HP Basic Power Distribution Units Customer presentation

HP Basic Power Distribution Units Customer presentation David Chetham-Strode WW Product Manager HP Enterprise Infrastructure Solutions © Copyright 201...
Author: June Morton
12 downloads 0 Views 1MB Size
HP Basic Power Distribution Units Customer presentation David Chetham-Strode WW Product Manager HP Enterprise Infrastructure Solutions © Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Get back to basics

Back to basics: stressing simplicity and adherence to fundamental principles

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Table of contents • • • • • • • • •

3

What is announcing HP Basic Power Distribution Units What’s new? Transition information Product features Model description and part number Product support information Choose HP Technology Services for support HP Technology Services for ISS hardware options Contacts, tools, and resources

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

“To succeed, you will soon learn, as I did, the importance of a solid foundation in the basics …” Alan Greenspan

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – One piece design New one piece design • 1U/0U Side of rack • 3 vertical sizes for rear of rack – Half height – 22U racks and taller – Mid Height – 36U racks and taller – Full Height – 42U racks and taller

Announce March 25th, 2013 5

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Replaces HP modular PDU No more core and stick • No more extra cabling between core and sticks • No more time consuming multiple component installations

6

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Continuing modular PDU core only models

7

Part Number

Description

252663-D74

4.9kVA 24A High Voltage NA/JP Core

252663-D75

8.3kVA 40A High Voltage NA/JP Core

252663-B33

7.3kVA 32A High Voltage INTL Core

252663-B34

9.2kVA 40A High Voltage INTL Core

AF511A

17.3kVA 48A Three Phase NA/JP Core

AF512A

8.6kVA 24A Three Phase NA/JP Core

AF513A

11kVA 16A Three Phase INTL Core

AF518A

22kVA 32A Three Phase INTL Core

AF519A

14.4kVA 40A Three Phase NA/JP Core

AF500A

HP Two C13 PDU Extension Bar (pair)

351655-B21

HP Fixed Cord Extension Bars (pair)

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

4-6 x C19

HP Basic PDU – Tool less mounting Tool less mounting on vertical models • Industry standard Button and Keyhole mounting • Drops in to HP Intelligent Series and many 3rd party racks • CTO compatible

8

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Flexible mounting Multiple mounting options • Fits many 3rd party racks • Mounts on left or right side of rack • Rear facing outlets – Maintains keep out zone completely! • Mounts cable up or cable down

9

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Flexible mounting Multiple mounting options • Side facing outlets – Allows for 2 vertical PDUs on same side of rack – Up to 4 half height PDUs on one side of 42U or 47U rack • Outlet area maintains keep out zone • Breaker box extends into keep out zone

CTO Bracket 10

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Flexible mounting Multiple mounting options • • • •

11

1U in any EIA standard rack Zero U side of rack mounting in HP racks Mounts front an back for 2 PDUs in the same Rack space No Extension bars required!

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – 1U/0U models All racks 1.9kVA 120V L5-20 input (H5M54A NA/JPN)

12 x NEMA 5-20

3.6kVA 200-240V C20 input (H5M56A WW)

12 x C13 12

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Half height models NA/JPN 22U and taller racks

H5M55A 120V L5-30 input (NA/JPN)

18 x NEMA 5-20 H5M58A 208V L6-30 input (NA/JPN)

20 x C13 H5M61A 208V 3 Phase L15-30 input (NA/JPN)

18 x C13 Up to 4 per side in a 42U or 47U rack! 13

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Half height models INTL/WW 22U and taller racks 3.6kVA 200-240V C20 input (H5M57A WW)

20 x C13

7.3kVA 220-240V 32A input (H5M68A INTL)

20 x C13 14

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Mid height models NA/JPN 36U and taller racks 4.9kVA 208V L6-30 Input (H5M59A NA/JPN) 24 x C13 + 6 x C19 8.3kVA 208V CS8265C Input (H5M60A NA/JPN) 30 x C13 + 6 x C19

8.6kVA 208V 3 Phase L15-30 Input (H5M62A NA/JPN) 30 x C13 + 6 x C19 15

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Mid height models NA/JPN 36U and taller racks New Dual Voltage models provide high and low voltage outlets! 5.7kVA 208V 3 Phase L21-20 Input (H5M63A NA/JPN)

24 x C13 + 3 x NEMA 5-20

8.6kVA 208V 3 Phase L21-30 Input (H5M64A NA/JPN) 24 x C13 + 3 x C19 = 3 x NEMA 5-20

16

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Mid height models INTL/WW 36U and taller racks 7.3kVA 220-240V IEC 32A input (H5M70A INTL) 24 x C13 + 6 x C19 10kVA 200-240V IEC 63A input (H5M71A INTL) 30 x C13 + 6 x C19 10kVA 200-240V Hardwired input (H5M75A WW) 30 x C13 + 6 x C19 11kVA 380-400 IEC 16A 3 Phase input (H5M72A INTL) 24 x C13 + 6 x C19 17

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – Full height models 42U and taller racks

12.4kVA 208V 3 Phase 50A input (H5M65A NA)/16.6kVA 400V 3 Phase 30A input (H5M67A NA) 36 x C13 + 6 x C19 11kVA 400V 3 Phase16A input (H5M73A INTL) 36 x C13 + 6 x C19

18

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – 480 Volt specialty models 480 Volt 3 Phase in = 277 Volt single phase out • • • • • •

Rong Feng LS-26 Outlets rated for 277 Volts 13.2kVA , 15 outlet Half Height 19.9kVA, 30 outlet Full Height IEC 30A 5 wire input plugs on both Industry standard button and keyhole mounting Rear facing outlets only

Note: 480V models available in North America only

19

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Rong Feng 203P Outlets (LS-26)

HP Basic PDU – 480 Volt Accessories 277 Volt specific cables, power supplies, and accessories

Rong Feng 203 Connector (LS-25)

• 1200 Watt Common Slot 277 VAC Hot Plug Power Supply – 94% efficiency • 2.5ft and 4.5ft 277V Jumper cables • 277V to 230V Rack Mount Transformer – 800VA/720 Watts output – 2U Rack mount – For non-277V compatible components

20

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

LS-25

LS-26

HP Basic PDU – HP advantages 3 year warranty • Automatic CarePack coverage – ProLiant CarePacks in the same rack cover all PDUs and Rack options • Optimized for HP Racks and compatible with many 3rd party racks • Maintains Keep Out Zone in HP Racks – Does not interfere with rear maintenance in the rack

21

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Contacts • • • • •

22

WW: David Chetham-Strode, [email protected] Americas: Maryam Chaudry, [email protected] EMEA: Stefanie Hansel, [email protected] Asia Pacific: Freesia Ser, [email protected] Japan: Jihon Murakami, [email protected]

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Thank you

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Back up

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Modular PDU to HP Basic PDU – Transition chart Discontinued Modular PDU Part Number 252663-D71

252663-D72 252663-D73 252663-B31 252663-B32 252663-B24 252663-B21

25

New Basic PDU Part Number

New Description

Amperage

Inlet Plug

Form

H5M54A

HP 1.9KVA 120V 12out NA/JP bPDU

20A

L5-20

1U/0U

12

H5M55A

HP 2.8kVA 120V 18out NA/JP bPDU

30A

L5-30

Half Height

18

H5M58A

HP 4.9kVA 208V 20out NA/JP bPDU

30A

L6-30

Half Height

20

H5M59A

HP 4.9kVA 208V 30out NA/JP bPDU

30A

L6-30

Mid Height

24

6

H5M60A

HP 8.3kVA 208V 36out NA/JP bPDU

50A

CS8265C

Mid Height

30

6

H5M68A

HP 7.3kVA 230V 20out INTL bPDU

32A

IEC 32A 3 wire

Half Height

20

H5M70A

HP 7.3kVA 230V 30out INTL bPDU

32A

IEC 32A 3 wire

Mid Height

24

6

H5M71A

HP 10kVA 230V 36out INTL bPDU

45A

IEC 63A 3 wire

Mid Height

30

6

H5M56A

HP 3.6kVA 200-240V 12out WW bPDU

16A

IEC C20

1U/0U

10

H5M57A

HP 3.6kVA 200-240V 20out WW bPDU

16A

IEC C20

Half Height

20

H5M75A

HP Hrdwrd 200-240V 36out WW bPDU

Up to 40A

Hardwire

Mid Height

30

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

C13

C19

6

5-20

HP Basic PDU – North America/Japan Part Number

Description

Voltage

Amperage

Inlet Plug

Form

H5M54A

HP 1.9KVA 120V 12out NA/JP bPDU

100-120V

20A

L5-20

1U/0U

12

H5M55A

HP 2.8kVA 120V 18out NA/JP bPDU

100-120V

30A

L5-30

Half Height

18

H5M58A

HP 4.9kVA 208V 20out NA/JP bPDU

200-208V

30A

L6-30

Half Height

20

H5M59A

HP 4.9kVA 208V 30out NA/JP bPDU

200-208V

30A

L6-30

Mid Height

24

6

H5M60A

HP 8.3kVA 208V 36out NA/JP bPDU

200-208V

50A

CS8265C

Mid Height

30

6

H5M61A

HP 8.6kVA 208V 3Ph 18out NA/JP bPDU

200-208v

30A 3Ph

L15-30

Half Height

18

H5M62A

HP 8.6kVA 208V 3Ph 30out NA/JP bPDU

200-208v

30A 3Ph

L15-30

Mid Height

24

H5M63A

HP 5.7kVA 208V 3Ph 27out NA/JP DV bPDU

200-208v

20A 3Ph

L21-20

Mid Height

24

H5M64A

HP 8.6kVA 208V 3Ph 30out NA/JP DV bPDU

200-208v

30A 3Ph

L21-30

Mid Height

24

3

H5M65A

HP 12.4kVA 208V 3Ph 42out NA/JP bPDU

200-208V

50A 3Ph

CS8365C

Full Height

36

6

H5M67A

HP 16.6kVA 400V 3Ph 42out NA bPDU

380-415V

30A 3Ph

IEC 30A 5 wire

Full Height

36

6

26

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

C13

C19

5-20

6 3 3

HP Basic PDU – International and world wide Part Number

Description

Voltage

Amperage

Inlet Plug

Form

H5M68A

HP 7.3kVA 230V 20out INTL bPDU

220-240V

32A

IEC 32A 3 wire

Half Height

20

H5M70A

HP 7.3kVA 230V 30out INTL bPDU

220-240V

32A

IEC 32A 3 wire

Mid Height

24

6

H5M71A

HP 10kVA 230V 36out INTL bPDU

220-240V

45A

IEC 63A 3 wire

Mid Height

30

6

H5M72A

HP 11kVA 400V 3Ph 30out INTL bPDU

380-415V

16A 3Ph

IEC 16A 5 wire

Mid Height

24

6

H5M73A

HP 11kVA 400V 3Ph 42out INTL bPDU

380-415V

16A 3Ph

IEC 16A 5 wire

Full Height

36

6

Part Number

Description

Voltage

Amperage

Inlet Plug

Form

C13

C19

H5M56A

HP 3.6kVA 200-240V 12out WW bPDU

200-240V

16A

IEC C20

1U/0U

10

H5M57A

HP 3.6kVA 200-240V 20out WW bPDU

200-240V

16A

IEC C20

Half Height

20

H5M75A

HP Hrdwrd 200-240V 36out WW bPDU

200-240V

Up to 40A

Hardwire

Mid Height

30

27

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

C13

C19

6

HP Basic PDU – NA/JPN marketing names Region

Part Number

Marketing Name

NA/JP

H5M54A

HP 1.9kVA 120 Volt 12 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M55A

HP 2.8kVA 120 Volt 18 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M58A

HP 4.9kVA 208 Volt 20 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M59A

HP 4.9kVA 208 Volt 30 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M60A

HP 8.3kVA 208 Volt 36 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M61A

HP 8.6kVA 208 Volt Three Phase 18 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M62A

HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Basic Power Distribution Unit

NA/JP

H5M63A

HP 5.7kVA 208 Volt Three Phase 27 Outlet NA/JP Dual Voltage Basic Power Distribution Unit

NA/JP

H5M64A

HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Dual Voltage Basic Power Distribution Unit

NA/JP

H5M65A

HP 12.4kVA 208 Volt Three Phase 42 Outlet NA/JP Basic Power Distribution Unit

NA

H5M67A

HP 16.6KVA 400 Volt Three Phase 42 Outlet NA Basic Power Distribution Unit

NA

H3X07A

HP 13.2kVA 480 Volt Three Phase 15 Outlet NA Basic Power Distribution

NA

H3X08A

HP 19.9kVA 480 Volt Three Phase 30 Outlet NA Basic Power Distribution

NA

H3X09A

HP 800VA - 277V Input/230V Output NA Rack Mount Transformer

28

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Basic PDU – INTL and WW marketing names Region

Part Number

Marketing Name

INTL

H5M68A

HP 7.3kVA 230 Volt 20 Outlet INTL Basic Power Distribution Unit

INTL

H5M70A

HP 7.3kVA 230 Volt 30 Outlet INTL Basic Power Distribution Unit

INTL

H5M71A

HP 10kVA 230 Volt 36 Outlet INTL Basic Power Distribution Unit

INTL

H5M72A

HP 11kVA 400 Volt Three Phase 30 Outlet INTL Basic Power Distribution Unit

INTL

H5M73A

HP 11kVA 400 Volt Three Phase 42 Outlet INTL Basic Power Distribution Unit

Region

Part Number

Marketing Name

WW

H5M56A

HP 3.6kVA 200-240 Volt 12 Outlet WW Basic Power Distribution Unit

WW

H5M57A

HP 3.6kVA 200-240 Volt 20 Outlet WW Basic Power Distribution Unit

WW

H5M75A

HP Hardwired 200-240 Volt 36 Outlet WW Basic Power Distribution Unit

29

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.