Direct Burial & Water Resistant Cables Direct Burial Cable
Available Cables
Honeywell Genesis® Series Direct Burial Cables are specially designed to be buried underground. Manufactured with a more ridged jacket, these cables have a higher crush and impact resistance threshold. Our outdoor cables are not only designed to be buried but are independently tested and approved by to meet the requirements of Direct Burial and Wet Location.
• Category 5e • Audio & Speaker • Fire Alarm & Signal • Irrigation, Sprinkler & Tracer • Underground & Landscape Lighting • Type TC Mini-Split
Water Resistant Cable
Available Cables
Honeywell Genesis® Series Water Resistant Cables are manufactured with moisture absorption and water blocking technology. Applied under the jacket, super absorbent polymers, provide an extra layer of protection against damage to the cable conductors when installed in moist or wet environments.
Category 5e • Unshielded Twisted Bare Copper Pairs • Polypropylene Insulation • Linear Low-Density Polyethylene Jacket w/ Ripcord Approved for Direct Burial, Wet Location & Sunlight Resistant
AWG
# PAIRS
CATEGORY
TYPE
24
4
5e
UTP
IMPEDANCE NOM. CAP NOM. O.D. (Ohms) (pF/ft.) (in.) 100
15
AVG. WT. (lbs./Mft.)
PART #
24
5090
0.200
Audio & Speaker • Stranded Oxygen-Free Bare Copper Conductors • High Strand Count • Semi-Rigid PVC Insulation • PVC Jacket Approved for Direct Burial & Sunlight Resistant CL3/CM Listed AWG
# COND
STR COUNT
DC RESISTANCE (Ohms/Mft.)
NOM. CAP (pF/ft.)
NOM. O.D. (in.)
AVG. WT. (lbs./Mft.)
PART #
16
2
65/34
3.9
27
0.275
42
5283
16
4
65/34
4.0
21
0.350
67
5284
14
2
105/34
1.9
32
0.320
65
5285
14
4
105/34
2.5
32
0.415
110
5286
Call 1-800-222-0060 for more information.
3
Direct Burial Cables
Fire Alarm & Signal Cable (Unshielded) • Stranded Bare Copper Conductor • Semi-Rigid Polyvinyl Chloride Insulation • PVC Jacket FPL/CL2 Listed; Direct Burial approved # COND
STR/ SOL
18
2
STR
6.5
19
0.260
37
4156
18
4
STR
6.5
19
0.295
59
4157
18
6
STR
6.5
19
0.345
76
4158
18
8
STR
6.5
19
0.375
95
4159
16
2
STR
3.90
21
0.282
45
4151
14
2
STR
2.5
23
0.310
60
4153
14
4
STR
2.5
23
0.355
102
4154
AWG
DC RESISTANCE NOM. CAP NOM. O.D. AVG. WT. (Ohms/Mft.) (pF/ft.) (in.) (lbs./Mft.)
PART #
Irrigation, Sprinkler & Tracer • Commonly used as tracer wire & connecting remote control valves • Bare Copper Conductor • Polyethylene Insulation 600V Rated; Direct Burial approved # COND
STR/SOL
AVG. WT. (lbs./Mft.)
PART #
18
1
SOL
11
1301
14
1
SOL
20
1303
12
1
SOL
28
1304
Outdoor Cables
AWG
4
www.honeywellcable.com
Direct Burial Cables
Underground & Landscape Lighting • Stranded Bare Copper Conductors • Heavy Wall, Integral Zip Construction • PVC Jacket Approved for Direct Burial & Sunlight Resistant 150V Rated; ULECC AWG
# COND
NOM. O.D. (in.)
AVG. WT. (lbs./Mft.)
PART #
14
2
0.165 x 0.345
50
1021
12
2
0.165 x 0.345
82
1019
10
2
0.220 x 0.440
120
1018
8
2
0.295 x 0.590
225
1017
Type TC Mini-Split • Power + Control Tray Cable, Type TC • Stranded Bare Copper Conductors • Overall PVC Jacket w/Nylon Insulation 600V Rated, Approved for Direct Burial, Sunlight Resistant & THHN AWG
# COND
SHIELD
NOM. O.D. (in.)
PART #
14
3
Unshielded
0.365
1069
14
4
Unshielded
0.365
1070
14
5
Unshielded
0.425
1071
14
7
Unshielded
0.460
1073
Call 1-800-222-0060 for more information.
5
Water Resistant Cables
RG59/U CCTV Coaxial + Power Pair • RG59/U + 18/2 Stranded Siamese • Solid Bare Copper Coax Conductors • 18/2 Stranded Bare Copper Power Wires • 95% Bare Copper Braid • Polyethylene Jacket
STYLE
AWG
SHIELD
POWER
NOM. VP
NOM. CAP (pF/ft.)
NOM. O.D. (in.)
AVG. WT. (lbs./Mft.)
PART #
RG59/U + 18/2
20 BC
95% BC
18/2 STR
82
18
0.421 x 0.245
65
5104
RG59/U CCTV Coaxial • Solid Bare Copper Coax Conductors • 18/2 Stranded Bare Copper Power Wires • 95% Bare Copper Braid • Polyethylene Jacket
For more information: Voice: 800.222.0060 Fax: 262.947.0724 www.honeywellcable.com Automation and Control Solutions Honeywell Genesis® Series Cable 7701 95th Street Pleasant Prairie, WI 53158-2716 800.222.0060 www.honeywell.com