FP HYDRAULIC POWER PACK
Technical Catalogue January
2018 web edition
®
Table of contents
Introduction ...................................................................................................... 2 Endhead configuration .................................................................................... 3 Power pack sections ...................................................................................... 7 Selection code ................................................................................................. 8 Endhead overall dimensions ....................................................................... 11 Cavities dimensions ...................................................................................... 12
SELECTIONS FOR “FPA” POWER PACK ENDHEAD Sect. I - FPA Cavity 1 ..................................................................................... Sect. II - FPA Cavity 2 .................................................................................... Sect. II - FPA Cavity 5 .................................................................................... Sect. II - FPA Cavities 6-7 ............................................................................. Sect. II - FPA Ports A-B .................................................................................
14 15 18 19 20
SELECTIONS FOR “FPC” POWER PACK ENDHEAD Sect. I - FPC Cavity 1 ..................................................................................... Sect. II - FPC Cavity 2 .................................................................................... Sect. II - FPC Cavity 3 .................................................................................... Sect. II - FPC Cavity 4 .................................................................................... Sect. II - FPA Cavity 5 .................................................................................... Sect. II - FPC Cavity 6-7-8-9 .......................................................................... Sect. II - FPC Ports A-B-C .............................................................................
21 22 25 28 18 32 33
SELECTIONS FOR “FPL” POWER PACK ENDHEAD Sect. I - FPL Cavity 1 ...................................................................................... Sect. II - FPL Cavity 2 ..................................................................................... Sect. II - FPL Cavity 3 ..................................................................................... Sect. II - FPL Cavity 4 ..................................................................................... Sect. II - FPL Cavity 7-8 ................................................................................. Sect. II - FPC Ports A-B-C .............................................................................
34 35 38 41 44 33
SELECTIONS FOR “FPE” POWER PACK ENDHEAD Sect. I - FPE Cavity 1 ...................................................................................... Sect. II - FPE Cavity 2 .................................................................................... Sect. II - FPE Cavity 3 .................................................................................... Sect. II - FPE Cavity 9 .................................................................................... Sect. II - FPL Ports A-B-C-D .........................................................................
46 47 49 51 45
SELECTIONS FOR ALL POWER PACK ENDHEADS Sect. III - Pumps ............................................................................................. Sect. IV - Tanks / Sect. V - Tubes kit .......................................................... Sect. VI - DC Motors ...................................................................................... Sect. VI - AC Motors ...................................................................................... Sect. VII - Transmission kit .......................................................................... Sect. VIII - Blocks and CETOP valves ........................................................ Sect. IX - Accessories ..................................................................................
53 55 71 77 83 85 89
Examples ......................................................................................................... 90
© 2018 Dana Brevini S.p.A. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology, logos are trademarks or are registered trademarks of Dana Brevini S.p.A. or other companies Dana in Italy and other countries. The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana Brevini will not be held responsible for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical features of our products, Dana Brevini reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced (in while or in part) without the prior written consent of Dana Brevini. This catalogue supersedes all previous ones. Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating conditions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items..
IE/FP-INTRO/04-2017
1
i
®
Introduction
The validation of the endhead follows a life-test with 250 bar pulsed pressure repeated for 100.000 cycles
i
Operating pressure is controlled by the maximum pressure valve and the type of pump used (in terms of performance) may be determined by the maximum pressure valve. Therefore, it is essential not to change the maximum pressure valve. If neccessary, contact our technical service department Installation 1) The power pack must be mounted using the M10 holes on the endhead. 2) The power pack must not come into contact with sheet metal, protective guards or any parts that may vibrate and transmit noise. 3) The ports on the endhead have been identified by the letters A-B -C. The hydraulic connection must be made with fittings with cylindrical thread and with copper or rubber sealing gaskets (O-rings). 4) After the electrical connections have been made, check the direction of motor rotation by executing short pulses of 1 second each (max.): the motor must turn anti-clockwise, as shown in the figure. The tank must be filled with new mineral-based, ISO 6743/4 fluid: it is important to filter the fluid while filling the tank. The FP series power pack is an easy-to-assemble, compact, electro-hydraulic unit. With its versatility and modularity, it offers many combinations of hydraulic circuits to suit various requirements of plant design. This catalogue has been written to help the user choose the components for the power pack required for the specific application. However, the catalogue cannot foresee all the combinations that may be executed, so in some cases it may be necessary to consult our commercial engineering department.
A OI
M
For applications with very complex circuits, standard modular blocks for Cetop valves and other special blocks can be installed on the power pack, or blocks built to order can be included. A few applications: • Fork lifts • Lifting platforms and beds • Automotive lifts • Cranes for small trucks • Snowplows • Industrial automation (machine tools, food industry, textile industry)
B C
L
82 M10
Symbols used in this catalog: Important data/information Mounting endhead side Ground floor
You can chose from a wide variety of components with the following specifications:
Electrical connection boxes on AC motors
• Gear pumps - Group 05 / 1 - from 0.25 to 9.8 cc. • DC motors, 12/24 V, light-duty service, from 0.35 to 3 Kw • Single and triple-phase motors with power ratings of up to 4 Kw - in a standard version or built to the customer's specifications (with minimum overall dimensions) • Tanks in sheet steel with capacities of up to 25 litres • Tanks in plastic with capacities of up to 10 litres
Poles and/or starting relays on DC motors
A fundamental part of the power pack is the endhead, which is made of die-cast aluminum alloy. The parts and dimensions of this component are shown below.
Standard oil fill plug
Fill plug with breather and level stick Fill plug with breather Standard plug (closed)
Fill plug with breather Operating limits • Intermittent peak pressure: 290 bar (depending on pump type) • Maximum flow rate: 20 l/min • Maximum operating temperature: 80°C (with sheet steel tank) 70°C (with polyethylene tank) 60°C (with polypropylene tank) • Mineral-based hydraulic fluid: ISO 6743-4 (DIN 51524) Minimum viscosity: 12 mm²/s Maximum viscosity: 80 mm²/s Maximum viscosity at start-up: 500 mm²/s • Minimum ambient temperature – 15°C • Maximum ambient temperature 40°C (with peaks of 50°C)
2
Fill plug Fill plug with check valve Fill plug with back check Drain plug with magnet Plug (or level stick) with visual indicator Drain plug
*
Fields to be completed
IE/FP-INTRO/04-2017
®
Endhead configuration Power pack configuration endhead
FPA
5TG
i
5TH
2DA + 2DB + 2DC
2DD
2C
A
B 5
2H A1-B1-C1
2
2FA
2
A2-B2-C2
2Z*
A3-B3-C3
1
1 2TC K1
2TD
7
6
X1
2TE
2TF
7
6
2TK
7
6
Flow control valves
IE/FP-INTRO/04-2017
3
®
Endhead configuration Power pack configuration
2DA
i
3DD
endhead
2DB
FPC
3H
+ 2DC
3FA
2DD
3FB
5 2C
5TG
2H
+
5TH
3A
3
3B +
3TC
2
2FA
9 2Z*
3TD
2TC
3TE
2TD
A
B 5
3TF
C
3TK
2TE
2TF
2
3 A1-B1-C1
2TK
1
4
A2-B2-C2 4DA
8
7
6
9
A3-B3-C3
1
4DB
K1
4DC
8
7
6
9
9TL X1
4DD
4C
4
8
7
6
9
4H
Flow control valves (or plug for cavity 9) 4FA
4Z
4TE
4TF
4TK
4
IE/FP-INTRO/04-2017
®
Endhead configuration Power pack configuration
2DA
3DA
endhead
2DB
2
FPL
i
3DB
2DC
2TC
3DC
2DD
2TD
3DD
2C
2TE
3H
2H
2TF
3FA
2FA
2TK
3FB
3A
3
2Z* 3B
A D B
4DA
3TD
C
3TE 4DB
2
3
4
1
3TF
4DC
4DD
3TK
4C
8
7
4H
4 4B
8
7
8
7
A1-B1-C1
4FA
4Z
A2-B2-C2
A3-B3-C3
1
4TE
Flow control valves
IE/FP-INTRO/04-2017
4TF
K1
4TK
X1
5
®
Endhead configuration Power pack configuration
FPE
i
endhead (for directional control valves)
22D(1A)
2
4
3
1
2
4
S2
22D(1B)
S1
S2
22D(1C)
3
1
2
4
3
1
2
4
S2
22D(1D)
S1
3
2 1
S2
S1
S2
2D(2A)
4
S1
3FA S1
3
1
2
4
A D B
C
3FB
3
+ 2D(2B)
2D(2C)
3
1
2
4
3
1
2
4
3
1
2
4
3
1
3TC
2
3
9
A1-B1-C1
2
2D(2D)
2D(2E)
2
3
1
2D(3A)
2
4
3
1
2D(3B)
2
4
3
1
2D(3C)
2
4
3
1
2
4
3
1
2
4
3
1
2D(3D)
2D(3E)
6
4
1 A2-B2-C2 4
3
2 1
9
9
A3-B3-C3
1 K1
X1
9 Flow control valves
IE/FP-INTRO/04-2017
®
Power pack sections VIII (J-K-W)
VI (M)
i II
VII (T) I
V (G)
III (P)
IV (S)
With its great modularity, the FP series of power packs can create multiple configurations which satisfy requirements in a wide range of applications. To make it easier to choose components, the power pack is subdivided into sections. SECTION I - SERIE, FLANGE TYPE, VALVES ON CAVITY 1 FP Series Powerpacks are based on the Flange features. The Flange is the core of the unit, on the flange are mounted all the valves, the pump, the motor and the reservoir. The FP Flange is available in several Versions (with different tooling options). The Flange Version must be chosen depending on the type of Hydraulic Circuit Layout required. Together with the Flange Version, it is required to select the Valves to be mounted in the Various Cavities. 1 (Main Pressure Relief Valve). SECTION II - VALVES Depending on the Type of Hydraulic Circuit Layout to be realized, it is required to Select the Valves for each of the available Cavities. In order to correctly build up the Ordering Code, it is required to use the following procedure. Peripheral Cavities (it is mandatory to mention all the Cavities in Numeral Order): starting from Cavity 2, mention all the Cavities and the Valves, Plugs or Fittings to be mounted in said Cavity. Internal Cavities: normally connected to Tank (It is not mandatory to mention, but if required it should be done in Numeral Order): starting from Cavity 6, mention all the Internal Cavities where a Valve (usually a Return Line Valve) is mounted, Selecting the Valve Type to be mounted in said Cavity. Outputs, see description in the Table. SECTION III - PUMPS It is mandatory to mention this section, defined by the letter P. Depending on the required features, select the pump from the table provided.
IE/FP-INTRO/04-2017
IX (R)
SECTION IV - TANKS This section is defined by the letter S. Depending on the required features, select the reservoir from the list provided. If no Reservoir is required, and also no Suction / Return Kit is required, please omit this section. If no Reservoir is required, but a Suction / Return Kit is required, please jump to Section V (defined by letter G). SECTION V - TUBES KIT (suction and return, only for tanks on the catalog) This section is defined by the letter G. In order to define this Section, please select the Reservoir Type anyways. SECTION VI - MOTORS This section is defined by the letter M. Depending on the Type of Hydraulic Circuit Layout to be realized, it is required to Select the Motor Type. If no Motor is required, and no Transmission Kit is required, please omit this section. If no Motor is required, but a Transmission Kit is required, please jump to Section VII (defined by letter T). SECTION VII - TRANSMISSION KIT (only for motors on the catalog) This section is defined by the letter T. Select the kit as per Table provided. SECTION VIII - BLOCKS This section it is not mandatory, depending on the Type of auxiliary Block required, definition Letter changes: J, Blocks with CETOP type of interface for Solenoid Valves; K, Bankable Valves Interface – Horizontal (Parallel to Unit Axis); W, Bankable Valves Interface – Vertical (Perpendicular to Unit Axis); SECTION IX - ACCESSORIES his section it is not mandatory, is defined by the letter R Check the available options in the list provided. Accessories must be listed in Alphabetical Order. 7
®
Selection code SECTION I - SERIE, ENDHEAD, VALVES ON CAVITY 1
i
Power pack type Endhead type Thread ports Pressure relief valve - Check valve - Plug Setting type (or plug features) Special setting pressure relief valve (omit if not required) FP * * * * (...)
SECTION II - VALVES Cavity 2 Type Features Optional flow control valve (omit if not required) Cavity 3 Type Features Flow control valve can be combined with plug TC Cavity 4 Type Features Cavity 5 Plug Features Flow control valve can be combined with plug TG Return cavities 6-7-8-9 Optional flow control valve (or plug for cavity 9) Combination plugs for ports (ABC) End section II
2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 * -** -
SECTION III - PUMPS Pump Pump group Performance level Nominal displacement Accessories (omit if not required) End section III P * (*) ** / * -
8
IE/FP-INTRO/04-2017
®
Selection code SECTION IV - TANKS / SECTION V - TUBES KIT
i
Section: S = tank (with tubes kit) ; G = only with tubes kit, without tank; OMIT if without tank and without tubes kit Capacity liters Features (material and construction) Mounting position: H = horizontal; V = vertical Variants 00 = standard, no variant; OMIT if with tubes kit (section “G”) Orientation OMIT if with tubes kit in vertical mounting position (section “G”) End section IV and V * ** * (*) **
/* -
SECTION VI - MOTORS DC motor Voltage Power / Size Version Accessories 0 = whitout accessories; Orientation End section VI M * ** (*) * /* -
OR .. AC motor Phases Poles Size Power range Version Orientation End section VI M *
*
*
* (*) /* -
IE/FP-INTRO/04-2017
9
®
Selection code SECTION VII - TRANSMISSION KIT (only for motors on the catalog)
i
Transmission kit Type End section VII Specify the transmission kit whether you requested the joint and accessories assembly (without motor). T ** -
SECTION VIII - BLOCKS
Blocks Mounting position Accessory Separation line Block type Accessory Pressure relief valve setting on “A” line Pressure relief valve setting on “B” line CETOP valve End section VIII J
* (00) - ** (00) (..) (..) /***/ -
SECTION IX - ACCESSORIES Accessories (optional) First accessory Second accessory
R
10
*
*
IE/FP-INTRO/04-2017
®
Endhead overall dimensions Cavities on endhead:
Ports
B
Ports
C
Ports
D
Ports
1 2 3 4 5 6 7 8 9
Peripheral Peripheral Peripheral Peripheral Peripheral (2) Return Return Return Return
•
•
•
•
•
•
•
•
—
•
•
•
G1/4” (1)
—
—
•
•
3/4” 16 UNF 3/4” 16 UNF 3/4 “16 UNF 3/4” 16 UNF M16x1.5 G3/8” G3/8” G3/8” G3/8”
• • — — • • • — —
• • • • • • • • •
• • • • — — • • —
• • • — — — — — •
i
82
POWER PACK FIXING SIDE 134 101.6
1) blocks interface 2) available only for FPA - FPC endhead 3) the cavity 5 is not accessible with blocks mounted (section IX).
6
7
9 2 101.6
4 HOLES WITH Ø7 (FOR ATTACHING TANKS)
3
PUMP/TANK SIDE
134
G1/4” (1) G3/8” (2) G1/4” (1) G3/8” (2) G1/4” (1) G3/8” (2)
A
There are three types of cavities: - Peripheral cavities, which can be accessed externally - Return cavities, inside of the tank. - Ports
22.5
Thread
2 HOLES M10 (18)
Cavity
The number of cavities tooled identify the endhead type: Endhead type FPA FPC FPL FPE
1
4 8 PORT SIDE
GROOVE FOR TANK SEALING GASKET (O-RING, 3.53x110.72)
A
52
C MOTOR SIDE
118 10°
4 HOLES 1/4-20 UNC (112) WITH CENTER DISTANCE OF 91
Ø 120
20°
Ø32
Ø30
Ø 35
Ø 80
Ø 98.3
Ø 110
15.5
4
14.1
5 (1)
2 - M6 HOLES (10) WITH CENTER DISTANCE OF 101.5
48.5 45
D B
15.4
118
4 HOLES M8 The cavities (1-2-3-4-5) and the ports (A-B-C) are marked on the die-cast endhead. The dimensions on the drawing are the same for all endhead.
IE/FP-INTRO/04-2017
11
®
Cavities dimensions Cavity
Thread
Drawing
Cavity
Thread
Drawing
CD018013
5
Peripheral
M16x1.5
7.2 20.5
17.5
Ø 12.7
12
M16x1.5
Ø 14.5
Peripheral 3/4 16 UNF 3/4-16 UNF
1
Ø 15.8
Ø 26
Ø 16.4
i
24.6 42.5
34
62.5
2
5
Ø 11.5
12 17.5
Ø 12.7
6
Return
G3/8
Peripheral 3/4 16 UNF (FPA-FPC)
3/4-16 UNF
2
Ø 26
CD018009
G3/8
15 18.5
41 66.5
11.5 19.1 33.3 47.6 56
7
Return
G3/8
G3/8
Ø 11.5 Ø 12.7 Ø 14.3
Ø27
Peripheral 3/4 16 UNF (FPE)
3/4-16 UNF
2
Ø15.9
CD018001
23 37
12 17.5
8
Return
G3/8
G3/8
Peripheral 3/4 16 UNF 3/4-16 UNF
3
Ø 12.7
Ø 26
CD018014
21 30
30.5
12
12 17.5 30.5
9
Return
G3/8
G3/8
Peripheral 3/4 16 UNF 3/4-16 UNF
4
Ø 12.7
Ø 26
CD018014
22 27
IE/FP-INTRO/04-2017
®
Endhead choice Endhead type Thread ports FP
*
*
FP A
A
B
C A
5
2
1
7
B
II II
L 5
A
C
D
B
C
2
3
2
3
4
1
4
1
8
6
7
6
8
9
7
E A
*
Endhead type
*
Ports
Peripheral
Return
A
n. 2 (A - B)
n. 3 (1 - 2 - 5)
n. 2 (6 - 7)
C
n. 3 (A - B - C)
n. 5 (1 - 2 - 3 - 4 - 5)
n. 4 (6 - 7 - 8 - 9)
L
n. 4 (A - B - C - D)
n. 4 (1 - 2 - 3 - 4)
n. 2 (7 - 8)
E
n. 4 (A - B - C - D)
n. 3 (1 - 2 - 3)
n. 1 (9)
D
B
C
2
3
1
9
*
Thread ports Ports thread
*
G1/4”
G3/8”
YES
0
YES YES
1
Blocks interface NO
Endhead codes G1/4” G3/8” FPA
78013010.000
78013011.000
FPC
78013014.000
78013015.000
FPL
78013022.000
FPE
78013016.000
IE/FP/00-2016
13
®
Sect. I - FPA Cavity 1 A
Pressure relief valve - Check valve - Plug Setting type (or plug features) Special setting pressure relief valve (omit if not required)
FPA
5
B
2
FPA** * * (...)
I II
1
7 A
B
5
6
A1 B1 C1 A2 B2 C2
2
A3 B3 C3
1
K1
7
6 X1
*
*
*
*
Pressure relief valve with check valve
(...)
Pressure (bar)
STD setting (bar)
(...) Special setting (bar)
50
10 ÷ 60 (5 to 5)
1 A
2
10 ÷ 60
3 1 B
2
> 60 ÷ 180
150
65 ÷ 180 (5 to 5)
3 1 C
2
> 180 ÷ 320
210
190 ÷ 320 (10 to 10)
3
Setting type
Code
Detachable closing
CMPR04S01001
Non removable closing (1)
CMPR04P01001
Handwheel
CMPR04V01001
Detachable closing
CMPR04S02001
Non removable closing (1)
CMPR04P02001
Handwheel
CMPR04V02001
Detachable closing
CMPR04S03001
Non removable closing (1)
CMPR04P03001
Handwheel
CMPR04V03001
Symbol
Drawing
1
2
3
1 = Supplied assembled. Unassembled, see accessories page 89.
*
*
Check valve and plug
*
*
Description
K
1
Check valve - Opening pressure 0.5 bar
CRI0400001
X
1
Plug
R78150100
14
Code
Symbol
Drawing
IE/FPA-1/03-2017
®
Sect. II - FPA Cavity 2 Cavity Type Features Optional flow control valve (omit if not required) FPA** ** (...) 2
.. ** +*
FPA B
A 2DA**
+*
2DB**
+*
2DC**
+*
I II
5
2
1 2DD**
+* 7
2C*
+*
2H*
+*
6
2FA*
2Z*
A
B
5
2TC
2TD
2
G 1/4 2TE
1 2TF
G 1/4 2TK
7
6
G 1/4
Optional flow control valves
IE/FPA-2/03-2017
15
®
Sect. II - FPA Cavity 2 2 DA **
FPA I II
**
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
2 DB **
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEL003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AF
2 DD **
Voltage 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Voltage 48 Vdc
Code (valve + connector)
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Direct operated solenoid valves normally closed, with emergency
**
Description
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
*
Drawing
Piloted solenoid valves normally open, with emergency Description
AE
16
Code (valve + connector)
**
AD
Symbol
Piloted solenoid valves normally closed, with emergency Description
AC
C
Code (valve + connector)
**
2 DC **
2
Piloted solenoid valves normally closed, without emergency
Code (valve + connector)
Lever operated valve
**
Description
Code
A
Without microswitch
CMF04L001
B
With microswitch
CMF04M001
IE/FPA-2/03-2017
®
Sect. II - FPA Cavity 2 2
H
Button operated valves
* **
Description
A
Push-button control
Code
Symbol
Drawing
CPE04P0001
FPA 2
..
2 FA
2
2
Z
T
**
+*
Flow control valves (1)
*
Flow
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
I II Symbol
Drawing
(1) The flow control valves can be installed with solenoid valves, with manual controls and with push-button valves.
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Hand pumps
*
Description
A
Displacement 1 cc
CPM0410001
B
Displacement 2 cc
CPM0420001
*
Plugs and fittings
*
Description
C
Plug 3/4 16 UNF
R78150099
D
Fitting 3/4 16 UNF - G1/4
20001700
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF DIN - G1/4
20018000
IE/FPA-2/03-2017
Code
Code
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
17
®
Sect. II - FPA Cavity 5 Peripheral Plug Features Flow control valve can be combined with plug TC
FPA
FPA** ** (...) 2
.. ** +* 5 T * +*
I II
5TG
5TH
+*
Optional flow control valve A
B
5
A
B
5
2
2 1
7
1
6
7
5
5
18
T
T
*
Plugs
*
Description
G
Plug M16x1,5 (1)
R78150104
H
Long plug M16x1,5
R78150101
G
+*
Flow control valves
(1)
*
Flow
Code
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
Symbol
Symbol
6
Drawing
Drawing
(1) Flow control valves can be combined with plug TG.
IE/FPA-2/03-2017
®
Sect. II - FPA Cavities 6-7 Return cavities FPA** ** (...) 2
.. ** +* 5 T * +* 6 * 7 * Optional flow control valves
Return cavity, omit if not required flow control valves
A
B
FPA I II
5
2
1
A 7
B
5
6
2
1
7*
6*
7 6 Optional flow control valves
6 7
*
Flow control valves for return cavities”6-7”
*
Nominal flow at 120 bar
A
0.7 l/min
VSC06100002
B
1.1 l/min
VSC06120002
C
2.1 l/min
VSC06130002
E
3.2 l/min
VSC06150002
G
4.7 l/min
VSC06190002
K
6.3 l/min
VSC06220002
N
7.5 l/min
VSC06240002
Q
10.0 l/min
VSC06280002
U
13.2 l/min
VSC06330002
V
15.7 l/min
VSC06350002
IE/FPA-2/03-2017
Code
Symbol
Drawing
19
®
Sect. II - FPA Ports A-B Possible combinations plugs on ports End section II
FPA
FPA** ** (...) 2
.. ** +* 5 T * +* 6 * 7 * -** -
I II
A
B
5
A
B
5
2
2 1
7
6
1
7
-**
6
Possible combinations plugs on ports A-B Symbols description
-**
A
B
-00
n
n
-02
n
-03
n
-06
Type Description
Port closed with plug
n
Open port
Thread
Code
G 1/4”
20024000
G 3/8”
Q26630006 (plug with OR) —
Symbol
Drawing
—
—
Combination -00 to use with the standard blocks (page 85)
20
IE/FPA-2/03-2017
®
Sect. I - FPC Cavity 1 A
Pressure relief valve - Check valve - Plug Setting type (or plug features) Special setting pressure relief valve (omit if not required) FPC** * * (...)
B
5
3
4
1
C
6
FPC
9
I II
A2 B2 C2 A3 B3 C3
1
4
7
A1 B1 C1
3
2
C
2
8 A
5
B
K1
8
7
6
9 X1
* *
Pressure relief valve with check valve
(...) *
Pressure (bar)
STD setting (bar)
(...) Special setting (bar)
50
10 ÷ 60 (5 to 5)
1 A
2
10 ÷ 60
3 1 B
2
> 60 ÷ 180
150
65 ÷ 180 (5 to 5)
3 1 C
2
> 180 ÷ 320
210
190 ÷ 320 (10 to 10)
3
Setting type
Code
Detachable closing
CMPR04S01001
Non removable closing (1)
CMPR04P01001
Handwheel
CMPR04V01001
Detachable closing
CMPR04S02001
Non removable closing (1)
CMPR04P02001
Handwheel
CMPR04V02001
Detachable closing
CMPR04S03001
Non removable closing (1)
CMPR04P03001
Handwheel
CMPR04V03001
Symbol
Drawing
1
2
3
1 = Supplied assembled. Unassembled, see accessories page 89.
*
*
Check valve and plug
*
*
Description
K
1
Check valve - Opening pressure 0.5 bar
CRI0400001
X
1
Plug
R78150100
IE/FPC-1/03-2017
Code
Symbol
Drawing
21
®
Sect. II - FPC Cavity 2 Cavity Type Features Optional flow control valve (omit if not required) FPC** ** (...) 2
.. ** +*
B
A
FPC I II
2DA**
+*
2DB**
+*
2DC**
+*
5
C
3
2
1
4 2DD**
+* 8
2C*
+*
2H*
+*
7
6
9
2FA*
2Z*
A
B
5
C
2TC
2TD
2
3
4
1
G 1/4 2TE
2TF
G 1/4 2TK
8
7
6
9
G 1/4
Optional flow control valves
22
IE/FPC-2/03-2017
®
Sect. II - FPC Cavity 2 Piloted solenoid valves normally closed, without emergency
2 DA ** **
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
**
Description
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEL003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
Description
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AE AF
Voltage 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Voltage 48 Vdc
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
FPC I II
Code (valve + connector)
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Direct operated solenoid valve normally closed, with emergency
2 DD **
C
Code (valve + connector)
**
AD
Drawing
Piloted solenoid valves normally open, with emergency
2 DC **
AC
Symbol
Piloted solenoid valves normally closed, with emergency
2 DB **
2
Code (valve + connector)
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
Lever operated valve
* **
Description
A
Without microswitch
CMF04L001
B
With microswitch
CMF04M001
IE/FPC-2/03-2017
Code
23
®
Sect. II - FPC Cavity 2 2
2
H
..
**
Description
A
Push-button control
**
+*
Flow control valves (1)
*
Flow
FPC I II
2 FA
2
2
24
Z
T
Button operated valves
*
Code
Symbol
Drawing
CPE04P000.1
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
Symbol
Drawing
(1) The flow control valves can be installed with solenoid valves, with manual controls and with push-button valves.
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Hand pumps
*
Description
A
Displacement 1 cc
CPM0410001
B
Displacement 2 cc
CPM0420001
*
Plugs and fittings
*
Description
C
Plug 3/4 16 UNF
R78150099
D
Fitting 3/4 16 UNF - G1/4
20001700
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF DIN - G1/4
20018000
Code
Code
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
IE/FPC-2/03-2017
®
Sect. II - FPC Cavity 3 Cavity Type Features Flow control valve can be combined with plug TC FPC** ** (...) 2
.. ** +* 3
.. ** +*
B
A
5
C
FPC
3H*
3
2
3DD*
I II
3FA* 1
4
3FB* 8
7
6
9 3A**
3B*
+*
A
B
5
3TC
3TD
C
G 1/4 3TE
3
2
3TF
G 1/4
1
4
3TK
G 1/4
8
IE/FPC-2/03-2017
7
6
9
Optional flow control valves
25
®
Sect. II - FPC Cavity 3 3 DD **
3
H
Piloted solenoid valves normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
*
Button operated valves
**
Description
A
Push-button control
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Unidirectional flow control valves compensated
*
Description
A
Screw adjustment
CSC04C0000
B
Plastic knob adjustment
CSC04V0000
**
Pressure relief valves
**
Description
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
FPC CPE04P000.1
I II 3 FA
3 FB
3
A
Code
Regolazione (bar)
Code
Min 10 - Max 70
CMP04E1001
Min 80 - Max 140
CMP04E2001
AC
Min 100 - Max 330
CMP04E3001
BA
Min 10 - Max 70
CMP04C1001
Min 80 - Max 140
CMP04C2001
Min 100 - Max 330
CMP04C3001
Min 10 - Max 70
CMP04V1001
Min 80 - Max 140
CMP04V2001
CC
Min 100 - Max 330
CMP04V3001
DA
Min 10 - Max 70
CMP04P1001
Min 80 - Max 140
CMP04P2001
Min 100 - Max 330
CMP04P3001
AA AB
BB
Short screw adjustment
Screw adjustment
BC CA CB
DB DC
26
Code
Plastic knob adjustment
Short screw + sealed cap
IE/FPC-2/03-2017
®
Sect. II - FPC Cavity 3 3
3
3
B
T
T
*
One-way check valves
*
Opening pressure
A
0,7 bar (Standard)
CRU0400002
B
4,5 bar
CRU0404002
C
10 bar
CRU0410002
*
Code
Symbol
Drawing
Symbol
Drawing
Plugs and fittings
*
Description
Code
C
Plug 3/4 16 UNF (1)
R78150099
D
Fitting 3/4 16 UNF - G1/4
20001700
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF - DIN G1/4
20018000
C
+*
Flow control valves (1)
*
Flow
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
IE/FPC-2/03-2017
Symbol
FPC I II
Drawing
(1) I The flow control valves can be installed with the plug TC
27
®
Sect. II - FPC Cavity 4 Cavity Type Features FPC** ** (...) 2
.. ** +* 3
.. ** +* 4
.. **
FPC
4DB**
I II
B
A
4DA**
5
C
3
2
4DC** 4
1
4DD** 8
7
6
9
4C*
4H*
4FA*
A
B
5
C
4Z*
4TE
4TF
G 1/4
2
3
4
1
4TK
G 1/4
28
8
7
6
9
IE/FPC-2/03-2017
®
Sect. II - FPC Cavity 4 4 DA **
Piloted solenoid valves normally closed, without emergency
**
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
4 DB **
Code (valve + connector)
Description
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
Code (valve + connector)
Description
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AD AE AF
4 DD **
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
FPC I II
Piloted solenoid valves normally open, with emergency
**
AC
Drawing
Piloted solenoid valves normally closed, with emergency
**
4 DC **
Symbol
Tensione 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Tensione 48 Vdc
Code (valve + connector)
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Direct operated solenoid valve normally closed, with emergency
**
Description
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
IE/FPC-2/03-2017
Code (valve + connector)
29
®
Sect. II - FPC Cavity 4 4
FPC
4
C
H
I II
4 FA
4
4
30
Z
T
*
Lever operated valve
**
Description
A
Without microswitch
CMF04L0001
B
With microswitch
CMF04M0001
*
Button operated valves
**
Description
A
Push-button control
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Hand pumps
*
Description
A
Displacement 1 cc
CPM0410001
B
Displacement 2 cc
CPM0420001
*
Plugs and fittings
*
Description
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF DIN - G1/4
20018000
Code
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
CPE04P000.1
Code
Code
Code
IE/FPC-2/03-2017
®
Sect. II - FPC Cavity 5 Peripheral Plug Features Flow control valve can be combined with plug TG FPC** ** (...) 2
.. ** +* 3
.. ** +* 4
5TG
.. ** 5 T * +*
5TH
FPC +*
I II
Optional flow control valve A
B
5
C
A
B
2
3
4
1
1
4
8
7
6
9
8
5
T
T
C
3
2
5
5
*
Plugs
*
Description
G
Plug M16x1,5 (1)
R78150104
H
Long plug M16x1,5
R78150101
G
+*
Flow control valves (1)
*
Flow
Code
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
IE/FPC-2/03-2017
Symbol
7
Symbol
6
9
Drawing
Drawing
(1) I The flow control valves can be installed with the plug TG 31
®
Sect. II - FPC Cavity 6-7-8-9 Return cavities FPC** ** (...) 2
.. ** +* 3
.. ** +* 4
.. ** 5 T * +* 6 * 7 * 8 * 9 * Optional flow control valves (or plug on cavity 9)
Return cavity, omit if not required flow control valves or caps
B
A
C
5
3
2
FPC I II
1
4
A 8
8*
7
7*
6
6*
B
5
C
9
9*
9L
2
3
4
1
8 7 6 9 Optional flow control valves or plug on cavity 9
6 7 8 9
9T
32
*
Flow control valves for return cavities ”6-7-8-9”
*
Nominal flow at 120 bar
A
0.7 l/min
VSC06100002
B
1.1 l/min
VSC06120002
C
2.1 l/min
VSC06130002
E
3.2 l/min
VSC06150002
G
4.7 l/min
VSC06190002
K
6.3 l/min
VSC06220002
N
7.5 l/min
VSC06240002
Q
10.0 l/min
VSC06280002
U
13.2 l/min
VSC06330002
V
15.7 l/min
VSC06350002
*
Plugs for return cavity “9”
*
Description
M
Conical plug G3/8
Code
Code
Symbol
Drawing
Symbol
Drawing
Q26620350
IE/FPC-2/03-2017
®
Sect. II - FPC Ports A-B-C Possible combinations plugs on ports End section II FPC** ** (...) 2
.. ** +* 3
.. ** +* 4
.. ** 5 T * +* 6 * 7 * 8 * 9 * -** -
FPC I II A
B
5
C
A
B
C
3
2
4
1
7
8
6
9
2
3
4
1
8
-**
5
7
6
9
Possible combinations plugs on ports A-B-C
-**
A
B
C
-00
n
n
-01
n
n
n
-02
n
n
-03
n
n
-05
n
-06
n
-07
n
-08
Symbols description Type Description
Port closed with plug
n
Open port
Thread
Code
G 1/4”
20024000
G 3/8”
Q26630006 (plug with OR) —
Symbol
Drawing
—
—
Combination -00 to use with the standard blocks (page 85)
IE/FPC-2/03-2017
33
®
Sect. I - FPL Cavity 1 A
Pressure relief valve - Check valve - Plug Setting type (or plug features) Special setting pressure relief valve (omit if not required) FPL** * * (...)
D
2
3
4
1
8 A
B
D
FPL
C
A2 B2 C2
I
A3 B3 C3
1
4
7
A1 B1 C1
3
2
C
B
K1
8
7 X1
* *
Pressure relief valve with check valve
(...) *
Pressure (bar)
STD setting (bar)
(...) Special setting (bar)
50
10 ÷ 60 (5 to 5)
1 A
2
10 ÷ 60
3 1 B
2
> 60 ÷ 180
150
65 ÷ 180 (5 to 5)
3 1 C
2
> 180 ÷ 320
210
190 ÷ 320 (10 to 10)
3
Setting type
Code
Detachable closing
CMPR04S01001
Non removable closing (1)
CMPR04P01001
Handwheel
CMPR04V01001
Detachable closing
CMPR04S02001
Non removable closing (1)
CMPR04P02001
Handwheel
CMPR04V02001
Detachable closing
CMPR04S03001
Non removable closing (1)
CMPR04P03001
Handwheel
CMPR04V03001
Symbol
Drawing
1
2
3
1 = Supplied assembled. Unassembled, see accessories page 89.
*
*
Check valve and plug
*
*
Description
K
1
Check valve - Opening pressure 0.5 bar
CRI0400001
X
1
Plug
R78150100
34
Code
Symbol
Drawing
IE/FPC-1/00-2017
®
Sect. II - FPL Cavity 2 Cavity Type Features
FPL** ** (...) 2
.. **
B
A
D
C
2DA**
2DB**
3
2
2DC** 1
4
FPL
2DD** 8
7
2C*
II
2H*
2FA*
2Z*
A
D
B
C
2TC
2TD
2
3
4
1
G 1/4 2TE
2TF
G 1/4 2TK
8
7
G 1/4
IE/FPC-1/00-2017
35
®
Sect. II - FPL Cavity 2 2 DA ** **
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
2 DB **
FPL
Piloted solenoid valves normally closed, without emergency Code (valve + connector)
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Piloted solenoid valves normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEL003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
II 2 DC ** **
Description
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AC AD AE AF
2 DD **
2
36
C
Piloted solenoid valves normally open, with emergency
Voltage 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Voltage 48 Vdc
Code (valve + connector)
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Direct operated solenoid valve normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
*
Lever operated valve
**
Description
A
Without microswitch
CMF04L001
B
With microswitch
CMF04M001
Code
IE/FPC-1/00-2017
®
Sect. II - FPL Cavity 2 2
H
2 FA
*
Button operated valves
**
Description
A
Push-button control
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
Code
Symbol
Drawing
Symbol
Drawing
CPE04P000.1
Code
FPL 2
2
Z
T
*
Hand pumps
*
Description
A
Displacement 1 cc
CPM0410001
B
Displacement 2 cc
CPM0420001
*
Plugs and fittings
*
Description
C
Plug 3/4 16 UNF
R78150099
D
Fitting 3/4 16 UNF - G1/4
20001700
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF DIN - G1/4
20018000
IE/FPC-1/00-2017
Code
Code
Symbol
Drawing
Symbol
Drawing
II
37
®
Sect. II - FPL Cavity 3 Cavity Type Features
FPL** ** (...) 2
.. ** 3
.. **
B
A
D
C 3DA*
3DB*
3
2
3DC* 1
4
3DD*
FPL
8
7 3H*
II 3FA*
3FB*
A
D
B
3A**
C
3B*
3
2
3TD
1
4
G 1/4 3TE
3TF
8
7 G 1/4 3TK
G 1/4
38
IE/FPC-1/00-2017
®
Sect. II - FPL Cavity 3 3 DA ** **
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
3 DB **
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEL003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AF 3 DD **
Drawing
Symbol
Drawing
FPL
Piloted solenoid valves normally open, with emergency Description
AE
3 FA
Code (valve + connector)
**
AD
Symbol
Piloted solenoid valves normally closed, with emergency Description
AC
H
Code (valve + connector)
**
3 DC **
3
Piloted solenoid valves normally closed, without emergency
Voltage 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Voltage 48 Vdc
Code (valve + connector)
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
II
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Piloted solenoid valves normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
*
Button operated valves
**
Description
A
Push-button control
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
IE/FPC-1/00-2017
Code CPE04P000.1
Code
39
®
Sect. II - FPL Cavity 3 3 FB
3
A
*
Unidirectional flow control valves compensated
*
Description
A
Screw adjustment
CSC04C0000
B
Plastic knob adjustment
CSC04V0000
**
Pressure relief valves
**
Description
Min 80 - Max 140
CMP04E2001
Min 100 - Max 330
CMP04E3001
Min 10 - Max 70
CMP04C1001
Min 80 - Max 140
CMP04C2001
BC
Min 100 - Max 330
CMP04C3001
CA
Min 10 - Max 70
CMP04V1001
Min 80 - Max 140
CMP04V2001
CC
Min 100 - Max 330
CMP04V3001
DA
Min 10 - Max 70
CMP04P1001
Min 80 - Max 140
CMP04P2001
Min 100 - Max 330
CMP04P3001
Short screw adjustment
AC BA BB
CB
DB
Screw adjustment
Plastic knob adjustment
Short screw + sealed cap
DC
3
3
40
B
T
Code CMP04E1001
AB
II
Regolazione (bar) Min 10 - Max 70
AA
FPL
Code
*
One-way check valves
*
Opening pressure
A
0,7 bar (Standard)
CRU0400002
B
4,5 bar
CRU0404002
C
10 bar
CRU0410002
*
Plugs and fittings
*
Description
D
Fitting 3/4 16 UNF - G1/4
20001700
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF - DIN G1/4
20018000
Code
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
IE/FPC-1/00-2017
®
Sect. II - FPL Cavity 4 Cavity Type Features FPL** ** (...) 2
.. ** 3
.. ** 4
.. **
A
4DA**
4DB**
B
D
C
3
2
4DC** 1
4 4DD** 8
FPL
7
4C*
II 4H*
4B*
A
D
B
C
4FA*
4Z*
4TE
2
3
4
1
4TF
G 1/4
8
7
4TK
G 1/4
IE/FPC-1/00-2017
41
®
Sect. II - FPL Cavity 4 4 DA ** **
Description
AA
Voltage 12 Vdc
CRP0418NCASL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NCASM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCASA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCASJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCASI003 + V86050002
4 DB **
FPL
Piloted solenoid valves normally closed, without emergency Code (valve + connector)
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Piloted solenoid valves normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRP0418NCAEL003 + V8605002
AB
Voltage 24 Vdc
CRP0418NCAEM003 + V86050002
AC
Voltage 24 Vac 50 Hz
CRP0418NCAEA003 + V86050002
AD
Voltage 115 Vac 50 Hz
CRP0418NCAEJ003 + V86050002
AE
Voltage 230 Vac 50 Hz
CRP0418NCAEI003 + V86050002
II 4 DC ** **
Description
AA
Voltage 12 Vdc
CRP0418NAAEL003 + V86050002
AB
Voltage 24 Vdc
CRP0418NAAEM003 + V86050002
AC AD AE AF
4 DD **
4
42
C
Piloted solenoid valves normally open, with emergency
Tensione 24 Vac 50/60 Hz (RAC with rectifier) Voltage 115 Vac 50 - 120 Vac 60 Hz (RAC with rectifier) Voltage 230 Vac 50 - 240 Vac 60 Hz (RAC with rectifier) Tensione 48 Vdc
Code (valve + connector)
CRP0418NAAE2003 + V86200002 CRP0418NAAEZ003 + V86200002 CRP0418NAAEX003 + V86200002 CRP0418NAAEN003 + V86050002
Direct operated solenoid valve normally closed, with emergency
**
Description
Code (valve + connector)
AA
Voltage 12 Vdc
CRD0418NCAEL002 + V86050002
AB
Voltage 24 Vdc
CRD0418NCAEM002 + V86050002
*
Lever operated valve
**
Description
A
Without microswitch
CMF04L0001
B
With microswitch
CMF04M0001
Code
IE/FPC-1/00-2017
®
Sect. II - FPL Cavity 4 4
4
B
H
4 FA
4
4
Z
T
*
One-way check valves
*
Opening pressure
A
0,7 bar (Standard)
CRU0400002
B
4,5 bar
CRU0404002
C
10 bar
CRU0410002
*
Button operated valves
**
Description
A
Push-button control
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Hand pumps
*
Description
A
Displacement 1 cc
CPM0410001
B
Displacement 2 cc
CPM0420001
*
Plugs and fittings
*
Description
E
Long plug 3/4 16 UNF
20003800
F
Fitting 3/4 16 UNF - G1/4
20009400
K
Fitting 3/4 16 UNF DIN - G1/4
20018000
IE/FPC-1/00-2017
Code
Code
Symbol
Drawing
Symbol
Drawing
CPE04P000.1
FPL Code
Code
Code
Symbol
Drawing
II
Symbol
Drawing
Symbol
Drawing
43
®
Sect. II - FPL Cavity 7-8 Return cavities FPL** ** (...) 2
.. ** 3
.. ** 4
.. ** 7 * 8 * Optional flow control valves
Return cavity, omit if not required flow control valves
A
B
D
C
3
2
1
4
A
FPL
8
D
B
C
7
II
8*
7*
2
3
4
1
8 7 Optional flow control valves
7 8
44
*
Flow control valves for return cavities ”7-8”
*
Nominal flow at 120 bar
A
0.7 l/min
VSC06100002
B
1.1 l/min
VSC06120002
C
2.1 l/min
VSC06130002
E
3.2 l/min
VSC06150002
G
4.7 l/min
VSC06190002
Code
K
6.3 l/min
VSC06220002
N
7.5 l/min
VSC06240002
Q
10.0 l/min
VSC06280002
U
13.2 l/min
VSC06330002
V
15.7 l/min
VSC06350002
Symbol
Drawing
IE/FPC-1/00-2017
®
Sect. II - FPL Ports A-B-C-D Possible combinations plugs on ports End section II FPL** ** (...) 2
.. ** 3
.. ** 4
A
B
.. ** 7 * 8 * -** -
D
C
A D B
FPL
3
2
1
4
8
7
2
3
4
1
8
-**
C
7
Possible combinations plugs on ports A-B-C-D
-**
A
B
C
D
Symbols description
-00
n
n
Type Description
-01
n
n
n
n
-03
n
n
n
-04
n
n
n
IE/FPC-1/00-2017
Port closed with plug
n
Open port
Thread
Code
G 1/4”
20024000 —
Symbol
Drawing
—
—
45
II
®
Sect. I - FPE Cavity 1 A
Pressure relief valve - Check valve - Plug Setting type (or plug features) Special setting pressure relief valve (omit if not required)
D
C
B
2
3
FPE** * * (...)
1
9 A
B
D
C
A1 B1 C1 A2 B2 C2
3 2
A3 B3 C3
1
K1
9
FPE
X1
I
*
*
*
*
Pressure relief valve with check valve
(...)
Pressure (bar)
STD setting (bar)
(...) Special setting (bar)
50
10 ÷ 60 (5 to 5)
1 A
2
10 ÷ 60
3 1 B
2
> 60 ÷ 180
150
65 ÷ 180 (5 to 5)
3 1 C
2
> 180 ÷ 320
210
190 ÷ 320 (10 to 10)
3
Setting type
Code
Detachable closing
CMPR04S01001
Non removable closing (1)
CMPR04P01001
Handwheel
CMPR04V01001
Detachable closing
CMPR04S02001
Non removable closing (1)
CMPR04P02001
Handwheel
CMPR04V02001
Detachable closing
CMPR04S03001
Non removable closing (1)
CMPR04P03001
Handwheel
CMPR04V03001
Symbol
Drawing
1
2
3
1 = Supplied assembled. Unassembled, see accessories page 89.
*
*
Check valve and plug
*
*
Description
K
1
Check valve - Opening pressure 0.5 bar
CRI0400001
X
1
Plug
R78150100
46
Code
Symbol
Drawing
IE/FPE-1/02-2017
®
Sect. II - FPE Cavity 2 Cavity Type Features
FPE** ** (...) 2 D(**) **
22D(1A)**
2
4
3
1
2
4
S2
22D(1B)**
3
4
1
S1
22D(1C)**
3
1
2
4
3
1
2
4
3
1
2
4
S2
22D(1D)**
C
3 2
S1
S2
2D(2A)**
3
D
2
S2
4
B
S1
S2
S1
A
1
S1
3
1
2D(2B)**
2
4
3
1
2D(2C)**
2
4
3
1
2D(2D)**
2
4
3
1
2D(2E)**
2
4
3
1
2D(3A)**
2
4
3
1
2D(3B)**
2
4
9
FPE II
2 1
A
D
B
C
2
3
1
4
3
3
1
2D(3C)**
2
4
3
1
2D(3D)**
2
4
3
1
2D(3E)**
2
4
3
1
2 1
IE/FPE-2/03-2017
9
47
®
Sect. II - FPE Cavity 2 2 D(**) ** Solenoid valves 4 way 3 positions with emergency (**) **
Description
Code (valve + connectors)
(1A)AA
Voltage 12 Vdc (closed centre “C” spool)
C4V0422C3FEL001 + V86050002 (x2)
(1A)AB
Voltage 24 Vdc (closed centre “C” spool)
C4V0422C3FEM001 + V86050002 (x2)
(1B)AA
Voltage 12 Vdc (open centre “A” spool)
C4V0422A3FEL001 + V86050002 (x2)
(1B)AB
Voltage 24 Vdc (open centre “A” spool)
C4V0422A3FEM001 + V86050002 (x2)
(1C)AA
Voltage 12 Vdc (centre “H” spool)
C4V0422H3FEL001 + V86050002 (x2)
(1C)AB
Voltage 24 Vdc (centre “H” spool)
C4V0422H3FEM001 + V86050002 (x2)
3
1
2
4
3
1
(1D)AA
Voltage 12 Vdc (centre “Y” spool)
C4V0422Y3FEL001 + V86050002 (x2)
(1D)AB
Voltage 24 Vdc (centre “Y” spool)
C4V0422Y3FEM001 + V86050002 (x2)
Symbol 2
4
3
1
2
4
3
1
2
4
S2
Drawing S1
S2
S1
S2
3
4
S1
2 1
S2
S1
S2
S1
2 D(**) ** Solenoid valves 4 way 2 positions without emergency (**) **
FPE
Description
Code (valve + connectors)
(2A)AA
Voltage 12 Vdc (closed centre “C” spool)
C4V0422C2FSL001 + V86050002
(2A)AB
Voltage 24 Vdc (closed centre “C” spool)
C4V0422C2FSM001 + V86050002
(2B)AA
Voltage 12 Vdc (open centre “A” spool)
C4V0422A2FSL001 + V86050002
(2B)AB
Voltage 24 Vdc (open centre “A” spool)
C4V0422A2FSM001 + V86050002
(2C)AA
Voltage 12 Vdc (centre “H” spool)
C4V0422H2FSL001 + V86050002
(2C)AB
Voltage 24 Vdc (centre “H” spool)
C4V0422H2FSM001 + V86050002
(2D)AA
Voltage 12 Vdc (centre “Y” spool)
C4V0422Y2FSL001 + V86050002
(2D)AB
Voltage 24 Vdc (centre “Y” spool)
C4V0422Y2FSM001 + V86050002
Symbol 2
4
3
1
2
4
3
Drawing
1
2
4
3
1
2
4
4
II
(2E)AA
Voltage 12 Vdc (direct “D” spool)
C4V0422D2FSL001 + V86050002
(2E)AB
Voltage 24 Vdc (direct “D” spool)
C4V0422D2FSM001 + V86050002
3
2 1
3
1
2
4
3
1
2 D(**) ** Solenoid valves 4 way 2 positions with emergency (**) **
Description
Code (valve + connectors)
Symbol 2
(3A)AA
Voltage 12 Vdc (closed centre “C” spool)
C4V0422C2FEL001 + V86050002
(3A)AB
Voltage 24 Vdc (closed centre “C” spool)
C4V0422C2FEM001 + V86050002
3
1
2
4
(3B)AA
Voltage 12 Vdc (open centre “A” spool)
C4V0422A2FEL001 + V86050002
(3B)AB
Voltage 24 Vdc (open centre “A” spool)
C4V0422A2FEM001 + V86050002
(3C)AA
Voltage 12 Vdc (centre “H” spool)
C4V0422H2FEL001 + V86050002
(3C)AB
Voltage 24 Vdc (centre “H” spool)
C4V0422H2FEM001 + V86050002
(3D)AA
Voltage 12 Vdc (centre “Y” spool)
C4V0422Y2FEL001 + V86050002
(3D)AB
Voltage 24 Vdc (centre “Y” spool)
C4V0422Y2FEM001 + V86050002
Drawing
4
3
1
2
4
3
1
2
4
4
48
(3E)AA
Voltage 12 Vdc (direct “D” spool)
C4V0422D2FEL001 + V86050002
(3E)AB
Voltage 24 Vdc (direct “D” spool)
C4V0422D2FEM001 + V86050002
3
2 1
3
1
2
4
3
1
IE/FPE-2/03-2017
®
Sect. II - FPE Cavity 3 Cavity Type Features Flow control valve can be combined with plug TC FPE** ** (...) 2 D(**) ** 3
A
.. ** +*
B
D
C
3FA*
3FB*
3 2
+*
3TC
1
Optional flow control valve 9
FPE II A
D
B
C
3
2
1
9
IE/FPE-2/03-2017
49
®
Sect. II - FPE Cavity 3 3 FA
3 FB
3
T
*
Bidirectional flow control valves not compensated
*
Description
A
Screw adjustment
CSB04C0000
B
Plastic knob adjustment
CSB04V0000
*
Bidirectional flow control valves compensated
*
Description
A
Screw adjustment
CSC04C000
B
Plastic knob adjustment
CSC04V000
*
Code
Code
Symbol
Drawing
Symbol
Drawing
Symbol
Drawing
Plugs and fittings
*
Description
Code
C
Plug 3/4 16 UNF (1)
C
+*
Flow control valves (1)
*
Flow
R78150099
FPE 3
T
II
50
Code
+B
1.4 l/min
VSC040101
+C
2.3 l/min
VSC040201
+E
2.8 l/min
VSC040301
+G
4.3 l/min
VSC040401
+J
5.2 l/min
VSC040601
+L
6.5 l/min
VSC040801
+N
8.0 l/min
VSC041101
+Q
11.1 l/min
VSC041601
Symbol
Drawing
(1) I The flow control valvee can be installed with the plug TC
IE/FPE-2/03-2017
®
Sect. II - FPE Cavity 9 Return cavity FPE** ** (...) 2 D(**) ** +* 3
.. ** +* 9 * Optional flow control valve
Return cavity, omit if not required flow control valve
A
B
D
C
3 2
1
A
D
B
C
9
2
3
FPE
1
Optional flow control valve
9*
II 9
9
*
Flow control valves
*
Nominal flow at 120 bar
A
0.7 l/min
VSC06100002
B
1.1 l/min
VSC06120002
C
2.1 l/min
VSC06130002
E
3.2 l/min
VSC06150002
G
4.7 l/min
VSC06190002
K
6.3 l/min
VSC06220002
N
7.5 l/min
VSC06240002
Q
10.0 l/min
VSC06280002
U
13.2 l/min
VSC06330002
V
15.7 l/min
VSC06350002
IE/FPE-2/03-2017
Code
Symbol
Drawing
51
®
Sect. II - FPE Ports A-B-C-D Possible combinations plugs on ports End section II FPE** ** (...) 2 D(**) ** +* 3
A
.. ** +*
B
9 * -** -
D
A
C
D
B
C
3
2
2
3
1
FPE
1 9
II 9
-**
Possible combinations plugs on ports A-B-C-D Symbols description
-**
A
B
C
D
-00
n
n
n
-01
n
n
n
-03
n
n
-04
n
n
Type Description
Port closed with plug
n
Open port
Code
Symbol
Drawing
—
—
20024000
—
With the FPE hydraulic power pack, cannot be mounted the standard blocks.
52
IE/FPE-2/03-2017
®
Sect. III - Pumps Pump Pump group Performance level Nominal displacement Accessories (omit if not required) End section III P
14
5
Pumps group 05 - Performance level 1
Ø 22
Ø 32
P 0 (1) **
* (*) ** / * -
G1/4
FP ........
L1
Tanks not compatible (•)
**
Nominal displacement
Tolerance on geometric displacement
P2 bar
P3 bar
Code complete kit
L1 mm
02
0.25 cc
0.25 ÷ 0.33
230
270
17050037.035
54
04
0.45 cc
0.45 ÷ 0.55
230
270
17050036.035
55.7
05
0.56 cc
0.56 ÷ 0.68
230
270
17050039.035
56.7
•
•
07
0.75 cc
0.69÷ 0.82
230
270
17050038.035
58.5
•
•
09
0.92 cc
0.83 ÷ 0.95
230
270
17050053.035
59.8
•
•
S09E
S02G
Motors not compatible
All
(H) (V) (H) (V) (H) (V) (H) (V)
P2 = Intermittent operating pressure P3 = Intermittent peak pressure (20 sec. max)
M4FB(1) - M4GJ(1) MM*PA(1) M*AA(1)D - M*AA(1)G M*AA(1)H M*AB(1)D - M*AB(1)G M*AB(1)H
Tanks not compatible (as dimensions, see page 55) Motors not compatible (interface and transmission not supplied, see pages 71 - 77)
Pumps group 1 - Performance level 1
G3/8
5
Ø 32
P 1 (1) **
S01A
III
L1
Tanks not compatible (•) S01A S09E S02G All (H) (V) (H) (V) (H) (V) (H) (V) •
**
Nominal displacement
Tolerance on geometric displacement
P2 bar
P3 bar
Code complete kit
L1 mm
07
0.80 cc
0.69 ÷ 0.82
170
210
17050107.018
72.4
10
1.00 cc
0.96 ÷ 1.09
170
210
17050088.018
73.5
•
12
1.20 cc
1.10 ÷ 1.30
250
290
17050005.018
74.8
•
17
1.70 cc
1.50 ÷ 1.70
250
290
17050006.018
76.2
•
22
2.20 cc
2.10 ÷ 2.30
250
290
17050007.018
78.2
•
26
2.60 cc
2.50 ÷ 2.70
250
290
17050008.018
79.7
•
•
32
3.20 cc
3.10 ÷ 3.32
250
290
17050009.018
82.0
•
•
38
3.80 cc
3.60 ÷ 3.99
250
290
17050010.018
84.0
•
•
43
4.30 cc
4.00 ÷ 4.35
250
290
17050011.018
86.6
•
•
48
4.80 cc
4.85 ÷ 4.95
225
260
17050033.018
88.1
•
•
60
6.00 cc
5.62 ÷ 6.02
185
215
17050012.018
92.2
•
78
7.80 cc
7.48 ÷ 7.90
140
160
17050013.018
98.9
• • • • • •
98
9.80 cc
9.60 ÷ 10.00
110
125
17050054.018
107.2
P2 = Intermittent operating pressure P3 = Intermittent peak pressure (20 sec. max)
• • • •
• • • • • • Tanks not compatible (as dimensions, see page 55) .
53
®
Sect. III - Pumps /*
Accessories for pumps group 1
*
Description
/A /B
Single-phase motor start valve - on auxiliary outlet
/C
Type
Code
0.8 ÷ 2.5 l/min > 2.5 ÷ 8.0 l/min > 8.0 ÷ 14 l/min
Symbol 60.5
VAM0400L VAM0400M
P
T
T
VAM0400H
Displacement
69
** 09 12 17 22 26 32
III
38 43
/D
Soft start valve - on auxiliary outlet
hole Ø 0.4 mm max 8 l/min
P
T
T
12.5
With accessory /A /B /C /D /A /B /C /D /A /B /C /D /A /B /C /D /A /B /C /D /A /B /C /D /A /B /C /D /A /B /C /D
Tanks not compatible (•) S01A S09E S02G All •
•
•
•
•
•
•
•
•
•
•
•
•
• • • • • • •
• • • • • • •
• • • • •
Tanks not compatible (as dimensions, see page 55) .
54
VAMS0404001
Ø 5.5
P 1 (1) **
®
Sect. IV - Tanks / Sect. V - Tubes kit
Tank (S = with tank and tubes kit; G = only tubes kit, without tank; OMIT if without tank and without tubes kit) Capacity liters Features (material and construction) Mounting position: (H = horizontal; V = vertical) Variants (00 = standard, no variant) - OMIT if with tubes kit Orientation - OMIT if with tubes kit in vertical mounting position End section IV and V FP ........
* ** * (*) **
**
Liters
01
1 1,5
/* -
* Dimensions (mm) Material A Ø 123 - L 141 G
Sheet steel
130x140 - L 135 Polyethylene
02 2 2,5
A Ø 123 - L 200 G
Sheet steel
130x140 - L 235 Polyethylene
03 3
A Ø 123 - L 330
Sheet steel
4
G
130x140 - L 295 Polyethylene
4
L
180 - L 210
5
B Ø 175 - L 246
Sheet steel
5
C Ø 200 - L 210
Sheet steel
5
F
Polypropylene
6
B Ø 175 - L 308
7
E
04
05
06
07
180 - L 240
Polyethylene
Sheet steel
154x188 - L 299 Sheet steel
7
F
180 - L 308
Polypropylene
7
L
180 - L 310
Polyethylene
7
M
180 - L 335
Polyethylene
8
B Ø 175 - L 370
Sheet steel
8
C Ø 200 - L 306
Sheet steel
08
E
230x130 - L 350 Sheet steel
L
180 - L 370
Polietilene
10
C Ø 200 - L 373
Sheet steel
10
D Ø 217 - L 273
Sheet steel
10
L
Polyethylene
12
12
D Ø 217 - L 370
14
14
E
255x193 - L 366 Sheet steel
25
25
E
250x255 - L 436 Sheet steel
09
10
IE/FP-4-5/06-2017
9
180 - L 410
Sheet steel
(*) Mounting (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (H) (V) (V) (H) (V) (H) (V) (H) (V) (H) (V) (V) (H) (V)
** Variants 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00-01-02-03-04 00 00 00 00 00 00-04 00 00-01 00 00 00 00 00 00 00-04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00-01 00-01 00-01
Page
* Orientation
Page
/1(std) /2 /3 /4
69
56 65 56 65 56 65 66 57 58 64 57 60 64
IV V
67 68 57 58 61 67 58 59 67 59 62 63
55
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Horizontal mounting (black painted)
01
141
1
1.0
0.7
90310000
02 A (H) 00
200
2
1.6
1.5
90310001
03
330
3
3
2.8
90310002
37
Tank fixing kit (screws and O-Ring)
(49149800)
Ø 123
Usable
Tank (with plug)
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
17010080
L
(..) spare parts
(1 ) Variant - OMIT if without tank but with tubes kit
Other variants Variant
*
Tank
** * (V) **
Variant
Tank
Variant
Tank
Variant
* - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Vertical mounting (black painted) (49149800)
01
141
1
0.9
0.7
90310009
02 A (V) 00
200
2
1.6
1.5
90310010
03
330
3
2.9
2.9
90310011
101
Tank fixing kit (screws and O-Ring)
(60502700)
L
Usable
Tank (with plug)
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
IV V
Tank
17010080 Ø 123
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
56
Tank
Variant
Tank
Variant
Tank
Variant
Tank
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Horizontal mounting (black painted)
05
246
5
4.7
4.5
90310003
06 B (H) 00
308
6
6
5.9
90310004
51
Tank fixing kit (screws and O-Ring)
(49149800)
Ø 175
Usable
Tank (with plugs)
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
17010080
25 L
370
08
8
8
7.3
(R78100021)
90310005
(..) spare parts
(1 ) Variant - OMIT if without tank but with tubes kit
Other variants Variant 05 06 08
B
Tank 90310003
Variant 05 06 08
(H) 01
B
(H) 02
(49149800)
** * (V) **
Variant 05 06 08
B
(H) 03
Tank 90310134 90310062 90310069
Variant 05 06 08
B
Tank 90310176
(H) 04
(49107500)
(60306400)
(R78100021)
(R78100021)
*
Tank 90310149
(49121900)
(R78100021)
(R78100021)
* - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Vertical mounting (black painted)
05
246
5
4.3
4.1
90310012
06 B (V) 00
308
6
5.8
5.5
90310013
08
370
8
7.5
7.2
90310015
Tank fixing kit (screws and O-Ring)
127
(49149800)
IV V
L
Usable
Tank (with plugs)
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
(60502700)
17010080
Ø 175
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
(R78100021)
Other variants Variant
IE/FP-4-5/06-2017
Tank
Variant
Tank
Variant
Tank
Variant
Tank
57
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Tanks Ø 200 - Sheet steel, capacity 5-8-10 liters - Horizontal mounting (black painted)
05
205
5
5.3
5.0
90310425
08 C (H) 00
301
8
8.0
7.7
90310428
10
368
10
10
9.3
90310431
(49149800)
Tank fixing kit (screws and O-Ring)
L
Ø 200
Usable
Tank (with plugs)
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
17010080 (..) spare parts
(R78100021)
(1 ) Variant - OMIT if without tank but with tubes kit
Other variants Variant
Tank
Variant
Tank
Variant 05 08 10
C
(H) 03
Tank 90310453 90310443 90310483
Variant
Tank
(49107500)
(R78100021)
*
** * (V) **
* - Tanks Ø 200 - Sheet steel, capacity5-8-10 liters - Vertical mounting (black painted)
05
205
5
4.6
4.3
90310444
08 C (V) 00
301
8
7.5
7.1
90310437
10
368
10
9.5
9.1
90310439
(49149800)
Tank fixing kit (screws and O-Ring)
(R78100021) L
Usable
Tank (with plugs)
Full
L (mm)
Nominal
Variant (1)
Mounting
IV V
Features
Capacity
Capacity (liters)
17010080 Ø 200
(..) spare parts
(1 ) Variant - OMIT if without tank but with tubes kit
Other variants Variant
58
Tank
Variant
Tank
Variant
Tank
Variant
Tank
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Horizontal mounting (black painted) 220 (12 liters) Ø 11
8
7.6
90310006
370
12
12
11
90310058
72
17010080
D (H) 00 12
150
10
(12 liters)
273
(12 liters)
Tank fixing kit (screws and O-Ring)
(49105800)
81
(1 ) Variant - OMIT if without tank but with tubes kit
Ø 217
Usable
Tank (with plugs)
Full
10
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
L
Other variants Variant
*
(..) spare parts Tank
** * (V) **
Variant
Tank
Variant
(20018500)
Tank
Variant
* - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Vertical mounting (black painted) (491105800)
10
7
6.8
167
Tank (with plugs)
90310029 17010080
D (V) 00 370
12
Tank fixing kit (screws and O-Ring)
12
10.3 10.1
IV V
(MEG5121200)
L
Usable
273
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
10
Tank
90310100
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
(20018500)
Other variants Variant
IE/FP-4-5/06-2017
Tank
Variant
Tank
Variant
Tank
Variant
Tank
59
®
Sect. IV - Tanks / Sect. V - Tubes kit * - Rectangular tanks - Sheet steel, capacity 7 liters - Vertical mounting (black painted) (49154200)
17010080
200
90310014
(49154200) 215,5
11 N°4
45
37
(1 ) Variant - OMIT if without tank but with tubes kit
178
5.1
97
Usable
5.5
Tank fixing kit (screws and O-Ring)
88
Full
7
Tank (with plugs)
22
Nominal
299
Mounting
07 E (V) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
112
** * (V) **
154
*
62,5 7
80
183 L
(..) spare parts
Other variants 07
Variant E (V) 01
Tank 90310036
Variant
Tank
Variant
Tank
Variant
Tank
(49107500)
(49154200)
IV V
60
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit ** * (H) **
* - Rectangular tanks - Sheet steel, capacity 9 liters - Horizontal mounting (black painted) (49149800)
Usable
9
8
Tank fixing kit (screws and O-Ring)
90310142
17010080
(R78100021) 230
Full
9
Tank (with plugs)
22
93
Nominal
350
Mounting
09 E (H) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
12
*
25
211
Variant
Tank
Variant
Tank
Variant
Tank
Variant
* - Rectangular tanks - Sheet steel, capacity 9 liters - Vertical mounting (black painted)
Tank (with plugs)
133
Usable
Full
Nominal
Variant (1)
Mounting
Features
L (mm)
Tank fixing kit (screws and O-Ring)
12
(49149800)
Capacity (liters) Capacity
Tank
22 130
** * (V) **
L
(..) spare parts
Other variants
*
133
130 22
(1 ) Variant - OMIT if without tank but with tubes kit
IV V
350
9
8.6
7.5
90310142
211
17010080
25
93
09 E (V) 00
22
(R78100021)
230
(1 ) Variant - OMIT if without tank but with tubes kit
236
(..) spare parts
Other variants Variant
IE/FP-4-5/06-2017
L
Tank
Variant
Tank
Variant
Tank
Variant
Tank
61
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (*) **
* - Rectangular tanks - Sheet steel, capacity 14 liters - Vertical mounting (black painted)
Usable
14
13
90310045
17010080
(49149800)
12
Tank fixing kit (screws and O-Ring)
219
Full
14
Tank (with plugs)
193 22
Nominal
366
Mounting
14 E (V) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
(49154200) L
(1 ) Variant - OMIT if without tank but with tubes kit
265 220
11
277.5 94
91 300
37
(..) spare parts
20 75
73
Other variants 14
Variant E (V) 01
Tank 90310046
Variant
Tank
Variant
Tank
Variant
Tank
(49107500)
(49154200)
IV V
62
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit * - Rectangular tanks - Sheet steel, capacity 25 liters - Horizontal mounting (black painted)
** * (*) **
Usable
22
21
Tank fixing kit (screws and O-Ring)
90310060
17010080
(20022600) 105 183.5
Full
25
Tank (with plugs)
(25)
16.5 n°4
L
60
(16)
(1 ) Variant - OMIT if without tank but with tubes kit
474
(16)
250
200
46
Nominal
Variant (1)
Mounting
436
Features
25 E (H) 00
Capacity
L (mm)
46 (49118000)
19
Capacity (liters)
35 255
*
(25)
506
(..) spare parts
Other variants 25
Variant E (H) 01
Tank 90310083
Variant
Tank
Variant
Tank
Variant
Tank
(49120600)
(20022600)
Usable
25
22
Tank fixing kit (screws and O-Ring)
90310071
17010080
(49118000) 46
(25)
16.5 n°4
(20022600)
IV V
200 (16)
125 60
(1 ) Variant - OMIT if without tank but with tubes kit
250
46
Full
25
Tank (with plugs)
100
281 35
Nominal
436
Mounting
25 E (V) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
33.5
* - Rectangular tanks - Sheet steel, capacity 25 liters - Vertical mounting (black painted)
255
** * (*) **
26
*
L 474
(25) (16)
506
(..) spare parts
Other variants 25
Variant E (V) 01
Tank 90310124
Variant
Tank
Variant
Tank
Variant
Tank
(49120600)
(20022600)
IE/FP-4-5/06-2017
63
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Square polypropylene tanks capacity 5-7 liters - Horizontal mounting
4.5
(49138700)
180
5.4
Tank fixing kit (screws and O-Ring)
90310313 17010083
F (H) 00 306
07
90
242
05
7
Operating temperature -10°C ÷ +60°C -
7.4
190
Usable
5
Tank (with plug, brackets, nuts)
105
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
L
90310289
6.5
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
*
Tank
** * (V) **
Variant
Tank
Variant
Tank
Variant
* - Square polypropylene tanks capacity 5-7 liters - Vertical mounting
Usable
5
5.4
4.5
Tank (with plug, brackets, nuts)
90
Tank fixing kit (screws and O-Ring)
105
(49138700) L
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
IV V
Tank
242
05
90310313 17010083
F (V) 00 306
07
7
Operating temperature -10°C ÷ +60°C -
7.4
6.5
90310289
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
64
Tank
Variant
Tank
Variant
Tank
Variant
Tank
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit * - Square polyethylene tanks capacity 1.5-2.5-4 liters - Horizontal mounting
135
1.5
1.3
1
90310491
03 G (H) 00
235
2.5
2.5
2
90310484
04
295
4
3.4
2.5
90310422
35
MAX
140
Usable
02
Tank fixing kit (screws and O-Ring)
94
Full
Tank (with plugs, clamp, nuts)
Nominal
Variant (1)
Mounting
Features
Capacity
L (mm)
(C86100001)
(V60513005)
Capacity (liters)
70
** * (H) **
104.5
*
Operating temperature -10°C ÷ +70°C -
MIN
MAX
MIN
17010081
130
L
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
*
Tank
** * (V) **
Variant
Tank
Variant
Tank
Variant
* - Square polyethylene tanks capacity 1.5-2.5-4 liters - Vertical mounting
Full
Usable
Tank (with plugs, clamp, nuts)
Nominal
02
135
1.5
1.1
0.7
90310486
03 G (V) 00
235
2.5
2.7
2.3
90310419
04
296
4
3.5
3.1
90310402
IV V
MAX
MIN
Operating temperature -10°C ÷ +70°C -
02 = 49153500 03-04 = 49138700
Tank fixing kit (screws and O-Ring) L
Variant (1)
Mounting
L (mm)
MAX
Features
Capacity (liters) Capacity
Tank
17010081
MIN
(49154200)
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
IE/FP-4-5/06-2017
Tank
Variant
Tank
Variant
Tank
Variant
Tank
65
®
Sect. IV - Tanks / Sect. V - Tubes kit * - Square polyethylene tanks capacity 4 liters - Horizontal mounting (C86100001)
MAX
MIN MIN
17010081
MIN
90310331
95
3
MAX
MAX
180
Usable
3.6
35
(V60513005)
85
Full
4
Tank (with plugs, clamp, nuts)
Tank fixing kit (screws and O-Ring)
104.5
Nominal
210
Mounting
04 L (H) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
119
** * (H) **
90.5
*
L
180
(49154200)
Operating temperature -10°C ÷ +70°C -
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
*
Tank
** * (V) **
Variant
Tank
Variant
Tank
Variant
* - Square polyethylene tanks capacity 4 liters - Vertical mounting (49153500)
Tank fixing kit (screws and O-Ring)
MAX
MAX
MIN
L
Usable
Full
Nominal
Variant (1)
Mounting
Tank (with plugs, clamp, nuts)
MAX
Features
L (mm)
MIN
Capacity
Capacity (liters)
IV V
Tank
MIN
04 L (V) 00
210
4
Operating temperature -10°C ÷ +70°C -
3.7
3
90310332
17010081
(49154200)
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants 04
Variant L (V) 01
Tank 90310433
Variant
Tank
Variant
Tank
Variant
Tank
(49138700)
MAX MAX
MIN
MAX
MIN MIN
66
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit * - Square polyethylene tanks capacity 7-10 liters - Horizontal mounting
90310330
35 MAX
MAX
67
5.5
(V60513005)
MIN MIN MIN
6.7
Tank fixing kit (screws and O-Ring)
MAX
7
(C86100001)
Tank (with plugs, clamp, nuts)
102.5
Usable
310
07
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
85 95 180
** * (*) **
119
*
17010081
L (H) 00 410
10
10
8.7
7.5
20
L
180
90310339 (V60513005)
Operating temperature -10°C ÷ +70°C -
*
** * (*) **
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
* - Square polyethylene tanks capacity 7-10 liters - Vertical mounting 07= 49138700 10= 49153500
Full
Usable
6
MAX
310
07
MIN
L
Nominal
Variant (1)
Mounting
Features
6.7
Tank fixing kit (screws and O-Ring)
MAX
7
Tank (with plugs, clamp, nuts)
MAX
L (mm)
MIN
Capacity
Capacity (liters)
90310403 MIN
17010081
L (V) 00 410
10
10
Operating temperature -10°C ÷ +70°C -
9.8
9
90310338
(1 ) Variant - OMIT if without tank but with tubes kit
(V60513005)
(49154200)
(..) spare parts
IV V *
** * (*) **
* - Square polyethylene tanks capacity 9 liters - Vertical mounting
102
(49153500)
Usable
8.6
8
Tank fixing kit collar Ø123 (screws and O-Ring)
90310371
17010081
L
Full
9
Tank (with plugs, clamp, nuts)
21
Nominal
390
Mounting
09 L (V) 00
Features
L (mm)
Capacity
Variant (1)
Capacity (liters)
(V60513005)
(1 ) Variant - OMIT if without tank but with tubes kit 180
Operating temperature -10°C ÷ +70°C -
85 95 180
(..) spare parts
IE/FP-4-5/06-2017
67
®
Sect. IV - Tanks / Sect. V - Tubes kit *
** * (H) **
* - Special square polyethylene tanks capacity 7 liters - Horizontal mounting
Tank (with plugs, clamp, nuts)
Tank fixing kit (screws and O-Ring)
(49155600)
335
7
7.3
6.6
90310380
MIN MAX
17010081
67
07 M (H) 00
113 180
122
MAX
Usable
Full
L (mm)
Nominal
Variant (1)
Mounting
Features
Capacity
Capacity (liters)
MIN
180
L
Operating temperature -10°C ÷ +70°C -
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
*
Tank
** * (V) **
Variant
Tank
Variant
Tank
Variant
Tank
* - Special square polyethylene tanks capacity 7 liters - Vertical mounting
Full
Usable
7
7.2
6.4
MAX
L
Nominal
Mounting
335
Features
07 M (V) 00
Capacity
IV V
Tank (with plugs, clamp, nuts)
MAX
L (mm)
(49155600)
Tank fixing kit (screws and O-Ring) MIN
Variant (1)
Capacity (liters)
90310380
17010081 MIN
Operating temperature -10°C ÷ +70°C -
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
Other variants Variant
68
Tank
Variant
Tank
Variant
Tank
Variant
Tank
IE/FP-4-5/06-2017
®
Sect. IV - Tanks / Sect. V - Tubes kit *
**
/* - Tanks orientation according to the mounting position
*
(*)
**
For tamks
(*)
Mounting position
/* Orientation /2
/1 (standard)
/3
/4
Horizontal A
S
**
A B C D
A
(H) A A
(1)
For tamks
(*)
Mounting position
/* Orientation /1 (standard)
Horizontal
A
E
(H)
For tamks
(*)
S
09
Mounting position
/* Orientation /1 (standard)
Horizontal
IV V
A
E
(H)
For tamks
(*)
S
25
Mounting position
/* Orientation /2
/1 (standard)
/3
/4
Horizontal A
S
**
F G L
A
(H) A A
(1)
(1) Orientation TO BE USED with blocks
IE/FP-4-5/06-2017
69
69
®
Sect. IV - Tanks / Sect. V - Tubes kit *
**
/* - Tanks orientation according to the mounting position
*
(*)
**
For tamks
(*)
Mounting position
/* Orientation /1 (standard)
/2
/3
/4
Vertical
S
**
A B C D F G L
(V) A
A
A
A
(2)
For tamks
(*)
Mounting position
/* Orientation /1 (standard)
/2
/3
/4
Vertical
S
07
E
(V) A
A
A
A
(1)
For tamks
(*)
Mounting position
/* Orientation /1 (standard)
/2
/3
/4
Vertical
IV V
S
09 25
E
(V) A
A
A
A
(1)
For tamks
(*)
Mounting position
/* Orientation /1 (standard)
/2
/3
/4
Vertical
S
14
E
(V) A
A
A
A
(1)
(1) Orientation TO BE USED with blocks (2) DO NOT USE with blocksi
70
IE/FP-4-5/06-2017
®
Sect. VI - DC Motors Motor Voltage Power / Size Version Accessories Orientation End section VI All motors are equipped with a transmission kit (coupling and components for the assembly)
FP ........
M * ** (*) * /* -
*
Voltage
2
12 VDC
4
24 VDC
** GA GC AA EN GN GB GD AB ES GP GJ FB
Power 350 W 700 W 1500 W 1600 W 1600 W 400 W 800 W 2000 W 2200 W 2200 W 3000 W 3000 W
Size Ø 80 Ø 80 Ø 115 Ø 115 Ø 115 Ø 80 Ø 80 Ø 115 Ø 115 Ø 115 Ø 125 Ø 125
(*) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1)
Version Std Std Std Std Std Std Std Std Std Std Std Std
Page 72 72 73 73 74 72 72 73 73 74 74 74
* 0 B C D
E F G H
(•)
(•)
(•)
* Accessories 0-B 0-B 0-B-C-D-F-G-H 0-B-C-E 0-B-C-E 0-B 0-B 0-B-C-D-F-G-H 0-B-C-E 0-B-C-E 0-B-C-E 0-B-C-E
/* Orientation
/1 /2 Std /3 /4
Accessories description Without accessories Starting switch Thermal protection Ventilation Starting switch + thermal protection Starting switch + ventilation Thermal protection + ventilation Starting switch + thermal protection + ventilation
Page
76
Page — 75 — 75 — — — —
VI DC
(• )= IP protection level becomes effective after installationon on power pack. Acquires IP 10 level with “ventilation” accessory.
For more details, features and performances DC motors, see catalog code DOC00053.
IE/FP-6DC/04-2017
71
®
Sect. VI - DC Motors Motors: 12 VDC 350 W / 24 VDC 400 W (permanent magnets) M
2 GA (1) * /*
M
4 GB (1) *
/*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
12 VDC
350
40
3300
1.0
10
35
54
F
80
25021400
24 VDC
400
30
3100
1.2
5
20
54
F
80
25021500
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
7 n.2
Ø 80
6.40 M6 n.2
101
Ø 80
M
*
** (*)
*
/* - Accessories (page 75)
*
Description
0
Without accessories
B Starting switch 120A fixing with clamp 13.80 MAX
143.5
Code trasmission kit: page 83
Motors: 12 VDC 700 W / 24 VDC 800 W (permanent magnets) M
2 GC (1) * /*
M
4 GD (1) * /*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
12 VDC
700
90
3300
2.0
2.5
10
54
F
80
25021600
24 VDC
800
70
3000
2.5
2
5
54
F
80
25021700
** (*)
*
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
VI
7 n.2
M
DC
*
/* - Accessories (page 75)
Ø 80 6.40
101
Ø 80
* Description 0 Without accessories B Starting switch 120A M6 n.2
162
13.80 MAX
Code trasmission kit: page 83
For more details, features and performances DC motors, see catalog code DOC00053.
72
IE/FP-6DC/04-2017
®
Sect. VI - DC Motors Motors: 12 VDC 1500 W / 24 VDC 2000 W (wound field compound) M
2 AA (1) * /*
M
4 AB (1) * /*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
12 VDC
1500
225
2500
5.5
1
5
54
F
115
25022200
24 VDC
2000
150
2250
8
2
5
54
F
115
25022300
** (*)
*
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
M M8
173
/* - Accessories (page 75)
0 Without accessories B Starting switch 120A
11 MAX 12.3 MAX
*
* Description Ø98.3
6.4
Ø35
Ø112
Ø15
9.1 MAX
D Ventilation 1/4-20 UNC-2A
F Ventilation + Starting switch
91
G Ventilation + Thermal protection H Ventilation + Thermal protection + Starting switch Code trasmission kit: page 83
Acquires IP 10 protection level with “ventilation” accessory.
Motors: 12 VDC 1600 W / 24 VDC 2200 W (wound field compound) M
2 EN (1) * /*
M
4 ES (1) * /*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
12 VDC
1600
230
2600
5
2
10
54
F
115
25021100
24 VDC
2200
140
2700
8
1.2
5
54
F
115
25021200
** (*)
*
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
9.1
133
90.4
Ø35
M5 n°2
A2E2
Ø114
M8
D1E1
Ø15 6.4
M
*
VI
/* - Accessories (page 75)
DC
* Description 0 Without accessories B Starting switch 120A
1/4-20UNC 11 max 12.3
158
Ø98.32
C Thermal protection E Starting switch + thermal protection
Code trasmission kit: page 83
For more details, features and performances DC motors, see catalog code DOC00053.
IE/FP-6DC/04-2017
73
®
Sect. VI - DC Motors Motors: 12 VDC 1600 W / 24 VDC 2200 W (wound field serie) M
2 GN (1) * /*
M
4 GP (1) * /*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
12 VDC
1600
220
2600
6
4
8
54
F
115
25022600
24 VDC
2200
140
2600
6
2
7.5
54
F
115
25022700
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
M
*
** (*)
*
/* - Accessories (page 75)
* Description
M5 n°2
0 Without accessories
90.4
Ø35
Ø114.3
121.2
M8
Ø15 6.43
8.4
B Starting switch 120A 1/4-20UNC
9.1 11.8
161.8
Code trasmission kit: page 83
Ø98.32
Motors: 24 VDC 3000 W (wound field compound) M M
4 FB (1) * /* 4 GJ (1) * /*
Voltage
W
A
rpm
Nm
S2 min
S3%
IP
IC
Ø mm
Code (
)
24 VDC 24 VDC
3000 3000
200 180
3300 3500
8.5 8.5
4 3.5
15 15
20 20
F F
125 125
25021300 25022400
IP protection level becomes effective after installationon on power pack. (
) Motor without accessories
M
VI
Adapter: supplied with the transmission kit
**
102
Ø42
FB GJ
8
Ø125
M5 n°2
28.5 43
207.5 (M4FB) 200 (M4GJ)
** (*)
*
/* - Accessories (page 75)
* Description 0 Without accessories
M8
DC
*
M6
B Starting switch 150A D Ventilation F Ventilation + Starting switch G Ventilation + Thermal protection
FB H Ventilation + Thermal protection + Starting switch Code trasmission kit: page 83
For more details, features and performances DC motors, see catalog code DOC00053.
74
IE/FP-6DC/04-2017
®
Sect. VI - DC Motors *
** (*)
/* -
C
Thermal protection Ø mm For motors 16 M2EN - M4ES
Code 90340009
M
*
** (*)
/* -
B
Accessory: Thermal protection Ø
Accessory: Starting switch 182.5
72
64.5
57.3
Code (•) KIT07012.027 KIT07012.032 KIT07012.033 KIT07012.034 KIT07012.025 KIT07012.026
29
M6 N.2
starting switch For motors M2GA - M2GC M4GB - M4GD M2AA M4AB M2EN - M2GN M4ES - M2GP
Code (•) KIT07012.019
5
26
21
Ø 40
120A VDC 12 24 12 24 12 24
Female Faston 6.3-08 N.2
5
20
Ø 54.5
Female Faston 6.3-08 N.2
M8 N.2
M
150A starting switch VDC For motors 24 M4FB - M4GJ
(•) Complete kit with all assembly components.
For more details, features and performances DC motors, see catalog ode DOC00053.
M
*
** (*)
*
/* -
Accessory: Ventilation (motor included)
9 (N°4)
VI
5
118
118
5
9 (N°4)
DC 52.6
118
46
118
173
53.2
55.9
IP 10 protection
*
Code (•)
D
KIT09008.061
12
M2AA
G
KIT09008.062
12
M2AA + thermal protecion
D
KIT09008.031
24
M4AB
G
KIT09008.063
24
M4AB + thermal protecion
VDC For motors
207.5
IP 10 protection
*
Code (•)
D
KIT09008.029
VDC For motors 24
M4FB
(•) Complete kit with all assembly components (motor, transmission kit, etc).
For more details, features and performances DC motors, see catalog code DOC00053.
IE/FP-6DC/04-2017
75
®
Sect. VI - DC Motors M
*
** (*)
*
/* -
Motor orientation
Starting switch and poles position.
/1
Do not use “orientation 1” with blocks.
P Std
/4
/2
/3
VI DC
76
IE/FP-6DC/04-2017
®
Sect. VI - AC Motors
FP ........
M *
*
*
*
* (*) /* -
Phases
* Poles
2
M
Singlephase
4
2
T
Motor Phases Poles Size Power range Version Orientation End section VI
Threephase
4
*
Size
*
L L S S M M N N P L L S M M N N V V P R R L L S S M M T T N N P P R R L L S M M T T T T N N P P P
71 71 71 71 80 80 90 90 100 71 71 71 80 80 90 90 90 90 100 63 63 71 71 71 71 80 80 80 80 90 90 100 112 63 63 71 71 71 80 80 80 80 80 80 90 90 100 100 112
A B A B A B A B A A B C A B A B A B A A B A B A B A B A B A B A B A B A B A A B A B C D A B A B C
Power range Power Voltage 0.37 230 Vac 50 Hz 0.55 230 Vac 50 Hz 0.75 kW 230 Vac 50 Hz 1.10 kW 230 Vac 50 Hz 0.75 230 Vac 50 Hz 1.10 230 Vac 50 Hz 1.50 230 Vac 50 Hz 2.20 230 Vac 50 Hz 3.00 230 Vac 50 Hz 0.25 230 Vac 50 Hz 0.37 230 Vac 50 Hz 0.85 kW 230 Vac 50 Hz 0.55 230 Vac 50 Hz 0.75 230 Vac 50 Hz 1.10 230 Vac 50 Hz 1.50 230 Vac 50 Hz 1.80 kW 230 Vac 50 Hz 3.00 kW 230 Vac 50 Hz 2.20 230 Vac 50 Hz 0.18 kW 230/400 Vac 50 Hz 0.25 kW 230/400 Vac 50 Hz 0.37 kW 230/400 Vac 50 Hz 0.55 kW 230/400 Vac 50 Hz 0.75 kW 230/400 Vac 50 Hz 1.10 kW 230/400 Vac 50 Hz 0.75 kW 230/400 Vac 50 Hz 1.10 kW 230/400 Vac 50 Hz 2.70 kW 230/400 Vac 50 Hz 2.70 kW 230/400 Vac 50 Hz 1.50 kW 230/400 Vac 50 Hz 2.20 kW 230/400 Vac 50 Hz 3.00 kW 230/400 Vac 50 Hz 4.00 kW 230/400 Vac 50 Hz 0.12 kW 230/400 Vac 50 Hz 0.18 kW 230/400 Vac 50 Hz 0.25 kW 230/400 Vac 50 Hz 0.37 kW 230/400 Vac 50 Hz 0.75 kW 230/400 Vac 50 Hz 0.55 kW 230/400 Vac 50 Hz 0.75 kW 230/400 Vac 50 Hz 2.20 kW 230/400 Vac 50 Hz 2.20 kW 230/400 Vac 50 Hz 2.20 kW 230/400 Vac 50 Hz 3.00 kW 230/400 Vac 50 Hz 1.10 kW 230/400 Vac 50 Hz 1.50 kW 230/400 Vac 50 Hz 2.20 kW 230/400 Vac 50 Hz 3.00 kW 230/400 Vac 50 Hz 4.00 kW 230/400 Vac 50 Hz
Page 78 78 80 80 78 78 78 78 78 78 78 80 78 78 78 78 81 81 78 79 79 79 79 80 80 79 79 81 81 79 79 79 79 79 79 79 79 80 79 79 81 81 81 81 79 79 79 79 79
(*) Version
/* Orientation
(1) Std
/1 /2 Std /3 /4
Page
82
VI AC
Motors supplied with all assembly components (transmission kit, coupling, etc).
IE/FP-6AC/04-2017
77
®
Sect. VI - AC Motors
L2
D2
D1
H1
Adapter: supplied with the transmission kit
L1
Power range L1
(•)
(•)
(•)
Adapter Screw Code UNI L2 5931
Single Motor
Transmission kit (for pump)
Size
H1
Phases Poles
D1 D2
Cable gland metric thred
Single-phase motors 2-4 Poles - 230 Vac 50Hz - Version B14
M M 2 L A (1)
2 2
71
14 148 115 208
0.37
230 Vac 50 Hz
M M 2 L B (1)
2 2
71
14 148 115 208
0.55
230 Vac 50 Hz
M M 2 M A (1)
2 2
80
19 170 126 234
0.75
230 Vac 50 Hz
M M 2 M B (1)
2 2
80
19 170 126 234
1.10
230 Vac 50 Hz
M M 2 N A (1)
2 2
90
24 185 142 247
1.50
230 Vac 50 Hz
M M 2 N B (1)
2 2
90
24 185 142 272
2.20
230 Vac 50 Hz
54 F Si 20-25 61000900 M8x21 40.4 M14L2000 KIT08019.015 (Gr.05) 54 F Si 20-25 61000900 M8x21 40.4 M14N2000 KIT08019.016 (Gr.1)
M M 2 P A (1)
2 2 100 28 210 155 310
3.00
230 Vac 50 Hz
54 F Si 25-32 61001000 M8x28 75
M M 4 L A (1)
2 4
71
14 148 115 208
0.25
230 Vac 50 Hz
M M 4 L B (1)
2 4
71
14 148 115 208
0.37
230 Vac 50 Hz
54 F Si 20-25 61000700 M6x20 19.5 M12D4000 KIT08019.011 (Gr.05) 54 F Si 20-25 61000700 M6x20 19.5 M12E4000 KIT08019.012 (Gr.1)
M M 4 M A (1)
2 4
80
19 170 126 234
0.55
230 Vac 50 Hz
M M 4 M B (1)
2 4
80
19 170 126 234
0.75
230 Vac 50 Hz
M M 4 N A (1)
2 4
90
24 185 142 247
1.10
230 Vac 50 Hz
M M 4 N B (1)
2 4
90
24 185 142 272
1.50
230 Vac 50 Hz
54 F Si 20-25 61000900 M8x21 40.4 M14H4000 KIT08019.015 (Gr.05) 54 F Si 20-25 61000900 M8x21 40.4 M14L4000 KIT08019.016 (Gr.1)
M M 4 P A (1)
2 4 100 28 210 155 310
2.20
230 Vac 50 Hz
54 F Si 25-32 61001000 M8x28 75
(•)
Power
kW
Voltage
IP IC S1
54 F Si 20-25 61000700 M6x20 19.5 M12E2000 KIT08019.011 (Gr.05) 54 F Si 20-25 61000700 M6x20 19.5 M12F2000 KIT08019.012 (Gr.1) 54 F Si 20-25 61000800 M6x20 30.4 M13G2000 KIT08019.013 (Gr.05) 54 F Si 20-25 61000800 M6x20 30.4 M13H2000 KIT08019.014 (Gr.1)
M15P2000
KIT08019.017 (Gr.05) KIT08019.018 (Gr.1)
54 F Si 20-25 61000800 M6x20 30.4 M13F4000 KIT08019.013 (Gr.05) 54 F Si 20-25 61000800 M6x20 30.4 M13G4000 KIT08019.014 (Gr.1)
VI M15N4000
KIT08019.017 (Gr.05) KIT08019.018 (Gr.1)
(•)= Approximate dimensions
AC
78
IE/FP-6AC/04-2017
®
Sect. VI - AC Motors
L2
D2
D1
H1
Adapter: supplied with the transmission kit
L1
Power range
Single Motor
Transmission kit (for pump)
Size
Adapter Screw Code UNI L2 5931
Phases Poles
D1 D2 H1 L1 Power (•) (•) (•) (•)
Cable gland metric thred
Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Version B14
M T 2 R A (1)
3 2
63
11 125 95 189
0.18
M T 2 R B (1)
3 2
63
11 125 95 189
0.25
M T 2 L A (1)
3 2
71
14 148 115 208
0.37
M T 2 L B (1)
3 2
71
14 148 115 208
0.55
M T 2 M A (1)
3 2
80
19 170 126 234
0.75
M T 2 M B (1)
3 2
80
19 170 126 234
1.10
M T 2 N A (1)
3 2
90
24 185 142 247
1.50
M T 2 N B (1)
3 2
90
24 185 142 272
2.20
230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L2000 KIT08019.015 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34N2000 KIT08019.016 (Gr.1)
M T 2 P A (1)
3 2 100 28 210 155 310
3.00
230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75
M T 2 P B (1)
3 2 112 28 225 182 325
4.00
230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75
M T 4 R A (1)
3 4
63
11 125 95 189
0.12
M T 4 R B (1)
3 4
63
11 125 95 189
0.18
230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31B4000 KIT08019.009 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C4000 KIT08019.010 (Gr.1)
M T 4 L A (1)
3 4
71
14 148 115 208
0.25
M T 4 L B (1)
3 4
71
14 148 115 208
0.37
M T 4 M A (1)
3 4
80
19 170 126 234
0.55
M T 4 M B (1)
3 4
80
19 170 126 234
0.75
M T 4 N A (1)
3 4
90
24 185 142 247
1.10
M T 4 N B (1)
3 4
90
24 185 142 272
1.50
230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34H4000 KIT08019.015 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L4000 KIT08019.016 (Gr.1)
M T 4 P A (1)
3 4 100 28 210 155 310
2.20
230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75
M35N4000
M T 4 P B (1)
3 4 100 28 210 155 310
3.00
230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75
M35P4000
3 4 112 28 225 182 325
4.00
230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75
M36Q4000
M T 4 P C (1)
kW
Voltage
IP IC S3
230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C2000 KIT08019.009 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31D2000 KIT08019.010 (Gr.1) 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E2000 KIT08019.011 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32F2000 KIT08019.012 (Gr.1) 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G2000 KIT08019.013 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33H2000 KIT08019.014 (Gr.1)
M35P2000 KIT08019.017 (Gr.05) M36Q2000 KIT08019.018 (Gr.1)
230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32D4000 KIT08019.011 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E4000 KIT08019.012 (Gr.1) 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33F4000 KIT08019.013 (Gr.05) 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G4000 KIT08019.014 (Gr.1)
KIT08019.017 (Gr.05) KIT08019.018 (Gr.1)
(•)= Approximate dimensions
IE/FP-6AC/04-2017
79
VI AC
®
Sect. VI - AC Motors 8.25 max
n°4 - Ø9
10 Ø1
Ø35
(Ø115)
118
6.40
(126)
5.32 max
(175)
118
Phases Poles Size
Power
Cable gland metric thred
Single-phase motors 2-4 Poles - 230 Vac 50Hz - Special housing Single Motor
M M 2 S A (1)
2 2 71
0.75
230 Vac 50 Hz
54 F Light-duty
20
M12GY3FF.001
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
M M 2 S B (1)
2 2 71
1.10
230 Vac 50 Hz
54 F Light-duty
20
M12HY3FF.000
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
M M 4 S C (1)
2 4 71
0.85
230 Vac 50 Hz
54 F Light-duty
20
M12YY3FF.001
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
Power range
kW
Voltage
IP IC
Service
Transmission kit
Note
IP protection level becomes effective after installationon on power pack.
8.25 max
0 Ø 11
n°4 - Ø9
VI AC
Ø35
(Ø115)
118
6.40
(117)
3.15 max
(175)
118
Phases Poles Size
Power
Cable gland metric thred
Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Direct fixing Single Motor
M T 2 S A (1)
3 2 71
0.75
230/400 Vac 50 Hz 54
F Light-duty
20
M32GY3FL.003
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
M T 2 S B (1)
3 2 71
1.10
230/400 Vac 50 Hz 54
F Light-duty
20
M32HY3FL.001
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
M T 4 S A (1)
3 4 71
0.75
230/400 Vac 50 Hz 54
F Light-duty
20
M32GY3FL.002
KIT08019.005 (for Gr.0.5 pumps) Without fan KIT08019.006 (for Gr.1 pumps)
Power range
kW
Voltage
IP IC
Service
Transmission kit
Note
IP protection level becomes effective after installationon on power pack.
80
IE/FP-6AC/04-2017
®
Sect. VI - AC Motors
n°4 - Ø9
0
Ø 11
118
9.5 max
(238)
Ø20 (Ø154)
118
7.5
n°4 - Ø9
0
(Ø154)
118
7.5
Ø 11
(126)
Without fan
Ø20
(126)
With fan
118
(203)
9.5 max
Single Motor
Phases Poles Size
Power range
Cable gland metric thred
Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Direct fixing Power
M T 2 T A (1)
3 2 80
2.7
230/400 Vac 50 Hz 44
F Light-duty 20-25 M33YD1FF.000
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps)
M T 2 T B (1)
3 2 80
2.7
230/400 Vac 50 Hz 44
F Light-duty 20-25 M33YD1FF.001
KIT08019.007 (for Gr.0.5 pumps) Without fan KIT08019.008 (for Gr.1 pumps)
M T 4 T A (1)
3 4 80
2.2
230/400 Vac 50 Hz 44
F
S3 - 4%
20-25 M33NF1FF.001
KIT08019.007 (for Gr.0.5 pumps) Without fan KIT08019.008 (for Gr.1 pumps)
M T 4 T B (1)
3 4 80
2.2
230/400 Vac 50 Hz 55
F
S3 - 4%
20-25 M33NF4FF.000
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps)
M T 4 T C (1)
3 4 80
2.2
230/400 Vac 50 Hz 44
F
S3 - 4%
20-25 M33NF1FF.000
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps)
M T 4 T D (1)
3 4 80
3.0
230/400 Vac 50 Hz 54
F Light-duty 20-25 M33PF3FF.000
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps)
Voltage
kW
IP IC
Service
Transmission kit
Note
Ø25
(150)
IP protection level becomes effective after installationon on power pack.
n°4 - Ø9
(Ø175)
Ø110 118
7.5
VI
118
(280)
9.5 max
AC
Single Motor
Phases Poles Size
Power range
Cable gland metric thred
Single-phase motors 4 Poles - 230 Vac 50Hz - Direct fixing Power
M M 4 V A (1)
2 4 90
1.8
230 Vac 50 Hz
44 F Light-duty 20-25 M14MF1FF.001
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps) Start torque 13Nm
M M 4 V B (1)
2 4 90
3.0
230 Vac 50 Hz
55 F
KIT08019.007 (for Gr.0.5 pumps) With fan KIT08019.008 (for Gr.1 pumps)
kW
Voltage
IP IC
Service
S3 - 7%
20-25 M14PF4FF.000
Transmission kit
Note
IP protection level becomes effective after installationon on power pack.
IE/FP-6AC/04-2017
81
®
Sect. VI - AC Motors M
*
*
*
*
(*) /* -
Motor orientation
Connector box position on power pack.
/1
Do not use “orientation 1” with blocks. Std
/4
/2
P
/3
VI AC
82
IE/FP-6AC/04-2017
®
Sect. VII - Transmission kit Transmission kit (only for motors on the catalog) Type End section VII Specify the transmission kit whether you requested the joint and accessories assembly (without motor).
Transmission kit Code Pump L KIT08019.000
Gr. 0.5
63.3
Ø 14
01 KIT08019.001
**
Gr. 1
46.9
Transmission kit Code Pump L KIT08019.002
Gr. 0.5
64.5
14
Ø 14
02 KIT08019.003
Gr. 1
48.2
14
For DC motors Ø
**
T ** -
GA (350 W - Ø 80 - Pag. 72) GC (700 W - Ø 80 - Pag. 72) GB (400 W - Ø 80 - Pag. 72) GD (800 W - Ø 80 - Pag. 72)
L
For DC motors AA (1500 W - Ø 115 - Pag. 73) EN (1600 W - Ø 115 - Pag. 73) AB (2000 W - Ø 115 - Pag. 73) ES (2200 W - Ø 115 - Pag. 73) GN (1600 W - Ø 115 - Pag. 74) GP (2200 W - Ø 115 - Pag. 74)
Ø
FP ........
L
** 03
Transmission kit Code Pump L KIT08019.004
Gr. 1
45.4
Ø 20
For DC motors GJ (3000 W - Ø 125 - Pag. 74) FB (3000 W - Ø 125 - Pag. 74)
Ø
32
L
28.5
Note: in ventilated motors (accessory “D” page 74 ) the transmission is included in the kit ventilation
VII
83
®
Sect. VII - Transmission kit Transmission kit (only for motors on the catalog) Type End section VII Specify the transmission kit whether you requested the joint and accessories assembly (without motor). FP ........
T ** 19.5
KIT08019.009
L1
Z
Gr. 0.5 47.1 14
30
62.7
30
42.8
1R
R KIT08019.010
Gr. 1
30.6 20
63 (B14)
Page
Ø 11
Code
For AC motors Ref. Size
Ø
**
Transmission kit Pump L Ø
L
79
L1 Z
19.5
KIT08019.011
Gr. 0.5 47.1 14
L1
Z
26.5
42
1L
L KIT08019.012
Gr. 1
30.7 20
26.5
42
71 (B14)
Page
Ø 14
Code
For AC motors Ref. Size
Ø
**
Transmission kit Pump L Ø
78
L
L1 Z
79
30.4
KIT08019.013
L1
Z
Gr. 0.5 47.1 14
38
53
1M
M KIT08019.014
Gr. 1
30.7 20
38
53
80 (B14)
Page
Ø 19
Code
For AC motors Ref. Size
Ø
**
Transmission kit Pump L Ø
78 L
L1 Z
79
40.4
KIT08019.015
Gr. 0.5 47.1 14
L1
Z
45.4
63
1N
N KIT08019.016
Gr. 1
30.7 20
45.4
63
90 (B14)
Page
Ø 24
Code
For AC motors Ref. Size
Ø
**
Transmission kit Pump L Ø
78 L
L1 Z
79
75
KIT08019.017
Gr. 0.5 62.9 14/20 57
81.5 P
1P KIT08019.018
**
VII
Gr. 1
46.6 20
57
81.5
Code
Transmission kit Pump
L
Ø
KIT08019.005
Gr. 0.5
64.5
14
**
KIT08019.006
Gr. 1
48.2
14
Code
Transmission kit Pump
L
Ø
KIT08019.007
Gr. 0.5
68
14
KIT08019.008
Gr. 1
51.7
“Z” : dimension of the coupling side motor
20
71 (direct fixing)
For AC motors Ref. Size T V
1T
84
For AC motors Ref. Size S
1S
100-112 (B14)
80-90 (direct fixing)
Page
Ø 28
Z
Ø
L1
78 L
L1 Z
79
Page Ø
Code
For AC motors Ref. Size
80
L
Page Ø
**
Transmission kit Pump L Ø
81
L
®
Sect. VIII - Blocks and CETOP valves Standard blocks Mounting position Accessory Separation line
In the order confirmation the code of the “Blocks and CETOP valves” will be converted into a type Jxxxx (xxxx = sequential number).
FP ...
J
*
The blocks mounting kit (interface 90°, heighten) is included on the selection code (see “Mounting kits “table page 88).
(00) -
Blocks mounting on horizontal power pack
95
4 3 2 1
Blocks orthogonal to the axis Except AC motors ref. size M-N-P
J B
4 3 2 1
(V60403004)
Blocks orthogonal to the axis with heighten For AC motors ref. size M-N-P
J C
(V60403005) 4 3
(V60403005)
136.5
J A
108.5
J 0
2 1
4 3
2 1
Blocks parallel to the axis with interface 90° Except AC motors ref. size P
(V60403004)
Blocks parallel to the axis with heighten and interface 90° For AC motors ref. size P
The blocks can not be mounted with motors oriented in position “1” (DC motors, see page 76. AC motors, see page 82).
Blocks mounting on vertical power pack J 0
J A
J B
J C
136.5
108.5
95
4 3 2 1
4 3 2 1 1 2
3 4
(V60403004)
4
3 4
(V60403005)
2
1 2
(V60403005) (V60403004)
VIII Blocks orthogonal to the axis Except AC motors ref. size M-N-P
Blocks orthogonal to the axis with heighten For AC motors ref. size M-N-P
Blocks parallel to the axis with interface 90° Except AC motors ref. size P
Blocks parallel to the axis with heighten and interface 90° For AC motors ref. size P
The blocks can not be mounted with motors oriented in position “1” - DC motors, see page 76. AC motors, see page 82.
IE/FP-8/03-2017
85
®
Sect. VIII - Blocks and CETOP valves Block type Accessory Pressure relief valve setting on “A” line Pressure relief valve setting on “B”line CETOP valve End section VIII
FP ..J*(00)
**
(00)
(..)
(..)
/***/ -
Repeat for each block (max.5)
** (00)
(..)
(..)
(00)
(..)
(..)
**
/***/ - Block type
Description
Code
Drawing 55
(00)
(0)
(0)
Middle parallel - Lateral ports G3/8”
V60403010
P1
A
49
A2
80
T1
.5
A
(0)
(0)
Middle parallel - Rear ports G3/8”
B
P1
V60403001
T1 B
P
T
P1
T1
49
(00)
P1 A
B
39
A3
Scheme
T1
80
T1
55
(00)
(0)
(0)
Middle series - Lateral ports G3/8”
V60403011
A
49
B2
P1
80
T1
.5
A
39
(00)
(0)
(0)
Middle series - Rear ports G3/8”
P1
V60403003
B
B
P
T
P1
T1
49
B3
A
B
80
E1
(00)
(0)
(0)
With pilot check valve on ”A” port . Rear ports G1/4”
A
55
(00)
(0)
(0)
With pilot check valve on ”B” port. Rear ports G1/4”
V60413003
E3
(00)
(0)
(0)
With pilot check valve on ”A” and “B” ports. Rear ports G1/4”
P1
P
T
P1
T1
A
A 80
VIII
T1
B
49
E2
B
V60413002
B P
T
P1
T1
A
B
V60413001 P
T
P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012) 86
IE/FP-8/03-2017
®
Sect. VIII - Blocks and CETOP valves /***/ - Block type
(00)
(..)
(..)
Description
(A)
(0)
With pressure relief valve on “A” port Setting max. 70 bar - Rear ports G1/4”
**
F1
F2
F3
(00)
(00)
(00)
Code V60413004
.5
69
(B)
(0)
With pressure relief valve on “A” port Setting max. 160 bar - Rear ports G1/4”
(C)
(0)
With pressure relief valve on “A” port Setting max. 330 bar - Rear ports G1/4”
V60413010
(0)
(A)
With pressure relief valve on “B” port Setting max. 70 bar - Rear ports G1/4”
V60413005
V60413007
With pressure relief valve on “B” port Setting max. 160 bar - Rear ports G1/4”
V60413008
(0)
(C)
With pressure relief valve on “B” port Setting max. 330 bar - Rear ports G1/4”
V60413011
(A)
(A)
With pressure relief valve on “A” and “B” Setting max. 70 bar - Rear ports G1/4”
V60413006
(B)
With pressure relief valve on “A” and “B” Setting max. 160 bar - Rear ports G1/4”
V60413009
(C)
With pressure relief valve on “A” and “B” Setting max. 330 bar - Rear ports G1/4”
.5
T1
A
B
T1 P1
A 80
.5
69
B
P
T
P1
T1
A
B
T1 P1
B
P
T
P1
T1
A
A 80
(C)
P1 P1
A
69
(B)
Scheme
T1
80
(0)
(B)
Drawing
49
(..)
49
(..)
V60413012
B
49
** (00)
B
P
T
P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012)
VIII
IE/FP-8/03-2017
87
®
Sect. VIII - Blocks and CETOP valves Mounting kits Mounting kit: blocks
For No. blocks
Code
1
V60513007
2
V60513008
3
V60513009
4
V60513010
1
V60513011
2
V60513012
3
V60513013
4
V60513014
Mounting position 0-2-3
Mounting position 1 (with heighten)
Mounting kit: interface 90°
Code V60513051
Mounting position 2 Mounting kit: interface 90° with heighten
Code V60513049
Mounting position 3
The blocks mounting kit (interface 90°, heighten) is included on the selection code (see mounting position, page 85).
connectors supplied with the valve (1)
** (00)
(..)
/***/
(..)
/***/ - CETOP 3 valves
Voltage
Spool (2) Type
24 VDC (M)
Screw kit for valve mounting
Scheme
ADC3E01CM001 01
/002/
12 VDC (L)
ADC3E01CL001
/003/
24 VDC (M)
ADC3E02CM001 02
/004/
Mounting
Without valve
/000/ /001/
Code
12 VDC (L)
a
C
C
a
ADC3E02CL001
A
B
P
T
A
B
P
T
b
b
V60513015 /005/
24 VDC (M)
ADC3E03CM001
/006/
12 VDC (L)
ADC3E03CL001
/007/
24 VDC (M)
ADC3E04CM001
/008/
12 VDC (L)
ADC3E04CL001
03
VIII
04
C
C
a
a
A
B
P
T
A
B
P
T
b
b
1 = Valves supplied with connector. Without connector see accessories page 89 2 = More details, features and performances, see catalog “Valves and Electronics” code DOC00078
88
IE/FP-8/03-2017
®
Sect. IX - Accessories Accessories (optional) First accessory Second accessory
*
R
*
*
Description
Drawing 124
A
B
C
Code
124
Standard foot, (galvanized sheet steel) thickness 2.5 mm (unassembled)
Kit (foot and screws): 17010075
n°4 Ø 9,5
Non-removable red plastic plug for pressure relief valve (unassembled)
Tanks compatible (except for orientation / 3) S**A S**B S**C S**G S**L
Plug: 60309200
Kit (protectin, nut, tierods, washers): 17010048
Protection device for DC motors (supplied assembled)
For motors: M2EN M4ES With blocks, please add the block code V60403004
All motors are compatible except orientation / 3
120
48
125
D
Note All motors are compatible except orientation / 3
45,5
FP ........
High foot, (galvanized sheet steel) thickness 2 mm (unassembled)
Kit (foot and screws): 17010053
n°4 Ø 9
Tanks compatible (except for orientation / 3) S**A S**B S**C S**D S**F S**G S**L
101.6
Collar in welded sheet steel, thickness 2 mm (unassembled)
4 FORI M6
Collar: 25000300 Ø 121
E
11 4
101.6
Ø
Tank fixing kit (screws and O-Ring): 17010080
26
IX F
Without valves connectors
IE/FP-9/03-2017
89
®
Examples Examples with FPA endhead A
5
B
A
B
FPA 0 B1 2DAAA+B 5TG -03 -
5TG
Cavity -
2
2DAAA
+B
1
1 B
2 7
7
6
5
6
6-7 A-B -
A A
B
5TG
Cavity -
2
1
2DAAA +*
1
2
B(170)
5
7
6
6
7C
6
7 A-B -
A
B
A
B
5TG
Cavity
2DAAA
1
1 B
2 5
7
7
6C
6
6 7 A-B -
90
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw B1 and detachable closing, standard setting 150 bar Piloted solenoid valve normally clo2DAAA sed, without emergency. Voltage 12 +B VDC + Flow control valve 1.4 l/min 5TG Plug Not specified, return lines 6 and 7 open Combinations plugs on ports -03 (A= open; B= with plug) End section -
Code
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check B1(90) valve with screw and detachable closing, special setting 90 bar Piloted solenoid valve normally 2DAAA closed, without emergency. Voltage 12 VDC 5TG Plug + Flow control valve 1.4 l/min +B Not specified, return line 6 open Flow control valve on return 7, flow 7C 2.1 l/min Combinations plugs on ports -00 (A,B= open) End section -
FPA 0 B1 2DAAA 5TG 6C -03 -
5
-
2
Code
FPA 0 B1(90) 2DAAA 5TG+B 7C -01 -
5
B
..
Code
Page 13
14
16 18 — 20 —
.. Page 13 14
16 18 — 19 20 —
..
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw B1 and detachable closing, standard setting 150 bar Piloted solenoid valve normally 2DAAA closed, without emergency. Voltage 12 VDC 5TG Plug Flow control valve on return 6, flow 6C 2.1 l/min Not specified, return line 7 open Combinations plugs on ports -03 (A= open ; B= with plug) End section -
Page 13
14
16 18 19 — 20 —
®
Examples Examples with FPC endhead
FPC 0 B1 2DAAA 3TE 4TK 5TG+B 7C 9C -01 - ..
A
2
5
B
A
B
C
Cavity
C
5TG
2DAAA
3TE
3
+B
4TK
B
4 G 1/4 8
7 7C
1
6
6
9C
8
9
Code
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 1 B1 and detachable closing, standard setting 150 bar Piloted solenoid valve normally 2 2DAAA closed, without emergency. Voltage 12 VDC 3 3TE Plug 4 4TK Plug (union G1/4) 5TG Plug + Flow control valve 1.4 l/min 5 +B 6 Not specified, return line 6 open 7 Flow control valve 2.1 l/min 7C 8 Not specified, return line 8 open 9 Flow control valve 2.1 l/min 9C Combinations plugs on ports A-B-C -01 (A-B-C= open) End section -
Page 13
21
23 27 30 31 — 32 — 32 33 —
FPC 0 B1(90) 2DAAA 3TC+B 4HA 5TH 8C -05 - ..
A
2
5
B
A
C
Cavity
5TH
2DAAA
+E
3TC
3 4HA
B(170)
4
7
8C
8
7
6
1
6 9
9
Code
Description Page Thread ports P-T G1/4” 13 0 (blocks interface) Pressure relief valve with check 1 21 B1(90) valve with screw and detachable closing, special setting 90 bar Piloted solenoid valve normally 2 23 2DAAA closed, without emergency. Voltage 12 VDC 3TG 3 Plug + Flow control valve 1.4 l/min 27 +B 4 30 4HA Push-button control 5 31 5TH Plug 6-7 Not specified, return lines 6 and 7 open — 8 Flow control valve 2.1 l/min 32 8C 9 Not specified, return 9 open — Combinations plugs on ports A-B-C 33 -05 (A = open; B-C= with plug) End section — -
91
®
Examples
FPC 0 B1 2TD 3TE 4DAAAA 5TH 7C 8C 9C -01 - ..
A
2
5
B
A
B
C
Cavity
C
5TH
2TD
3TE
3 G 1/4 4DAAA
B
4
7 8C
6
6
7C
1 9 9C
8
9
Code
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 1 B1 and detachable closing, standard setting 150 bar 2 2TD Plug (union G1/4) 3 3TE Plug Piloted solenoid valve normally 4 4DAAAA closed, without emergency. Voltage 12 VDC 5 5TH Plug 6 Not specified, return line 6 open 7 Flow control valve 2.1 l/min 7C 8 Flow control valve 2.1 l/min 8C 9 Flow control valve 2.1 l/min 9C Combinations plugs on ports A-B-C -01 (A-B-C= open) End section -
FPC 0 B1 2TC 3DDAA 4ZA 5TH 9C
A
2
5
B
A
C
5TH
2TC
3DDAA
3 4ZA
B
4 8
8
92
Cavity
C
7
7
6
1
6 9C
9
Code
Page 13
21 24 26 29 31 — 32 32 32 33 —
-06 - ..
Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 1 B1 and detachable closing, standard setting 150 bar 2 2TC Plug Piloted solenoid valve normally 3 3DDAA closed, with emergency. Voltage 12 VDC 4 4ZA Hand pump displacement 1cc 5 5TH Plug 6-7-8 Not specified, return lines 6 - 7 - 8 open 9 Flow control valve 2.1 l/min 9C Combinations plugs on ports A-B-C -05 (A = open; B-C= with plug) End section -
Page 13
21 24 26 30 31 32 33 —
®
Examples Examples with FPL endhead FPL 0 B1 2DAAA 3DDAA 4DAAA 8C -04 - ..
A
B
A
2
B
D D
C
Cavity
C
2DDAA
3DDAA
3 4DAAA
B
1
4 8C
7
8
7
Code Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 1 B1 and detachable closing, standard setting 150 bar Direct operated solenoid valve 2 2DDAA normally closed, with emergency Voltage 12 VDC Direct operated solenoid valve 3 3DDAA normally closed, with emergency Voltage 12 VDC Piloted solenoid valve normally 4 4DAAA closed, without emergency. Voltage 12 VDC 7 Not specified, return line 7 open 8 8C Flow control valve 2.1 l/min Combinations plugs on ports A-B-C-D -04 (A-B-C= open; D= with plug) End section -
Page 13
34
36
39
42 — 44 45 —
FPL 0 B1(100) 2DAAA 3DDAA 4TE -00 - ..
A
B
A
2
B
D D
C
Cavity
C
2DDAA
3DDAA
3 4TE
B
4 8
8
7
7
1
Code Description Thread ports P-T G1/4” 0 (blocks interface) Pressure relief valve with check 1 B1(100) valve with screw and detachable closing, special setting 100 bar Direct operated solenoid valve 2 2DDAA normally closed, with emergency Voltage 12 VDC Direct operated solenoid valve 3 3DDAA normally closed, with emergency Voltage 12 VDC 4 4TE Plug 7-8 Not specified, return lines 7-8 open Combinations plugs on ports A-B-C-D -00 (A-C = open; B-D= with plug) End section -
Page 13 34
36
39 43 — 45 —
93
®
Examples Examples with FPE endhead
A
B
A
C
D
FPE 0 B1 2D(1A)AA 3TC+B -04 -
B
Cavity -
+B
2
22D(1A)AA
2
3TC
3
4
S2
S1 3
1
1
1B
1
2
9
3
9
A
B
A
9 A-B C-D -
Code
Description Page Thread ports P-T G1/4” 13 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 46 B1 and detachable closing, standard setting 150 bar Directional control valve 4 way 3 48 2D(1A)AA positions with emergency. Voltage 12 Vdc (closed centre “C” spool) 3TC Plug + Flow control valve 1.4 l/min 50 +B Not specified, return 9 open — — Combinations plugs on ports 52 -04 (A-B= with protection; C-D= with plug) End section — -
C
D
B
FPE B1 2D(1A)AA 3TC+B -04 Cavity 3TC
2
2D(2A)AA
2
4
3
1
3
-
1
1B
1 2
9C
9
94
..
3 9 A-B C-D -
Code
..
Description Page Thread ports P-T G1/4” 13 0 (blocks interface) Pressure relief valve with check valve (65 ÷ 180 bar) with screw 46 B1 and detachable closing, standard setting 150 bar Directional control valve 4 way 2 po48 2D(2A)AA sitions without emergency. Voltage 12 Vdc (closed centre “C” spool) Plug 50 3TC Flow control valve 2.1 l/min 51 9C Combinations plugs on ports 52 -04 (A-B= with protection; C-D= with plug) End section — -
Note
®
95
Note
96
®
®
Code DOC00038 - Rev. 08
Dana Brevini S.p.A. Via Luciano Brevini 1/a 42124 Reggio Emilia Tel. +39 0522 270711 Fax +39 0522 270660 www.dana.com/brevini info@brevinifluidpower.com