Hoval Modul-plus Calorifier Modul-plus Description
Subject to alterations
Hoval Calorifier Modul-plus • • •
•
Calorifier out of stainless steel 1.4401 Heating water shell made of steel Thermic insulation - calorifier body with 50mm mineral wool mat and fiber glass texture - Front plates with polyurethan plastic heat insulation - Casing incl. bottom insulated with 50mm glas wool mat Casing made of steel plates, red/orange powder coated
Optional • Loading pump • Walkable casing • Flow temperatur 110°C • Butt-welded • Butt-welded with magnesium anode
Delivery • Calorifier and casing separately packed
Calorifier control panel Type EK 105-90 • • • • •
For mounting on the calorifier Thermometer Temperature controller 40 - 80°C Temperature limiter 90°C For max. working temperature 90°C
Type EK 105/Z-90 •
2 Temperature controller
Type EK 106-110 • • • • •
For mounting on the calorifier Thermometer Temperature controller 40 - 80°C Temperature limiter 90°C For max. working temperature 110°C
Model F 21 F 31 F 41 F 51 F 32 F 42 F 52
Typ EK 106/Z-110 •
2 Temperature controller
2
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Calorifier out of stainless steel 1.4401 and heating water shells made of steel Delivery Calorifier and casing separately packed Design: Working pressure hot water 6 bar heating 5 bar, flow temperatur 90°C Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
F31
1615
113,9 148,5 187,2
17 20 25
8000 286
8000 287 8000 288
F41
1800
136,3 213,6 250,2
30 40 45
F51
2160
199,4 268,6 321,5
45 70 80
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
F42
1800
227,6 354,0 427,3
100 >100 >100
8000 291
F52
2160
398,8 537,2 634,8
>100 >100 >100
8000 292
1
2
8000 289
8000 290
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
3
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Design: Working pressure hot water 6 bar, heating 5 bar, flow temperature 90°C, butt-welded Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
8000 272
F31
1615
113,9 148,5 187,2
17 20 25
8000 273
F41
1800
136,3 213,6 250,2
30 40 45
8000 274
F51
2160
199,4 268,6 321,5
45 70 80
8000 275
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
F42
1800
227,6 354,0 427,3
100 >100 >100
8000 277
F52
2160
398,8 537,2 634,8
>100 >100 >100
8000 278
1
2
8000 276
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
Design: Working pressure hot water 10 bar, heating 8 bar, flow temperature 90°C, butt-welded Modulplus Type
Height mm
F21 F31
1615 1615
8000 265 8000 266
F41 F51
1800 2160
8000 267 8000 268
F32 F42 F52
1615 1800 2160
8000 269 8000 270 8000 271
4
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Design: Working pressure hot water 6 bar, heating 5 bar, flow temperature 90°C, butt-welded with magnesium anode Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
7000 129
F31
1615
113,9 148,5 187,2
17 20 25
7000 130
F41
1800
136,3 213,6 250,2
30 40 45
7000 132
F51
2160
199,4 268,6 321,5
45 70 80
7000 134
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
F42
1800
227,6 354,0 427,3
100 >100 >100
7000 133
F52
2160
398,8 537,2 634,8
>100 >100 >100
7000 135
1
2
7000 131
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
Design: Working pressure hot water 10 bar, heating 8 bar, flow temperature 90°C, butt welded with magnesium anode Modulplus Type
Height mm
F21 F31
1615 1615
7000 136 7000 137
F41 F51
1800 2160
7000 139 7000 141
F32 F42 F52
1615 1800 2160
7000 138 7000 140 7000 142
5
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Design: Working pressure hot water 6 bar, heating 5 bar, flow temperature 110°C Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
7000 101
F31
1615
113,9 148,5 187,2
17 20 25
7000 102
F41
1800
136,3 213,6 250,2
30 40 45
7000 104
F51
2160
199,4 268,6 321,5
45 70 80
7000 106
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
7000 103
F42
1800
227,6 354,0 427,3
100 >100 >100
7000 105
F52
2160
398,8 537,2 634,8
>100 >100 >100
7000 107
1
2
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
6
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Design: Working pressure hot water 6 bar, heating 5 bar, Flow temperature 110°C, butt-welded Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
7000 115
F31
1615
113,9 148,5 187,2
17 20 25
7000 116
F41
1800
136,3 213,6 250,2
30 40 45
7000 118
F51
2160
199,4 268,6 321,5
45 70 80
7000 120
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
F42
1800
227,6 354,0 427,3
100 >100 >100
7000 119
F52
2160
398,8 537,2 634,8
>100 >100 >100
7000 121
1
2
7000 117
-
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
Design: Working pressure hot water 10 bar heating 8 bar, flow temperatur 110°C, butt-welded Modulplus Type
Height mm
F21 F31
1615 1615
7000 122 7000 123
F41 F51
1800 2160
7000 125 7000 127
F32 F42 F52
1615 1800 2160
7000 124 7000 126 7000 128
7
Hoval Modul-plus Price Subject to alterations
Calorifier Modul-plus
Part no.
Design: Working pressure hot water 6 bar heating 5 bar, Flow temperature 110°C, butt-welded with magnesium anode Modulplus Type
Height mm
kW1
Flates2
F21
1615
76,5 115,5
9 12
7000 143
F31
1615
113,9 148,5 187,2
17 20 25
7000 144
F41
1800
136,3 213,6 250,2
30 40 45
7000 146
F51
2160
199,4 268,6 321,5
45 70 80
7000 148
F32
1615
227,9 297,0 329,6 374,4
60 75 80 90
F42
1800
227,6 354,0 427,3
100 >100 >100
7000 147
F52
2160
398,8 537,2 634,8
>100 >100 >100
7000 149
1
2
7000 145
kW = output at 45/10°C, Flow temperature 80 °C Flates = Quantity of flates which can be supplied with the calorifier (according Procalguideline).
Design: Working pressure hot water 10 bar heating 8 bar, flow temperature 110°C, butt welded with magnesium anode Modulplus Type
Height mm
F21 F31
1615 1615
7000 150 7000 151
F41 F51
1800 2160
7000 153 7000 155
F32 F42 F52
1615 1800 2160
7000 152 7000 154 7000 156
8
Hoval Modul-plus Price Subject to alterations Part no. Walkable casing F31, F51 F21, F41 F42 F32, F52
627 627 627 627
988 987 990 989
686 687 686 687
677 214 678 304
Control panel For mounting on the modul plus. With thermometer and temperature controller 40-80°C. Design 110°C with temperature limiter 95°C. Type «Z» with additional temperature controller.
Type EK EK EK EK
Working temperatute heating
105-90 105/Z-90 106-110 106/Z-110
90°C 90°C 110°C 110°C
Accessories Loading pump Biral Prices with out counter flange Working pressure 6 bar, 3 x 230 V 50/60 Hz, 3 x 400 V 50/60 Hz In the case of an order, please advice every time type of the pump with the required voltage. Pump Type
DN
Modul-plus Type
LX 323 LX 402
R 2’’ 40
F21
LX 323 LX 402 LX 654
R 2’’ 40 65
F31
LX 323 LX 503 LX 654
R 2’’ 50 65
F41
LX 323 LX 504 L 804
R 2’’ 50 80
F51
LX 401 LX 653 LX 654 L 804
40 65 65 80
F32
LX 401 LX 653 LX 654
40 65 65
F42
LX 402 LX 654 L 804
40 65 80
F52
All pumps also available with 1 ph x 230V 50 or 60 Hz (on request).
2
Hoval Modul-plus Technical data Subject to alterations
Modul-plus Type
F 21
F 31
F 41
F 51
F 32
F 42
F 52
2
3
4
5
6
8
10
230 2,84 80 1,4 495
345 4,26 80 2,4 495
460 5,68 80 3 540
575 7,1 80 3,6 698
690 8,52 80 0,74 712
920 11,36 80 0,9 775
1150 14,2 80 1,1 1000
• Test pressure (6 bar) (10 bar)
bar bar bar bar
6 10 12 15
6 10 12 15
6 10 12 15
6 10 12 15
6 10 12 15
6 10 12 15
6 10 12 15
• Weight without casing version 6 bar version 10 bar • Weight casing
kg kg kg
165 205 104
215 275 104
265 345 115
315 415 140
370 490 121
470 630 135
570 770 160
Heating • Heating water volume • Heating water temperature max. • Flow resistance1
Litre °C z-Amount
30 110 2
45 110 2,8
60 110 3,6
75 110 4,7
90 110 0,78
120 110 1
150 110 1,4
bar bar bar bar
5 8 7,5 12
5 8 7,5 12
5 8 7,5 12
5 8 7,5 12
5 8 7,5 12
5 8 7,5 12
5 8 7,5 12
• Number of bottles Calorifier • Volume • Heating surface • Hot water temperature max. • Flow resistance1 • Readiness loss rated heat load2 • Working pressure
• Working pressure • Test pressure (5 bar) (8 bar) 1 2
Litre m² °C z-Amount W
Flow resistance (mbar) = Flow (m³/h)2 x z at calorifier temperature 60 °C
Flow resistance heating
Flow resistrance hot water
10
Hoval Modul-plus Technical data Subject to alterations
Hot water output at 70°C flow temperature Primary flow connection on the top of the calorifier (counter flow)
Modul- Number Voluplus of me Type bottles dm3
Heating surface m2
Loading pump Biral Type
m3/h
mWS
mbar 1
Hot water output dm3/h 3 dm3/10 min 2 45°C 60°C 45°C
kW 4
Flates 5
F21
2
230
2,84
LX323 LX402
3,5 8
1,7 2,0
25 120
434 488
640 960
1520 2120
61,8 86,2
7 11
F31
3
345
4,26
LX323 LX402 LX654
4 7 12
1,5 2,2 5,5
40 120 450
575 600 635
700 900 1200
2100 2800 3600
85,4 113,9 146,5
7 11 17
F41
4
460
5,68
LX323 LX503 LX654
4 8 10,5
1,5 3,4 5,7
55 240 440
814 900 942
1100 1700 2000
2700 4100 4850
109,8 166,8 197,3
15 28 35
F51
5
575
7,10X
LX323 LX504 LX804
4 8 12
1,5 4,3 8,1
75 300 720
1028 1137 1221
1250 1900 2400
3750 5200 6300
152,6 211,6 256,3
17 32 45
F32
6
690
8,52
LX401 LX653 LX654 LX804
8 14 18 24
1,5 3,5 4,8 7,0
45 165 300 530
1151 1200 1234 1271
1400 1800 2100 2400
4200 5600 6200 7200
170,9 227,9 252,3 293,0
20 30 38 45
F42
8
920
11,36
LX401 LX653 LX654
8 12 16
1,5 3,7 5,1
62 150 260
1628 1714 1800
2200 2800 3400
5400 6700 8200
219,7 272,6 333,7
40 50
F52
10
1150
14,20
LX402 LX654 LX804
8 16 21
2,0 4,8 7,3
82 340 610
2057 2274 2391
2500 3800 4500
7500 10400 11800
305,2 423,2 480,2
dm3/h 3 dm3/10 min 2 45°C 60°C 45°C
kW 4
Flates 5
Hot water output at 80°C flow temperature Primary flow connection on the top of the calorifier (counter flow) Modul- Number Voluplus of me Type bottles dm3
Heating surface m2
Hot water output Loading pump Biral Type m3/h mWS
mbar 1
F21
2
230
2,84
LX323 LX402
3,5 8
1,7 2,0
25 120
478 542
900 1300
1880 2840
76,5 115,5
9 12
F31
3
345
4,26
LX323 LX402 LX654
4 7 12
1,5 2,2 5,5
40 120 450
652 706 778
1350 1800 2400
2800 3650 4600
113,9 148,5 187,2
17 20 25
F41
4
460
5,68
LX323 LX503 LX654
4 8 10,5
1,5 3,4 5,7
55 240 440
907 1042 1113
1750 2700 3200
3350 5250 6150
136,3 213,6 250,2
30 40 45
F51
5
575
7,10
LX323 LX504 LX804
4 8 12
1,5 4,3 8,1
75 300 720
1187 1356 1477
2200 3200 3950
4900 6600 7900
199,4 268,6 321,5
45 70 80
8 14 18 24
1,5 3,5 4,8 7,0
45 165 300 530
1305 1413 1485 1556
2700 3600 4200 4800
5600 7300 8100 9200
227,9 297,0 329,6 374,4
60 75 80 90
F32
6
690
8,52
LX401 LX653 LX654 LX804
F42
8
920
11,36
LX401 LX653 LX654
8 12 16
1,5 3,7 5,1
62 150 260
1814 1970 2113
3500 4600 5400
6700 8700 10500
272,6 354,0 427,3
100 >100 >100
F52
10
1150
14,20
LX402 LX654 LX804
8 16 21
2,0 4,8 7,3
82 340 610
2374 2713 2877
4400 6400 7400
9800 13200 15600
398,8 537,2 634,8
>100 >100 >100
11
Hoval Modul-plus Technical data Subject to alterations
Hot water output at 90°C flow temperatur Only to be used if high outputs are demanded constantly (e.g. hotels, industry and trade) Primary flow connection on the top of the calorifier (counter flow).
Modul- Number Voluplus of me Type bottles dm3
Heating surface m2
Hot water output Loading pump Biral Redline Type
m3/h
mWS
mbar 1
dm3/10 min 2 45°C
60°C
dm3/h 3 45°C
kW 4
F21
2
230
2,84
LX323 LX402
3,5 8
1,7 2,0
25 120
550 650
1360 1960
2250 3480
91,5 141,6
F31
3
345
4,26
LX323 LX402 LX654
4 7 12
1,5 2,2 5,5
40 120 450
713 793 893
1850 2550 3300
3450 4300 5800
140,4 175,0 236,0
F41
4
460
5,68
LX323 LX503 LX654
4 8 10,5
1,5 3,4 5,7
55 240 440
978 1157 1250
2250 3500 4150
4100 6400 7500
166,8 260,4 305,2
F51
5
575
7,10
LX323 LX504 LX804
4 8 12
1,5 4,3 8,1
75 300 720
1329 1543 1692
3050 4350 5250
5650 7800 9100
229,9 317,4 370,3
F32
6
690
8,52
LX401 LX653 LX654 LX804
8 14 18 24
1,5 3,5 4,8 7,0
45 165 300 530
1426 1585 1671 1785
3700 5100 5800 6600
6900 8600 9800 11600
280,8 350,0 398,8 472,0
F42
8
920
11,36
LX401 LX653 LX654
8 12 16
1,5 3,7 5,1
62 150 260
1956 2142 2314
4500 5800 7000
8200 10400 12800
333,7 423,2 520,9
F52
10
1150
14,20
LX402 LX654 LX804
8 16 21
2,0 4,8 7,3
82 340 610
2658 3085 3316
6100 8700 10 000
11300 15600 17500
459,8 634,8 712,2
1
mbar dm3/10 min. 3 dm3/h 4 kW 2
= Flow resistance in the calorifier = Calorifier heated up to 60°C = Continuous output per hour, cold water inlet temperature 10°C. = Input required at 45°C/10°C
12
Hoval Modul-plus Dimension Subject to alterations
Type F21, F41, F42
Type F21, F41
Type F42
min. 700
b
l
1
7
b
b
180150
4
7
140
65
140
65
6 205 135 70
h
120
90
100
2
90
2 5
60
100
5
3
300
3
3 5
a
1905
Type F31, F51
Type F31, F51, F32, F52
a
2
Type F32, F52
min. 700
b
l
b
150 180
1 7
4
7
b 140
65
140
65
6 205 135 70
h
120
1 2 3 4/5
6 7
100
2 5
300
3 2
90
90
60
100
5
3
3 5
a
1905
Hot water 2" Cold water 2" Circulation 1" Heating connections F21–51 = DN 50, F32–52 = DN 65 Pos. 4 = Flow, Pos. 5 = Return Control panel Electro connections
a
2
Special flange for working pressure 8 bar DN/bar
D
k
d
50/8 65/8
140 160
110 130
14 14
dk D
Type
b
l
h
F21/1615 F31/1615 F41/1800 F51/2160
530 530 530 530
1882 1882 1882 1882
1615 1615 1800 2160
a 395 395 395 395
Type
b
l
h
F32/1615 F42/1800 F52/2160
885 885 885
1882 1882 1882
1615 1800 2160
a 790 790 790
13
Hoval Modul-plus Example Subject to alterations Scheme heating Calorifier in a heating system
Connection to longdistance heating system max. 110°C, 8 bar
3 1
2
3
3
M 6 M 5
4
4
M
4
Calorifier in substation 1 Loading pump controlled with calorifier temperature controller 2 Non return valve 3 Automatic exhauster 4 Syphon for the prevention of gravity circulation. height min. 3 x pipe diameter 5 Motorized straight through valve 6 Motorized 3 way valve
3
2 1
M
4
Scheme sanitary connection 2 calorifier parallel connected
2 3
1
2 3
2 3
1
1
1 = Cold water 2 = Hot water 3 = Circulation
14