R Value Calculation Method: Heat loss equation for less than or equal to 30% of total wall area - non-solid construction walls WALL TYPE KEY: Maximu...
Author: Neal Peters
10 downloads 2 Views 533KB Size
R Value Calculation Method: Heat loss equation for less than or equal to 30% of total wall area - non-solid construction walls

WALL TYPE KEY:

Maximum A roof + A 70% of total wall area + A floor + A 30% of total wall area HL reference = 2.9 1.9 1.3 0.26

James Hardie Axon Panel

HL reference =

101.35 + 2.9

James Hardie Linea Weatherborad

FIRE CODE COMPLIANCE: Fire code compliance with NZBC sections C1/AS1, C2/AS1 C3/AS1 & C4/AS1. Purpose group SH in accordance with Table 2.1 Pg 43

75.10 + 101.35 + 32.18 1.9 1.3 0.26

HL reference = 34.95 + 39.52 + 77.96 + 123.78 = 276.22 Calcs provided based on R values supplied in this dwelling;

W11 1200x1600 L 190x90

HL proposed = 32.69 + 44.81 + 77.96 + 85.15 = 240.62 Heat loss value is LESS than the maximum heat loss value based on up to 30% glazing area.

fridge N.i.C

Therefore; COMPLIES

dw space under

WC

tub wm N.i.C LAUN.

KITCHEN

-Asht. 14

D/W

sink

All dimensions are CRITICAL to ensure neat and exact fitting of components/fixtures. Most important are Baths, Showers, Vanities and the like. Due to manufacturing processes these can vary in dimension + or - 5mm. Confirm ALL dimensions prior to placing Gib Board or before permanently fixing any items.

900 vanity

W4 600x1200 L 140x90

BED 3

900sq acrylic shower

linen

66

W12 1200x2400 L 190x90

2/610 sliders

KEY WALL FRAMING:

HALL

EXTERIOR WALLS Allow 90x45 MSG8 H1.2 KD studs @ 450mm ctrs with 2 rows of nogs.

46 0 66

860

71

0

860

0

LIVING

Note: - All joinery to have double glazing. FINDINGS: Insulation R values for dwelling provided: Roof = R3.2 ceiling insulation Wall = R2.2 wall insulation Floor = R1.3 floor insulation

wr

W3 600x1200 L 140x90

BED 2

BED 1

Ensure 'cabinatery and other components' backing nogs are placed prior to placing any wall linings. N.I.C. = Not in Contract.

860

71 WH

BATH.

710

1 ELEVATION KEY

GENERAL NOTES:

0

Glazing Area calculation: Wall Area = 107.28m² Glazing Area = 23.04 Calc. 23.04 / 107.28 x 100 = 21.47% Therfore Less than 30%

W5 1200x1800 L 190x90

2

4

Proposed dwelling compliant with C1/AS1 Detached Dwelling: Paragraphs 1.3.3 & 1.3.4 - Pg 36

1675x760 bath

pantry Hob, u/b oven & rangehood

W6 800x800 obscure safety glass L 90x90

710

101.35 + 85.14 + 101.35 + 22.14 3.1 1.9 1.3 0.26

0

INTERIOR WALLS; Load Bearing Walls - Allow 90x45 MSG8 UT KD studs @ 450mm ctrs with 2 rows of nogs. Non Load Bearing Walls - Allow 90x45 MSG8 UT KD studs @ 600mm ctrs with 2 rows of nogs. 90x45mm timber wall framing

wr

71

0

HL proposed =

D2 2000x880 trim 2015x895 Obsc. with Vision Rail W7 800x600 W10 W9 W8 L 90x90 obscure 900x300 900x300 800x500 L 90x90 L 90x90 L 90x90 L 90x90

3

Construction R values adjusted from the above values provided for the dwelling: Roof = R3.1 (Pitched profile steel using 90mm bottom chord trusses). Wall = R1.9 (Axon Panel & Bevelback weatherboard with 90mm frame). Floor = R1.3 (Enclosed timber subfloor 100mm max. sag sisalation foil) (Area/Perimeter ratio of 2.27) Construction values obtained from BRANZ House Insulation Guide.

D1 2000x2800 unit 2200 Slider + 600 Sidelight and Vision Rail L 290x90

W1 1200x1800 L 190x90

Allow 1 row of tiles (min. 150mm high) as bath splashback to walls around bath. Allow to rebate studs for recessing of bath. Allow 10mm Gib Aqualine on ceiling and walls for all bathrooms & laundry

W2 1200x1800 L 190x90

INSULATION: Allow wall insulation of R2.2 Allow ceiling insulation of R3.2

WET AREAS BATH / KITCHEN / WC / LDY (floor finishes) (NOTE: Non-slip vinyl to achieve a minimum slip resistance coefficient of 0.25 - 0.50) Non-slip vinyl lining over sealed floor. Waterproof seal vinyl to edge of painted skirting contractor to comply with NZBC : E3/AS1 internal moisture.

Lintels as shown from NZS:3604 A2 or similar approved system.

THE MATSON 102

BATH / LDY (Wall & ceiling finishes) 1/Coat GIB sealer with 2/coats GIB Aquaseal paint.

-alteredFloor Area = 101.35m² o/frame

All documentation prepared in accordance with NZS:3604 (Amendment No.2 May 2006)

*All timber stress grading to be a minimum MSG8 or VSG8 unless otherwise noted.

All dimensions & underground service locations to be checked prior to commencement of all works. DO NOT scale off drawings. Cross reference all drawings, confirm site levels, floor heights & restrictions prior to earthworks. If any descrepancies occur, contact Highmark Homes immediatley before commencing works or ordering. COPYRIGHT; These drawings remain the property of HIGHMARK HOMES ltd and are provided for use as described above and may not be used or re-produced in whole or part without written permission. Producer statements issued by all suppliers & tradesmen where applicable. Any site/construction works are not to commence until building permit becomes unconditional.

NEW HOME FOR:

Charitable Build

Wind:

THE MATSON 102 -alteredwww.highmarkhomes.co.nz

Date:

Very High EQ:

B Corrosion Zone: 1

FLOOR PLAN texts only

02 March 2010 Drawn:

CT

Sheet #

Set of

02

27

Scale:

Job # HM-1105

1 : 100

WALL TYPE KEY: James Hardie Linea Weatherborad James Hardie Axon Panel FIRE CODE COMPLIANCE: Fire code compliance with NZBC sections C1/AS1, C2/AS1 C3/AS1 & C4/AS1. Purpose group SH in accordance with Table 2.1 Pg 43

13 620 2 800 90

2 710

3 200 90

3 020

1 590 90

1 590

2 870 90

900

90

3 160

1 700

90

90

3 070

Proposed dwelling compliant with C1/AS1 Detached Dwelling: Paragraphs 1.3.3 & 1.3.4 - Pg 36

90 1 360

90

3 170

8 180

7 630

90 600 90

N.I.C. = Not in Contract. KEY WALL FRAMING: EXTERIOR WALLS Allow 90x45 MSG8 H1.2 KD studs @ 450mm ctrs with 2 rows of nogs.

3 500

BED 2

BED 1

Ensure 'cabinatery and other components' backing nogs are placed prior to placing any wall linings.

INTERIOR WALLS; Load Bearing Walls - Allow 90x45 MSG8 UT KD studs @ 450mm ctrs with 2 rows of nogs. Non Load Bearing Walls - Allow 90x45 MSG8 UT KD studs @ 600mm ctrs with 2 rows of nogs.

90

3 500

LIVING

90 1 360 600

300

90

HALL

90x45mm timber wall framing

600

90

1 000

2 730 900

300

90 90 600

300

2 570

90

BED 3

WH

6 450

7 000

LAUN.

90 90

5 820

90

3 655

5 910

90

600

90

945

90

945

1 ELEVATION KEY

All dimensions are CRITICAL to ensure neat and exact fitting of components/fixtures. Most important are Baths, Showers, Vanities and the like. Due to manufacturing processes these can vary in dimension + or - 5mm. Confirm ALL dimensions prior to placing Gib Board or before permanently fixing any items.

90

1 750

BATH.

2

4

GENERAL NOTES:

550

90

600

550

600

1 050

KITCHEN

2 180 90 90 900 600

300

WC

90

6 630

700

D/W

8 180

300

90

90

90

550

850

3

Allow 1 row of tiles (min. 150mm high) as bath splashback to walls around bath. Allow to rebate studs for recessing of bath. Allow 10mm Gib Aqualine on ceiling and walls for all bathrooms & laundry

90

INSULATION: Allow wall insulation of R2.2 Allow ceiling insulation of R3.2

3 095

7 710

Lintels as shown from NZS:3604 A2 or similar approved system.

13 620

THE MATSON 102 -alteredFloor Area = 101.35m² o/frame All documentation prepared in accordance with NZS:3604 (Amendment No.2 May 2006)

*All timber stress grading to be a minimum MSG8 or VSG8 unless otherwise noted.

All dimensions & underground service locations to be checked prior to commencement of all works. DO NOT scale off drawings. Cross reference all drawings, confirm site levels, floor heights & restrictions prior to earthworks. If any descrepancies occur, contact Highmark Homes immediatley before commencing works or ordering. COPYRIGHT; These drawings remain the property of HIGHMARK HOMES ltd and are provided for use as described above and may not be used or re-produced in whole or part without written permission. Producer statements issued by all suppliers & tradesmen where applicable. Any site/construction works are not to commence until building permit becomes unconditional.

NEW HOME FOR:

Charitable Build

Wind:

THE MATSON 102 -alteredwww.highmarkhomes.co.nz

Date:

Very High EQ:

B Corrosion Zone: 1

FLOOR PLAN dimensions only

02 March 2010 Drawn:

CT

Sheet #

Set of

03

27

Scale:

Job # HM-1105

1 : 100

10.1° pitch Dimond Corrugate 0.4 BMT Colorcote ZR8 Longrun Roofing

JH Linea weatherboad exterior cladding on 20x50 H3.1 cavity battens

NZBC:EXTERNAL MOISTURE Table 2:

Acceptable Solution E2/AS1

Building Envelope Risk Matrix Paragraph 3.1.2, Figure 1 RISK SEVERITY LOW

MEDIUM

HIGH

VERY HIGH

Subtotals for each Risk Factor

Wind zone (per NZS:3604)

0

0

1

2

2

Number of storeys

0

1

2

4

0

Roof/Wall intersection design

0

1

3

5

3

Eaves width

0

1

2

5

5

Envelope complexity

0

1

3

6

1

Deck design

0

2

4

6

0

Risk Factor

S

FFL D1

W1

H3.2 timber steps

ELEVATION 1.

W2

FGL

JH Axon Panel exterior cladding on 20x50 H3.1 cavity battens

powder coated aluminium joinery

NOTE: Risk score shown is the highest risk score for elevations.

JH Linea weatherboard exterior cladding on 20x50 H3.1 cavity battens

D2

S2

D1 = Hinged door with panels of area > 0.5m² = Grade 'A' Safety Glass. D2 = Hinged door with panels of area < 0.5m² = Annealed Glass. D3 = Hinged door with panels of area > 0.5m² = Grade 'A' Safety Glass. D4 = Hinged door with transom = Annealed Glass. > 20

< 1000

D4

D4

S5

S5

> 700

S3

< 1000

> 1000

< 500

S4

4 845

D1

10.1° pitch

approx. building height

> 1000 S1

S1 = Res. side panel of width > 500mm & lower edge < 500mm above highest abutting floor level = Grade 'A' Safety Glass. S2 = Res. side panel of width < 500mm = Annealed Glass. S3 = Res. side panel of width > 1000mm = Grade 'A' Safety Glass. S4 = Res. side panel of width < 1000mm = Annealed Glass. S5 = Res. side panel with transom = Annealed Glass.

S3

11

Note: Cavity battens to exterior claddings

GLAZING SCHEDULE: sg = safety glass.

D3

Total Risk score:

All glazing below 1000mm height in access routes (including stairwells) to be Grade 'A' Safety Glass.

FFL W3

FGL

W4

All glazing to be in accordance with NZS.4223.

ELEVATION 2.

ALL GLAZING TO BE DOUBLE GLAZED

10.1° pitch Dimond Corrugate 0.4 BMT Colorcote ZR8 Longrun Roofing

JH Axon Panel exterior cladding on 20x50 H3.1 cavity battens

JH Linea weatherboard exterior cladding on 20x50 H3.1 cavity battens

1x25mm roof strip brace & tensioner

10.1° pitch

JH Linea weatherboard exterior cladding on 20x50 H3.1 cavity battens

sg sg

FFL W5

ELEVATION 3. All documentation prepared in accordance with NZS:3604 (Amendment No.2 May 2006)

W6

W7

D2

W8

W9

W10

JH Linea weatherboard exterior cladding on 20x50 H3.1 cavity battens

W11

FGL FGL

W12

FFL

powder coated aluminium joinery

ELEVATION 4.

JH Axon Panel exterior cladding on 20x50 H3.1 cavity battens

*All timber stress grading to be a minimum MSG8 or VSG8 unless otherwise noted.

All dimensions & underground service locations to be checked prior to commencement of all works. DO NOT scale off drawings. Cross reference all drawings, confirm site levels, floor heights & restrictions prior to earthworks. If any descrepancies occur, contact Highmark Homes immediatley before commencing works or ordering. COPYRIGHT; These drawings remain the property of HIGHMARK HOMES ltd and are provided for use as described above and may not be used or re-produced in whole or part without written permission. Producer statements issued by all suppliers & tradesmen where applicable. Any site/construction works are not to commence until building permit becomes unconditional.

NEW HOME FOR:

Charitable Build

Wind:

THE MATSON 102 -alteredwww.highmarkhomes.co.nz

Date:

Very High EQ:

B Corrosion Zone: 1

ELEVATIONS

02 March 2010 Drawn:

CT

Sheet #

Set of

04

27

Scale:

Job # HM-1105

1 : 100

GENERAL NOTES: All electrical work & items to comply with; NZBC F7/AS1, AS/NZS 3000, AS/NZS 3008, AS 3786, NZS 6401

METER BOX

Confirm final positioning & fitting allowance with client contract specifications. SD - first alert or similar. Approved smoke alarms are required within 3.0m of any sleeping space door. Smoke alarms must be audible to sleeping occupants on the other side of closed doors. Smoke alarms shall also be located on escape routes within the household.

D/W

distribution board WH

All downlighting to be CA Rated to comply with NZBC: H1/AS1 energy efficiency.

SD

LEGEND: Power Points - All Doubles Lights SD

TV

Light Switches SD

TV

Smoke Detectors- Not in Contract Telephone Jack

TV

Television Jack

ELECTRICAL LAYOUT

All documentation prepared in accordance with NZS:3604 (Amendment No.2 May 2006)

*All timber stress grading to be a minimum MSG8 or VSG8 unless otherwise noted.

All dimensions & underground service locations to be checked prior to commencement of all works. DO NOT scale off drawings. Cross reference all drawings, confirm site levels, floor heights & restrictions prior to earthworks. If any descrepancies occur, contact Highmark Homes immediatley before commencing works or ordering. COPYRIGHT; These drawings remain the property of HIGHMARK HOMES ltd and are provided for use as described above and may not be used or re-produced in whole or part without written permission. Producer statements issued by all suppliers & tradesmen where applicable. Any site/construction works are not to commence until building permit becomes unconditional.

NEW HOME FOR:

Charitable Build

Wind:

THE MATSON 102 -alteredwww.highmarkhomes.co.nz

Date:

Very High EQ:

B Corrosion Zone: 1

ELECTRICAL LAYOUT

02 March 2010 Drawn:

CT

Sheet #

Set of

10

27

Scale:

Job # HM-1105

1 : 100

Note: This drawing is an artistic interpretation of the general appearance of the design. It is not meant to be an exact rendition.

Charity Build.kit

Designed :17/06/2011 Printed: 27/10/2011

Drawing 1