Innovation “Made in Germany”: FINESTFOG high-pressure systems atomize water directly. Directly means no detours via compressed air or open water storage tanks. The control unit transports pure water at 80 bar pressure to the nozzle pipes in the humidification chamber. The nozzles atomize the water into finest aerosols capable of being rapidly taken up by the air. A leading manufacturer of air humidifiers and water purifications systems in Europe for 20 years, FINESTFOG is your single-stop supplier from on-site consultancy through planning and design to commissioning and maintenance by our own technicians.
Wood processing Electronics Performing arts Textile production Food processing
Improve manufacturing quality
Material shrinkage, quality drop-off, electrostatic charge – accompanied by machine stoppages or high wastage – are indications of insufficient air humidity. Especially in winter, heating and dry outside air tend to lower interior humidity to a worrying level. A FINESTFOG air humidification system keeps air humidity constant at about 50% relative humidity. Electrostatic charge is dissipated. Hygroscopic materials such as wood, paper and textiles can be processed more easily and precisely.
Reduce ill-health and absenteeism
Tiredness, lack of concentration, dry mucous membranes, a weakened immune system – dry inside air makes people sick. FINESTFOG air humidification binds the fine dust in the air. A controlled room climate is not only important in production areas, but also in offices, showrooms or conference rooms.
Benefits over conventional duct humidification systems
>> >> >> >> >> >> >> >> >>
o water storage in the humidification chamber N Short humidification section thanks to extremely fine atomization No secondary evaporator element required Closed water circuit Frequency-controlled high-pressure pump for minimal energy consumption Cascade connection (up to 7 stages) for high efficiency with perfect control quality Optimal hygiene through UV sterilization and periodic flushing of all pipelines No nozzle drip Fair and cost-efficient maintenance concept
H ig h per f orm ance – f inel y dosed Customized air humidity – energy-efficient and easy on the environment.
The FINESTFOG single-medium nozzle is the heart of every F INESTFOG system. Crafted from high-quality stainless steel and hand finished, each nozzle is engraved to identify it as designed and produced exclusively by FINESTFOG. Nozzles in four sizes can be matched to meet the required humidification performance, allowing the system in the humidification chamber to be precisely tailored. The short humidification section keeps the proportion of condensate low – a secondary evaporator is not required; but a drop separator has to be provided.
1
2
The system is sparing in the use of water and its low power consumption protects the environment. In one hour of continuous operation a FINESTFOG control unit pressurizes 100 to 800 l of water – at an energy consumption of 0.5 kW to a maximum of 3.5 kW.
Water connection ½'' inside thread with stopcock Water inlet filter
3
Water softening system
4
Salt container
5
Wastewater connection
6
Reverse osmosis system
7
Pressure tank
8
High-pressure air humidification
9
Solenoid valve – humidification
10
Solenoid valve – pressure relief and flushing
11
High-pressure pipeline stage 1 – 3
12
Nozzle holders
13
Drop separator (to be provided on site)
155 cm
155 cm
6 7
3 1
2
4
5
50 cm
50 cm
40 cm
40 cm
80 cm
80 cm
40 cm
40 cm
E x tensi ve ex perience in hyg iene sa f e t y Healthy air humidity – immediately and for good.
The FINESTFOG hygiene concept for duct humidification is unique. It builds on the years of experience FINESTFOG has accumulated in room humidification.
GBA GESELLSCHAFT FÜR BIOANALYTIK HAMBURG MBH GESCHÄFTSBEREICH: UMWELTANALYTIK STANDORT: FREIBERG
These systems have been awarded the “Optimized Air Humidification” certification mark by the DGUV and relevant trade associations.
GBA
GBA GESELLSCHAFT FÜR BIOANALYTIK HAMBURG MBH Meißner Ring 3 • 09599 Freiberg
Geprüfte Hygiene
FINESTFOG duct humidifiers work on the same principle. Highly purified water from the reverse osmosis system passes a UV sterilization unit after the pressure tank. High-pressure pipelines and nozzle holders are flushed periodically to avoid standing water over any length of time. Maintenance reminders and warning indicators round off the safety concept. FINESTFOG duct humidifiers are VDE- and CE-tested, they comply with the VDI 6022 standard and have been issued with a recognized hygiene certificate by the Gesellschaft für Bioanalytik Hamburg mbH (since 2004).
Luftbefeuchtungssystem:
FINESTFOG Hochdruck Luftbefeuchter mit 70 Düsen. Gesamtbefeuchtungsleistung ca. 220 Liter pro Stunde.
Prüfbedingungen:
Das o. g. Befeuchtungssystem wird unter Praxisbedingungen in Form einer Langzeitstudie von April 2004 bis heute getestet. Dabei werden von Mitarbeitern aus unserem Labor vor Ort jeweils 3 Wasserproben entnommen. Die Proben stammen von dem eingesetzten Trinkwasser, vom Wasser nach dem Wasserfilter und vom Befeuchterwasser nach der installierten UV-Entkeimung. Die Wasserproben werden auf die mikrobiologischen Parameter Koloniezahl bei 22°C und 36°C, auf Hefen und Schimmelpilze sowie auf Legionellen untersucht. Die FINESTFOG-Befeuchtungsanlage ist in einer Textilfabrik in Chemnitz fest installiert und arbeitet dort seit Dezember 2003.
Anforderungen:
Entsprechend der Empfehlung der Berufsgenossenschaft Energie Textil Elektro Medienerzeugnisse (BG ETEM) sollte der Richtwert von 1.000 KBE pro 1 ml Befeuchterwasser nicht erreicht werden. Legionellen sollten nicht nachweisbar sein. Das eingesetzte Trinkwasser sollte hinsichtlich der mikrobiologischen Parameter den Anforderungen der Trinkwasserverordnung entsprechen.
Prüfergebnis:
Der von uns getestete FINESTFOG Hochdruck Luftbefeuchter erfüllt die gestellten Anforderungen sehr gut. Die ermittelten Koloniezahlen bei 22°C und 36°C liegen ausnahmslos weit unterhalb der Grenzwerte. Legionellen, Hefen und Schimmelpilze konnten bei keinem der zahlreichen Tests nachgewiesen werden.
i. A. W. Peter Laborleiter
Die Prüfergebnisse beziehen sich ausschließlich auf die genannten Prüfgegenstände. Ohne schriftliche Genehmigung der GBA darf der Prüfbericht nicht auszugsweise vervielfältigt werden.
Standort: Freiberg Telefon: +49 3731 36 62-21 Fax: +49 3731 36 62-24 E-Mail:
[email protected] Homepage: www.gba-hamburg.de
HypoVereinsbank BLZ: 200 300 00 Konto: 504 043 92 IBAN: DE 45 2003 0000 0050 404392 HYVEDEMM300 BIC:
USt.-Ident-Nr.: DE 118 554 138 St.-Nr.: 47/723/00196 Sitz der Gesellschaft: Hamburg Handelsregister: Hamburg HRB 42774
Geschäftsführer: Manfred Giesecke Ralf Murzen Dr. Roland Bernerth Dr. Jan-Wolgang Kaiser
Die Prüfergebnisse beziehen sich ausschließlich auf die genannten Prüfgegenstände. Ohne schriftliche Genehmigung der GBA darf der Prüfbericht nicht auszugsweise vervielfältigt werden.
Deutscher Akkreditierungs Rat
DAC-PL-0040-97-01
Standort: Freiberg Telefon: +49 3731 36 62-21 Fax: +49 3731 36 62-24 E-Mail:
[email protected] Homepage: www.gba-hamburg.de
HypoVereinsbank BLZ: 200 300 00 Konto: 504 043 92 IBAN: DE 45 2003 0000 0050 404392 HYVEDEMM300 BIC:
USt.-Ident-Nr.: DE 118 554 138 St.-Nr.: 47/723/00196 Sitz der Gesellschaft: Hamburg Handelsregister: Hamburg HRB 42774
Geschäftsführer: Manfred Giesecke Ralf Murzen Dr. Roland Bernerth Dr. Jan-Wolgang Kaiser
Deutscher Akkreditierungs Rat
DAC-PL-0040-97-01
13 12
8
11
9
10
Humidification chamber
5
80 cm
80 cm
5
Tap water
Drain pipe
Softened water
Pure water
T he F INEST F OG con tro l u n i t Precision control in focus.
The FINESTFOG control unit can be customized for every application. The choice ranges from a PLC and display all the way to a Siemens SPS S7 1200 with a colour Siemens Comfort touchscreen. The FINESTFOG control unit also has the capability to integrate a reverse osmosis system (below left). The F INESTFOG Premium S7 (below right) communicates with the building m anagement system and converts the input signal to a maximum 7-stage c ascade. Only high-end components are built into FINESTFOG controllers. The Comfort touchscreen gives an immediate overview of the operating state of the whole humidification system.
YEARS A H E A LT H Y INVESTMENT
F I N E S T F O G GmbH A IR + WATER
Alte Landstrasse 6 D- 85521 Ottobrunn
FON +49 (0)89 6735915-0 FAX +49 (0)89 6735915-15