GENERATOR DOCKING STATIONS

GENERATOR DOCKING STATIONS GENERATOR CONNECTION SYSTEM DOCKING STATIONS 4 5 3 1 1 Portable Generator 2 4/0 Feeder Cable 3 Generator Dockin...
Author: Richard Gordon
48 downloads 0 Views 2MB Size
GENERATOR DOCKING STATIONS

GENERATOR

CONNECTION SYSTEM

DOCKING STATIONS

4 5

3 1

1

Portable Generator

2

4/0 Feeder Cable

3

Generator Docking Station

4

Transfer Switch

5

To Building Electrical Panel

2

One of the biggest stories in power distribution is a specialized power distribution box—what we at HIPOWER SYSTEMS call a generator docking stations (GDS)—that is specifically designed to be connected quickly and easily to a portable (mobile; roll-up) generator. (Note that there is no industry standard name for these devices, so we will refer to them as GDSs.) The boxes themselves are not mobile. Rather, they are stationary power distribution units hardwired into a facility’s power supply infrastructure. They offer the ultimate protection for operations where power is truly mission-critical—where the facility cannot be without

GENERATOR DOCKING STATIONS // 2

power for even a few seconds, no matter what. These units enable companies to quickly and easily bring in replacements for backup generators so they can be taken down for service or maintenance, or to act as a “backup for the backup” in the event of a power outage. Since their introduction to the market, many companies are finding other, valuable uses for GDSs that go beyond the most mission-critical operations. Unlike transfer switches, which generally connect a permanent, external standby generator to a facility’s power connection for quick switching to generator power, a GDS is mounted on the building (or placed on a nearby

pad) to create a “quick connect” link between the transfer switch or other disconnect and a mobile generator. If a facility wants or needs to obtain additional power for any reason, having a previously installed, externally mounted GDS enables them to connect a portable generator, located in a nearby alley or other external location, to the building’s disconnect via simple cam-style connections. Some of these units also can incorporate male or female cam-style connections, enabling either input of power to service the building or output of power for other uses.

LEFT Generator Docking Station connections.

1

CAMLOK GUTTER PANEL 100/400A 100/400A Camlok Gutter Panel

100/400A Camlok Gutter Panel Features

• 0.090” aluminum NEMA 3R enclosure, powder-coated ANSI 61 gray.

• Aluminum, NEMA 250 Type 3R enclosure with polyurethane powder coat.

• Indoor/outdoor rated with corrosion-resistant hardware.

• Compact wall-mountable design, full CAD drawing available upon request.

• Main swing door with 1/4 turn padlockable latch. • Easy-to-remove gland plate to access permanent connection lugs. • One set of male or female 400A 16 Series stud-type, panel-mount Camlok devices. • Color-coded snap-back covers. • Electrical color code can be ordered to match any low voltage configuration.

• 100 percent ground of phase size. • For use as a quick connection port to permanently installed switch gear or other similar electrical equipment such as automatic transfer switches, manual transfer switches, double-throw safety switches, UPS systems, interlocked switch boards or bolt switches. • Can be used as a quick connection port or junction point to access and service a stationary generator.

Overall dimensions* • 16.25”W x 8.125”D x 8.125”H (Approximately 20 lbs.)

*All measurements are approximate and for estimation purposes only.

Specifications & Standards • UL Industrial Control Panel Enclosure Listed C/UL (Canada listed).

2

Our durable Generator docking stations solutions are resistant to shock, impact, corrosion and weather

GENERATOR DOCKING STATION 400/800A

TECHNICAL DATA KVA

Primary

Secondary

Amps

-

120Y208V

120Y208V

100/400A

Main No

-

277Y480V

277Y480V

100/400A

No

-

347Y600V

347Y600V

100/400A

No

2

GENERATOR DOCKING STATION 400/800A 400/800A Generator Docking Station

400/800A Generator Docking Station Features

• 0.090” aluminum NEMA 3R enclosure, powder-coated ANSI 61 gray.

• Aluminum, NEMA 250 Type 3R enclosure with polyurethane powder coat.

• Indoor/outdoor rated with corrosion-resistant hardware.

• Corrosion-resistant material designed for industrial and harsh environments.

• Main swing door with 1/4 turn padlockable latch. • Easy-to-remove gland plate to access permanent connection lugs. • Up to two sets of male or female 400A 16 Series stud-type, panel-mount Camlok devices. • Color-coded snap-back covers. • Electrical color code can be ordered to match any low voltage configuration.

Overall dimensions* • 19.0”W x 15.125”D x 30.0”H + 24.0” with leg kit (Approximate 90lbs) *All measurements are approximate and for estimation purposes only.

Specifications & Standards • UL Industrial Control Panel Enclosure Listed C/UL (Canada listed).

GENERATOR DOCKING STATIONS // 4

• Listed and labeled as defined in NFPA 70, marked for intended application. • For use as a quick connection port to permanently installed switch gear or other similar electrical equipment such as automatic transfer switches, manual transfer switches, double-throw safety switches, UPS systems, interlocked switch boards or bolt switches.

CAMLOK GUTTER PANEL 100/400A

• Can be used as a quick connection port or junction point to access and service a stationary generator.

1

TECHNICAL DATA KVA

Primary

Secondary

Amps

Main

-

120Y208V

120Y208V

400/800A

No

-

277Y480V

277Y480V

400/800A

No

-

347Y600V

347Y600V

400/800A

No

GENERATOR DOCKING STATION 1200/3200A

Available in both wall-mount and pad-mount styles. An array of accessories completes the package.

3

GENERATOR DOCKING STATION 600/800A 600/800A Generator Docking Station

600/800A Generator Docking Station Panel Features

• 0.090” aluminum NEMA 3R enclosure, powder-coated ANSI 61 gray.

• Aluminum, NEMA 250 Type 3R enclosure with polyurethane powder coat.

• Indoor/outdoor rated with corrosion-resistant hardware.

• Corrosion-resistant material designed for industrial and harsh environments.

• Padlockable main door with two 1/4 turn latches. • Easy-to-remove gland plate to access permanent connection lugs. • Two sets of male 400A 16 Series Camloks with color-coded snap covers. • Camlok color code can be ordered to match any low voltage configuration.

GENERATOR DOCKING STATION 600/800A

• Bottom-access cable trap system with rodent trap door.

Overall dimensions* • 19.0”W x 15.125”D x 30.0”H (Approximately 90 lbs.) *All measurements are approximate and for estimation purposes only.

Specifications & Standards

4

• UL Industrial Control Panel Enclosure Listed C/UL (Canada listed).

3

4

• Listed and labeled as defined in NFPA 70, marked for intended application. • For use as a quick connection port to permanently installed switch gear or other similar electrical equipment such as automatic transfer switches, manual transfer switches, double-throw safety switches, UPS systems, interlocked switch boards or bolt switches. • Can be used as a quick connection port or junction point to access and service a stationary generator. TECHNICAL DATA KVA

Primary

Secondary

Amps

-

120Y208V

120Y208V

600/800A

Main No

-

277Y480V

277Y480V

600/800A

No

-

347Y600V

347Y600V

600/800A

No

GENERATOR DOCKING STATION 1200/3200A 1200/3200A Generator Docking Station

1200/3200A Generator Docking Station Features

• 0.090” aluminum NEMA 3R enclosure, powder-coated ANSI 61 gray.

• Aluminum, NEMA 250 Type 3R enclosure with polyurethane powder coat.

• Indoor/outdoor rated with corrosion-resistant hardware.

• Corrosion-resistant material designed for industrial and harsh environments.

• Main swing door with 1/4 turn padlockable latch. • Easy-to-remove gland plate to access permanent connection lugs. • Ten sets of male 400A 16 Series Camloks with color-coded snap covers. • Camlok color code can be ordered to match any low voltage configuration. • Optional stainless steel leg kit for pad-mount applications.

• Listed and labeled as defined in NFPA 70, marked for intended application. • For use as a quick connection port to permanently installed switch gear or other similar electrical equipment such as automatic transfer switches, manual transfer switches, double-throw safety switches, UPS systems, interlocked switch boards or bolt switches. • Can be used as a quick connection port or junction point to access and service a stationary generator.

Overall dimensions* • 38.0”W x 19.25”D x 43.0”H (Approximately 318 lbs.) *All measurements are approximate and for estimation purposes only.

Specifications & Standards • UL Industrial Control Panel Enclosure Listed C/UL (Canada listed).

GENERATOR DOCKING STATIONS // 6

TECHNICAL DATA KVA

Primary

Secondary

Amps

-

120Y208V

120Y208V

1200A/3200A

Main No

-

277Y480V

277Y480V

1200A/3200A

No

-

347Y600V

347Y600V

1200A/3200A

No

MADE IN THE USA Beyond its extensive selection of quality power distribution products and assembles, HIPOWER SYSTEMS prides itself on being a complete provider in every way. We continually explore new technologies and solutions to bring power innovations to market. We stringently monitor

our design, engineering and manufacturing processes and those of our suppliers to ensure product excellence. We also focus intently on providing the highest levels of customer service and satisfaction, because we value and honor the faith you place in our company.

Made in the USA

www.hipowersystems.com

HIMOINSA POWER SYSTEMS, INC. 16002 West 110th Street, Lenexa, KS 66219-1312 Tel: 913 495 5557 | Fax: 913 495 5575 www. hipowersystems.com