Installation and Maintenance Manual

Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts Thank you for purchasing a DAGR Industrial Lighting fixture – one of the most d...
Author: Bruno Greer
3 downloads 2 Views 526KB Size
Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts

Thank you for purchasing a DAGR Industrial Lighting fixture – one of the most durable LED fixtures on the market. Our lights have been engineered, tested and certified to ensure optimum performance in the industry’s toughest environments. When installed, operated and maintained in accordance with product specifications and instructions, your new LED fixture can be expected to provide many years of reliable lighting performance and energy savings. If you have any questions about the use and maintenance of your DAGR LED fixture, please contact us toll-free at 1.866.203.0040 or email [email protected].

WARNING

WARNING

Important Safety Instructions RISK OF FIRE AND/OR ELECTRIC SHOCK •

This product should be installed and maintained by a qualified Electrician ONLY, in accordance with all applicable electrical codes.



Make sure the power is OFF before installing or servicing. Never attempt to install or remove a fixture from an energized circuit. Disconnect power at fuse or circuit breaker before installing or servicing.



Proper grounding is required to ensure personal safety.



Inspect all units for damage prior to installation.



Do not alter, relocate or remove wiring, lamp holders, ballast, drivers or any other electrical component.



Do not allow flammable or combustible materials to accumulate on fixture.



Always wear appropriate personal protective equipment (PPE) during installation, maintenance or handling.

Important Safety Instructions HAZARDOUS LOCATIONS •

Remove fixture from hazardous locations before attempting any maintenance.



Do not return fixture to service in hazardous locations if seals have been broken or product is damaged.



This fixture is made of aluminum and is not suitable for use in underground mines where explosive atmospheres may exist.



To maintain explosion proof integrity, make sure all threads are fully engaged.

Product Unpacking

This fixture has been packed to avoid damage during transit. Inspect the fixture to confirm there is no damage prior to installation. Do not install a damaged fixture or change fixture components.

DAGRlighting.com 1.866.203.0040

Page 1

MP700.1407.IM May 2014

Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts

Operating Environments

LED technology differs from previous forms of lighting. The driver is capable of accepting a range of input voltages, but requires a consistent supply of power. Drivers are able to withstand minor voltage drops and surges, but should not be subject to frequent power fluctuations. The fixture should not be operated at voltage and current inputs below or exceeding those listed under the unit’s operating parameters. Lighting circuits should be designed to ensure sufficient and stable voltage and current are delivered to the unit. Temperature limits for hazardous locations are listed on the certificate of conformance as well on the product label attached to the fixture and presented later in this document. For optimal performance and longevity, the standard operational environment of the fixture should not routinely exceed 35°C. Continuous operation at high ambient temperatures will decrease the longevity of the driver. Under abnormally high ambient temperatures, the driver will decrease power output as ambient temperatures approach and exceed 50oC and may go into protection mode.

Wiring

Wiring of this product must be performed by a qualified electrician and all electrical connections made in accordance with the National Electrical Code, any applicable local code requirements and hazardous location requirements. Luminaire Wire Guide

Phase (Live)

Neutral

Ground

Black

White

Green

Brown

Blue

Green and Yellow

USA and Canada European Union (EU) (IEC 60446)

Typical Current Draw:

5A / 120VAC

Mounting

This fixture can be mounted using the mounting hardware provided. Do not mount in a fashion that puts strain on the electrical cord or cord connector. Note: Fixture may become damaged and/or unstable if not installed properly. Ensure that all mounting hardware is fully tightened and will not loosen. If mounted in areas subject to vibration, ensure mounting methodology will not allow wear or shear on mounting hardware. A secondary method of securing the fixture to the support can be employed as an additional safety measure.

Maintenance

Perform visual, electrical, and mechanical inspections on a regular basis. The environmental and operating conditions, in conjunction with a preventive maintenance program, should be used to determine inspection frequency. We recommend an Electrical Preventive Maintenance Program as described in the National Fire Protection Association Bulletin NFPA No. 70B: Recommended Practice For Electrical Equipment Maintenance (www.nfpa.org). To prevent heat build-up, remove dust from the LED housing. The lens should be cleaned periodically to ensure continued lighting performance. Do not use an abrasive, strong alkaline or acid cleaner as damage may result.

DAGRlighting.com 1.866.203.0040

Page 2

MP700.1407.IM May 2014

Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts

Warranty

Fixtures come with a 5-year warranty when installed in a fixed location, such as in a building. The product has a limited 1-year warranty when installed and used in any mobile application. Visit DAGRlighting.ca for full warranty details.

Product Dimensions (mm)

Unit Weight 13 kg

Units per Box 1

DAGRlighting.com 1.866.203.0040

This product consists of: • Housing and heat sink • Power supply • LED arrays • Cover plate with lens and reflector • Mounting bracket (not shown) • Electrical cord and cord connector (not shown)

Page 3

MP700.1407.IM May 2014

Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts

Mounting Assembly Step 1 – Lay out materials. Step 2 – Place the appropriate lock washer on each bolt, followed by the flat washer.

Step 3 – On one side of the fixture, place a mounting plate onto back of the fixture, followed by the mounting angle indicator. Step 4 – Align all pieces and secure loosely with the appropriate bolts. Step 5 – Repeat step 3 on the opposite side of the fixture.

Step 6 – Loosely secure the mounting bracket onto the angle indicators by placing a bolt through the center of the indicators and securing directly to the bracket. Step 7– Tighten bolts to secure mounting plate and angle indicator to the housing. Step 8– Adjust mounting bracket to the desired angle, and then tighten center bolt as well as angle indicating bolt.

DAGRlighting.com 1.866.203.0040

Page 4

MP700.1407.IM May 2014

Installation and Maintenance Manual MP700 Multi-Purpose LED 400 Watts

Certification and Conformance

This product conforms to UL and CSA standards for LED luminaires. Conformance certifications can be found at http://www.labtestcert.com/labtest/

Limitation of Liability

All statements, technical information and recommendations contained in this document are based on information and test results we believe to be reliable. The accuracy or completeness thereof is not guaranteed. As conditions of use are outside our control, the purchaser should determine the suitability of the product for his/her intended use and assumes all risk and liability whatsoever in connection therewith. NOTE: Product specifications and dimensions are subject to change without notice.

DAGRlighting.com 1.866.203.0040

Page 5

MP700.1407.IM May 2014