General Catalogue Aluminum Bracket System EUROPEAN UNION EUROPEAN REGIONAL DVELOPMENT FUND

General Catalogue Aluminum Bracket System EUROPEAN UNION EUROPEAN REGIONAL DVELOPMENT FUND CONTENTS BSP Bracket System Polska ........................
Author: Della Edwards
2 downloads 0 Views 4MB Size
General Catalogue Aluminum Bracket System

EUROPEAN UNION EUROPEAN REGIONAL DVELOPMENT FUND

CONTENTS BSP Bracket System Polska ................................................................................................................. 3 PRODUCTS Fixing systems for curtain walls ...................................................................................................... 4 Bracket BSP Type K1/Fix .............................................................................................................................. 5 Bracket BSP Type K1/Los ............................................................................................................................ 6 Bracket BSP Type K2/Fix .............................................................................................................................. 7 bracket BSP Type K2/Los ............................................................................................................................ 8 Extruded aluminum brackets - examples of applications ......................................................... 9 Fixing systems for ventilated façades ...................................................................................... 10 Advantages of ventilated façades ...................................................................................................... 11 Bracket BSP Type KW1/A-B-Fix-Los ..................................................................................................... 12 Bracket BSP Type KW3/A-B-Fix-Los ..................................................................................................... 13 Adjustment of BSP aluminum substructure .................................................................................. 14 Extension piece BSP Type KWP1/A-B ................................................................................................ 15 Foot BSP Type KWW1/A-B ....................................................................................................................... 16 Support BSP Type KWP2/A-B ..................................................................................................................16 Profile BSP Type KWR1 .............................................................................................................................. 17 Profile BSP Type KWR2 .............................................................................................................................. 17 Profile BSP Type KWR3 .............................................................................................................................. 18 Profile BSP Type KWR4 .............................................................................................................................. 18 Hanging brackets system (horizontal rail) ...................................................................................... 19 Profile BSP Type KWRW ............................................................................................................................ 19

Aluminum Bracket System

Bracket systems for interior cladding ...................................................................................... 20 Bracket BSP Type KW1/40-A-Fix/Los .................................................................................................. 20 Profile BSP Type KWR5 .............................................................................................................................. 20 Floor to Floor BSP System ................................................................................................................. 21 Profile BSP Type KWR6 .............................................................................................................................. 21 Sections and models ................................................................................................................................. 22 Additional substructure elements ............................................................................................. 23 Bracket for timber framework BSP Type KWD/A-B ..................................................................... 23 “Y” type profile for aluminum composite panels BSP type KWRY ....................................... 23 Omega BSP profile Type RW2 ............................................................................................................... 24 Profile BSP Type KWRK .............................................................................................................................. 24 System “BSP Solar” for solar panels fixing on façades ..................................................... 25 Decorative profiles ................................................................................................................................ 26 Outward angle profile BSP Type KWN1 ............................................................................................ 26 Inlet angle profile BSP Type KWN2 ..................................................................................................... 26 Joint profile BSP Type KWF1 .................................................................................................................. 26 EXAMPLES AND CALCULATION Aluminum substructure BSP - examples of applications ........................................................ 27 Horizontal brackets BSP - examples of applications ................................................................. 27 Exemplary assembly scheme ................................................................................................................ 28 Examples of substructure layout ......................................................................................................... 29 Example of calculation ............................................................................................................................. 29 Heat transfer reduction ............................................................................................................................ 30 Examples of thermal calculations ....................................................................................................... 30 Additional services ................................................................................................................................ 31 REFERENCES Excerpt from reference list ..................................................................................................................... 32 Photographs of selected objects ........................................................................................................ 34

BSP Bracket System Polska Ltd has designed and developed the system of brackets for façade cladding. The BSP registered trademark and the BSP bracket system are protected by law. Copying and publishing without permission is prohibited by law. 2

www.bspsystem.com

ABOUT US BSP Bracket System Polska

B

SP Bracket System Polska Ltd delivers a complete bracket system for façades. We focus on quality, innovation and constant improvement to obtain the

final goal which is to satisfy the needs of all market players ranging from architects, cladding material manufacturers, to contractors to and installation companies. We offer years of experience, in-depth knowledge of the building market and a complete range of solutions meeting every need and application, when it comes to building façades. Our entrepreneurial spirit stands for continuous development. Our success is based upon our ability to think beyond boundaries, which enables us to discover opportunities resulting in new perspectives for our customers. Our staff consists of experienced and recognized experts in the area of engineering, construction management processes, investments, design, project implementations, financing and tech-

Aluminum Bracket System

nical support and works coordinations. System BSP is recommended by a world leader in façade materials - EQUITONE (former Euronit).

www.bspsystem.com

3

PRODUCTS Fixing systems for curtain walls

B

SP extruded aluminum brackets are designed to fix aluminum curtain wall façades. Optimally designed brackets allow for the transfer of all loads, from the construction of the façade to the

main load-bearing structures of the building. BSP bracket system enables to position the cladding panels in a precisemanner, so to adjust them in three directions without the need to use leveling pads. Advantages of extruded aluminum brackets BSP for curtain wall façades: Resistance to weather, especially when compared with steel brackets.



Light weight important for the cost of transportation.



Possibility of drilling additional holes or cuttings without the need for special anticorrosion treatment.



No galvanic corrosion at the interface with other elements of aluminum.



No welded joints and the risks of improper welding work.



Lack of internal stress, characteristic of consoles, bent or welded.



Optionally brackets can be supplied as a powder coated or anodized.



Reduced delivery time. Standard products available from stock.

Aluminum Bracket System



4

www.bspsystem.com

PRODUCTS Fixing systems for curtain walls Bracket BSP Typee K1/Fix

A

B

Bracket BSP Type K1/100-150-FIX

Description

100

150

Bracket BSP Type K1/100-120-FIX

100

120

Bracket BSP Type K1/100-100-FIX

100

100

Bracket BSP Type K1/100-80-FIX

100

80

Bracket BSP Type K1/120-150-FIX

120

150

Bracket BSP Type K1/120-120-FIX

120

120

Bracket BSP Type K1/120-100-FIX

120

100

Bracket BSP Type K1/120-80-FIX

120

80

Bracket BSP Type K1/200-150-FIX

200

150

Bracket BSP Type K1/200-120-FIX

200

120

Bracket BSP Type K1/200-100-FIX

200

100

Bracket BSP Type K1/200-80-FIX

200

80

Aluminum Bracket System

180 for K1/200 200 for K1/180, K1/120

www.bspsystem.com

5

PRODUCTS Fixing systems for curtain walls Bracket BSP Type K1/Los

Aluminum Bracket System

180 for K1/200 200 for K1/180, K1/120

6

A

B

Bracket BSP Type K1/100-150-LOS

Description

100

150

Bracket BSP Type K1/100-120-LOS

100

120

Bracket BSP Type K1/100-100-LOS

100

100

Bracket BSP Type K1/100-80-LOS

100

80

Bracket BSP Type K1/120-150-LOS

120

150

Bracket BSP Type K1/120-120-LOS

120

120

Bracket BSP Type K1/120-100-LOS

120

100

Bracket BSP Type K1/120-80-LOS

120

80

Bracket BSP Type K1/200-150-LOS

200

150

Bracket BSP Type K1/200-120-LOS

200

120

Bracket BSP Type K1/200-100-LOS

200

100

Bracket BSP Type K1/200-80-LOS

200

80

www.bspsystem.com

PRODUCTS Fixing systems for curtain walls

A

B

Bracket BSP Type K2/100-150-FIX

Description

100

150

Bracket BSP Type K2/100-120-FIX

100

120

Bracket BSP Type K2/100-100-FIX

100

100

Bracket BSP Type K2/100-80-FIX

100

80

Bracket BSP Type K2/120-150-FIX

120

150

Bracket BSP Type K2/120-120-FIX

120

120

Bracket BSP Type K2/120-100-FIX

120

100

Bracket BSP Type K2/120-80-FIX

120

80

Bracket BSP Type K2/200-150-FIX*

200

150

Bracket BSP Type K2/200-120-FIX*

200

120

Bracket BSP Type K2/200-100-FIX*

200

100

Bracket BSP Type K2/200-80-FIX*

200

80

Aluminum Bracket System

Bracket BSP Type K2/Fix

* available soon

www.bspsystem.com

7

PRODUCTS Fixing systems for curtain walls

Aluminum Bracket System

Bracket BSP Type K2/Los

A

B

Bracket BSP Type K2/100-150-LOS

Description

100

150

Bracket BSP Type K2/100-120-LOS

100

120

Bracket BSP Type K2/100-100-LOS

100

100

Bracket BSP Type K2/100-80-LOS

100

80

Bracket BSP Type K2/120-150-LOS

120

150

Bracket BSP Type K2/120-120-LOS

120

120

Bracket BSP Type K2/120-100-LOS

120

100

Bracket BSP Type K2/120-80-LOS

120

80

Bracket BSP Type K2/200-150-LOS*

200

150

Bracket BSP Type K2/200-120-LOS*

200

120

Bracket BSP Type K2/200-100-LOS*

200

100

Bracket BSP Type K2/200-80-LOS*

200

80

* available soon

8

www.bspsystem.com

PRODUCTS Fixing systems for curtain walls BSP extruded aluminum brackets - example of application

Aluminum Bracket System

A wide range of regulation helps to avoid problems with the tolerance of wall construction +/-20 mm

Side bracket within wall expansion joint…

Bracket BSP Type K2/A-B-FIX Bracket BSP Type K2/A-B-LOS

Bracket BSP Type K2/A-B-FIX Bracket BSP Type K2/A-B-LOS

Bracket BSP Type K2/A-B-FIX Bracket BSP Type K2/A-B-LOS

…. within places where standard bracket does not fit for (corners)

www.bspsystem.com

9

PRODUCTS Fixing systems for ventilated façades

A

luminum made substructure for fixing cladding panels consists of brackets and the profiles. It is used for precise fixing of external cladding panels, i.e.: fiber-cement, HPL, aluminum

composite, architectural concrete, aluminum louvers, and other cladding material. Brackets are used to transfer loads from the main grid. Depending on the distance between cladding panels and the main structure of the building, brackets of different outreach are used. In order to reduce assembly time and make the fixing work easier the shape of brackets has been designed for easy adjustment and proper lining of the grid observing required tolerances and variations in alignment. BSP brackets can correct variations from plan position of walls up to + / - 50 mm without the need to use leveling pads. Main grid consists generally of “T” profiles (KWR1, KWR3) used for connections of two cladding panels and “L” profiles (KWR2, KWR4, KWR5) appropriate to fix the panels in other areas. BSP profiles have specially shaped grooves on the outer surface what considerably increases the durability of both the grid and the outer coating in the junction area.



Increased capacity allowing for cost optimization when calculating mechanical parameters of the substructure.

Aluminum Bracket System

Advantages of extruded aluminum brackets applied for ventilated façades:



Patented foot leading to substantial improving durability of the bracket.



Extruded brackets compared to bent brackets have no initial stresses and cracks that weaken their mechanical

10

www.bspsystem.com

properties. •

Resistance to weather, especially when compared with steel brackets.



Light weight important for the cost of transportation.



Possibility of cuttings or drilling additional holes without the need for special anticorrosion treatment,



No galvanic corrosion at the interface with other aluminum elements.



High esthetics of fabrication: brackets can be optionally supplied as a powder coated or anodized.



Reduced delivery time and vast range of products available from stock.

PRODUCTS Fixing systems for ventilated façades Advantages of ventilated façades

Acoustic insulation

Bracket BSP for sliding points

Aluminum bracket BSP

Thermal insulation Bracket BSP for fixed points Ventilated cavity Vertical profile BSP Cladding panel Thermal insulation

Ventilated cavity Vertical profile BSP Cladding panel Thermal insulation

Ventilated cavity Aluminum bracket BSP

Thermal insulation

Cladding panel Vertical profile BSP Ventilated cavity Thermal insulation

Aluminum bracket BSP Thermal insulation

Cladding panel Vertical profile BSP Ventilated cavity Thermal insulation

Bracket BSP for sliding points

Bracket BSP for fixed points

Ventilated cavity Vertical profile BSP Cladding panel Thermal insulation

Fire resistance

www.bspsystem.com

Aluminum Bracket System

Bracket BSP for fixed points Thermal insulation Vertical profile BSP Cladding panel Thermal insulation

11

PRODUCTS Fixing systems for ventilated façades

Aluminum Bracket System

Bracket BSP Type KW1/A-B-Fix-Los

12

Description

A

B

Bracket BSP Type KW1/40-150 FIX 40-150

40

150

Bracket BSP Type KW1/40-120 FIX 40-120

40

120

Bracket BSP Type KW1/40-90 LOS 40-90

40

90

Bracket BSP Type KW1/40-60 LOS 40-60

40

60

Bracket BSP Type KW1/80-150 FIX 80-150

80

150

Bracket BSP Type KW1/80-120 FIX 80-120

80

120

Bracket BSP Type KW1/80-90 LOS 80-90

80

90

Bracket BSP Type KW1/80-60 LOS 80-60

80

60

Bracket BSP Type KW1/120-150-FIX

120

150

Bracket BSP Type KW1/120-120-FIX

120

120

Bracket BSP Type KW1/120-90-LOS

120

90

Bracket BSP Type KW1/120-60-LOS

120

60

Bracket BSP Type KW1/140-150-FIX

140

150

Bracket BSP Type KW1/140-120-FIX

140

120

Bracket BSP Type KW1/140-90-LOS

140

90

Bracket BSP Type KW1/140-60-LOS

140

60

Bracket BSP Type KW1/170-150-FIX

170

150

Bracket BSP Type KW1/170-120-FIX

170

120

Bracket BSP Type KW1/170-90-LOS

170

90

Bracket BSP Type KW1/170-60-LOS

170

60

Bracket BSP Type KW1/210-150-FIX

210

150

Bracket BSP Type KW1/210-120-FIX

210

120

Bracket BSP Type KW1/210-90-LOS

210

90

Bracket BSP Type KW1/210-60-LOS

210

60

www.bspsystem.com

PRODUCTS Fixing systems for ventilated façades

Description

A

Bracket BSP Type KW3/70-60/Fix/Los

60

Bracket BSP Type KW3/70-90/Fix/Los

90

Bracket BSP Type KW3/70-120/Fix/Los

120

Bracket BSP Type KW3/70-650/Fix/Los*

650

Aluminum Bracket System

Bracket BSP Type KW3/A-B-Fix/Los

* This kind of bracket is recommended for renovation works without removing the existing thermal insulation.

www.bspsystem.com

13

PRODUCTS Fixing systems for ventilated façades Adjustment range of BSP aluminum substructure

KWW1/65-A

Use of BSP extension piece KWP1/A-B

-A 93 /1 P2 KW Profile BSP Type KWR1

Extension piece BSP Type KWP1/A-B

Aluminum Bracket System

Bracket BSP Type KW1/210

Profile BSP Type KWR1

Bracket BSP Type KW1/210

Profile BSP Type KWR1

Bracket BSP Type KW1/A-B-Fix

Bracket BSP Type KW1/A-B-Fix

Bracket BSP Type KW1/A-B-Fix

Adjustment from 42 mm to 370 mm

14

www.bspsystem.com

PRODUCTS Fixing systems for ventilated façades

135

Extension piece BSP Type KWP1/A-B

3,0

Description

Aluminum Bracket System

A

A

Extension piece BSP Type KWP1/135-150

150

Extension piece BSP Type KWP1/135-120

120

Extension piece BSP Type KWP1/135-90

90

Extension piece BSP Type KWP1/135-60

60

www.bspsystem.com

15

PRODUCTS Fixing systems for ventilated façades Foot BSP Type KWW1/A-B

Description

A

Foot BSP Type KWW1/65-150

150

Foot BSP Type KWW1/65-120

120

Foot BSP Type KWW1/65-90

100

Foot BSP Type KWW1/65-60

60

Aluminum Bracket System

Support BSP Type KWP2/A-B

Description

A

Support BSP Type KWP2/193-150

150

Support BSP Type KWP2/193-120

120

Support BSP Type KWP2/193-90

100

Support BSP Type KWP2/193-60

60

Bracket with the additional support Used for bigger loads and outreaches and also as horizontal brackets Support BSP Type KWP2/193-A

KW1/210-A

Foot BSP Type KWW1/ 1// 65-A

16

www.bspsystem.com

PRODUCTS Fixing systems for ventilated façades Profile BSP Type KWR1

15,467 cm4

ly

26,316 cm4

Wx

2,776 cm3

Wy

4,386 cm3

Surface

3,582 cm2

Mass

Description

lx

Profile BSP Type KWR1 lengths 3100 mm Profile BSP Type KWR1 lengths 2700 mm

0,971 kg/m

Aluminum Bracket System

Profile BSP Type KWR2

Description Profile BSP Type KWR2 lengths 3100 mm Profile BSP Type KWR2 lengths 2700 mm

11,877 cm4

ly

5,038 cm4

Wx

2,467 cm3

Wy

1,279 cm3

Surface

2,278 cm2

Mass

lx

0,617 kg/m

www.bspsystem.com

17

PRODUCTS Fixing systems for ventilated façades Profile BSP Type KWR3

Description

Aluminum Bracket System

Profile BSP Type KWR3 lengths 3000 mm

18

lx

5,864 cm4

ly

16,546 cm4

Wx

1,432 cm3

Wy

3,309 cm3

Surface

2’963 cm2

Mass

0,803 kg/m

Profile BSP Type KWR4 Profile 50 x 50 x 2 mm lx

4,908 cm4 3

Wx

1,335 cm

Surface

1,960 cm2

ly

4,908 cm4

Wy

1,335 cm3

Mass

0,531 kg/m

Profile 40 x 40 x 2 mm lx

Description

A

B

Profile BSP Type KWR4 - 50 x 50 mm, lengths 3000 mm

50

50

Profile BSP Type KWR4 - 40 x 40 mm, lengths 3000 mm

40

40

www.bspsystem.com

2,453 cm4 3

Wx

0,835 cm

Surface

1,566 cm2

ly

2,453 cm4

Wy

0,835 cm3

Mass

0,425 kg/m

PRODUCTS Hanging brackets system (horizontal rail)

B

SP hanging bracket system allows for precise fixing of HPL cladding, fiber cement and other types of cladding panels used both indoors and on the external ventilated façades. The hanging

system enables the distance adjustment in the vertical plane up to 10 mm. To secure precise vertical adjustment, a screw and a nut set in a particularly designed guide channel are used. To facilitate the operation of hole drilling there are markers on the surface of the profile. As additional advantage BSP hanging system enables easy removing and re-attachment, without damaging the panels and profiles. The system is used in the following configurations: •

When there is no need for leveling uneven walls and the use of thermal insulation, supporting profile KWRW is mounted directly to the wall. The hanging element is attached directly to the back of the cladding panel (fixing with glue or undercut anchors). - Fig. 1



When thermal insulation is required, then we apply additional vertical supporting profiles attached to the wall with KW1 brackets. These profiles are used to fix the horizontal KWRW supporting profiles, on which cladding panels are mounted. - Fig. 2

Aluminum Bracket System

Profile BSP Type KWR1/ KWR2

Fixing with glue

Fixing with glue

Profile BSP Type KWRW

Fig. 1

Fixing with undercut anchor

Fixing with undercut anchor

Bracket BSP Type KW1/A-B

Fig. 2

www.bspsystem.com

19

PRODUCTS Bracket systems for interior cladding Bracket BSP Type KW1/40-A-Fix/Los

A

A

Bracket BSP type KW1/40 and profile type KWR5 are used for mounting the internal panels in areas where no additional thermal insulation is needed. The adjustment of distance between the wall surface and cladding panels is from 45 mm to 90 mm. This solution is particularly recommended for fixing by glue or rivets.

Aluminum Bracket System

Description

A

Bracket BSP Type KW1/40-120/Fix/Los

120

Bracket BSP Type KW1/40-90/Fix/Los

90

Bracket BSP Type KW1/40-60/Fix/Los

60

Profile BSP Type KWR5

lx

2,305 cm4

ly

6,454 cm4

Wx

0,785 cm3

Wy

1,607 cm3

Surface

20

www.bspsystem.com

1,794 cm

2

Mass

0,486 kg/m

PRODUCTS Floor to Floor BSP System

T

he BSP Floor to Floor has been designed to minimize the amount of substructure between the façade panels and the wall of the building. The principle of the Floor to Floor system is to

increase the distance between the neighboring brackets, mostly from floor to floor of a building. Brackets are fixed to the structural elements of the building, most often to the face of the floor slab. Brackets K1 and K2 meet elevated requirements for mechanical capacity and rigidity of the supporting elements in order to transfer considerable stresses resulting from rare distribution of brackets fixed only in the floor slabs at floor height. On the other hand, vertical profiles KWR6 have reinforced the structure, so that it can safely carry the increased wind load and the deflection forces do not exceed the critical value. An undoubted advantage of load-bearing profiles KWR6 is specially shaped grooved outer surface, significantly increasing the stability of the connection between profile and panel.



Reduced number of brackets allowing for significant reduction of thermal bridges.



Reduced number of brackets allowing for reduced installation time.



Mounting brackets to the bearing structure of the building, usually reinforced concrete simplifies installation and allows for using standard expansion anchors instead of expensive chemical anchors.

Profile BSP Type KWR6

lx Wx Surface

81,280 cm4 15,157 cm

3

6,960 cm2

ly

47,822 cm4

Wy

7,970 cm3

Mass

Aluminum Bracket System

Advantages of BSP Floor to Floor system:

1,886 kg/m

www.bspsystem.com

21

PRODUCTS Floor to Floor BSP System

Span between slabs

Aluminum Bracket System

Span between slabs

Sections and models

Fig. 3 - 3D Model

Fig. 4 - The floor section

Fig. 5 - Cross section of internal and external corners

22

www.bspsystem.com

PRODUCTS Additional substructure elements Bracket BSP Type KWD/A-B

Description

A

B

Bracket BSP Type KWD/85-60

85

60

Bracket BSP Type KWD/85-80

85

80

Bracket BSP Type KWD/85-100

85

100

Bracket BSP Type KWD/85-120

85

120

Bracket BSP Type KWD/85-140

85

140

Bracket BSP Type KWD/85-160

85

160

Bracket BSP Type KWD/160-60

160

60

Bracket BSP Type KWD/160-80

160

80

Bracket BSP Type KWD/160-100

160

100

Bracket BSP Type KWD/160-120

160

120

Bracket BSP Type KWD/160-140

160

140

Bracket BSP Type KWD/160-160

160

160

Profile BSP Type KWRY “Y” type profile for aluminum composite panels ON ST REQUE

lx

8,605 cm4

ly

13,566 cm4

Wx

1,890 cm3

Wy

3,015 cm3

Surface

3,120 cm2

Mass

Aluminum Bracket System

B

Bracket for timber framework

0,846 kg/m

www.bspsystem.com

23

PRODUCTS Additional substructure elements Profile BSP Type RW2 Omega profile Profile RW2 is designed for mounting panels on walls without vertical deviation 40

30

50

Aluminum Bracket System

60

24

Description

A

B

Profile BSP Type RW2

30

25

Profile BSP Type RW2

40

15

Profile BSP Type RW2

50

50

Profile BSP Type RW2

60

15

Profile BSP Type KWRK The special profile for mounting heavy cladding panels The system consists of the support profile KWRK and accessories for fixing the panels made of stone or other different cladding materials of unusual thickness. Details on optional accessories, used for fixing (hangers, hooks etc.) are available on: www.bspsystem.com

ON ST REQUE

www.bspsystem.com

PRODUCTS System “BSP Solar” for solar panels fixing on façades

B

SP Solar System is dedicated to mounting of solar panels or collectors on the building walls, such as ventilated façade. The system allows for independent installation of solar panels, as

well as their harmonious incorporation into a ventilated façade among standard cladding panels. The system can be applied to fix all types of solar panels and collectors designed to operate in the vertical position. Advantages of horizontal installation of solar panels as a façade in comparison to traditional roofing installation: •

Increased solar coverage, which is the percentage of energy supplied by the solar panels in relation to the demand for energy, depending on the insolation quantities of the collectors and the size of the storage tank.



Continuous cooling by the air flow circulation (chimney effect) in the ventilation gap between the solar panel and the wall of building.



Easy access to the panels to remove impurities that cause efficiency loss.



No risk of snow cover and full efficiency in the winter.



A smaller distance between the collector and the storage tank, usually placed in the boiler room on the ground floor.

For the details please refer to www.bspsystem.com

Aluminum Bracket System

W3 - fix point

W3 - fix point

W2 - sliding point

www.bspsystem.com

25

PRODUCTS Decorative profiles Profile BSP Type KWN1 Outward angle profile If corners at the junction of cladding panels require high aesthetics, decorative profiles are used to hid the joints.

74

2

12

14

2

Profile BSP Type KWN2 Inlet angle profile

94

62 20

12

12

Aluminum Bracket System

2

Profile BSP Type KWF1 Joint profile Joint profiles are used to cover the gaps between panels in public spaces, as a solution against acts of vandalism. .

3

6

o

45

30

26

www.bspsystem.com

12

EXAMPLES AND CALCULATION Fixing systems for ventilated façades Aluminum substructure BSP- examples of applications

A wide range of regulation helps to avoid problems with the tolerance of wall construction +/-20 mm.

Aluminum Bracket System

Horizontal brackets BSP - examples of applications

The use of substructure in horizontal position, allows for the cost optimization of the façade when narrow horizontal panels are to be fixed. www.bspsystem.com

27

EXAMPLES AND CALCULATION Fixing systems for ventilated façades Exemplary assembly scheme

Cladding panel BSP Aluminum profile Thermal insulation Fixing screw BSP bracket KW1 Fixing anchor EPDM thermal insulation pad Façade profile EPDM thermal insulation pad Fixing anchor

Cladding panel

BSP bracket KW1

Thermal insulation

Waterproofing

Fixing screw BSP Aluminum profile Painted rivet Al/A2

Fixing anchor EPDM thermal insulation pad

BSP Aluminum profile KWR2 Painted rivet Al/A2 Fixing screw

Aluminum Bracket System

BSP bracket KW1 Cladding panel

EPDM thermal insulation pad Fixing anchor BSP bracket KW1 Fixing screw Painted rivet Al/A2 BSP Aluminum profile Cladding panel

Thermal insulation

Thermal insulation

BSP Aluminum profile Painted rivet Al/A2 Fixing screw BSP bracket KW1 Fixing anchor EPDM thermal insulation pad

BSP Aluminum profile Painted rivet Al/A2 Fixing screw Painted rivet Al/A2 BSP Aluminum profile Cladding panel Thermal insulation

BSP bracket KW1 Fixing anchor EPDM thermal insulation pad Cladding panel Thermal insulation

BSP Aluminum profile Painted rivet Al/A2 Fixing screw BSP bracket KW1 Fixing anchor EPDM thermal insulation pad

Profile BSP Type KWN2 EPDM thermal insulation pad Fixing anchor BSP bracket KW1

28

Painted rivet Al/A2

BSP Aluminum profile

Profile BSP Type KWN1

Painted rivet Al/A2 Fixing screw

Cladding panel Thermal insulation

Cladding panel Thermal insulation

www.bspsystem.com

Roughcast

EXAMPLES AND CALCULATION Fixing systems for ventilated façades Exemplary substructure layout

BSP aluminum bracket (fixed point) BSP aluminum bracket (sliding point) BSP aluminum L profile BSP aluminum T profile

Aluminum Bracket System

Example of calculation

www.bspsystem.com

29

EXAMPLES AND CALCULATION Fixing systems for ventilated façades Heat transfer reduction Ventilated façades is a solution characterized by high thermal bridge.

Aluminum Bracket System

Example of thermal calculation

2 ΔUt = α . λtAtnt .( Rt ) do Rth

α = 0,8 - Bracket entirely passes through thermal insulation λt = 200 W/mK - Thermal conductivity of aluminum At = 0,0002 m2 - Cross section area nt = 1- Number of brackets in 1 m2 do = 0,18 m - Thickness of insulation layer Rt = 5,81 m2K/W - Thermal resistance of insulation layer Rth = 6,1 m2K/W - Thermal resistance of façade without thermal bridges Δ U (t) = 0,162 Thermal conductance Attention! Despite 5 mm pads the thermal bridge is significant.

To reduce thermal bridge problem BSP Bracket System Polska BSP proposes:

30



Use of foamed PVC pads.



Use of BSP substructure which allows for using less brackets what in turn leads to reduction of thermal bridges.



Use of brackets with non-metallic element (under development by BSP).

www.bspsystem.com

ADDITIONAL SERVICES: BSP Bracket System Polska provides the following additional services: Powder coating from RAL color card Anodizing Custom tooling Individual technical design Static calculations Support for installers Cost optimization of substructure Optimization of panels cutting Technical advice Coordination of projects Metal case with exemplary BSP system products

Suitcases products

Aluminum Bracket System

• • • • • • • • • • •

Projects Individual

Painting RAL colors

www.bspsystem.com

31

Aluminum Bracket System

REFERENCES Excerpt from reference list

32



IKEA Retail Park Targowek - Warsaw - façade surface: more than 1000 m2, General contractor „KARMAR S. A.”



RTV Euro AGD - Warszawa, General contractor „KARMAR S. A.”



Apartment and services complex Zabłocińska str. Warsaw, General contractor „TYNKBUD-1 Sp. z o. o.”



Apartment and services complex Wańkowicza str. Warsaw, General contractor „TYNKBUD-1 Sp. z o. o.”



Construction of the Louis Armstrong Municipal Amphitheatre in Iława, General contractor Iławskie Przedsiębiorstwo Budowlane „IPB” Sp. z o. o.



„Zink Power Wielkopolska” in Krągola near Konin - façade surface: more than 1000 m2, General contractor „TULCON S. A.”



Modular kindergarden building Św. Hieronima str. in Warsaw, General contractor „PREFABRYKA Sp. z o. o.”



Modular kindergarden building Turmoncka str. Warsaw, General contractor „PREFABRYKA Sp. z o. o.”



Apartment complex Jesiennych Liści str. Warsaw, General contractor Generalny Wykonawca firma „ALISMA CONSTRUCTION S. A.”



Sports hall Legionowo, General contractor „MOSTOSTAL WARSZAWA S. A.”



Office building „Oxygen”Malczewskiego str. Szczecin, General contractor „EIFFAGE BUDOWNICTWO MITEX S. A.”



Apartment complex Międzyborska str. Warsaw, General contractor „TYNKBUD-1 Sp. z o. o.”



Apartment complex Wyścigowa str. Warsaw, General contractor „UNIBEP S. A.”



Museum of Contemporary Art in Krakow - façade surface: more than 1500 m2, General contractor „Warbud S. A.”



Apartment building Malcanowo, Private investor



Stadium Arka in Gdynia, General contractor „Budimex-Dromex S. A.”



Sports center Wielka Krokiew Zakopane, General contractor „Budimex-Dromex S. A.”



Philharmonic Hall Kielce, General contractor „Unibep S. A. i Unimax S. A.”



Service building for subway station Kabaty, General contractor „Budimax-Dromex S. A.”



Building of Institute of Aviation Warsaw - façade surface: more than 1000 m2, General contractor „Dorbud S. A.”



Storage-office building - Sobiekursk near Karczewo, General contractor „Pro-Bud S. A.”



Apartment-commercial building Warszawska str. Kielce, General contractor „Nowbud”

www.bspsystem.com



Apartment complex Argentyńska str. Warsaw - façade surface: more than 1000 m2, General contractor „ALISMA CONSTRUCTION S. A.”



Storage-office building Annopol str. Warsaw, General contractor „Hochtief Polska S. A.”



Apartment complex „Saska” Warsaw, General contractor „UNIBEP S. A.”



Apartment complex Parkowa str. Krakow, General contractor „PRZ w Krakowie S. A.”



Apartment building Puławski astr. Piaseczno, General contractor „ALISMA CONSTRUCTION S. A.”



Office building Bysławska Warsaw - façade surface: more than 2500 m2, Investor: Mera Pnefal S. A.



Individual house Spartańska str. Warsaw, Private investor



Individual house Komorów, Private investor



Interior cladding of tunnels at Chopin Airport Warsaw, General contractor „PeKaBud”



ASP Academy of Fine Arts Łódź - façade surface: more than 3000 m2, General contractor „Budimex”



Apartment building Serocka str. Warsaw, General contractor „Tryboń”



Theater Suwałki - façade surface: more than 1000 m2, Contractor „A&D Suwałki”



Apartment complex Mozaika Mokotow Warsaw - façade surface: more than 1000 m2, General contractor „UNIBEP S. A.”



Shopping Center Jantar in Słupsku - façade surface: more than 5000 m2, Contractor „Termatex”



Faculty of Phisics (CENT II) UW in Warszawa - façade surface: more than 2000 m2, General contractor „Karmar S. A.”



Cotex Office Center in Płock - façade surface: more than 4000 m2, Investor „Budoplan”



Construction of production plant Weyerhaeuser in Gdańsk, General contractor „Budimex”



Olecko District Court building, General contractor „Skanska”



University Hospital in Białymstok - façade surface: more than 6000 m2, General contractor „Budimex”



„Konstruktorska Business Center” Warszawa - façade surface: more than 4000 m2, General contractor „HB Reavis Construction PL Sp. z o. o.”



Apartment complex IN CITY Siedmiogrodzka/Karolkowa str. Warsaw - more than 1500 m2, General contractor „Unibep S. A.”

www.bspsystem.com

Aluminum Bracket System

REFERENCES Excerpt from reference list

33

Aluminum Bracket System

REFERENCES Photographs of selected objects

34

Sports hall in Legionowo

IKEA Retail Park Targowek - Warsaw

Museum of Contemporary Art in Krakow

RTV Euro AGD - Warsaw

Construction of the Louis Armstrong Municipal Amphitheatre in Iława

Office building of the Institute of Aviation in Warsaw

Office Building Mera Pnefal S.A. Warsaw

Apartment complex - Zabłocińska str. in Warsaw

www.bspsystem.com

Interior cladding of tunels at Chopin Airport Warsaw

Apartment complex Mozaika Mokotow Warsaw

Apartment complex Wyścigowa str. Warsaw

Apartment building Serocka str. in Warsaw

Apartment-commercial complex Wańkowicza str. Warsaw

Apartment complex „Saxon” in Warsaw

Residential building Argentynska str. Warsaw

Apartment buildings Wilanow str. in Warsaw

Aluminum Bracket System

REFERENCES Photographs of selected objects

www.bspsystem.com

35

BSP Bracket System Polska Sp. z o.o. ul. Stanisława Augusta 73 lok. 17 03-846 Warszawa, Polska +48 22 243 09 70 e-mail: [email protected] www.bspsystem.com

EUROPEAN UNION EUROPEAN REGIONAL DVELOPMENT FUND

Suggest Documents