EHC Mercury Series Radiators for plumbed heating systems

Fitting instructions

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

The Electric Heating Company Ltd Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow, G72 0UP Tel. 01698 820533 [email protected] Fax. 01698 825697 www.electric-heatingcompany.co.uk

CONTENTS 1. 2. 3. 4. 5. 6. 7 8 9. 10. 11.

1.

Introduction………………………………………………….2 Storage………………………………………………………2 Unpacking the Unit………………………………………..2 Package contents ........................................................ 3 Fitting the Radiator - Mounting...................................... 4 Fitting the Radiator – Valve Connections………………. 7 Commisioning – Balancing the System………………… 9 Commisisoning – Fitting TRV……………………………. 9 Technical Specification ................................................. 10 Care Instructions ......................................................... 13 Guarantee ................................................................... 13

Introduction The Mercury range of radiators from The Electric Heating Company are specially designed to provide fast and economical heat when used in conjunction with electric and conventional boilers. An Aluminium outercase conceals an internal copper pipe heat exchanger which transfers heat to the radiator culminating in a high performance and energy saving heater Each radiator comes with an in-built thermostat valve body that is controlled by the TRV supplied The mercury radiators can be installed as part of an Electric Wet central heating System and as such such we recommend our award winning fusion boiler

2.

Storage_______________________________________ Mercury radiators should be stored in their original packaging in an upright position in an area free from changing enviromental conditions such as damp and frost.

3.

Unpacking the Unit_____________________________

Remove the unit and its part from the box carefully. Check all parts on page 3 are present before procedding to installation EHC Neptune Unvented Cylinders – Installation and technical manual

Page 2

4.

Package contents

Fixings

Install Manual

Brackets x 2

Valve System

Radiator x 1

TRV

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 3

5.

Fitting Radiator - Mounting

h

h

H

1. Mark and drill the holes in the wall according to the sizes in the table below. Fixings for solid walls are supplied, however use appropriate fixings for non solid walls

Radiator Size Standard

Low profile

2.

Bracket Placement

Width 400 600 800 1200 1400 1600

Height 600 600 600 600 600 600

H 527 527 527 527 527 527

h 427 427 427 427 427 427

w 290 490 690 1090 1290 1490

l 180 180 180 180 180 180

1000 1400 1800

300 300 300

167 167 167

67 67 67

890 1290 1690

180 180 180

Screw the brackets to the wall, spring end to the top as in the diagram above. Ensure that a spirit level is used to guarantee that the brackets are perpindicular .

5.

Fitting Radiator - Mounting

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 4

3.

Lift the radiator onto the brackets, engaging the brackets’ spring-loaded hooks into the top of the radiato

Ensure that the radiator is perpendicular to the brackets. See Diagram below

CORRECT

INCORRECT

Incorrect positioning of the radiator with respect to the spring clip on the bracket may lead to radiator damage

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 5

5.

Fitting Radiator - Mounting

Radiator should be mounted horizontally only

4. Once the is hooked on to the top of the bracket rotate the radiator towards the mounting surface slowly. Once the radiator is vertical and touching the bottom edge of the mounting bracket, lift the raditor slighly so that bottom edge clicks on the bottom edge of the mounting bracket. Repeat this for the other bracket

________________________________________________________________________________________________

5. Screw heater vent in. 6. If it is necessary to remove the radiator lift the radiator vertically until the bottom edge clears the bottom of the mounting bracket.. Rotate away from brackets (approx 15 degs) then lift off the spring clips on the top of the bracket

6.

Fitting Radiator – Vertical Valve Connections

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 6

Vertical Pipe Option Radiator Pipework connections

Radiator connections

½”

Reducer X 2 NOTE : MUST BE USED AND TIGHTENED WITN ALLAN KEY

Valve Body

Connctions to system pipe work

¾” Pipe X

6.

Fitting Radiator – Angled Connections

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 7

Angled Pipe Option Radiator Pipework connections

Radiator connections

½”

Reducer X 2 NOTE : MUST BE USED AND TIGHTENED WITN ALLAN KEY

Valve Body

Connctions to system pipe work

X

7.

Commisioning - Balancing the system_____________

Once all the radiators in the system have been fitted, use the balancing nipple (B) to EHC Neptune Unvented Cylinders – Installation and technical manual

Page 8

balance the complete system if required.

7

45

6

8.

Commisioning – Fitting TRV______________

Once the radiator is mounted securely and system has been balanced remove the TRV from its packaging and screw into position

9.

Technical Specification_- Radiator___________________

General External Material

-

Alluminium

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 9

Heat conductor

-

Aluminium

Internal Horizontal Pipwork Internal Vertical Pipework

-

Copper DIN 15 Copper DIN 20

Pipe connections

-

1/2“ internal

System specifations Size

85/75/20

75/65/20

Standard 400 x 600 x 90 600 x 600 x 90 800 x 600 x 90 1000 x 600 x 90 1200 x 600 x 90 1400 x 600 x 90 1600 x 600 x 90

Rating Watts 575 1109 1599 2125 2712 3336 3948

Rating Watts 1962 3784 5456 7251 9253 11382 13471

Rating Watts 479 922 1331 1769 2257 2777 3287

Low Profile 1000 x 300 x 90 1400 x 300 x 90 1800 x 300 x 90

1122 1721 2341

3828 5872 7987

935 1432 1948

EHC Neptune Unvented Cylinders – Installation and technical manual

Water Dry Capacity weight Rating Watts (litres) (kg) 1634 0,52 3.9 3146 0.68 5.5 4541 0.84 7.1 6036 1.04 8.8 7701 1.14 10.4 9475 1.37 11.3 11215 1.51 13.4

3190 4886 6647

0.54 0.72 0.91

4.9 6.6 8.4

Page 10

9. Technical Specification______________________________ TRV

General Sensor filled with Liquid Connection Nut made from Nickel-plated Brass Equipped with easy to use temeperature limiting tabs

Specification Thermostat connection

-

M30 x 1.5

Setpoint range

-

1-5

Temperature Range

-

0 to 28 deg C

Closing Dimension

-

9.5mm

Note: Zero – position is also thermostatically controlled when temperature falls TRV may open

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 11

9.

Technical Specification______________________________ Valve Connection

General Hot-Forgedc Brass Body Brass nickel ball valve insert EPDM o-ring sealings Brass union connections Brass radiator Connection nuts Seat sealings PTFE EPDM seals

Specifiaction Medium

-

Water

Ph-value

-

8...9.5

Operating temperature -

-

max 120 deg c

Operating pressure

-

max 10 bar

Kv valaue

-

3.5( straight) 1.8 ( angled)

Pip connection

-

¾“ External

Radiator connection

-

½“ External

DN

-

15

EHC Neptune Unvented Cylinders – Installation and technical manual

Page 12

10.

Care instructions_____________________________

Mercury radiators can be cleaned with water and mild detergent. Avoid abrasive cleaning equipment and agents, and solvent-based cleaners.

11.

Guarantee Mercury radiators carry a 15 year guarantee against faulty materials or manufacture provided that: 







It has not been subjected to frost damage



The guarantee period starts from the date of purchase and no registration is required

It has not been modified in any way, other than by the manufacturer



The extended guarantee is not transferable, and rests with the original householder.

It has not been misused, tampered with or subjected to neglect.



The system is fed from a public water supply.

It has been correctly installed as per this document and all the relevant standards, regulations and codes of practice in force at the time

EXCLUSIONS – THE GUARANTEE DOES NOT COVER the effects of scale build up, any labour charges associated with replacing the unit or its parts, nor any consequential losses caused by the failure or malfunction of the unit.