Genesis Series Cable. Direct Burial & Water Resistant Cables

Genesis® Series Cable Direct Burial & Water Resistant Cables Direct Burial & Water Resistant Cables Direct Burial Cable Available Cables Honeywel...
Author: Hilary Sanders
33 downloads 3 Views 522KB Size
Genesis® Series Cable

Direct Burial & Water Resistant Cables

Direct Burial & Water Resistant Cables Direct Burial Cable

Available Cables

Honeywell Genesis® Series Direct Burial Cables are specially designed to be buried underground. Manufactured with a more ridged jacket, these cables have a higher crush and impact resistance threshold. Our outdoor cables are not only designed to be buried but are independently tested and approved by to meet the requirements of Direct Burial and Wet Location.

• Category 5e •  Audio & Speaker •  Fire Alarm & Signal •  Irrigation, Sprinkler & Tracer •  Underground & Landscape Lighting •  Type TC Mini-Split

Water Resistant Cable

Available Cables

Honeywell Genesis® Series Water Resistant Cables are manufactured with moisture absorption and water blocking technology. Applied under the jacket, super absorbent polymers, provide an extra layer of protection against damage to the cable conductors when installed in moist or wet environments.

• RG59/U CCTV Coaxial + Power Pair • RG59/U CCTV Coaxial • RG6/U CATV Coaxial – QUAD Shielded Broadband • RG6/U CATV Coaxial – DUAL Shielded Broadband

2

www.honeywellcable.com

Direct Burial Cables

Category 5e •  Unshielded Twisted Bare Copper Pairs •  Polypropylene Insulation •  Linear Low-Density Polyethylene Jacket w/ Ripcord Approved for Direct Burial, Wet Location & Sunlight Resistant

AWG

# PAIRS

CATEGORY

TYPE

24

4

5e

UTP

IMPEDANCE NOM. CAP NOM. O.D. (Ohms) (pF/ft.) (in.) 100

15

AVG. WT. (lbs./Mft.)

PART #

24

5090

0.200

Audio & Speaker •  Stranded Oxygen-Free Bare Copper Conductors •  High Strand Count •  Semi-Rigid PVC Insulation •  PVC Jacket Approved for Direct Burial & Sunlight Resistant CL3/CM Listed AWG

# COND

STR COUNT

DC RESISTANCE (Ohms/Mft.)

NOM. CAP (pF/ft.)

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

16

2

65/34

3.9

27

0.275

42

5283

16

4

65/34

4.0

21

0.350

67

5284

14

2

105/34

1.9

32

0.320

65

5285

14

4

105/34

2.5

32

0.415

110

5286

Call 1-800-222-0060 for more information.

3

Direct Burial Cables

Fire Alarm & Signal Cable (Unshielded) •  Stranded Bare Copper Conductor •  Semi-Rigid Polyvinyl Chloride Insulation •  PVC Jacket   FPL/CL2 Listed; Direct Burial approved # COND

STR/ SOL

18

2

STR

6.5

19

0.260

37

4156

18

4

STR

6.5

19

0.295

59

4157

18

6

STR

6.5

19

0.345

76

4158

18

8

STR

6.5

19

0.375

95

4159

16

2

STR

3.90

21

0.282

45

4151

14

2

STR

2.5

23

0.310

60

4153

14

4

STR

2.5

23

0.355

102

4154

AWG

DC RESISTANCE NOM. CAP NOM. O.D. AVG. WT. (Ohms/Mft.) (pF/ft.) (in.) (lbs./Mft.)

PART #

Irrigation, Sprinkler & Tracer •  Commonly used as tracer wire & connecting remote control valves •  Bare Copper Conductor •  Polyethylene Insulation 600V Rated; Direct Burial approved # COND

STR/SOL

AVG. WT. (lbs./Mft.)

PART #

18

1

SOL

11

1301

14

1

SOL

20

1303

12

1

SOL

28

1304

Outdoor Cables

AWG

4

www.honeywellcable.com

Direct Burial Cables

Underground & Landscape Lighting •  Stranded Bare Copper Conductors •  Heavy Wall, Integral Zip Construction •  PVC Jacket Approved for Direct Burial & Sunlight Resistant 150V Rated; ULECC AWG

# COND

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

14

2

0.165 x 0.345

50

1021

12

2

0.165 x 0.345

82

1019

10

2

0.220 x 0.440

120

1018

8

2

0.295 x 0.590

225

1017

Type TC Mini-Split •  Power + Control Tray Cable, Type TC •  Stranded Bare Copper Conductors •  Overall PVC Jacket w/Nylon Insulation 600V Rated, Approved for Direct Burial, Sunlight Resistant & THHN AWG

# COND

SHIELD

NOM. O.D. (in.)

PART #

14

3

Unshielded

0.365

1069

14

4

Unshielded

0.365

1070

14

5

Unshielded

0.425

1071

14

7

Unshielded

0.460

1073

Call 1-800-222-0060 for more information.

5

Water Resistant Cables

RG59/U CCTV Coaxial + Power Pair •  RG59/U + 18/2 Stranded Siamese •  Solid Bare Copper Coax Conductors •  18/2 Stranded Bare Copper Power Wires •  95% Bare Copper Braid •  Polyethylene Jacket

STYLE

AWG

SHIELD

POWER

NOM. VP

NOM. CAP (pF/ft.)

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

RG59/U + 18/2

20 BC

95% BC

18/2 STR

82

18

0.421 x 0.245

65

5104

RG59/U CCTV Coaxial •  Solid Bare Copper Coax Conductors •  18/2 Stranded Bare Copper Power Wires •  95% Bare Copper Braid •  Polyethylene Jacket

6

STYLE #

AWG

SHIELD

NOM. VP

NOM. CAP (pF/ft.)

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

RG59/U

20 BC

95% BC

82

18

0.248

36

5103

www.honeywellcable.com

Water Resistant Cables

RG6/U CATV Coaxial – QUAD Shielded Broadband •  Solid Copper Covered Steel Conductors •  (2) 100% Al Foil + (2) Al Braids •  Polyethylene Jacket

STYLE #

AWG

SHIELD

NOM. VP

NOM. CAP (pF/ft.)

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

RG6/U

18 CCS

60%/40% Al

81

16

0.300

32

5106

RG6/U CATV Coaxial – DUAL Shielded Broadband •  Solid Copper Covered Steel Conductors •  100% Al Foil + Al Braid •  Polyethylene Jacket •  Sweep Frequency: 1GHz •  Tested to Wet Location Standards

STYLE

AWG

SHIELD

SWEEP FREQ.

NOM. VP

NOM. CAP (pF/ft.)

NOM. O.D. (in.)

AVG. WT. (lbs./Mft.)

PART #

RG6/U

18 CCS

60% Al

1 GHz

82

16

0.275

32

5105

Call 1-800-222-0060 for more information.

7

For more information: Voice: 800.222.0060 Fax: 262.947.0724 www.honeywellcable.com Automation and Control Solutions Honeywell Genesis® Series Cable 7701 95th Street Pleasant Prairie, WI 53158-2716 800.222.0060 www.honeywell.com

L/OTDRCABB/D January 2014 © 2014 Honeywell International Inc.