Installation Guide for SMART Luminaire Control System

Installation Guide for SMART Luminaire Control System Thank you for purchasing SAMJIN’s SMART Luminaire Control System. Before starting installation a...
Author: Marianna Paul
1 downloads 2 Views 678KB Size
Installation Guide for SMART Luminaire Control System Thank you for purchasing SAMJIN’s SMART Luminaire Control System. Before starting installation and use of any product, please be sure to read this installation guide. The appearance and make up of products can be modified without notice for improvement of performance and quality.

SMART CONTROL SYSTEM The SMART control system enables you to control LED and conventional luminaires installed in the building easily through the PC Program and RF Wall Controller, and reduces electricity consumption.

SMART SYSTEM CONFIGURATION

SMART Luminaires

PC

DS WC

LAN cable (CAT5e, 30m max)

EC OS

Non-SMART Light Fixtures

PB (option)

- Radio communication distance between The Wall Controller, Luminaires and Sensors should be less than 25m. - Maximum connection length of LAN cable (CAT5e) between devices is 30m. Device

Function

PC (Mac/Windows) Program

Integrated control of all luminaires in the building through PC

EC (Ethernet Converter)

Communication interface between the PC and the Wall Controllers

WC (Wall Controller)

Control of luminaires by detecting movement and brightness in the individual rooms

OS (Occupancy Sensor)

On/off luminaire control by detecting movement

DS (Daylight Sensor)

Control of luminaires’ brightness by detecting ambient brightness

PB (Power Bridge)

On/off control of conventional lightings through PC

SYSTEM SPECIFICATION Device

Power source

Comm. distance

Quantity

PC (Mac/Windows) Program

PC Power

-

1 or more units

EC (Ethernet Converter)

Adaptor

30m

EC 19 units (Max) per PC

WC (Wall Controller)

EC (LAN Cable)

30m

WC 12 units (Max) per EC

Luminaire 100 units (Max) per 1 WC

OS (Occupancy Sensor)

Luminaire (LAN Cable)

30m

OS 1 unit per monitored area

OS 3 units (Max) per 1 WC

DS (Daylight Sensor)

Sensor (Daisy chain)

30m

DS 1 unit per monitored area

DS 1 unit (Max) per 1 WC

PB (Power Bridge)

AC Power

-

-

Remark

1. Ethernet Converter (ECTP-STUS)

A device for communication interface between the PC and Wall Controllers, using RS485 protocol for Wall Controllers and Power Bridge, TCP/IP for PC

P.C

EC

6 1

2

3

4

5

WC PB (option)

1.1 Parts name for Ethernet Converter 1 DC power terminal – power source from adaptor 2 Connector between Wall Controller and Power Bridge (CAT5e LAN Cable) 3 Indicator Lamp – indication of communication and operation 4 EC ID update C/M 5 PC connection terminal (CAT5e LAN Cable) 6 Reset

2. Power Bridge (PBRS-STUS)

A device for turning on/off conventional lightings without switchboard and control function through exclusive PC program

Front door

1.1 Parts name for wiring terminals 1 AC power terminal - AC input power(100-277V / 16A) 2 Load - CH1~CH4 (4A/CH, Total max current 16A) 3 PC connection terminal (CAT5e LAN Cable)

1

2

3

3. Occupancy Sensor (OSRF - STUS)

Operating according to the preset condition from Wall Controller, on motion detection, luminaires turn on, after preset waiting time without motion detection, luminaires turn off.

cover

4 3 1

5 base

2

3.1 Parts name of occupancy sensor 1 Fresnel Lens - PIR Fresnel Lens 2 ANT - 916 MHz Helical Antenna 3 Indicator Lamp – indication of communication and operation 4 Power supply RJ45 C/N – Power supply from a Lamp (CAT5e LAN Cable), or daisy chain from another sensor (CAT5e LAN Cable) 5 Mounting screw – after wiring, mount the base on the ceiling with two screws, and assemble the cover.

3.2 Detecting Area : within 3 meter radius from the center Ceiling

2.7m

Floor

3m

2

1

0

1

2

3m

4. Daylight Sensor (DSRF - STUS) Operating according to the preset condition from Wall Controller, detecting ambient brightness, when it is brighter than the preset illumination value, the brightness of luminaires decreases. If darker than the preset value, the brightness of luminaires increases.

cover

3

4 1 5 2

base

4.1 Parts name of Daylight Sensor 1 Photo Sensor – detects ambient light intensity 2 ANT - 916 MHz Helical Antenna 3 Indicator Lamp – indication of communication and operation 4 Power supply RJ45 C/N - Power supply from a Lamp (CAT5e LAN Cable), or daisy chain to another sensor (CAT5e LAN Cable) 5 Mounting screw – after wiring, mount the base on the ceiling with two screws, and assemble the cover.

5. Wall Controller (WCRF - SKUS) Controls sensors, dimming level (0-100%) and correlated color temperature (in 50K increments) of SMART luminaires.

5.1 Parts name of Wall Controller

Wall Controller ID Info Luminaire brightness Info

LCD Window AUTOPILOT mode

Luminaire CCT Info

PRESET mode SENSOR mode ID(Group) No, Up/Down Dimming control: manual brightness control Color temperature(K) control: Bulb color(Warm: 2,700K) ~ Daylight color(Cool: 6,500K) Power: On/Off of luminaires

5.2 Wall Controller Function



※ To use the listed functions below, Sensors (occupancy, daylight) should be installed. ※ If the buttons related with sensors are pressed without installed sensors, “No sensor” is displayed on the screen.

1

2

3

4

5

6

7

8

9

10 11

No

Mode

Function

Instructions

Daylight Sensor

As ambient brightness compared with preset value becomes brighter or darker, the brightness of luminaire is automatically controlled.

Setting

After pressing “1”, then touching “7” or “8” makes the brightness of luminaires set to the ambient brightness. While set brightness is blinking in the LCD, pressing “3” completes value setting.

Occupancy Sensor

After preset waiting time without motion detection, luminaires turn off.

Setting

After pressing “1”, then touching “5” or “6” adjusts the delay time to turn-off. Time increases or decreases by 5 seconds

Daylight+Occ. Sensor

Daylight sensors and occupancy sensors detect illumination and motion simultaneously according to the preset value.

Setting Info Verification

Set brightness, color temperature(Kelvin) and Wall Controller ID are displayed.

Autopilot

By 24 hour cycle, it automatically presents similar color temperature to outdoor sun light.

Autopilot+Occ. Sensor

Autopilot function and Occupancy sensors are operating simultaneously according to the preset value.

Setting Info Verification

Set brightness, color temperature(Kelvin) and Wall Controller ID are displayed.

Memory

After setting preferred brightness and color temperature, pressing “3” for more than 3 seconds memorizes current set value as preset condition.

Preset

Pressing “3” returns brightness and color to the preset value.

Group Control

Group selection(1~10) → press “4” and “6” to cycle through each group.

Individual Control

Individual luminaire selection → press “4” and “6” cycle through each luminaire.

1

Sensor 1+1

1+1+1 1+1+1+1

Main

2 Auto 2+2 2+2+2 3~~

Main

Preset

3 5 5+5

Group Luminaire selection

베이스

5+5+5

Main

Setting Info Verification

Set brightness, color temperature(Kelvin) and Wall Controller ID is displayed.

4

“←”

Move

Move to the previous No. in Group or Individual luminaire ID Mode.

6

“→”

Move

Move to the next No. in Group or Individual luminaire ID Mode.

Decrease Brightness

Dimming → when touched, dims by 1%, when held for more than 2 seconds, dims fast.

Increase Brightness

Brightening → when touched, brightens by 1%, when held for more than 2 seconds, brightens fast.

Warmest Color (2700K)

Warmer Color → when touched, decreases by 50K → when held for more than 2 seconds, decreased fast.

Coolest Color (6500K)

Cooler Color → when touched, increases by 50K → when held for more than 2 seconds, increased fast.

On

When touched, luminaires are turned on with the preset brightness and color.

Off

When touched, luminaires are turned off, the green lamp of power button is turned on

7 Dimming 8 9 10 11 11+11

Color Change (Kelvin)

Power