D6600
Computer Interface Manual
EN
Receiver/Gateway
D6600 | Computer Interface Manual | Trademarks
Trademarks Microsoft®, Windows®, Windows NT® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Modem IIIa2 is a trademark of Bosch Security Systems, Inc.
2
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Contents .
Contents 1.0 2.0 2.1 2.2 3.0 3.1 3.2 4.0 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.1.8 4.1.9 4.1.10 4.1.11 4.1.12 4.1.13 4.1.14 4.1.15 4.1.16 4.1.17 4.1.18 4.1.19 4.1.20 4.1.21 4.1.22 4.1.23 4.1.24 4.1.25 4.1.26 4.1.27 4.1.28 4.1.29 4.1.30 4.2 4.2.1
Documentation Conventions.........................7 System Connection ..........................................7 D6680 Network Adapter Connection ..............7 Direct Connection – RS-232 .............................8 Making the Right Connection.......................8 COM3 DB9 Connector .....................................8 Selecting Program Options in the D6600 ........9 Computer Communication Protocols........10 D6500 Mode Messages ....................................10 Acron Super Fast (Message Type 9)...............10 Ademco 4-1 Express (Message Type b).........11 Ademco 4-2 Express (Message Type c) .........11 Ademco Contact-ID (Message ♦Type a) .......12 Ademco High Speed, 4-8-1 (Message Type f)...............................................12 ADT SIA (Message Type S) ............................13 Caller ID (Message Type e).............................13 CFSK (Message Type i) ...................................14 Common Formats (Message Type 1) .............14 DNIS/ANI (Message Type N) ........................15 DSC 4-3 (Message Type d)..............................15 FBI Super Fast (Message Type F) ...................16 ITI (Message Type I)........................................16 Link Test (Message Type 1) ............................16 Robofon (Message Type j)...............................17 Sescoa Super Speed (Message Type 7) ..........18 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ....................19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)....................20 Seriee FSK (Message Type k)..........................21 Seriee DTMF (Message Type l) ......................21 SIA (Message Type S) ......................................22 Silent Knight FSK0 (Message Type 1) ...........22 Silent Knight FSK2 (Message Type m) ..........25 Silent Knight FSK80 D6500 mode (Message Type E) .............................................25 Telim (Message Type n) ..................................26 Text Message (Message Type 3) .....................26 Varitech FSK 4-1 (Message Type 1)...............27 Varitech FSK 4-2 (Message Type 1)...............27 VONK (Message Type V)...............................28 X-SIA Text (Message Type S).........................28 SIA Mode Messages.........................................29 Acron Super Fast (Message Type 9)...............29
Bosch Security Systems | 1/05 | 4998122703D
4.2.2 4.2.3 4.2.4 4.2.5
Ademco Contact-ID (Message Type a) ......... 30 Ademco 4-1 Express (Message Type b) ........ 31 Ademco 4-2 Express (Message Type c)......... 32 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) .............................................. 33 4.2.6 ADT SIA (Message Type ) ................ 34 4.2.7 Caller ID (Message Type ) ................ 34 4.2.8 CFSK (Message Type I) .................................. 35 4.2.9 Common Formats (Message Type )................................................... 35 4.2.10 DNIS/ANI (Message Type N)........................ 36 4.2.11 DSC 4-3 (Message Type d) ............................. 37 4.2.12 FBI Super Fast (Message Type F) .................. 38 4.2.13 ITI (Message Type I) ....................................... 39 4.2.14 Link Test (Message Type ) ................ 39 4.2.15 RB2000 (Message Type R) Description ........ 40 4.2.16 Robofon (Message Type j) .............................. 41 4.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ................... 41 4.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) ................... 42 4.2.19 Seriee DTMF (Message Type l)...................... 43 4.2.20 Seriee FSK (Message Type k) ......................... 43 4.2.21 Sescoa Super Speed (Message Type 7).......... 44 4.2.22 Silent Knight FSK() (Message Type )................................................... 45 4.2.23 Silent Knight FSK1 (Message Type m).......... 45 4.2.24 Silent Knight FSK2 (Message Type m).......... 47 4.2.25 Silent Knight FSK80 (Message Type E) ........ 48 4.2.26 Telim (Message Type n).................................. 49 4.2.27 Varitech FSK 4-1 (Message Type )................................................... 49 4.2.28 Varitech FSK 4-2 (Message Type )... 50 4.2.29 VONK (Message Type V) .............................. 50 4.2.30 X-SIA text (Message Type ) .............. 51 4.3 Input Command Processing ........................... 52 4.3 Input Command Processing ........................... 52 Appendix A: Contact ID Event Code Classifications ................................................. 53 Appendix B: Internal Messages................................ 58 Appendix C: Radionics Modem IIIa2 Messages.... 61 C.1 Bosch Security Systems Zonex and COMEX Translation ..................................... 140 Appendix D: NetCom Messages............................. 141 Appendix E: Pulse Output ....................................... 144 Appendix F: Format ID (Identified by Message Type)............................................................... 149 Appendix G: ADT SIA Report Codes................... 152
3
D6600 | Computer Interface Manual | Contents Appendix H: D6600 RB2000 Messages ..................154 Appendix I: D6600 SafeCom Messages.................161
Table 9: Table 10:
Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: Figure 17: Figure 18: Figure 19: Figure 20: Figure 21: Figure 22: Figure 23:
Table 11: D6600 System – Standard/Network Automation ..................................................7 D6600 System – Direct Connect ...............8 Null Modem Cable Configuration ............8 Straight-through Modem Cable Configuration ...............................................8 Modem Cable Pin Definitions ...................9 Message sent to printer .............................29 Message sent to printer .............................30 Message sent to printer .............................31 Message sent to printer .............................32 Message sent to printer .............................33 Message sent to printer .............................36 Message sent to printer .............................37 Message sent to printer .............................38 Single message sent to Printer..................40 Multiple messages sent to printer ............40 Message sent to printer .............................42 Message sent to printer .............................42 Message sent to printer .............................44 Message sent to printer .............................48 Message sent to printer .............................51 Contact ID format .....................................53 D6200 Receiver Software Line Card Configuration ...........................................144 SafeCom message characters .................161
Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8:
4
Recommended Programming Selections..9 D6600 Line Number/Group Number Conversion Table ......................................10 Message Type 9 (Acron Super Fast) Byte Description .................................................10 Message Type b (Ademco 4-1 Express) Byte Description ........................................11 Message Type c (Ademco 4-2 Express) Byte Description ........................................11 Message Type a (Ademco Contact ID) Byte Description ........................................12 Message Type f (Ademco High Speed, 4-81) Byte Description....................................12 ADT SIA (Message Type S) Byte Description .................................................13
Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Table 18: Table 19:
Table 20:
Table 21: Table 22: Table 23: Table 24: Table 25: Table 26: Table 27: Table 28: Table 29: Table 30: Table 31: Table 32: Table 33: Table 34:
Caller ID (Message Type e) Byte Description ................................................ 13 CFSK (Message Type i) Byte Description ................................................ 14 Common Formats (Message Type 1) Byte Description ................................................ 14 DNIS/ANI (Message Type N) Byte Description ................................................ 15 DSC-4-3 (Message Type d) Byte Description ................................................ 15 FBI Super Fast (Message Type F) Byte Description ................................................ 16 ITI (Message Type I) Byte Description.. 16 Link Test (Message Type 1) Byte Description ................................................ 17 Robofon (Message Type j) Byte Description ................................................ 17 Sescoa Super Speed (Message Type 7) Byte Description........................................ 18 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description ................................................ 19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description ................................................ 20 Seriee FSK (Message Type k) Byte Description ................................................ 21 Seriee DTMF (Message Type l) Byte Description ................................................ 21 SIA (Message Type S) Byte Description 22 Silent Knight FSK1 (Message Type m) Byte Description........................................ 22 Optional Silent Knight SK1 (Message Type m) Byte Description........................ 23 Silent Knight Automation Format .......... 24 Silent Knight FSK2 (Message Type m) Byte Description........................................ 25 Silent Knight FSK80 (Message Type E) Byte Description........................................ 25 Telim (Message Type n) Byte Description .................................................................... 26 Text Message (Message Type 3) Byte Description ................................................ 26 Varitech FSK 4-1 (Message Type 1) Byte Description ................................................ 27 Varitech FSK 4-2 (Message Type 1) Byte Description ................................................ 27 VONK (Message Type V) Byte Description ................................................ 28 X-SIA Text (Message Type S) Byte Description ................................................ 28 Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Contents . Table 35: Table 36: Table 37: Table 38: Table 39: Table 40: Table 41: Table 42: Table 43: Table 44: Table 45: Table 46: Table 47: Table 48: Table 49: Table 50: Table 51: Table 52: Table 53: Table 54: Table 55: Table 56: Table 57: Table 58: Table 59: Table 60: Table 61:
Acron Super Fast (Message Type 9) Byte Description .................................................29 Acron Super Fast (Message Type 9) Printer Output............................................29 Ademco Contact-ID (Message Type a) Byte Description ........................................30 Ademco Contact-ID (Message Type a) Printer Output............................................30 Ademco 4-1 Express (Message Type b) Byte Description ........................................31 Ademco 4-1 Express (Message Type b) Printer Output............................................31 Ademco 4-2 Express (Message Type c) Byte Description ........................................32 Ademco 4-2 Express (Message Type c) Printer Output............................................32 Ademco High Speed 4-8-1, SCANCOM 48-1 (Message Type F) Byte Description ..33 Ademco High Speed, 4-8-1 (Message Type f) Printer Output ........................................33 ADT SIA (Message Type ) Byte Description .................................................34 Caller ID (Message Type ) Byte Description .................................................34 CFSK (Message Type I) Byte Description .................................................35 Common Formats (Message Type ) Byte Description ........................35 DNIS/ANI (Message Type N) Byte Description .................................................36 DSC 4-3 (Message Type d) Byte Description .................................................37 DSC 4-3 (Message Type d) Printer Output.........................................................37 Event Code Table .....................................37 Printer Output Codes................................37 FBI Super Fast (Message Type F) Byte Description .................................................38 FBI Super Fast (Message Type F) Printer Output.........................................................38 Event Code Table .....................................38 Printer Output Codes................................38 ITI (Message Type I) Byte Description ..39 Link Test (Message Type ) Description .................................................39 RB2000 (Message Type R) Byte Description .................................................40 RB2000 (Message Type R) Printer Output .....................................................................40
Bosch Security Systems | 1/05 | 4998122703D
Table 62: Table 63:
Table 64:
Table 65:
Table 66:
Table 67: Table 68: Table 69: Table 70: Table 71: Table 72: Table 73: Table 74: Table 75: Table 76: Table 77: Table 78: Table 79: Table 80: Table 81: Table 82: Table 83: Table 84: Table 85: Table 86:
Robofon (Message Type j) Byte Description ................................................ 41 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description ................................................ 41 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Printer Output ........................................................ 42 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description ................................................ 42 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Printer Output ........................................................ 42 Seriee DTMF (Message Type l) Byte Description ................................................ 43 Seriee FSK (Message Type k) Byte Description ................................................ 43 Sescoa Super Speed (Message Type 7) Byte Description........................................ 44 Sescoa Super Speed (Message Type 7) Printer Output ........................................... 44 Silent Knight FSK0 (Message Type ) Byte Description........................ 45 Silent Knight FSK1 (Message Type m) Byte Description........................................ 45 Optional Silent Knight FSK1 (Message Type m) Byte Description........................ 46 Silent Knight FSK1 Optional Outputs.... 46 Silent Knight FSK2 (Message Type m) Byte Description........................................ 47 Silent Knight FSK80 (Message Type E) Byte Description........................................ 48 Silent Knight FSK80 Printer/LCD output ......................................................... 48 Telim (Message Type n) Byte Description ................................................ 49 Varitech FSK 4-1 (Message Type ) Byte Description........................................ 49 Varitech FSK 4-2 (Message Type ) Byte Description........................................ 50 VONK (Message Type V) Byte Description ................................................ 50 X-SIA text (Message Type ) Byte Description ................................................ 51 X-SIA Printer/LCD output ...................... 51 ASCII Text Message to Automation Port ............................................................. 52 Input Command Output Messages......... 52 Event Codes .............................................. 53
5
D6600 | Computer Interface Manual | Contents Table 87: Table 88: Table 89: Table 90: Table 91: Table 92: Table 93: Table 94: Table 95: Table 96: Table 97: Table 98: Table 99: Table 100: Table 101: Table 102: Table 103: Table 104: Table 105: Table 106: Table 107: Table 108: Table 109: Table 110: Table 111: Table 112:
6
Internal Messages ......................................58 Radionics Modem IIIa2 Messages ...........61 Point to ZONEX Translation.................140 User ID to COMEX Translation...........140 Reported Zone/ID to Actual Point/ID .140 NetCom Messages...................................141 Pulse 3/1 Format .....................................144 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1 ...............................................145 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2 ...............................................145 Pulse 3/2 ...................................................146 Pulse 4/1 ...................................................146 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 ...........................................147 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 ...........................................147 Pulse 4/2 ...................................................148 Pulse 4/3 ...................................................148 Generic Byte Description .......................149 Generic SIA Byte Description ...............149 Message Examples ..................................150 ADT SIA Report Codes .........................152 D6600 RB2000 Messages .......................154 D6600 Virtual Line Conversion Table .161 D6600 SafeCom Messages - Line Card or Account Signals .......................................162 D6600 SafeCom Messages - Intercepted Control Panel Signals..............................165 Explanation of Automation Output Items (within Message Body only) ...................167 Explanation of Printer Output Items ....168 Supported Event Codes..........................169
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Contents .
1.0 Documentation Conventions Important Notes - Information for successful operation and programming. Also tips and shortcuts can be included here. Caution - These caution the operator that physical damage to the program or equipment might occur.
2.0 System Connection 2.1
D6680 Network Adapter Connection
Use the D6680 Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot receive network data (Figure 1). Refer to Special Bosch Security Systems D6600 NetCom Applications in the D6600 NetCom System Guide (P/N: 4998122712). Figure 1:
D6600 System – Standard/Network Automation
Warning - These warn of the possibility of physical damage to the operator.
1 2
3 4
5 6 7 8 12345678*
Bosch Security Systems | 1/05 | 4998122703D
Automation PC Connection - PC COM1 to D6680 D6680 Connection - D6680 to hub Hub Second D6680 Connection - D6680 to D6600 COM4 D6600 Receiver For automation packages with network capabilities: The packet format received from the D6600 is the same as for RS-232 reporting, execpt an internet protocol (IP) and user datagram protocol (UDP) header is stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation software can support the network communication easily by calling Socket functions, both provided in Windows and Unix. by using the built-in IP connections (or sockets) available in Windows and Unix.
7
D6600 | Computer Interface Manual | 3.0
2.2
Making the Right Connection
Direct Connection – RS-232
Figure 2 show a D6600-System using any manufacturer’s automation software package directly connected to a D6600 Receiver.
3.0 Making the Right Connection 3.1
Figure 2:
D6600 System – Direct Connect
COM3 DB9 Connector
The COM3 Port uses a standard DB9 female connector. The suggested connection to the computer is shown in Figure 3 to Figure 5. When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a null-modem cable must be used. One possible configuration for a null modem cable is shown in Figure 3.
1
2
Figure 3:
3
1 - Automation PC 2 - Connection - Automation PC COM1 to D6600 Receiver COM3 3 - D6600 Receiver
Null Modem Cable Configuration DTE DB-9 Pin
DTE DB-9 Pin
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
When connecting data terminal equipment to data communication equipment (DCE) (such as the D6600 COM port to a modem), a modem cable should be used (such as a straight-through cable shown in Figure 4). Figure 4:
8
Straight-through Modem Cable Configuration DTE
DCE
1
8
2
3
3
2
4
20
5
7
6
6
7
4
8
5
9
22
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Contents . Each pin of the modem cable is defined in Figure 5. Figure 5:
Modem Cable Pin Definitions 1
2 6
1 - Data carrier detect (DCD) 2 - Receive (RX) 3 - Transmit (TX) 4 - Data terminal ready (DTR) 5 - Signal-ground (SIG-GND)
3.2
3 7
4 8
5 9
6 - Data set ready (DSR) 7 - Ready to send (RTS) 8 - Clear to send (CTS) 9 - Ring indicator (RI)
Selecting Program Options in the D6600
Use the D6600 Keypad or the D6200 Programming Software to program the receivers. Below are the recommended selections for programming when connecting the receivers to an automation system. Additional selections can be found in the D6600 Program Entry Guide (P/N: 4998122702). Table 1:
ReceiverGateway Number Output Format
Baud Rate Link Test
Recommended Programming Selections Selects a number (01 to 99) that is included in every message to the computer in both D6500 and SIA modes Enable computer output messages in the selected format: SIA computer interface standard format, recommended (expanded reporting capabilities) D6500 21-character format output Use maximum speed supported by PC Tests if a supervision signal can be sent and received from the central station by the receiver
Bosch Security Systems | 1/05 | 4998122703D
9
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.0 Computer Communication Protocols 4.1
D6500 Mode Messages
In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2. Table 2:
D6600 Line Number/Group Number Conversion Table
Line# /Group # L01/G01 L02/G02 L03/G03 L04/G04 L05/G05 L06/G06 L07/G07 L08/G08
Converted to 1 2 3 4 5 6 7 8
Line# /Group # L09/G09 L10/G10 L11/G11 L12/G12 L13/G13 L14/G14 L15/G15 L16/G16
Converted to 9 A B C D E F G
Line # /Group # L17/G17 L18/G18 L19/G19 L20/G20 L21/G21 L22/G22 L23/G23 L24/G24
Converted to H I J K L M N O
Line # /Group # L25/G25 L26/G26 L27/G27 L28/G28 L29/G29 L30/G30 L31/G31 L32/G32
Converted to P Q R S T U V W
In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified. 4.1.1
Acron Super Fast (Message Type 9)
Acron Super Fast Example
Table 3: # 1 2 3-4 5 6-9 10-13 14-21 22
10
D6500 Byte Description 1 h
2 9
3 r
4 r
5 l
6 s
7 s
8 s
9 s
10 a
11 a
12 a
13 a
14 C
15 C
16 C
17 C
18 C
19 C
20 C
21 C
22 t
Message Type 9 (Acron Super Fast) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Channels Trailer Character
Description Optional. Check with the computer automation software for compatibility. 9 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits Channels 1 to 8 Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0 . 4.1.2
Ademco 4-1 Express (Message Type b)
4-1 Express Example
Table 4: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22
4.1.3
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
b
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
s
X
t
Message Type b (Ademco 4-1 Express) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character
Description Optional. Check with the computer automation software for compatibility. b Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message. Six spaces Account number, four digits One space Event Code, “A” as the default. Three spaces Zone number Typically, this is HEX 14.
Ademco 4-2 Express (Message Type c)
4-2 Express Example
Table 5: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22
Computer Communication Protocols
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
c
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
X
Y
t
Message Type c (Ademco 4-2 Express) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character
Description Optional. Check with the computer automation software for compatibility. c Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits One space Event Code, “A” as the default. Two spaces Event code and zone number Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
11
D6600 | Computer Interface Manual | 4.0 4.1.4
Ademco Contact-ID (Message •Type a)
Contact ID Example
Table 6:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
a
r
r
l
s
a
a
a
a
1
8
Q
X
Y
Z
G
G
C
C
C
t
Message Type a (Ademco Contact ID) Byte Description
# 1 2 3-4 5 6 7-10 11-12 13 14-16 17-18 19-21 22
4.1.5
Computer Communication Protocols
Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number 18 Qualifier XYZ GG CCC Trailer Character
Description Optional. Check with the computer automation software for compatibility. a Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message One space Account number, four digits Ademco Contact-ID format number Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event Class code and event code (see Appendix A) Group number Zone codes or user ID Typically, this is HEX 14.
Ademco High Speed, 4-8-1 (Message Type f) SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request
High Speed Example
Table 7:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
h
f
r
r
l
a
a
a
a
a
s
C
C
C
C
s
C
C
C
C
s
C
t
Message Type f (Ademco High Speed, 4-8-1) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23 24
Space CCCC Space CCCC Space C Trailer Character
12
a
Description Optional. Check with the computer automation software for compatibility. f Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Account number, up to six digits Account number less than six characters is right aligned with leading ASCII spaces. One space Channels 1 to 4 One space Channels 5 to 8 One space Supervisory channel Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0 . 4.1.6
ADT SIA (Message Type S)
ADT SIA Example
Table 8: # 1 2 3-4 5 6 7 8-11 12 13-32 33 34-35 36-39 40 41 42
4.1.7
Computer Communication Protocols
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
h
S
r
r
l
[
#
a
a
a
a
|
d
a
m
m
-
d
d
-
y
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
y
t
I
h
h
:
m
m
:
s
s
E
M
M
Z
Z
Z
Z
/
** *
t
ADT SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number space # Account Number | Date and Time E Event Code Zone / *** Trailer Character
Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message. One space # Up to sixteen digits in the account number. Separator. Indicates more data positions after account number. Date and time SIA block code SIA event code (refer to Appendix G ADT SIA Report Codes on page 152) Zone number Separator Next block of data Typically, this is HEX 14.
Caller ID (Message Type e)
Caller ID Example
Table 9:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
e
r
r
1
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
t
Caller ID (Message Type e) Byte Description
# 1 2 3-4 5 6-21
Title Header Character (h) Message Type Receiver Number Line/Group Number Caller ID
22
Trailer Character
Description Optional. Check with the computer automation software for compatibility. e Receiver gateway Number from 01 to 99 Line number in the receiver gateway that sent the message Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with leading ASCII spaces. Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
13
D6600 | Computer Interface Manual | 4.0 4.1.8
CFSK (Message Type i)
CFSK Example
Table 10: # 1 2 3-4 5 6-9 10-15 16-17 18-19 20-21 22
4.1.9
Computer Communication Protocols
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
i
r
r
l
s
s
s
s
a
a
a
a
a
a
T
T
E
E
s
s
t
CFSK (Message Type i) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number TT EE Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. i Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message. Four spaces Six digit account number Event Code Zone/User ID Two spaces Typically, this is HEX 14.
Common Formats (Message Type 1)
Type 1 Example
Table 11:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
l
r
r
l
a
a
a
a
a
a
a
a
a
a
E
E
y
y
y
y
t
Common Formats (Message Type 1) Byte Description
# 1 2 3-4 5 6-15
Title Header Character (h) Message Type Receiver Number Line Number Account Number
16-17
Event Code
18-21
Zone Number
22
Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Account number, up to ten digits. Account numbers less than ten characters are right aligned with leading ASCII spaces. Event codes define the type of signal received and interpreted by the D6500 receiver gateway. Zone or ID number sent by the communicator. Zone numbers less than four digits are right aligned with leading ASCII spaces. Typically, this is HEX 14.
The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, Radionics BFSK, Radionics Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option selected. The receiver gateway also sends internal and Radionics Modem IIIa² messages in either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Radionics Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.
14
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.1.10 DNIS/ANI (Message Type N) DNIS/ANI Example
Table 12: # 1 2 3-4 5 6 7 8-18 19 20-30 31
D6500 Byte Description
1 H
2 N
3 r
4 r
5 l
6 s
7 D
8 d
9 d
10 d
11 d
12 d
13 d
14 d
15 d
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
d
d
&
a
a
a
a
a
a
a
a
a
16
DNIS/ANI (Message Type N) Byte Description Title Header Character (H) Message Type Receiver Number Line/Group Number Space DNIS Identifier DNIS Number ANI Identifier (&) ANI Number Trailer Character
Description Optional. Check with the computer automation software for compatibility. N (Capital n) Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message One space DNIS identifier DNIS number, up to 11 digits ANI identifier ANI number, up to 11 digits Typically, this is HEX 14.
4.1.11 DSC 4-3 (Message Type d) DSC 4-3 Example
Table 13: # 1 2 3-4 5 6-11 12-15 16 17 18 19 20-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
d
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
X
Y
Y
t
DSC-4-3 (Message Type d) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space X YY Trailer Character
Description Optional. Check with the computer automation software for compatibility. d Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits One space Event Code, “A” as the default One space Event code number Zone number Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
15
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.12 FBI Super Fast (Message Type F) FBI Super Fast Example
Table 14: # 1 2 3-4 5 6-11 12-15 16 17-18 19 20-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
F
r
r
l
s
s
s
s
s
s
a
a
a
a
T
Z
Z
E
s
s
t
FBI Super Fast (Message Type F) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number T ZZ E Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. F (Capital f) Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits Zone type Zone number Event type Two spaces Typically, this is HEX 14.
4.1.13 ITI (Message Type I) ITI Example
Table 15: # 1 2 3-4 5 6-8 9 10 11-14 15 16 17-18 19 20 21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
I
r
r
l
s
s
s
a
T
a
a
a
a
G
I
Z
Z
E
W
N
t
ITI (Message Type I) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Panel Type Account Number G I ZZ E W N Trailer Character
Description Optional. Check with the computer automation software for compatibility. I (Capital i) Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message. Three spaces First digit account number Control panel Type Next four digit account number Group number Open/close (O/C) User ID Zone number Condition code Protection level was Protection level is Typically, this is HEX 14.
4.1.14 Link Test (Message Type 1) Link Test Example
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
1
r
r
0
s
s
s
s
s
s
s
s
s
s
s
@
s
s
s
s
t
The D6600 can automatically generate this message at the programmed intervals.
16
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. Table 16: # 1 2 3-4 5 6-15 16-17 18-21 22
Link Test (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Spaces Event Code Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99 Line number as zero for link test Eleven spaces Event code is @ for link test Four spaces Typically, this is HEX 14.
4.1.15 Robofon (Message Type j) Robofon Example
Table 17: # 1 2 3-4 5 6-9 10-15 16-17 18-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
j
r
r
l
s
s
s
s
a
a
a
a
a
a
E
E
s
s
s
s
t
Robofon (Message Type j) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number EE Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. j Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Four spaces Six digit account number Event code Four spaces Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
17
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.16 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example
Table 18: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20 21 22
18
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
7
r
r
l
s
s
s
s
s
s
a
a
a
a
s
I
A
A
C
s
t
Sescoa Super Speed (Message Type 7) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space I AA C s Trailer Character
Description Optional. Check with the computer automation software for compatibility. 7 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits One space Event code Two digit zone code or the first two digits user code Space if zone report, or the last digit user code One space Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Scancom 4-16-1, 5-16-1, 6-16-1 Example
Table 19:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
h
g
r
r
l
a
a
a
a
a
a
s
C
C
C
C
s
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
t
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23-26 27 28-31 32 33 34
Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character
Description Optional. Check with the computer automation software for compatibility g Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Account number, up to six digits Account numbers less than six characters are right aligned with leading ASCII spaces One space Channels 1 to 4 One space Channels 5 to 8 One space Channels 9 to 12 One space Channels 13 to 16 One space Supervisory channel Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
19
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Scancom 4-24-1 Example
Table 20:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
h
r
r
l
a
a
a
a
a
a
s
C
C
C
C
s
C
C
C
C
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43 44
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
t
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23-26 27 28-31 32 33-36 37 38-41 42 43 44
Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character
20
s
Description Optional. Check with the computer automation software for compatibility. h Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Account number, up to six digits. Account numbers less than six characters are right aligned with leading ASCII spaces One space Channels 1 to 4 One space Channels 5 to 8 One space Channels 9 to 12 One space Channels 13 to 16 One space Channels 17 to 20 One space Channels 21 to 24 One space Supervisory channel Typically, this is HEX 14.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.1.19 Seriee FSK (Message Type k) Seriee FSK Example
D6500 Byte Description
Table 21: # 1 2 3-4 5 6-11 12-16 17 18 19 20 -21 22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
k
r
r
l
s
s
s
s
s
s
a
a
a
a
a
s
E
s
Z
Z
t
20
21 22
Seriee FSK (Message Type k) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space ZZ Trailer Character
Description Optional. Check with the computer automation software for compatibility. k Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message. Six spaces Five digit account number One space Event code One space Zone number Typically, HEX 14
4.1.20 Seriee DTMF (Message Type l) Seriee DTMF Example
Table 22: # 1 2 3-4 5 6-7 8 9-14 15 16-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
h
l
r
r
l
L
L
*
a
a
a
a
a
a
*
16
17
18
19
. . .
t
Seriee DTMF (Message Type l) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number LL * Account number * *** Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 (lowercase L) Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Data length Data separator Four, five or six account numbers Data separator DTMF Seriee Data Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
21
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.21 SIA (Message Type S) SIA Example
D6500 Byte Description 1
h Table 23: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22
2
S
3
r
4
r
5
l
6
[
7
#
8
a
9
a
10
a
11
a
12
|
13
E
14
M
15
16
M
Z
17
Z
18
Z
19
20
21
Z
/
** t *
22
SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E Event Code Zone / *** Trailer Character
Description Optional Check with the computer automation software for compatibility S Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Open bracket # Up to sixteen digits may be used in the account number Separator, indicates more data positions after account number. SIA block code SIA Event code Zone number Separator Next block of data Typically, HEX 14
4.1.22 Silent Knight FSK0 (Message Type 1) Silent Knight FSK0 Example
Table 24: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22
22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
1
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
s
Z
t
Silent Knight FSK1 (Message Type m) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Spaces E Space Zone number Trailer Character
Description Optional Check with the computer automation software for compatibility 1 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Four digit account number One space Event code Three spaces Zone number Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. Optional Silent Knight SK1 (Message Type m): If menu item 2.5.16 in the D6600 Receiver is equal to 1, the following output is used. Silent Knight FSK1 Example
D6500 Byte Description 1 h
Table 25: # 1
2 m
3 r
r
5 l
6 s
7 a
8 a
9 a
10
11
12
13
14
15
16
17
18
a
a
a
a
a
“
Z
Z
“
19
20
21 22
. . .
t
Optional Silent Knight SK1 (Message Type m) Byte Description
6 7-14
Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number
15 16-17 18 19 21
“ ZZ “ *** Trailer Character
2 3-4 5
4
Description Optional Check with the computer automation software for compatibility m Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message One space Maximum eight-digit account code. If the account code is less than eight digits, enter the actual number of digits without a leading space. Separator First zone number, up to eight reports, one report has two digits Separator More data Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
23
D6600 | Computer Interface Manual | 4.0
Table 26:
Silent Knight Automation Format
Report Code
Description
00: 01 to 08: 09: 10 to 19: 20 to 29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41 to 49: 50 to 59: 60: 61 to 68: 69: 70: 71 to 78: 79: 80: 81 to 89: 90: 91 to 99:
Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09 Opening Opening 01 to 09
24
Computer Communication Protocols
To Automation 2 5 16=0(EEZZ) PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x OP00 OP0x
2 5 16=1(ZZ) 00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89 90 91 to 99
Note
x=1 to 8 x=0 to 9 x=0 to 9
x=1 to 9 x=0 to 9 x=1 to 8
x=1 to 9
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.1.23 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example
Table 27: # 1
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
m
r
r
l
s
a
a
a
a
a
a
a
a
“
E
E
Z
Z
“
* * *
Silent Knight FSK2 (Message Type m) Byte Description
6 7-14
Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number
15 16-19
“ EEZZ
20 21 22
“ *** Trailer Character
2 3-4 5
t
Description Optional Check with the computer automation software for compatibility m Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message One space Maximum eight-digit account code If the account code is less than eight digits, enter the actual number of digits without a leading space Separator First event and zone number If this is the only event, it will be ended with the terminator Up to eight reports One report has four digits: one-digit event code, one-digit condition code, two-digit zone code Separator Next data Typically, HEX 14
4.1.24 Silent Knight FSK80 D6500 mode (Message Type E) Silent Knight FSK80 Example
Table 28: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 24
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
E
r
r
l
s
s
s
s
s
s
A
A
A
A
s
A
s
s
X
Y
t
Silent Knight FSK80 (Message Type E) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space Filler character A Spaces XY Trailer Character
Description Optional Check with the computer automation software for compatibility E Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message
Four-digit account number Always char “A” Two-digit alarm zone code Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
25
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.25 Telim (Message Type n) Telim Example
Table 29: # 1 2 3-4 5 6 7-12 13 14 15-32 33
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
h
n
R
R
L
s
A
A
A
A
A
A
s
E
T
T
Z
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
t
Z
Telim (Message Type n) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number Space E TTZZZZZZZZZZZZ Trailer Character
Description Optional Check with the computer automation software for compatibility n Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message One space Six digit account number One space Event code Input line number Typically, HEX 14
4.1.26 Text Message (Message Type 3) Type 3 Example
Table 30: # 1 2 3-4 5 6-21 22
26
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
h
3
r
r
l
P
R
I
N
T
E
R
13
14
15
16
17
18
19
20
21 22
v
v
.
v
v
t
Text Message (Message Type 3) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Message Text Trailer Character
Description Optional Check with the computer automation software for compatibility 3 Receiver gateway number from 01 to 99 Line number fixed at 1. Sixteen characters in length Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.1.27 Varitech FSK 4-1 (Message Type 1) Varitech FSK 4-1 D6500 Byte Description Example 1 2 3 4 5 6
h Table 31: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22
1
r
r
l
s
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
s
s
s
s
s
a
a
a
a
s
E
s
s
s
X
t
Varitech FSK 4-1 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character
Description Optional, check with the computer automation software for compatibility 1 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Four digit account number One space Event code Three spaces Zone number Typically, HEX 14
4.1.28 Varitech FSK 4-2 (Message Type 1) Varitech FSK 4-2 D6500 Byte Description Example 1 2 3 4 5 6
h Table 32: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22
1
r
r
l
s
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
s
s
s
s
s
a
a
a
a
s
E
s
s
X
Y
t
Varitech FSK 4-2 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character
Description Optional Check with the computer automation software for compatibility 1 Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Four digit account number One space Event code Two spaces Zone number Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
27
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.1.29 VONK (Message Type V) D6500 Byte Description VONK Example
Table 33: # 1
1 h
2 V
3 r
4 r
6 A
7 A
8 1
9 2
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3 4 5 6 7 8 9 A B C D E F G t
VONK (Message Type V) Byte Description
6-7 8-23
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number Zone status
24
Trailer Character
2 3-4 5
5 l
Description Optional Check with the computer automation software for compatibility V Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Two digit account number Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is Open, 1 to G appears in this position. Typically, HEX 14
4.1.30 X-SIA Text (Message Type S) X-SIA Example
Table 34: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22-34 35 36-37 38 39-41 42
28
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
S
r
r
l
[
#
a
a
a
a
|
E
M
M
Z
Z
Z
Z
*
`
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
T
T
T
T
T
T
T
T
T
T
T
T
‘
N
M
/
*
*
*
t
T
X-SIA Text (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E MM ZZZZ * ‘ TT…T ‘ NM / *** Trailer Character
Description Optional, check with the computer automation software for compatibility S Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Open bracket # Up to sixteen digits can be used in the account number Separator, indicates more data positions after account number SIA block code SIA event code Zone number Text identifier Quotation mark (single) 13 character text string Qutotation mark (single) Unit field characters Separator Next block of data Typically, HEX 14
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
.
4.2
SIA Mode Messages
Use the SIA mode for central station monitoring. 4.2.1 Acron Super Fast (Message Type 9) Acron Super Fast Example
Table 35:
Acron Super Fast (Message Type 9) Byte Description
Title L CRC Message Type sequence# receiver# line# (Line/Group #) account#
Figure 6:
SIA Mode Description [#aaaa|CCCCCCCC]
Description Standard line feed character Cyclical redundancy check number 9 The message sequence number, the valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits.
Message sent to printer
mm/ddshh:mmsLxxsACNsACCTsaaaa+++sACCsa aaasCCCCsCCCC For lines that are grouped, Gxx appears instead of Lxx. Table 36:
Characters ACN Lxx Gxx
Acron Super Fast (Message Type 9) Printer Output Description Acron Super Fast format Line number Grouped line numbers
Bosch Security Systems | 1/05 | 4998122703D
29
D6600 | Computer Interface Manual | 4.0 4.2.2
Computer Communication Protocols
Ademco Contact-ID (Message Type a)
Contact-ID Example
Table 37:
SIA Mode Description [#aaaa|18QXYZGGCCC]
Ademco Contact-ID (Message Type a) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# 18 Q XYZ GG CCC
Figure 7:
Description Standard line feed character Cyclical redundancy check number a The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Ademco Contact-ID format number Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 = Previous event Class code and event code (refer to Appendix A: Contact ID Event Code Classifications on page 53) Group number Zone codes or User ID
Message sent to printer
Table 38:
Ademco Contact-ID (Message Type a) Printer Output
mm/ddshh:mmsLxxsCIDsACCTsaaaa+++sACCsa aaasNNNsEVENT=XYZsG=GGsC=CCC For lines that are grouped, Gxx appears instead of Lxx.
30
Characters CID Gxx Lxx NNN
Description Contact-ID format Grouped Line numbers Line number If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing If Q = 6, print “OLD” for old messages and events.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0 . 4.2.3
Computer Communication Protocols
Ademco 4-1 Express (Message Type b)
4-1 Express Example
Table 39:
SIA Mode Description [#aaaa|X]
Ademco 4-1 Express (Message Type b) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X
Figure 8:
Description Standard line feed character Cyclical redundancy check number b The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Zone number
Message sent to printer
mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X For lines that are grouped, Gxx appears instead of Lxx. Table 40:
Characters E41 Lxx: Gxx
Ademco 4-1 Express (Message Type b) Printer Output Description Ademco 4-1 Express format Line number Grouped line numbers
Bosch Security Systems | 1/05 | 4998122703D
31
D6600 | Computer Interface Manual | 4.0 4.2.4
Computer Communication Protocols
Ademco 4-2 Express (Message Type c)
4-2 Express Example
Table 41:
SIA Mode Description [#aaaa|XY]
Ademco 4-2 Express (Message Type c) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# XY
Figure 9:
Description Standard line feed character Cyclical redundancy check number c The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code and Zone number
Message sent to printer
mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY For lines that are grouped, Gxx appears instead of Lxx. Table 42:
Characters E42 Lxx: Gxx
32
Ademco 4-2 Express (Message Type c) Printer Output Description Ademco 4-2 Express format Line number Grouped line numbers
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0 . 4.2.5
Computer Communication Protocols
Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) SCANCOM 5-8-1, 6-8-1 - available upon request
High Speed Example
Table 43:
SIA Mode Description [#aaaaaa|CC CCsCCCCsC]
Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s C
Description Standard line feed character Cyclical redundancy check number f The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4 One space Channels 5 to 8 One space Supervisory channel
Figure 10: Message sent to printer
Table 44:
Ademco High Speed, 4-8-1 (Message Type f) Printer Output
mm/ddshh:mmsLxxsHGHsACCTsaaaaaa+++sACC saaaaaasCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
Bosch Security Systems | 1/05 | 4998122703D
Characters HGH Lxx: Gxx
Description Ademco High Speed format Line number Grouped line numbers
33
D6600 | Computer Interface Manual | 4.0 4.2.6
ADT SIA (Message Type )
ADT SIA Example
Table 45:
SIA Mode Description [#aaaa|data]
ADT SIA (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# E damm-dd-yytihh:mm:ss Data
4.2.7
Description Standard line feed character Cyclical redundancy check number 09 hex The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. Event Code (refer to Appendix G ADT SIA Report Codes on page 152) Date and time This field contains message data codes such as event type, area number, point number, identification number.
Caller ID (Message Type )
SIA Example
Table 46:
SIA Mode Description [&TTTTTTTTTTTTTTTT]
Caller ID (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) & T
34
Computer Communication Protocols
Description Standard line feed character Cyclical Redundancy Check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Origin ID Block Up to 16-digit Caller ID
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0 . 4.2.8
CFSK (Message Type I)
CFSK Example
Table 47:
SIA Mode Description [#aaaaaa|TTEE]
CFSK (Message Type I) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # TT EE
4.2.9
Computer Communication Protocols
Description Standard line feed character Cyclical redundancy check number I (Capital I) The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits. Event code Zone/User ID
Common Formats (Message Type )
SIA Example
Table 48:
SIA Mode Description [#aaaaaaaaaaaaaaaa|data]
Common Formats (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# Data
Description Standard line feed character Cyclical Redundancy Check number 09 hex The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. This field contains message data codes such as event type, area number, point number, identification number, etc
The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Radionics Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.
Bosch Security Systems | 1/05 | 4998122703D
35
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.10 DNIS/ANI (Message Type N) SIA Example
Table 49:
SIA Mode Description [#0000|Dddddddddddd&aaaaaaaaaa]
DNIS/ANI (Message Type N) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# D DNIS number (d) ANI identifier (&) ANI number (a)
Description Standard line feed character Cyclical redundancy check number N The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Fixed at 0000 DNIS identifier DNIS number, up to 11 digits ANI identifier ANI number, up to 11 digits
Figure 11: Message sent to printer MM/DDsHH:MMsLxxsDNISsddddddddddd+++sAN Isaaaaaaaaaaa
36
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.11 DSC 4-3 (Message Type d) DSC4-3 Example
Table 50:
SIA Mode Description [#aaaa|XYY]
DSC 4-3 (Message Type d) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X YY
Description Standard line feed character Cyclical redundancy check number d The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code number Zone number
Figure 12: Message sent to printer
Table 51:
DSC 4-3 (Message Type d) Printer Output
mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XY Y+++sACCsaaaaseeeeeeeesiisnnn For lines that are grouped, Gxx appears instead of Lxx.
Table 52:
Event Code Table
Code Number
Message
1 2 3 4 5 6 7 8 9 0 B C D E F
Alarm
Close Open Alarm
Restore Trouble CloseGrp OpenGrp Bypass UnBypass Cancel
Characters DSG Lxx: Gxx
Table 53: Event Characters A A A C O A A A R T C O B H O
Bosch Security Systems | 1/05 | 4998122703D
Characters ii nnn eeeeeeee
Description DSC/Sur-Gard 4-3 format Line number Grouped line numbers
Printer Output Codes Description ZN=Zone number - ID=User ID Zone/User number Up to eight-character event type, right justified - ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL
37
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.12 FBI Super Fast (Message Type F) FBI Super Fast Example
Table 54:
SIA Mode Description [#aaaa|TZZE]
FBI Super Fast (Message Type F) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# T ZZ E
Description Standard line feed character Cyclical redundancy check number F The message sequence number. The valid sequence number range is 0001 to 9999 The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600 The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages The communicator's account number has four digits. Zone type Zone number Event type
Figure 13: Message sent to printer
Table 55:
mm/ddshh:mmsLxxsFBIsACCTsaaaasTZZE+++s ACCsaaaastttttttttseeeeeeeesiisnnn For lines that are grouped, Gxx appears instead of Lxx.
Table 56: Code 1 2 3 4 5 6 7 8 9 0 B C D E F
38
Event Code Table Zone/Event Type Fire Panic Burglary Medical Auxiliary Bypass Inactive Eight Nine Zero Opening Closing Abort Restore Trouble
FBI Super Fast (Message Type F) Printer Output
Characters FBI Lxx: Gxx
Description FBI Super Fast format Line number Grouped line numbers
Table 57:
Printer Output Codes
Characters ii nnn ttttttttt
eeeeeeee
Description ZN=Zone number - ID=User ID Zone/User number Up to nine-character zone type, right justified FIRE, PANIC, BURGLARY, MEDICAL, AUXILIARY Up to eight-character event type, left justified ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.13 ITI (Message Type I) ITI Example
Table 58:
SIA Mode Description [#aaaaa|GIZZEWN]
ITI (Message Type I) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# G I ZZ E W N
Description Standard line feed character Cyclical redundancy check number I (Captial I) The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Group number O/C User ID Zone number Condition code Protection level was Protection level now
4.2.14 Link Test (Message Type ) Link Test Example
SIA Mode Description []
The D6600 can automatically generate this message at the preprogrammed intervals. Table 59:
Link Test (Message Type ) Description
Title LF CRC Message Type sequence# receiver#
Description Standard line feed character Cyclical redundancy check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600.
Bosch Security Systems | 1/05 | 4998122703D
39
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.15 RB2000 (Message Type R) Description RB2000 Example
Table 60:
SIA Mode Description []
RB2000 (Message Type R) Byte Description
Title LF CRC R sequence# Receiver# line# CR
Description Standard line feed character, hex 0A Cyclical redundancy check number ASCII R, Message Type R for RB2000 format The message sequence number. The valid sequence number range: 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. VDS message sent as a hex string, the receiver extracts the alarm type Hex 0D
Figure 14: Single message sent to Printer
Table 61:
RB2000 (Message Type R) Printer Output
MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA Figure 15: Multiple messages sent to printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA 1 +++ RB2000_EVENT_RAW_DATA 2 ... +++ RB2000_EVENT_RAW_DATA n
40
Characters
Description
MM/DDsHH:MM RB2 Lxx ACCT xxxxxxxxxxxx
Date and time RB2000 format Line number Subscriber number, up to 12 characters(hex) The raw data of RB2000 event
RB2000_EVENT_RAW _DATA RB2000_EVENT_RAW _DATA1 RB2000_EVENT_RAW _DATA 2 RB2000_EVENT_RAW _DATA n
The raw data of RB2000 event 1 The raw data of RB2000 event 2 The raw data of RB2000 event n
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.16 Robofon (Message Type j) Robofon Example
Table 62:
SIA Mode Description [#aaaaaa|EE]
Robofon (Message Type j) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EE
Description Standard line feed character Cyclical redundancy check number j The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code
4.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) 4-16-1 Example
Table 63:
SIA Mode Description [#aaaaaa|CCCCsCCCCsCCCCsCCCCsC]
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account# CCCC s CCCC s CCCC s CCCC s C
Description Standard line feed character Cyclical redundancy check number g The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4 One space Channels 5 to 8 One space Channels 9 to 12 One space Channels 13 to 16 One space Supervisory channel
Bosch Security Systems | 1/05 | 4998122703D
41
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
Figure 16: Message sent to printer
Table 64:
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa+++sACC saaaaaasCCCCsCCCCsCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Printer Output
Characters SCN Lxx: Gxx
Description Scancom Line number Grouped line numbers
4.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) 4-24-1 Example
Table 65:
SIA Mode Description [#aaaaaa|CCCCsCCCCs CCCCs CCCCsCCCCsCCCCsC]
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s CCCC s CCCC s CCCC s CCCC s C
Description Standard line feed character Cyclical redundancy check number h The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits Channels 1 to 4 One space Channels 5 to 8 One space Channels 9 to 12 One space Channels 13 to 16 One space Channels 17 to 20 One space Channels 21 to 24 One space Supervisory channel
Figure 17: Message sent to printer
Table 66:
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa +++sACCsaaaasCCCCsCCCCsCCCCsCCCC ++++++++++++++CCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
42
Characters SCN Lxx: Gxx
Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Printer Output Description Scancom Line number Grouped line numbers
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.19 Seriee DTMF (Message Type l) Seriee DTMF Example
Table 67:
SIA Mode Description [#aaaa|*data]
Seriee DTMF (Message Type l) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # * Data
Description Standard line feed character Cyclical redundancy check number l (lowercase L) The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data separator DTMF Seriee Data
4.2.20 Seriee FSK (Message Type k) Seriee FSK Example
Table 68:
SIA Mode Description [#aaaaa|EZZ]
Seriee FSK (Message Type k) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account # E ZZ
Description Standard line feed character Cyclical redundancy check number k The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code Zone number
Bosch Security Systems | 1/05 | 4998122703D
43
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.21 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example
Table 69:
SIA Mode Description
Sescoa Super Speed (Message Type 7) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# I AA C
Description Standard line feed character Cyclical redundancy check number 7 The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code Two- digit zone code or the first two digits user code. Space if zone report, or the last digit user code
Figure 18: Message sent to printer
Table 70:
Sescoa Super Speed (Message Type 7) Printer Output
mm/ddshh:mmsLxxSESsACCTsaaaa +++sACCsaaaasEEEseeeeeeeeeeeeee For lines that are grouped, Gxx appears instead of Lxx.
44
Characters SES Lxx Gxx aaaa EEE eeeeeeeeeeeeee
Description SESCOA Super Speed format Line number Grouped line numbers Account code SESCOA Super Speed format event Up to 14-characters of event description
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.22 Silent Knight FSK() (Message Type ) Silent Knight FSK0 Example
Table 71:
SIA Mode Description [#aaaa|data]
Silent Knight FSK0 (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data
Description Standard line feed character Cyclical redundancy check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data
4.2.23 Silent Knight FSK1 (Message Type m) Silent Knight FSK1 Example
Table 72:
SIA Mode Description [#aaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]
Silent Knight FSK1 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ
Description Standard line feed character Cyclical redundancy check number m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character.
Bosch Security Systems | 1/05 | 4998122703D
45
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
Optional Silent Knight FSK1 (Message Type m) If Menu Item 2.5.16 in the D6600 Receiver is equal to 1, the following output is used. Silent Knight FSK1 Example
Table 73:
SIA Mode Description [#aaaa|ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]< CR>
Optional Silent Knight FSK1 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z Z
Table 74:
Description Standard line feed character Cyclical redundancy check number m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has two digits. The quote (“) is the separate character.
Silent Knight FSK1 Optional Outputs
Report Code
Description
To Automation 2 5 16 = 0(EEZZ)
2 5 16 = 1(ZZ)
00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 81 to 89
Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09
PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x
00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89
46
Note
x = 1 to 8 x = 0 to 9 x = 0 to 9
x = 1 to 9 x = 0 to 9 x = 1 to 8
x = 1 to 9
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. Table 74:
Silent Knight FSK1 Optional Outputs (continued)
Report Code
Description
To Automation
90 91 to 99
Opening Opening 01 to 09
OP00 OP0x
Note 90 91 to 99
4.2.24 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example
Table 75:
SIA Mode Description [#aaaaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]
Silent Knight FSK2 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ
Description Standard line feed character Cyclical redundancy check number m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character.
Bosch Security Systems | 1/05 | 4998122703D
47
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.25 Silent Knight FSK80 (Message Type E) Silent Knight FSK80 Example
Table 76:
SIA Mode Description [#AAAA|NBAXY]
Silent Knight FSK80 (Message Type E) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # NBA
Description Standard line feed character Cyclical redundancy check number E The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Alarm event
Figure 19: Message sent to printer MM/DDsHH:MMsLxxsSFKsACCTsAAAA +++ACCTsAAAAsALARM_ZNs1 +++ACCTsAAAAsALARM_ZNs2 +++ACCTsAAAAsALARM_ZNs3 +++ACCTsAAAAsALARM_ZNs4 +++ACCTsAAAAsALARM_ZNs5 +++ACCTsAAAAsALARM_ZNs7 +++ACCTsAAAAsALARM_ZNs8 +++ACCTsAAAAsALARM_ZNs9
Table 77:
Characters MM/DDsHH:MM SFK Lxx AAAA s
48
Silent Knight FSK80 Printer/LCD output Description Date and time SFSK80 format Line number The communicator's account number has four digits. Space
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.26 Telim (Message Type n) Telim Example
Table 78:
SIA Mode Description [#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ]
Telim (Message Type n) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EETTZZZZZZZZZZZZZZZZ ZZ
Description Standard line feed character Cyclical redundancy check number n The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. The event type and input line number
4.2.27 Varitech FSK 4-1 (Message Type ) Varitech FSK 4-1 Example
Table 79:
SIA Mode Description [#aaaa|data]
Varitech FSK 4-1 (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# data
Description Standard line feed character Cyclical redundancy check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99 The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and 1-digit zone number
Bosch Security Systems | 1/05 | 4998122703D
49
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
4.2.28 Varitech FSK 4-2 (Message Type ) Varitech FSK 4-2 Example
Table 80:
SIA Mode Description [#aaaa|data]
Varitech FSK 4-2 (Message Type ) Byte Description
Title LF CRC Message sequence# receiver# line# (Line/Group #) account # data
Description Standard line feed character Cyclical redundancy check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and two-digit zone number.
4.2.29 VONK (Message Type V) VONK Example
Table 81:
VONK (Message Type V) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data
50
SIA Mode Description [#aa|123456789ABCDEFG]
Description Standard line feed character Cyclical redundancy check number V The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has two digits. Status of zones 1 to 16. If the zone is closed, a “.” (Period) appears in this position. If the zone is open, any digit from 1 to G appears in this position.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | 4.0
Computer Communication Protocols
. 4.2.30 X-SIA text (Message Type ) X-SIA Example
Table 82:
SIA Mode Description [#aaaa|EMMZZZZ*'TTTTTTTTTTTTT' NM/***]
X-SIA text (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # E MM ZZZZ * ` TT…TTT ‘ NM / ***
Description Standard line feed character Cyclical redundancy check number The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600 The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to 16 digits. SIA block code SIA event code Zone number Text identifier Single quote 13 character text string Single quote Unit field characters Separator Next data
Figure 20: Message sent to printer MM/DDsHH:MMsLxxsSIAsACCTsAAAA+++sEMMZZ ZZ*'TTTTTTTTTTTTT'NM+++sEMMZZZZ*'TTTTT TTTTTTTT'NM
Bosch Security Systems | 1/05 | 4998122703D
Table 83:
X-SIA Printer/LCD output
Characters MM/DDsHH:MM Lxx SIA AAAA E MM ZZZZ * ‘ TTT…T ‘ NM
Description Date and time Line number SIA format Account code SIA block code SIA event code Zone number Text identifier Single quote 13 character text string Single quote Unit field characters
51
D6600 | Computer Interface Manual | 4.0
4.3
Computer Communication Protocols
Input Command Processing
Input devices, such as automation systems, send the commands described in Table 84 to the receiver. If the receiver does not recognize a command, it generates a REJECT COMMAND message, prints at connected printers, and sends an ASCII text message to the automation port. The CPU programming in Menu Item 2.2.4 of the D6600 Receiver must be set to 1 to use input commands. Table 84:
ASCII Text Message to Automation Port
Set Time
The automation system, or other device, sends the command shown below to set the time at the D6600 provided that the D6600 is programmed to synchronize the time and date with the automation system !Thhmm D6650 Mode: [CSThhm SIA m] Mode: hh - hours (24 hour format) mm - minutes The automation system, or other device, sends the command shown below to set the date at the D6600 provided that the D6600 is programmed to synchronize the time and date with the automation system !Dmmddyy D6650 Mode: [CSDmmd SIA dyy] Mode: mm - month, dd - day, yy – year The automation system, or other device, sends the command shown below to stop a two way audio session on the line specified !Kn D6650 Mode: [CLKnn] SIA Mode: nn - line card number, 01-32 h3rrlsREJECTsCOMMANDsst D6650 Mode: [RE Mode: JECT COMMAND]
Set Date
Stop Two Way Audio
Reject Command
52
Table 85 shows the D6500 and SIA automation output formats for these input commands. Table 85:
Set Time Set Date Stop Two Way Audio
Input Command Output Messages
D6500 Mode h1rrssssss ssssssXss2 t h1rrssssss ssssssXss5 1t h1rrssssss ssssssXss5 2t
SIA Mode [NJT]
Printer Output TIME SET
[NJD]
DATE SET
[CLK]
TWO WAY AUDIO STOP STOP
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications .
Appendix A: Contact ID Event Code Classifications Figure 21: Contact ID format 1
2
3
4
5
1234 E 123 01 123 1234-
Customer (Subscriber Account Number) Event Qualifier - E = New Event, R = Restore Event Code - refer to Section A.1 Event Codes Partition Number, 00 to 08 (always 00 for nonpartitioned panels) 5 - Zone ID number* - reporting the alarm (001 to 999) or user number for open or close reports. * System status messages, such as AC Loss and Low Battery, are Zone ID 000. Table 86: #
Event Codes
Event Type
Medical: 100 Medical 101 Pendant Transmitter 102 Fail to report in Fire Alarms: 110 Fire 111 Smoke w/Verification 112 Combustion 113 Waterflow 114 Heat 115 Pull Station 116 Duct 117 Flame 118 Near Alarm Panic Alarms: 120 Panic Alarm 121 Duress 122 Silent 123 Audible 124 Duress-Access Granted 125 Duress-Egress Granted
Zone Emerg-Personal Emergency-# Emerg-Personal Emergency-# Emerg-Fail to check in-# Fire-Fire Alarm-# Fire-Fire Alarm-# Fire-Combustion-# Fire-Water Flow-# Fire-Heat Sensor-# Fire-Pull Station-# Fire-Duct Sensor-# Fire-Flame Sensor-# Fire-Near Alarm-# Panic-Panic-# Panic-Duress-User # Panic-Silent Panic-# Panic-Audible Panic-# Panic-Duress Access Grant-# Panic-Duress Egress Grant-#
Bosch Security Systems | 1/05 | 4998122703D
Table 86:
#
Event Codes (continued)
Event Type
Burglar Alarms: 130 Burglary 131 Perimeter 132 Interior 133 24 HR Burg (Aux) 134 Entry/Exit 135 Day/Night 136 Outdoor 137 Tamper 138 Near Alarm 139 Intrusion Verifier General Alarms: 14 General Alarm 0 14 Polling Loop 1 Open 14 Polling Loop 2 Short (AL) 14 Expansion Mod 3 Failure 14 Sensor Tamper 4 14 Expansion Module 5 Tamper 14 Silent Burg 6
Zone Burg-Burglary-# Burg-Perimeter-# Burg-Interior-# Burg-24 Hour-# Burg-Entry/Exit-# Burg-Day/Night-# Burg-Outdoor-# Burg-Tamper-# Burg-Near Alarm-# Burg-Intrusion Verifier-# Alarm-General Alarm-# Alarm-Polling Loop Open Alarm-Polling Loop Short Alarm-Exp. Module Tamper-# Alarm-Sensor Tamper-# Alarm-Exp. Module Tamper-# Alarm-Silent Burglary-#
53
D6600 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications
Table 86:
#
Event Codes (continued)
Event Type
24 Hour Non-Burglary: 150 24 Hour (Auxiliary 151 Gas Detected 152 Refrigeration 153 Loss of Heat 154 Water Leakage 155 Foil Break 156 Day Trouble Low Bottled Gas 157 Level 158 High Temp 159 Low Temp 161 Loss of Air Flow Carbon Monoxide 162 Detected 163 Tank Level Fire Supervisory: 200 Fire Supervisory Low Water 201 Pressure 202 Low CO2 Gate Valve 203 Sensor 204 Low Water Level 205 Pump Activated 206 Pump Failure System Troubles: 300 System Trouble 301 AC Loss 302 Low System Batt RAM Checksum 303 Bad ROM Checksum 304 Bad 305 System Reset 306 307 308 309 310 311 312 313
54
Panel Prog Change Self-Test Failure System Shutdown Battery Test Fail Ground Fault Battery Missing Power Supply Overcurrent Engineer Reset
Zone Alarm-24 Hr. Non-Burg-# Alarm-Gas Detected-# Alarm-Refrigeration-# Alarm-Heating System-# Alarm-Water Leakage-# Trouble-Foil Break-# Trouble-Day Zone-# Alarm-Low Gas Level-# Alarm-High Temperature-# Alarm-Low Temperature-# Alarm-Air Flow-# Alarm-Carbon Monoxide-# Trouble-Tank Level-# Super.-Fire Supervisory-# Super.-Low Water Pressure-# Super.-Low CO2-# Super.-Gate Valve-# Super.-Low Water Level-# Super.-Pump Activation-# Super.-Pump Failure-# Trouble-System Trouble Trouble-AC Power Trouble-Low Battery Trouble-Bad RAM Checksum (Restore not applicable) Trouble-Bad ROM Checksum (Restore not applicable) Trouble-System Reset (Restore not applicable) Trouble-Programming Changed (Restore not applicable) Trouble-Self Test Failure Trouble-System Shutdown Trouble-Battery Test Failure Trouble-Ground Fault-# Trouble-Battery Missing Trouble-Pwr. Supp. Overcur.-#
Table 86:
#
Event Codes (continued)
Event Type
Sounder/Relay Troubles: 320 Sounder/Relay 321 BELL 1 322 BELL 2 323 Alarm Relay 324 Trouble Relay 325 Reversing Relay Notification 326 Appliance CKT. #3 Notification 327 Appliance CKT. #4 System Peripheral Troubles: 330 System Peripheral 331 Polling Loop Open 332 Polling Loop Short 333 Exp. Module Failure 334 Repeater Failure Local Printer Paper 335 Out 336 Local Printer Failure 337 Exp. Mod. DC Loss 338 Exp. Mod. Low bat 339 Exp. Mod. Reset 341 Exp. Mod. Tamper Exp. Module AC 342 Loss Exp. Module Self 343 Test Fail RF Rcvr Jam Detect 344 # Communication Troubles: 350 Communication 351 352 353 354 355 356 357
Telco 1 Fault Telco 2 Fault LR Radio Xmitter Fault Failure To Communicate Loss of Radion Super. Loss of Central Polling LRR XMTR. VSWR
Zone Trouble-Sounder/Relay-# Trouble-Bell/Siren #1 Trouble-Bell/Siren #2 Trouble-Alarm Relay Trouble-Trouble Relay Trouble-Reversing Relay Trouble-Notification Appl. Ckt#3 Trouble-Notification Appl. Ckt#4 Trouble-Sys. Peripheral-# Trouble-Polling Loop Open Trouble-Polling Loop Short Trouble-Exp. Module Fail-# Trouble-Repeater Failure-# Trouble-Printer Paper Out Trouble-Local Printer Trouble-Exp. Mod. DC Loss-# Trouble-Exp. Mod. Low Batt-# Trouble-Exp. Mod. Reset-# Trouble-Exp. Mod. Tamper-# Trouble-Exp. Module AC Loss-# Trouble-Exp. Self-Test Fail-# Trouble-RF Rcvr Jam Detect# Trouble-Communication Failure Trouble-Phone line #1 Trouble-Phone line #2 Trouble-Radio Transmitter Trouble-Fail to Communicate Trouble-Radio Supervision Trouble-Central Radion Polling Trouble-Radio Xmitter. VSWR-#
Status-Engineer Reset-User # (Restore not applicable)
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 86:
#
Event Codes (continued)
Event Type
Protection Loop: 370 Protection Loop Protection Loop 371 Open Protection Loop 372 Short 373 Fire Trouble 374 Exit Error (By User) 375 Panic Zone Trouble Hold-Up Zone 376 Trouble Sensor: Sensor TRBL380 Global Loss Of 381 Supervision 382 Loss Of Supervisn 383 384 385 386 387 388 389 391 392 393
Sensor Tamper RF Low Battery Smoke Hi Sens. Smoke lo sens. Intrusion hi sens. Intrusion lo sens. Det. Self test fail Sensor Watch Failure Drift Comp. Error Maintenance Alert
Zone Trouble-Protection Loop-# Trouble-Prot. Loop Open-# Trouble-Prot. Loop Short-# Trouble-Fire Loop-# Alarm-Exit Error-# Trouble-PA Trouble-# Trouble-Hold-Up Trouble-#
Table 86:
#
Event Codes (continued)
Event Type
Open/Close: 400 Open/Close Open/Close By 401 User 402 Group O/C Automatic 403 Open/Close 404 Late to O/C 405 Deferred O/C 406 407
Trouble-Sensor Trouble-# 408
Cancel (By User) Remote Arm/Disarm Quick Arm
Trouble-RF Sensor Super.-# 409 Trouble-RPM Sensor Super.# Trouble-Sensor Tamper-# Trouble-RF Sensor Battery-# Trouble-Smoke Hi Sens.-# Trouble-Smoke Lo Sens.-# Trouble-Intrusion Hi Sens.-# Trouble-Intrusion Lo Sens.-# Trouble-Sensor Test Fail-# Trouble-Sensor Watch Fail-# Trouble-Drift Comp. Error-# Trouble-Maintenance Alert-#
Bosch Security Systems | 1/05 | 4998122703D
441
Keyswitch Open/Close Armed Stay
442
Keyswitch Armed Stay
450
Exception O/C
451
Early O/C
452
Late O/C
153
Failed to Open
454
Failed to Close
455
Auto-Arm Failed
456 457 458
Partial Arm Exit Error (User) User on Premises
459
Recent Close
461
Wrong Code Entry
462
Legal Code Entry
463
Re-arm after Alarm
Zone Opening/Closing Opening-User #/Closing-User # Closing-Group User # Opening-Automatic/ClosingAutomatic Opening-Late/Closing-Late Event & Restore Not Applicable Opening-Cancel Opening-Remote/ClosingRemote Event not applicable for opening/closing-Quick Arm Opening-Keyswitch/ClosingKeyswitch Opening-Armed Stay/ClosingArmed Stay Opening-Keysw. Arm Stay/Opening-Keysw. Arm Stay Opening-Exception/ClosingException Opening-Early/Closing-EarlyUse r# Opening-Late/Closing-LateUser # Trouble-Fail to open (Restore not applicable) Trouble-Fail to Close (Restore not applicable) Trouble-Auto Arm Failed (Restore not applicable) Closing-Partial arm-User # Closing-Exit Error-User # Opening-User on Prem. –User # Trouble-Recent Close-User # (Restore not applicable) Access-Wrong Code entry (Restore not applicable) Access-Legal Code entry-user # (Restore not applicable) Status-Re Arm After AlarmUser # (restore not applicable)
55
D6600 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications
Table 86:
#
Event Codes (continued)
Event Type
Open/Close: Auto Arm Time 464 Extended 465
Panic Alarm Reset
Remote Access: Callback 411 Requested Success412 Download/access Unsuccessful 413 Access 414 System Shutdown 415 Dialer Shutdown 416 Successful Upload Access Control: 421 Access Denied
423 424
Access Report by User Forced Access Egress Denied
425
Egress Granted
422
Access Door Propped Open Access Point DSM 427 Trouble Access Point RTE 428 Trouble Access Program 429 Mode Entry Access Program 430 Mode Exit Access Threat 431 Level Change Access 432 Relay/Trigger Fail 433 Access RTE Shunt 434 Access DSM Shunt System Disables: Access Reader 501 Disable 426
56
Zone Status-Auto Arm Time Ext.User # (Restore not applicable) Status-PA Reset (Restore not applicable) Remote-Callback Requested (Restore not applicable) Remote-Successful Access (Restore not applicable) Remote-Unsuccessful Access (Restore not applicable) Remote-System Shutdown Remote-Dialer Shutdown Remote-Successful Upload (Restore not applicable) Access-Access Denied-User # (Restore not applicable) Access-Access Gained-User # (Restore not applicable) Panic-Forced Access-# Access-Egress Denied (Restore not applicable) Access-Egress Granted (Restore not applicable) Access-Door Propped Open# Access-ACS Point DSM Trbl.# Access-ACS Point RTE Trbl.# Access-ACS Prog. Entry-User # (Restore not applicable) Access-ACS Prog. Exit-User # (Restore not applicable) Access-ACS Threat Level Chg. Access-ACS Relay/Trig. Fail# Access-ACS RTE Shunt-# Access-ACS DSM Shunt-#
Table 86:
#
Event Codes (continued)
Event Type
Sounder/Relay Disables: Sounder/Relay 520 Disable 521 Bell 1 Disable 522 Bell 2 Disable Alarm Relay 523 Disable Trouble Relay 524 Disable Reversing Relay 525 Disable Notification 526 Appliance Ckt #3 Notification 527 Appliance Ckt #4 System Peripheral Disables: 531 Module Added 532
Module Removed
Communication Disables: 551 Dialer Disabled Radio Xmitter 552 Disabled Remote 553 Upload/Download Bypasses: Zone/Sensor 570 Bypass 571 Fire Bypass 24 Hour Zone 572 Bypass 573 Burg. Bypass 574 Group Bypass 575 Swinger Bypass 576 Access Zone Shunt Access Point 577 Bypass
Zone Disable-Sounder/Relay-# Disable-Bell/Siren #1 Disable-Bell/Siren #2 Disable-Alarm Relay Disable-Trouble Relay Disable-Reversing Relay Disable-Notification Appl. Ckt #3 Disable-Notification Appl. Ckt #4 Super.-Module Added (Restore not applicable) Super.-Module Removed (Restore not applicable) Disable-Dialer Disable Disable-Radio Disable Disable-Rem. Up/Download Disable Bypass-Zone Bypass-# Bypass-Fire Bypass-# Bypass-24 Hour Bypass-# Bypass-Burg. Bypass-# Bypass-Group Bypass-User # Bypass-Swinger Bypass-# Access-ACS Zone Shunt-# Access-ACS Point Bypass-#
Disable-Access Rdr. Disable#
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 86:
#
Event Codes (continued)
Event Type
Test/Misc.: 601 Manual Test 602
Periodic Test
603
Periodic RF Xmission Fire Test Status Report To Follow Listen-In To Follow
604 605 606 607 608 609
Walk-Test Mode System Trouble Present Video XMTR Active
611
Point Tested OK
612
Point Not Tested
Intrusion Zone Walk Tested Fire Zone Walk 614 Tested Panic Zone Walk 615 Tested 616 Service Request Event Log: 621 Event Log Reset 613
622
Event Log 50% Full
623
Event Log 90% Full
624
Event Log Overflow
625
Time/Date Reset
626
Time/Date Inaccurate Program Mode Entry Program Mode Exit
627 628
Zone Test-Manually Triggered (Restore not applicable) Test-Periodic (Restore not applicable) Test-Periodic Radio (Restore not applicable) Test-Fire Walk Test-User # Test-Fire Walk-User # Listen-Listen-In Active (Restore not applicable) Test-Walk Test Mode-User # Test-System Trouble Present (Restore not applicable) Listen-Video Xmitter Active (Restore not applicable) Test-Point Tested OK-# (Restore not applicable) Test-Point Not Tested-# (Restore not applicable) Test-Intrn Zone Walk Test-# (Restore not applicable) Test-Fire Zone Walk Test-# (Restore not applicable) Test-PA Zone Walk Test (Restore not applicable) Trouble-Service Request
Table 86:
#
Event Codes (continued)
Event Type
Scheduling: 630 Schedule Change 631 632
Exception Sched. Change Access Schedule Changes
Zone Trouble-Schedule Changed (Restore not applicable) Trouble-Esc. Sched. Changed (Restore not applicable) Trouble-Access Sched. Changed (Restore not applicable)
Personnel Monitoring: Senior Watch 641 Trouble-Senior Watch Trouble Trouble Latch-key Status-Latch-key Super-User 642 Supervision # (Restore not applicable) Special Codes: 750These codes are used by Protection ONLY & can be 789 assigned any unique non-standard Event code, which Pro 1 will be tracking.
Trouble-Event Log Reset (Restore not applicable) Trouble-Event Log 50% Full (Restore not applicable) Trouble-Event Log 90% Full (Restore not applicable) Trouble-Event Log Overflow (Restore not applicable) Trouble-Time/Date Reset-User # (Restore not applicable) Trouble-Time/Date Invalid Trouble-Program Mode Entry (Restore not applicable) Trouble-Program Mode Exit (Restore not applicable)
Bosch Security Systems | 1/05 | 4998122703D
57
D6600 | Computer Interface Manual | Appendix B: Internal Messages
Appendix B: Internal Messages Table 87:
Internal Messages
#
Internal Messages
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
Acknowledge † Keypad Operation † Service Required Set Time Battery Missing † Battery Present Battery Bad Battery Restore AC Fail AC Restore † Paper In † Paper Out † Local Parameter Program In Local Parameter Program † Successful † Local Software Program In Local Software Program † Successful † Local Program Failure † Local Program Denied Remote Parameter Program In Remote Parameter Program Successful Remote Software Program In Remote Software Program Successful Remote Program Failure † Remote Program Denied † Printer On Line † Printer Off Line External PRT Error External PRT Restore † Internal PRT Error † Internal PRT Restore Busy Seconds COM3 Error COM3 Trouble COM3 Restore UPS AC Fail UPS AC Restore UPS Battery Low UPS Battery Restore
15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38.
D6500 Output††
SIA †† Output
X X X X X X X X X X X X X
0 1 2 9 10 11 12 13 14 15 16 17 18
[NYZ] [NYX] [NJT] [NYM] [NYR] [NYT] [NYR] [NAT] [NAR] [NVI] [NVO] [NLB] [NLS]
Acknowledge OPERATOR KEYPAD OPERATION SERVICE REQUIRED TIME SET BATTERY MISSING BATTERY PRESENT BATTERY BAD BATTERY RESTORE AC FAIL AC RESTORE PAPER IN PAPER OUT LOCAL PARM PROGRAM IN LOCAL PARM PROGRAM SUCCESSFUL
X 41 X 42
[NLB] [NLS]
LOCAL SOFTWARE PROGRAM IN LOCAL SOFTWARE PROGRAM SUCCESS
X X X X
43 44 45 46
[NLU] [NLD] [NRB] [NRS]
LOCAL PROGRAM FAILURE LOCAL PROGRAM DENIED REMOTE PARM PROGRAM IN REMOTE PARM PROGRAM OK
X 47 X 48
[NRB] [NRS]
REMOTE SOFTWARE PROGRAM IN REMOTE SOFTWARE PROGRAM SUCCESS
X 49 X 50 X 19 X 20 X 21 X 22 X 21 X 22 bbb B X 30 X 31 X 32 X 33 X 34 X 35 X 36
[NRU] [NRD] [NVY] [NVZ] [NVT] [NVR] [NVT] [NVR] [NYBbbb] [NYC] [NYS] [NYK] [NUA01] [NUR01] [NUA02] [NUR02]
REMOTE PROGRAM FAILURE REMOTE PROGRAM DENIED PRINTER ON LINE PRINTER OFF LINE EXTERNAL PRINTER ERROR EXTERNAL PRINTER RESTORE INTERNAL PRINTER ERROR INTERNAL PRINTER RESTORE BUSY SECONDS bbb% COMPUTER ERROR COMPUTER TROUBLE COMPUTER RESTORE UPS AC FAIL UPS AC RESTORE UPS BATTERY LOW UPS BATTERY RESTORE
†
Internal message is not currently implemented.
††
Output messages are abbreviated for clarity
58
Printer Output
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix B: Internal Messages . Table 87:
Internal Messages (continued)
#
Internal Messages
D6500 Output††
SIA Output††
Printer Output
39. 40. 41. 42. 43. 44. 45.
System Reset † System Default System Temperature High System Temperature Restore Slotx/Linex (Lxx) Line Fault Slotx/Linex (Lxx) Line Restore Slotx/Linex (Lxx) Line Card Trouble Slotx/Linex (Lxx) Line Card Restore Slotx/Linex (Lxx) Audio In Slotx/Linex (Lxx) Audio Done Slotx/Linex (Lxx) † Communication Error Slotx/Linex (Lxx) † Communication Restr Slotx/Linex (Lxx) Data Error Slotx/Linex (Lxx) No Data Received Slotx/Linex (Lxx) Reset † Slotx/Linex (Lxx) Codec Error Slotx/Linex (Lxx) Private Call Slotx/Linex (Lxx) No Call Number Slotx/Linex (Lxx) Caller Unknown Set Date Stop Two Way Audio † CPU Data Error † Network Error † Network Restore Account Status Failure Account Status Restore Supervision Rate Changed Switch To Intercept Mode Switch to Fallback Mode Diable Intercept Mode Activate Output Deactivate Output C900 Reboot C900 Battery Low C900 Battery Restore C900 Switched to Intercept C900 Switched to Fallback C900 Output Activated
X X X X X X X
[NYW01] [NYG] [NKA] [NKR] [NLT] [NLR] [NYD]
SYSTEM RESET SYSTEM DEFAULT SYSTEM TEMPERATURE HIGH SYSTEM TEMPERATURE RESTORE PHONE LINE FAULT PHONE LINE RESTORE LINE CARD TROUBLE
X 8
[NYE]
LINE CARD RESTORE
* L X 60
[NLF] [NLE] [NUA03]
AUDIO IN AUDIO DONE COMMUNICATION ERROR
X 61
[NUR03]
COMMUNICATION RESTR
X 62 X 63
[NYN] [NUT04]
DATA ERROR NO DATA RECEIVED
X 64 X 65 P N
[NYW02] [NUT05] [NUT06] [NUT07]
RESET CODEC ERROR PRIVATE CALL NO CALL NUMBER
U
[NUT08]
CALLER UNKNOWN
X 51 X 52 X 53 X 54 X 55 T B02 N B02 X 66 X 88 X 81 X 83 X 84 X 86 X 59 X 58 X 68 X 87 X 82 X 85
[NJD] [CLK] [NYN01] [NNT] [NNR] [NYC] [NYK] [NCO0001] [NCO0002] [NCO0003] [NCO0004] [NCO0005] [NCO0006] [NSC0001] [NSC0002] [NSC0003] [NSC0004] [NSC0005] [NSC0006]
DATE SET TWO WAY AUDIO STOP CPU DATA ERROR NETWORK TROUBLE NETWORK RESTORE COMMUNICATIONS FAILURE COMMUNICATIONS RESTORED SUPERVISION RATE CHANGED SWITCH TO INTERCEPT MODE SWITCH TO FALLBACK MODE DISABLE INTERCEPT MODE ACTIVATE OUTPUT DEACTIVATE OUTPUT C900 REBOOT C900 BATTERY LOW C900 BATTERY RESTORE C900 SWITCHED TO INTERCEPT C900 SWITCHED TO FALLBACK C900 OUTPUT ACTIVATED
46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76.
37 38 39 40 5 6 7
†
Internal message is not currently implemented.
††
Output messages are abbreviated for clarity
Bosch Security Systems | 1/05 | 4998122703D
59
D6600 | Computer Interface Manual | Appendix B: Internal Messages
Table 87:
Internal Messages (continued)
#
Internal Messages
D6500 Output††
SIA Output††
Printer Output
77. 78. 79. 80. 81. 82. 83.
C900 Output Deactivated C900 Input Shorted C900 Input Open C900 Input Restored C900 Intercept Enabled C900 Intercept Disabled No Acknowledgement Received Not Dialing Dialing Error No Response to Handshake No Response to Acknowledgement Message Unknown Invalid Message 30 Minutes Since Fallback Command
X X X X X X X
94 89 90 91 92 93 71
[NSC0007] [NSC0008] [NSC0009] [NSC0010] [NSC0011] [NSC0012] [NYU0001]
C900 OUTPUT DEACTIVATED C900 INPUT SHORTED C900 INPUT OPEN C900 INPUT RESTORED C900 INTERCEPT ENABLED C900 INTERCEPT DISABLED NO ACKNOWLEDGEMENT RECEIVED
X X X X
72 73 74 75
[NYU0002] [NYU0003] [NYU0004] [NYU0005]
NOT DIALING DIALING ERROR NO RESPONSE TO HANDSHAKE NO RESPONSE TO ACK
X 76 X 77 X 95
[NYU0006] [NYU0007] [NMI0001]
MESSAGE UNKNOWN INVALID MESSAGE 30 MIN SINCE FALLBACK CMD
84. 85. 86. 87. 88. 89. 90. †
Internal message is not currently implemented.
††
Output messages are abbreviated for clarity
60
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages .
Appendix C: Radionics Modem IIIa2 Messages For lines that are grouped, Gxx appears instead of Lxx
Table 88:
1.
2.
3.
4.
Radionics Modem IIIa2 Messages
Event
Device/Mode
Display
Abort (User not identified)
Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a h1rrlssssssaaaasIsD41t [#aaaa|NriaAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasIsiiit [#aaaa|Nria/idiiiAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasIiiiit [#aaaa|Nriaa/idiiiiAB] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|Nria/idiiiDGppp] or [#aaaa|Nria/idiii/ssxDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|Nria/idiiiiDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|Nriaa/idiiiDGpppp] or [#aaaa|Nriaa/idiii/ssxDGpppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa AC FAILURE +++ACC aaaa AREA=aa h1rrlssssssaaaasPsssst [#aaaa|NriaaAT] dd/dd tt:tt Lxx ACC aaaa AC FAILURE h1rrlssssssaaaasPsssst [#aaaa|NAT]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt [#aaaa|NATO]
Abort (users < 255)
Abort (users > 254)
Access Granted
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
5.
6.
7.
8.
Access Granted (point < 255, user > 254) Access Granted (point > 254, user < 255) Access Granted (point > 254, user > 255) AC Fail (Area reported)
9.
AC Fail
10.
AC Fail
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
Bosch Security Systems | 1/05 | 4998122703D
Explanation
TROUBLE
ZN z
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
No AC power. Control panel is running on battery power only. You can program the control panel to defer this report. 2, z=0
61
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
11.
AC Fail (as a rider)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasPsssst [#aaaa|NAT]
12.
AC Fail Since Last Call
Printer: D6500 Mode: SIA Mode:
+++ ACC aaaa h1rrlssssssaaaaSPsssst [#aaaa|OAT]
13.
AC Restoral (Area reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa AC RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss0t [#aaaa|NriaaAR] dd/dd tt:tt Lxx ACC aaaa AC RESTORAL h1rrlssssssaaaasRsss0t [#aaaa|NAR] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN z h1rrlssssssaaaasRssszt [#aaaa|NURO] dd/dd tt:tt AC RESTORED RCVR rr h1rrssssssssssssXss14t [NAR] dd/dd tt:tt AC TROUBLED RCVR rr h1rrssssssssssssXss13t [NAT] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT h1rrlssssssaaaasAsssst [#aaaa|NBA]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAssszzt [#aaaa|NBAz] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAszyyt [#aaaa|NBAzyy] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAssxxt [#aaaa|NBAxx] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAss16t [#aaaa|NBA16]
Printer:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaBApppp]
14.
AC Restoral
15.
AC Restoral
16.
AC Restored
17.
AC Troubled
18.
Alarm
19.
Alarm
20.
Alarm
21.
Alarm
22.
Alarm
23.
Alarm (points > 254)
D6500 Mode: SIA Mode:
62
AC FAILED
AC FAILURE
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
No AC power. Control anel is running on battery power only. This report is sent along with the next report transmitted - it is not transmitted independently.
2, D9112
No AC power. Control panel is running on battery power only. You can program the control panel to defer this report.
5.
AC power restored.
D7112
2, z=0
Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report.
ALARM ZN z
1,10
2,9
ALARM ZN zyy
ALARM ZN zxx
ALARM ZN 16
Alarm condition on the zone number shown.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
24.
25.
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Alarm (with Ground Fault) (points > 254)
Printer:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaBApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa POINT=ppp +++ ACC aaaa ID=iii POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NBAppp]
Alarm (Area Not Reported)
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: 26.
27.
28.
29.
30.
31.
32.
Alarm (points < 255)
Alarm with Recent Closing Created due to alarm within 2 min of close (points < 255)
Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Alarm with Recent Closing Created due to alarm within 2 min of close (points > 254, user < 255) Alarm with Recent Closing Created due to alarm within 2 min of close (points > 254, user > 254)
Printer:
Alarm with Recent Closing Created due to alarm within 5 min of close (with Ground Fault) (points > 254, user < 255) Alarm with Recent Closing Created due to alarm within 5 min of close (with Ground Fault) (points > 254, user > 254) Alarm Cross Point (points < 255)
Printer:
D6500 Mode: SIA Mode:
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Printer:
D6500 Mode: SIA Mode:
Printer:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report.
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NriaBAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|Nria/idiiiCRppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiCRpppp]
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiCRpppp]
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAsppppt [#aaaa|Nriaa/idiiiiCRpppp]
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NriaBMppp]
Bosch Security Systems | 1/05 | 4998122703D
63
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
33.
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Alarm Cross Point
Printer:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa CROSS POINT +++ ACC aaaa POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaBMpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT, GROUND FAULT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaBMpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa EXIT ERROR h1rrlssssssaaaasAspppt [#aaaa|NidiiiEAppp]
Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report.
(Area Not Reported) 34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
64
Alarm Cross Point (points > 254)
Alarm Cross Point (with Ground Fault) (points > 254) Alarm Door Forced (points > 254)
Alarm Exit Error (Area Not Reported)
Alarm Exit Error (points < 255)
Alarm Exit Error (points > 254, user < 255)) Alarm Exit Error (points > 254, user > 254) Alarm Exit Error (with Ground Fault) (points > 254, user < 255)
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report.
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|Nria/idiiiEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiEApppp]
Alarm Exit Error (with Ground Fault) (points > 254, user > 254)
Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|Nriaa/idiiiiEApppp]
Alarm Fire
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasFssszt [#aaaa|NFAz]
FIRE FR z
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
44.
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Alarm Silenced
Printer:
dd/dd tt:tt Lxx ACC aaaa ALARM SILENCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaFSppppt [#aaaa|NriaaFLpppp] dd/dd tt:tt Lxx ACC aaaa ALL PTS TESTED h1rrlssssssaaaasRsssFt [#aaaa|NTC] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaANppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaANppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRsppppt [#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRsppppt [#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaASppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTsppppt [#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTsppppt [#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaasTsppppt [#aaaa|Nriaa/lvlll/vavvvASpppp] dd/dd tt:tt Lxx ACC aaaa AREA WATCH +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD51t [#aaaa|Nria/idiiiTW] dd/dd tt:tt Lxx ACC aaaa WATCH MODE END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD52t [#aaaa|Nriaa/idiiiiTZ] dd/dd tt:tt Lxx ACC aaaa WATCH START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD51t [#aaaa|Nriaa/idiiiiTW]
45.
All Points Tested
46.
Analog Restoral (points < 255)
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
Analog Restoral (points < 255)
Analog Restoral (points > 254) Analog Restoral (points > 254)
Analog Service (points < 255)
Analog Service (points > 254)
Analog Service (points > 254)
Analog Service (points > 254) (Level and Value Reported) Area Watch
Area Watch (Watch mode ended) (users > 254) Area Watch (Watch mode started) (users > 254)
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Bosch Security Systems | 1/05 | 4998122703D
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
65
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
57.
Audio Done
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx AUDIO DONE h1rrlsssssssssssLsssst [NLE]
58.
Audio In
59.
Battery Low
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx AUDIO IN h1rrlsssssssssss*sssst [NLF] dd/dd tt:tt Lxx ACC aaaa BATTERY LOW h1rrlssssssaaaasTsss9t [#aaaa|NYT]
60.
Battery Low
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBT9] dd/dd tt:tt Lxx ACC aaaa BATTERY LOW +++ACC aaaa AREA=aa h1rrlssssssaaaasTsss9t [#aaaa|NriaaYT] +++ ACC aaaa BATTERY LOW h1rrlssssssaaaaSTsssst [#aaaa|OYT]
61.
Battery Low (Area reported)
Explanation
63.
Battery Low Since Last Call
64.
Battery Missing Since Last Call
Printer: D6500 Mode: SIA Mode:
+++ ACC aaaa h1rrlssssssaaaaSTsssst [#aaaa|OYM]
65.
Battery Restoral (Area reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss9t [#aaaa|NriaaYR] dd/dd tt:tt Lxx ACC aaaa BATTERY MISSING h1rrlssssssaaaasTsss9t [#aaaa|NYM]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBT9] dd/dd tt:tt BATTERY MISSING RCVR rr h1rrssssssssssssXsss9t [NYM] dd/dd tt:tt BATTERY PRESENT RCVR rr h1rrssssssssssssXss10t [NYR] dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE h1rrlssssssaaaasRsss9t [#aaaa|NYR]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRssszt [#aaaa|NUR9]
66.
Battery Missing
67.
Battery Missing
68.
Battery Missing
69.
Battery Present
70.
Battery Restoral
71.
Battery Restoral
66
BATTERY MISSING
RESTORAL ZN z
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The control panel battery discharged to 11.8 VDC or less. 2, z=9
The control panel battery discharged to 11.8 VDC or less.
5.
The control panel battery is connected incorrectly, disconnected, or completely discharged.
5.
The control panel battery is connected incorrectly, disconnected, or completely discharged. 2, z=9
The control panel battery charged to 13.2 VDC after a BATTERY LOW was reported (the battery is fully charged at 13.8 VDC). 2, z=9
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
72.
Battery Restoral
73.
Blank Line
dd/dd tt:tt BATTERY RESTORED RCVR rr h1rrssssssssssssXss12t [NYR] print blank line (CR and LF)
74.
Busy Seconds
75.
Bypass, Command
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
76.
Bypass, Programmer
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
77.
78.
79.
80.
81.
82.
Bypass, Remote (Call back)
Printer:
Bypass, Remote (No Call back)
Printer:
Bypass Restore
Printer:
Bypass Restore (points < 255)
Bypass Restore (point < 255) (Fire point)
Bypass Restore (points < 255) (Supervisory point)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx BUSY SECONDS bbb% RCVR rr h1rrlsssssssbbbsBsssst [NYBbbb] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|Nria/idiiiUBppp] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt [#aaaa|Nria/pidddUBppp]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA in the second line of the report is faulted, and was bypassed by a programmer with the specified serial device number when the system was armed.
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp PH#=h h1rrlssssssaaaasNspppt [#aaaa|Nria/phhUBppp]
The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through the specified phone line.
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaUBppp]
The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through the specified phone line.
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa POINT=ppp h1rrlssssssaaaaRBspppt [#aaaa|NUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt [#aaaa|NriaUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt [#aaaa|NriaFUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt [#aaaa|NriaSUppp]
Bosch Security Systems | 1/05 | 4998122703D
67
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
83.
84.
85.
86.
87.
88.
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Bypass Restore (points < 255) (Waterflow point))
Printer:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt [#aaaa|NriaWUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt [#aaaa|NriaaUUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa FIRE POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt [#aaaa|NriaaFUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt [#aaaa|NriaaSUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt [#aaaa|NriaaWUpppp]
Bypass Restore (point > 254)
Bypass Restore (point > 254) (Fire point)
Bypass Restore (point > 254) (Supervisory point) Bypass Restore (point > 254) (Waterflow point)
Bypass, Sked
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ ACC aaaa AREA=a POINT=ppp SKED=kk h1rrlssssssaaaasNspppt [#aaaa|Nria/aikkUBppp]
The POINT in the AREA in the second line of the report is faulted, and was bypassed when the system was armed by the specified Sked.
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaUBppp]
The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point restores while the system is armed, it returns to the system, and is ready to detect faults. A system in alarm was disarmed before the bell time expired. The specified point sends a Cancel Report for the alarmed area.
D6500 Mode: SIA Mode:
89.
Bypass, Swinger
Explanation
Printer:
90.
Cancel
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas\sssst [#aaaa|NOC]
CANCEL REPORT
91.
Cancel
Cancel
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas\sssit [#aaaa|NOCi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas\siyyt [#aaaa|NOCiyy]
CANCEL ID i
92.
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
68
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
CANCEL ID iyy
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
93.
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Cancel Alarm
Printer:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\sssst [#aaaa|Nria/idiiiBC]
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
1.
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaas\sssst [#aaaa|NidiiiBC]
CANCEL ALARM ID=iii
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit [#aaaa|Nria/idiiiBC]
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
D6500 Mode: SIA Mode: 94.
95.
Cancel Alarm (Area Not Reported)
Printer:
Cancel Alarm (Non-Fire)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: 96.
97.
Cancel Alarm (Non-Fire)
Cancel Alarm (Non-Fire) (users > 254)
98.
Cancel Alarm by Area
99.
Cancel, Fire Alarm
100. Card Assigned (By Programmer)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: 101. Card Assigned (By Programmer) (users > 254) 102. Card Assigned (By Remote)
Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: 103. Card Assigned (By Remote) (users > 254)
Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=a h1rrlssssssaaaas\sssst [#aaaa|NriaBC] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit [#aaaa|Nriaa/idiiiiBC] dd/dd tt:tt Lxx ACC aaa CANCEL REPORT h1rrlssssssaaaas\sssst [#aaaa|NOC]
A system in alarm was disarmed before the bell time expired. The specified point sends a Cancel Report for the alarmed area.
2, 9
dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit [#aaaa|Nria/idiiiFC] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa CRD=iii-x SDI=ddd h1rrlssssssaaaasNsD30t [#aaaa|NpidddDAiii] or [#aaaa|Npiddd/ssxDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD30t [#aaaa|Npiddd/DAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY REMOTE +++ ACC aaaa CRD=iii-x h1rrlssssssaaaasNsD30t [#aaaa|NDAiii] or [#aaaa|NssxDAiii] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD30t [#aaaa|NDAiiii]
Bosch Security Systems | 1/05 | 4998122703D
CARD ASSIGNED BY REMOTE CRD=iiii
69
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
104. Card Assigned (By User)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY USER +++ ACC aaaa CRD=iii-x ID=iii h1rrlssssssaaaasNsD30t [#aaaa|NidiiiDAiii] or [#aaaa|Nidiii/ssxDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER h1rrlssssssaaaasNsD30t [#aaaa|NDA] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD30t [#aaaa|NidiiiiDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER h1rrlssssssaaaasNsD31t [#aaaa|NDB] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD31t [#aaaa|NidiiiiDBiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD31t [#aaaa|NpidddDBiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iiii h1rrlssssssaaaasNsD31t [#aaaa|NDBiiii] dd/dd tt:tt Lxx CARD RESTORED RCVR rr h1rrlsssssssssssXsss8t [NYE] dd/dd tt:tt Lxx CARD TROUBLED RCVR rr h1rrlsssssssssssXsss7t [NYD] dd/dd tt:tt Nll ACC aaaa STATUS CHANGED +++ aaaa C900 BATTERY LOW h1rrlssssssaaaasXss58t [#aaaa|NSC0002] dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL h1rrlssssssaaaasAsD12t [#aaaa|NYX]
D6500 Mode: SIA Mode: 105. Card Assigned (By User, User not identified) 106. Card Assigned (By User) (users > 254)
107. Card Deleted (By User, User not identified) 108. Card Deleted (By User) (users > 254)
109. Card Deleted (By Programmer) (users > 254) 110. Card Deleted (By Remote) (users > 254)
111. Card Restored
112. Card Troubled
113. Change Of Status (C900 Battery Low) 114. Checksum Fail
115. Checksum Fail (SDI Device and Point reported)
70
Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasAspppt [#aaaa|NpidddYXppp]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The program in the control panel is corrupt. Send service immediately. The program in the control panel is corrupt. Send service immediately.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
116. Closing
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCL]
CLOSING REPORT
117. Closing
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
CLOSING ZN i
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssit [#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssit [#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsiyyt [#aaaa|NCLiyy] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCL]
121. Closing by Account (area not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit [#aaaa|NCLi]
122. Closing by Account
Printer:
CLOSING REPORT ID=iii
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCL]
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
123. Closing by Account (ID not reported) (area not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCL]
CLOSING REPORT
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
1,
124. Closing by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst [#aaaa|NCL]
CLOSING REPORT
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
2,
125. Closing by Area
Printer:
dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCL]
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
1.
118. Closing
119. Closing
120. Closing by Account
D6500 Mode: SIA Mode: 126. Closing by Area 127. Closing by Area
128. Closing by Area (users > 254)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
CLOSING ID i
CLOSING ID iyy
CLOSING REPORT ID=iii
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
CLOSING ZN i
2, i = user id.
dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaasCssszt [#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCL]
Bosch Security Systems | 1/05 | 4998122703D
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
D7112
D7112
2, z = area number
71
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
129. Closing by Area (ID not reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NriaCL]
CLOSING REPORT AREA=a
130. Closing Early By Account
Printer:
CLOSING EARLY ID=iii
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCK]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit [#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCK]
CLOSING ZN i
133. Closing Early by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst [#aaaa|NCL]
134. Closing Early By Area
Printer:
dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCK]
131. Closing Early by Account 132. Closing Early By Account (ID not reported)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
135. Closing Early By Area
136. Closing Early by Area 137. Closing Early By Area (ID not reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
138. Closing Early By Area (users > 254) 139. Closing Late by Account (area not reported)
72
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NriaCK] dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCssszt [#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NriaCK]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
1,
A user with the ID in the second line of the report armed the AREA before the programmed closing time window.
1,
D7112
D7112
2, i = user id.
CLOSING EARLY
CLOSING REPORT
A user with the ID in the second line of the report armed the AREA before the programmed closing time window.
1,
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
2,
A user with the ID in the second line of the report has armed the AREA before the programmed closing time window.
1.
D7112
D7112
CLOSING EARLY AREA=a
CLOSING ZN z
2, z = area number
CLOSING EARLY AREA=a
dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCK] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCJ]
A user with the ID in the second line of the report armed the AREA before the programmed closing time window.
1,
A user with the ID in the second line of the report armed the AREA after the programmed closing time window.
1,
D7112
D7112
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit [#aaaa|NCLi]
CLOSING ZN i
141. Closing Late by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCJ]
CLOSING LATE
142. Closing Late by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst [#aaaa|NCL]
143. Closing Late by Area
Printer:
dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCJ]
140. Closing Late by Account
D6500 Mode: SIA Mode:
144. Closing Late by Area 145. Closing Late by Area
146. Closing Late by Area (users > 254) 147. Closing Late by Area (ID not reported)
148. Command Bypass
149. Command Bypass
150. Command Bypass (point < 255, user > 254) 151. Command Bypass (point > 254, user < 255)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140 2, i = user id
CLOSING REPORT
dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaasCssszt [#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaCJ] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCJ] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaCJ]
dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasNspppt [#aaaa|Nria/idiiiUBppp] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz]
A user with the ID in the second line of the report armed the AREA after the programmed closing time window.
1,
The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID.
2,
A user with the ID in the second line of the report armed the AREA after the programmed closing time window.
1.
D7112
D7112
2, z = area number
A user with the ID in the second line of the report armed the AREA after the programmed closing time window.
1, D7112
1.
9, D9112
dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|Nria/idiiiiUBppp] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|Nriaa/idiiiUBpppp]
Bosch Security Systems | 1/05 | 4998122703D
73
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
152. Comm Fail
153. Comm Fail (SDI Device not reported)
154. Comm Restoral
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsB01t [#aaaa|NphhYC] dd/dd tt:tt Lxx ACC aaaa
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
155. Comm Restoral (SDI Device not reported)
Printer:
156. Communicatio ns Fail (2212/9112)
Printer:
158. Communicatio ns Trouble (Route Group and SDI Device# reported) 159. Communicatio ns Trouble Restoral
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
COMM FAIL
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsB01t [#aaaa|NrggYK]
RG=g
COMM RESTORAL PHONE#=h
The PHONE# specified in the second line of the report was restored.
COMM RESTORAL RG=g
The PHONE# specified in the second line of the report was restored.
dd/dd tt:tt Lxx ACC aaaa COMM FAIL +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t [#aaaa|NphhhYC] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t [#aaaa|NphhhYS] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasTsB01t [#aaaa|Nrgg/pidddYS]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa PH#=hh h1rrlssssssaaaasNsB01t [#aaaa|NphhhYK] dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasNsB01t [#aaaa|Nrgg/pidddYK]
161. Computer Error
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx COMPUTER ERROR h1rr0sssssssssssXss30t [NYC]
Indicates a complete loss of communication between receiver and automation system.
162. Computer Restore
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx COMPUTER RESTORE h1rr0sssssssssssXss32t [NYK]
Indicates that communication between the receiver and the automation system was restored.
163. Computer Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx COMPUTER TROUBLE h1rr0sssssssssssXss31t [NYS]
Indicates that an automation message was rejected by the automation software.
160. Communicatio ns Trouble Restoral (Route Group and SDI Device# reported)
74
Printer:
h1rrlssssssaaaasTsB01t [#aaaa|NrggYC] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsB01t [#aaaa|NphhYK]
D6500 Mode: SIA Mode: Printer:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
COMM FAIL PHONE#=h
+++ ACC aaaa
D6500 Mode: SIA Mode:
157. Communicatio ns Trouble
Explanation
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
164. Create Status Report
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
165. Custom Function (Custom Function Initiated)
Printer:
dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY CUSTOM FUNCTION +++ACC aaaa CUST.FX=fff AREA=aa ICF=fff h1rrlssssssaaaasNsD39t [#aaaa|Nriaa/cffffCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY SKED +++ACC aaaa CUST.FX=fff AREA=aa SKED=kkk h1rrlssssssaaaasNsD39t [#aaaa|Nriaa/aikkkCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iii h1rrlssssssaaaasNsD39t [#aaaa|Nriaa/idiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iiii h1rrlssssssaaaasNsD39t [#aaaa|Nriaa/idiiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa h1rrlssssssaaaasNsD39t [#aaaa|NriaaCXfff] dd/dd tt:tt Lxx ACC aaaa DATE CHANGED +++ ACC aaaa ID= iii h1rrlssssssaaaasNsD07t [#aaaa|NidiiiJD]
166. Custom Function (Sked Initiated) 167. Custom Function (users < 255) (User Initiated) 168. Custom Function (users > 254) User Initiated) 169. Custom Function (User Initiated, User not identified) 170. Date Changed
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
171. Date Changed
Printer: D6500 Mode: SIA Mode:
172. Date Changed
173. Date Changed (users > 254)
174. Diagnostic
175. Diagnostic
Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD07t [#aaaa|NidiiiJD]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD07t [#aaaa|NJD] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD07t [#aaaa|NidiiiiJD] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasYsssst [#aaaa|NYX]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasYssszt [#aaaa|NYXz]
Bosch Security Systems | 1/05 | 4998122703D
Explanation
STATUS REPORT
DATE CHANGED ID=iii
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Indicates that the next report is an Account Status Report.
The user changed the control panel date or time with the ID specified in the second line of the report.
D9112
The user changed the control panel date or time with the ID specified in the second line of the report.
DATE CHANGED
DATE CHANGED ID=iiii
DIAG REPORT
A Command 42 was entered at a keypad to send a diagnostic report. No service conditions in trouble memory to report.
DIAG ZN z
75
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
176. Door Closed, Restoral
177. Door Cycled
178. Door Cycled (By User)
179. Door Cycled (By Programmer) (points > 254) 180. Door Cycled (By Remote) (points > 254)
181. Door Cycled (By User) (points < 255, users > 254) 182. Door Cycled (By User) (points > 254, users < 255) 183. Door Cycled (By User) (points > 254, users > 254) 184. Door Cycled (By User, User not identified) (points < 255) 185. Door Cycled (By User, User not identified) (points > 254) 186. Door Cycled (points > 254)
187. Door Left Open
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa REST-DR CLOSED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaDHppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|Nria/idiiiDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAGppppt [#aaaa|Nriaa/pidddDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|Nria/idiiiiDGppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
76
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The Modifier “/ssx” refers to the Data Type Address, not the Modifiers “idiii,” or “piddd”
dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|Nriaa/idiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAGpppptv [#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAOspppt [#aaaa|NriaDNppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
188. Door Left Open (points > 254) 189. Door Left Open (Point text reported)
190. Door Left Open, Alarm
191. Door Left Open, Alarm (points > 254) 192. Door Left Open, Alarm (Text reported)
193. Door Left Open, Alarm (Point text and User Name reported) 194. Door Left Open, Trouble
195. Door Left Open, Trouble (Text reported)
196. Door Left Open, Trouble (Point text and User name reported) 197. Door Locked
198. Door Locked (Automatic)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa DOOR LEFT OPEN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAOppppt [#aaaa|NriaaDNpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (ptext) h1rrlssssssaaaaAOspppt [#aaaa|NriaDNppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaDLpppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) h1rrlssssssaaaasAspppt [#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (ptext) +++ ACC aaaa (uname) h1rrlssssssaaaasAspppt [#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) h1rrlssssssaaaasTspppt [#aaaa|NriaDMppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) +++ ACC aaaa (uname) h1rrlssssssaaaasTspppt [#aaaa|NriaDMppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt [#aaaa|NriaDYLpp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt [#aaaa|NriaDYppp]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Bosch Security Systems | 1/05 | 4998122703D
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
77
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
199. Door Locked (Automatic) (points > 254)
200. Door Locked (By Programmer) (points > 254) 201. Door Locked (By Remote) (points > 254)
202. Door Locked (By Sked) (points > 254)
203. Door Locked (By User)
204. Door Locked (By User) (points > 254, users < 255) 205. Door Locked (By User) (points > 254, users > 254) 206. Door Locked (By User, User not identified) (points < 255) 207. Door Locked (By User, User not identified) (points > 254) 208. Door Locked (points > 254)
209. Door Request (Request to Enter) (points > 254) 210. Door Request (Request to Exit) (points > 254)
78
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaALppppt [#aaaa|Nriaa/pidddDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaALppppt [#aaaa|Nriaa/aikkkDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaALspppt [#aaaa|Nria/idiiiDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|Nriaa/idiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|Nriaa/idiiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt [#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt [#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|NriaaDEpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt [#aaaa|NriaaDXpppp]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
211. Door Request (REX)
212. Door Request (REX, Denied) (Interlock Deny) 213. Door Request (REX, Denied) (Door Secured) 214. Door Request (RTE)
215. Door Request (RTE, Denied) (Door Secured) (points > 254) 216. Door Request (RTE, Denied) (Interlock Deny) (points > 254) 217. Door Request (RTX, Denied) (Door Secured) (points > 254) 218. Door Request (RTX, Denied) (Interlock Deny) (points > 254) 219. Door Secured
220. Door Secured (Automatic)
221. Door Secured (Automatic) (points > 254)
222. Door Secured (By Programmer) (points > 254)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|NriaDXppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa DENIED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa DENIED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|NriaDKppp]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt [#aaaa|NriaDEppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt [#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt [#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaASppppt [#aaaa|Nriaa/pidddDCpppp]
Bosch Security Systems | 1/05 | 4998122703D
79
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
223. Door Secured (By Remote) (points > 254)
224. Door Secured (By Sked) (points > 254)
225. Door Secured (By User)
226. Door Secured (By User) (points 254) 227. Door Secured (By User) (points > 254, users < 255) 228. Door Secured (By User) (points > 254, users > 254) 229. Door Secured (By User, User not identified) (points < 255) 230. Door Secured (By User, User not identified) (points > 254) 231. Door Secured (points > 254)
232. Door Unlocked
233. Door Unlocked (Automatic)
234. Door Unlocked (By User)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaASppppt [#aaaa|Nriaa/aikkkDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID-iii POINT=ppp h1rrlssssssaaaaASspppt [#aaaa|Nria/idiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaASspppt [#aaaa|Nria/idiiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|Nriaa/idiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|Nriaa/idiiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt [#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt [#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt [#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt [#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAUspppt [#aaaa|Nria/idiiiDOppp]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
80
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
235. Door Unlocked (Automatic) (points > 254) 236. Door Unlocked (By Programmer) (points > 254) 237. Door Unlocked (By Remote) (points > 254) 238. Door Unlocked (By Sked) (points > 254) 239. Door Unlocked (By User) (points < 255, users > 254) 240. Door Unlocked (By User) (points > 254, users < 255) 241. Door Unlocked (By User) (points >254, users > 254) 242. Door Unlocked (By User, User not identified) (points > 254) 243. Door Unlocked (By User) (points > 254) 244. Duress
245. Duress
Device/Mode
Display
Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAUppppt [#aaaa|Nriaa/pidddDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaAUppppt [#aaaa|Nriaa/aikkkDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAUspppt [#aaaa|Nria/idiiiiDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|Nriaa/idiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|Nriaa/idiiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt [#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DURESS +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasDsiiit [#aaaa|Nria/idiiiHA]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt [#aaaa|NBAz]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
ALARM ZN z
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report.
1.
2, D7112: z=0. D9112: z= as programmed in BFSK Duress Code
Bosch Security Systems | 1/05 | 4998122703D
81
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
246. Duress
247. Duress (Area Not Reported)
248. Duress
Device/Mode
Display
Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasDssszt [#aaaa|NHAz]
DURESS ID z
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasDsiiit [#aaaa|NidiiiHA]
DURESS ID=iii
A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report.
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasDsiiit [#aaaa|Nria/idiiiHA]
DURESS ID=iii
A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report.
D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode:
249. Duress (user > 254)
250. Early Open By Account
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa DURESS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasDiiiit [#aaaa|Nriaa/idiiiiHA] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit [#aaaa|NidiiiOK]
EARLY TO OPEN ID=iii
251. Early Open By Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NOK]
EARLY TO OPEN
252. Early Open By Account
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssit [#aaaa|NOPi]
OPENING Zn I
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NOP]
OPENING REPORT
253. Early Open By Account (ID not reported) 254. Early Open By Area (ID not reported)
Printer:
255. Early Open By Area
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
256. Early Open By Area
82
Printer: D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NriaOK]
1,
A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window.
1,
D7112
D7112
2, 9.
EARLY TO OPEN AREA=a
dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOK]
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOssszt [#aaaa|NOPz]
A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window.
OPENING ZN z
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
2,
A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window.
1,
A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window.
1.
9. D7112
D7112
2, z = area number
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
257. Early To Close (7112 Only) 258. Early To Open (7112 Only) 259. Equipment Fail (Report from UPLINK router indicating ”Transceiver Trouble Condition”) 260. Error
261. Error
262. Error
263. Error
264. Extend Close Time by Area
265. Extend Close Time by Area
266. Extend Close Time by Area (ID not reported) 267. Extend Close Time by Area (users < 255) 268. Extend Close Time by Area (users > 254) 269. Extra Point
Device/Mode
Display
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCK] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NOK]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
A user with the ID in the second line of the report extended the closing time of the AREA to the TIME printed.
1.
A user with the ID in the second line of the report extended the closing time of the AREA to the TIME printed.
1,
CLOSING EARLY
EARLY TO OPEN
EQUIPMENT FAIL
+++ ACC aaaa
SDI=255 COND=001
+++ ACC aaaa
UPLINK.
h1rrlssssssaaaasTsD29t [#aaaa|Npi255IA001]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN h1rrlssssssaaaas[sssst [#aaaa|NRT] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN z h1rrlssssssaaaas[ssszt [#aaaa|NRTz] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN zz h1rrlssssssaaaas[sszzt [#aaaa|NRTzz] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN zzz h1rrlssssssaaaas[szzzt [#aaaa|NRTzzz] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ ACC aaaa AREA=a ID=iii TIME=hh:mm h1rrlssssssaaaasTsD26t [#aaaa|Nria/idiii/tihhmmCE]
dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a TIME=hh:mm h1rrlssssssaaaasTsD26t [#aaaa|Nria/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ ACC aaaa AREA=a TIME=hh:mm h1rrlssssssaaaasTsD26t [#aaaa|Nria/tihhmmCE]
D7112
dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a ID=iiii TIME=hh:mm h1rrlssssssaaaasTsD26t [#aaaa|Nriaa/idiiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=aa ID=iiii TIME=hh:mm h1rrlssssssaaaasTsD26t [#aaaa|Nriaa/idiiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaXEppp]
Bosch Security Systems | 1/05 | 4998122703D
83
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
270. Extra Point (points > 254)
271. Extra RF Point
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaXEpppp]
D6500 Mode: SIA Mode: Printer:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
An extra RF POINT in the AREA in the second line of the report was detected.
1,
Abnormal RAM session termination or beginning of the Command 58 Fire Test.
2.
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsD16t [#aaaa|NpidddXF] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsD16t [#aaaa|NriaXF]
273. Fail To Call RAM
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssFt [#aaaa|NBTF]
274. Fail To Call RAM
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM h1rrlssssssaaaasTsF02t [#aaaa|NRA]
Control panel attempted to call RAM and was unsuccessful.
275. Fail To Close by Area
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssEt [#aaaa|NriaCI]
The AREA in the second line of the report was not armed before the programmed closing time.
272. Extra RF Point Detected
D6500 Mode: SIA Mode:
276. Fail To Close by Area
Printer: D6500 Mode: SIA Mode:
277. Fail To Close, Delinquent
278. Fail To Execute (Door UnlockedInterlock) 279. Fail to Execute (Door UnlockedInterlock) (points > 254) 280. Fail To Execute (Door UnlockedDoor Secured)
84
Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssEt [#aaaa|NriaCI]
EXTRA RF POINT SDI=ddd
EXTRA RF POINT
TROUBLE ZN F
FAIL TO CLOSE AREA=a
FAIL TO CLOSE AREA=a
D7112
The AREA in the second line of the report was not armed before the programmed closing time.
dd/dd tt:tt Lxx ACC aaaa DELNQNT CLOSING +++ACC aaaa AREA=a h1rrlssssssaaaasTsssEt [#aaaa|NriaCD] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR UNLOCKED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t [#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR UNLOCKED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t [#aaaa|NriaDKppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
281. Fail To Execute (Door UnlockedDoor Secured) (points > 254)
Printer:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-DOOR SECURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t [#aaaa|NriaaDKpppp]
282. Fail To Execute (Door UnlockedDoor Secured) (points > 254)
Printer:
283. Fail To Execute (Door UnlockedDoor Secured) (points < 255)
Printer:
284. Fail To Execute (Door CycledInterlock)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURE +++ACC aaaa AREA=aa POINT=ppp h1rrlssssssaaaasNsD35t [#aaaa|NriaDKppp]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR CYCLED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR CYCLED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa INCORRECT RESPONSE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t [#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa NO RESPONSE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t [#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO OPEN +++ ACC aaaa AREA=a h1rrlssssssaaaasTsssEt [#aaaa|NriaOI]
290. Fail To Call RAM
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM h1rrlssssssaaaasTsF02t [#aaaa|NRA]
Control panel attempted to call RAM and was unsuccessful.
291. Fire Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NriaFAppp]
Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report.
285. Fail To Execute (Door CycledInterlock) (points > 254) 286. Fail To Execute (Door CycledDoor Secured) 287. Fail To Execute (SDI Device, Incorrect Response) 288. Fail To Execute (SDI Device, No Response) 289. Fail To Open by Area
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Bosch Security Systems | 1/05 | 4998122703D
The AREA in the second line of the report was not disarmed during the programmed opening time window.
1, 10.
85
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasFssszt [#aaaa|NFAz]
293. Fire Alarm (Area Not Reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasFspppt [#aaaa|NFAppp]
294. Fire Alarm (point < 255)
Printer:
292. Fire Alarm
Explanation
FIRE FR z
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140 2, 3, 9.
295. Fire Alarm (point < 255)
296. Fire Alarm (point < 255)
297. Fire Alarm (point < 255)
298. Fire Alarm (point < 255)
299. Fire Alarm Cross point (point > 254)
300. Fire Alarm Crossed Point (Area Not Reported)
301. Fire Alarm Smoke (point > 254)
302. Fire Alarm (point > 254)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
86
FIRE ALARM POINT=ppp
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NriaFMppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NriaFAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NriaKAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NriaSAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt [#aaaa|NriaaFApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt [#aaaa|NriaaFMpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ ACC aaaa CROSS POINT +++ ACC aaaa POINT=ppp h1rrlssssssaaaasFspppt [#aaaa|NFMppp]
Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report.
Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report.
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt [#aaaa|NriaaFApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt [#aaaa|NriaaKApppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
303. Fire Alarm (point > 254)
304. Fire Cancel (users > 254)
305. Fire Missing
306. Fire Missing
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa WATER FLOW DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt [#aaaa|NriaaSApppp] dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit [#aaaa|Nriaa/idiiiiFC]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt [#aaaa|NriaFYppp]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaGsssszt [#aaaa|NFTz]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT (programmed with a Fire Point code) in the AREA in the second line of the report is missing.
1,
TROUBL FR z
10.
2, 3, 9.
307. Fire Missing (points > 254)
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|NriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFJppp]
310. Fire Restoral after Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt [#aaaa|NFRz]
311. Fire Restoral after Alarm
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE RESTORAL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFRppp]
The POINT (programmed with a Fire Point code) in the AREA specified in the second line of the report was restored after an alarm, trouble, or missing condition.
1,
dd/dd tt:tt Lxx ACC aaaa FIRE RESTORAL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFRppp]
The POINT (programmed with a Fire Point code) in the AREA specified in the second line of the report was restored after an alarm, trouble, or missing condition.
1,
308. Fire Restoral (from Fire Alarm) 309. Fire Restoral(from Trouble/Missi ng/Supervision )
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
RESTORAL FR z
2, 3, 9.
D6500 Mode: SIA Mode:
312. Fire Restore after Trouble/Missi ng
Printer: D6500 Mode: SIA Mode:
Bosch Security Systems | 1/05 | 4998122703D
10.
10.
87
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
313. Fire Restore after Trouble/Missi ng
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt [#aaaa|NFRz]
314. Fire Restoral From Fire Alarm (no area)
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt [#aaaa|NriaaFHpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TBL RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt [#aaaa|NriaaFJpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt [#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt [#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt [#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt [#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaFWppp]
315. Fire Restoral From Fire Alarm (points > 254) 316. Fire Restoral From Trouble/Missi ng/Supervision 317. Fire Supervision
318. Fire Supervision (points < 255) 319. Fire Supervision (points > 254)
320. Fire Supervision (Water Flow) (points < 255) 321. Fire Supervision (Water Flow) (points > 254) 322. Fire Supervision Restore (points < 255) 323. Fire Supervision Restore (points > 254) 324. Fire Supervision Restore (Water Flow) (points < 255) 325. Fire Supervision Restore (Water Flow) (points > 254)
88
Explanation
RESTORALFR z
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140 2, 3, 9.
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt [#aaaa|NriaFVppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt [#aaaa|NriaaFVpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt [#aaaa|NriaFVppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt [#aaaa|NriaaFVpppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
326. Fire Supervision Trouble (points < 255) 327. Fire Supervision Trouble (points > 254) 328. Fire Supervision Trouble (Water Flow) (points < 255) 329. Fire Supervision Trouble (Water Flow) (points > 254) 330. Fire Supervision Trouble Restore (points < 255)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaFWppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFWpppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
331. Fire Supervision Trouble Restore (points > 254)
Printer:
332. Fire Supervision Trouble Restore (Water Flow) (points < 255)
Printer:
333. Fire Supervision Trouble Restore (Water Flow) (points > 254)
Printer:
334. Fire Trouble
Printer:
335. Fire Restoral
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Trouble condition from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report.
1,
dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt [#aaaa|NriaFQpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt [#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt [#aaaa|NriaFQpppp]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaFTppp]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt [#aaaa|NFRz]
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaFTppp]
RESTORAL FR z
10.
2, 3, 9.
336. Fire Trouble (point < 255)
D6500 Mode: SIA Mode:
Bosch Security Systems | 1/05 | 4998122703D
89
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
337. Fire Trouble (point < 255)
338. Fire Trouble (point < 255)
339. Fire Trouble (point < 254)
340. Fire Trouble (with Ground Fault) (point > 254) 341. Fire Trouble (point > 254)
342. Fire Trouble (point > 254)
343. Fire Trouble (point > 254)
344. Fire Walk End
345. Fire Walk End
346. Fire Walk Start
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaKTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt [#aaaa|NriaSTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaKTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt [#aaaa|NriaaSTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ ACC aaaa AREA=a h1rrlssssssaaaasRsssFt [#aaaa|NriaFK] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN F h1rrlssssssaaaasRsssFt [#aaaa|NURF] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiFI] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN F h1rrlssssssaaaasTsssFt [#aaaa|NBTF]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
347. Fire Walk Start
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
348. Fire Walk Start
Printer: D6500 Mode: SIA Mode:
90
Explanation
dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiFI]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Fire Walk Test ended.
D9112
Fire Walk Test begun.
D9112
Abnormal RAM session termination or beginning of the Command 58 Fire Test.
D9112
Fire Walk Test begun.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
349. Fire Walk Start (no user)
350. Fire Walk Start (users > 254)
351. Fire Walk End (no users)
352. Fire Walk End (users > 254)
353. Force Armed
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt [#aaaa|NriaFI]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt [#aaaa|Nriaa/idiiiiFI] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NriaFK]
FIRE WALK END AREA=a
dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt [#aaaa|Nriaa/idiiiiFK] dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED h1rrlssssssaaaasWsssst [#aaaa|NCW]
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report.
FORCED CLOSE ID=iii
A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed.
1,
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCF]
355. Force Close by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCF]
FORCED CLOSE
A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed.
1,
356. Force Close by Area
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCF]
A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed.
1.
357. Force Close Early by Account
Printer:
dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst [#aaaa|NCLi] [#aaaa|NCW]
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points which were not armed are indicated by a TROUBLE or SHUNTED report.
2,
354. Force Close by Account
Printer:
D6500 Mode: SIA Mode:
Bosch Security Systems | 1/05 | 4998122703D
CLOSING ZN I WAS FORCE ARMED
D7112
D7112
I = user id.
91
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
358. Force Close Early by Account
Printer:
dd/dd tt:tt Lxx ACC aaaa F CLOSE EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCF]
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed.
1.
359. Force Close Early by Account (ID not reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NriaCF]
F CLOSE EARLY AREA=a
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed.
1,
360. Force Close Early by Account
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCF]
F CLOSE EARLY ID=iii
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed.
1,
361. Force Close Early by Account (ID not reported)
Printer:
The system armed/disarmed with a passcode or COMMAND 1 reporting no User ID (D8112G2 excluded). AREA armed by user with the ID in the second line of the report
2,
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst [#aaaa|NCL] [#aaaa|NCW]
CLOSING REPORT WAS FORCE ARMED
D7112
D7112 by Account
D7112
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 362. Force Close Early by Account (ID not reported)
92
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCF]
F CLOSE EARLY
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed.
1, D7112
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
363. Forced Close Early by Area
Device/Mode
Display
Explanation
Printer:
dd/dd tt:tt Lxx ACC aaaa F CLOSE LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCF]
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA before the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA before the programmed closing time while points in the AREA were faulted. Faulted points were not armed. Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. Unexpanded reporting, system armed by arm/disarm passcode or COMMAND 1 (D8112G2 excluded). Unexpanded reporting, system armed by arm/disarm passcode or CMD 1. AREA armed by user with the ID in the second line of the report Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report.
D6500 Mode: SIA Mode:
364. Forced Close Early by Area(ID not reported)
Printer:
365. Forced Close Early by Area
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
366. Force Close Late by Account
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NriaCF]
F CLOSE EARLY AREA=a
dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCF]
dd/dd tt:tt Lxx ACC aaa CLOSING ZN I dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst [#aaaa|NCLi] [#aaaa|NCW]
367. Force Close Late by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCF]
F CLOSE LATE
368. Force Close Late by Account
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCF]
F CLOSE LATE ID=iii
369. Force Close Late by Account (ID not reported)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa CLOSING REPORT dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst [#aaaa|NCL] [#aaaa|NCW]
Bosch Security Systems | 1/05 | 4998122703D
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140 1,
1, D7112
2, i = user id.
1, D7112
1, D7112
2, D7112
93
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
370. Forced Close Early by Area (users > 254) 371. Force Close Early (7112 Only) 372. Force Close Late (7112 Only) 373. Forced Close Late by Area
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY h1rrlssssssaaaasCsssst [#aaaa|NCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE h1rrlssssssaaaasCsssst [#aaaa|NCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiCF]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
374. Forced Close Late by Area (users > 254) 375. Forced Close Perimeter Delay by Area (ID not reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaNF]
376. Forced Close Perimeter Delay by Area (ID not reported)
Printer:
377. Forced Close Perimeter Delay by Area (User ID# > 254 reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNF]
378. Forced Close Perimeter instant by Area
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiNF]
94
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaNF]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed.
A user with the ID in the second line of the report has delay armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed.
1, D7112
A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed.
A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed.
1, D7112
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
379. Forced Close Perimeter instant by Area(ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST h1rrlssssssaaaasCsssst [#aaaa|NriaNF]
A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed.
1.
380. Forced Close Perimeter Instant by Area (User ID# > 254 reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNF]
381. Force Closing by Account
Printer:
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report.
2,
The system armed/disarmed with a passcode or COMMAND 1 reporting no User ID (D8112G2 excluded). AREA armed by user with the ID in the second line of the report
2,
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
382. Force Closing by Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst [#aaaa|NCLi] [#aaaa|NCW]
CLOSING ZN I WAS FORCE ARMED
dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst [#aaaa|NCL] [#aaaa|NCW]
CLOSING REPORT WAS FORCE ARMED
I = user id.
D7112
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 383. Forced Closing by Area
Printer: D6500 Mode: SIA Mode:
384. Forced Closing by Area
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiNF]
A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed.
dd/dd tt:tt Lxx ACC aaa CLOSING ZN z dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCssszt h1rrlssssssaaaasWsssst [#aaaa|NCLz] [#aaaa|NCW]
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report.
Bosch Security Systems | 1/05 | 4998122703D
2, z = area number
95
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
385. Forced Closing by Area (no area) (users 254) 387. Forced Point
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa ID=iii h1rrlssssssaaaasCsiiit [#aaaa|NidiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasTspppt [#aaaa|Nria/idiiiXWppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
388. Forced Point
Printer: D6500 Mode: SIA Mode:
389. Forced Point (ID not reported)
390. Forced Point
Printer: D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed.
10,
dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaXWppp]
The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed.
1,
dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaXWppp]
The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed.
1,
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaXWpppp] dd/dd tt:tt Lxx ACC aaaa PROG ACCESS BAD +++ ACC aaaa SDI=ddd h1rrlssssssaaaasTsF01t [#aaaa|NpidddLU]
393. Invalid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssFt [#aaaa|NBTF]
394. Invalid Remote Access (phone not reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ ACC aaaa PHONE#=5 h1rrlssssssaaaasTsssFt [#aaaa|Nph5RU]
395. Invalid Remote Access (from Call Back)
Printer:
391. Forced Point (point > 254)
392. Invalid Local Access
96
Printer: D6500 Mode: SIA Mode: Printer:
Explanation
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
TROUBLE ZN
F
D7112
6, D9112
6, D7112
9.
An unsuccessful attempt was made to locally access the account through the supervised keypad or other serial device specified in the second line of the report. Abnormal RAM session termination or beginning of the Command 58 Fire Test. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report.
D9112
2.
D9112
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ACC aaaa PH#=hh h1rrlssssssaaaasTsssFt [#aaaa|NphhhRU]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
396. Invalid Remote Access (no call back)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt [#aaaa|NpRU]
397. Invalid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt [#aaaa|NphhRU]
398. Invalid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt [#aaaa|NRU]
An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report.
399. Invalid Report
Printer: D6500 Mode: SIA Mode: Printer:
INVALID REPORT
LATE TO OPEN ID=iii
A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window.
1.
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlsssssssssssXss26t [#aaaa|NYN] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit [#aaaa|NidiiiOJ]
401. Late Opening By Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NOJ]
LATE TO OPEN
A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window.
1,
402. Late Opening By Area
Printer:
dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOJ]
A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window.
1,
LATE TO OPEN AREA=a
A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window.
1,
CLOSING LATE
400. Late Opening By Account
D6500 Mode: SIA Mode:
403. Late Opening By Area (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NriaOJ]
404. Late To Close (7112 Only)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst [#aaaa|NCJ] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NOJ] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas*sssst [#aaaa|NLF] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas*sssst [#aaaa|NLF]
405. Late To Open (7112 Only) 406. Listen In
407. Listen In
Bosch Security Systems | 1/05 | 4998122703D
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140 D9112
D7112
D7112
D7112
D7112
LATE TO OPEN
LISTEN IN
LISTEN jj
97
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
408. Log Threshold
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsD01t [#aaaa|NJL]
409. Log Overflow
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa LOG OVERFLOW h1rrlssssssaaaasAsD01t [#aaaa|NJO] +++ ACC aaaa LOG OVERFLOW h1rrlssssssaaaaSLsssst [#aaaa|OJO]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
+++ ACC aaaa LOG THRESHOLD h1rrlssssssaaaaSBsssst [#aaaa|OJL] dd/dd tt:tt LOW BATTERY RCVR rr h1rrssssssssssssXss11t [NYT] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasLspppt [#aaaa|NriaZAppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasLppppt [#aaaa|NriaaZApppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRLspppt [#aaaa|NriaZRppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRLppppt [#aaaa|NriaaZRpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt [#aaaa|NriaUZppp]
410. Log Overflow Since Last Call
411. Log Threshold Since Last Call 412. Low Battery
413. Low Temperature (points < 255) 414. Low Temperature (points > 254) 415. Low Temperature Restore (points < 255) 416. Low Temperature Restore (points > 254) 417. Missing Alarm
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
418. Missing Alarm
419. Missing Alarm (Area Not Reported) 420. Missing Alarm
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
98
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt [#aaaa|NBAz] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasMspppt [#aaaa|NUZppp]
Explanation
LOG THRESHOLD
ALARM
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The log in the control panel reached the programmed percent full point programmed in item Log % Full (default Log Full = 85%).
The log in the control panel reached the programmed percent full point programmed in item Log % Full (default Log Full = 85%).
5.
5.
The POINT in the AREA specified in the second line of the report is missing.
ZN z
1, 10.
2, 9.
MISSING ALARM POINT=ppp
The POINT in the AREA specified in the second line of the report is missing.
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt [#aaaa|NriaUZppp]
The POINT in the AREA specified in the second line of the report is missing.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
421. Missing Alarm (points > 254)
422. Missing Alarm - Cross Point (points < 255)
423. Missing Alarm - Cross Point (points > 254)
424. Missing Alarm with Recent Closing Created due to alarm within 5 min of close (points > 254, users 254, users >254)
Printer:
426. Missing Alarm - Exit Error (points > 254, users < 255)
Printer:
427. Missing Alarm - Exit Error (points > 254, users > 254) 428. Missing Fire Supervision
429. Missing Fire Supervision (points < 255)
430. Missing Fire Supervision (points > 254) 431. Missing Fire Supervision (points > 254)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasMspppt [#aaaa|NriaXMppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|NriaaXMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|Nriaa/idiiiCMpppp]
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|Nriaa/idiiiiCMpppp]
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|Nriaa/idiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt [#aaaa|Nriaa/idiiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt [#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt [#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt [#aaaa|NriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt [#aaaa|NriaaFZpppp]
Bosch Security Systems | 1/05 | 4998122703D
99
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
432. Missing Supervision
433. Missing Supervision (points > 254) 434. Missing Tbl
435. Missing Trouble 436. Missing Trouble
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaMTspppt [#aaaa|NriaBZppp] dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaMTppppt [#aaaa|NriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE* ZN zyy h1rrlssssssaaaasVszyyt [#aaaa|NUYzyy] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt [#aaaa|NriaUYppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
437. Missing Trouble (Area Not Reported)
Printer:
438. Missing Trouble (for use with Keyfob device) (points < 255)
Printer:
439. Missing Trouble (points < 255) 440. Missing Trouble (for use with Keyfob device) (points > 254) 441. Missing Trouble (points > 254) 442. MPU Version
443. No Entry (Door Secured)
100
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasVspppt [#aaaa|NUYppp]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
2.
Trouble condition received from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report.
1, 10.
Trouble condition received from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report.
dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasVsD10t [#aaaa|NidiiiUY] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt [#aaaa|NriaUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt [#aaaa|NriaUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt [#aaaa|NriaaUYpppp] dd/dd tt:tt 6500 MPU vv.vv RCVR rr h3rrs 6500 MPU vv.vvt [A6500 MPU vv.vv] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDZppp] or [#aaaa|Nria/idiii/ssxDZppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
444. No Entry (Interlock Deny)
Printer:
445. No Entry (points < 255, user < 255) (AntiPassback)
Printer:
446. No Entry (points > 254, users < 254) (Wrong Arming State)
Printer:
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDWppp] or [#aaaa|Nria/idiii/ssxDWppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDIppp] or [#aaaa|Nria/idii/ssxDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDQpppp]
447. No Entry (point > 254, users < 255) (AntiPassback)
Printer:
448. No Entry (points > 254, users < 255) (Door Secured)
Printer:
449. No Entry (points > 254, users < 255) (Interlock Deny)
Printer:
450. No Entry (points > 254, users < 255) (No Rights in Area)
Printer:
451. No Entry (points > 254, users < 255) (Outside Time Window)
Printer:
452. No Entry (points > 254, users > 254) (AntiPassback)
Printer:
453. No Entry (points > 254, users > 254) (Door Secured)
Printer:
454. No Entry (points > 254, users > 254) (Interlock Deny)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDIppp] or [#aaaa|Nriaa/idiii/ssxDIpppp]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The Modifier “/ssx” refers to the Data Type Address, not the Modifiers “idiii,” or “piddd”
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiDZpppp] or [#aaaa|Nriaa/idiii/ssxDZpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiDWpppp] or [#aaaa|Nriaa/idiii/ssxDWpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDVpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiDPpppp] or [#aaaa|Nriaa/idiii/ssxDPpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDIppp] or [#aaaa|Nriaa/idiii/ssxDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDZpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDWpppp]
Bosch Security Systems | 1/05 | 4998122703D
101
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
455. No Entry (points > 254, users > 254) (No Rights in Area)
Printer:
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDVpppp]
456. No Entry (points > 254, users > 254) (Wrong Arming State)
Printer:
457. No Entry (points > 254, users > 254) (Outside Time Window)
Printer:
458. No Entry (No Rights in Area)
Printer:
459. No Entry (Outside Time Window)
Printer:
460. No Entry (Unknown ID)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiDQpppp] or [#aaaa|Nriaa/idiii/ssxDQpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt [#aaaa|Nriaa/idiiiiDPpppp]
461. No Entry (Wrong Arming State)
Printer:
462. Opening
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDVppp] or [#aaaa|Nria/idiii/ssxDVppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDPppp] or [#aaaa|Nria/idiii/ssxDPppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-UNK ID +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDDppp] or [#aaaa|Nria/idiii/ssxDDppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt [#aaaa|Nria/idiiiDQppp] or [#aaaa|Nria/idiii/ssxDQppp] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT h1rrlssssssaaaasOsssst [#aaaa|NOP]
463. Opening
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa OPENING ZN I h1rrlssssssaaaasOsssit [#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa OPENING ID I h1rrlssssssaaaasOsssit [#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa OPENING ID iyy h1rrlssssssaaaasOsiyyt [#aaaa|NOPiyy] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT h1rrlssssssaaaasOsiiit [#aaaa|NidiiiOP]
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
464. Opening
465. Opening
466. Opening By Account
102
D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
1.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssst [#aaaa|NOP]
OPENING REPORT
468. Opening By Account (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssst [#aaaa|NOP]
OPENING REPORT
469. Opening By Account
Printer: D6500 Mode: SIA Mode: Printer:
467. Opening By Account
470. Opening By Account
D6500 Mode: SIA Mode: 471. Opening by Account from Alarm 472. Opening By Area
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
473. Opening By Area
Printer: D6500 Mode: SIA Mode:
474. Opening by Area
475. Opening By Area (ID not reported) 476. Opening by Area (users > 254) 477. Opening by Area (users < 255) 478. Opening by Area from Alarm
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssit [#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit [#aaaa|NidiiiOP]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
1,
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
2,
OPENING ZN I
D7112
9, D7112 2, 9.
OPENING REPORT ID=iii
dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ ACC aaaa ID=iii h1rrlssssssaaaasOsiiit [#aaaa|NidiiiOR] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOP] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasOsssst [#aaaa| NriaOP] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NriaOP]
Explanation
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
System disarmed. A user with the ID in the second line of the report disarmed the AREA. System disarmed. A user with the ID in the second line of the report disarmed the AREA.
1.
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
1,
OPENING REPORT AREA=a
OPENING REPORT AREA=a
D7112.
dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=aa ID=iii h1rrlssssssaaaasOiiit [#aaaa|Nriaa/idiiiOP] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst [#aaaa|NriaOR]
Bosch Security Systems | 1/05 | 4998122703D
103
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
479. Opening by Area from Alarm (users > 254) 480. Opening Early by Area
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOR] dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOK]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
481. Opening Early by Area
482. Opening Early by Area (users > 254) 483. Opening Early by Area from Alarm 484. Opening Early by Area from Alarm (users > 254) 485. Opening Late by Area
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
486. Opening Late by Area
487. Opening Late by Area (users > 254) 488. Opening Late by Area from Alarm 489. Opening Late by Area from Alarm (users > 254) 490. Output State (outputs < 255)
491. Output State (outputs > 254)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
104
dd/dd tt:tt Lxx ACC aaaa EARLY +++ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NriaOK] dd/dd tt:tt Lxx ACC aaaa EARLY +++ACC aaaa AREA=aa h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOK] dd/dd tt:tt Lxx ACC aaaa OP ERLY +++ACC aaaa h1rrlssssssaaaasOsssst [#aaaa|NriaOH] dd/dd tt:tt Lxx ACC aaaa OP ERLY +++ACC aaaa AREA=aa h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOH] dd/dd tt:tt Lxx ACC aaaa LATE +++ ACC aaaa AREA=a h1rrlssssssaaaasOsiiit [#aaaa|Nria/idiiiOJ]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window.
TO OPEN AREA=a
TO OPEN ID=iiii
FRM-ALM AREA=a
FRM-ALM ID=iiii
TO OPEN ID=iii
A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window.
dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst [#aaaa|NriaOJ] dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOJ] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst [#aaaa|NriaOL] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit [#aaaa|Nriaa/idiiiiOL] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasTsD47t [#aaaa|NOUuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasTsD47t [#aaaa|NOUuuuu]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
492. Output State Restore (outputs < 255) 493. Output State Restore (outputs > 254) 494. Paper In
495. Paper Out
496. Parameters Changed 497. Parameter Checksum Fail
498. Parameter Checksum Fail 499. Parameter Checksum Fail (SDI Device and Point reported) 500. Parameters Checksum Fail Since Last Call 501. Perimeter Delay (Area Not Reported) 502. Perimeter Delay by Area
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasRsD47t [#aaaa|NOVuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasRsD47t [#aaaa|NOVuuuu] dd/dd tt:tt PAPER IN RCVR rr h1rrssssssssssssXss15t [NVI] dd/dd tt:tt PAPER OUT RCVR rr h1rrssssssssssssXss16t [NVO] dd/dd tt:tt Lxx ACC aaaa PARAMS CHANGED h1rrlssssssaaaasNsD02t [#aaaa|NYG] dd/dd tt:tt Lxx ACC aaaa PARM CKSUM FAIL h1rrlssssssaaaasTsD15t [#aaaa|NYF]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
503. Perimeter Delay by Area (ID not reported)
Printer:
504. Perimeter Delay by Area (User ID# > 254 reported)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The program in the control panel parameters is corrupt. Send service immediately.
D9112
dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM h1rrlssssssaaaasTsD15t [#aaaa|NYF] dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasTspppt [#aaaa|NpidddYFppp] +++ ACC aaaa PARAMS BAD CKSM h1rrlssssssaaaaSMsssst [#aaaa|OYF] dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit [#aaaa|NidiiiNL]
5.
A user with the ID in the second line of the report delay armed the perimeter of the AREA.
dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiNL]
A user with the ID in the second line of the report delay armed the perimeter of the AREA.
1.
dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaNL]
A user with the ID in the second line of the report delay armed the perimeter of the AREA.
1, D7112
dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNL]
Bosch Security Systems | 1/05 | 4998122703D
105
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
505. Perimeter Delay by Area, User Defined (User Defined ID# > 254 reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNM]
506. Perimeter Instant (Area Not Reported)
Printer:
507. Perimeter Instant by Area
Printer:
508. Perimeter Instant by Area (ID not reported)
Printer:
509. Perimeter Instant by Area (ID not reported)
Printer:
510. Perimeter Instant by Area (User ID# > 254 reported)
Printer:
511. Perimeter Instant by Area, User Defined (User ID# > 254 reported)
Printer:
512. Phone Line Fail (Line 1)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit [#aaaa|NidiiiNL]
A user with the ID in the second line of the report armed the perimeter of the AREA.
dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit [#aaaa|Nria/idiiiNL]
A user with the ID in the second line of the report armed the perimeter of the AREA.
1.
dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa ID=ii h1rrlssssssaaaasCsssst [#aaaa|NriaNL]
A user with the ID in the second line of the report armed the perimeter of the AREA.
1,
dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst [#aaaa|NriaNL]
A user with the ID in the second line of the report armed the perimeter of the AREA.
D7112
dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit [#aaaa|Nriaa/idiiiiNM] PHONE LINE FAIL PHONE LINE=1
The premises phone line in the second line of the report does not operate.
D7112
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssBt [#aaaa|NLT1]
513. Phone Line 1 Fail
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssBt [#aaaa|NBTB]
TROUBLE
ZN
B
Primary Phone Line failure (two-line system).
2.
514. Phone Line 2 Fail
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssCt [#aaaa|NBTC]
TROUBLE
ZN
C
Secondary Phone Line failure (two-line system).
2.
515. Phone Line Fail (Line 2)
Printer:
PHONE LINE FAIL PHONE LINE=2
The premises phone line in the second line of the report does not operate.
D7112
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssCt [#aaaa|NLT2]
516. Phone Line 1 Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssBt [#aaaa|NURB]
RESTORAL ZN
Primary Phone Line is restored (two line system).
2.
106
B
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
517. Phone Line Restoral (Line 1)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssBt [#aaaa|NLR1]
The premises line in the second line of the report is restored.
D7112
518. Phone Line 2 Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssCt [#aaaa|NURC]
Secondary Phone Line is restored (two line system).
2.
519. Phone Line 2 Restoral (Line2)
Printer:
The premises line in the second line of the report is restored.
D7112
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PHONE RESTORAL +++ ACC aaaa PHONE LINE=2 h1rrlssssssaaaasRsssCt [#aaaa|NLR2] dd/dd tt:tt Lxx PHONE RESTORED RCVR rr h1rrlsssssssssssXsss6t [NLR dd/dd tt:tt Lxx PHONE TROUBLED RCVR rr h1rrlsssssssssssXsss5t [NLT] dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE h1rrlssssssaaaasTsssDt [#aaaa|NET]
523. Point Bus Fail
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssDt [#aaaa|NBTD]
Zonex service required message: indicates a trouble condition on the data lines wiring from the POPEX Module to the POPITs. Trouble on wiring connecting control panel and keypads. Point bus, supervised keypad, printer, or other serial device trouble.
2.
524. Point Bus Fail (area reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE +++ACC aaaa AREA=aa h1rrlssssssaaaasTsssDt [#aaaa|NriaaET] +++ ACC aaaa PT BUS TROUBLE h1rrlssssssaaaaSTsssst [#aaaa|OET]
Trouble on the data line for the points or keypads.
5.
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL h1rrlssssssaaaasRsssDt [#aaaa|NER] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN D h1rrlssssssaaaasRsssDt [#aaaa|NURD]
520. Phone Restored 521. Phone Troubled 522. Point Bus Fail
525. Point Bus Fail Since Last Call 526. Point Bus Restoral 527. Point Bus Restoral
Bosch Security Systems | 1/05 | 4998122703D
PHONE RESTORAL PHONE LINE=1
RESTORAL
TROUBLE
ZN
ZN
C
D
Trouble on the data line for the points or keypads.
Data line for the points or keypads restored. Zonex restoral message: indicates a trouble condition on the wiring from the POPEX Module to the POPITs was cleared. Wiring connecting the control panel and keypads restored. Point bus, supervised keypad, printer, or other serial device was restored.
2.
107
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
528. Point Bus Restoral (area reported) 529. Point Bypass
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsssDt [#aaaa|NriaaER] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasNspppt [#aaaa|Nria/idiiiUBppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
530. Point Bypass
531. Point Bypass (Area and ID Not Reported)
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
532. Point Bypass (ID not reported)
Printer:
533. Point Bypass (point < 255)
Printer:
534. Point Bypass (point < 255) (fire point)
535. Point Bypass (point > 254) (fire point)
536. Point Bypass (point < 255) (supervisory point) 537. Point Bypass (point > 254) (supervisory point) 538. Point Bypass (point < 255) (waterflow point)
108
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NUBppp]
dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaUBppp]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID.
1, D7112
9, D7112 The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID. The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID.
1, D7112
dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaFBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaFBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaSBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaSBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaWBppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
539. Point Bypass (point > 254) (waterflow point) 540. Point Bypass (point > 254)
541. Point Closing
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaWBpppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
542. Point Closing (points > 254)
543. Point Opening
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
544. Point Opening (points > 254)
545. Point Text
546. Power Fail
547. Programmer Bypass
548. Programmer Bypass 549. Printer Off Line 550. Printer On Line
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA in the second line of the report was armed.
1,
The POINT in the AREA in the second line of the report was armed.
1,
dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasCspppt [#aaaa|NriaCZppp]
10.
dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasCppppt [#aaaa|NriaaCZpppp] dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasOspppt [#aaaa|NriaOZppp]
10.
dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasOppppt [#aaaa|NriaaOZpppp] +++ ACC aaaa (point text) no message no message dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasPsssst [#aaaa|NAT]
D9112
AC FAILED
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt [#aaaa|Nria/pidddUBppp]
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt PRINTER OFFLINE RCVR rr h1rrssssssssssssXss20t [NVZ] dd/dd tt:tt PRINTER ONLINE RCVR rr h1rrssssssssssssXss19t [NVY]
Bosch Security Systems | 1/05 | 4998122703D
No AC power. Control panel is running on battery power only. This report is sent along with the next report transmitted. It is not transmitted independently. The POINT in the AREA in the second line of the report is faulted, and was bypassed by a programmer with the specified serial device number when the system was armed.
1, D9112
9, D9112
109
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
551. Printer Restoral 552. Printer Status – Off Line
553. Printer Status – On Line
554. Printer – Paper In
555. Printer – Paper Out
556. Printer Trouble 557. Printer Version 558. Programmer Bypass (point > 254) 559. Programmer In 560. Programmer Out 561. Pulse Error
562. RAM Access Fail (Call Back)
563. RAM Access Fail (No Call Back)
110
Device/Mode
Display
Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt PRINTER RESTORAL RCVR rr h1rrssssssssssssXss22t [NVR] dd/dd tt:tt Lxx ACC aaaa PRINTR-OFF LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst [#aaaa|NpidddVZ] dd/dd tt:tt Lxx ACC aaaa PRINTER-ON LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst [#aaaa|NpidddVY] dd/dd tt:tt Lxx ACC aaaa PRINTR-PAPER IN +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst [#aaaa|NpidddVI] dd/dd tt:tt Lxx ACC aaaa PRNTR-PAPER OUT +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst [#aaaa|NpidddVO] dd/dd tt:tt PRINTER TROUBLE RCVR rr h1rrssssssssssssXss21t [NVT] dd/dd tt:tt PRINTER vv.vv RCVR rr h3rrs PRINTER vv.vvt [APRINTER vv.vv] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaasNppppt [#aaaa|Nriaa/pidddUBpppp] dd/dd tt:tt PROGRAM MODE IN RCVR rr h1rrssssssssssssXss17t [NLB] dd/dd tt:tt PROGRAM MODE OUT RCVR rr h1rrssssssssssssXss18t [NLD] dd/dd tt:tt Lxx PULSE ERROR # ## RCVR rr h3rrlPULSE ERROR # ##t [APULSE ERROR # ##] dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt [#aaaa|NRU]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ ACC aaaa PHONE#=h h1rrlssssssaaaasTsssFt [#aaaa|NphhRU]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
564. RAM Access OK (from Call Back)
Printer:
RAM ACCESS OK PHONE#=h
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NphhRS]
The account was contacted by a RAM on the PHONE# specified in the second line of the report.
565. RAM Access OK (via Phone Line)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NRS]
RAM ACCESS OK
The account was contacted by a RAM on the PHONE# specified in the second line of the report.
566. Re-Boot
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RE-BOOT h1rrlssssssaaaasNsD14t [#aaaa|NRR] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN 9 h1rrlssssssaaaasRsss9t [#aaaa|NUR9]
The control panel was reset.
567. Re-Boot
Explanation
Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM.
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
2, D9112
Control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be Battery Restoral Report for D7112). 568. Re-Boot (SDI Device and Point reported)
Printer:
569. Reject Command
Printer: D6500 Mode: SIA Mode:
570. Relay Reset (by Programmer)
Printer:
571. Relay Reset (by RAM)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: 572. Relay Reset (by SKED)
573. Relay Reset (by USER)
Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RE-BOOT +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt [#aaaa|NpidddRRppp] dd/dd tt:tt REJECT COMMAND RCVR rr h3rrsREJECT COMMANDsst [REJECT COMMAND] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD22t [#aaaa|NpidddROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY REMOTE +++ ACC aaaa RELAY#=rrr h1rrlssssssaaaasNsD24t [#aaaa|NROrrr]
The control panel was reset.
The RELAY specified in the second line of the report was reset.
The RELAY specified in the second line of the report was reset.
dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY SKED +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD20t [#aaaa|NaikkROrrr]
The RELAY specified in the second line of the report was reset.
dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY USER +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD18t [#aaaa|NidiiiROrrr]
The RELAY specified in the second line of the report was reset.
Bosch Security Systems | 1/05 | 4998122703D
111
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
574. Relay Reset (relay 254) (by USER) 575. Relay Reset (relay > 254) (by SKED)
576. Relay Reset (relay > 254) (by Programmer) 577. Relay Reset (relay > 254) (by RAM)
578. Relay Reset (relay >254, user < 255) (by USER) 579. Relay Reset (relay >254, user > 254) (by USER) 580. Relay Reset by Sked
581. Relay Reset by User
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD18t [#aaaa|NidiiiiROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD20t [#aaaa|NaikkkROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD22t [#aaaa|NpidddROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD24t [#aaaa|NROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD18t [#aaaa|NidiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD18t [#aaaa|NidiiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD20t [#aaaa|NaikkROrrr]
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
582. Relay Set (by Programmer)
583. Relay Set (by RAM)
584. Relay Set (by SKED)
Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
112
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The RELAY specified in the second line of the report was reset.
7,
dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD18t [#aaaa|NidiiiROrrr]
The RELAY specified in the second line of the report was reset.
1,
dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD21t [#aaaa|NpidddRCrrr]
The RELAY specified in the second line of the report was set.
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD23t [#aaaa|NRCrrr]
RELAY SET BY REMOTE RELAY#=rrr
The RELAY specified in the second line of the report was set.
dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY SKED +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD19t [#aaaa|NaikkRCrrr]
The RELAY specified in the second line of the report was set.
D9112
7, D9112
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
585. Relay Set (by USER)
586. Relay Set (relay 254) (by USER) 587. Relay Set (relay > 254) (by Programmer) 588. Relay Set (relay > 254) (by RAM)
589. Relay Set (relay > 254) (by SKED)
590. Relay Set (relay >254, user < 255) (by USER) 591. Relay Set (relay >254, user > 254) (by USER) 592. Relay Set by Sked
593. Relay Set by User
Device/Mode
Display
Explanation
Printer:
dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY USER +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD28t [#aaaa|NidiiiRCrrr]
The RELAY specified in the second line of the report was set.
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
594. Remote Bypass
Printer: D6500 Mode: SIA Mode:
595. Remote Bypass
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD28t [#aaaa|NidiiiiRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD21t [#aaaa|NpidddRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD23t [#aaaa|NRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD19t [#aaaa|NaikkkRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD28t [#aaaa|NidiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD28t [#aaaa|NidiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD19t [#aaaa|NaikkRCrrr]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The RELAY specified in the second line of the report was set.
7,
dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD28t [#aaaa|NidiiiRCrrr]
The RELAY specified in the second line of the report was set.
1,
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp PHONE#=h h1rrlssssssaaaasNspppt [#aaaa|Nria/phhUBppp]
The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through through the specified phone line.
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt [#aaaa|NBTz]
Bosch Security Systems | 1/05 | 4998122703D
TROUBLE
D9112
7, D9112
ZN
z
1, D9112
9, D9112
113
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Printer:
598. Remote Reset
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp PH#=hh h1rrlssssssaaaasNppppt [#aaaa|Nriaa/phhhUBpppp] dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa REMOTE RESET h1rrlssssssaaaasNsD11t [#aaaa|NRN]
The control panel power was reset using RAM.
D9112
599. Remote Reset
Printer:
dd/dd tt:tt Lxx ACC aaa RESTORAL
D9112
D6500 Mode: SIA Mode:
h1rrlssssssaaaasRsss9t [#aaaa|NUR9]
Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM, control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be battery restoral report for D7112).
600. Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT h1rrlssssssaaaasRsssst [#aaaa|NUR]
601. Restoral
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRssszt [#aaaa|NURz] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRszyyt [#aaaa|NURzyy] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRssxxt [#aaaa|NURxx] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRss16t [#aaaa|NUR16] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRspppt [#aaaa|NBRppp]
596. Remote Bypass (Call back) (point > 254) 597. Remote Bypass (No Call back) (point > 254)
602. Restoral
603. Restoral
604. Restoral
605. Restoral (Area Not Reported)
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
ZN
9
RESTORAL ZN
z
2, 9.
RESTORAL ZN zyy
RESTORAL ZN
xx
RESTORAL ZN
16
RESTORAL REPORT POINT=ppp
Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored. Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored.
606. Restoral (From Trouble, Missing, NonFire Supervision)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaBRppp]
607. Restoral Fire
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaaHsssszt [#aaaa|NFRz]
114
Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored.
RESTORAL FR z
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
608. Restoral from Alarm
609. Restoral from Alarm (no area) 610. Restoral from Alarm (points > 254) 611. Restoral (user < 255) (for use with Keyfob device) (from trouble, missing, nonfire supervision)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaBHppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
612. Restoral (points > 254) (from trouble, missing, nonfire supervision)
Printer:
613. RF Battery Restore (Area Not Reported)
Printer:
D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NBHppp] dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt [#aaaa|NriaaBHpppp] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t [#aaaa|NidiiiUR]
dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt [#aaaa|NriaaBRpppp]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NXRppp]
The RF POINT transmitter in the AREA in the second line of the report was restored from a low battery
614. RF Interference
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF INTERFERENCE h1rrlssssssaaaasTsD08t [#aaaa|NET]
RF interference was detected in premises RF system.
615. RF Low Battery (Area Not Reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTspppt [#aaaa|NXTppp]
The RF POINT transmitter in the AREA in the second line of the report has a low battery.
616. RF Receiver Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF RCVR RESTORE h1rrlssssssaaaasRsD17t [#aaaa|NER]
617. RF Receiver Restoral from Trouble
Printer:
dd/dd tt:tt Lxx ACC aaaa RCVR TBL RESTOR +++ ACC aaaa SDI=ddd h1rrlssssssaaaasRsD17t [#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPER +++ ACC aaaa SDI=ddd h1rrlssssssaaaasXss35t [#aaaa|NpidddXS] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPR REST +++ ACC aaaa SDI=ddd h1rrlssssssaaaasXss36t [#aaaa|NpidddXJ]
618. RF Receiver Tamper
619. RF Receiver Tamper Restore
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Bosch Security Systems | 1/05 | 4998122703D
RF BATTERY LOW POINT=ppp
The premises RF receiver was restored from a trouble condition.
D7112
D7112
115
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
620. RF Receiver Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF RCVR TROUBLE h1rrlssssssaaaasTsD17t [#aaaa|NET]
The premises RF receiver is in a trouble condition.
D7112
621. RF Receiver Trouble
Printer:
dd/dd tt:tt Lxx ACC aaaa RCVR TROUBLE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasTsD17t [#aaaa|NpidddET] +++ ACC aaaa RF RCVR TROUBLE h1rrlssssssaaaaSTsssst [#aaaa|OET]
The premises RF receiver is in a trouble condition
5.
622. RF Receiver Trouble Since Last Call 623. RF Tamper Trouble (Area Not Reported) 624. RF Transmitter Battery Restore 625. RF Transmitter Battery Restore (for use with Keyfob device) (user < 255)
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
626. RF Transmitter Battery Restore (for use with Keyfob device) (user > 254)
Printer:
627. RF Transmitter Battery Restore (points > 254)
Printer:
628. RF Transmitter Low Battery
Printer:
629. RF Transmitter Low Battery (points > 254) 630. RF Transmitter Low Battery (for use with Keyfob device) (user < 255) 631. RF Transmitter Low Battery (for use with Keyfob device) (user > 254)
116
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NTTppp] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsD10t [#aaaa|NpidddXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t [#aaaa|NpidddXR]
dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasRsD10t [#aaaa|NidiiiiXR]
dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt [#aaaa|NriaaXRpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD10t [#aaaa|NpidddXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasTsD10t [#aaaa|NidiiiXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasTsD10t [#aaaa|NidiiiiXT]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
632. RF Transmitter Tamper Alarm (points > 254) 633. RF Transmitter Tamper Restoral (Area Not Reported)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa RF TAMPER ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt [#aaaa|NriaaTApppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NTRppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
634. RF Transmitter Tamper Restoral (points > 254)
Printer:
635. RF Transmitter Tamper Trouble (points > 254)
Printer:
636. SDI Bus Restore (Ground Fault)
Printer:
637. SDI Bus Restore (used by preOMNI panels) 638. SDI Device AC Failure (used by postOMNI panels) 639. SDI Device AC Restore (used by postOMNI panels) 640. SDI Device Battery Trouble (used by postOMNI panels)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
641. SDI Device Missing (used by postOMNI panels)
Printer:
642. SDI Device Low Battery (used by postOMNI panels)
Printer:
643. SDI Device Missing Restore (used by postOMNI panels) 644. SDI Device Overcurrent (used by postOMNI panels)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt [#aaaa|NriaaTRpppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaTTpppp] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa GROUND FAULT +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa DEVICE AC FAIL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddEP] dd/dd tt:tt Lxx ACC aaaa DEV AC RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddEQ] dd/dd tt:tt Lxx ACC aaaa DEVICE BAT TRBL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddEB] dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddEM] dd/dd tt:tt Lxx ACC aaaa DEV BAT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddEV] dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddEN] dd/dd tt:tt Lxx ACC aaaa DEV OVERCURRENT +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddYI]
Bosch Security Systems | 1/05 | 4998122703D
117
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
645. SDI Device Overcurrent Restore (used by postOMNI panels)
Printer:
dd/dd tt:tt Lxx ACC aaaa DEV OVERCUR RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddYJ]
646. SDI Device Tamper (used by postOMNI panels)
Printer:
647. SDI Device Tamper Restore (used by postOMNI panels) 648. SDI Device Trouble (used by postOMNI panels) 649. SDI Device Trouble Restore (used by postOMNI panels) 650. SDI Fail
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa DEVICE TROUBLE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa DEV TROUBLE RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddER]
D6500 Mode: SIA Mode:
651. SDI Fail
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssDt [#aaaa|NBTD]
652. SDI Fail (Point reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa SDI FAILURE +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasTspppt [#aaaa|NpidddETppp]
653. SDI Fail Since Last Call
Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
118
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa DEVICE TAMPER +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt [#aaaa|NpidddES] dd/dd tt:tt Lxx ACC aaaa DEV TAMPER REST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddEJ]
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssDt [#aaaa|NpidddET]
654. SDI Restoral
Printer:
Explanation
SDI FAILURE SDI=ddd
TROUBLE
ZN
D
+++ ACC aaaa SDI FAILURE h1rrlssssssaaaaSDsssst [#aaaa|OET] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt [#aaaa|NpidddER]
A supervised keypad, printer, or other serial device listed in the second line of the report does not operate. Zonex service required message: indicates a trouble condition on the data lines wiring from the POPEX Module to the POPITs. Trouble on wiring connecting control panel and keypads. Point bus, supervised keypad, printer, or other serial device trouble.
2.
A supervised keypad, printer, or other serial device listed in the second line of the report does not operate. 5.
The supervised keypad, printer, or other serial device listed in the second line of the report was restored.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
655. SDI Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRsssDt [#aaaa|NURD]
656. SDI Restoral
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssDt [#aaaa|NpidddER]
D6500 Mode: SIA Mode:
657. SDI Restoral (Point reported)
Printer:
658. Sensor Reset
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
659. Sensor Reset (ID not reported)
660. Sensor Reset (ID/relay not reported)
661. Sensor Reset (relay > 254, user < 255) 662. Sensor Reset (relay > 254, user >254)
Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
ZN
D
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Zonex restoral message: indicates a trouble condition on the wiring from the POPEX Module to the POPITs was cleared. Wiring connecting the control panel and keypads restored. Point bus, supervised keypad, printer, or other serial device was restored.
2.
SDI RESTORAL SDI=ddd
The supervised keypad, printer, or other serial device listed in the second line of the report was restored.
dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasRspppt [#aaaa|NpidddERppp]
The supervised keypad, printer, or other serial device listed in the second line of the report was restored.
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t [#aaaa|Nria/idiiiXIrrr]
The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown.
1,
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a RELAY#=rrr h1rrlssssssaaaasNsD27t [#aaaa|NriaXIrrr]
The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown.
1,
The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown.
1,
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD27t [#aaaa|NriaXI]
SENSOR RESET AREA=a
7, 8.
7, 8, D7112
7, 8, D7112
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD27t [#aaaa|Nriaa/idiiiXIrrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD27t [#aaaa|Nria/idiiiiXIrrrr]
Bosch Security Systems | 1/05 | 4998122703D
119
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
663. Sensor Reset (relay < 255, user < 255) (OMNI)
Printer:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t [#aaaa|Nria/idiiiXIrrr]
664. Sensor Reset (relay < 255, user > 254) (OMNI)
Printer:
665. Sensor Reset
Printer:
(relay not reported)
666. Sensor Restore (points < 255)
667. Sensor Restore (points > 254)
668. Sensor Trouble (points < 255) 669. Sensor Trouble (points > 254)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
671. Service End
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
672. Service End
D6500 Mode: SIA Mode: Printer:
670. Service End
673. Service Req’d
674. Service Request 675. Service Start
676. Service Start
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
120
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown.
1,
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD27t [#aaaa|Nria/idiiiiXIrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD27t [#aaaa|Nria/idiiiXI]
7, 8, D7112
dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRQspppt [#aaaa|OriaXNppp] dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaaRQspppt [#aaaa|OriaXNppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasQspppt [#aaaa|OriaXKppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasQppppt [#aaaa|OriaaXKpppp] dd/dd tt:tt Lxx ACC aaaa SERVICE END h1rrlssssssaaaasRsssFt [#aaaa|NTE] dd/dd tt:tt Lxx ACC aaaa SERVICE END +++ ACC aaaa AREA=a h1rrlssssssaaaasRsssFt [#aaaa|NriaTE] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NidiiiTE]
SERVICE END ID=iii
dd/dd tt:tt Lxx SERVICE REQUIRED RCVR rr h1rrlsssssssssssXsss1t [NYX] dd/dd tt:tt Lxx ACC aaaa SERVICE REQUEST h1rrlssssssaaaasNsD45t [#aaaa|NYX] dd/dd tt:tt Lxx ACC aaaa SERVICE START h1rrlssssssaaaasTsssFt [#aaaa|NTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiTS]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
677. Service Start
678. Service Start (no area)
679. Service Start (users > 254)
680. Set Time
681. Shunted
682. Shunted
683. Sked Bypass
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsssFt [#aaaa|NriaTS]
SERVICE START AREA=a
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsssFt [#aaaa|NidiiiTS]
SERVICE START ID=iii
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
684. Sked Bypass
685. Sked Bypass (point > 254)
686. Sked Changed
687. Sked Changed (users > 254)
688. Skeds Changed
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
689. Sked Changed
Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA in the second line of the report is faulted, and was bypassed when the system was armed by the specified Sked.
1,
dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt [#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt TIME SET RCVR rr h1rrssssssssssssXsss2t [NJT] dd/dd tt:tt Lxx ACC aaaa SHUNTED ZN z h1rrlssssssaaaasNssszt [#aaaa|NXWz] dd/dd tt:tt Lxx ACC aaaa SHUNTED ZN zyy h1rrlssssssaaaasNszyyt [#aaaa|NXWzyy] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ ACC aaaa AREA=a POINT=ppp SKED=kk h1rrlssssssaaaasNspppt [#aaaa|Nria/aikkUBppp]
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaasNppppt [#aaaa|Nriaa/aikkkUBpppp] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa SKED=kkk h1rrlssssssaaaasNsD06t [#aaaa|NaikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa ID=iiii SKED=kkk h1rrlssssssaaaasNsD06t [#aaaa|Nidiiii/aikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ ACC aaaa ID= iii SKED=kk h1rrlssssssaaaasNsD06t [#aaaa|Nidiii/aikkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ ACC aaaa ID=iii SKED=kk h1rrlssssssaaaasNsD06t [#aaaa|Nidiii/aikkJS]
Bosch Security Systems | 1/05 | 4998122703D
D9112
9, D9112
The Sked in the second line of the report was changed by the user with the specified ID.
D9112
The Sked in the second line of the report was changed by the user with the specified ID.
121
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
690. Sked Executed
Printer: D6500 Mode: SIA Mode:
691. Status: Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa SKED EXECUTED h1rrlssssssaaaasNsD25 [#aaaa|NJR] dd/dd tt:tt Lxx ACC aaaa S: ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSAspppt [#aaaa|OriaBAppp]
692. Status: Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
693. Status: Alarm
Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaa ALARM ZN z h1rrlssssssaaaaSAssszt [#aaaa|OBAz] dd/dd tt:tt Lxx ACC aaaa S:ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt [#aaaa|OriaaBApppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt [#aaaa|OriaaASpppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaaSTppppt [#aaaa|Oriaa/lvlll/vavvvASpppp]
694. Status: Alarm (point > 254)
695. Status: Analog Service (points > 254) 696. Status: Analog Service (points > 254) (Level and Value reported) 697. Status: Close by Area
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode:
698. Status: Close by Area 699. Status: Close by Area 700. Status: Close by Area
SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
701. Status: Door Forced (points > 254) 702. Status: Door Left Open
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
122
STATUS REPORT
dd/dd tt:tt Lxx ACC aaaa S: CLOSING +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst [#aaaa|OriaCL] dd/dd tt:tt Lxx ACC aaa STATUS REPORT h1rrlssssssaaaasSsssst [#aaaa|NYY] dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaaSCssszt [#aaaa|OCLz] dd/dd tt:tt Lxx ACC aaaa S:CLOSING +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst [#aaaa|OriaCL]
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in alarm.
1.
Indicates that the next report is an account status report. 9, D9112
Status report initiated by Skeds or by a user. The AREA in the second line of the report is armed. Indicates that the next report is an account status report. z = area number
Status report initiated by Skeds or by a user. The AREA in the second line of the report is armed.
dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt [#aaaa|OriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSIspppt [#aaaa|OriaDNppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
703. Status: Door Left Open (points > 254) 704. Status: Fire Alarm
705. Status: Fire Alarm (points < 255)
706. Status: Fire Alarm (points < 255)
707. Status: Fire Alarm (points < 255)
708. Status: Fire Alarm (points < 255)
709. Status: Fire Alarm (points > 254) 710. Status: Fire Alarm (points > 254)
711. Status: Fire Alarm (points > 254)
712. Status: Fire Alarm (points > 254)
713. Status: Fire Alarm (points > 254)
714. Status: Fire Missing
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSIppppt [#aaaa|OriaaDNpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt [#aaaa|OriaFAppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt [#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt [#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt [#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt [#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt [#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt [#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt [#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt [#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt [#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt [#aaaa|OriaFYppp]
Bosch Security Systems | 1/05 | 4998122703D
123
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
715. Status: Fire Missing (points > 254) 716. Status: Fire Supervision
717. Status: Fire Supervision (points < 255) 718. Status: Fire Supervision (Water Flow) (point < 255) 719. Status Fire Supervision (Water Flow) (point > 254) 720. Status: Fire Trouble
721. Status: Fire Trouble (points < 255)
722. Status: Fire Trouble (points < 255)
723. Status: Fire Trouble (points < 255)
724. Status: Fire Trouble (points > 254) 725. Status: Fire Trouble (points > 254)
726. Status: Fire Trouble (points > 254)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt [#aaaa|OriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt [#aaaa|OriaFSppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
124
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt [#aaaa|OriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt [#aaaa|OriaFSppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt [#aaaa|OriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt [#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt [#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt [#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt [#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt [#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt [#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt [#aaaa|OriaaFTpppp]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
727. Status: Fire Trouble (points > 254)
728. Status: Missing Alarm
729. Status: Missing Alarm (points > 254) 730. Status: Missing Fire Supervision 731. Status: Missing Fire Supervision (points < 255) 732. Status: Missing Fire Supervision (points > 254) 733. Status: Missing Fire Supervision (points > 254) 734. Status: Missing Supervision
735. Status: Missing Supervision (points > 254) 736. Status: Missing Trouble
737. Status: Missing Trouble (points > 254) 738. Status: Open by Area
739. Status: Open by Area
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt [#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt [#aaaa|OriaUZppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
Explanation
dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt [#aaaa|OriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt [#aaaa|OriaFZppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt [#aaaa|OriaFZppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt [#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt [#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS SUPRVISN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt [#aaaa|OriaBZppp] dd/dd tt:tt Lxx ACC aaaa S:MISS SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt [#aaaa|OriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSVspppt [#aaaa|OriaUYppp]
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSVppppt [#aaaa|OriaaUYpppp] dd/dd tt:tt Lxx ACC aaaa S: OPENING +++ ACC aaaa AREA=a h1rrlssssssaaaaSOsssst [#aaaa|OriaOP]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
D6500 Mode: SIA Mode: Printer:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Bosch Security Systems | 1/05 | 4998122703D
STATUS REPORT
Status report initiated by Skeds or by a user from a keypad: the AREA specified in the second line of the report is disarmed. Indicates that the next report is an Account Status Report.
125
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
740. Status: Open by Area 741. Status:Perimet er Delay by Area 742. Status:Perimet er Delay by Area 743. Status:Perimet er Delay by Area
Device/Mode
Display
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaSOssszt [#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaa OPENING ZN z h1rrlssssssaaaaSOssszt [#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaaa S:PERIM DELAY +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst [#aaaa|OriaNL]
D6500 Mode: SIA Mode:
744. Status:Perimet er Instant by Area
Printer:
Explanation
OPENING
ZN
z
STATUS REPORT
z = area number
Indicates that the next report is an Account Status Report. z = area number
Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report was delay armed.
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa S:PERIM INSTANT +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst [#aaaa|OriaNL]
Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report is armed.
745. Status:Perimet er Instant by Area
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
Indicates that the next report is an Account Status Report.
746. Status:Perimet er Instant by Area
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa OPENING ZN z h1rrlssssssaaaaSOssszt [#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaaa S:PERIM INSTANT +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst [#aaaa|OriaNL]
748. Status Report
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasSssszt [#aaaa|NYY]
749. Status: RF Transmitter Low Battery (points > 254)
Printer:
dd/dd tt:tt Lxx ACC aaaa S:RF BATTRY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt [#aaaa|OriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt [#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt [#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa ALARM ZN z h1rrlssssssaaaaSAssszt [#aaaa|OBAz]
747. Status:Perimet er Instant by Area
750. Status: RF Transmitter Tamper Alarm (points > 254) 751. Status: RF Transmitter Tamper Alarm (points > 254) 752. Status Rpt/Alarm
126
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
STATUS REPORT
STATUS REPORT
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
z = area number
Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report is armed. Indicates that the next report is an Account Status Report.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
753. Status Rpt/Closing
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CLOSING h1rrlssssssaaaaSCsssst [#aaaa|OCL]
REPORT
754. Status Rpt/Closing
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CLOSING h1rrlssssssaaaaSCsssit [#aaaa|OCLi] dd/dd tt:tt Lxx ACC aaaa OPENING h1rrlssssssaaaaSOsssit [#aaaa|OOPi] dd/dd tt:tt Lxx ACC aaaa OPENING h1rrlssssssaaaaSOsssst [#aaaa|OOP]
ID
I
ID
I
757. Status Rpt/Power Fail
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaaSPsssst [#aaaa|OAT]
758. Status Rpt/Restoral
759. Status Rpt/Restoral
755. Status Rpt/Opening 756. Status Rpt/Opening
760. Status Rpt/Trouble 761. Status: Supervision
762. Status: Supervision (points > 254) 763. Status:Transmi tter Low Battery
Explanation
Unexpanded reporting, system armed by arm/disarm passcode or COMMAND 1 (D8112G2 excluded). Unexpanded reporting, system armed by arm/disarm passcode or CMD 1. AREA armed by user with the ID in the second line of the report.
REPORT
System disarmed. A user with the ID in the second line of the report disarmed the AREA.
AC FAILED
No AC power. Control panel is running on battery power only. This report is sent along with the next report transmitted. It is not transmitted independently.
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT h1rrlssssssaaaaSRsssst [#aaaa|OUR]
Unexpanded Restoral Report. Command 41. The POINT in the AREA in the second line of the report was restored.
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
dd/dd tt:tt Lxx ACC aaaa RESTORAL ZN z h1rrlssssssaaaaSRssszt [#aaaa|OURz] dd/dd tt:tt Lxx ACC aaaa TROUBLE ZN z h1rrlssssssaaaaSTssszt [#aaaa|OBTz] dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt [#aaaa|OriaBSppp]
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt [#aaaa|OriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa S:RF BATT LOW +++ ACC aaaa AREA=a RF POINT =ppp h1rrlssssssaaaaSVspppt [#aaaa|OriaXTppp]
Bosch Security Systems | 1/05 | 4998122703D
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Status report. The transmitter at the POINT in the AREA in the second line of the report has a low battery.
127
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
764. Status: Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst [#aaaa|NYY]
765. Status: Trouble
Printer:
dd/dd tt:tt Lxx ACC aaaa S: TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt [#aaaa|OriaBTppp]
D6500 Mode: SIA Mode:
766. Status: Trouble
767. Status: Trouble
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
768. Status: Trouble (point > 254)
769. Supervision (Non-Fire)
770. Supervision (Non-Fire) (points > 254) 771. Supervision (Non-Fire) (points > 254) (Ground Fault) 772. Swinger Bypass
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
128
Explanation
STATUS REPORT
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaaSTssszt [#aaaa|OBTz] dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt [#aaaa|OriaBTppp]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Indicates that the next report is an Account Status Report. Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in a trouble condition.
1.
9, D9112 Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in a trouble condition.
dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt [#aaaa|OriaaBTpppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasJspppt [#aaaa|NriaBSppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt [#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt [#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt [#aaaa|NriaUBppp]
The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point is restored while the system is armed, it returns to the system and is ready to detect faults.
1.
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
773. Swinger Bypass (Area and ID Not Reported)
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNspppt [#aaaa|NUBppp]
774. Swinger Bypass
Printer: D6500 Mode: SIA Mode: Printer:
775. Swinger Bypass (point > 254) 776. Swinger Bypass (7112 Only) 777. Test Failed (Report from UPLINK router indicating “Transceiver Test Failure”)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode:
Explanation
SWINGER BYPASS POINT=ppp
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt [#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt [#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS h1rrlssssssaaaasNsssst [#aaaa|NUB] dd/dd tt:tt Lxx ACC aaaa TEST FAILED +++ ACC aaaa PATH=001 COND=001 +++ ACC aaaa UPLINK. h1rrlssssssaaaasTsD49t [#aaaa|Npt001XX001
Bosch Security Systems | 1/05 | 4998122703D
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point is restored while the system is armed, it returns to the system, and is ready to detect faults. 2, 9.
129
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88: Event
778. Test-Off Normal Expaned
Radionics Modem IIIa2 Messages (continued) Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa TEST-OFF NORMAL +++ACC aaaa LOG THRESHOLD +++ACC aaaa LOG OVERFLOW +++ACC aaaa PT BUS TROUBLE +++ACC aaaa PROG ACCESS OK +++ACC aaaa RF RCVR TROUBLE +++ACC aaaa BAD CALL TO RAM +++ACC aaaa USER TAMPER +++ACC aaaa SDI FAILURE +++ACC aaaa COMM FAILURE +++ACC aaaa EQUIPMENT FAIL +++ACC aaaa AC FAILURE +++ACC aaaa BATTERY MISSING +++ACC aaaa BATTERY LOW +++ACC aaaa PARMS BAD CKSUM +++ACC aaaa PHONE FAIL +++ACC aaaa EXTRA RF POINT +++ACC aaaa RF INTERFERENCE +++ACC aaaa FIRE SUPERVISION +++ACC aaaa ANALOG SERVICE +++ACC aaaa FIRE FAULT +++ACC aaaa CTRL POINT FAULT +++ACC aaaa CHK DEVICE FAULT +++ACC aaaa NETWORK FAILURE
D6500 Mode:
h1rrlssssssaaaasRsssEt h1rrlssssssaaaaSBsssst h1rrlssssssaaaaSLsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSRsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSUsssst h1rrlssssssaaaaSDsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSMsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSEsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSGsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst
+++ACC aaaa
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
RF RCVR TAMPER
h1rrlssssssaaaaSXss35t
130
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
Explanation
Test-Off Normal Expaned
SIA Mode:
[#aaaa|NRY] [#aaaa|OJL] [#aaaa|OJO] [#aaaa|OET] [#aaaa|OLS] [#aaaa|OET] [#aaaa|ORA] [#aaaa|OJA] [#aaaa|OET] [#aaaa|OYC] [#aaaa|OIA] [#aaaa|OAT] [#aaaa|OYM] [#aaaa|OYT] [#aaaa|OYF] [#aaaa|OLT] [#aaaa|OXF] [#aaaa|OXQ] [#aaaa|OFS] [#aaaa|OAS] [#aaaa|OFT] [#aaaa|OBT] [#aaaa|OBT] [#aaaa|ONT]
779. Test Report NonExpanded
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssEt [#aaaa|NRP]
TEST REPORT
780. Time Changed
Printer:
TIME CHANGED
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa ID= iii h1rrlssssssaaaasNsD07t [#aaaa|NidiiiJT]
781. Time Changed
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD07t [#aaaa|NJT]
TIME CHANGED
782. Time Changed (users > 254)
Printer:
TIME CHANGED ID=iiii
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD07t [#aaaa|NidiiiiJT]
783. Transmitter Battery Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRssszt [#aaaa|NURz]
784. Transmitter Battery Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaXRppp]
785. Transmitter Low Battery
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt [#aaaa|NBTz]
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
[#aaaa|OXS]
Bosch Security Systems | 1/05 | 4998122703D
TROUBLE
ZN
ZN
Test Report
D9112
z
z
D7112
The RF POINT transmitter in the AREA in the second line of the report was restored from a low battery.
1, D7112
D7112
131
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
786. Transmitter Low Battery
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Printer:
dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaXTppp]
The RF POINT transmitter in the AREA in the second line of the report has a low battery.
1,
Tamper alarm at the RF POINT in the AREA in the second line of the report.
1,
D6500 Mode: SIA Mode:
D7112
787. Transmitter Tamper Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa TAMPER ALARM +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasAspppt [#aaaa|NriaTAppp]
788. Transmitter Tamper Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt [#aaaa|NBAz]
789. Transmitter Tamper Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRssszt [#aaaa|NURZ]
790. Transmitter Tamper Restoral
Printer:
dd/dd tt:tt Lxx ACC aaaa TAMPER RESTORAL +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasRspppt [#aaaa|NriaTRppp]
The tamper alarm at the RF POINT in the AREA in the second line of the report was restored.
1,
791. Transmitter Tamper Trouble
Printer:
Tamper trouble at the RF POINT in the AREA in the second line of the report.
1,
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa TAMPER TROUBLE +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaTTppp]
792. Transmitter Tamper Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE h1rrlssssssaaaasTssszt [#aaaa|NBTz]
793. Trouble
Printer:
Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition. Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition.
D6500 Mode: SIA Mode:
ALARM
ZN
RESTORAL ZN
ZN
z
D7112
z
D7112
z
SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsssst [#aaaa|NBT]
TROUBLE REPORT
795. Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTssszt [#aaaa|NBTz]
TROUBLE
796. Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaasTszyyt [#aaaa|NBTzyy]
ZN zyy
797. Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaasTssxxt [#aaaa|NBTxx
ZN
xx
798. Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTss16t [#aaaa|NBT16]
TROUBLE ZN
16
The zone number shown (1 to 8) reports a trouble condition.
799. Trouble
Printer:
dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaBTppp]
Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition.
132
D7112
9.
794. Trouble
D6500 Mode: SIA Mode:
D7112
2,
dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt [#aaaa|NriaBTppp]
D6500 Mode:
D7112
ZN
1, 10.
z
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
800.
Trouble (Area Not Reported)
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTspppt [#aaaa|NBTppp]
D6500 Mode: SIA Mode:
801. Trouble (with Ground Fault) (point > 254)
Printer:
802. Trouble Door Forced (point > 254)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: 803. Trouble (point > 254)
Printer:
Explanation
TROUBLE REPORT POINT=ppp
dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaDJpppp]
D6500 Mode: SIA Mode: 804. Trouble Fire
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaaGsssszt [#aaaa|NFTz]
FR
805. Unknown Message
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx UNKNOWN h1rrlsssssssssssXss25t [NYO]
RCVR rr
806. Unverfied Events (points < 255)
Printer:
dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt [#aaaa|NriaBGppp]
807. Unverfied Events (points < 255)
Printer:
808. Unverfied Events (points < 255)
Printer:
809. Unverfied Events (points < 255)
Printer:
810. Unverfied Events (points < 255)
Printer:
811. Unverfied Events (points > 254)
Printer:
812. Unverfied Events (points > 254)
Printer:
813. Unverfied Events (points > 254)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition.
dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaBTpppp]
dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt [#aaaa|NriaaBTpppp]
D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
z
dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt [#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt [#aaaa|NriaBGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt [#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVERFIED EVENT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt [#aaaa|NriaUGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt [#aaaa|NriaaBGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt [#aaaa|NriaaFGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt [#aaaa|NriaaBGpppp]
Bosch Security Systems | 1/05 | 4998122703D
133
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
814. Unverfied Events (points > 254)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt [#aaaa|NriaaFGpppp]
815. User Alarm
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR ALRM ZN h1rrlssssssaaaasUssszt [#aaaa|NPAz]
816. User Alarm 7
Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss7t [#aaaa|Nria/idiiiUA]
A user with the ID in the second line of the report initiated a CMD 7 in the AREA.
1.
A user with the ID in the second line of the report initiated a CMD 7 in the AREA.
1,
z
817. User Alarm 7 (ID not reported)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ ACC aaaa AREA=a h1rrlssssssaaaasUsss7t [#aaaa|NriaUA]
818. User Alarm 7
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt [#aaaa|NBAz]
Printer:
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss7t [#aaaa|NriaUA]
819. User Alarm 7 (area only)
D6500 Mode: SIA Mode: 820. User Alarm 7 (user > 254)
821. User Alarm 9
822. User Alarm 9
(ID not reported) 824. User Alarm 9 (area only)
2, D7112: z=7 D9112: z= as programmed for point (Point Code Digit One =4)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt [#aaaa|NBAz]
Printer:
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss9t [#aaaa|Nria/idiiiPA]
A user with the ID in the second line of the report initiated a CMD 9 in the specified AREA.
1.
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ ACC aaaa AREA=a h1rrlssssssaaaasUsss9t [#aaaa|NriaPA]
A user with the ID in the second line of the report initiated a CMD 9 in the specified AREA.
1,
Printer: D6500 Mode: SIA Mode: Printer:
Printer: D6500 Mode: SIA Mode:
134
z
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: 825. User Alarm 9 (user > 254)
ZN
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss7t [#aaaa|Nriaa/idiiiiUA]
Printer:
D6500 Mode: SIA Mode: 823. User Alarm 9
ALARM
D7112
ALARM ZN
z
2, D7112: z=9 D9112: z= as programmed for point (Point Code Digit One =5)
D7112
dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss9t [#aaaa|NriaPA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss9t [#aaaa|Nriaa/idiiiiPA]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
826. User Code Added
Device/Mode
Display
Printer:
dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD38t [#aaaa|NidiiiJYccc]
D6500 Mode: SIA Mode: 827. User Code Added (users > 254, code > 254)
Printer:
828. User Code Changed
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
829. User Code Changed
Printer: D6500 Mode: SIA Mode:
830. User Code Changed (operator ID not reported)
Printer: D6500 Mode: SIA Mode:
831. User Code Changed (users > 254)
Printer:
832. User Code Deleted
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: 833. User Code Deleted
Printer: D6500 Mode: SIA Mode:
834. User Code Deleted
Printer: D6500 Mode: SIA Mode:
835. User Code Deleted (operator ID not reported)
836. User Code Deleted (User ID# > 254 reported)
Printer: D6500 Mode: SIA Mode:
Printer: D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD38t [#aaaa|NidiiiiJYcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD04t [#aaaa|NidiiiJVccc]
The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID.
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa AREA=a CODE ID=ccc ID=iii h1rrlssssssaaaasNsD04t [#aaaa|Nria/idiiiJVccc]
The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID.
D7112
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa AREA=a CODE ID=ccc h1rrlssssssaaaasNsD04t [#aaaa|NriaJVccc]
The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID.
D7112
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD05t [#aaaa|NidiiiJXccc]
The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown.
D9112
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa AREA= a CODE ID=ccc ID=iii h1rrlssssssaaaasNsD05t [#aaaa|Nria/idiiiJXccc]
The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown.
D7112
The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown.
D7112
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD04t [#aaaa|NidiiiiJVcccc]
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc h1rrlssssssaaaasNsD05t [#aaaa|NJXcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa AREA= a CODE ID=ccc h1rrlssssssaaaasNsD05t [#aaaa|NriaJXccc]
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD05t [#aaaa|NidiiiiJXcccc]
Bosch Security Systems | 1/05 | 4998122703D
135
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
837. User Code Tamper
Device/Mode
Display
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
Printer:
dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD03t [#aaaa|Nria/idiiiJA]
Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown.
1,
Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown.
1,
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER +++ ACC aaaa AREA=a h1rrlssssssaaaasNsD03t [#aaaa|NriaJA]
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER h1rrlssssssaaaasNsD03t [#aaaa|NJA]
Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown.
Printer:
dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD40t [#aaaa|NidiiiJZccc]
D6500 Mode: SIA Mode:
838. User Code Tamper
839. User Code Tamper (Area and ID Not Reported) 840. User Level Set
Printer:
D6500 Mode: SIA Mode: 841. User Level Set (modified user only)
Printer:
842. User Level Set (users > 254)
Printer:
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD40t [#aaaa|NJZcccc]
D7112
USER LEVEL SET CODE ID=cccc
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD40t [#aaaa|NidiiiiJZcccc]
843. User Tamper Since Last Call
Printer: D6500 Mode: SIA Mode:
+++ ACC aaaa h1rrlssssssaaaaSUsssst [#aaaa|OJA]
844. [User Text]
Printer: D6500 Mode: SIA Mode:
+++ ACC aaaa (user text) no message no message
845. Valid Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PROG ACCESS h1rrlssssssaaaasRsF01t [#aaaa|NLS]
846. Valid Access (via SDI Device or D5360)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa PROG ACCESS OK +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsF01t [#aaaa|NpidddLS]
847. Valid Local Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsF01t [#aaaa|NpidddLS]
136
D9112
USER TAMPER
A supervised keypad, printer, or other serial device listed in the second line of the report does not operate.
5.
The account was locally accessed through the supervised keypad or other serial device specified in the second line of the report.
D7112
OK
PROG ACCESS OK
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
848. Valid Local Access Since Last Call
Printer: D6500 Mode: SIA Mode:
+++ ACC aaaa h1rrlssssssaaaaSRsssst [#aaaa|OLS]
849. Valid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|Nph5RS]
850. Valid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NphhRS]
851. Valid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssFt [#aaaa|NURF]
852. Valid Remote Access (2112, 9112)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM ACCESS h1rrlssssssaaaasRsssFt [#aaaa|NRS]
853. Valid Remote Access (from Call Back)
Printer:
RAM ACCESS OK PH#=hh
D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NphhhRS]
854. Valid Remote Access
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NRS]
RAM ACCESS OK
855. Variable Text
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx text as received h3rrltext as receivedt [Atext as rcvd]
856. Walk Test End
Printer:
dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NriaTE]
(phone not reported)
(no call back)
D6500 Mode: SIA Mode: 857. Walk Test End (Invisible Points) (users < 255)
Printer:
858. Walk Test End (Invisible Points) (users > 254)
Printer:
859. Walk Test End (no user)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
The account was locally accessed through the supervised keypad or other serial device specified in the second line of the report.
5.
RAM ACCESS OK PHONE#=5
The account was contacted by a RAM on the PHONE# specified in the second line of the report.
D9112
RAM ACCESS OK
The account was contacted by a RAM on the PHONE# specified in the second line of the report.
D7112
PROG ACCESS OK
RESTORAL
ZN
F
2.
OK
The account was contacted by a RAM on the PHONE# specified in the second line of the report.
D9112
RCVR rr
WALK TEST END AREA=a
dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasRsssFt [#aaaa|Nria/idiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt [#aaaa|Nriaa/idiiiiTE] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt [#aaaa|NriaTE]
Bosch Security Systems | 1/05 | 4998122703D
WALK TEST END AREA=a
137
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
860. Walk Test End (users > 254)
Printer:
dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt [#aaaa|Nriaa/idiiiiTE]
861. Walk Test Point (points > 254)
Printer:
862. Walk Test Point – Fire (points > 254)
Printer:
863. Walk Test Start
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Explanation
dd/dd tt:tt Lxx ACC aaaa WALK TEST PT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt [#aaaa|NriaaBXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TST PT-FIR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt [#aaaa|NriaaFXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiTS]
864. Walk Test Start (Invisible Points) (users < 255)
Printer:
865. Walk Test Start (Invisible Points) (users > 254)
Printer:
866. Walk Test Start (no user)
Printer:
867. Walk Test Start (users > 254)
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a ID=iiii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiiTS]
868. Was Force Armed
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED h1rrlssssssaaaasWsssst [#aaaa|NCW]
Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report.
869. Watchdog Reset
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRsss9t [#aaaa|NUR9]
Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM.
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt [#aaaa|Nria/idiiiTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt [#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt [#aaaa|NriaTS]
ZN
9
Control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be battery restoral report for D7112).
138
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages . Table 88:
Radionics Modem IIIa2 Messages (continued)
Event
Device/Mode
Display
870. Watchdog Reset
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD09t [#aaaa|NYW]
WATCHDOG RESET
The control panel’s watchdog reset. This is a non-emergency troubleshooting message. If it is followed by SDI ##, call Bosch Security Systems Technical Support during normal business hours for help in interpreting the message.
871. Watchdog Reset
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt [#aaaa|NpidddYWppp]
The control panel's watchdog reset. This is a non-emergency troubleshooting message. If it is followed by SDI ##, call Bosch Security Systems Technical Support during normal business hours for help in interpreting the message.
872. +5V Restored
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt +5 RESTORED h1rrssssssssssssXsss4t [NYQ]
RCVR rr
873. +5V Troubled
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt +5 TROUBLED h1rrssssssssssssXsss3t [NYP]
RCVR rr
874. +12V Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt +12 RESTORED h1rrssssssssssssXsss4t [NYQ]
RCVR rr
875. +12V Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt +12 TROUBLED h1rrssssssssssssXsss3t [NYP]
RCVR rr
876. -12V Restoral
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt -12 RESTORED h1rrssssssssssssXsss4t [NYQ]
RCVR rr
877. -12V Trouble
Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt -12 TROUBLED h1rrssssssssssssXsss3t [NYP]
RCVR rr
(SDI Device and Point reported)
Bosch Security Systems | 1/05 | 4998122703D
Explanation
Refer to Section C.1 Bosch Security Systems Zonex and COMEX Translation on page 140
139
D6600 | Computer Interface Manual | Appendix C: Radionics Modem IIIa2 Messages
C.1
Bosch Security Systems Zonex and COMEX Translation
These numbered items correspond to the number in the last column in Table 88 starting on page 61. 1. The D7112/D9112 verifies the user identification and point data formats and sends them to the automation system. If the control panel requests a translation, the D6600 converts point data to Zonex format and user IDs to COMEX format. If there is no request for translation, points and IDs are sent to the automation PC and print on the connected printer with no conversion. Table 90 shows the translation of User IDs and Table 89 shows the translation of point data. Table 89: Point 001-008 009-024 025-040 041-056 057-072 073-088 089-104 105-120 121-136 137-152 153-168 169-184 185-200 201-216 217-232 233-247
Table 90: ID 0 1-5 0-13 14-21 22-29 30-37 38-45 46-53 54-61 62-69 70-249
2. 3. 140
Point to ZONEX Translation ZONEX 100-800 101-116 201-216 301-316 401-416 501-516 601-616 701-716 801-816 117-132 217-232 317-332 417-432 517-532 617-632 717-731
User ID to COMEX Translation COMEX 0 001-005 601-608 701-708 801-808 B01-B08 C01-C08 D01-D08 E01-E08 F01-F08 000
4.
When the D7112 is transmitting a test report in Modem II format, the area number is sent to the automation system if the output format is in SIA communications mode.
Example 1: Log Threshold Since Last Call [#aaaa|OriaJL] 5.
6.
7.
8.
9.
When transmitted by a D7112, the identification number, if any, also prints. Refer to Forced Point in the D9112B Program Entry Guide (P/N: 74-06145-000-D). Not entering a phone number turns off these messages for the event class. All messages in this class exist in a unique event class. For these events, the area denotes the location of the keypad used to initiate the event (see Sensor Reset). BFSK Format: For the D9112, unless otherwise specified, the zone digit "z" uses the "BFSK Zone Code" as a base for a given point. This code is programmed in the control panel by point. The zone digit "i" indicates the most significant digit of the user ID. For the D7112, unless otherwise specified, Table 91 is the basis for the zone digit "z” and ID translation; however, actual IDs only go up to 25.
Table 91:
Reported Zone/ID to Actual Point/ID
Reported Zone/ID Actual Point/ID
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 17 25 33 41
10 18 26 34 42
11 19 27 35 43
12 20 28 36 44
13 21 29 37 45
14 22 30 38 46
15 23 31 39 47
16 24 32 40 48
10. This message reports from a D7112 RF point. The internal or external printer prints the label “RF POINT=” instead of “POINT=” in the second line (Example 2). Example 2: Label RF Point dd/dd tt:tt ql ACC aaaa FIRE ALARM +++ ACC aaaa AREA=a RF POINT=ppp
A D7112 using the Modem II format can transmit these messages. Not used. Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix D: NetCom Messages .
Appendix D: NetCom Messages For networked accounts, Nxx appears instead of Lxx in the line number.
Table 92:
1
2
3
4
5
6
7
8
9
10
NetCom Messages
Event
Device/Mode
Display
Explanation
Alarm-Panel Substitution
Printer:
dd/dd tt:tt Nxx ACC aaaa ALARM-PNL SUBST +++ ACC aaaa PATH=003 COND=007 h1rrlssssssaaaaAsD53t [#aaaa|Npt003AA007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE LOW h1rrlssssssaaaasXss58t [#aaaa|NSC0002] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE RESTORE h1rrlssssssaaaasXss68t [#aaaa|NSC0003]
Condition 007 = Substitution/ Replay
Change Of Status (C900 Voltage Low) Change Of Status (C900 Voltage Restore) Change Of Status (C900 Input Restored) Change Of Status (C900 Input Shorted) Change Of Status (C900 Intercept Disabled)
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Change Of Status (C900 Intercept Enabled)
Printer:
Change Of Status (C900 Output Activated)
Printer:
Change Of Status (C900 Output Deactivated)
Printer:
Change Of Status (C900 Input Open)
Printer:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode:
dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT RESTORED h1rrlssssssaaaasXss91t [#aaaa|NSC0010] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT SHORTED h1rrlssssssaaaasXss89t [#aaaa|NSC0008] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT DISABLED h1rrlssssssaaaasXss93t [#aaaa|NSC0012] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT ENABLED h1rrlssssssaaaasXss92t [#aaaa|NSC0011] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT ACTIVATED h1rrlssssssaaaasXss85t [#aaaa|NSC0006] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT DEACTIVATED h1rrlssssssaaaasXss94t [#aaaa|NSC0007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT OPEN H1rrlssssssaaaasXss90t [#aaaa|NSC0009]
Bosch Security Systems | 1/05 | 4998122703D
141
D6600 | Computer Interface Manual | Appendix D: NetCom Messages
Table 92:
11
12
13
14
15
16
17
18
19
20
21
NetCom Messages (continued)
Event
Device/Mode
Display
Change Of Status (C900 Reboot)
Printer:
dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 REBOOT h1rrlssssssaaaasXss59t [#aaaa|NSC0001] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO FALLBACK h1rrlssssssaaaasXss82t [#aaaa|NSC0005]
Change Of Status (C900 Switched to Fallback)
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
Change Of Status (C900 Switched To Intercept)
Printer:
Command Sent (Activate Output)
Printer:
Command Sent (Deactivate Output) Command Sent (Disable Intercept Mode) Command Sent (Switch To Fallback Mode) Command Sent (Switch To Intercept Mode) Command Sent (Supervision Rate Changed) Communications Fail (Account Disabled By Attack) Communications Fail (Polling Lost)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
142
Explanation
dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO INTERCPT h1rrlssssssaaaasXss87t [#aaaa|NSC0004] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa ACTIVATE OUTPUT h1rrlssssssaaaasXss84t [#aaaa|NCO0005] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa DEACTIVATE OUTPUT h1rrlssssssaaaasXss86t [#aaaa|NCO0006] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa DISABLE INTERCEPT MODE h1rrlssssssaaaasXss83t [#aaaa|NCO0004] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO FALLBACK MODE h1rrlssssssaaaasXss81t [#aaaa|NCO0003] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO INTERCEPT MODE h1rrlssssssaaaasXss88t [#aaaa|NCO0002] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SUPERVISION RATE CHANGED h1rrlssssssaaaasXss66t [#aaaa|NCO0001] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa ACCOUNT DISABLED BY ATTACK +++ ACC aaaa PATH=003 COND=008 h1rrlssssssaaaasTsB03t [#aaaa|Npt003YC008] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasTsB02t [#aaaa|Npt003YC009]
Condition 008 = Attack
Condition 009 = Polling Monitor
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix D: NetCom Messages . Table 92:
22
23
24
25
26
27
28
29
30
NetCom Messages (continued)
Event
Device/Mode
Display
Explanation
Communications Fail Restore (Poll Restore)
Printer:
Condition 009 = Polling Monitor
Dialer Error (Dialing Error)
Printer:
dd/dd tt:tt Nxx ACC aaaa COMM FAIL RESTR +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasNsB02t [#aaaa|Npt003YK009] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa DIALING ERROR h1rrlssssssaaaasXss73t [#aaaa|NYU0003] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa INVALID MESSAGE h1rrlssssssaaaasXss77t [#aaaa|NYU0007] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa MESSAGE UNKNOWN h1rrlssssssaaaasXss76t [#aaaa|NYU0006] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO ACKNOWLEDGMNT RECEIVED h1rrlssssssaaaasXss71t [#aaaa|NYU0001]
Dialer Error (Invalid Message)
Dialer Error (Message Unknown) Dialer Error (No Acknowledgement Received) Dialer Error (Not Dialing)
Dialer Error (No Response to Acknowledgement) Dialer Error (No Response to Handshake) Miscellaneous Message (30 Minutes Since Fallback Command)
D6500 Mode: SIA Mode:
D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NOT DIALING h1rrlssssssaaaasXss72t [#aaaa|NYU0002] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO ACK h1rrlssssssaaaasXss75t [#aaaa|NYU0005] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO HANDSHAKE h1rrlssssssaaaasXss74t [#aaaa|NYU0004] dd/dd tt:tt Nxx ACC aaaa MESSAGE +++ aaaa 30 MIN SINCE FALLBACK CMD h1rrlssssssaaaasXss95t [#aaaa|NMI0001]
Bosch Security Systems | 1/05 | 4998122703D
143
D6600 | Computer Interface Manual | Appendix E: Pulse Output
Appendix E: Pulse Output Table 93 to Table 101 (on page 148) vary depending on the account number specified and the digit parameter programmed using the drop-down menus in Menu Item 3.1.7 Event 3/1 or 4/1 (Figure 22).
Figure 22: D6200 Receiver Software Line Card Configuration
The output of the receiver depends on the reporting digit. Use the settings in Figure 22 that can be changed by the user: • Reporting digits 0 to 9 and A are alarms • Reporting digit B is an opening • Reporting digit C is a closing • Reporting digit D is a cancel • Reporting digit E is a restore Table 93: #
Event
1.
Pulse 3/1 Format
ALARM
Account Number 123
Reporting Digit 4
2.
OPENING
123
B
3.
CLOSING
123
C
4.
CANCEL
123
D
5.
RESTORE
123
E
6.
TROUBLE
123
F
144
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 4 [10]1011sssssss123sAsss4[13] [10]602415[9]00030101[#s123|NBA4][13] DD/DD TT:TT L01 ACCT 123 OPENING [10]1011sssssss123sOssss[13] [10]AA4214[9]00040101[#s123|NOP][13] DD/DD TT:TT L01 ACCT 123 CLOSING [10]1011sssssss123sCssss[13] [10]F94B14[9]00050101[#s123|NCL][13] DD/DD TT:TT L01 ACCT 123 CANCEL [10]1011sssssss123s\ssss[13] [10]FBCE14[9]00060101[#s123|NOC][13] DD/DD TT:TT L01 ACCT 123 RESTORE [10]1011sssssss123sRssss[13] [10]FC2214[9]00070101[#s123|NUR][13] DD/DD TT:TT L01 ACCT 123 TROUBLE [10]1011sssssss123sTssss[13] [10]ACD414[9]00080101[#s123|NBT][13]
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix E: Pulse Output . Table 94: #
Event
7.
Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1
ALARM
Account Number 123
Reporting Digit 45
8.
OPENING
123
B5
9.
CLOSING
123
C5
10.
CANCEL
123
D5
11.
RESTORE
123
E5
12.
TROUBLE
123
F5
Table 95: #
Event
13.
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]720816[9]00090101[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING ZN 5 [10]1011sssssss123sOsss5[13] [10]B0B115[9]00100101[#s123|NOP5][13] DD/DD TT:TT L01 ACCT 123 CLOSING ZN 5 [10]1011sssssss123sCsss5[13] [10]B62215[9]00110101[#s123|NCL5][13] DD/DD TT:TT L01 ACCT 123 CANCEL ZN 5 [10]1011sssssss123s\sss5[13] [10]15E115[9]00120101[#s123|NOC5][13] DD/DD TT:TT L01 ACCT 123 RESTORE ZN 5 [10]1011sssssss123sRsss5[13] [10]98E715[9]00130101[#s123|NUR5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE ZN 5 [10]1011sssssss123sTsss5[13] [10]1CB015[9]00140101[#s123|NBT5][13]
Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2
ALARM
Account Number 123
Reporting Digit 45
14.
OPENING
123
B5
15.
CLOSING
123
C5
16.
CANCEL
123
D5
17.
RESTORE
123
E5
18.
TROUBLE
123
F5
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]210D16[9]00450102[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING ZN B5 [10]1011sssssss123sOssB5[13] [10]829516[9]00460102[#s123|NOPB5][13] DD/DD TT:TT L01 ACCT 123 CLOSING ZN C5 [10]1011sssssss123sCssC5[13] [10]2F8216[9]00470102[#s123|NCLC5][13] DD/DD TT:TT L01 ACCT 123 CANCEL ZN D5 [10]1011sssssss123s\ssD5[13] [10]EC1316[9]00480102[#s123|NOCD5][13] DD/DD TT:TT L01 ACCT 123 RESTORE ZN E5 [10]1011sssssss123sRssE5[13] [10]2E4F16[9]00490102[#s123|NURE5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE ZN F5 [10]1011sssssss123sTssF5[13] [10]C72516[9]00500102[#s123|NBTF5][13]
Bosch Security Systems | 1/05 | 4998122703D
145
D6600 | Computer Interface Manual | Appendix E: Pulse Output
Table 96: #
Event
19.
Pulse 3/2
ALARM
Account Number 123
Reporting Digit 45
20.
OPENING
123
B5
21.
CLOSING
123
C5
22.
CANCEL
123
D5
23.
RESTORE
123
E5
24.
TROUBLE
123
F5
Table 97: #
Event
25.
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]446B16[9]00150101[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING B5 [10]1011sssssss123sOssB5[13] [10]17F616[9]00160101[#s123|NOPB5][13] DD/DD TT:TT L01 ACCT 123 CLOSING B5 [10]1011sssssss123sCssC5[13] [10]BAE116[9]00170101[#s123|NCLC5][13] DD/DD TT:TT L01 ACCT 123 CANCEL B5 [10]1011sssssss123s\ssD5[13] [10]797016[9]00180101[#s123|NOCD5][13] DD/DD TT:TT L01 ACCT 123 RESTORE B5 [10]1011sssssss123sRssE5[13] [10]BB2C16[9]00190101[#s123|NURE5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE B5 [10]1011sssssss123sTssF5[13] [10]EA3F16[9]00200101[#s123|NBTF5][13]
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 5 [10]1011ssssss1234sAsss5[13] [10]97CE15[9]00210101[#1234|NBA5][13] DD/DD TT:TT L01 ACCT 1234 OPENING [10]1011ssssss1234sOssss[13] [10]020A14[9]00220101[#1234|NOP][13] DD/DD TT:TT L01 ACCT 1234 CLOSING [10]1011ssssss1234sCssss[13] [10]510314[9]00230101[#1234|NCL][13] DD/DD TT:TT L01 ACCT 1234 CANCEL [10]1011ssssss1234s\ssss[13] [10]908414[9]00240101[#1234|NOC][13] DD/DD TT:TT L01 ACCT 1234 RESTORE [10]1011ssssss1234sRssss[13] [10]976814[9]00250101[#1234|NUR][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE [10]1011ssssss1234sTssss[13] [10]C29B14[9]00260101[#1234|NBT][13]
Pulse 4/1
ALARM
Account Number 1234
Reporting Digit 5
26.
OPENING
1234
B
27.
CLOSING
1234
C
28.
CANCEL
1234
D
29.
RESTORE
1234
E
30.
TROUBLE
1234
F
146
Device/Mode
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix E: Pulse Output . Table 98: #
Event
31.
Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1
ALARM
Account Number 1234
Reporting Digit 45
32.
OPENING
1234
B5
33.
CLOSING
1234
C5
34.
CANCEL
1234
D5
35.
RESTORE
1234
E5
36.
TROUBLE
1234
F5
Table 99: #
Event
37.
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]418416[9]00270101[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING ZN 5 [10]1011ssssss1234sOsss5[13] [10]C5C215[9]00280101[#1234|NOP5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING ZN 5 [10]1011ssssss1234sCsss5[13] [10]C35115[9]00290101[#1234|NCL5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL ZN 5 [10]1011ssssss1234s\sss5[13] [10]3EE515[9]00300101[#1234|NOC5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE ZN 5 [10]1011ssssss1234sRsss5[13] [10]B3E315[9]00310101[#1234|NUR5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN 5 [10]1011ssssss1234sTsss5[13] [10]F6F615[9]00320101[#1234|NBT5][13]
Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2
ALARM
Account Number 1234
Reporting Digit 45
38.
OPENING
1234
B5
39.
CLOSING
1234
C5
40.
CANCEL
1234
D5
41.
RESTORE
1234
E5
42.
TROUBLE
1234
F5
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]599816[9]00510102[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING ZN B5 [10]1011ssssss1234sOssB5[13] [10]FA0016[9]00520102[#1234|NOPB5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING ZN C5 [10]1011ssssss1234sCssC5[13] [10]571716[9]00530102[#1234|NCLC5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL ZN D5 [10]1011ssssss1234s\ssD5[13] [10]F60416[9]00540102[#1234|NOCD5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE ZN E5 [10]1011ssssss1234sRssE5[13] [10]345816[9]00550102[#1234|NURE5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN F5 [10]1011ssssss1234sTssF5[13] [10]FB2C16[9]00560102[#1234|NBTF5][13]
Bosch Security Systems | 1/05 | 4998122703D
147
D6600 | Computer Interface Manual | Appendix E: Pulse Output
Table 100: Pulse 4/2 #
Event ALARM
Account Number 1234
Reporting Digit 45
43.
44.
OPENING
1234
B5
45.
CLOSING
1234
C5
46.
CANCEL
1234
D5
47.
RESTORE
1234
E5
48.
TROUBLE
1234
F5
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]220516[9]00330101[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING B5 [10]1011ssssss1234sOssB5[13] [10]708D16[9]00340101[#1234|NOPB5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING C5 [10]1011ssssss1234sCssC5[13] [10]DD9A16[9]00350101[#1234|NCLC5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL D5 [10]1011ssssss1234s\ssD5[13] [10]4DC816[9]00360101[#1234|NOCD5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE E5 [10]1011ssssss1234sRssE5[13] [10]8F9416[9]00370101[#1234|NURE5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE F5 [10]1011ssssss1234sTssF5[13] [10]132316[9]00380101[#1234|NBTF5][13]
Device/Mode
Displays
Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode:
DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 456 [10]1011ssssss1234sAs456[13] [10]D5C017[9]00390101[#1234|NBA456][13] DD/DD TT:TT L01 ACCT 1234 OPENING B45 [10]1011ssssss1234sOsB45[13] [10]114C17[9]00400101[#1234|NOPB45][13] DD/DD TT:TT L01 ACCT 1234 CLOSING C45 [10]1011ssssss1234sCsC45[13] [10]1FA117[9]00410101[#1234|NCLC45][13] DD/DD TT:TT L01 ACCT 1234 CANCEL D45 [10]1011ssssss1234s\sD45[13] [10]E2B017[9]00420101[#1234|NOCD45][13] DD/DD TT:TT L01 ACCT 1234 RESTORE E45 [10]1011ssssss1234sRsE45[13] [10]DB7217[9]00430101[#1234|NURE45][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE F45 [10]1011ssssss1234sTsF45[13] [10]CC4C17[9]00440101[#1234|NBTF45][13]
Table 101: Pulse 4/3 #
Event ALARM
Account Number 1234
Reporting Digit 456
49.
50.
OPENING
1234
B45
51.
CLOSING
1234
C45
52.
CANCEL
1234
D45
53.
RESTORE
1234
E45
54.
TROUBLE
1234
F45
148
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix F: Format ID (Identified by Message Type) .
Appendix F: Format ID (Identified by Message Type) If Menu Item 2.5.17 equals 1, the following outputs apply. Generic Example
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
9
r
r
l
s
s
s
s
a
a
a
a
C
C
C
C
C
C
C
C
t
Table 102: Generic Byte Description # 1
Title Header Character (h)
Description Optional, check with the computer automation software for compatibility
2
Message Type
9
3-4 5 6-9 10-13 14-21 22
Receiver Number Line/Group Number Spaces Account Number Channels Trailer Character
Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits Channels 1 to 8 Typically, this is HEX 14
Generic Example
SIA Mode Description [#aaaa|CCCCCCCC]
Table 103: Generic SIA Byte Description Title L CRC
Description Standard line feed character Cyclical redundancy check number
Message Type
9
sequence#
The message sequence number, the valid sequence number range is 0001 to 9999 The receiver gateway that sent the message, valid digits are 01 to 99 The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, four digits. Channel 1 to 8
receiver# line# (Line/Group #) account# CCCCCCCC
The heavier outlined row in Table 102 and Table 103 indicate the meaning of the shaded digit in the D6500 Byte Description, SIA Mode Description Generic Examples, and Table 104 on page 150. Table 104 show examples for each format that the receiver supports. If Menu Item 2.5.17 = 1, the following message type follows a specific format ID. If Menu Item 2.5.17 = 0, the output to automation follows the standard message type ID.
Bosch Security Systems | 1/05 | 4998122703D
149
D6600 | Computer Interface Manual | Appendix F: Format ID (Identified by Message Type)
Table 104: Message Examples #
Communication Format
Mode
Message
1.
Acron Super Fast
2.
Ademco Contact-ID
3.
Ademco 4-1 Express
4.
Ademco 4-2 Express
5.
Ademco High Speed/ Scancom
SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500:
[10]146D18900120101[#123|45678912][13] [10]9011sssss12345678912[14] [10]6A721Ca00140101[#7401|18113003003][13] [10]a011s740118113003003[14] [10]1FDC12b00150101[#1234|7][13] [10]b011ssssss1234sAsss7[14] [10]9D2F13c00160101[#1234|55][13] [10]c011ssssss1234sAss55[14] [10]C3651Cf00180101[#1234|5678s9123s4][13] [10]f011ss1234s5678s9123s4[14]
5-8-1
SIA: D6500:
[10]69311Df00190101[#12345|6789s1234s5][13] [10]f011s12345s6789s1234s5[14]
6-8-1
SIA: D6500:
[10]42CD1Ef00200101[#123456|7891s2345s6][13] [10]f011123456s7891s2345s6[14]
SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D500: SIA: D6500: SIA: D6500: SIA: D6500:
[10]0BB619G00480101[#0308|Nid39OP2][13] [10]G011[#0308|Nid39OP2][14] [10]257B1Ce00570101[#0000|&9569688558][13] [10]e011ssssss9569688558[14] [10]BDAE17i00270101[#123ABC|0108][13] [10]i011ssss123ABC0108ss[14] [10]99EA17d00170101[#1234|NBA567][13] [10]d011ssssss1234sAs567[14] [10]02A215t00400101[#1234|NBA5][13] [10]t011ssssss1234sAsss5[14] [10]40EC16u00410101[#1234|NBA56][13] [10]u011ssssss1234sAss56[14] [10]921C15F00470101[#1234|5678][13] [10]F011ssssss12345678ss[14] [10]5FB90EZ00090124[NLT][13] [10]Z010sssssssssssXss51[14] [10]ABFB19I00490101[#MMTST|g090A31][13] [10]I011sssMvMTSTg090A31[14] [10]2D270B[9]00920100[][13] [10]1010sssssssssss@ssss[14] [10]827316p00340101[#s123|NBA12][13] [10]p011sssssss123sAss12[14]
SIA: D6500: SIA: D6500: SIA: D6500:
[10]16A815p00330101[#s706|NBA1][13] [10]p011sssssss706sAsss1[14] [10]C37A16q00350101[#s706|NBA61][13] [10]q011sssssss706sAss61[14] [10]608F15r00360101[#7066|NBA0][13] [10]r011ssssss7066sAsss0[14]
SIA: D6500: SIA: D6500:
[10]5ACC16r00370101[#1234|NBA12][13] [10]r011ssssss1234sAss12[14] [10]8A7F16s00380101[#7066|NBA02][13] [10]s011ssssss7066sAss02[14]
SIA: D6500: SIA: D6500:
[10]185317s00390101[#1234|NBA566][13] [10]s011ssssss1234sAs566[14] [10]8B9C1AA00440101[#1234|Nti1158LF][13] [10]A011ssssss1234s*ssss[14]
SIA: D6500: SIA: D6500:
[10]942B15B00450101[#1481|NUR2][13] [10]B011ssssss1481sRsss2[14] [10]FFF115C00460101[#s2B2|NBA3][13] [10]C011sssssss2B2sAsss3[14]
4-8-1
6.
ADT SIA
7.
Caller ID
8.
CFSK
9.
DSC/Sur-Gard 4-3
10.
DTMF 4-1
11.
DTMF 4-2
12.
FBI Super Fast
13.
Internal Message
14.
ITI
15.
Link Test
16.
Pulse
3-1 3-1E
17.
Pulse 3-2
18.
Pulse
4-1 4-1E
19.
Pulse
4-2 4-2E
20.
Radionics Modem IIIa2 or Modem IId
21.
Radionics Modem II
22.
Radionics BFSK
150
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix F: Format ID (Identified by Message Type) . Table 104: Message Examples (continued) #
Communication Format
Mode
Message
23.
Robofon
24.
Scancom
SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500:
[10]2D3B15j00280101[#123ABC|12][13] [10]j011ssss123ABC12ssss[14] [10]D47C26g00210101[#1234|2222s2222s2222s2222s2][13] [10]g011ss1234s2222s2222s2222s2222s2[14] [10]91FC27g00220101[#12345|2222s2222s2222s2222s2][13] [10]g011s12345s2222s2222s2222s2222s2[14] [10]13EA28g00230101[#123456|2222s2222s2222s2222s2][13] [10]g011123456s2222s2222s2222s2222s2[14] [10]091930h00240101[#1234|2222s2222s2222s2222s2222s2222s2][13] [10]h011ss1234s2222s2222s2222s2222s2222s2222s2[14] [10]D4ED31h00250101[#12345|2222s2222s2222s2222s2222s2222s2][13] [10]h011s12345s2222s2222s2222s2222s2222s2222s2[14] [10]B51132h00260101[#123452|2222s2222s2222s2222s2222s2222s2][13] [10]h011123452s2222s2222s2222s2222s2222s2222s2[14] [10]61F619K00900101[#7080|*#000***][13] [10]K01113*7080*#000***[14] [10]352815k00290101[#123AB|101][13] [10]k011ssssss123ABs1s01[14] [10]787215700110101[#0258|A56s][13] [10]7011ssssss0258sA56ss[14] [10]86E416[9]00500101[#7080|NBA01][13] [10]S011[#7080|NBA01][14] [10]3E6714E01040101[#4444|NOP][13] [10]E011ssssss4444sOssss[13] [10]3E6714E01040101[#4444|NBA13][13] [10]E011ssssss4444sAss08[14] [10]DC7115m00300101[#7654|sA01][13] [10]m011s7654"sA01[14]
SIA: D6500:
[10]8AAC17m00310101[#123456|HA00][13] [10]m011s123456"HA00[14]
SIA: D6500: SIA: D6500:
[10]C2EB26n00320101[#000257|1090000000110000000][13] [10]n011s000257s1s090000000110000000[14] [10]8EFA16v00430101[#1234|NBA98][13] [10]v011ssssss1234sAss98[14]
SIA: D6500: SIA: D6500: SIA: D6500:
[10]802515v00420101[#1234|NBA9][13] [10]v011ssssss1234sAsss9[14] [10]802515V00450101[#55|123456789ABCDEFG][13] [10]V01155123456789ABCDEFG [14] [10]86E416[9]01430101[#1234|6011100*’THISISATEST’12][13] [10]S011[#1234|6011100*’THISISATEST’12][14]
4-16-1 5-16-1 6-16-1
25.
Scancom
4-24-1 5-24-1 6-24-1
26.
Seriee DTMF
27.
Seriee FSK
28.
Sescoa Super Speed
29.
SIA
30.
Silent Knight
FSK 0 FSK80
31.
Silent Knight
FSK1 FSK2
32.
Telim
33.
Varitech FSK 4-1,Varitech FSK 4-2
34.
VONK
35.
X-SIA
VFSK 4-2 VFSK 4-1
Bosch Security Systems | 1/05 | 4998122703D
151
D6600 | Computer Interface Manual | Appendix G: ADT SIA Report Codes
Appendix G: ADT SIA Report Codes Table 105: ADT SIA Report Codes
Description ADT SIA System Event System Reset Reset Memory AC Fail AA AC Restore AH AC Fail 4 hour AT AC Fail 4 hour Restore AJ TELCO Line Trouble LT (Line 1 or Line 2) TELCO Line Trouble LR Restore (Line 1 or Line 2) Low Battery System YT Low Battery Restore YR Change Date Description ADT SIA Expansion Module Interactive Keypad IA Tamper Interactive Keypad IT Trouble – Supervision Interactive Keypad IR Restore Cardreader Alarm DA Cardreader Trouble DT Cardreader Restore DR Point Gateway Tamper EA Alarm Point Gateway Tamper ET – Supervision Point Gateway Restore ER Printer Tamper Alarm PA Printer Trouble – PT Supervision Printer Restore PR Description ADT SIA Downloading DLL Aborted RA Start DLL RB DLL Interrupted RI End DLL Altered RS DLL Comm Fail RT End DLL Not Altered RG
152
Description
ADT SIA
Burglary BA Burg Alarm BA PT Bypass BA Restore BA Trouble BA PT Unbypass
Description
ADT SIA Panic
BA BB BR BT BU
Description Open/Close BA Auto Close BA Auto Close with Bypass – within Group BA Trouble Closing (closed with burg during exit) BA Bypass Closing – within Group BA Closing BA Auto Open BA Irregular Opening BA Opening BA No Close – Sched close time expire BA Exit Fail, exit error (user)
ADT SIA
Description
ADT SIA
CA CB CF
Hold-Up Alarm Hold-Up Point Trouble (sensor trouble) Hold-Up Restore Hold-Up Point Bypass Hold-Up Point Unbypass Hostage Alarm (Duress) Hostage Restore Medical Alarm Medical Restore Description
CG CL OA OI OP OT
HA HT HR HB HU HH HR MA MR ADT SIA
Scheduling BA Change Close Time Change Auto On Level Change Close Time Print Only
EF
Fire Fire Alarm Fire Trouble Fire Restore Fire Alarm Silence Fire Point Bypass Fire Alarm Point Unbypass Supervisory Alarm Supervisory Trouble Supervisory Restore Supervisory Point Bypass Supervisory Unbypass
FA FT FR FB FU SS ST SR SB SU
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix G: ADT SIA Report Codes . Table 105: ADT SIA Report Codes (Continued)
Description Other Supervised Bell Alarm Supervised Bell Trouble Supervised Bell Restore Remote Power Supply Alarm Remote Power Supply Trouble Remote Power Supply Restore Keyswitch Alarm Keyswitch Trouble Keyswitch Restore Janitor Keyswitch Alarm Janitor Keyswitch Trouble Janitor Keyswitch Restore Janitor On Premises (user on premises) Janitor Off Premises (user on premises restore) ADT On Premises ADT Off Premises Tamper Alarm Tamper Restore VVS Bypass VVS Unbypass Keypad Active Audible Walk Test Change Code Change Early Open Change Holiday Change Latest Close (sent to CMC only if Closing sched is altered) Change Open Time, schedule change Change Time, time/date reset
ADT SIA UA UT UR UA UT UR UA UT UR UA UT UR JI JO
SI SO TA TR VB VU AC AT
CL
Description System Test alk Test, walk test mode Bell Test Hold-Up Test Alarm (sent to printer) Hold-Up Test Restore (sent to printer) Start FA Test, fire test End FA Test, fire test restore Start BA Test End BA Test Start Supervision Test End Supervision Test Start Hold-Up Test End Hold-Up Test Long Print Short Print Supervisory Test Print, manual trigger test report Supervisory Test Restore Fire Test Alarm Print, fire test Fire Test Restore Print, fire test restore BA Point Test Print BA Point Test Restore Print Hold-Up Suspicion Print Keypad No Access Untyped Bypass Untyped Unbypass Tamper Bypass Tamper Unbypass BA Diagnostics FA Diagnostics Output Trouble Output Restore Point Trouble Point Alarm, general alarm
Bosch Security Systems | 1/05 | 4998122703D
ADT SIA WT BT
FM FK BN BK SM SK HM HK
ST
ST FA FR BT BT
Description Point Restore, general alarm restore Untyped Diagnostics BA Weak Battery FA Weak Battery HA Weak Battery SA Weak Battery UA Weak Battery
ADT SIA UR
Description
ADT SIA
Access 2 Man 2nd Person Keypad Lockout Cardreader Irregular Access Manual PB Access, remote arm/disarm opening Access Denied Code Known, access denied Access Denied Code Unknown, access denied
UW BL FL HL SL UL
DI MP
DK DD
Description ADT SIA Dialer Test Report Dialer Test Report RP1 Dialer Test Report with RP5 System Trouble
HS NA UB UU TB TU BW FW UT UR UT UA
153
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages
Appendix H: D6600 RB2000 Messages For lines that are grouped, Gxx appears instead of Lxx.
Table 106: D6600 RB2000 Messages #
Event
1.
Mains Power Failure
2.
3.
Device/ Mode SIA Printer SIA Printer
Mains Power Return
4.
SIA Printer SIA Printer
5.
Battery Broken
SIA Printer
6.
RF Y Battery Empty
SIA Printer
7.
RF Y Battery Full
SIA Printer
8.
HTS Battery Empty
SIA Printer
9.
HTS Battery Full
SIA Printer
10.
Sensor Battery
SIA Printer
11.
SIA Printer
12.
Technical Alarm
SIA Printer
13.
Technical Alarm Confirmed
SIA Printer
154
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 32 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 34 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B2 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B4 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 33 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 33 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 37 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 38 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B8 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 41 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C1
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages . Table 106: D6600 RB2000 Messages (continued) #
Event
14.
PRO 100 Transmitter
15.
16.
SIA Printer PRO 100 Pull Cord
17.
18.
PRO 100 Situation Alarm
Pull Switch
Confirmation at Local Unit
Hand Transmitter/Button
29.
SIA Printer SIA Printer
Emergency Button
27.
28.
SIA Printer SIA Printer
25.
26.
SIA Printer SIA Printer
23.
24.
SIA Printer SIA Printer
21.
22.
SIA Printer SIA Printer
19.
20.
Device/ Mode SIA Printer
SIA Printer SIA Printer
External Input X
SIA Printer SIA Printer
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 42 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C2 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 43 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C3 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 44 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C4 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 46 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C6 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 47 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C7 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 48 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C8 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 49 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C9 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 49 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX C9
Bosch Security Systems | 1/05 | 4998122703D
155
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages
Table 106: D6600 RB2000 Messages (continued) #
Event
30.
RF Y - Alarm
31.
32.
SIA Printer Activity Monitor
33.
34.
Device/ Mode SIA Printer
SIA Printer SIA Printer
Fire Alarm
35.
SIA Printer SIA Printer
36.
Fire Alarm from Ext Input X
SIA Printer
37.
Intrusion
SIA Printer
38.
SIA Printer
39.
Intrusion from Ext Input X
SIA Printer
40.
Intrusion from RF X
SIA Printer
41.
External Alarm Button
SIA Printer
42.
43.
SIA Printer Protocol Error
44.
45.
46.
156
SIA Printer SIA Printer
RF Y Error
SIA Printer SIA Printer
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 49 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY C9 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4A [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CA [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4B [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CB [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4B [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4C [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CC [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4D [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CD [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4E [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CE [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 51 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D1
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages . Table 106: D6600 RB2000 Messages (continued) #
Event
47.
RF Y Maintenance
48.
49.
SIA Printer RF Y Start
50.
51.
RF Y Disassembly
RF Y Test OK
RF Y Test NOK
SIA Printer SIA Printer
RF Y Plug
58.
59.
SIA Printer SIA Printer
56.
57.
SIA Printer SIA Printer
54.
55.
SIA Printer SIA Printer
52.
53.
Device/ Mode SIA Printer
SIA Printer SIA Printer
RF Y Test
60.
SIA Printer SIA Printer
61.
Outgoing Call HNZ
SIA Printer
62.
Resetting
SIA Printer
63.
Personal Sign In
SIA Printer
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 52 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D2 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 53 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D3 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 54 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D4 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 55 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D5 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 56 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D6 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 57 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D7 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 58 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D8 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 60 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 61 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx+++ 0E 00 00 00 62
Bosch Security Systems | 1/05 | 4998122703D
157
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages
Table 106: D6600 RB2000 Messages (continued) #
Event
64.
Personal Sign Out
65.
Door Alarm
SIA Printer
66.
Bed Alarm
SIA Printer
67.
Medical Remind
SIA Printer
68.
Message 1
SIA Printer
69.
Message 2
SIA Printer
70.
Message 3
SIA Printer
71.
Sign Out
SIA Printer
72.
73.
SIA Printer Sign In
74.
75.
Device/ Mode SIA Printer
SIA Printer SIA Printer
Service Call
76.
SIA Printer SIA Printer
77.
Repeated Call
SIA Printer
78.
Confirmation Call
SIA Printer
79.
Pager Call Activated
SIA Printer
80.
Full Duplex Communication
SIA Printer
158
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 63 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 64 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 65 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 66 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 67 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 68 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 69 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 71 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 78 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F1 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F8 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 72 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F2 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 73 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F3 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 74 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 75
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages . Table 106: D6600 RB2000 Messages (continued) #
Event
81.
Test Call
82.
83.
SIA Printer RF Jamming
84.
85.
RF Y No Alive
Call for Assistance
SIA Printer SIA Printer
Registration Call
90.
91.
SIA Printer SIA Printer
88.
89.
SIA Printer SIA Printer
86.
87.
Device/ Mode SIA Printer
SIA Printer SIA Printer
Manual Test Call
92.
SIA Printer SIA Printer
93.
Release Code XX XX
SIA Printer
94.
Error Message HNZ2001
SIA Printer
95.
Error Ended HNZ2001
SIA Printer
96.
Status: Mains Power Failure
SIA Printer
97.
Status: Battery Broken
SIA Printer
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 79 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F9 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7A [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FA [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 7B [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY FB [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7C [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FC [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7D [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FD [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7E [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FE [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 XX XX FF [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX 42 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX C2 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 32 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 33
Bosch Security Systems | 1/05 | 4998122703D
159
D6600 | Computer Interface Manual | Appendix H: D6600 RB2000 Messages
Table 106: D6600 RB2000 Messages (continued) #
Event
98.
Status: Battery Empty
99.
Status: Signed Out
100. Remote Programming Request
160
Device/ Mode SIA Printer SIA Printer SIA Printer
Display [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 37 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 71 [] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 10 00 xx yy 70
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages .
Appendix I: D6600 SafeCom Messages For lines that are grouped, Gxx appears instead of Lxx. In D6500 Mode, the line number or group number sent to the computer is only one digit. Refer to Table 107. Figure 23: SafeCom message characters
2 1
4 3
5
6
7
hprr100000100t 1 - Header 2 - SafeCom
3 - D6600 receiver number (01 to 99) 4 - Line card number or virtual line
5 - Account or virtual account 6 - SafeCom signal 7 - Trailer
If Virtual Line is 00, it is disabled. The D6600 reports the actual D6600 line card number. Table 107: D6600 Virtual Line Conversion Table Line# 01 02 03 04 05 06 07 08 09
Converted to 1 2 3 4 5 6 7 8 9
Line# 0A 0B 0C 0D OE 0F 10 11 12
Converted to A B C D E F G H I
Line # 13 14 15 16 17 18 19 1A 1B
Converted to J K L M N O P Q R
Line # 1C 1D 1E 1F 20 21 22 23 FF
Converted to S T U V W X Y Y Y
Any group greater than or equal to 22 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified.
Bosch Security Systems | 1/05 | 4998122703D
161
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
Table 108: D6600 SafeCom Messages - Line Card or Account Signals
#
Event
Device/ Mode
Display
1.
System Startup
6500/SIA
1
2
Printer 2.
3.
4.
5.
Radio Restart
Battery Trouble
Battery Restoral
Aux. Fault
6500/SIA
hprrl0aaa0100t [#0aaa|0100]
Printer2
dd/dd tt:tt Sxx aaa>restart 1
6500/SIA
hprrl0aaa0103t [#0aaa|0103]
Printer2
dd/dd tt:tt Sxx aaa>BATTERY TROUBLE 1
6500/SIA
hprrl0aaa0104t [#0aaa|0104]
Printer2
dd/dd tt:tt Sxx aaa battery restore
6500/SIA1
hprrl0aaa0103t [#0aaa|0103]
2
7.
Aux. Restoral
AC Trouble
6500/SIA
hprrl0aaa0104t [#0aaa|0104]
Printer2
dd/dd tt:tt Sxx aaa aux restore 1
6500/SIA 2
9.
10.
11.
12.
AC Restoral
External Power Fail
External Power Restoral
Remote Com Restore
RF Trouble
Only valid for DP1000, PID-FE10
dd/dd tt:tt Sxx aaa>AUX FAULT 1
Printer 8.
hprrl00000100t [#0000|0100] dd/dd tt:tt Sxx SYSTEM STARTUP
1
Printer 6.
Notes on Auto Output
Only valid for DP1000, PID-FE10
hprrl0aaa0105t [#0aaa|0105] dd/dd tt:tt Sxx aaa>AC TROUBLE
1
6500/SIA
hprrl0aaa0106t [#0aaa|0106]
Printer2
dd/dd tt:tt Sxx aaa ac restore
6500/SIA1
hprrl0aaa0105t [#0aaa|0105]
Printer2
dd/dd tt:tt Sxx aaa>POWER TROUBLE
6500/SIA1
hprrl0aaa0106t [#0aaa|0106]
Printer2
dd/dd tt:tt Sxx aaa power restore 1
6500/SIA
hprrl0aaa0110t [#0aaa|0110]
Printer2
dd/dd tt:tt Sxx aaa>REMOTE COM RESTORE
6500/SIA1
hprrl0aaa0111t [#0aaa|0111]
Printer2
dd/dd tt:tt Sxx aaa>RF TROUBLE
SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 This indicates that the radio could not report a previous message (until just now).
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168
162
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages . Table 108: D6600 SafeCom Messages - Line Card or Account Signals (continued)
#
Event
Device/ Mode
Display
13.
RF Restore
6500/SIA1
hprrl0aaa0112t [#0aaa|0112]
Printer2
dd/dd tt:tt Sxx aaa rf restore
14.
System RF Channel Busy
1
6500/SIA 2
Printer 15.
16.
System RF Channel Clear Channel Busy
Channel Clear
6500/SIA
hprrl00000112t [#0000|0112]
Printer2
dd/dd tt:tt Sxx CHn channel clear 1
6500/SIA
dd/dd tt:tt Sxx aaa>CHANNEL BUSY
6500/SIA1
hprrl0aaa0122t [#0aaa|0122]
2
Dialer Error
hprrl0aaa0121t [#0aaa|0121]
Printer
Printer 18.
hprrl00000111t [#0000|0111] dd/dd tt:tt Sxx CHn>CHANNEL BUSY
1
2
17.
Notes on Auto Output
dd/dd tt:tt Sxx aaa channel clear 1
6500/SIA
hprrl0aaa022000t [#0aaa|022000]
Printer2
dd/dd tt:tt Sxx aaa>DIALER ERROR e
“e” is error code. See below for details: 0 - unknown error 1 - dialing error 2 - handshake error 3 - noise error 19.
20.
Tamper Fault
Tamper Restore
1
6500/SIA
hprrl0aaa03200301t [#0aaa|03200301]
Printer2
dd/dd tt:tt Sxx aaa>TAMPER FAULT 1
6500/SIA 2
Printer 21.
22.
23.
24.
25.
Phone Line Fail
Phone Line Restore
Aux. Power Fail
Aux. Power Restore
Fire Panic
4 - unexpected disconnect 5 - validation error 6 - priority error
Dialer error is reported to automation in a format similar to 3-1 event.
hprrl0aaa03200101t [#0aaa|03200101] dd/dd tt:tt Sxx aaa tamper restore
1
6500/SIA
hprrl0aaa03200301t [#0aaa|03200301]
Printer2
dd/dd tt:tt Sxx aaa>TELCO TROUBLE
6500/SIA1
hprrl0aaa03200101t [#0aaa|03200101]
Printer2
dd/dd tt:tt Sxx aaa telco restore 1
6500/SIA
hprrl0aaa03200301t [#0aaa|03200301]
Printer2
dd/dd tt:tt Sxx aaa>AUX POWER TROUBLE 1
6500/SIA
hprrl0aaa03200101t [#0aaa|03200101]
Printer2
dd/dd tt:tt Sxx aaa aux power restore 1
6500/SIA
hprrl0aaa03200302t [#0aaa|03200302]
Printer2
dd/dd tt:tt Sxx aaa>FIRE PANIC
Only valid for SC2104 Only valid for SC2104 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168
Bosch Security Systems | 1/05 | 4998122703D
163
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
Table 108: D6600 SafeCom Messages - Line Card or Account Signals (continued)
#
Event
Device/ Mode
26.
Burglary Panic
6500/SIA
1
2
27.
28.
29.
30.
Silent/Medical Panic
Operator Evacuation Bell Input Normal
Input Open
Input Bypass
hprrl0aaa03200304t [#0aaa|03200304]
Printer2
dd/dd tt:tt Sxx aaa>SILENT/MEDICAL PANIC 1
6500/SIA
hprrl0aaa03200305t [#0aaa|03200305]
Printer2
dd/dd tt:tt Sxx aaa>OPERATOR EVACUATION 1
6500/SIA
hprrl0aaa0320011it [#0aaa|0320011i]
Printer2
dd/dd tt:tt Sxx aaa normal: input i 1
6500/SIA
6500/SIA
34.
Zone Restore
dd/dd tt:tt Sxx aaa>SHORTED: input i hprrl0aaa0320041it [#0aaa|0320041i] dd/dd tt:tt Sxx aaa bypass: input i 1
6500/SIA
hprrl0aaa0320051it [#0aaa|0320051i]
Printer2
dd/dd tt:tt Sxx aaa unbypass: input i 1
6500/SIA 2
36.
37.
38.
39.
Zone Trouble
Fire Alarm
Silent Alarm
Burglary Alarm
Zone Bypass
hprrl0aaa0320031it [#0aaa|0320031i]
6500/SIA1
Printer 35.
Only valid for SC5000
hprrl0aaa0320021it [#0aaa|0320021i]
Printer
2
Input Unbypass
Only valid for SC5000
dd/dd tt:tt Sxx aaa>OPENED: input i 1
Printer 33.
Only valid for SC5000
dd/dd tt:tt Sxx aaa>BURGLARY PANIC
2
32.
hprrl0aaa03200303t [#0aaa|03200303]
6500/SIA1
2
Input Short
Notes on Auto Output
Printer
Printer 31.
Display
hprrl0aaa0320011zt [#0aaa|0320011z]
Only valid for SC5000
dd/dd tt:tt Sxx aaa restore: zone z 1
6500/SIA
hprrl0aaa0320021zt [#0aaa|0320021z]
Printer2
dd/dd tt:tt Sxx aaa>TROUBLE: zone z
6500/SIA1
hprrl0aaa0320031zt [#0aaa|0320031z]
Printer2
dd/dd tt:tt Sxx aaa>FIRE: zone z
6500/SIA1
hprrl0aaa0320031zt [#0aaa|0320031z]
Printer2
dd/dd tt:tt Sxx aaa>SILENT: zone z
6500/SIA1
hprrl0aaa0320031zt [#0aaa|0320031z]
Printer2
dd/dd tt:tt Sxx aaa>BURGLARY: zone z
6500/SIA1
hprrl0aaa0320041zt [#0aaa|0320041z]
Printer2
dd/dd tt:tt Sxx aaa BYPASS: zone z
Only valid for SC5000 Only valid for SC5000, depending on the zone type Only valid for SC5000, depending on the zone type Only valid for SC5000, depending on the zone type Only valid for SC5000
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168
164
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages . Table 108: D6600 SafeCom Messages - Line Card or Account Signals (continued)
#
Event
Device/ Mode
40.
Zone Unbypass
6500/SIA
1
2
41.
42.
Operator Armed
User Armed
44.
45.
User Disarmed
User Duress
hprrl0aaa03200600t [#0aaa|03200600]
Printer2
dd/dd tt:tt Sxx aaa OPERATOR ARMED 1
hprrl0aaa0320060ut [#0aaa|0320060u]
6500/SIA
47.
User Cancel
Only valid for SC5000 Only valid for SC5000
dd/dd tt:tt Sxx aaa ARMED: user u 1
6500/SIA
hprrl0aaa03200700t [#0aaa|03200700]
Printer2
dd/dd tt:tt Sxx aaa>OPERATOR DISARMED 1
6500/SIA
hprrl0aaa0320070ut [#0aaa|0320070u]
Printer2
dd/dd tt:tt Sxx aaa>DISARMED: user u 1
hprrl0aaa0320080ut [#0aaa|0320080u]
6500/SIA 2
Operator Cancel
Only valid for SC5000
dd/dd tt:tt Sxx aaa unbypass: zone z
Printer 46.
hprrl0aaa0320051zt [#0aaa|0320051z]
6500/SIA1
2
Operator Disarmed
Notes on Auto Output
Printer
Printer 43.
Display
Only valid for SC5000 Only valid for SC5000 Only valid for SC5000
dd/dd tt:tt Sxx aaa>DURESS: user u 1
6500/SIA
hprrl0aaa03200900t [#0aaa|03200900]
Printer2
dd/dd tt:tt Sxx aaa OPERATOR CANCEL 1
hprrl0aaa0320090ut [#0aaa|0320090u]
6500/SIA 2
Printer
Only valid for SC5000 Only valid for SC5000
dd/dd tt:tt Sxx aaa CANCEL: user u
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168 Table 109: D6600 SafeCom Messages - Intercepted Control Panel Signals
#
Event
Device/ Mode
Display
48.
3-1 Unexpanded
6500/SIA1
hprrlaaaa0220e0t [#aaaa|0220e0]
Printer2
dd/dd tt:tt Sxx aaa>(aaaa) e XXXXXXXX
49.
50.
51.
3-1 Expanded, 4-2, BFSK, or Ademco 42 Express FBI SuperFast
Ademco 4-9 High Speed
1
6500/SIA
hprrlaaaa0220ezt [#aaaa|0220ez]
Printer2
dd/dd tt:tt Sxx aaa>(aaaa) ez XXXXXXXX 1
6500/SIA
hprrlaaaa0321ezzet [#aaaa|0321ezze]
Printer2
dd/dd tt:tt Sxx aaa>(aaaa) ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX
6500/SIA1
hprrlaaaa0620eeeeeeeet0t [#aaaa|0620eeeeeeeet0]
2
Printer
Notes on Auto Output
dd/dd tt:tt Sxx aaa>(aaaa) eeee eeee t
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168
Bosch Security Systems | 1/05 | 4998122703D
165
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
Table 109: D6600 SafeCom Messages - Intercepted Control Panel Signals (continued) #
Event
52.
Ademco Contact ID
Device/ Mode 1 6500/SIA Printer2
53.
54.
1
SIA DCS
6500/SIA
Modem II - PID 0x50
Printer2 1 6500/SIA Printer2
55.
56.
57.
58.
59.
Modem II - PID 0x72, Unexpanded, without Status Report
6500/SIA1
Modem II - PID 0x72, Unexpanded, with Status Report
6500/SIA1
Modem II - PID 0x72, Expanded, without Status Report
6500/SIA
Modem II - PID 0x72, Expanded, with Status Report
6500/SIA1
Modem II - PID 0xBB
6500/SIA1, 3
Printer2
2
Printer
1
Printer2
Printer2
2
Printer 60.
Modem IIe/IIIa2
6500/SIA1, 3 Printer2
61.
Modem IIe/IIIa2 with 4-Digit Zone
6500/SIA1, 3 2
Printer
Display
Notes on Auto Output
hprrlaaaa072018qeeeggccc0t [#aaaa|072018qeeeggccc0] dd/dd tt:tt Sxx aaa>(aaaa) qeee gg czzz >>>>>>>>>>>>>>> aaa>qeeeTTTTTTTTXXXXXXXX hprrlaaaa0f20ffeeeezzzzzz0000000000000000t [#aaaa|0f20ffeeeezzzzzz0000000000000000] dd/dd tt:tt Sxx aaa>(aaaa) feezzz hprrlaaaa03231ezzt [#aaaa|03231ezz] dd/dd tt:tt Sxx aaa>(aaaa) ezz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ez00t [#aaaa|0322ez00] dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ez00t [#aaaa|0322ez00] dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX hprrlaaaa0322ezzzt [#aaaa|0322ezxx] dd/dd tt:tt Sxx aaa>(aaaa) e zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ezzzt [#aaaa|0322ezzz] dd/dd tt:tt Sxx aaa>(aaaa) e zxx >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX hprrlaaaa0621aaeezzz000t [#aaaa|0621aaeezzz000] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0621aaeezzz000t [#aaaa|0621aaeezzz000] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0622aaeezzzz00t [#aaaa|0622aaeezzzz00] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzzz >>>>>>>>>>>>>>> aaa>XXXXXXXX
1 - Refer to Table 110: Explanation of Automation Output Items (within Message Body only) on page 167 2 - Refer to Table 111: Explanation of Printer Output Items on page 168 3 - Refer to Table 112: Supported Event Codes on page 169
166
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages . Table 110: Explanation of Automation Output Items (within Message Body only) Character aaa i z u aaaa e ee eee eeee eeeeeeee t z zz zzz zzzz zzzzzz gg ff aa q ccc
Meaning Radio account number (in hex), range: 001 to 9C4 Input number, range: 1 to 8 Zone number, range: 1 to 8 User number, range: 1 to 8 Control panel account number Event code Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only) Type code
Zone (or contact) code
Group number Function code Area code Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only) Hex contact or user code
Bosch Security Systems | 1/05 | 4998122703D
167
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
Table 111: Explanation of Printer Output Items Character dd/dd tt:tt S xx n aaa > e i z u (aaaa) e ee eee eeee eeee t z zz zzz gg f aa XXXXXXXX TTTTTTTT q
168
Meaning Month and day (MM/DD) Time of message receipt (HH:MM) SafeCom Line card number, range: 01 to 08 Radio channel number, range: 1 to 8 Radio account number (in hex), range: 001 to 9C4 If exists, the signal is in high priority Error code (for dialer error signals only), range: 0 to 6 Input number, range: 1 to 8 Zone number, range: 1 to 8 User number, range: 1 to 8 Control panel account number Event code Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only) Type code Zone (or contact) code Group number Function code Area code Translation text embedded (only when valid digital XLAT is selected for the radio account) Event type can be NEW, RESTORE, or PRIOR (Ademco Contact ID only) Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only)
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages . Modem IIe Format DD/MM HH:MM:SS NNN > (DDDD) AA EE ZZZ Modem IIe messages are reported as AA EE ZZZ where AA is the area code, EE is the event code from Table 112, and ZZZ is the zone or user code. For example: 01 EF 009 = area 1, alarm zone 9. Table 112: Supported Event Codes Code FE FD FC FB FA F9 F8 F7 F6 F5 F4 F3 F2 F1 F0 EF EE ED EC EB EA E9 E8 E7 E6 E5 E4 E3 E2 E1 E0 DF DE DD DC DB DA D9 D8 D7 D6 D5
Meaning Listen in Fail to call RAM Access granted Duress user ZZZ User ZZZ alarm 7 User ZZZ alarm 9 Point ZZZ bypass Point ZZZ forced bypass Status = alarm ZZZ Status = trouble ZZZ Fire alarm ZZZ Fire trouble ZZZ Missing fire ZZZ Fire restore ZZZ Fire trouble restore ZZZ Alarm ZZZ Trouble ZZZ Restore ZZZ Missing alarm ZZZ Missing trouble ZZZ Point ZZZ open Point ZZZ close Extra point ZZZ Point bus trouble All points tested Restoral from alarm Fire cancel User code added Service start Service end Sensor ZZZ reset Relay ZZZ set Relay ZZZ reset Panel was forced armed Cerate status report Fire walk start by user ZZZ Fire walk end Walk test start by user ZZZ Walk test end Fail to open Fail to close Area watch by user ZZZ
Bosch Security Systems | 1/05 | 4998122703D
Code D4 D3 D2 D1 D0 CF CE CD CC CB CA C9 C8 C7 C6 C5 C4 C3 C2 C1 C0 BF BE BD BC BB BA B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 AF AE AD AC AB
Meaning Walk test point Extend close time by user ZZZ Cancel by user ZZZ Status = open Open by user ZZZ Force close by user ZZZ Status = closed Close by user ZZZ Test report Log at threshold Log overflow Parameter change User code tamper by user ZZZ User code for user ZZZ added or changed Sked ZZZ execute Sked ZZZ changed Date changed by user ZZZ Time changed by user ZZZ User level set by user ZZZ Valid programmer access by SDI device ZZZ Invalid programmer access by SDI device ZZZ Valid RAM access on phone ZZZ Invalid RAM access on phone ZZZ Comm fail phone ZZZ Comm restore phone ZZZ Phone line ZZZ fail Phone line ZZZ restore SDI device ZZZ trouble SDI device ZZZ restore Panel AC fail Panel AC restore Panel battery missing Panel battery low Panel battery restore Panel watchdog activated Supervision (non-fire) ZZZ Remote reset ROM checksum failure Memory failure Reboot Parameter checksum failure Force perimeter instant by user ZZZ
169
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
Table 112: Supported Event Codes Code AA A9 A8 A7 A6 A5 A4 A2 A1 A0 9F 9A 99 98 95 94 92 91 90 8F 8E 8D 8C 8B 8A 89 88 87 86 85 84 83 82 81 7F 7E 7D 7C
170
Meaning Force perimeter delay by user ZZZ Status = perimeter instant Status = perimeter delayed Perimeter instant by user ZZZ Perimeter delayed by user ZZZ Passcode for user ZZZ deleted Point bus restore Transmitter point ZZZ battery low Transmitter point ZZZ battery restore Transmitter point ZZZ tamper restore RF receiver trouble by SDI device ZZZ Extra RF point ZZZ RF receiver restore by SDI device ZZZ RF interference by SDI device ZZZ Transmitter point ZZZ tamper alarm Transmitter point ZZZ tamper trouble Equipment restoral by SDI device ZZZ Card assigned by user ZZZ Card deleted by user ZZZ Door cycled point ZZZ Door unlocked point ZZZ Door locked point ZZZ No entry point ZZZ Door left open point ZZZ Door request point ZZZ Network failure path ZZZ Network restoral path ZZZ Network condition path ZZZ Equipment fail by SDI device ZZZ Status supervision point ZZZ Fire Supervision Restoral point ZZZ Fire supervision point ZZZ Fire Supervision Trouble point ZZZ Fire Supervision Trouble Restoral point ZZZ Status fire supervision point ZZZ Extra account path ZZZ Low signal strength path ZZZ RF receiver tamper by SDI device ZZZ
Code 7B 7A 79 78 77 76 75 74 73 72 71 70 6F 6E 6D 6C 6B 6A 69 68 5F 5E 5D 5C 5B 5A 59 58 56 55 54 53 52 51 50 4F 4E
Meaning RF receiver tamper restoral by SDI device ZZZ Status fire alarm point ZZZ Status fire trouble point ZZZ RF interference restoral by SDI device ZZZ Status RF trans low battery point ZZZ Status RF trans tamper alarm point ZZZ Status RF trans tamper trouble point ZZZ Sensor Trouble point ZZZ Sensor Trouble Restoral point ZZZ Status fire missing point ZZZ Status missing alarm point ZZZ Status missing trouble point ZZZ Status door forced point ZZZ Door locked point ZZZ Missing fire supervision point ZZZ Missing supervision point ZZZ Status missing fire supervision point ZZZ Status missing supervision point ZZZ Status door left open point ZZZ Failed to execute point ZZZ Analog service point ZZZ Analog restoral point ZZZ Status analog service point ZZZ Test Failed path ZZZ External device ZZZ Custom Function ZZZ Executed Low Temperature point ZZZ Low Temperature Restoral point ZZZ Unverified Event point ZZZ Printer Status by SDI device ZZZ Abort by user ZZZ Service Request Output ZZZ State Output ZZZ State Restoral Bypass Restoral point ZZZ Alarm Silenced point ZZZ Alarm-Panel Substitution path ZZZ
Bosch Security Systems | 1/05 | 4998122703D
D6600 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages .
Bosch Security Systems | 1/05 | 4998122703D
171
Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189
© 2005 Bosch Security Systems 4998122703D