Air Handler / Chilled Water / Electric
CWA2 “C” SERIES
Multiposition Design With Chilled Water Coil (0-20 KW) (Upflow/Horizontal Left or Horizontal Right *)
TM
F
Description:
E
The CWA2-XX chilled water air handler with electric heatseries is designed for multiposition applications in closet, attic or basement installations. The 24CWA2-XX unit handles up to 800 CFM of air movement, 1.5 to 2.0 tons of cooling and up to 10 KW of electric heat. The 36CWA2-XX unit handles up to 1200 CFM of air movement, up to 3.0 tons of cooling and up to 15KW of electric heat. The 48 CWA2-XX unit handles up to 1750 CFM of air movement, 3.0 to 4.0 ton’s of cooling and up to 20 KW of electric heat.The 60 CWA2-XX unit will move up to 2100 CFM of air, 3 to 5 tons of cooling and up to 20KW of electric heat. For cooling requirements, these units are designed with 2-pipe chilled water a-coils. These units are UL & ULc listed (Approved for Canada).
G
B
A
B AIR OTT INL OM ET D
C
Physical Dimensions Model No.
A
B
24CWA 2-XX
17 /2
21
15
17 /2
16
12 /8
393/4
36CWA 2-XX
171/2
21
15
171/2
16
125/8
393/4
48CWA 2-XX 60CWA 2-XX
21 /2
25
19 /4
22/4
19 /8
17 /4
493/4
1
1
C
D
1
E 1
1
F
5
G 5
1
Note: “-XX” indicates electric heat (KW) size.
Standard Features: Upflow, horizontal right to left and (*) easily field converted to horizontal left to right airflow without additional parts. Drain pans are plastic, thus non-rusting. Drain pans have primary and secondary drains for either Left or Right hand connections. Pre-painted (Designer Grey) front & top is the same high quality finish Cabinet durability is ensured by using a heavy Ga. galvanized steel. All units are equipped with Time Delay Relay, factory installed (standard). All units include a 1-inch throwaway filter (standard). All units are 208/240V / 1 Phase / 60 HZ. All units are shipped with a 208/240V / 40VA transformer. All units are suitable for 0 inch clearance to combustible materials. Units are not suitable for Counterflow / Downflow applications. Blower assembly slides out for easy maintenance. Chilled water coil connections are swaged and then factory sealed with copper caps to maintain a nitrogen holding charge.
Optional Extra: Factory installed Circuit Breaker on 10 KW and below models. All Technical Specifications Subject to Change Without Notice.
Page 1
Spec. CWA2-070106
For more information contact Customer Service at (817) 624-0820 or your SunTherm Representative. 501 Terminal Road Fort Worth, TX 76106 (817) 624-0820 Fax (817) 624-8581
Performance Data:
Nominal SCFM
Nominal Cooling BTUH
24CWA2-XX
800 to 900
18,000 to 24,000
36CWA2-XX
1020 to 1200
30,000 to 36,000
48CWA2-XX
1650 to 1750
36,000 to 48,000
60CWA2-XX
1980 to 2100
48,000 to 60,000
Model No.
KW Electric Heat 240V 208V 0 5 8 10 0 5 8 10 15 0 5 8 10 15 20 0 5 8 10 15 20
0 3.8 6 7.5 0 3.8 6 7.5 11.3 0 3.8 6 7.5 11.3 15 0 3.8 6 7.5 11.3 15
Min. Circuit Ampacity 240V 208V
Max. Fuse or Breaker (HACR) 240V 208V
2.1 29 44 55 3.5 30 46 56 56/26 4.0 30 46 57 53/30 57/53 6.0 32 48 59 53/32 59/53
15 30 45 60 15 30 50 60 60/30 15 30 50 60 60/30 60/60 15 35 50 60 60/35 60/60
1.9 25 39 48 3.4 27 40 49 49/23 3.9 27 41 50 46/27 50/46 5.9 29 42 52 46/29 52/46
15 25 40 50 15 30 40 50 50/30 15 25 45 50 50/30 50/50 15 30 45 60 50/30 60/50
Units with over 10KW available in circuit breaker models only (U.L. Required).
Page 2
All Technical Specifications Subject to Change Without Notice.
For more information contact Customer Service at (817) 624-0820 or your SunTherm Representative. 501 Terminal Road
■
Fort Worth, TX 76106
■
(817) 624-0820
■
Fax (817) 624-8581
Spec. CW2-011203
General Specifications: Model No.
Cooling Capacity
Blower
Nominal SCFM @.2ESP w/coil
KW
24CWA2-XX
1.5 - 2 Tons
-45
900
0-10
36CWA2-XX
2.5 - 3 Tons
-34
1200
0-15
48CWA2-XX
3 - 4 Tons
-55
1700
0-20
60CWA2-XX
5 Tons
-51
2100
0-20
Filters:
Shipping Data:
Model No.
Filter Size
24CWA2-XX
16x20x1
36CWA2-XX
20x20x1
48CWA2-XX
20x25x1
60CWA2-XX
20x25x1
Model No.
Max. Shp. Wt. w/coil
Qty. Per Truck Load
118 145 170 180
192 192 144 144
24CWA2-XX 36CWA2-XX 48CWA2-XX 60CWA2-XX
Blower Data: Airflow Tonnage Model No. 24CWA2-00 24CWA2-05 24CWA2-08 24CWA2-10 36CWA2-00 36CWA2-05 36CWA2-08 36CWA2-10 36CWA2-15 48CWA2-00 48CWA2-05 48CWA2-08 48CWA2-10 48CWA2-15 48CWA2-20 60CWA2-00 60CWA2-05 60CWA2-08 60CWA2-10 60CWA2-15 60CWA2-20
Motor @230V 1 Ph 60 Hz
DD Blower
3 Spd. Motor
Range
HP
FLA
Wheel
(Tons)
Duty
.1
.2
.3
.4
.5
1.5 - 2.0
1/4
1.7
10x6
H(2.0) M(1.5) L
Cool Cool Heat
950 850 700
900 800 660
850 740 610
790 680 550
720 610 480
2.5 - 3.0
1/3
2.8
10x7
H(3.0) M(2.5) L
Cool Cool Heat
1250 1070 900
1200 1020 870
1120 970 840
1060 920 790
1000 860 720
3.0 - 3.5
1/3
3.1
10x8
H(4.0) M(3.5) L
Cool Cool Heat
1850 1750 1150
1700 1650 1060
1650 1450 1000
1500 1330 920
1410 1180 810
3.0 - 4.0
1/3
3.1
10x8
H(5.0) M(4.0) L
Cool Cool Heat
2160 2110 2000
2100 1980 1860
2000 1810 1670
1940 1750 1340
1880 1650 1200
SCFM vs. ESP (1) (2)
Notes: (1) Based upon unit w/nominal tonnage dry coil and filter installed. (2) Use .96 as approximate SCFM correction factor for wet coil.
Page 3
All Technical Specifications Subject to Change Without Notice.
For more information contact Customer Service at (817) 624-0820 or your SunTherm Representative. 501 Terminal Road
■
Fort Worth, TX 76106
■
(817) 624-0820
■
Fax (817) 624-8581
Spec. CW2-011203
Cooling Performance Data: Multiposition Chilled Water Air Handler Model
18CWA2-XX (4-Row, “A-Coil”)
24CWA2-XX (4-Row, “A-Coil”)
Cooling Capacities @ Entering Water Temperature 800F / 670F / 450F 800F / 670F / 420F Total Sensible Total Sensible 16,000
11,500
17,600
12,200
18,400
12,520
20,430
13,400
19,860
13,150
22,060
14,140
20,560
15,730
22,600
16,600
23,570
17,000
26,140
18,100
25,680
17,900
28,530
19,140
20,600
15,700
22,700
16,500
24,400
17,300
27,000
18,400
26,800
18,300
29,850
19,650
25,200
19,800
27,650
20,900
29,400
21,600
32,500
22,900
32,300
22,900
35,900
24,400
31,400
24,800
34,350
26,000
37,150
27,300
41,000
29,000
36 CWA2-XX
41,100
29,000
45,600
(4-Row, “A-Coil”)
37,500
29,600
41,100
41,800
31,500
46,000
33,300
45,000
32,900
50,000
35,000
38,300
32,000
41,500
33,400
43,800
34,500
47,800
36,250
48CWA2-XX
48,200
36,400
53,000
(4-Row, “A-Coil”)
46,400
37,700
50,500
52,600
40,500
57,800
42,700
57,500
42,600
63,500
45,100
52,000
40,400
56,900
42,500
58,350
43,100
64,300
45,600
60CWA2-XX
63,300
45,200
70,000
(4-Row, “A-Coil”)
59,500
47,700
64,750
69,200
52,100
76,300
55,100
76,400
55,200
84,650
58,700
CFM 400
600
600
GPM
Press. Drop Water (FT-WTR)
3.0
1.8
4.5
3.9
6.0
6.8
3.5
2.4
5.0
4.8
6.5
7.9
3.0
2.2
4.5
4.7
6.0
8.2
3.5
2.9
5.0
5.8
6.5
9.6
4.0
2.1
6.0
4.6
31,000
8.0
8.1
31,150
5.0
3.3
6.5
5.4
8.0
8.1
4.5
1.2
6.0
2.2
38,500
7.5
3.3
39,500
6.0
2.2
8.0
3.8
10.0
5.8
6.5
2.8
8.5
4.6
48,100
10.5
6.9
50,000
7.0
3.2
10.0
6.3
13.0
10.5
800
1,000
1,200
1,400
1,600
1,600
2,000
Press. Drop Air (WC) 0.10”
0.18”
0.14”
0.21”
0.23”
0.28”
0.24”
0.25”
0.19”
0.27”
Note: “-XX” indicates Electric Heat (KW) Size.
Page 4
All Technical Specifications Subject to Change Without Notice.
For more information contact Customer Service at (817) 624-0820 or your SunTherm Representative. 501 Terminal Road
■
Fort Worth, TX 76106
■
(817) 624-0820
■
Fax (817) 624-8581
Spec. CW2-011203
Heating Performance Data: Multiposition Chilled Water Air Handler Model
18CWA2-XX (4-Row, “A-Coil”)
24CWA2-XX (4-Row, “A-Coil”)
36 CWA2-XX (4-Row, “A-Coil”)
48CWA2-XX (4-Row, “A-Coil”)
1400F
Hot Water Capacities @ 650 F Entering Air Temperature Entering Water Temperature 1600F 1700F
1800F
29,749
35,970
39,790
43,620
31,058
37,570
41,560
45,540
31,658
38,300
42,360
46,420
41,050
49,590
54,890
60,190
43,416
52,480
58,100
63,660
44,664
54,010
59,750
65,490
41,261
49,850
55,150
60,500
44,330
53,580
59,270
65,000
45,762
55,370
61,240
67,100
51,696
62,450
69,125
75,800
55,781
67,400
74,600
81,790
57,970
70,130
77,590
62,130
75,000
83,100
68,302
82,500
91,400
100,150
71,508
86,400
95,600
104,850
CFM 400
600
600
GPM
Press. Drop Water (FT-WTR)
3.0
1.6
4.5
3.5
6.0
6.0
3.5
2.2
5.0
4.3
6.5
7.1
3.0
2.2
4.5
4.7
6.0
8.2
3.5
2.9
5.0
5.8
85,000
6.5
9.6
91,100
4.0
2.1
6.0
4.6
8.0
8.1
73,792
89,100
98,650
108,200
78,566
94,900
105,000
115,200
81,635
98,600
109,200
81,056
97,800
108,300
88,660
107,000
118,500
130,000
93,529
112,960
125,000
137,140
800
1,000
5.0
3.3
6.5
5.4
119,700
8.0
8.1
118,850
4.5
1.2
6.0
2.2
7.5
3.3
95,992
115,850
128,300
140,750
103,596
125,100
138,500
151,900
108,411
130,950
144,945
102,300
123,600
136,800
109,120
131,900
145,950
160,000
60CWA2-XX
113,451
137,160
151,750
(4-Row, “A-Coil”)
119,350
144,170
131,285 138,037
1,200
1,400
6.0
2.2
8.0
3.8
158,960
10.0
5.8
150,000
6.5
2.8
8.5
4.6
166,350
10.5
6.9
159,590
175,000
7.0
3.2
158,650
175,580
192,500
166,850
184,600
202,400
1,600
1,600
2,000
10.0
6.3
13.0
10.5
Press. Drop Air (WC) 0.08”
0.15”
0.14”
0.21”
0.23”
0.28”
0.24”
0.25”
0.19”
0.27”
Note: “-XX” indicates Electric Heat (KW) Size.
Page 5
All Technical Specifications Subject to Change Without Notice.
For more information contact Customer Service at (817) 624-0820 or your SunTherm Representative. 501 Terminal Road
■
Fort Worth, TX 76106
■
(817) 624-0820
■
Fax (817) 624-8581
Spec. CW2-011203