240 / 208 240 / 208

12.5 / 14.4 18.8 / 21.7 25 / 28.9

1 1 1

20 sq ft 30 sq ft 42 sq ft

20 30 30/40

3 qty #14 ga 3 qty #10 ga 3 qty #10 ga

B Controls (60 minute timer) 7500 Watts to 9000 Watts Heate rs Single-phase only 240/208 Volts. For T-Model Heaters Series 75 90

Watts 7500 9000

Volts 240 / 208 240 / 208

SIngle Phase Powe r F eed

1

Amps 31.3 / 36.1 37.5 / 43.3

2

Phase 1 1

Mas Room Size 56 sq ft 80 sq ft

Circuit Breaker 40 50

Wires from control to heater 3 qty #8 ga - 2 qty #14 3 qty #8 ga - 2 qty #14

Groun d Sca n di a el ec tri c h e at e rs a re U L list e d

Ground T erm inal Timer Con tacto r

High Limit Switch

T-stat

To con ta ctor co ils

1

2

To cont actor coils Conta ctor

Element 2

Element 1

1

1

2

2

Control Box

3

4

Sauna Heater

A Controls (60 minute timer) 7500 Watts to 9000 Watts Heaters Single-phase only 240/208 Volts SIngle Phase Power Feed

1

2

Ground Scandi a electric heaters are UL li sted

Ground Terminal

T-stat Contactor 1

2

To co ntacto r coi ls

High Limit Switch To contactor coils

Timer

Contactor

E leme nt 2

Element 1

1

2

Con trol Box

1

2

3

4

S auna Heate r

A2-24 Controls 7500 Watts to 9000 Watts Heaters Single-phase only 240/208 Volts SIngle Phas e Power Feed

1

Ground

2

Scandi a el ectric heaters are UL li sted

24 HR Timer

Ground Terminal

Contactor

High Limit Sw itch To contac tor coils

T-st at

1

2 Cont act or

T o contactor coils

Element 2

Element 1

1

2

3

2

1

Control Box

4

Sauna Heater

A3 Controls (60 minute timer) 9000 Watts to 12000 Watts Heaters Three-phase only 240/208 Volts Series 90-3

Watts

9000 240 / 208

Volts

21.7 / 25

Phase 3

120-3

12000 240 / 208

29 / 33.4

3

Three Phase Power Feed

Amps

1 2

3

Mas Room Size Circuit Breaker 80 sq ft 60 120 sq ft

Supply Wires (incl ground) 4 qty #8 ga

Wires from control to heater 4 qty #8 ga - 2 qty #14

4 qty #8 ga

4 qty #8 ga - 2 qty #14

40

Ground Scandi a el ectri c heaters are UL l isted

T-stat

Ground Terminal C ontac tor

1

Timer

2 High Limit Switc h

To contactor coils To contactor coils

Contactor

Element 3 Element 2

Element 1 1 To High Limit

1

2

2

3

4

3

Control Box

Sauna Heater

5

6

A3-24 Controls 7500 Watts to 12000 Watts Heaters Three-phase only 240/208 Volts 24 Hour TImer

Ground Three Phase Power Feed

Scandia electric heaters are UL listed

1

2

3

Contactor 1

Ground Terminal

24 Hour Controls

2 High Limit Switch

Contactor

Element 3 Element 2

Element 1

1

2

1

To High Limit

3

Control Box

Series Watts 120 12000

Volts 240 / 208

Amps 50 /57.7

2

3

4

5

6

Sauna Heater

Phase Mas Room Size Circuit Breaker 1 120 sq ft 60/70 1 180 sq ft 70/90

Supply Wires (incl ground) (240V, 3qty #6) 208V, 3qty #4)

Wires from control to heater 7 qty #10 ga - 2 qty #14

(240V, 3qty #4) 208V, 3qty #2)

7 qty #10 ga - 2 qty #14

180 sq ft

50

(240V, 4qty #8) 208V, 4qty #6)

7 qty #10 ga - 2 qty #14

75 / 86.6

3 1

240 sq ft

90/100

3qty #2

7 qty #10 ga - 2 qty #14

43.4 / 50

3

240 sq ft

60

4qty #6

7 qty #10 ga - 2 qty #14

150

15000

240 / 208

62.5 / 72.2

150-3

15000

240 / 208

36.2 / 41.7

180

18000

240 / 208

180-3

18000

240 / 208

E2 Control for Scandia/Vico 15KW and 18KW Heater 208V and 240V (Three Confi guration) Three Phase Power Feed

Ground Sc a nd i a el e ct ric h ea t e rs a re U L lis t ed

1

2

3

Contactor 1

4

5

6

Contactor

Ground Terminal

2

High Limit Switch

To contactor coils

Contact or L1

Contactor To contactor coils

L2

To High Limit

T2

T1

Elemen t 3 Fuse Assemblies

To High Limit

1

2 3

4

Element 2

Elemen t 1

5 6

5

3

6

4

2

1

To Elements

Control Box

S auna Heater

E2 Control for Scandia/Vico 12KW,15KW and 18KW Heater 208V and 240V (Single Phase Configuration) Single Phase

Ground Sca n d ia e le ct ric h e at e rs a re UL li st ed

1

2

3

Cont act or 1

4 5 6

C ontactor

Ground Terminal

2

H igh Limit Sw it ch

To contactor coils

C ontactor L1

Contactor To contactor coils

L2

To H igh Limit

T2

T1

Ele ment 3 T o High Limit

Fuse Assemblies

1

2

3

4

E lement 2

E lement 1

5 6

6

3

5

2

To E lement s

Control Box

Sa una Heater

4

1

E2-24 Control for Scandia/Vico 15KW and 18KW Heater A2 Control for S candia/Vico 12KW, 15 KW and 1 8KW Hea ters 208V and 240V (Three Confi guration) For THREE PHASE ONLY24 Hour Timer Ground

Three Phase Power Feed

S candia el ectric heaters are UL li sted

1

2

3

4

Cont actor 1

5

Ground Terminal

6

Contactor

2 High Limit Switch

Contactor

Contactor

To High Limit

Elemen t 3

To High Limit

Fuse Assemblies

Ele ment 1

2

3

4

5

5

3

6 1

Ele me nt 2 4

2

1

6

To Elements

S auna Heater

Con tro l B ox

E2-24 Control for Scandia/Vico 12KW,15KW and 18KW Heater A2 Con trol fo r S ca ndia/V ico 12 KW, 15K W an d 1 8K W He ate rs - For 208V and 240V (Single Configuration) 24Hour Timer S ing lePhase PHA SE ONL Y Groun d

Single Phase Pow er Feed

S ca n d ia el e ct ric h e a t e rs a re U L li st e d

1

2

3

C onta ctor 1

4

5

Grou nd Te rmina l

6

C ontac tor

2 H igh Limit S w it ch

C o ntact or

C on tact or

T o H igh Lim it

El ement 3

To H igh Limit

F use A ssem blie s

El ement 1 6

1

2

3

4

E lemen t 2

5

3

5

2

6

To Elem ents

Co ntro l Box

S aun a H eater

4

1

Control Box Location Commercial Installations – Most commercial facilities with 24 hour timers place the control panel in a service room near the sauna or the electrical room . When the room is not near the sauna the thermostat can be placed near the room separate from the control box . Other configurations include placing the control box near the sauna but having the the controls placed behind the cover (see fig 1). For conduit and wire size , type and quantities see specific heater wire diagram charts . Residential Installations – Place the control box on the side of the door that opens , approximately 12" from the door opening and 52" from the bottom (see fig. 1) . For conduit and wire size , type and quantities see specific heater wire diagram charts .

12"

52"

Door opens on the left

Door opens on the right

12"

52"

F Control Rough-In Dimensions Control Cover Plate

Control Box 4"

6"

3 "

8"

10 1/2" 0 15

45 30

22ga Brushed Aluminum

I8 ga Galvanized Paint -loc Steel

A/B Control Rough -In Dimensions Control Box

Control Cover Plate 9 ¾”

8 ¼” 4"

14 ¼”

12 ¼” 0 45

15 30

22 ga Brushed Aluminum

I8 ga Galvanized Paint -loc Steel

* NOTE: rough-in ½” extra on box dimensions

E/E24 Control Rough -In Dimensions Control Box

Control Cover Plate 13 ¼”

12 ¼” 4"

14" 15 ½” 0 45

15 30

22 ga Brushed Aluminum * NOTE: rough-in ½” extra on box dimensions

I8 ga Galvanized Paint-loc Steel

Standard Heater /Control Configuration Line Feeds /Ground From Breaker

Thermostat Sensor Bulb

Control Box

Heater Warning Signs Line feeds/ground from Control box to Heater

IMPORTANT NOTES: -

Heater must be installed by a licensed electrician . Heater must be installed inside the sauna room and mounted one foot from the floor . Controls must be installed outside of the sauna room . Thermostat capillary sensor bulb must be located inside the sauna room (horizontal position ) approx . 10 inches from ceiling. All wiring must comply with Local and State ordinances : all wiring into the sauna room must be rated for at least 90 degrees Celsius (194 deg Farenhiet ). Standard sauna ceiling height is 7 feet. Consult all local codes before installation . Warning signs must be installed at eye level on door and above heater . Door must always swing outward. Air intake vent must be installed below heater and an air exhaust vent should be installed .

Commercial Heater /Control Configuration Option #1 Controls near door

Option #2 Controls in remote location

Line Feeds /Ground From Breaker

Line Feeds /Ground From Breaker

Controls behind cover (24 hour timer)

Controls (24 hour timer)

Heater

Line feeds/ground from Control box to Heater

Line feeds /ground from Control box to Heater

IMPORTANT NOTES: -

Heater must be installed by a licensed electrician . Heater must be installed inside the sauna room and mounted one foot from the floor . Controls must be installed outside of the sauna room . Thermostat capillary sensor bulb must be located inside the sauna room (horizontal position ) approx . 10 inches from ceiling. All wiring must comply with Local and State ordinances : all wiring into the sauna room must be rated for at least 90 degrees Celsius (194 deg Farenhiet ). Standard sauna ceiling height is 7 feet . Consult all local codes before installation . Warning signs must be installed at eye level on door and above heater . Door must always swing outward. Air intake vent must be installed below heater and an air exhaust vent should be installed . Thermostat should be placed behind cover and out of control of guests /members . Setting should be no higher than 180 degrees farenheit (85 Celcius)